TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Brökel, M. A1 - Fuss, L. A1 - Larue, H. A1 - Parl, C. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - The ClearPET data acquisition JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - Within the Crystal Clear Collaboration a modular system for a small animal PET scanner (ClearPET™) has been developed. The modularity allows the assembly of scanners of different sizes and characteristics in order to fit the specific needs of the individual member institutions. Now a first demonstrator is being completed in Julich. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to multi-channel photomultipliers (PMTs). A free-running ADC digitizes the signal from the PMT and the complete scintillation pulses are sampled by an FPGA and sent with 20 MB/S to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. An advantage of that is that the coincidence window and the dimensions of the field of view can be adjusted easily. The ClearPET™ demonstrator is equipped with 10240 crystals on 80 PMTs. This paper presents an overview of the data acquisition system. Y1 - 2004 SN - 1082-3654 SP - 3097 EP - 3100 ER - TY - JOUR A1 - Christ, D. A1 - Hollendung, A. A1 - Larue, H. A1 - Parl, C. A1 - Streun, M. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. T1 - Homogenization of the MultiChannel PM gain by inserting light attenuating masks JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - MultiChannel Photomultipliers (PM), like the R7600-00-M64 or R5900-00-M64 from Hamamatsu, are often chosen as photodetectors in high-resolution positron emission tomography (PET). A major problem of this PM is the nonuniform channel gain. In order to solve this problem, light attenuating masks were created. The aim of the masks is a homogenization of the output of all 64 channels using different hole sizes at the channel positions. The hole area, which is individually defined for the different channels, is inversely proportional to the channel gain. The measurements by inserting light attenuating masks improved a homogenization to a ratio of 1:1.2. Y1 - 2004 SN - 1082-3654 SP - 2382 EP - 2385 ER - TY - JOUR A1 - Ziemons, Karl A1 - Heinrichs, U. A1 - Streun, M. A1 - Pietrzyk, U. T1 - Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. Y1 - 2004 SN - 1082-3654 SP - 3053 EP - 3056 ER - TY - JOUR A1 - Auffray, E. A1 - Bruyndonckx, P. A1 - Devroede, O. A1 - Fedorov, A. A1 - Ziemons, Karl T1 - The ClearPET project JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view. Y1 - 2004 SN - 0168-9002 N1 - Proceedings of the 2nd International Conference on Imaging Technologies in Biomedical Sciences VL - 527 IS - 1-2 SP - 171 EP - 174 ER - TY - JOUR A1 - Streun, M. A1 - Christ, D. A1 - Hellendung, A. A1 - Larue, H. A1 - Ziemons, Karl A1 - Halling, H. T1 - Effects of crosstalk and gain nonuniformity using multichannel PMTs in the Clearpet® scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 402 EP - 405 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. A1 - Bruyndonckx, P. T1 - The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view. Preliminary data shows a correct identification of the crystal layer about (98±1)%. Typically the energy resolution is (23.3±0.5)% for the luyap layer and (15.4±0.4)% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 307 EP - 311 ER - TY - JOUR A1 - Beer, S. A1 - Streun, M. A1 - Hombach, T. A1 - Buehler, J. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants JF - Physics in Medicine and Biology N2 - Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements. Y1 - 2010 U6 - https://doi.org/10.1088/0031-9155/55/3/006 SN - 1361-6560 VL - 55 IS - 3 SP - 635 EP - 646 PB - IOP CY - Bristol ER - TY - JOUR A1 - Herzog, Hans A1 - Pietrzyk, Uwe A1 - Shah, N. Jon A1 - Ziemons, Karl T1 - The current state, challenges and perspectives of MR-PET JF - Neuroimage N2 - Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization. Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop. Y1 - 2010 U6 - https://doi.org/10.1016/j.neuroimage.2009.10.036 SN - 1053-8119 VL - 49 IS - 3 SP - 2072 EP - 2082 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Parl, C. A1 - Larue, H. A1 - Streun, M. A1 - Ziemons, Karl T1 - Double-side-readout technique for SiPM-matrices JF - 2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit. Y1 - 2011 SN - 1095-7863 SP - 1486 EP - 1487 PB - IEEE CY - New York ER - TY - JOUR A1 - Gebhardt, Andreas A1 - Fateri, Miranda T1 - 3D printing and its applications JF - RTejournal - Forum für Rapid Technologie N2 - Eine zunehmende Anzahl von Artikeln in Publikumszeitschriften und Journalen rückt die direkte Herstellung von Bauteilen und Figuren immer mehr in das Bewusstsein einer breiten Öffentlichkeit. Leider ergibt sich nur selten ein einigermaßen vollständiges Bild davon, wie und in welchen Lebensbereichen diese Techniken unseren Alltag verändern werden. Das liegt auch daran, dass die meisten Artikel sehr technisch geprägt sind und sich nur punktuell auf Beispiele stützen. Dieser Beitrag geht von den Bedürfnissen der Menschen aus, wie sie z.B. in der Maslow’schen Bedürfnispyramide strukturiert dargestellt sind und unterstreicht dadurch, dass 3D Printing (oder Additive Manufacturing resp. Rapid Prototyping) bereits alle Lebensbereiche erfasst hat und im Begriff ist, viele davon zu revolutionieren. N2 - An increasing amount of popular articles focus on making models and sculptures by 3D Printing thus making more and more even private users aware of this technology. Unfortunately they mostly draw an incomplete picture of how our daily life will be influenced by this new technology. Often this is caused by a very technical point of view based on not very representative examples. This article focuses on the peoples needs as they have been structured by the so-called Maslow pyramid. Doing so, it underlines that 3D Printing (called Additive Manufacturing or Rapid Prototyping as well) already touches all aspects of life and is about to revolutionize most of them. Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0009-2-35626 SN - 1614-0923 VL - 10 IS - 1 PB - Fachhochschule Aachen CY - Aachen ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Suso, Henri-Pierre A1 - Rysstad, Gunnar A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes JF - Physica status solidi (a) N2 - A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests. KW - calorimetric gas sensor;hydrogen peroxide;wireless sensor system Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200920 SN - 1862-6319 VL - 210 IS - 5 SP - 877 EP - 883 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chatziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different MicroCT scanner configurations by GEANT4 simulations JF - IEEE Transactions on Nuclear Science N2 - This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2005 SN - 0018-9499 VL - 52 IS - 1 SP - 188 EP - 192 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - The data acquisition system of ClearPET neuro - a small animal PET scanner JF - IEEE Transactions on Nuclear Science N2 - The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 3 SP - 700 EP - 703 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Weber, S. A1 - Streun, M. A1 - Parl, C. A1 - Ziemons, Karl T1 - High resolution imaging with ClearPET™ Neuro - first animal images JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance. Y1 - 2006 SN - 1082-3654 SP - 1641 EP - 1644 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - Timemark correction for the ClearPET™ scanners JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented Y1 - 2006 SN - 1082-3654 SP - 2057 EP - 2060 ER - TY - JOUR A1 - Jens, Otto A1 - Kaldenhoff, E. A1 - Kirschner-Hermanns, R. A1 - Mühl, Thomas A1 - Klinge, Uwe T1 - Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates JF - Journal of biomedical materials research. Part A N2 - Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome. Y1 - 2014 U6 - https://doi.org/10.1002/jbm.a.34767 SN - 1552-4965 VL - 102 IS - 4 SP - 1079 EP - 1084 PB - Wiley CY - New York ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Ichimura, Hiroki A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel JF - Sensors and actuators. B: Chemical N2 - The chemical imaging sensor is a device to visualize the spatial distribution of chemical species based on the principle of LAPS (light-addressable potentiometric sensor), which is a field-effect chemical sensor based on semiconductor. In this study, the chemical imaging sensor has been applied to investigate the ion profile of laminar flows in a microfluidic channel. The chemical images (pH maps) were collected in a Y-shaped microfluidic channel while injecting HCl and NaCl solutions into two branches. From the chemical images, it was clearly observed that the injected solutions formed laminar flows in the channel. In addition, ion diffusion across the laminar flows was observed, and the diffusion coefficient could be derived by fitting the pH profiles to the Fick's equation. Y1 - 2013 U6 - https://doi.org/10.1016/j.snb.2013.04.057 SN - 1873-3077 (E-Journal); 0925-4005 (Print) N1 - Part of special issue "Selected Papers from the 26th European Conference on Solid-State Transducers" VL - 189 SP - 240 EP - 245 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Trattner, Barbara A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Stütz, Evamaria A1 - Schmitt-Landsiedel, Doris A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment JF - Sensors and actuators. B: Chemical Y1 - 2013 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - Vol. 182 SP - 58 EP - 65 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Meliß, Michael A1 - Neskakis, A. A1 - Plettner-Marliani, J. A1 - Lange, C. A1 - Hövelmann, A. A1 - Schumacher, J. T1 - Waste water recycling supplied by renewable energies : basic conditions and possible treatment technologies JF - Renewable energy. Vol. 14 (1998), iss. 1-4. 6th Arab International Solar Energy Conference: Bringing Solar Energy into the Daylight, Muscat, Sultanate of Oman, 29.03.-01.04.1998 Y1 - 1998 SN - 1879-0682 (E-Book); 0960-1481 (Print) SP - 325 EP - 331 ER - TY - JOUR A1 - Wemhöner, Carsten A1 - Hafner, Bernd A1 - Schwarzer, Klemens T1 - Simulation of solar thermal systems with CARNOT blockset in the environment MATLAB-Simulink Y1 - 2000 SP - 1 EP - 6 ER - TY - JOUR A1 - Vitusevich, S. A. A1 - Förster, Arnold A1 - Lüth, H. A1 - Belyaev, A. E. A1 - Danylyuk, S. V. A1 - Konakova, R. V. A1 - Sheka, D. I. T1 - Resonant spectroscopy of electric-field-induced superlattices JF - Journal of Applied Physics. 90 (2001), H. 6 Y1 - 2001 SN - 1089-7550 U6 - https://doi.org/10.1063/1.1392956 SP - 2857 EP - 2861 ER - TY - JOUR A1 - Stock, J. A1 - Malindretos, J. A1 - Indlekofer, K.M. A1 - Pöttgens, Michael A1 - Förster, Arnold A1 - Lüth, Hans T1 - A Vertical Resonant Tunneling Transistor for Application in Digital Logic Circuits JF - IEEE Transactions on Electron Devices (T-ED). 