TY - CHAP A1 - Butenweg, Christoph A1 - Gellert, Christoph T1 - Displacement based design of masonry structures T2 - Proceedings of the 14th International Brick and Block Masonry Conference : (Incorporating the 8th Australasian Masonry Conference) : Sydney, Australia, 13.-20. February 2008 / ed. Mark Masia ... Y1 - 2008 SN - 978-19-2070-1-92-5 SP - 1 EP - 10 PB - University of Newcastle CY - Callaghan ER - TY - CHAP A1 - Butenweg, Christoph A1 - Gellert, Christoph A1 - Meskouris, Konstantin T1 - Ein neuer Ansatz zum Nachweis von Mauerwerksbauten T2 - Berichte der Fachtagung Baustatik - Baupraxis 10 : am 17. und 18. März 2008 in Karlsruhe / Hrsg.: Werner Wagner. Institut für Baustatik, Universität Karlsruhe (TH) Y1 - 2008 SN - 978-3-935322-14-0 SP - 103 EP - 116 PB - Inst. für Baustatik, Univ. Karlsruhe (TH) CY - Karlsruhe ER - TY - JOUR A1 - Mahmoudi, Mohammad A1 - Fleischhaker, Robert A1 - Sahrai, Mostafa A1 - Evers, Jörg T1 - Group velocity control in the ultraviolet domain via interacting dark-state resonances JF - Journal of physics B: Atomic, molecular and optical physics Y1 - 2008 U6 - http://dx.doi.org/10.1088/0953-4075/41/2/025504 SN - 0953-4075 SN - 1361-6455 VL - 41 IS - 2 SP - 25504 EP - 25600 ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg T1 - Nonlinear effects in pulse propagation through Doppler-broadened closed-loop atomic media JF - Physical Review A - Atomic, molecular, and optical physics Y1 - 2008 U6 - http://dx.doi.org/10.1103/PhysRevA.77.043805 SN - 1050-2947 VL - 77 IS - 4 SP - 043805 ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg T1 - Four-wave mixing enhanced white-light cavity JF - Physical Review A - Atomic, molecular, and optical physics Y1 - 2008 SN - 0556-2791 VL - 78 IS - 5 SP - 051802(R) ER - TY - JOUR A1 - Albracht, Kirsten A1 - Arampatzis, A. A1 - Baltzopoulos, V. T1 - Assessment of muscle volume and physiological cross-sectional area of the human triceps surae muscle in vivo JF - Journal of Biomechanics Y1 - 2008 U6 - http://dx.doi.org/10.1016/j.jbiomech.2008.04.020 SN - 0021-9290 VL - 41 SP - 2211 EP - 2218 ER - TY - JOUR A1 - Lerchl, Alexander A1 - Krüger, Heike A1 - Niehaus, Michael A1 - Streckert, Joachim R. A1 - Bitz, Andreas A1 - Hansen, Volkert T1 - Effects of mobile phone electromagnetic fields at nonthermal SAR values on melatonin and body weight of Djungarian hamsters (Phodopus sungorus) JF - Journal of Pineal Research Y1 - 2008 U6 - http://dx.doi.org/10.1111/j.1600-079X.2007.00522.x SN - 1600-079X VL - 44 IS - 3 SP - 267 EP - 272 ER - TY - JOUR A1 - Tippkötter, Nils A1 - Deterding, A. A1 - Ulber, Roland T1 - Determination of acetic acid in fermentation broth by gas-diffusion technique JF - Engineering in Life Sciences N2 - Due to the interfering effects of acetic acid in many fermentation processes, a gas-diffusion technique was developed for the online determination of acetic acid. The measurements were accomplished with a flow diffusion analysis (FDA) unit from the TRACE Analytics GmbH, Braunschweig, Germany. The diffusion analysis is based on the UV-absorbance of acetic acid at 205 nm. The measurement was achieved by the separation of an acceptor and a carrier stream (acidified fermentation broth) using a gas permeable polytetrafluoroethylene (PTFE) membrane, whereby broth constituents that would otherwise disturb the UV-measurement of acetic acid, are held back efficiently. Merely, the fermentation by-products, e.g. formic acid, is capable of diffusing through the membrane. While formic acid can disturb the measurement, carbon dioxide does not absorb at 205 nm. The method operates with time-dependent sample enrichment. During the analysis, a small volume of the acceptor stream is stopped for a defined time interval in the acceptor chamber. During this period, the gaseous acetic acid diffuses through the membrane and is enriched in the acceptor chamber. Subsequently after the enrichment, the acceptor stream flows through a UV-detector. The intensity of the signal is proportional to the acetic acid concentration. Online measurements in bioreactors via a sterile filtration probe have been accomplished. A linear calibration in the range of 0.5–5.0 g/L acetic acid with a relative standard deviation of <5 % was obtained. A sampling rate of 8 samples per hour was possible. The system was applied for the determination of acetic acid in E. coli fermentation broth. The instrument is easy to clean, very user-friendly and does not require any toxic or expensive reagents. Y1 - 2008 U6 - http://dx.doi.org/10.1002/elsc.200820227 VL - 8 IS - 1, Special Issue: Technical Systems for the Use in Life Sciences SP - 62 EP - 67 ER - TY - CHAP A1 - Tippkötter, Nils A1 - Schünemann, V. A1 - Christmann, R. A1 - Pasteur, A. A1 - Schweizer, J. A1 - Ulber, R. ED - Beckmann, Dieter T1 - Bioaffinity Layering magnetisierbarer Mikro- und Nanopartikel T2 - Technische Systeme für die Lebenswissenschaften : 14. Heiligenstädter Kolloquium, Heilbad Heiligenstadt, 22.09. - 24.09.2008 Y1 - 2008 SN - 978-3-00-025695-0 SP - 97 EP - 98 CY - Heiligenstadt ER - TY - JOUR A1 - Tippkötter, Nils A1 - Roikaew, W. A1 - Ulber, R. T1 - Nitrate removal from whey concentrate with biotechnological regeneration of the waste water JF - European dairy magazine : EDM Y1 - 2008 SN - 0936-6318 IS - 1 SP - 30 EP - 32 ER -