TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Kaneko, Kazumi A1 - Matsuo, Akira A1 - Wagner, Torsten A1 - Kanoh, Shin`ichiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Miniaturized chemical imaging sensor system using an OLED display panel JF - Procedia Engineering N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the currentvoltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated. Y1 - 2010 U6 - https://doi.org/10.1016/j.proeng.2010.09.160 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 516 EP - 519 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Srivastava, Alok A1 - Singh, Virendra A1 - Aggarwal, Pranav A1 - Schneeweiss, F. A1 - Scherer, Ulrich W. A1 - Friedrich, W. T1 - Optical studies of insulating polymers for radiation dose monitoring JF - Indian Journal of Pure and Applied Physics N2 - The optical study carried out on insulating polymers namely polyethyleneterephthalate (PET) and polyvinylchloride (PVC) has been described. The polymers are exposed to different radiation doses by exposing them to swift heavy ions of carbon (90 MeV), silicon (120 MeV) and nickel (100 MeV) which influence on their optical properties. The studies show that amongst the investigated polymers, PVC and PET have potential for application as dosimeter beyond a threshold dose which is strongly dependent on the nature of the material and the radiation type. The optical micrographs show a distinct change in colour of the sample with increase in radiation dose. Y1 - 2010 SN - 0019-5596 N1 - Special Issue: SI VL - 48 IS - 11 SP - 782 EP - 786 PB - Council Of Scientific And Industrial Research (CSIR), National Institute Of Science Communication and Policy Research (NIScPR) CY - New Delhi ER - TY - JOUR A1 - Gebhardt, Andreas A1 - Schmidt, Frank-Michael A1 - Hötter, Jan-Steffen A1 - Sokalla, Wolfgang A1 - Sokalla, Patrick T1 - Additive manufacturing by selective laser melting the realizer desktop machine and its application for the dental industry JF - Physics Procedia N2 - Additive Manufacturing of metal parts by Selective Laser Melting has become a powerful tool for the direct manufacturing of complex parts mainly for the aerospace and medical industry. With the introduction of its desktop machine, Realizer targeted the dental market. The contribution describes the special features of the machine, discusses details of the process and shows manufacturing results focused on metal dental devices. KW - scan strategy KW - dental bridges KW - cobald chrome KW - Selective Laser Melting (SLM) KW - additive manufacturing Y1 - 2010 U6 - https://doi.org/10.1016/j.phpro.2010.08.082 SN - 1875-3892 N1 - Laser Assisted Net Shape Engineering 6, Proceedings of the LANE 2010, Part 2 VL - 5 B IS - 2 SP - 543 EP - 549 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Alexopoulos, Spiros A1 - Hoffschmidt, Bernhard T1 - Solarthermische Kraftwerke mit thermischen Speichern JF - Chemie Ingenieur Technik N2 - Solarthermische Kraftwerke stellen eine bedeutende Technologieoption für einen nachhaltigen Energiemix der Zukunft dar. Sie konzentrieren die Strahlung der Sonne, erzeugen Wärme und wandeln diese mit konventioneller Kraftwerkstechnik in Strom um. Die Wärme kann auch gespeichert werden, so dass der Betrieb während des Durchzugs von Wolken möglich ist und bis in die Abendstunden hinein verlängert werden kann. Zu den solarthermischen Kraftwerken gehören neben der Parabolrinne und dem Solarturm der Fresnel-Kollektor und die Dish-Stirling-Systeme. Im Zuge einer späteren Vergrößerung des Solarfeldes von Solarkraftwerken kann mithilfe von thermischen Energiespeichern die solare Energieerzeugung bei gleichbleibender Kraftwerksleistung sukzessiv bis um den Faktor 3 erweitert werden. Es besteht so die Möglichkeit einer massiven Substitution von fossilen Brennstoffen.Bei den ersten solarthermischen Speichern für die SEGS-Parabolrinnekraftwerke wurde Öl als Speichermedium eingesetzt. Ein weiteres Speichermedium ist Salzschmelze, die im Andasol-1-Projekt in Spanien sowie bei Solarturmkraftwerken eingesetzt wird. Beton ist ein weiteres mögliches Speichermaterial für Parabolrinnensysteme. Eine weitere Alternative bei einem Solarturmkraftwerk mit Luft als Wärmeträgermedium ist die Verwendung von keramischen Feuerfestmaterialien