TY - CHAP A1 - Kern, Alexander A1 - Dikta, Gerhard T1 - Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies N2 - In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not. KW - Blitzschutz KW - lightning flash Y1 - 2009 ER - TY - GEN A1 - Kaster, Jan Mathis T1 - Untersuchungen zur Specklereduktion bei der Infrarot-Laser gestützten Ferndetektion von TNT-Oberflächenkontaminationen T1 - Studies on specklereduction in the infrared laser based remote detection of TNT surface contaminations N2 - Das Ziel der vorliegenden Arbeit ist die Specklereduktion bei der Infrarotlaser-gestützten abbildenden Ferndetektion von TNT-Oberflächenkontaminationen. Für die Detektion wird die Probenoberfläche mit einem abstimmbaren Quantenkaskadenlaser bei verschiedenen Wellenzahlen im Spektralbereich von 1340cm-1 bis 1380cm-1 bestrahlt, während eine Infrarot-Kamera Bilder der bestrahlten Fläche aufzeichnet. Diese Bilder werden dann so verarbeitet, dass im Ausgabebild die chemisch spezifische TNT-Absorption durch eine Änderung der Helligkeit örtlich aufgelöst erkennbar werden. Da kohärente Strahlung, welche beispielsweise an optisch rauen Oberflächen reflektiert wird, aufgrund der stochastischen Verteilung der Oberflächenrautiefe mit der einfallenden Strahlung lateral unterschiedlich interferiert, entsteht ein „Rauschen“ in der aufgezeichneten Strahlungsleistungsverteilung, das sog. Speckle-Phänomen. Die Empfindlichkeit der oben skizzierten Lasergestützten Messtechnik wird im Wesentlichen durch diesen Effekt limitiert. Um die durch Laserspeckles verursachten Rauschanteile zu reduzieren, gibt es verschiedene Möglichkeiten. Durch Reduktion von zeitlicher und räumlicher Kohärenz der Strahlung wird deren Interferenzfähigkeit reduziert und durch Variieren des Specklemusters während einer Bildaufzeichnung führen Mittelungen unkorrelierter Rauschanteile zu einer Specklekontrastreduktion. Letztere Möglichkeit resultiert daraus, dass Laserspeckles statistisch durch die Familie der Gammaverteilungen beschrieben werden können. Demnach verbessert sich das Signal-zu-Rausch-Verhältnis mit der Anzahl gemittelter, unkorrelierter Rauschmuster proportional zur Wurzel dieser Anzahl. Ein im MIR-Spektralbereich umsetzbarer Ansatz, der all diese Möglichkeiten berücksichtigt, wurde bereits 1971 von Lowenthal und Joyeaux vorgeschlagen und im Rahmen der vorliegenden Arbeit für den infraroten Spektralbereich adaptiert. Dazu wird die Strahlung mit zwei CVD-Diamant-Wafern moduliert; ein Wafer ist dabei stationär und der andere rotiert mit ca. 70Hz. In der vorliegenden Arbeit konnte mit diesem Ansatz eine Verbesserung des Signal-zu-Rausch-Verhältnisses in der betrachteten Strahlungsleistungs¬verteilung von ursprünglich 3 auf etwa 45 erzielt werden. So konnten erstmals TNT-Kontaminationen von bis zu 10µg/cm² in einem Abstand von 5m abbildend nachgewiesen werden. Dies entspricht der Kontamination durch einen mit TNT leicht verunreinigten Fingerabdruck. KW - Speckle KW - Infrarot-Reflexions-Absorptions-Spektroskopie KW - MIR-Spektroskopie KW - Infrarotmesstechnik KW - Quantenkaskadenlaser KW - Fernerkundung KW - Trinitrotol Y1 - 2009 ER - TY - JOUR A1 - Wettingfeld, Jürgen A1 - Kern, Alexander A1 - Krämer, Heinz-Josef A1 - Thormählen, Reyno T1 - International anerkannte Blitzschutznormen : Ausgewogener und sicherer Schutz N2 - Die Einleitung zur Norm DIN EN 62305-3 beschreibt klar und ein - deutig: Der vorliegende