TY - JOUR A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - FEM-based shakedown analysis of hardening structures JF - Asia Pacific journal on computational engineering N2 - This paper develops a new finite element method (FEM)-based upper bound algorithm for limit and shakedown analysis of hardening structures by a direct plasticity method. The hardening model is a simple two-surface model of plasticity with a fixed bounding surface. The initial yield surface can translate inside the bounding surface, and it is bounded by one of the two equivalent conditions: (1) it always stays inside the bounding surface or (2) its centre cannot move outside the back-stress surface. The algorithm gives an effective tool to analyze the problems with a very high number of degree of freedom. Our numerical results are very close to the analytical solutions and numerical solutions in literature. Y1 - 2014 U6 - https://doi.org/10.1186/2196-1166-1-4 SN - 2196-1166 (E-Journal) IS - 1 SP - Article No. 4 PB - SpringerOpen CY - Berlin ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Maki, Rafael M. A1 - Paulovich, Fernando V. A1 - Werner, Frederik A1 - Poghossian, Arshak A1 - Oliveira, Maria C. F. de A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Use of Information Visualization Methods Eliminating Cross Talk in Multiple Sensing Units Investigated for a Light-Addressable Potentiometric Sensor JF - Analytical Chemistry (2010) Y1 - 2010 SN - 0003-2700 SP - 61 EP - 65 ER - TY - JOUR A1 - Albanna, W. A1 - Conzen, C. A1 - Weiss, M. A1 - Clusmann, H. A1 - Fuest, M. A1 - Mueller, M. A1 - Brockmann, M.A. A1 - Vilser, W. A1 - Schmidt-Trucksäss, A. A1 - Hoellig, A. A1 - Seiz, M. A1 - Thomé, C. A1 - Kotliar, Konstantin A1 - Schubert, G.A. T1 - Retinal Vessel Analysis (RVA) in the context of subarachnoid hemorrhage: A proof of concept study JF - PLoS ONE N2 - Background Timely detection of impending delayed cerebral ischemia after subarachnoid hemorrhage (SAH) is essential to improve outcome, but poses a diagnostic challenge. Retinal vessels as an embryological part of the intracranial vasculature are easily accessible for analysis and may hold the key to a new and non-invasive monitoring technique. This investigation aims to determine the feasibility of standardized retinal vessel analysis (RVA) in the context of SAH. Methods In a prospective pilot study, we performed RVA in six patients awake and cooperative with SAH in the acute phase (day 2–14) and eight patients at the time of follow-up (mean 4.6±1.7months after SAH), and included 33 age-matched healthy controls. Data was acquired using a manoeuvrable Dynamic Vessel Analyzer (Imedos Systems UG, Jena) for examination of retinal vessel dimension and neurovascular coupling. Results Image quality was satisfactory in the majority of cases (93.3%). In the acute phase after SAH, retinal arteries were significantly dilated when compared to the control group (124.2±4.3MU vs 110.9±11.4MU, p<0.01), a difference that persisted to a lesser extent in the later stage of the disease (122.7±17.2MU, p<0.05). Testing for neurovascular coupling showed a trend towards impaired primary vasodilation and secondary vasoconstriction (p = 0.08, p = 0.09 resp.) initially and partial recovery at the time of follow-up, indicating a relative improvement in a time-dependent fashion. Conclusion RVA is technically feasible in patients with SAH and can detect fluctuations in vessel diameter and autoregulation even in less severely affected patients. Preliminary data suggests potential for RVA as a new and non-invasive tool for advanced SAH monitoring, but clinical relevance and prognostic value will have to be determined in a larger cohort. Y1 - 2016 U6 - https://doi.org/10.1371/journal.pone.0158781 SN - 1932-6203 VL - 11 IS - 7 PB - PLOS CY - San Francisco ER - TY - JOUR A1 - Wagner, Torsten A1 - Vornholt, Wolfgang A1 - Werner, Frederik A1 - Yoshinobu, Tatsuo A1 - Miyamoto, Ko-Ichiro A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Light-addressable potentiometric sensor (LAPS) combined with magnetic beads for pharmaceutical