TY - CHAP A1 - Duffner, Markus A1 - Moorkamp, Wilfried A1 - Peterson, Leif Arne A1 - Uibel, Thomas ED - Kuhlmann, Ulrike T1 - Untersuchungen zur Tragfähigkeit und Steifigkeit eines neuartigen Wandelements in Holzbauweisen T2 - Doktorandenkolloquium Holzbau Forschung + Praxis : Stuttgart, 08./09. März 2018 Y1 - 2018 SP - 131 EP - 139 PB - Universität Stuttgart, Institut für Konstruktion und Entwurf CY - Stuttgart ER - TY - RPRT A1 - Fischedick, Manfred A1 - Schoof, René A1 - Hebel, Christoph A1 - Merkens, Torsten T1 - Sektorenkopplung als Herausforderung und Chance für das Energieland NRW : Handlungsoptionen und Ergebnispapier der Expertengruppe AG 4 „Sektoren- kopplung“ im Netzwerk Netze und Speicher der EnergieAgentur.NRW im Auftrag des Landes Nordrhein-Westfalen / EnergieAgentur.NRW GmbH Y1 - 2018 ER - TY - CHAP A1 - Uibel, Thomas A1 - Moorkamp, Wilfried T1 - Geh- und Radwegbrücken in NRW - Bestandsanalyse und Perspektiven T2 - Holzbrückenbau in der Offensive : Erhaltung, Ertüchtigung, Neubauten : 5. Internationale Holzbrückentage (IHB 2018) FILharmonie Filderstadt, Filderstadt/Stuttgart (DE), 17./18. April 2018 Y1 - 2018 SN - 978-3-906226-19-4 SP - 19 EP - 32 PB - forum-holzbau CY - Biel ER - TY - CHAP A1 - Jockwer, R. A1 - Kleiber, M. A1 - Uibel, Thomas ED - Görlacher, Rainer T1 - Criteria for Evaluating the Simplification of Design Rules for Dowel-type Fasteners T2 - International Network on Timber Engineering Research, INTER : proceedings, meeting 51, 10 - 13 August 2016, Tallinn, Estonia Y1 - 2018 SP - 461 EP - 466 PB - Timber Scientific Publishing, KIT Holzbau und Baukonstruktionen CY - Karlsruhe ER - TY - JOUR A1 - Svaneborg, Carsten A1 - Karimi-Varzaneh, Hossein Ali A1 - Hojdis, Nils A1 - Fleck, Franz A1 - Everaers, Ralf T1 - Kremer-Grest Models for Universal Properties of Specific Common Polymer Species JF - Soft Condensed Matter N2 - The Kremer-Grest (KG) bead-spring model is a near standard in Molecular Dynamic simulations of generic polymer properties. It owes its popularity to its computational efficiency, rather than its ability to represent specific polymer species and conditions. Here we investigate how to adapt the model to match the universal properties of a wide range of chemical polymers species. For this purpose we vary a single parameter originally introduced by Faller and Müller-Plathe, the chain stiffness. Examples include polystyrene, polyethylene, polypropylene, cis-polyisoprene, polydimethylsiloxane, polyethyleneoxide and styrene-butadiene rubber. We do this by matching the number of Kuhn segments per chain and the number of Kuhn segments per cubic Kuhn volume for the polymer species and for the Kremer-Grest model. We also derive mapping relations for converting KG model units back to physical units, in particular we obtain the entanglement time for the KG model as function of stiffness allowing for a time mapping. To test these relations, we generate large equilibrated well entangled polymer melts, and measure the entanglement moduli using a static primitive-path analysis of the entangled melt structure as well as by simulations of step-strain deformation of the model melts. The obtained moduli for our model polymer melts are in good agreement with the experimentally expected moduli. Y1 - 2018 IS - 1606.05008 ER - TY - JOUR A1 - Altherr, Lena A1 - Leise, Philipp A1 - Pfetsch, Marc E. A1 - Schmitt, Andreas T1 - Algorithmic design and resilience assessment of energy efficient high-rise water supply systems JF - Applied Mechanics and Materials N2 - High-rise water supply systems provide water flow and suitable pressure in all levels of tall buildings. To design such state-of-the-art systems, the consideration of energy efficiency and the anticipation of component failures are mandatory. In this paper, we use Mixed-Integer Nonlinear Programming to compute an optimal placement of pipes and pumps, as well as an optimal control strategy.Moreover, we consider the resilience of the system to pump failures. A resilient system is able to fulfill a predefined minimum functionality even though components