Teil der IEC 62305 behandelt den Schutz von baulichen Anlagen gegen materielle Schäden und den Schutz von Personen gegen Verletzungen durch Berührungs- und Schrittspannungen. Als das wesentlichste und effektivste Mittel zum Schutz von baulichen Anlagen gegen materielle Schäden gilt das Blitz - schutzsystem (LPS). KW - Blitzschutz KW - lightning protection Y1 - 2009 PB - Fachhochschule Aachen CY - Aachen ER - TY - CHAP A1 - Kern, Alexander A1 - Beierl, Ottmar A1 - Zischank, Wolfgang T1 - Calculation of the separation distance according to IEC 62305-3: 2006-10 - Remarks for the application and simplified methods N2 - [Paper of the X International Symposium on Lightning Protection 9th - 13th November, 2009 - Curitiba, Brazil. 6 pages] The international standard IEC 62305-3, published in 2006, requires as an integral part of the lightning protection system (LPS) the consideration of a separation distance between the conductors of the LPS and metal and electrical installations inside the structure to be protected. IEC 62305-3 gives two different methods for this calculation: a standard, simplified approach and a more detailed approach, which differ especially regarding the treatment of the current sharing effect on the LPS conductors. Hence, different results for the separation distance are possible, leading to some discrepancies in the use of the standard. The standard approach defined in the main part (Clause 6.3) and in Annex C of the standard in some cases may lead to a severe oversizing of the required separation distance. The detailed approach described in Annex E naturally gives more correct results. However, a calculation of the current sharing amongst all parts of the air-termination and downconductor network is necessary, in many cases requiring the use of network analysis programs. In this paper simplified methods for the assessment of the current sharing are presented, which are easy to use as well as sufficiently adequate. KW - Blitzschutz KW - Lightning protection Y1 - 2009 N1 - Paper in: [10. International Symposium on Lightning Protection 9. 13. November 2009, Curitiba, Brasilien. 6 Seiten] ER - TY - CHAP A1 - Behrens, Jörg A1 - Frentzel, Ralf A1 - Kern, Alexander T1 - Simulation der transienten Spannungsverläufe im Eigenbedarfsnetz eines Großkraftwerks bei einem kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung T1 - Simulation of transient voltage curve of a house-load operation net-work of large power plant by a lightning strike in a high-voltage over-head line closed to the power plant N2 - 8. VDE/ABB-Blitzschutztagung, 29. - 30. Oktober 2009 in Neu-Ulm. Blitzschutztagung <8, 2009, Neu-Ulm> Berlin : VDE Verl. 2009 Großkraftwerke können durch Blitzentladungen mit potentiellen Auswirkungen auf deren Verfügbarkeit und Sicherheit gefährdet werden. Ein sehr spezielles Szenario, welches aus aktuellem Anlass zu untersuchen war, betrifft den kraftwerksnahen Blitzeinschlag in die Hochspannungs-Freileitung am Netzanschluss der Anlage. Wird nun noch ein sogenannter Schirmfehler unterstellt, d.h. der direkte Blitzeinschlag erfolgt in ein Leiterseil des Hoch- bzw. Höchstspannungsnetzes und nicht in das darüber gespannte Erdseil, so bedeutet dies eine extreme elektromagnetische Einwirkung. Der vorliegende Beitrag befasst sich mit der Simulation eines solchen Blitzeinschlages und dessen Auswirkungen auf den Netzanschluss und die Komponenten der