TY - CHAP A1 - Ritz, Thomas A1 - Izquierdo Tello, César A1 - Damm, Sebastian T1 - Connecting a pedelec to the cloud as basis for gamification in multi modal mobility planning T2 - MobileCloud 2014 : 2nd IEEE International Conference on Mobile Cloud Computing, Services, and Engineering Oxford, United Kingdom 7-10 April 2014 Y1 - 2014 SN - 978-1-4799-2504-9 U6 - https://doi.org/10.1109/MobileCloud.2014.25 SP - 101 EP - 108 PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Fuchs, Katharina A1 - Dieringer, Matthias A. A1 - Özerdem, Celal A1 - Patel, Nishan A1 - Renz, Wolfgang A1 - Greiser, Andreas A1 - Elgeti, Thomas A1 - Niendorf, Thoralf T1 - Detailing the use of magnetohydrodynamic effects for synchronization of MRI with the cardiac cycle: A feasibility study JF - Journal of Magnetic Resonance Imaging N2 - Purpose: To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle. Materials and Methods: The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.05–7.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization. Results: The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs. Conclusion: This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364–372. © 2012 Wiley Periodicals, Inc. Y1 - 2012 U6 - https://doi.org/10.1002/jmri.23634 SN - 1522-2586 VL - 36 IS - 2 SP - 364 EP - 372 PB - Wiley-Liss CY - New York ER - TY - CHAP A1 - Wittig, M. A1 - Rütters, René A1 - Bragard, Michael ED - Reiff-Stephan, Jörg ED - Jäkel, Jens ED - Schwarz, André T1 - Application of RL in control systems using the example of a rotatory inverted pendulum T2 - Tagungsband AALE 2024 : Fit für die Zukunft: praktische Lösungen für die industrielle Automation N2 - In this paper, the use of reinforcement learning (RL) in control systems is investigated using a rotatory inverted pendulum as an example. The control behavior of an RL controller is compared to that of traditional LQR and MPC controllers. This is done by evaluating their behavior under optimal conditions, their disturbance behavior, their robustness and their development process. All the investigated controllers are developed using MATLAB and the Simulink simulation environment and later deployed to a real pendulum model powered by a Raspberry Pi. The RL algorithm used is Proximal Policy Optimization (PPO). The LQR controller exhibits an easy development process, an average to good control behavior and average to good robustness. A linear MPC controller could show excellent results under optimal operating conditions. However, when subjected to disturbances or deviations from the equilibrium point, it showed poor performance and sometimes instable behavior. Employing a nonlinear MPC Controller in real time was not possible due to the high computational effort involved. The RL controller exhibits by far the most versatile and robust control behavior. When operated in the simulation environment, it achieved a high control accuracy. When employed in the real system, however, it only shows average accuracy and a significantly greater performance loss compared to the simulation than the traditional controllers. With MATLAB, it is not yet possible to directly post-train the RL controller on the Raspberry Pi, which is an obstacle to the practical application of RL in a prototyping or teaching setting. Nevertheless, RL in general proves to be a flexible and powerful control method, which is well suited for complex or nonlinear systems where traditional controllers struggle. KW - Rotatory Inverted Pendulum KW - MPC KW - LQR KW - PPO KW - Reinforcement Learning Y1 - 2024 SN - 978-3-910103-02-3 U6 - https://doi.org/10.33968/2024.53 N1 - 20. AALE-Konferenz. Bielefeld, 06.03.-08.03.2024. (Tagungsband unter https://doi.org/10.33968/2024.29) SP - 241 EP - 248 PB - le-tex publishing services GmbH CY - Leipzig ER - TY - JOUR A1 - Gräßl, Andreas A1 - Renz, Wolfgang A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Winter, Lukas A1 - Özerdem, Celal A1 - Rieger, Jan A1 - Kellmann, Peter A1 - Santoro, Davide A1 - Lindel, Tomasz D. A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Niendorf, Thoralf T1 - Modular 32-channel transceiver coil array for cardiac MRI at 7.0T JF - Magnetic Resonance in Medicine N2 - Purpose To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. Methods The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. Results Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. Conclusion