fail or are restricted in their normal usage. We present models to measure and optimize the resilience. To demonstrate our approach, we design and analyze an optimal resilient decentralized water supply system inspired by a real-life hotel building. KW - MINLP KW - Buffering Capacity KW - Uncertainty KW - Water Supply Networks KW - Booster Stations Y1 - 2018 U6 - https://doi.org/10.4028/www.scientific.net/AMM.885.211 SN - 1662-7482 VL - 885 SP - 211 EP - 223 PB - Trans Tech Publications CY - Bäch ER - TY - JOUR A1 - Ciritsis, Alexander A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Kuhl, Christiane K. A1 - Kraemer, Nils Andreas T1 - Porosity and tissue integration of elastic mesh implants evaluated in vitro and in vivo JF - Journal of Biomedical Materials Research: Part B: Applied Biomaterials N2 - Purpose In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model. Material and Methods Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio). Results In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF. Conclusion The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018. Y1 - 2018 U6 - https://doi.org/10.1002/jbm.b.33877 SN - 1552-4981 VL - 106 IS - 2 SP - 827 EP - 833 PB - Wiley CY - New York, NY ER - TY - BOOK A1 - Jochim, Haldor E. A1 - Lademann, Frank T1 - Planung von Bahnanlagen: Grundlagen - Planung - Berechnung Y1 - 2018 SN - 978-3-446-44220-7 U6 - https://doi.org/10.3139/9783446448940 PB - Fachbuchverlag Leipzig im Carl Hanser Verlag CY - München ET - 2., aktualisierte und erweiterte Auflage ER - TY - JOUR A1 - de Blois, Eric A1 - de Zanger, Rory M. S. A1 - Paulßen, Elisabeth A1 - Sze Chan, Ho A1 - Breeman, Wouter A. P. T1 - Semi-automated system for concentrating 68Ga-eluate to obtain high molar and volume concentration of 68Ga-Radiopharmaca for preclinical applications JF - Nuclear Medicine and Biology N2 - 68Ga-radiopharmaceuticals are common in the field of Nuclear Medicine to visualize receptor-mediated processes. In contrast to straightforward labeling procedures for clinical applications, preclinical in vitro and in vivo applications are hampered for reasons like e.g. volume restriction, activity concentration, molar activity and osmolality. Therefore, we developed a semiautomatic system specifically to overcome these problems. A difficulty appeared unexpectedly, as intrinsic trace metals derived from eluate (Zn, Fe and Cu) are concentrated as well in amounts that influence radiochemical yield and thus lower molar activity. Y1 - 2018 U6 - https://doi.org/10.1016/j.nucmedbio.2018.06.006 VL - 64-65 SP - 16 EP - 21 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Schmidts, Oliver A1 - Kraft, Bodo A1 - Schreiber, Marc A1 - Zündorf, Albert T1 - Continuously evaluated research projects in collaborative decoupled environments T2 - 2018 ACM/IEEE 5th International Workshop on Software Engineering Research and Industrial PracticePractice, May 29, 2018, Gothenburg, Sweden : SER&IP' 18 N2 - Often, research results from collaboration projects are not transferred into productive environments even though approaches are proven to work in demonstration prototypes. These demonstration prototypes are usually too fragile and error-prone to be transferred easily into productive environments. A lot of additional work is required. Inspired by the idea of an incremental delivery process, we introduce an architecture pattern, which combines the approach of Metrics Driven Research Collaboration with microservices for the ease of integration. It enables keeping track of project goals over the course of the collaboration while every party may focus on their expert skills: researchers may focus on complex algorithms, practitioners may focus on their business goals. Through the simplified integration (intermediate) research results can be introduced into a productive environment which enables getting an early user feedback and allows for the early evaluation of different approaches. The practitioners’ business model benefits throughout the full project duration. Y1 - 2018 SP - 1 EP - 9 PB - ACM CY - New York, NY ER -