TY - JOUR A1 - Turek, Monik A1 - Heiden, Wolfgang A1 - Guo, Sharon A1 - Riesen, Alfred A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs JF - Physica Status Solidi (A) N2 - In environmental analysis, cyanide and heavy metals play an important role, because these substances are highly toxic for biological systems. They can lead to chronic and acute diseases. Due to the chemical properties of cyanide it is frequently used for industrial processes such as extraction of silver and gold. Heavy metals can be found as trace elements in nature and are often applied in industries e.g., galvanization processes. Up to now, cyanide and heavy metals can be detected by several sensors separately and their detection is often limited to laboratory investigations. In this publication, with regard to an in situ analysis, a new miniaturized silicon-based sensor system for the simultaneous detection of cyanide and heavy metals in aqueous solutions is presented that is based on chalcogenide glass-based micro ion-selective electrodes (µISEs). The µISEs are incorporated into a specially designed measuring system for the simultaneous detection of heavy metals and cyanide in solutions and validated by simultaneous measurements of Cu2+- and CN−-ions, Cd2+- and CN−- ions and Pb2+- and CN−-ions. The particular sensor system has shown good sensor properties in the µ-molar ion-concentration range. For simultaneous measurements in complex heavy metal and cyanide solutions an intelligent software using fuzzy logic is discussed. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983303 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 817 EP - 823 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Jansen, S. V. A1 - Behbahani, Mehdi A1 - Laumen, M. A1 - Kaufmann, T. A1 - Hormes, M. A1 - Behr, Marek A1 - Schmitz-Rode, T. A1 - Steinseifer, U. T1 - Investigation of Steady Flow Through a Realistic Model of the Thoracic Human Aorta Using 3D Stereo PIV and CFD-Simulation JF - ASAIO Journal Y1 - 2010 U6 - https://doi.org/10.1097/01.mat.0000369377.65122.a3 N1 - American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 VL - 56 IS - 2 SP - 98 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Mai, A. A1 - Tran, L. A1 - Vonderstein, K. A1 - Keschenau, P. A1 - Linde, T. A1 - Steinseifer, U. A1 - Behr, Marek A1 - Mottaghy, K. T1 - The influence of high shear on thrombosis and hemolysis in artificial organs JF - The International Journal of Artificial Organs Y1 - 2010 SN - 0391-3988 VL - 33 IS - 7 SP - 426 EP - 426 PB - Sage CY - Thousand Oaks ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Nam, J. A1 - Waluga, C. A1 - Behr, Marek A1 - Pasquali, M. A1 - Mottaghy, K. T1 - Modeling and Numerical Analysis of Platelet Activation, Adhesion and Aggregation in Artificial Organs Y1 - 2010 U6 - https://doi.org/10.1097/01.mat.0000369377.65122.a3 N1 - Posterpresentation American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 VL - 56 IS - 2 SP - 85 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Beckers, Leah A1 - Schaub, A. A1 - Zander, W. A1 - Schubert, J. A1 - Mesters, S. A1 - Kordos, P. A1 - Lüth, H. T1 - A novel silicon-based pH sensor prepared by pulsed laser deposition technique JF - Proceedings of Eurosensors X, the 10th European Conference on Solid-State Transducers, September 8-11, 1996, Leuven, Belgium / [KU Leuven]. Puers, Robert. Vol. 3. Y1 - 1996 SN - 90-803282-1-9 N1 - Eurosensors ; (10, 1996, Louvain) Eurosensors, the European Conference on Solid-State Transducers ; (10 : ; 1996.09.08-11 : ; Leuven) SP - 781 EP - 784 PB - Catholic University Leuven CY - Heverlee, Belgium ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Mai, A. A1 - Waluga, C. A1 - Bergmann, B. A1 - Tran, L. A1 - Vonderstein, K. A1 - Behr, Marek A1 - Mottaghy, K. T1 - Numerical Modeling of Flow-Related Thrombus Formation under Physiological and Non-Physiological Flow Conditions JF - Acta Physiologica Y1 - 2010 SN - 1748-1716 N1 - Joint Congress of the Scandinavian and German