48 (2001), H. 6 Y1 - 2001 SN - 0018-9383 SP - 1028 EP - 1032 ER - TY - JOUR A1 - Schwarzer, Klemens A1 - Schlenger, Barbara J. T1 - Investigation of fission product aerosol behavior in an HTR containment during severe core-heatup accidents / Barbara J. Schlenger ; K. Schwarzer JF - Tagungsbericht : Maritim Kongresszentrum, 17. - 19. Mai '88 Travemünde / Kerntechnische Gesellschaft e.V.; Deutsches Atomforum e.V. [Red.: K. G. Bauer] Y1 - 1988 SN - 0720-9207 N1 - Jahrestagung Kerntechnik <1988, Lübeck-Travemünde> ; Annual Meeting of Nuclear Technology <1988, Lübeck-Travemünde> SP - 179 EP - 182 PB - Inforum CY - Bonn ER - TY - JOUR A1 - Hodel, U. A1 - Orzati, A. A1 - Marso, M. A1 - Homann, O. A1 - Fox, A. A1 - Hart, A. v. d. A1 - Förster, Arnold A1 - Kordos, P. A1 - Lüth, H. T1 - A novel InAlAs/InGaAs layer structure for monolithically integrated photoreceiver JF - Conference Proceedings: 2000 International Conference on Indium Phosphide and related materials Y1 - 2000 SN - 0-7803-6320-5 N1 - International Conference on Indium Phosphide and Related Materials <12, 2000, Williamsburg, Va.> SP - 466 EP - 469 PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Hoskens, R.C.P. A1 - Roer, T.G. van de A1 - Tolstikhin, V.I. A1 - Förster, Arnold T1 - Hot electron injection laser: vertically integrated transistor-laser structure for high-speed, low-chirp direct modulation JF - LEOS 2000 : 2000 IEEE annual meeting conference proceedings; 13th annual meeting; IEEE Lasers and Electro-Optics Society 2000 annual meeting; 13-16 November 2000, The Westin Rio Mar Beach, Rio Grande, Puerto Rico. Vol. 2 Y1 - 2000 SN - 0-7803-5947-X N1 - 2000 IEEE LEOS annual meeting SP - 444 EP - 445 PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Hoskens, R. C. P. A1 - Tolstikhin, V.I. A1 - Förster, Arnold A1 - Roer, T.G. van de T1 - Vertically integrated transistor-laser structure, take 2 JF - WOCSDICE 2000, 24th Workshop on Compound Semiconductor Devices and Integrated Circuits held in Europe : May 29 - June 02, 2000, Aegean Sea, Greece. Y1 - 2000 SN - 0970311109 N1 - WOCSDICE ; (24, 2000) Workshop on Compound Semiconductor Devices and Integrated Circuits held in Europe ; (24 : ; 2000.05.29-06.02) PB - Univ. of Michigan CY - Ann Arbor, Mich. ER - TY - JOUR A1 - Darmo, J. A1 - Schäffer, F. A1 - Förster, Arnold A1 - Kordos, P. T1 - Beryllium doped low-temperature-grown MBE GaAs: material for photomixing in the THz frequency range JF - ASDAM 2000 : conference proceedings / edited by Jozef Osvald ... [et al.] Y1 - 2000 SN - 0780359399 N1 - International Conference on Advanced Semiconductor Devices and Microsystems ; (3rd : ; 2000 : ; Smolenice, Slovakia) SP - 147 EP - 150 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Griebel, M. A1 - Indlekofer, K.M. A1 - Lüth, H. T1 - Single electron transport in resonant tunnelling diodes laterally confined by ion implantation. Griebel, M.; Indlekofer, K.M.; Förster, A.; Lüth, H. JF - Journal of Physics D: Applied Physics. 32 (1999), H. 14 Y1 - 1999 SN - 1361-6463 SP - 1729 EP - 1733 ER - TY - JOUR A1 - Schmidt, R. A1 - Tonnesmann, A. A1 - Förster, Arnold A1 - Grimm, M. A1 - Kordos, P. A1 - Lüth, H. T1 - Metamorphic InAlAs/InGaAs HEMT's on GaAs substrates using an InP buffer layer JF - 8th IEEE International Symposium on High Performance Electron Devices for Microwave and Optoelectronic Applications : EDMO 2000 ; [13 - 14 November 2000, University of Glasgow] / organised by Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow Scotland. MTT/ED/AP/LEO Societies Joint Chapter, United Kingdom and Republic of Ireland Section. With technical co-sponsorship from IEEE Electron Device Society Y1 - 2000 SN - 0-7803-6550-X N1 - EDMO <8, 2000, Glasgow> ; University / Department of Electronics and Electrical Engineering ; IEEE catalog number 00TH8534 SP - 95 EP - 98 PB - IEEE Operations Center CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Betko, J. A1 - Morvic, M. A1 - Novak, J. T1 - Magnetoresistance in low-temperature grown molecular-beam epitaxial GaAs. Betko, J.; Morvic, M.; Novak, J.; Förster, A.; Kordos, P. JF - Journal of Applied Physics. 86 (1999), H. 11 Y1 - 1999 SN - 1089-7550 SP - 6243 EP - 6248 ER - TY - JOUR A1 - Förster, Arnold A1 - Morvic, M. A1 - Betko, J. A1 - Novak, J. T1 - Characterization of low-temperature GaAs by conductivity, Hall effect and magnetoresistance measurements. Morvic, M., Betko, J.; Novak, J.; Förster, A.; Kordos, P. JF - 2nd Symposium on Non-Stoichiometric III-V Compounds : [4th - 6th October 1999, Erlangen] / [ed. by T. Marek ...] Friedrich-Alexander-Universität Erlangen-Nürnberg Y1 - 1999 SN - 3-932392-19-1 N1 - Symposium on Non-Stoichiometric III-V Compounds <2, 1999, Erlangen> SP - 79 EP - 85 PB - Lehrstuhl für Mikrocharakterisierung CY - Erlangen ER - TY - JOUR A1 - Förster, Arnold A1 - Kordos, P. A1 - Marso, M. A1 - Rüders, F. T1 - 550 GHz bandwidth photodetector on low-temperature grown molecular-beam epitaxial GaAs. Kordos, P., Förster, A.; Marso, M.; Rüders, F. JF - Electronics Letters. 34 (1998), H. 1 Y1 - 1998 SN - 1350-911X SP - 119 EP - 120 ER - TY - JOUR A1 - Vitusevich, S. A. A1 - Förster, Arnold A1 - Reetz, W. A1 - Lüth, H. A1 - Belyaev, A. E. A1 - Danylyuk, S. V. T1 - Fine structure of photoresponse spectra in a double-barrier resonant tunnelling diode JF - Nanotechnology. 