TY - JOUR A1 - Mosset, Jean-Baptiste A1 - Devroede, Olivier A1 - Krieguer, Magalie A1 - Rey, M. A1 - Vieira, J.-M. A1 - Jung, J. H. A1 - Kuntner, Claudia A1 - Streun, Matthias A1 - Ziemons, Karl A1 - Auffray, Etiennette A1 - Sempere-Roldan, P. A1 - Lecoq, Paul A1 - Bruyndonckx, Peter A1 - Loude, Jean-François A1 - Tavernier, Stefaan A1 - Morel, Christian T1 - Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator JF - IEEE Transactions on Nuclear Science N2 - This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 1 SP - 25 EP - 29 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, Etiennette A1 - Barbier, R. A1 - Brandenburg, G. T1 - The ClearPET TM LSO/LuYAP phoswich scanner: a high performance small animal PET system JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes. Y1 - 2004 SN - 1082-3654 SP - 1728 EP - 1732 ER - TY - JOUR A1 - Auffray, Etiennette A1 - Bruyndonckx, P. A1 - Devroede, O. A1 - Fedorov, A. A1 - Ziemons, Karl T1 - The ClearPET project JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view. Y1 - 2004 SN - 0168-9002 N1 - Proceedings of the 2nd International Conference on Imaging Technologies in Biomedical Sciences VL - 527 IS - 1-2 SP - 171 EP - 174 ER - TY - JOUR A1 - Ziemons, Karl A1 - Achten, R. A1 - Auffray, Etiennette A1 - Müller-Veggian, Mattea T1 - The ClearPET™ neuro scanner: a dedicated LSO/LuYAP phoswich small animal PET scanner JF - 2004 IEEE Nuclear Science Symposium conference record : Nuclear Science Symposium, Medical Imaging Conference ; 16 - 22 October 2004, Rome, Italy ; [including the Symposium on Nuclear Power System (SNPS), 14th Room Temperature Semiconductor X- and Gamma-Ray Detectors Workshop and special focus workshops] / NPSS, Nuclear & Plasma Sciences Society. Guest ed.: J. Anthony Seibert Y1 - 2004 SN - 1082-3654 N1 - Nuclear Science Symposium Conference Record, 2004 IEEE SP - 2430 EP - 2433 PB - IEEE Operations Center CY - Piscataway, NJ ER - TY - JOUR A1 - Akimbekov, Nuraly S. A1 - Digel, Ilya A1 - Tastambek, Kuanysh T. A1 - Kozhahmetova, Marzhan A1 - Sherelkhan, Dinara K. A1 - Tauanov, Zhandos T1 - Hydrogenotrophic methanogenesis in coal-bearing environments: Methane production, carbon sequestration, and hydrogen availability JF - International Journal of Hydrogen Energy N2 - Methane is a valuable energy source helping to mitigate the growing energy demand worldwide. However, as a potent greenhouse gas, it has also gained additional attention due to its environmental impacts. The biological production of methane is performed primarily hydrogenotrophically from H2 and CO2 by methanogenic archaea. Hydrogenotrophic methanogenesis also represents a great interest with respect to carbon re-cycling and H2 storage. The most significant carbon source, extremely rich in complex organic matter for microbial degradation and biogenic methane production, is coal. Although interest in enhanced microbial coalbed methane production is continuously increasing globally, limited knowledge exists regarding the exact origins of the coalbed methane and the associated microbial communities, including hydrogenotrophic methanogens. Here, we give an overview of hydrogenotrophic methanogens in coal beds and related environments in terms of their energy production mechanisms, unique metabolic pathways, and associated ecological functions. KW - Coal KW - Methanogenesis KW - Methane KW - Hydrogenotrophic methanogens KW - H2 Y1 - 2024 U6 - https://doi.org/10.1016/j.ijhydene.2023.09.223 SN - 1879-3487 (online) SN - 0360-3199 (print) VL - 52 IS - Part D SP - 1264 EP - 1277 PB - Elsevier CY - New York ER - TY - JOUR A1 - Weihe, Stefan A1 - Ernst, Ansgar A1 - Röth, Thilo A1 - Proksch, Johannes T1 - Leichtmetall-Stahl-Verbundguss im Nutzfahrzeugbau JF - Lightweight Design N2 - In modernen Fahrzeugkarosserien der Großserie kommen zunehmend Materialmischbauweisen zur Anwendung. In Zusammenarbeit der Daimler AG, der Tower Automotive Holding GmbH, der Imperia GmbH sowie der Partnerunternehmen KSM Castings GmbH und Schaufler Tooling GmbH & Co. KG wird das Leichtbaupotenzial von Stahlblech-AluminiumverbundgussHybriden am Beispiel des vorderen Dachquerträgers des Mercedes-Benz Viano/Vito ausführlich untersucht. Y1 - 2013 SN - 2192-8738 (Online) SN - 1865-4819 (Print) VL - 6 IS - 2 SP - 38 EP - 43 PB - Springer CY - Berlin ER - TY - JOUR A1 - Grotendorst, Johannes A1 - Scott, Tony C. A1 - Aubert-Frécon, Monique A1 - Andrae, D. A1 - Morgan III, J. D. A1 - Glasser, M. L. T1 - Exchange Energy for Two-Active-Electron Diatomic Systems within the Surface Integral Method / Scott,T. C .; Aubert-Frécon, M. ; Andrae, D. ; Grotendorst, J. ; Morgan III, J. D. ; Glasser, M. L. JF - Applicable Algebra in Engineering, Communication and Computing. 15 (2004), H. 2 Y1 - 2004 SN - 0938-1279 N1 - zugl. Technical Report FZJ-ZAM-IB-2004-02, April 2004, 24 pages SP - 101 EP - 128 ER - TY - JOUR A1 - Lehnertz, Klaus A1 - Mormann, Florian A1 - Osterhage, Hannes A1 - Müller, Andy A1 - Prusseit, Jens A1 - Chernihovskyi, Anton A1 - Staniek, Matthäus A1 - Krug, Dieter A1 - Bialonski, Stephan A1 - Elger, Christian E. T1 - State-of-the-art of seizure prediction JF - Journal of Clinical Neurophysiology Y1 - 2007 U6 - https://doi.org/10.1097/WNP.0b013e3180336f16 SN - 1537-1603 VL - 24 IS - 2 SP - 147 EP - 153 ER - TY - JOUR A1 - Arida, Hassan A. A1 - Al-Haddad, Ameera A1 - Schöning, Michael Josef T1 - New Solid-State Organic Membrane Based Lead-Selective Micro-Electrode JF - International Journal of Electrochemical Science. 6 (2011), H. 9 Y1 - 2011 SN - 1452-3981 SP - 3858 EP - 3867 ER - TY - JOUR A1 - Mang, Thomas A1 - Roosen, C. A1 - Ansorge, Marion A1 - Leitner, W. T1 - Gaining pH-control in water/carbon dioxide biphasic systems / Abstract No. 1038 / Roosen, Ch. ; Ansorge, M. ; Mang, Thomas ; Leitner, W. ; Greiner, L. JF - Green solvents for processes : Lake Constance, Friedrichshafen, Germany, 8 - 11 October 2006 ; book of abstracts / DECHEMA e.V. Y1 - 2006 N1 - DECHEMA, Gesellschaft für Chemische Technik und Biotechnologie ; [Conference] ; ((Friedrichshafen) : 2006.10.08-11) PB - DECHEMA CY - Frankfurt am Main ER -