screening JF - Physics in medicine N2 - The light-addressable potentiometric sensor (LAPS) has the unique feature to address different regions of a sensor surface without the need of complex structures. Measurements at different locations on the sensor surface can be performed in a common analyte solution, which distinctly simplifies the fluidic set-up. However, the measurement in a single analyte chamber prevents the application of different drugs or different concentrations of a drug to each measurement spot at the same time as in the case of multi-reservoir-based set-ups. In this work, the authors designed a LAPS-based set-up for cell culture screening that utilises magnetic beads loaded with the endotoxin (lipopolysaccharides, LPS), to generate a spatially distributed gradient of analyte concentration. Different external magnetic fields can be adjusted to move the magnetic beads loaded with a specific drug within the measurement cell. By recording the metabolic activities of a cell layer cultured on top of the LAPS surface, this work shows the possibility to apply different concentrations of a sample along the LAPS measurement spots within a common analyte solution. Y1 - 2016 U6 - https://doi.org/10.1016/j.phmed.2016.03.001 SN - 2352-4510 VL - 2016 IS - 1 SP - 2 EP - 7 ER - TY - JOUR A1 - Doll, Theodor A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Engineering of functional interfaces / Theodor Doll ; Torsten Wagner ; Patrick Wagner ; Michael J. Schöning (eds.) JF - Physica status solidi (a) Y1 - 2016 U6 - https://doi.org/10.1002/pssa.201670641 SN - 1862-6319 VL - 213 IS - 6 SP - 1393 EP - 1394 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Kolditz, Melanie A1 - Albin, Thivaharan A1 - Abel, Dirk A1 - Fasse, Alessandro A1 - Brüggemann, Gert-Peter A1 - Albracht, Kirsten T1 - Evaluation of foot position and orientation as manipulated variables to control external knee adduction moments in leg extension training JF - Computer methods and programs in biomedicine N2 - Background and Objective Effective leg extension training at a leg press requires high forces, which need to be controlled to avoid training-induced damage. In order to avoid high external knee adduction moments, which are one reason for unphysiological loadings on knee joint structures, both training movements and the whole reaction force vector need to be observed. In this study, the applicability of lateral and medial changes in foot orientation and position as possible manipulated variables to control external knee adduction moments is investigated. As secondary parameters both the medio-lateral position of the center of pressure and the frontal-plane orientation of the reaction force vector are analyzed. Methods Knee adduction moments are estimated using a dynamic model of the musculoskeletal system together with the measured reaction force vector and the motion of the subject by solving the inverse kinematic and dynamic problem. Six different foot conditions with varying positions and orientations of the foot in a static leg press are evaluated and compared to a neutral foot position. Results Both lateral and medial wedges under the foot and medial and lateral shifts of the foot can influence external knee adduction moments in the presented study with six healthy subjects. Different effects are observed with the varying conditions: the pose of the leg is changed and the direction and center of pressure of the reaction force vector is influenced. Each effect results in a different direction or center of pressure of the reaction force vector. Conclusions The results allow the conclusion that foot position and orientation can be used as manipulated variables in a control loop to actively control knee adduction moments in leg extension training. KW - External knee adduction moments KW - Manipulated variables KW - Inverse dynamic problem KW - Inverse kinematic problem KW - Musculoskeletal model Y1 - 2016 U6 - https://doi.org/10.1016/j.cmpb.2016.09.005 SN - 0169-2607 N1 - Part of special issue: "SI: Personalised Models and System Identification" VL - 171 SP - 