The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T. Y1 - 2013 U6 - https://doi.org/10.1002/mrm.24903 SN - 1522-2594 VL - 72 IS - 1 SP - 276 EP - 290 PB - Wiley-Liss CY - New York ER - TY - CHAP A1 - Kramer, Pia A1 - Bragard, Michael A1 - Ritz, Thomas A1 - Ferfer, Ute A1 - Schiffers, Tim T1 - Visualizing, Enhancing and Predicting Students’ Success through ECTS Monitoring T2 - 2024 IEEE Global Engineering Education Conference (EDUCON) N2 - This paper serves as an introduction to the ECTS monitoring system and its potential applications in higher education. It also emphasizes the potential for ECTS monitoring to become a proactive system, supporting students by predicting academic success and identifying groups of potential dropouts for tailored support services. The use of the nearest neighbor analysis is suggested for improving data analysis and prediction accuracy. KW - Monitoring KW - Engineering education KW - Data visualization KW - Accuracy KW - Data analysis Y1 - 2024 U6 - https://doi.org/10.1109/EDUCON60312.2024.10578652 SN - 2165-9559 SN - 2165-9567 (eISSN) N1 - 2024 IEEE Global Engineering Education Conference (EDUCON), 08-11 May 2024, Kos Island, Greece PB - IEEE CY - New York, NY ER - TY - CHAP A1 - Schult, Prince Garcia A1 - Losse, Ann-Kathrin A1 - Czarnecki, Christian A1 - Sultanow, Eldar T1 - Proposing a Framework to address the Sustainable Development Goals T2 - EnviroInfo 2023 N2 - Reducing poverty, protecting the planet, and improving life on earth for everyone are the essential goals of the "2030 Agenda for Sustainable Development"committed by the United Nations (UN). Achieving those goals will require technological innovation as well as their implementation in almost all areas of our business and day-to-day life. This paper proposes a high-level framework that collects and structures different uses cases addressing the goals defined by the UN. Hence, it contributes to the discussion by proposing technical innovations that can be used to achieve those goals. As an example, the goal "Climate Actionïs discussed in detail by describing use cases related to tackling biodiversity loss in order to conservate ecosystems. Y1 - 2023 SN - 978-3-88579-736-4 U6 - https://doi.org/10.18420/env2023-022 SN - 1617-5468 N1 - EnviroInfo 2023, 11. - 23. October 2023, Garching, Germany SP - 243 EP - 249 PB - GI - Gesellschaft für Informatik CY - Bonn ER - TY - CHAP A1 - Buxbaum, Bernd A1 - Hess, Holger A1 - Ringbeck, Thorsten ED - Voges, Edgar T1 - The photonic mixer device : new perspectives in optical wireless communication T2 - International Workshop on Optical MEMS and Integrated Optics : Universität Dortmund, Universitätskolleg Bommerholz, 11. & 12. June 2001 Y1 - 2001 N1 - International Workshop on Optical MEMS and Integrated Optics <2001, Dortmund> SP - (12)1 EP - (12)5 PB - Univ. CY - Dortmund ER - TY - CHAP A1 - Ringbeck, Thorsten A1 - Albrecht, M. A1 - Frey, J. ED - Lerch, Reinhard T1 - Time-of-Flight 3D-camera for autonomous navigation and industrial automation T2 - Proceedings : 11th international conference, 13 - 15 May 2003, Exhibition Centre Nuremberg, Germany ; an event of the Association for Sensor Technology, AMA Y1 - 2003 N1 - Internationale Messe mit Kongress Sensor PB - AMA Service CY - Wunstorf/Germany ET - CD-ROM-Ausg. ER - TY - CHAP A1 - Hagebeuker, Bianca A1 - Ringbeck, Thorsten A1 - Frydlewicz, Paul A1 - Jesorsky, Oliver A1 - Sünkel, Thomas ED - Grote, Caspar T1 - PMD-Sensoren als Schlüsselkomponenten für die mehrdimensionale Umfelderfassung des Fahrzeuginnenraums T2 - Begleittexte zum Entwicklerforum KFZ-Elektronik & FlexRay Solution Day : 15.Mai 2007, Ludwigsburg Y1 - 2007 N1 - Entwicklerforum Kfz-Elektronik <2007, Ludwigsburg> ; FlexRay Solution Day <2007, Ludwigsburg> SP - 287 EP - 296 PB - WEKA-Fachzeitschr.-Verl. CY - Poing ER - TY - CHAP A1 - Grothof, M. A1 - Schwarte, Rudolf A1 - Buxbaum, Bernd A1 - Ringbeck, Thorsten ED - Wagner, Elmar T1 - Product monitoring with MSM-PMD-Array T2 - Proceedings / OPTO 2002 : an event of the Association for Sensor Technology AMA ; 14 - 16 May 2002, Exhibition Centre Erfurt, Germany / International Conference Optoelectronics, Optical Sensors & Measuring Techniques Y1 - 2002 N1 - OPTO <5, 2002, Erfurt> ; International Conference Optoelectronics, Optical Sensors & Measuring Techniques SP - 41 EP - 47 PB - AMA Service GmbH CY - Wunsdorf ER -