11 (2000), H. 4 Y1 - 2000 SN - 1361-6528 SP - 305 EP - 308 ER - TY - JOUR A1 - Fredebeul-Krein, Markus A1 - Vogel, Erika T1 - Underground Storage Facilities in the German natural gas market: A need for access regulation to ensure competition? JF - Zeitschrift für Energiewirtschaft. 30 (2006), H. 4 Y1 - 2006 SN - 0343-5377 SP - 257 EP - 270 ER - TY - JOUR A1 - Förster, Arnold A1 - Hartmann, A. A1 - Dieker, Ch. A1 - Hollfelder, M. T1 - Spontaneous formation of tilted AlGaAS/GaAs superlattice during AlGaAs growth. Hartmann, A.; Dieker, Ch.; Hollfelder, M.; Hardtdegen, H.; Förster, A.; Lüth, H. JF - Applied Surface Science. 123-124 (1998) Y1 - 1998 SN - 0169-4332 N1 - = Proceedings of the Sixth International Conference on the Formation of Semiconductor Interfaces SP - 704 EP - 709 ER - TY - JOUR A1 - Schwarzer, Klemens A1 - Werner, M. A1 - Hartz, T. T1 - Lacasa - an instrument for the energy analysis and optimisation of buildings including technical equipment JF - Proceedings / organised by: ISES Europe ... [Ed.: Deutsche Gesellschaft für Sonnenenergie e.V. - DGS, Munich ; PSE GmbH - Forschung Entwicklung Marketing, Freiburg]. - Vol. 2 Y1 - 2004 SN - 3-9809656-2-7 N1 - EuroSun <5, 2004, Freiburg, Breisgau> ; Internationales Sonnenforum <14, 2004, Freiburg, Breisgau> ; Deutsche Gesellschaft für Sonnenenergie ; CD-ROM-Ausg.: ISBN 3-9809656-4-3 SP - 2-489-2-494 PB - PSE CY - Freiburg [Breisgau] ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Kayatekin, Muammer B. A1 - Uysal, N. A1 - Resmi, H. T1 - Does antioxidant supplementation alter the effects of acute exercise on erythrocyte aggregation, deformability and endothelium adhesion in untrained rats? Kayatekin, Muammer B.; Uysal N.; Resmi, H.; Bediz, Seref C.; Temiz Artmann, A.; Genç, S.; Tugyan, K. JF - International Journal for Vitamin and Nutrition Research. 75 (2005), H. 4 Y1 - 2005 SN - 0300-9831 SP - 243 EP - 250 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Resmi, Halil A1 - Akhunlar, Hülya A1 - Güner, Gül T1 - In vitro effects of high glucose concentrations on membrane protein sulfhydryl oxidation, G-actin and deformability of human erythrocytes. Resmi, Halil ; Akhunlar, Hülya ; Temiz Artmann, Aysegül ; Güner, Gül JF - Cell biochemistry and function. 23 (2005), H. 3 Y1 - 2005 SN - 0263-6484 SP - 163 EP - 168 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Cavdar, C. A1 - Yenicerioglu, Y. A1 - Caliskan, S. T1 - The effects of intravenous iron treatment on oxidant stress and erythrocyte deformability in haemodialysis patients. Cavdar, C.; Temiz, A.; Yenicerioglu, Y.; Caliskan, S.; Celik, A.; Sifil, A.; Onvural, B.; Camsari, T. JF - Scandinavian Journal of Urology and Nephrology. 37 (2003), H. 1 Y1 - 2003 SN - 0036-5599 SP - 77 EP - 82 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Yalcin, Ozlem A1 - Resmi, Halil A1 - Baskurt, Oguz K. T1 - Can white blood cell activation be one of the major factors that affect hemorheological parameters during and after exercise? JF - Clinical Hemorheology and Microcirculation. 26 (2002), H. 3 Y1 - 2002 SN - 1386-0291 N1 - = The 11th European Symposium on Clinical Hemorheology, Rouen, France, 19-22 September 2000 SP - 189 EP - 193 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, Oguz K. A1 - Pekcetin, C. A1 - Kandemir, F. T1 - Leukocyte activation, oxidant stress and red blood cell properties after acute, exhausting exercise in rats. Temiz, A.; Baskurt, O. K., Pekcetin, C.; Kandemir, F.; Güre, A. JF - Clinical Hemorheology and Microcirculation. 22 (2000), H. 4 Y1 - 2000 SN - 1386-0291 SP - 253 EP - 259 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Yolcuoglu, B. A1 - Onal, M. A. A1 - Sipahi, O. T1 - The effect of skin transplantation on tumour growth in mice. Yolcuoglu, B.; Onal, M. A.; Sipahi, O.; Temiz, A.; Pekcetin, C.; Acikgöz, O.; Kar, H.; Güre A. JF - The American Journal of Surgery. 178 (1999), H. 4 Y1 - 1999 SN - 0002-9610 SP - 329 EP - 330 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Ates, H. A1 - Üretmen, Ö. A1 - Andac, K. T1 - Erythrocyte deformability in high-tension and normal tension glaucoma. Ates, H.; Üretmen, Ö.; Temiz, A.; Andac, K. JF - International Ophthalmology. 22 (1998), H. 1 Y1 - 1998 SN - 0165-5701 SP - 7 EP - 12 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Meiselman, H. J. T1 - Effect of superoxide anions on red blood cell rheologic properties. Baskurt, O. K.; Temiz, A.; Meiselman, H. J. JF - Free Radical Biology and Medicine. 24 (1998), H. 1 Y1 - 1998 SN - 0891-5849 SP - 102 EP - 110 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Meiselman, H. J. T1 - Red blood cell aggregation in experimental sepsis . Baskurt, O. K.; Temiz, A.; Meiselman, H. J. JF - Journal of Laboratory and Clinical Medicine. 130 (1997), H. 2 Y1 - 1997 SN - 0022-2143 SP - 183 EP - 190 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Edremitlioglu, M. T1 - Effect of erythrocyte deformability on myocardial hematocrit gradient. Baskurt, O.K.; Edremitlioglu, M.; Temiz, A. JF - American Journal of Physiology: Heart and Circulatory Physiology. 268 (1995), H. 1 Y1 - 1995 SN - 0363-6135 SP - 260 EP - 264 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Edremitlioglu, M. T1 - In vitro effects of in vivo activated leukocytes on red blood cell filterability and lipid peroxidation. Baskurt, O.K.; Edremitlioglu, M.; Temiz, A. JF - Clinical Hemorheology. 