TY - JOUR A1 - Jablonski, Melanie A1 - Münstermann, Felix A1 - Nork, Jasmina A1 - Molinnus, Denise A1 - Muschallik, Lukas A1 - Bongaerts, Johannes A1 - Wagner, Torsten A1 - Keusgen, Michael A1 - Siegert, Petra A1 - Schöning, Michael Josef T1 - Capacitive field‐effect biosensor applied for the detection of acetoin in alcoholic beverages and fermentation broths JF - physica status solidi (a) applications and materials science N2 - An acetoin biosensor based on a capacitive electrolyte–insulator–semiconductor (EIS) structure modified with the enzyme acetoin reductase, also known as butane-2,3-diol dehydrogenase (Bacillus clausii DSM 8716ᵀ), is applied for acetoin detection in beer, red wine, and fermentation broth samples for the first time. The EIS sensor consists of an Al/p-Si/SiO₂/Ta₂O₅ layer structure with immobilized acetoin reductase on top of the Ta₂O₅ transducer layer by means of crosslinking via glutaraldehyde. The unmodified and enzyme-modified sensors are electrochemically characterized by means of leakage current, capacitance–voltage, and constant capacitance methods, respectively. KW - acetoin KW - acetoin reductase KW - alcoholic beverages KW - biosensors KW - capacitive field-effect sensors Y1 - 2021 U6 - http://dx.doi.org/10.1002/pssa.202000765 SN - 1862-6319 VL - 218 IS - 13 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Niedermeier, Jana A1 - Penner, Crystal A1 - Usherovich, Samuel A1 - Bélanger-Champagne, Camille A1 - Paulßen, Elisabeth A1 - Cornelia, Hoehr T1 - Optical Fibers as Dosimeter Detectors for Mixed Proton/Neutron Fields - A Biological Dosimeter JF - electronics N2 - In recent years, proton therapy has gained importance as a cancer treatment modality due to its conformality with the tumor and the sparing of healthy tissue. However, in the interaction of the protons with the beam line elements and patient tissues, potentially harmful secondary neutrons are always generated. To ensure that this neutron dose is as low as possible, treatment plans could be created to also account for and minimize the neutron dose. To monitor such a treatment plan, a compact, easy to use, and inexpensive dosimeter must be developed that not only measures the physical dose, but which can also distinguish between proton and neutron contributions. To that end, plastic optical fibers with scintillation materials (Gd₂O₂S:Tb, Gd₂O₂S:Eu, and YVO₄:Eu) were irradiated with protons and neutrons. It was confirmed that sensors with different scintillation materials have different sensitivities to protons and neutrons. A combination of these three scintillators can be used to build a detector array to create a biological dosimeter. KW - biological dosimeter KW - Bragg peak KW - relative dosimetry KW - optical fibers KW - proton therapy KW - protons KW - neutrons Y1 - 2023 U6 - http://dx.doi.org/10.3390/electronics12020324 SN - 2079-9292 N1 - This article belongs to the Special Issue "Applications of Optical Fiber Sensors" VL - 12 IS - 2 PB - MDPI CY - Basel ER - TY - JOUR A1 - Penner, Crystal A1 - Usherovich, Samuel A1 - Niedermeier, Jana A1 - Bélanger-Champagne, Camille A1 - Trinczek, Michael A1 - Paulßen, Elisabeth A1 - Hoehr, Cornelia T1 - Organic Scintillator-Fibre Sensors for Proton Therapy Dosimetry: SCSF-3HF and EJ-260 JF - electronics N2 - In proton therapy, the dose from secondary neutrons to the patient can contribute to side effects and the creation of secondary cancer. A simple and fast detection system to distinguish between dose from protons and neutrons both in pretreatment verification as well as potentially in vivo monitoring is needed to minimize dose from secondary neutrons. Two 3 mm long, 1 mm diameter organic scintillators were tested for candidacy to be used in a proton–neutron discrimination detector. The SCSF-3HF (1500) scintillating fibre (Kuraray Co. Chiyoda-ku, Tokyo, Japan) and