in Form von Schüttungen oder stapelbaren, porösen Elementen. In Jülich wurde das weltweit erste solarthermische Turmkraftwerk mit einer Leistung von 1,5 MWe, das Luft als Wärmeträgermedium einsetzt und einen solchen Speicher verwendet, gebaut. Y1 - 2010 SN - 1522-2640 U6 - https://doi.org/10.1002/cite.201050678 N1 - Special Issue: ProcessNet-Jahrestagung 2010 und 28. Jahrestagung der Biotechnologen VL - 82 IS - 9 SP - 1606 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Poghossian, Arshak A1 - Wagner, Holger A1 - Schöning, Michael Josef T1 - Automatisiertes „wafer level“-Testsystem zur Charakterisierung von siliziumbasierten Chemo- und Biosensoren JF - Tagungsband: Sensoren und Messsysteme 2010 N2 - Es wurde ein automatisiertes, computerunterstütztes Testsystem für die Funktionsprüfung und Charakterisierung von (bio-)chemischen Sensoren auf Waferebene entwickelt und in einen konventionellen Spitzenmessplatz integriert. Das System ermöglicht die Charakterisierung und Identifizierung „funktionstauglicher“ Sensoren bereits auf Waferebene zwischen den einzelnen Herstellungsschritten, wodurch weitere, bisher übliche Verarbeitungsschritte wie das Fixieren, Bonden und Verkapseln für die defekten oder nicht funktionstauglichen Sensorstrukturen entfällt. Außerdem bietet eine speziell entworfene miniaturisierte Durchflussmesszelle die Möglichkeit, bereits auf Waferlevel die Sensitivität, Drift, Hysterese und Ansprechzeit der (bio-)chemischen Sensoren zu charakterisieren. Das System wurde exemplarisch mit kapazitiven, pH-sensitiven EIS- (Elektrolyt-Isolator-Silizium) Strukturen und ISFET- (ionensensitiver Feldeffekttransistor) Strukturen mit verschiedenen Geometrien und Gate-Layouts getestet. Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Sensoren und Messsysteme 2010 - 15. ITG/GMA-Fachtagung, 18.05.2010 - 19.05.2010 in Nürnberg SP - 89 EP - 92 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Rysstad, Gunnar A1 - Berger, Jörg A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Realization of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Procedia Engineering N2 - A calorimetric gas sensor is presented for the monitoring of gas-phase H2O2 at elevated temperature during sterilization processes in aseptic food industry. The sensor consists of two temperature-sensitive thin-film resistances built up on a polyimide foil with a thickness of 25 μm, which are passivated with a layer of SU-8 photo resist and catalytically activated with manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilizes the elevated temperature of an evaporated H2O2 aerosol. In an experimental set-up, the sensor has shown a sensitivity of 4.78 °C/(%v/v) in a H2O2 concentration range of 0 to 10% v/v at an evaporation temperature of 240 ∘C. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied evaporation temperatures of the gas stream. The sensor characterization demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of sterilization processes. Y1 - 2010 U6 - https://doi.org/10.1016/j.proeng.2010.09.098 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 264 EP - 267 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef T1 - Real-time detection of CO by eukaryotic cells JF - Procedia Engineering N2 - In this contribution, we focus on the detection of toxic gases with living eukaryotic cells. A cell-based gas sensor system, able to measure the effects of direct exposure of gases to cells in real-time, was set up. Impedance data as well as oxygen consumption of Chinese hamster lung fibroblast cells (V79) were analysed upon exposure to carbon monoxide (CO). The CO (diluted in wet synthetic air) affects the cell respiration as indicated by an attenuated respiration signal after the CO exposure as well as an instant increase of the capacitive part of the impedance signal during the gas exposure. Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 17 EP - 20 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirchner, Patrick A1 - Spelthahn, Heiko A1 - Schöning, Michael Josef A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Friedrich, Peter A1 - Kolstad, Jens A1 - Berger, Jörg T1 - Realisierung eines Polyimid-basierten kalorimetrischen Gassensors zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllsystemen JF - Tagungsband: Sensoren und Messsysteme 2010 N2 - In aseptischen Abfüllsystemen wird Wasserstoffperoxid in der Gasphase aufgrund der stark oxidativen Wirkung zur Packstoffentkeimung eingesetzt. Dabei wird die Effizienz der Entkeimung im Wesentlichen von der vorliegenden H2O2-Konzentration im Packstoff bestimmt. Zur Inline-Überwachung der H2O2-Konzentration wurde ein kalorimetrischer Gassensor auf Basis einer flexiblen Polyimidfolie aus temperatursensitiven Dünnschicht-Widerständen und Mangan(IV)-oxid als katalytische Transducerschicht realisiert. Der Sensor weist ein lineares Ansprechverhalten mit einer Sensitivität von 7,15 °C/Vol.-% in einem H2O2-Konzentrationsbereich von 0 bis 8 Vol.-% auf. Weiterhin wurde zur Auslesung des Sensorsignals eine RFID-Elektronik, bestehend aus einem Sensor-Tag und einer Sende-/Empfangseinheit ausgelegt, sowie eine Abfolge des Messzyklus aufgestellt. Im weiteren Verlauf soll der kalorimetrische Gassensor mit der RFID-Elektronik gekoppelt und in eine Testverpackung zur Inline-Überwachung der H2O2-Konzentration in aseptischen Abfüllsystemen implementiert werden. Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Sensoren und Messsysteme 2010 - 15. ITG/GMA-Fachtagung, 18.05.2010 - 19.05.2010 in Nürnberg SP - 607 EP - 612 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schaffrath, Sophie A1 - Coppe, Thomas A1 - Rufi, Frederic A1 - Schöning, Michael Josef T1 - Development of an electrolyte-insulator-semiconductor (EIS) based capacitive heavy metal sensor for the detection of Pb2+ und Cd2+ ions JF - Physica status solidi (a) : applications and material science N2 - Chalcogenide glass materials as membranes for potentiometric sensors for chemical analysis in solutions have been studied since more than 20 years. In this work, an electrolyte–insulator–semiconductor structure was combined with chalcogenide glass membranes prepared by means of the pulsed laser deposition technique. Depending on the membrane composition a selectivity to different ions (Cd2+ and Pb2+) is achieved. The different sensor membranes have been physically characterised using microscopy, ellipsometry, profilometry, atomic force microscopy (AFM), scanning electron microscopy (SEM) and Rutherford backscattering spectrometry (RBS). The electrochemical behaviour has been investigated via capacitance/voltage (C/V) and constant capacitance (ConCap) measurements and results in a Cd2+ sensitivity of 23.1 ± 0.6 mV per decade in a linear range from 7 × 10−6 to 10−2 mol/l and 24.4 ± 0.5 mV per decade in a linear range from 5 × 10−6 to 10−2 mol/l for Pb2+, respectively. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983306 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 930 EP - 934 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Werner, Frederik A1 - Spelthahn, Heiko A1 - Schöning, Michael Josef A1 - Krumbe, Christoph A1 - Wagner, Torsten A1 - Yoshinobu, Tatsuo A1 - Keusgen, Michael T1 - Neue Ansteuerungselektronik für LAPS-basierte Biosensoren zur gleichzeitig ortsaufgelösten Messung der pH-Konzentration JF - Tagungsband: Sensoren und Messsysteme 2010 N2 - Ein lichtadressierbarer potentiometrischer Sensor (LAPS) kann die Konzentration eines oder mehrerer Analyten ortsaufgelöst auf der Sensoroberfläche nachweisen. Dazu wird mit einer modulierten Lichtquelle die Halbleiterstruktur des zu untersuchenden Bereiches angeregt und ein entsprechender Photostrom ausgelesen. Durch gleichzeitige Anregung mehrere Bereiche durch Lichtquellen mit unterschiedlichen Modulationsfrequenzen können diese auch zeitgleich ausgelesen werden. Mit der neuen, hier vorgestellten Ansteuerungselektronik integriert in einem "Field Programmable Gate Array" (FPGA) ist es möglich, mehrere Leuchtquellen gleichzeitig mit unterschiedlichen, während der Laufzeit festlegbaren Frequenzen, Phasen und Lichtintensitäten zu betreiben. Somit kann das Frequenzverhalten des Sensors untersucht und die Konzentration des Analyten über das Oberflächenpotential mit Hilfe von Strom/Spannungs-Kurven und Phase/Spannungs-Kurven bestimmt werden. Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Sensoren und Messsysteme 2010 - 15. ITG/GMA-Fachtagung, 18.05.2010 - 19.05.2010 in Nürnberg SP - 109 EP - 114 PB - VDE Verlag CY - Berlin ER -