Physiological Societies, Copenhagen, Denmark, March 27-30, 2010 VL - 198 IS - Supplement 677 SP - 185 ER - TY - JOUR A1 - Siqueira, José R. Jr. A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Associating biosensing properties with the morphological structure of multilayers containing carbon nanotubes on field-effect devices JF - Physica Status Solidi (A) N2 - The control of molecular architecture provided by the layer-by-layer (LbL) technique has led to enhanced biosensors, in which advantageous features of distinct materials can be combined. Full optimization of biosensing performance, however, is only reached if the film morphology is suitable for the principle of detection of a specific biosensor. In this paper, we report a detailed morphology analysis of LbL films made with alternating layers of single-walled carbon nanotubes (SWNTs) and polyamidoamine (PAMAM) dendrimers, which were then covered with a layer of penicillinase (PEN). An optimized performance to detect penicillin G was obtained with 6-bilayer SWNT/PAMAM LbL films deposited on p-Si-SiO2-Ta2O5 chips, used in biosensors based on a capacitive electrolyte-insulator-semiconductor (EIS) and a light-addressable potentiometric sensor (LAPS) structure, respectively. Field-emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) images indicated that the LbL films were porous, with a large surface area due to interconnection of SWNT into PAMAM layers. This morphology was instrumental for the adsorption of a larger quantity of PEN, with the resulting LbL film being highly stable. The experiments to detect penicillin were performed with constant-capacitance (ConCap) and constant-current (CC) measurements for EIS and LAPS sensors, respectively, which revealed an enhanced detection signal and sensitivity of ca. 100 mV/decade for the field-effect sensors modified with the PAMAM/SWNT LbL film. It is concluded that controlling film morphology is essential for an enhanced performance of biosensors, not only in terms of sensitivity but also stability and response time. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983301 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 781 EP - 786 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Reisert, Steffen A1 - Schubert, J. A1 - Zander, W. A1 - Begoyan, Vardges K. A1 - Buniatyan, V. V. A1 - Schöning, Michael Josef T1 - Chemical sensors based on a high-k perovskite oxide of barium strontium titanate JF - Procedia Engineering N2 - High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors for liquids. In this work, BST films have been applied as a sensitive transducer material for a label-free detection of adsorbed charged macromolecules (positively charged polyelectrolytes) and concentration of hydrogen peroxide vapor as well as protection insulator layer for a contactless electrolyte-conductivity sensor. The experimental results of characterization of individual sensors are presented. Special emphasis is devoted towards the development of a capacitively-coupled contactless electrolyte-conductivity sensor. KW - barium strontium titanate KW - high-k material KW - contactless conductivity sensor KW - multi-functional material KW - hydrogen peroxide Y1 - 2014 U6 - https://doi.org/10.1016/j.proeng.2014.11.258 SN - 1877-7058 N1 - EUROSENSORS 2014 ; European Conference on Solid-State Transducers <28, 2014> VL - 87 SP - 28 EP - 31 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Tran, L. A1 - Waluga, C. A1 - Behr, Marek A1 - Oedekoven, B. A1 - Mottaghy, K. T1 - Model-based Numerical Analysis of Platelet Adhesion, Thrombus Growth and Aggregation for Assist Devices JF - The International Journal of Artificial Organs. 