elektrischen Eigenbedarfsanlagen eines Kraftwerks auf den unterlagerten Spannungsebenen. Die dabei gewonnenen Erkenntnisse lassen sich ohne Einschränkungen auf Industrieanlagen mit Mittelspannungs-Netzanschluss und ohne eigener Stromversorgung übertragen. N2 - Lightning discharge can endanger large power plants with potential influence on their availability and reliability. A very special scenario, which was currently to analyse, is the lightning strike close to the high-voltage overhead line at the grid of the power plant. Supposing a failure of shielding and that the lightning strike goes directly into the line then the elec-tromagnetic effect is extremely high. The following article gives attention to the simulation of lightning strike and their effects to the connection with the grid and the components of the house-load operation of a large power plant especially to the lower voltage level sections. These results are transferable to industrial plants which have no own power supply. KW - Blitzschutz KW - Blitzeinschlag KW - lightning strike Y1 - 2009 SN - 978-3-8007-3197-8 ER - TY - JOUR A1 - Kern, Alexander A1 - Klöters, Georg A1 - Pferdmenges, Jörg T1 - Blitzschutzoptimierung in der LST an nicht-elektrifizierten Strecken JF - Signal und Draht. 101 (2009), H. 4 Y1 - 2009 SN - 0037-4997 SP - 17 EP - 21 PB - DVV Media Group CY - Hamburg ER - TY - JOUR A1 - Kern, Alexander A1 - Beierl, O. A1 - Zischank, W. T1 - DIN EN 62 305-3 - Berechnung des Trennungsabstands (Anmerkungen zur Anwendung der Berechnungsverfahren und vereinfachte Verfahren zur Abschätzung der Stromaufteilung) / Kern, A. ; Beierl, O. ; Zischank, W. JF - Elektropraktiker. 63 (2009), H. 3 Y1 - 2009 SN - 0013-5569 SP - 218 EP - 222 PB - HUSS-MEDIEN GmbH CY - Berlin ER - TY - JOUR A1 - Kern, Alexander T1 - Überarbeitung der Blitzschutznorm IEC 62305 JF - Elektropraktiker. 63 (2009), H. 4 Y1 - 2009 SN - 0013-5569 SP - 391 EP - 394 ER - TY - JOUR A1 - Schwarzer, Klemens A1 - da Silva, Vieira E. A1 - Hoffschmidt, Bernhard A1 - Schwarzer, T. T1 - A new solar desalination system with heat recovery for decentralised drinking water production JF - Desalination. 248 (2009), H. 1-3 Y1 - 2009 SN - 0011-9164 N1 - Water and Sanitation in International Development and Disaster Relief (WSIDDR) International Workshop Edinburgh, Scotland, UK, 28–30 May 2008 SP - 204 EP - 211 PB - Elsevier CY - Amsterdam ER - TY - BOOK A1 - Dielmann, Klaus-Peter T1 - Integration des CROWN-Systems in die Biogasgewinnung [Elektronische Ressource] : Abschlussbericht / K. Dielmann Y1 - 2009 N1 - Förderkennzeichen BMBF 1780X05 PB - FH Aachen, Fachbereich 10 NOWUM-Energy CY - Jülich ER - TY - JOUR A1 - Pieper, Martin T1 - Vector hyperinterpolation on the sphere JF - Journal of approximation theory. 156 (2009), H. 2 Y1 - 2009 SN - 0021-9045 SP - 173 EP - 186 ER - TY - JOUR A1 - Ewe, Hendrik A1 - Klein, Peter A1 - Pieper, Martin A1 - Füldner, G. T1 - Heat conductivity in sintered aluminium fibers JF - Cellular metals for structural and functional applications : CELLMET 2008 ; proceedings of the International Symposium on Cellular Metals for Structural and Functional Applications held October 8 - 10, 2008 in Dresden, Germany / ed. by Günter Stephani Y1 - 2009 SP - 187 EP - 193 PB - Fraunhofer IFAM CY - Dresden ER - TY - CHAP A1 - Hellmanns, Mark A1 - Hartung, I. A1 - Dilger, Klaus A1 - Böhm, Stefan T1 - Quality assurance of manual guided joining