81 EP - 86 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Belavy, Daniel L. A1 - Albracht, Kirsten A1 - Bruggemann, Gert-Peter A1 - Vergroesen, Pieter-Paul A. A1 - Dieen, Jaap H. van T1 - Can exercise positively influence the intervertebral disc? JF - Sports Medicine N2 - To better understand what kinds of sports and exercise could be beneficial for the intervertebral disc (IVD), we performed a review to synthesise the literature on IVD adaptation with loading and exercise. The state of the literature did not permit a systematic review; therefore, we performed a narrative review. The majority of the available data come from cell or whole-disc loading models and animal exercise models. However, some studies have examined the impact of specific sports on IVD degeneration in humans and acute exercise on disc size. Based on the data available in the literature, loading types that are likely beneficial to the IVD are dynamic, axial, at slow to moderate movement speeds, and of a magnitude experienced in walking and jogging. Static loading, torsional loading, flexion with compression, rapid loading, high-impact loading and explosive tasks are likely detrimental for the IVD. Reduced physical activity and disuse appear to be detrimental for the IVD. We also consider the impact of genetics and the likelihood of a ‘critical period’ for the effect of exercise in IVD development. The current review summarises the literature to increase awareness amongst exercise, rehabilitation and ergonomic professionals regarding IVD health and provides recommendations on future directions in research. KW - Intradiscal Pressure KW - Annulus Fibrosus KW - Disc Degeneration KW - Nucleus Pulposus KW - Intervertebral Disc Y1 - 2016 U6 - https://doi.org/10.1007/s40279-015-0444-2 SN - 1179-2035 VL - 46 IS - 4 SP - 473 EP - 485 PB - Springer CY - Berlin ER - TY - JOUR A1 - Seynnes, O. R. A1 - Bojsen-Moller, J. A1 - Albracht, Kirsten A1 - Arndt, A. A1 - Cronin, N. J. A1 - Finni, T. A1 - Magnusson, S. P. T1 - Ultrasound-based testing of tendon mechanical properties: a critical evaluation JF - Journal of Applied Physiology Y1 - 2015 U6 - https://doi.org/10.1152/japplphysiol.00849.2014 SN - 8750-7587 VL - 118 IS - 2 SP - 133 EP - 141 ER - TY - JOUR A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Exercise-induced changes in triceps surae tendon stiffness and muscle strength affect running economy in humans JF - European Journal of Applied Physiology Y1 - 2013 U6 - https://doi.org/10.1007/s00421-012-2585-4 SN - 1439-6327 VL - 113 IS - 6 SP - 1605 EP - 1615 PB - Springer CY - Berlin ER - TY - JOUR A1 - Karamanidis, Kiros A1 - Albracht, Kirsten A1 - Braunstein, Bjoern A1 - Catala, Maria Moreno A1 - Goldmann, Jan-Peter A1 - Brüggemann, Gert-Peter T1 - Lower leg musculoskeletal geometry and sprint performance JF - Gait and Posture N2 - The purpose of this study was to investigate whether sprint performance is related to lower leg musculoskeletal geometry within a homogeneous group of highly trained 100-m sprinters. Using a cluster analysis, eighteen male sprinters were divided into two groups based on their personal best (fast: N = 11, 10.30 ± 0.07 s; slow: N = 7, 10.70 ± 0.08 s). Calf muscular fascicle arrangement and Achilles tendon moment arms (calculated by the gradient of tendon excursion versus ankle joint angle) were analyzed for each athlete using ultrasonography. Achilles tendon moment arm, foot and ankle skeletal geometry, fascicle arrangement as well as the ratio of fascicle length to Achilles tendon moment arm showed no significant (p > 0.05) correlation with sprint performance, nor were there any differences in the analyzed musculoskeletal parameters between the fast and slow sprinter group. Our findings provide evidence that differences in sprint ability in world-class athletes are not a result of differences in the geometrical design of the lower leg even when considering both skeletal and muscular components. Y1 - 2011 U6 - https://doi.org/10.1016/j.gaitpost.2011.03.009 SN - 0966-6362 VL - 34 IS - 1 SP - 138 EP - 141 PB - Elsevier CY - Amsterdam ER -