32 (2009), H. 7 Y1 - 2009 SN - 0391-3988 N1 - Abstracts - Oral Presentations: XXXVI Annual ESAO Congress, 2-5 September 2009, Compiègne - France; European Society of Artificial Organs (ESAO), Compiegne, France, September 2-5, 2009 SP - 398 EP - 398 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schaub, A. A1 - Zundel, A. A1 - Beckers, Leah A1 - Schubert, J. A1 - Zander, W. A1 - Kordos, P. A1 - Lüth, H. T1 - Pulsed laser deposition as a novel thin film preparation method for silicon-based field effect sensors JF - Proceedings of the 25th European Solid State Device Research Conference : the Netherlands Congress Centre, The Hague, the Netherlands, 25th - 27th September 1995 / ESSDERC '95. Ed. by H. C. de Graaff Y1 - 1995 SN - 2-86332-182-X N1 - ESSDERC ; (25, 1995, 's-Gravenhage) ; European Solid State Device Research Conference (ESSDERC) ; (25 : ; 1995.09.25-27 : ; Den Haag) SP - 601 EP - 604 PB - Ed. Frontières CY - Gif-sur-Yvette ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, Marek A1 - Arora, D. A1 - Coronado, O. A1 - Pasquali, M. T1 - CFD Analysis of MicroMed Debakey Pump and Hemolysis Prediction / Behbahani, M. ; Behr, M. ; Arora, D. ; Coronado, O. ; Pasquali, M. JF - Artificial Organs. 30 (2006), H. 11 Y1 - 2006 SN - 1525-1594 N1 - Abstracts 14th Congress of the International Society for Rotary Blood Pumps, Leuven, Belgium, August 31–September 2, 2006 ; S7-4 SP - A45 EP - A46 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, Marek A1 - Hormes, M. A1 - Steinseifer, U. A1 - Arora, D. A1 - Coronado, O. A1 - Pasquali, M. T1 - A Review of Computational Fluid Dynamics Analysis of Blood Pumps JF - European Journal of Applied Mathematics. 20 (2009), H. 4 Y1 - 2009 SP - 363 EP - 397 PB - Cambridge Univ. Press CY - Cambridge ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Tran, L. A1 - Jockenhövel, S. A1 - Behr, Marek A1 - Mottaghy, K. T1 - Numerical prediction of thrombocyte reactions for application to a vascular flow model JF - British Journal of Surgery Y1 - 2011 SN - 1365-2168 N1 - 46th Congress of the European Society for Surgical Research, Aachen, Germany, 25-28 May 2011 ; ESSR Abstracts 2011 ; Oral Sessions OP10-5 VL - 98 IS - S5 SP - S17 PB - Oxford University Press CY - Oxford ER - TY - JOUR A1 - Ribitsch, Doris A1 - Heumann, Sonja A1 - Karl, Wolfgang A1 - Gerlach, Jochen A1 - Leber, R. A1 - Birner-Gruenberger, R. A1 - Gruber, K. A1 - Eiteljoerg, I. A1 - Remler, Peter A1 - Siegert, Petra A1 - Lange, J. A1 - Maurer, Karl-Heinz A1 - Berg, G. A1 - Guebitz, G. M. A1 - Schwab, H. T1 - Extracellular serine proteases from Stenotrophomonas maltophilia: Screening, isolation and heterologous expression in E. coli JF - Journal of biotechnology N2 - A large strain collection comprising antagonistic bacteria was screened for novel detergent proteases. Several strains displayed protease activity on agar plates containing skim milk but were inactive in liquid media. Encapsulation of cells in alginate beads induced protease production. Stenotrophomonas maltophilia emerged as best performer under washing conditions. For identification of wash-active proteases, four extracellular serine proteases called StmPr1, StmPr2, StmPr3 and StmPr4 were cloned. StmPr2 and StmPr4 were sufficiently overexpressed in E. coli. Expression of StmPr1 and StmPr3 resulted in unprocessed, insoluble protein. Truncation of most of the C-terminal domain which has been identified by enzyme modeling succeeded in expression of soluble, active StmPr1 but failed in case of StmPr3. From laundry application tests StmPr2 turned out to be a highly wash-active protease at 45 °C. Specific activity of StmPr2 determined with suc-l-Ala-l-Ala-l-Pro-l-Phe-p-nitroanilide as the substrate was 17 ± 2 U/mg. In addition we determined the kinetic parameters and cleavage preferences of protease StmPr2. KW - Alginate beads KW - Stenotrophomonas maltophilia KW - Detergent protease Y1 - 2012 U6 - https://doi.org/10.1016/j.jbiotec.2011.09.025 SN - 1873-4863 (E-Journal); 0168-1656 (Print) VL - 157 IS - 1 SP - 140 EP - 147 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Grundmann, Jan Thimo A1 - Bauer, Waldemar A1 - Biele, Jens A1 - Boden, Ralf A1 - Ceriotti, Matteo A1 - Cordero, Federico A1 - Dachwald, Bernd A1 - Dumont, Etienne A1 - Grimm, Christian D. A1 - Hercik, David T1 - Capabilities of Gossamer-1 