and welding devices T2 - Proceedings of the IIW International Conference on Advances in Welding and Allied Technologies : July 16 - 17, 2009, Singapore Y1 - 2009 SN - 9789810832605 SP - 219 EP - 222 PB - International Institute of Welding CY - Roissy ER - TY - BOOK A1 - Goldbach, Daniel T1 - Zur Verbesserung des Fahrverhaltens von Zugfahrzeug-Anhänger-Gespannen. (Fortschrittberichte VDI. Reihe 12, Verkehrstechnik, Fahrzeugtechnik ; Nr. 703) Y1 - 2009 SN - 978-3-18-370312-8 N1 - Zugl.: Ilmenau, Techn. Univ., Diss., 2009 PB - VDI-Verl. CY - Düsseldorf ER - TY - CHAP A1 - Hartung, I. A1 - Dilger, Klaus A1 - Hellmanns, Mark A1 - Böhme, Stefan T1 - Repair of non-weldable steel structures to extend the life cycle T2 - Proceedings of the IIW International Conference on Advances in Welding and Allied Technologies : July 16 - 17, 2009, Singapore. (Welding in the world ; 53.2009, special issue) Y1 - 2009 SN - 978-981-08-3259-9 SP - 569 EP - 574 PB - Springer CY - Berlin [u.a.] ER - TY - BOOK A1 - Wählisch, Georg T1 - Technisches Zeichnen : Vorlesung und Übungen Y1 - 2009 SN - 978-3-8322-8044-4 PB - Shaker CY - Aachen ER - TY - THES A1 - Betsch, Matthias T1 - Umbau einer Mikroturbine zu einer extern befeuerten Maschine mit Ankopplung an eine Stationäre-Wirbelschichtfeuerung Y1 - 2009 U6 - http://nbn-resolving.de/urn/resolver.pl?nbn:de:gbv:28-diss2009-0166-9 N1 - Diss., Univ. Rostock, 2009 PB - Univ. Rostock, Fakultät für Maschinenbau und Schiffstechnik CY - Rostock ER - TY - JOUR A1 - Borchert, Jörg A1 - Hasenbeck, Marc A1 - Jungbluth, Christian A1 - Schemm, Ralf T1 - Bewertung und Steuerung von Gasspeichern bzw. Gasspeicherscheiben JF - Zeitschrift für Energiewirtschaft N2 - In diesem Artikel werden zunächst einleitend der Gasmarkt Deutschland und der sich daraus ergebende Speicherbedarf skizziert. Folgend wird auf verschiedene Speichernutzen aus betriebswirtschaftlicher Perspektive eingegangen und die in diesem Artikel vorgestellten Bewertungsverfahren einleitend beschrieben. In diesem Artikel werden stochastische Optimierungsmethoden aufgegriffen, die sowohl eine Bewertung der Speicher gegenüber einem Spotpreis, als auch gegenüber einer gesamten Forwardcurve ermöglichen. Hierzu werden zunächst Modelle zur Beschreibung der Marktpreise vorgestellt und anhand empirischer Daten kalibriert. Dann wird eine beispielhafte Speicherscheibe zunächst auf Basis der LeastSquareMonteCarloTechnik gegenüber dem stochastischen mehrfaktoriellen Spotpreismodell bewertet. Hieran schließt sich die Vorstellung der Bewertung sowie des Hedgings gegenüber der Forwardcurve an. Abschließend erfolgt eine vergleichende Gegenüberstellung beider Verfahren. Y1 - 2009 U6 - http://dx.doi.org/10.1007/s12398-009-0033-x SN - 1866-2765 VL - 33 IS - 4 SP - 279 EP - 293 PB - Springer CY - Berlin ER - TY - JOUR A1 - Borchert, Jörg A1 - Hasenbeck, Marc T1 - Bewertung und Steuerung von Kraftwerksscheiben JF - Zeitschrift für Energiewirtschaft Y1 - 2009 U6 - http://dx.doi.org/10.1007/s12398-009-0014-0 SN - 1866-2765 VL - 33 IS - 2 SP - 115 EP - 126 PB - Vieweg CY - Wiesbaden ER - TY - CHAP A1 - Lintzel, P. A1 - Borchert, Jörg ED - Zenke, Ines T1 - Risiken des Handels T2 - Energiehandel in Europa Y1 - 2009 SN - 978-3-406-58373-5 SP - 239 EP - 247 PB - Beck CY - München ET - 2. Aufl. ER - TY - CHAP A1 - Borchert, Jörg A1 - Hintze, D. ED - Zenke, Ines T1 - Der Aufbau von Handelseinheiten T2 - Energiehandel in