EJ-260 plastic scintillator (Eljen Technology, Sweetwater, TX, USA) were irradiated at the TRIUMF Neutron Facility and the Proton Therapy Research Centre. In the proton beam, we compared the raw Bragg peak and spread-out Bragg peak response to the industry standard Markus chamber detector. Both scintillator sensors exhibited quenching at high LET in the Bragg peak, presenting a peak-to-entrance ratio of 2.59 for the EJ-260 and 2.63 for the SCSF-3HF fibre, compared to 3.70 for the Markus chamber. The SCSF-3HF sensor demonstrated 1.3 times the sensitivity to protons and 3 times the sensitivity to neutrons as compared to the EJ-260 sensor. Combined with our equations relating neutron and proton contributions to dose during proton irradiations, and the application of Birks’ quenching correction, these fibres provide valid candidates for inexpensive and replicable proton-neutron discrimination detectors Y1 - 2022 U6 - http://dx.doi.org/10.3390/electronics12010011 SN - 2079-9292 N1 - This article belongs to the Special Issue "Applications of Optical Fiber Sensors" VL - 12 IS - 1 PB - MDPI CY - Basel ER - TY - JOUR A1 - Haeger, Gerrit A1 - Grankin, Alina A1 - Wagner, Michaela T1 - Construction of an Aspergillus oryzae triple amylase deletion mutant as a chassis to evaluate industrially relevant amylases using multiplex CRISPR/Cas9 editing technology JF - Applied Research N2 - Aspergillus oryzae is an industrially relevant organism for the secretory production of heterologous enzymes, especially amylases. The activities of potential heterologous amylases, however, cannot be quantified directly from the supernatant due to the high background activity of native α-amylase. This activity is caused by the gene products of amyA, amyB, and amyC. In this study, an in vitro CRISPR/Cas9 system was established in A. oryzae to delete these genes simultaneously. First, pyrG of A. oryzae NSAR1 was mutated by exploiting NHEJ to generate a counter-selection marker. Next, all amylase genes were deleted simultaneously by co-transforming a repair template carrying pyrG of Aspergillus nidulans and flanking sequences of amylase gene loci. The rate of obtained triple knock-outs was 47%. We showed that triple knockouts do not retain any amylase activity in the supernatant. The established in vitro CRISPR/Cas9 system was used to achieve sequence-specific knock-in of target genes. The system was intended to incorporate a single copy of the gene of interest into the desired host for the development of screening methods. Therefore, an integration cassette for the heterologous Fpi amylase was designed to specifically target the amyB locus. The site-specific integration rate of the plasmid was 78%, with exceptional additional integrations. Integration frequency was assessed via qPCR and directly correlated with heterologous amylase activity. Hence, we could compare the efficiency between two different signal peptides. In summary, we present a strategy to exploit CRISPR/Cas9 for gene mutation, multiplex knock-out, and the targeted knock-in of an expression cassette in A. oryzae. Our system provides straightforward strain engineering and paves the way for development of fungal screening systems. KW - aspergillus KW - CRISPR/Cas9 KW - filamentous fungi KW - genome engineering Y1 - 2023 U6 - http://dx.doi.org/10.1002/appl.202200106 SN - 2702-4288 IS - Early View SP - 1 EP - 15 PB - Wiley-VCH ER - TY - JOUR A1 - Hoffstadt, Kevin A1 - Nikolausz, Marcell A1 - Krafft, Simone A1 - Bonatelli, Maria A1 - Kumar, Vivekanantha A1 - Harms, Hauke A1 - Kuperjans, Isabel T1 - Optimization of the ex situ biomethanation of hydrogen and carbon dioxide in a novel meandering plug flow reactor: start-up phase and flexible operation JF - Bioengineering KW - methanation KW - plug flow reactor KW - bubble column KW - biomethane KW - P2G Y1 - 2024 U6 - http://dx.doi.org/10.3390/bioengineering11020165 SN - 2306-5354 VL - 11 IS - 2 PB - MDPI CY - Basel ER - TY - JOUR A1 - Block, Franziska A1 - May, Alexander A1 - Wetzel, Katharina A1 - Adels, Klaudia A1 - Elbers, Gereon A1 - Schulze, Margit A1 - Monakhova, Yulia T1 - What is the best spectroscopic method for simultaneous analysis of organic acids and (poly)saccharides in biological matrices: Example of Aloe vera extracts? JF - Talanta Open N2 - Several species of (poly)saccharides and organic acids can be found often simultaneously in various biological matrices, e.g., fruits, plant materials, and biological fluids. The analysis of such matrices sometimes represents a challenging task. Using Aloe vera (A. vera) plant materials as an example, the performance of several spectro-scopic methods (80 MHz benchtop NMR, NIR, ATR-FTIR and UV–vis) for the simultaneous analysis of quality parameters of this plant material was compared. The determined parameters include (poly)saccharides such as aloverose, fructose and glucose as well as organic acids (malic, lactic, citric, isocitric, acetic, fumaric, benzoic and sorbic acids). 500 MHz NMR and high-performance liquid chromatography (HPLC) were used as the reference methods. UV–vis data can be used only for identification of added preservatives (benzoic and sorbic acids) and drying agent (maltodextrin) and semiquantitative analysis of malic acid. NIR and MIR spectroscopies combined with multivariate regression can deliver more informative overview of A. vera extracts being able to additionally quantify glucose, aloverose, citric, isocitric, malic, lactic acids and fructose. Low-field NMR measurements can be used for the quantification of aloverose, glucose, malic, lactic, acetic, and benzoic acids. The benchtop NMR method was successfully validated in terms of robustness, stability, precision, reproducibility and limit of detection (LOD) and quantification (LOQ), respectively. All spectroscopic techniques are useful for the screening of (poly)saccharides and organic acids in plant extracts and should be applied according to its availability as well as information and confidence required for the specific analytical goal. Benchtop NMR spectroscopy seems to be the most feasible solution for quality control of A. vera products. KW - Spectroscopy KW - (Poly)saccharides KW - Organic acids KW - Aloe vera KW - qNMR Y1 - 2023 U6 - http://dx.doi.org/10.1016/j.talo.2023.100220 SN - 2666-8319 VL - 7 IS - Art. No. 100220 SP - 1 EP - 9 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Trapp, Svenja A1 - Lammers, Tom A1 - Engudar, Gokce A1 - Hoehr, Cornelia A1 - Denkova, Antonia G. A1 - Paulßen, Elisabeth A1 - de Kruijff, Robin M. T1 - Membrane-based microfluidic solvent extraction of Ga-68 from aqueous Zn solutions: towards an automated cyclotron production loop JF - EJNMMI Radiopharmacy and Chemistry KW - Microfluidic solvent extraction KW - Ga-68 KW - Cyclotron production KW - Medical radionuclide production KW - Metal contaminants Y1 - 2023 U6 - http://dx.doi.org/10.1186/s41181-023-00195-2 SN - 2365-421X VL - 2023 IS - 8, Article number: 9 SP - 1 EP - 14 PB - Springer Nature ER - TY - JOUR A1 - Falkenberg, Fabian A1 - Voß, Leonie A1 - Bott, Michael A1 - Bongaerts, Johannes A1 - Siegert, Petra T1 - New robust subtilisins from halotolerant and halophilic Bacillaceae JF - Applied Microbiology and Biotechnology N2 - The aim of the present study was the characterisation of three true subtilisins and one phylogenetically intermediate subtilisin from halotolerant and halophilic microorganisms. Considering the currently growing enzyme market for efficient and novel biocatalysts, data mining is a promising source for novel, as yet uncharacterised enzymes, especially from halophilic or halotolerant Bacillaceae, which offer great potential to meet industrial needs. Both halophilic bacteria Pontibacillus