TY - JOUR A1 - Heinze, D. A1 - Mang, Thomas A1 - Popescu, C. A1 - Weichold, O. T1 - Effect of side chain length and degree of polymerization on the decomposition and crystallization behaviour of chlorinated poly(vinyl ester) oligomers JF - Thermochimica Acta N2 - Four members of a homologous series of chlorinated poly(vinyl ester) oligomers CCl₃–(CH₂CH (OCO(CH₂)ₘCH₃))ₙ–Cl with degrees of polymerization of 10 and 20 were prepared by telomerisation using carbon tetrachloride. The number of side chain carbon atoms ranges from 2 (poly(vinyl acetate) to 18 (poly(vinyl stearate)). The effect of the n-alkyl side chain length and of the degree of polymerization on the thermal stability and crystallization behaviour of the synthesized compounds was investigated. All oligomers degrade in two major steps by first losing HCl and side chains with subsequent breakdown of the backbone. The members with short side chains, up to poly(vinyl octanoate), are amorphous and show internal plasticization, whereas those with high number of side chain carbon atoms are semi-crystalline due to side-chain crystallization. A better packing for poly(vinyl stearate) is also noticeable. The glass transition and melting temperatures as well as the onset temperature of decomposition are influenced to a larger extent by the side chain length than by the degree of polymerization. Thermal stability is improved if both the size and number of side chains increase, but only a long side chain causes a significant increase of the resistance to degradation. This results in a stabilization of PVAc so that oligomers from poly(vinyl octanoate) on are stable under atmospheric conditions. Thus, the way to design stable, chlorinated PVEs oligomers is to use a long n-alkyl side chain. Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.tca.2016.05.015 SN - 0040-6031 (electronic) VL - 637 SP - 143 EP - 153 PB - Elsevier CY - Amsterdam ER - TY - BOOK A1 - Feuerriegel, Uwe T1 - Verfahrenstechnik mit EXCEL: Verfahrenstechnische Berechnungen effektiv durchführen und professionell dokumentieren Y1 - 2016 SN - 978-3-658-02902-9 U6 - http://dx.doi.org/10.1007/978-3-658-02903-6 N1 - 152 Abbildungen, 94 Abbildungen in Farbe Gedruckt in der Bibliothek unter der Signatur: 21 ZNK 11 PB - Springer Fachmedien CY - Wiesbaden ER - TY - BOOK A1 - Lauth, Jakob T1 - Physikalische Chemie, 5: Elektrochemie Y1 - 2016 SN - 978-3-662-47559-1 PB - Springer CY - Berlin ER - TY - BOOK A1 - Lauth, Jakob T1 - Physikalische Chemie, 4: Reaktionskinetik Y1 - 2016 SN - 978-3-662-47674-1 PB - Springer CY - Berlin ER - TY - BOOK A1 - Lauth, Jakob T1 - Physikalische Chemie, 3: Phasengleichgewichte Y1 - 2016 SN - 978-3-662-47571-3 PB - Springer CY - Berlin ER - TY - BOOK A1 - Lauth, Jakob T1 - Physikalische Chemie, 2: Chemische Thermodynamik Y1 - 2016 SN - 978-3-662-47621-5 PB - Springer CY - Berlin ER - TY - BOOK A1 - Lauth, Jakob T1 - Physikalische Chemie, 1: Grundlagen der Thermodynamik und Verhalten der Gase Y1 - 2016 SN - 978-3-662-47676-5 PB - Springer CY - Berlin ER - TY - BOOK A1 - Lauth, Jakob A1 - Kowalczyk, Jürgen T1 - Einführung in die Physik und Chemie der Grenzflächen und Kolloide Y1 - 2016 SN - 978-3-662-47018-3 U6 - http://dx.doi.org/10.1007/978-3-662-47018-3 PB - Springer CY - Berlin ER - TY - JOUR A1 - Molinnus, Denise A1 - Sorich, Maren A1 - Bartz, Alexander A1 - Siegert, Petra A1 - Willenberg, Holger S. A1 - Lisdat, Fred A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards an adrenaline biosensor based on substrate recycling amplification in combination with an enzyme logic gate JF - Sensors and Actuators B: Chemical N2 - An amperometric biosensor using a substrate recycling principle was realized for the detection of low adrenaline concentrations (1 nM) by measurements in phosphate buffer and Ringer’s solution at pH 6.5 and pH 7.4, respectively. In proof-of-concept experiments, a Boolean logic-gate principle has been applied to develop a digital adrenaline biosensor based on an enzyme AND logic gate. The obtained results demonstrate that the developed digital biosensor is capable for a rapid qualitative determination of the presence/absence of adrenaline in a YES/NO statement. Such digital biosensor could be used in clinical diagnostics for the control of a correct insertion of a catheter in the adrenal veins during adrenal venous-sampling procedure. Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.snb.2016.06.064 SN - 0925-4005 VL - 237 SP - 190 EP - 195 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ghosch, S. A1 - Baier, M. A1 - Schütz, J. A1 - Schneider, Felix A1 - Scherer, Ulrich W. T1 - Analysis of electronic autoradiographs by mathematical post-processing JF - Radiation Effects and Defects in Solids: Incorporating plasma science and plasma technology N2 - Autoradiography is a well-established method of nuclear imaging. When different radionuclides are present simultaneously, additional processing is needed to distinguish distributions of radionuclides. In this work, a method is presented where aluminium absorbers of different thickness are used to produce images with different cut-off energies. By subtracting images pixel-by-pixel one can generate images representing certain ranges of β-particle energies. The method is applied to the measurement of irradiated reactor graphite samples containing several radionuclides to determine the spatial distribution of these radionuclides within pre-defined energy windows. The process was repeated under fixed parameters after thermal treatment of the samples. The greyscale images of the distribution after treatment were subtracted from the corresponding pre-treatment images. Significant changes in the intensity and distribution of radionuclides could be observed in some samples. Due to the thermal treatment parameters the most significant differences were observed in the ³H and ¹⁴C inventory and distribution. Y1 - 2016 U6 - http://dx.doi.org/10.1080/10420150.2016.1155587 SN - 1029-4953 VL - 171 IS - 1-2 SP - 161 EP - 172 PB - Taylor & Francis CY - London ER -