Europa Y1 - 2009 SN - 978-3-406-58373-5 SP - 393 EP - 410 PB - Beck CY - München ET - 2. Aufl. ER - TY - CHAP A1 - Michels, A. A1 - Borchert, Jörg ED - Zenke, Ines T1 - Beschaffungsstrategien an der Schnittstelle Energiehandel/Vertrieb T2 - Energiehandel in Europa Y1 - 2009 SN - 978-3-406-58373-5 SP - 467 EP - 481 PB - Beck CY - München ET - 2. Aufl. ER - TY - CHAP A1 - Mottaghy, Darius A1 - Majorowicz, Jacek A1 - Rath, Volker T1 - Ground Surface Temperature Histories Reconstructed from Boreholes in Poland: Implications for Spatial Variability T2 - The Polish Climate in the European Context: An Historical Overview Y1 - 2009 SN - 978-90-481-3167-9 U6 - http://dx.doi.org/10.1007/978-90-481-3167-9_17 SP - 375 EP - 387 PB - Springer Science+Business Media CY - Dordrecht ER - TY - JOUR A1 - Mottaghy, Darius A1 - Pechnig, Renate T1 - Numerische 3D Modelle zur Temperaturvorhersage und Reservoirsimulationen JF - BBR - Fachmagazin für Brunnen- und Leitungsbau Y1 - 2009 VL - 60 IS - 10 SP - 44 EP - 51 ER - TY - JOUR A1 - Meskouris, Konstantin A1 - Butenweg, Christoph A1 - Gellert, Christoph T1 - Iterativ verbessert : die RWTH Aachen entwickelt eine Software für einfache Nachweise von Mauerwerksbauten in Erdbebengebieten JF - Deutsches Ingenieur-Blatt : Ingenieurwesen, Bautechnik, Umweltschutz ; Organ der deutschen Ingenieurkammern / Hrsg.: Bundes-Ingenieurkammer e.V. Y1 - 2009 SN - 2365-192X N1 - Printausg. in der Bibliothek Bayernallee vorhanden: 13 Z 842 IS - Heft 5 SP - 31 EP - 36 PB - Rauh Medien GmbH CY - Wandlitz ER - TY - JOUR A1 - Holtschoppen, B. A1 - Butenweg, Christoph A1 - Meskouris, Konstantin T1 - Erdbebensichere Auslegung von Industrieanlagen JF - Der Bauingenieur : die richtungsweisende Zeitschrift im Bauingenieurswesen ; offizielle Zeitschrift der VDI-Gesellschaft Bautechnik Y1 - 2009 SN - 0005-6650 IS - März SP - S9 EP - S14 PB - VDI Fachmedien CY - Düsseldorf ER - TY - JOUR A1 - Holtschoppen, Britta A1 - Butenweg, Christoph A1 - Meskouris, Konstantin T1 - Seismic design of non-structural components in industrial facilities JF - International journal of engineering under uncertainty Y1 - 2009 SN - 0975-4806 VL - Volume 1 SP - 1 EP - 13 ER - TY - JOUR A1 - Meskouris, Konstantin A1 - Butenweg, Christoph A1 - Gellert, Christoph T1 - Einfache Nachweise : einige Beispiele für die Anwendung des Bemessungsprogramms der RWTH Aachen für den Nachweis von Mauerwerksbauten in Erdbebengebieten JF - Deutsches Ingenieur-Blatt : Ingenieurwesen, Bautechnik, Umweltschutz ; Organ der deutschen Ingenieurkammern / Hrsg.: Bundes-Ingenieurkammer e.V. Y1 - 2009 SN - 0946-2422 N1 - Printausgabe in der Bibliothek Bayernallee vorhanden: 13 Z 842 IS - Heft 6 SP - 26 EP - 29 PB - Rauh Medien GmbH CY - Wandlitz ER - TY - CHAP A1 - Gömmel, Andreas A1 - Kob, Malte A1 - Niendorf, Thoralf A1 - Butenweg, Christoph T1 - An approach for numerical calculation of glottal flow during glottal closure T2 - Proceedings / NAG/DAGA 2009, International Conference on Acoustics : Rotterdam, 23 - 26 March 2009 ; [including the 35th German Annual Conference on Acoustics (DAGA)] / [organisers: Acoustical Society of the Netherlands (NAG); German Acoustical Society (DEGA) ...]