14 (1994), H. 4 Y1 - 1994 SP - 591 EP - 596 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Akhisaroglu, M. A1 - Sercan, Z. A1 - Kayatekin, B. M. T1 - Adhesion of Erythrocytes to Endothelial Cells After Acute Exercise: Differences in Red Blood Cells from Juvenile and Adult Rats. Temiz Artmann, A.; Akhisaroglu, M.; Sercan, Z.; Kayatekin, BM.; Yorukoglu, K.; Kirkali, G. JF - Physiological Research (2005) Y1 - 2005 SN - 0862-8408 N1 - pre-press article ER - TY - JOUR A1 - Thielemann, Frank A1 - Bock, Jürgen T1 - Organization and management of German-Russian joint ventures. Bock, Jürgen; Thielemann, Frank JF - International journal of technology management. 9 (1994), H. 8 Y1 - 1994 SN - 0267-5730 SP - 864 EP - 879 ER - TY - JOUR A1 - Förster, Arnold A1 - Bertuccio, G. A1 - Pullia, A. T1 - Pixel X-ray detectors in epitaxial gallium arsenide withhigh-energy resolution capabilities (Fano factor experimentaldetermination) / G. Bertuccio ; A. Pullia ; J. Lauter ; A. Förster ... JF - IEEE transactions on nuclear science. 44 (1997), H. 1 Y1 - 1997 SN - 0018-9499 SP - 1 EP - 5 ER - TY - JOUR A1 - Förster, Arnold A1 - Morvic, M. A1 - Betko, J. T1 - On the hopping and band conductivity in molecular-beam epitaxial low-temperature grown GaAs / M. Morvic ; J. Betko ; J. Novák ... A. Förster JF - Physica status solidi / B, Basic research. 205 (1998), H. 1 Y1 - 1998 SN - 1521-3951 SP - 125 EP - 128 ER - TY - JOUR A1 - Fredebeul-Krein, Markus T1 - Adopting a coherent institutional framework for the Ukrainian telecom sector: Lessons to be learnt from European and German experience JF - Zerkalo Nedeli (2003) Y1 - 2003 N1 - (Ukrainian Journal) ER - TY - JOUR A1 - Fredebeul-Krein, Markus T1 - Regulating Prices of Unbundled Access to the Local Loop: A German Case Study JF - Telekomunikacja i techniki informacyjne (2002) Y1 - 2002 SN - 1640-1549 N1 - Telecommunications and Information Technologies SP - 10 EP - 18 ER - TY - JOUR A1 - Förster, Arnold A1 - Brugger, H. A1 - Meiners, U. T1 - High quality GaAs-based resonant tunneling diodes for high frequency device applications / H. Brugger ; U. Meiners ; C. Wölk ... A. Förster ... JF - Proceedings : August 5 - 7, 1991, Cornell University, Ithaca, New York / R. J. Trew, General Chairman Y1 - 1991 SN - 0-7803-0491-8 N1 - Cornell Conference on Advanced Concepts in High Speed Semiconductor Devices and Circuits <1991, Ithaca, NY> SP - 39 EP - ff. PB - Inst. of Electrical and Electronics Engineers CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Dubecky, F.. A1 - Darmo, J. T1 - Investigation of deep-level states in bulk and low temperature MBE semiinsulating GaAs by admittance transient spectroscopy / F. Dubecky ; J. Darmo ; M. Darviras ; A. Förster ... JF - Semi-insulating III-V materials, Ixtapa, Mexico 1992 : proceedings of the 7th Conference on Semi-insulating III-V Materials, Ixtapa, Mexico, 21 - 24 April 1992 / ed. by C. J. Miner ... Y1 - 1994 SN - 0-7503-0242-9 N1 - Conference on Semi-Insulating III-V Materials <7, 1992, Ixtapa> SP - 265 EP - 272 PB - Inst. of Physics Publ. CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Dieker, C. A1 - Gerthsen, D. T1 - Microstructure of the AlAs/GaAs and AlAs/InGaAs resonant tunneling diodes and its correlation with the electrical properties / C. Dieker ; D. Gerthsen ; A. Förster ... JF - Microscopy of semiconducting materials 1993 : proceedings of the Royal Microscopical Society Conference held at Oxford University, 5 - 8 April 1993 / ed. by A. G. Cullis ... - (Conference series / Institute of Physics ; 134) Y1 - 1993 SN - 0-7503-0290-9 N1 - Royal Microscopical Society Conference on Microscopy of Semiconducting Materials <8, 1993, Oxford> ; MSM <8, 1993, Oxford> SP - 253 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Walther, T. A1 - Gerthsen, D. A1 - Carius, Reinhard A1 - Förster, Arnold T1 - AlAs/GaAs Quantum well structures: Interface properties investigated by high-resolution transmission electron microscopy and photoluminescence spectroscopy / T. Walther ; D. Gerthsen ; R. Carius ; A. Förster ... JF - Microscopy of semiconducting materials 1993 : proceedings of the Royal Microscopical Society Conference held at Oxford University, 5 - 8 April 1993 / ed. by A. G. Cullis ... - (Conference series / Institute of Physics ; 134) Y1 - 1993 SN - 0-7503-0290-9 N1 - Royal Microscopical Society Conference on Microscopy of Semiconducting Materials <8, 1993, Oxford> ; MSM <8, 1993, Oxford> SP - 449 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Kordos, P. A1 - Betko, J. T1 - Electrical and structural characterization of MBE GaAs grown at temperatures between 200 and 600 °C / P. Kordos ; J. Betko; A. Förster ... JF - Compound semiconductors, 1994 : proceedings of the twenty-first International Symposium on Compound Semiconductors held in San Diego, California, 18 - 22 September, 1994 / ed. by Herb Goronkin ... - (Conference series / Institute of Physics ; 141) Y1 - 1995 SN - 0-7503-0226-7 N1 - International Symposium on Compound Semiconductors <21, 1994, San Diego, Calif.> ; Institute of Physics SP - 295 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Hardtdegen, Hilde A1 - Ungermanns, C. T1 - Comparative investigation of electrical and optical characteristics of AlxGa1-xAs/GaAs structures deposited by LP-MOVPE and MBE / H. Hardtdegen ; M. Hollfelder ; C. Ungermanns ... A. Förster ... JF - Compound semiconductors, 1994 : proceedings of the twenty-first International Symposium on Compound Semiconductors held in San Diego, California, 18 - 22 September, 1994 / ed. by Herb Goronkin ... - (Conference series / Institute of Physics ; 141) Y1 - 1995 SN - 0-7503-0226-7 N1 - International Symposium on Compound Semiconductors <21, 1994, San Diego, Calif.