marinus DSM 16465ᵀ and Alkalibacillus haloalkaliphilus DSM 5271ᵀ and both halotolerant bacteria Metabacillus indicus DSM 16189 and Litchfieldia alkalitelluris DSM 16976ᵀ served as a source for the four new subtilisins SPPM, SPAH, SPMI and SPLA. The protease genes were cloned and expressed in Bacillus subtilis DB104. Purification to apparent homogeneity was achieved by ethanol precipitation, desalting and ion-exchange chromatography. Enzyme activity could be observed between pH 5.0–12.0 with an optimum for SPPM, SPMI and SPLA around pH 9.0 and for SPAH at pH 10.0. The optimal temperature for SPMI and SPLA was 70 °C and for SPPM and SPAH 55 °C and 50 °C, respectively. All proteases showed high stability towards 5% (w/v) SDS and were active even at NaCl concentrations of 5 M. The four proteases demonstrate potential for future biotechnological applications. KW - Biotechnological application KW - Bacillaceae KW - Subtilisin KW - Subtilases KW - Halotolerant protease Y1 - 2023 U6 - http://dx.doi.org/10.1007/s00253-023-12553-w SN - 1432-0614 N1 - Corresponding author: Petra Siegert VL - 107 SP - 3939 EP - 3954 PB - Springer Nature CY - Berlin ER - TY - INPR A1 - Greiner, Lasse A1 - Jeromin, Günter Erich A1 - Sithole, Patience A1 - Petersen, Soenke T1 - Preprint: Studies on the enzymatic reduction of levulinic acid using Chiralidon-R and Chiralidon-S T2 - ChemRxiv N2 - The enzymatic reduction of levulinic acid by the chiral catalysts Chiralidon-R and Chiralidon-S which are commercially available superabsorbed alcohol dehydrogenases is described. The Chiralidon®-R/S reduces the levulinic acid to the (R,S)-4-hydroxy valeric acid and the (R)- or (S)- gamma-valerolactone. KW - Levulinic acid KW - Chiralidon-R KW - Chiralidon-S KW - 4-hydroxy valeric acid KW - (R)- or (S)- gamma-valerolactone Y1 - 2023 U6 - http://dx.doi.org/10.26434/chemrxiv-2023-jlvcv ER - TY - JOUR A1 - Adels, Klaudia A1 - Elbers, Gereon A1 - Diehl, Bernd A1 - Monakhova, Yulia T1 - Multicomponent analysis of dietary supplements containing glucosamine and chondroitin: comparative low- and high-field NMR spectroscopic study JF - Analytical Sciences N2 - With the prevalence of glucosamine- and chondroitin-containing dietary supplements for people with osteoarthritis in the marketplace, it is important to have an accurate and reproducible analytical method for the quantitation of these compounds in finished products. NMR spectroscopic method based both on low- (80 MHz) and high- (500–600 MHz) field NMR instrumentation was established, compared and validated for the determination of chondroitin sulfate and glucosamine in dietary supplements. The proposed method was applied for analysis of 20 different dietary supplements. In the majority of cases, quantification results obtained on the low-field NMR spectrometer are similar to those obtained with high-field 500–600 MHz NMR devices. Validation results in terms of accuracy, precision, reproducibility, limit of detection and recovery demonstrated that the developed method is fit for purpose for the marketed products. The NMR method was extended to the analysis of methylsulfonylmethane, adulterant maltodextrin, acetate and inorganic ions. Low-field NMR can be a quicker and cheaper alternative to more expensive high-field NMR measurements for quality control of the investigated dietary supplements. High-field NMR instrumentation can be more favorable for samples with complex composition due to better resolution, simultaneously giving the possibility of analysis of inorganic species such as potassium and chloride. KW - Glucosamine KW - Chondroitin sulfate KW - Polysaccharides KW - Dietary supplements KW - High-field NMR Y1 - 2023 U6 - http://dx.doi.org/10.1007/s44211-023-00433-2 SN - 1348-2246 (Online) SN - 0910-6340 (Print) N1 - Corresponding author: Yulia Monakhova VL - 2023 PB - Springer Verlag CY - Cham ER -