derived small spacecraft solar sails carrying Mascot-derived nanolanders for in-situ surveying of NEAs JF - Acta Astronautica Y1 - 2019 U6 - https://doi.org/10.1016/j.actaastro.2018.03.019 SN - 0094-5765 VL - 156 IS - 3 SP - 330 EP - 362 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Nam, J. A1 - Arora, D. A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Benkowski, R. A1 - Behr, Marek A1 - Pasquali, M. T1 - New computational method in hemolysis analysis for artificial heart pump Y1 - 2010 N1 - Posterpresentation ; American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 ER - TY - CHAP A1 - Bäcker, Matthias A1 - Koch, Claudia A1 - Geiger, Fania A1 - Eber, Fabian A1 - Gliemann, Hartmut A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - A New Class of Biosensors Based on Tobacco Mosaic Virus and Coat Proteins as Enzyme Nanocarrier T2 - Procedia Engineering Y1 - 2016 U6 - https://doi.org/10.1016/j.proeng.2016.11.228 SN - 1877-7058 N1 - Proceedings of the 30th anniversary Eurosensors Conference – Eurosensors 2016, 4-7. Sepember 2016, Budapest, Hungary VL - Vol. 168 SP - 618 EP - 621 ER - TY - JOUR A1 - Ullrich, Sebastian A1 - Grottke, Oliver A1 - Rossaint, Rolf A1 - Staat, Manfred A1 - Deserno, Thomas M. A1 - Kuhlen, Torsten T1 - Virtual Needle Simulation with Haptics for Regional Anaesthesia Y1 - 2010 N1 - IEEE Virtual Reality 2010, Workshop on Medical Virtual Environments, Waltham, MA, USA, March 21, 2010 ER - TY - JOUR A1 - Kämper, Klaus-Peter A1 - Berg, U. A1 - Begemann, M. A1 - Hagemann, B. T1 - Series production and testing of a micro motor. Serienfertigung und Prüfung eines Mikromotors JF - Actuator 98 : 6th International Conference on New Actuators ; 17 - 19 June, 1998, Bremen, Germany ; conference proceedings / ed.: Hubert Borgmann ... Y1 - 1998 SN - 3-933339-00-6 N1 - Konferenz-Einzelbericht: ACTUATOR, Internat. Conf. on New Actuators SP - 552 EP - 555 PB - Messe Bremen CY - Bremen ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Waluga, C. A1 - Arlt, S. A1 - Behr, Marek A1 - Mottaghy, K. T1 - Computational Analysis of Platelet Aggregation in a Taylor-Couette System JF - The International Journal of Artificial Organs. 31 (2008), H. 7 Y1 - 2008 SN - 0391-3988 N1 - Posterpresentation ; European Society of Artificial Organs (ESAO), Geneva, Switzerland SP - 643 ER - TY - JOUR A1 - Ribitsch, Doris A1 - Karl, Wolfgang A1 - Birner-Gruenberger, R. A1 - Gruber, K. A1 - Eiteljoerg, I. A1 - Remler, Peter A1 - Wieland, S. A1 - Siegert, Petra A1 - Maurer, Karl-Heinz A1 - Schwab, H. T1 - C-terminal truncation of a metagenome-derived detergent protease for effective expression in E. coli JF - Journal of biotechnology N2 - Recently, a new alkaline protease named HP70 showing highest homology to extracellular serine proteases of Stenotrophomonas maltophilia and Xanthomonas campestris was found in the course of a metagenome screening for detergent proteases (Niehaus et al., submitted for publication). Attempts to efficiently express the enzyme in common expression hosts had failed. This study reports on the realization of overexpression in Escherichia coli after structural modification of HP70. Modelling of HP70 resulted in a two-domain structure, comprising the catalytic domain and a C-terminal domain which includes about 100 amino acids. On the basis of the modelled structure the enzyme was truncated by deletion of most of the C-terminal domain yielding HP70-C477. This structural modification allowed effective expression of active enzyme using E. coli BL21-Gold as the host. Specific activity of HP70-C477 determined with suc-l-Ala-l-Ala-l-Pro-l-Phe-p-nitroanilide as the substrate was 30 ± 5 U/mg compared to 8 ± 1 U/mg of the native enzyme. HP70-C477 was most active at 40 °C and pH 7–11; these conditions are prerequisite for a potential application as detergent enzyme. Determination of kinetic parameters at 40 °C and pH = 9.5 resulted in KM = 0.23 ± 0.01 mM and kcat = 167.5 ± 3.6 s⁻¹. MS-analysis of peptide fragments obtained from