> ; Institute of Physics SP - 81 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Tillmann, K. A1 - Gerthsen, D. T1 - Morphological transformations of MBE-grown In0.6Ga0.4As island on GaAs(001) substrates / K. Tillmann ; D. Gerthsen ; P. Pfundstein ; A. Förster ... JF - Microscopy of semiconducting materials 1995 : proceedings of the Institute of Physics Conference held at Oxford University, 20 - 23 March 1995 / Ed. by A G Cullis ... - (Conference series / Institute of Physics ; 146) Y1 - 1995 SN - 0-7503-0347-6 N1 - MSM <9, 1995, Oxford> ; Institut of Physics SP - 195 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Lauter, J. A1 - Lüth, H. T1 - AlGaAs/GaAs avalanche detector array -1 GBit/s X-ray receiver for timing measurements / J. Lauter ; A. Förster ; H. Lüth ... JF - 1995 IEEE conference record : October 21 - 28, 1995, San Francisco / Patricia A. Moonier, guest ed. - Vol. 1 Y1 - 1996 SN - 0-7803-3180-X N1 - Nuclear Science Symposium <1995, San Francisco, Calif.> ; Medical Imaging Conference <1995, San Francisco, Calif.> ; IEEE catalog number: 95CH35898 SP - 579 EP - ff. PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Lentzen, M. A1 - Gerthsen, D. T1 - Strain relaxation of lattice-mismatched In0.2Ga0.8As/GaAs superlattices on GaAs(001) substrates / M. Lentzen ; D. Gerthsen ; A. Förster ... JF - Microscopy of semiconducting materials 1995 : proceedings of the Institute of Physics Conference held at Oxford University, 20 - 23 March 1995 / Ed. by A G Cullis ... - (Conference series / Institute of Physics ; 146) Y1 - 1995 SN - 0-7503-0347-6 N1 - MSM <9, 1995, Oxford> ; Institut of Physics SP - 357 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Rose, D. A1 - Pietsch, U. A1 - Metzger, T. H. T1 - Depth resolved investigations of the relaxation behaviour in strained GaInAs/GaAs superlattices using grazing incidence X-ray diffraction / Rose, D. ; Pietsch, U. ; Förster, A. ; Metzger, T. H. JF - Nuclear instruments and methods in physics research / Section B, Beam interactions with materials and atoms. 97 (1995), H. 1-4 Y1 - 1995 SN - 0168-583X SP - 333 EP - 336 ER - TY - JOUR A1 - Förster, Arnold A1 - Rosenauer, A. A1 - Remmele, T. T1 - Strain determination in mismatched semiconductor heterostructures by the digital analysis of lattice images / A. Rosenauer ; T. Remmele ; U. Fischer ; A. Förster ... JF - Microscopy of semiconducting materials 1997 : proceedings of the Royal Microscopical Society Conference held at Oxford University, 7 - 10 April 1997 / ed. by A. G. Cullis ... - (Conference series / Institute of Physics ; 157) Y1 - 1997 SN - 0-7503-0464-2 N1 - MSM <10, 1997, Oxford> ; Conference on Microscopy of Semiconducting Materials <10, 1997, Oxford> ; Institut of Physics SP - 39 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Schmidt, T. A1 - Haug, R. J. T1 - Imaging the local density of states in a disordered semiconductor / T. Schmidt ; R. J. Haug ; V. I. Fal'ko ... A. Förster ... JF - 23rd International Conference on the Physics of Semiconductors : Berlin, Germany, July 21 - 26, 1996 / ed.: Matthias Scheffler ... - Vol. 3 Y1 - 1996 SN - 981-02-2947-X N1 - International Conference on the Physics of Semiconductors <23, 1996, Berlin> SP - 2251 EP - ff. PB - World Scientific CY - Singapore [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Kordos, P. A1 - Ruders, F. T1 - Properties of LT MBE GaAs for photomixing up to THz frequencies / P. Kordos ; F. Ruders ; M. Marso ; A. Förster JF - Proceedings : 8 - 11 December 1996, Australian National University, Canberra, Australia / ed.: C. Jagadish Y1 - 1997 SN - 0-7803-3374-8 N1 - Conference on Optoelectronic and Microelectronic Materials and Devices <1996, Canberra> ; IEEE catalog number: 96TH8197 SP - 71 EP - ff. PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Hu, Quing A1 - Verghese, S. T1 - High-frequency (f ~ 1 THz) studies of quantum-effect devices / Qing Hu ; S. Verghese ; R. A. Wyss ... A. Förster JF - Semiconductor science and technology. 11 (1996), H. 12 Y1 - 1996 SN - 1361-6641 SP - 1888 EP - 1894 ER - TY - JOUR A1 - Förster, Arnold A1 - Schmidt, T. A1 - Haug, R. J. T1 - Spectroscopy of local density of states fluctuations in a disordered conductor / T. Schmidt ; R. J. Haug ; V. I. Fal'ko ... A. Förster ... JF - Europhysics letters. 36 (1996), H. 1 Y1 - 1996 SN - 1286-4854 SP - 61 EP - 66 ER - TY - JOUR A1 - Förster, Arnold A1 - Tillmann, K. A1 - Thust, M. T1 - Determination of segregation, elastic strain and thin-foil relaxation in InxGa-1-x As islands on GaAs(001) by high resolution transmission electron microscopy / K. Tillmann ; A. Thust ; M. Lentzen ... A. Förster ... JF - Philosophical magazine / Letters. 74 (1996), H. 5 Y1 - 1996 SN - 1362-3036 SP - 309 EP - 315 ER - TY - JOUR A1 - Förster, Arnold A1 - Lauter, J. A1 - Lüth, H. T1 - AlGaAs/GaAs avalanche detector array-1 GBit/s X-ray receiver fortiming measurements / J. Lauter ; A. Förster ; H. Lüth ... JF - IEEE Transactions on Nuclear Science (T-NS). 43 (1996), H. 3, Part 2 Y1 - 1996 SN - 0018-9499 SP - 1446 EP - 1451 ER - TY - JOUR A1 - Förster, Arnold A1 - Lachenmann, S. G. A1 - Kastalsky, A. T1 - Novel hybrid Nb/InAs/Nb step junctions / S. G. Lachenmann ; A. Kastalsky ; I. Friedrich ; A. Förster ... JF - Czechoslovak journal of physics . 