incubation of HP70 and HP70-C477 with insulin B indicated that the C-terminal domain influences the cleavage preferences of the enzyme. Washing experiments confirmed the high potential of HP70-C477 as detergent protease. Y1 - 2010 U6 - https://doi.org/10.1016/j.jbiotec.2010.09.947 SN - 1873-4863 (E-Journal); 0168-1656 (Print) VL - 150 IS - 3 SP - 408 EP - 416 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ribitsch, Doris A1 - Heumann, Sonja A1 - Trotscha, E. A1 - Herrero Acero, E. A1 - Greimel, K. A1 - Leber, R. A1 - Birner-Gruenberger, R. A1 - Deller, S. A1 - Eiteljoerg, I. A1 - Remler, Peter A1 - Weber, Th. A1 - Siegert, Petra A1 - Maurer, Karl-Heinz A1 - Donelli, I. A1 - Freddi, G. A1 - Schwab, H. A1 - Guebitz, G. M. T1 - Hydrolysis of polyethyleneterephthalate by p-nitrobenzylesterase from Bacillus subtilis JF - Biotechnology progress Y1 - 2011 SN - 1520-6033 (E-Journal); 8756-7938 (Print) VL - Vol. 27 IS - Iss. 4 SP - 951 EP - 960 PB - Wiley CY - Hoboken ER - TY - CHAP A1 - Seefeldt, Patric A1 - Bauer, Waldemar A1 - Dachwald, Bernd A1 - Grundmann, Jan Thimo A1 - Straubel, Marco A1 - Sznajder, Maciej A1 - Tóth, Norbert A1 - Zander, Martin E. T1 - Large lightweight deployable structures for planetary defence: solar sail propulsion, solar concentrator payloads, large-scale photovoltaic power T2 - 4th IAA Planetary Defense Conference - PDC 2015, 13-17 April 2015, Frascati, Roma, Italy Y1 - 2015 N1 - IAA-PDC-15-P-20 ER - TY - JOUR A1 - Probst, M. A1 - Behbahani, Mehdi A1 - Borrmann, E. A1 - Elgeti, S. A1 - Nicolai, M. A1 - Behr, Marek T1 - Hemodynamic Modeling for Numerical Analysis and Design of Medical Devices Y1 - 2010 N1 - Posterpresentation ; NIC Symposium 2010 ; 24 - 25 February 2010 Jülich, Germany ER - TY - JOUR A1 - Esch, Thomas A1 - Salber, Wolfgang A1 - Wolters, Peter A1 - Geiger, José A1 - Dilthey, Jochen T1 - Synergies of variable valve actuation and direct injection JF - Direct injection SI engine technology 2002 : [SAE 2002 world congress, Detroit, Michigan, USA, March 4 - 7, 2002]. Y1 - 2002 SN - 0-7680-0961-8 N1 - Konferenz-Einzelbericht SP - 45 EP - 53 PB - Society of Automotive Engineers CY - Warrendale, Pa ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Mai, A. A1 - Bergmann, B. A1 - Waluga, C. A1 - Behr, Marek A1 - Tran, L. A1 - Vonderstein, K. A1 - Mottaghy, K. T1 - Modeling and Numerical Simulation of Blood Damage Y1 - 2010 N1 - Posterpresentation ; Umbrella Symposium "Modelling and Simulation in Medicine, Engineering and Sciences", Forschungszentrum Jülich, January 18-20, 2010 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Mai, A. A1 - Behr, Marek A1 - Tran, L. A1 - Vonderstein, K. A1 - Mottaghy, K. T1 - Numerical Prediction of Blood Damage in Biomedical Devices Y1 - 2010 N1 - Posterpresentation ; Biomedica Congress, Aachen, March 17-18, 2010 ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Waluga, C. A1 - Stock, S. A1 - Mai, A. A1 - Bergmann, B. A1 - Behr, Marek A1 - Tran, L. A1 - Vonderstein, K. A1 - Scheidt, H. A1 - Oedekoven, B. A1 - Mottaghy, K. T1 - Modelling and Numerical Analysis of Platelet Reactions and Surface Thrombus Growth Y1 - 2009 N1 - Posterpresentation ; European Society of Biomaterials (ESB), Lausanne, Switzerland, September 7-10, 2009 ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Maki, Rafael M. A1 - Paulovich, Fernando V. A1 - Werner, Frederik A1 - Poghossian, Arshak A1 - Oliveira, Maria C. F. de A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Use of information visualization methods eliminating cross talk in multiple sensing units investigated for a light-addressable potentiometric sensor JF - Analytical Chemistry N2 - The integration of nanostructured films containing biomolecules and silicon-based technologies is a promising direction for reaching miniaturized biosensors that exhibit high sensitivity and selectivity. A challenge, however, is to avoid cross talk among sensing units in an array with multiple sensors located on a small area. In this letter, we describe