46 (1996), H. S2 Y1 - 1996 SN - 0011-4626 SP - 659 ER - TY - JOUR A1 - Förster, Arnold A1 - Schmidt, T. A1 - Haug, R. J. T1 - Spectroscopy of the single-particle states of a quantum-dot molecule / T. Schmidt ; R. J. Haug ; K. v. Klitzing ; A. Förster ... JF - Physical review letters. 78 (1997), H. 8 Y1 - 1997 SN - 0031-9007 N1 - ISSN der E-Ausg.: 1079-7114 SP - 1544 EP - 1547 ER - TY - JOUR A1 - Förster, Arnold A1 - Schmidt, T. A1 - Haug, R. J. T1 - Observation of the local structure of landau bands in a disordered conductor / T. Schmidt ; R. J. Haug ; Vladimir I. Fal'ko ... A. Förster ... JF - Physical review letters. 78 (1997), H. 8 Y1 - 1997 SN - 0031-9007 N1 - ISSN der E-Ausg.: 1079-7114 SP - 1540 EP - 1543 ER - TY - JOUR A1 - Förster, Arnold A1 - Rosenauer, A. A1 - Remmele, T. T1 - Atomic scale strain measurements by the digital analysis of transmission electron microscopic lattice images / A. Rosenauer ; T. Remmele ; D. Gerthsen ... A. Förster JF - Optik : international journal for light and electron optics. 105 (1997), H. 3 Y1 - 1997 SN - 0030-4026 SP - 99 EP - 107 ER - TY - JOUR A1 - Förster, Arnold A1 - Lachenmann, S. G. A1 - Kastalsky, A. T1 - Properties of Nb/InAs/Nb hybrid step junctions / S. G. Lachenmann ; A. Kastalsky ; I. Friedrich ; A. Förster ... JF - Journal of low temperature physics. 106 (1997), H. 3-4 Y1 - 1997 SN - 0022-2291 N1 - ISSN der E-Ausg.: 1573-7357 SP - 321 EP - 326 ER - TY - JOUR A1 - Ungermanns, C. A1 - Ahe, M. v. d. A1 - Carius, Reinhard A1 - Förster, Arnold T1 - Optimization of III/V binary growth with RHEED in MOMBE / C. Ungermanns ; M. v. d. Ahe ; R. Carius ; A. Förster ... JF - Fresenius' Journal of Analytical Chemistry. 358 (1997), H. 1-2 Y1 - 1997 SN - 0937-0633 N1 - ISSN der E-Ausg.: 1432-1130 SP - 101 EP - 104 ER - TY - JOUR A1 - Kämper, Klaus-Peter A1 - Schmitt, W. A1 - Güntherodt, G. T1 - Effect of adsorbates on the spin-polarized photoemission of itinerant ferromagnets. Schmitt, W.; Kämper, K.-P.; Güntherodt, G. JF - Physical Review B. 36 (1987), H. 7 Y1 - 1987 SN - 1095-3795 SP - 3763 EP - 3768 ER - TY - JOUR A1 - Kämper, Klaus-Peter A1 - Schmitt, W. A1 - Güntherodt, G. T1 - Thickness dependence of the electronic structure of ultrathin, epitaxial Ni(111)/W(110) layers. JF - Physical Review B. 38 (1988), H. 14 Y1 - 1988 SN - 1095-3795 SP - 9451 EP - 9456 ER - TY - JOUR A1 - Kämper, Klaus-Peter A1 - Schmitt, W. A1 - Güntherodt, G. T1 - Temperature and wave-vector dependence of the spin-split band structure of Ni(111) along the Γ-L line JF - Physical Review B. 42 (1990), H. 16 Y1 - 1990 SN - 1095-3795 SP - 10696 EP - 10705 ER - TY - JOUR A1 - Kämper, Klaus-Peter A1 - Abraham, D. L. A1 - Hopster, H. T1 - Spin-polarized electron-energy-loss spectroscopy on epitaxial fcc Co layers on Cu(001) JF - Physical Review B. 45 (1992), H. 24 Y1 - 1992 SN - 1095-3795 SP - 14335 EP - 14346 ER - TY - JOUR A1 - Kämper, Klaus-Peter A1 - Schmitt, W. A1 - Güntherodt, G. A1 - Gambino, R. J. T1 - CrO2—A New Half-Metallic Ferromagnet? Kämper, K.-P.; Schmitt, W.; Güntherodt, G.; Gambino, R. J., Ruf, R. JF - Physical Review Letters. 59 (1987), H. 24 Y1 - 1987 SN - 1079-7114 SP - 2788 EP - 2791 ER - TY - JOUR A1 - Kämper, Klaus-Peter A1 - Pappas, D. P. A1 - Hopster, H. T1 - Reversible transition between perpendicular and in-plane magnetization in ultrathin films. Pappas, D. P.; Kämper, K.-P.; Hopster, H. JF - Physical Review Letters. 64 (1990), H. 26 Y1 - 1990 SN - 1079-7114 SP - 3179 EP - 3182 ER - TY - JOUR A1 - Kämper, Klaus-Peter A1 - Pappas, D. P. A1 - Miller, B. P. A1 - Hopster, H. T1 - Spin-dependent electron attenuation by transmission through thin ferromagnetic films . Pappas, D. P.; Kämper,K.-P.; Miller, B. P.; Hopster, H.; Fowler, D. E.; Brundle, C. R.; Luntz, A. C.; Shen, Z.-X. JF - Physical Review Letters. 66 (1991), H. 4 Y1 - 1991 SN - 1079-7114 SP - 504 EP - 507 ER - TY - JOUR A1 - Förster, Arnold A1 - Janssen, G. A1 - Roer, T. G. van de T1 - Logic Circuits with reduced complexity based on devices with higher functionality / G. Janssen ; T. G. van de Roer ; W. Prost ... A. Förster JF - Proceedings / STW/SAFE 2nd Annual Workshop on Semiconductor Advances for Future Electronics, Safe '99 - ProRISC/IEEE 10th Annual Workshop on Circuits, Systems and Signal Processing, ProRISC 99 : November 24 - 26, 1999, Mierlo, The Netherlands [Elektronische Ressource] Y1 - 1999 N1 - SAFE <2, 1999, Mierlo> ; Workshop on Circuits, Systems and Signal Processing <10, 1999, Mierlo> ; Stichting voor de Technische Wetenschappen SP - 219 PB - Technology Foundation, STW CY - Utrecht ER - TY - JOUR A1 - Förster, Arnold T1 - Resonant tunneling diodes operating as modern quantum transport devices JF - Proceedings of the Tenth International Workshop on the Physics of Semiconductor Devices : (December 14 - 18, 1999) / ed.: Vikram Kumar ... - Vol. 2 Y1 - 2000 SN - 81-7023-998-2 N1 - International Workshop on the Physics of Semiconductor Devices <10, 1999, Delhi> SP - 966 EP - 966 PB - Allied Publ. CY - New Delhi [u.a.] ER - TY - JOUR A1 - Mayer, Claudia T1 - L'Estétique et le pouvoir: Le discours chaotique de l'Allemagne unifiée JF - Canadian review of comparative literature : CRCL = Revue canadienne de littérature comparée : RCLC / Canadian Comparative Literature Association. 24 (1997), H. 2 Y1 - 1997 SN - 0319-051X SP - 297 EP - 317 ER - TY - JOUR A1 - Mayer, Claudia T1 - Between Trans- and Interdisciplinarity. »Germanistik« and the Dialectic of Inclusion and Exclusion of the Other(s) JF - Language and literature today : proceedings of the XIXth triennal congress of the International Federation for Modern Languages and Literatures ; Brasília 22 - 30 August 1993. General ed. Neide de Faria. Y1 - 1993 SN - 85-230-0405-x N1 - Band 2 SP - 958 EP - 966 PB - Univ. CY - Brasilia ER - TY - JOUR A1 - Mayer, Claudia T1 - Between Resistance and Affirmation: Christa Wolf and German Unification JF - Canadian review of comparative literature : CRCL = Revue canadienne de littérature comparée / Canadian Comparative Literature Association. 22 (1995), H. 3-4 Y1 - 1995 SN - 0319-051X SP - 813 EP - 835 ER - TY - JOUR A1 - Pawelke, Siegfried A1 - Butzer, Paul L. T1 - Semi-groups and resolvent operators JF - Archive for Rational Mechanics and Analysis KW - Resolvent Operator KW - Electromagnetism KW - Complex System KW - Neural Network KW - Nonlinear Dynamics Y1 - 1968 U6 - https://doi.org/10.1007/BF00250941 SN - 0003-9527 VL - 30 IS - 2 SP - 127 EP - 147 PB - Springer CY - Berlin ER - TY - JOUR A1 - Pawelke, Siegfried T1 - Weak smoothness conditions for the uniform convergence of Fourier-Jacobi series JF - Functiones et Approximatio. Commentarii Mathematici. 9 (1980) Y1 - 1980 SN - 0208-6573 N1 - Zentralblatt MATH: http://www.emis.de/MATH-item?0471.42018 SP - 9 EP - 13 ER - TY - JOUR A1 - Biselli, Manfred A1 - Schröder, B. A1 - Herfurth, C. A1 - Schmoll, H.-J. T1 - Cocultivation of hematopoietic cells in a fluidized bed reactor / Schröder, B. ; Herfurth, C. ; Biselli, M. ; Schmoll, H.-J. ; Link, H. ; Ebell, W. ; Wandrey, C. JF - Animal cell technology : basic & applied aspects : proceedings of the Eighth Annual Meeting of the Japanese Association for Animal Cell Technology, Iizuka, Fukuoka, Japan, November 6-10, 1995 / edited by K. Funatsu, Y. Shirai, and T. Matsushita Y1 - 1997 SN - 0-7923-4486-3 N1 - Japanese Association for Animal Cell Technology. ; Meeting ; <8 ; 1995 : ; Iizuka-shi, Japan> SP - 137 EP - 141 PB - Kluwer Acad. Press CY - Boston ER - TY - JOUR A1 - Biselli, Manfred A1 - Klyushnichenko, Vadim A1 - Rodenbrock, Anja A1 - Thömmes, Jörg T1 - Analysis of Hybridoma Cell Culture Processes by SDS-Gel Capillary Electrophoresis and matrix-assisted laser desorption ionization–time-of-flight MS / Vadim Klyushnichenko, Anja Rodenbrock, Jörg Thömmes, Maria-Regina Kula, Holger Heine, Manfred Biselli JF - Biotechnology and Applied Biochemistry. 27 (1998), H. 3 Y1 - 1998 SN - 0885-4513 SP - 181 EP - 188 ER - TY - JOUR A1 - Biselli, Manfred A1 - Noll, T. T1 - Dielectric spectroscopy in the cultivation of suspended and immobilized hybridoma cells / Noll, T.; Biselli, M. JF - Journal of Biotechnology. 63 (1998), H. 3 Y1 - 1998 SN - 0168-1656 SP - 187 EP - 198 ER - TY - JOUR A1 - Biselli, Manfred A1 - Hilbert, U. A1 - Noll, T. T1 - Cultivation of Human HCMV Specific Lymphocytes – An Example for Adoptive Immunotherapy / Hilbert, U. ; Biselli, M. ; Noll, T. JF - Animal cell technology : from target to market ; Tylösand, Sweden, June 10 - 14, 2001 / ed. by E. Lindner-Olsson ... Y1 - 2001 SN - 1-4020-0264-5 N1 - Proceedings of the ... ESACT meeting ; 17 SP - 558 EP - 561 PB - Kluwer CY - Dordrecht ER - TY - JOUR A1 - Scherer, Ulrich W. A1 - Zimmermann, H. P. A1 - Gober, M. K. A1 - Kratz, J. V. T1 - Chemical Properties of Element 105 in Aqueous Solution: Back Extraction from Triisooctyl Amine into 0.5M HCl / H.P. Zimmermann, M.K. Gober, J.V. Kratz, M. Schädel, E. Schimpf, K.E. Gregorich, A. Türler, K.R. Czerwinski, N.J. Hannink, B. Kadkhodayan, D.M. JF - Radiochimica Acta. 60 (1993) Y1 - 1993 SN - 0033-8230 SP - 11 ER - TY - JOUR A1 - Scherer, Ulrich W. A1 - Tomasberger, T. A1 - Veltkamp, T. C. A1 - Booij, A. S. T1 - Radiocesium Removal from High Level Liquid Waste and Immobilisation in Sodium SilicoTitanate for Geological Disposal / T. Tomasberger, T.C. Veltkamp, A.S. Booij, U.W. Scherer JF - Radiochimica Acta. 89 (2001), H. 3 Y1 - 2001 SN - 0033-8230 SP - 145 EP - 150 ER - TY - JOUR A1 - Scherer, Ulrich W. A1 - Kratz, J. V. A1 - Gober, M. K. A1 - Zimmermann, H. P. T1 - New nuclide 263 105 / J.V. Kratz, M.K. Gober, H.P. Zimmermann, M. Schädel, W. Brüchle, E. Schimpf, K.E. Gregorich, A. Türler, N.J. Hannink, K.R. Czerwinski, B. Kadkhodayan, D.M. Lee, M.J. Nurmia, D.C. Hoffman, H. Gäggeler, D. Jost, U.W. Scherer, A. Weber JF - Physical Review C . 45 (1992) Y1 - 1992 SP - 1064 EP - 1069 ER - TY - JOUR A1 - Scherer, Ulrich W. A1 - Baltensperger, Urs A1 - Ammann, Markus A1 - Bochert, Ulrich K. T1 - Use of 13N for Studies of the Selective Reduction of NO by NH3 over Vanadia/Titania Catalyst at Very Low Reactant Concentrations / Urs Baltensperger, Markus Ammann, Ulrich K. Bochert, Bernd Eichler, Heinz W. Gäggeler, Dieter T. Jost, Joseph A. Kovacs, An JF - Journal of Physical Chemistry. 97 (1993) Y1 - 1993 SN - 0022-3654 SP - 12325 EP - 12330 ER - TY - JOUR A1 - Scherer, Ulrich W. A1 - Hör, G. T1 - Artifacts and Pitfalls in FDG-PET Whole-Body Scans / U.W. Scherer, G. Hör JF - Radionuclides for Mammary Gland - Current Status and Future Aspects / G. S. Limouris [Hrsg.] Y1 - 1997 SN - 960-85227-6-5 SP - 37 EP - 42 PB - Mediterra Publishers CY - Athen ER - TY - JOUR A1 - Scherer, Ulrich W. A1 - Hör, G. A1 - Kranert, W. T. A1 - Maul, F. D. T1 - Gated Metabolic Positron Emission Tomography (GAPET) of Myocardium: 18F-FDG/PET to optimize Recognition of Myocardial Hibernation / G. Hör, W.T. Kranert, F.D. Maul, O. Schröder, A. Karimian-Tatriz, O. Geb, R.P. Baum, U.W. Scherer JF - Nuclear Medicine Communications. 19 (1998) Y1 - 1998 SN - 0143-3636 SP - 535 EP - 545 ER -