an array of 16 sensing units of a light-addressable potentiometric sensor (LAPS), which was made with layer-by-layer (LbL) films of a poly(amidomine) dendrimer (PAMAM) and single-walled carbon nanotubes (SWNTs), coated with a layer of the enzyme penicillinase. A visual inspection of the data from constant-current measurements with liquid samples containing distinct concentrations of penicillin, glucose, or a buffer indicated a possible cross talk between units that contained penicillinase and those that did not. With the use of multidimensional data projection techniques, normally employed in information visualization methods, we managed to distinguish the results from the modified LAPS, even in cases where the units were adjacent to each other. Furthermore, the plots generated with the interactive document map (IDMAP) projection technique enabled the distinction of the different concentrations of penicillin, from 5 mmol L−1 down to 0.5 mmol L−1. Data visualization also confirmed the enhanced performance of the sensing units containing carbon nanotubes, consistent with the analysis of results for LAPS sensors. The use of visual analytics, as with projection methods, may be essential to handle a large amount of data generated in multiple sensor arrays to achieve high performance in miniaturized systems Y1 - 2010 U6 - https://doi.org/10.1021/ac9024076 SN - 0003-2700 VL - 82 IS - 1 SP - 61 EP - 65 PB - ACS Publications CY - Washington ER - TY - JOUR A1 - Grottke, O. A1 - Braunschweig, T. A1 - Philippen, B. A1 - Gatzweiler, Karl-Heinz A1 - Gronloh, N. A1 - Staat, Manfred A1 - Rossaint, R. A1 - Tolba, R. T1 - A new model for blunt liver injuries in the swine JF - European Surgical Research N2 - Background: To elaborate the impact of new haemostatic agents we developed an instrument for the pressure-controlled induction of blunt liver injuries in a porcine animal model. Materials and Methods: A dilutional coagulopathy of 80% of animal blood volume was induced in 9 anaesthetized pigs. Animals were randomly assigned to be injured with a force of 112 Newton (N) (n = 1), 224 ± 19 N (n = 4) or 355 ± 35 N (n = 4). The impact of injury was measured by blood loss, survival time and coagulation parameters. Liver histology was obtained to evaluate the degree of liver injury. Results: The profound haemodilution resulted in a significant alteration of all coagulation parameters. After inflicting the injury with 355 ± 35 N, both the survival time (30 ± 9 min; p = 0.006) and blood loss (68 ± 16 ml min–1, p = 0.002) were significantly different as compared to injuries with 224 ± 19 N (survival time: 76 ± 20 min, blood loss: 23 ± 4 ml min–1). In contrast, an injury with 112 N led to an insignificant blood loss of only 239 ml. Conclusion: We developed a pressure-controlled clamp that allows for the induction of blunt liver traumas with highly reproducible injuries with a positive correlation with blood loss and survival. Y1 - 2010 U6 - https://doi.org/10.1159/000265053 SN - 1421-9921 VL - 44 IS - 2 SP - 65 EP - 73 PB - Karger CY - Basel ER - TY - CHAP A1 - Lettini, Antonio A1 - Havermann, Marc A1 - Guidetti, Marco A1 - Fornaciari, Andrea T1 - Improved functionalities and energy saving potential on mobile machines combining electronics with flow sharing valve and variable displacement pump T2 - 7th International Fluid Power Conference - Vol. 3 - Aachen Efficiency through Fluid Power Workshop Proceedings Y1 - 2010 SN - 978-3-940565-92-1 N1 - IFK, 7, Internationales Fluidtechnisches Kolloquium, 7., Aachen, DE, 2010-03-22 - 2010-03-24 SP - 103 EP - 114 PB - Apprimus Verlag CY - Aachen ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Nicolai, M. A1 - Probst, M. A1 - Behr, Marek T1 - Simulation of Blood Flow in a Ventricular Assist Device JF - inSIDE. 5 (2007), H. 1 Y1 - 2007 SP - 28 EP - 31 ER - TY - BOOK A1 - Ley, Wilfried A1 - Wittmann, Klaus A1 - Hallmann, Willi T1 - Handbook of space technology Y1 - 2009 SN - 978-0-470-69739-9 PB - Wiley CY - Chichester ER -