. Ed. by Marinus M. Boone Y1 - 2009 SN - 978-3-9808659-6-8 SP - 1722 EP - 1725 PB - DEGA CY - Berlin ER - TY - CHAP A1 - Gellert, Christoph A1 - Butenweg, Christoph T1 - Nichtlinearer Erdbebennachweis von Mauerwerksbauten T2 - Erdbeben und Mauerwerk : 11. D-A-CH-Tagung 2009 ; [10./11. September 2009 in Zürich] / SGEB, Swiss Society for Earthquake Engineering and Structural Dynamics; Schweizerischer Ingenieur- und Architektenverein, Fachgruppe für Brückenbau und Hochbau. [Hrsg. Dazio, Alessandro ...] Y1 - 2009 SN - 978-3-03732-021-1 SP - 125 EP - 132 PB - SIA CY - Zürich ER - TY - CHAP A1 - Meskouris, Konstantin A1 - Holler, Stefan A1 - Butenweg, Christoph A1 - Meiners, Daniel T1 - A multiphase model with hypoplastic formulation of the solid phase and its application to earthquake engineering problems T2 - Computational structural dynamics and earthquake engineering / ed. by Manolis Papadrakakis .... (Structures and infrastructures series ; 2) Y1 - 2009 SN - 978-0-415-45261-8 U6 - http://dx.doi.org/10.1201/9780203881637.ch19 SP - 293 EP - 308 PB - CRC Press CY - Boca Raton, Fla. [u.a.] ER - TY - CHAP A1 - Butenweg, Christoph A1 - Gellert, Christoph T1 - Erdbebenberechnung von Mauerwerksbauten nach DIN EN 1998-1 (12.2010) T2 - Mauerwerksbau-Praxis / Schubert; Schneider; Schoch (Hrsg.) Y1 - 2009 SN - 978-3-89932-217-0 SP - 299 EP - 343 PB - Bauwerk CY - Berlin ER - TY - THES A1 - Fleischhaker, Robert T1 - Light propagation in dense and chiral media Y1 - 2009 N1 - Heidelberg, Univ., Diss., 2009 ER - TY - GEN A1 - Butenweg, Christoph A1 - Gellert, Christoph A1 - Reindl, Lukas A1 - Meskouris, Konstantin T1 - A nonlinear method for the seismic safety verification of masonry buildings N2 - In order for traditional masonry to stay a competitive building material in seismically active regions there is an urgent demand for modern, deformation-based verification procedures which exploit the nonlinear load bearing reserves. The Capacity Spectrum Method (CSM) is a widely accepted design approach in the field of reinforced concrete and steel construction. It compares the seismic action with the load-bearing capacity of the building considering nonlinear material behavior with its post-peak capacity. The bearing capacity of the building is calculated iteratively using single wall capacity curves. This paper presents a new approach for the bilinear approximation of single wall capacity curves in the style of EC6/EC8 respectively FEMA 306/FEMA 356 based on recent shear wall test results of the European Collective-Research Project “ESECMaSE”. The application of the CSM to masonry structures by using bilinear approximations of capacity curves as input is demonstrated on the example of a typical German residential home. Y1 - 2009 N1 - COMPDYN 2009 - 2nd International Conference on Computational Methods in Structural Dynamics & Earthquake Engineering. Isles of Rhodes, Greece, June 22-24,2009. PB - National Technical University of Athens CY - Athen ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Heinrichs, Uwe A1 - Kozerke, Sebastian A1 - Utting, Jane A1 - Kob, Malte A1 - Butenweg, Christoph A1 - Boesiger, Peter A1 - Niendorf, Thoralf T1 - Feasibility of Cardiac Gating Free of Interference With Electro-Magnetic Fields at 1.5 Tesla, 3.0 Tesla and 7.0 Tesla Using an MR-Stethoscope JF - Investigative Radiology KW - phonocardiogram KW - electrocardiogram KW - cardiac gating KW - high field MR imaging KW - cardiovascular MR imaging Y1 - 2009 U6 - http://dx.doi.org/10.1097/RLI.0b013e3181b4c15e SN - 1536-0210 (online) SN - 0020-9996 (gedruckt) VL - 44 IS - 9 SP - 539 EP - 547 PB - Lippincott Williams & Wilkins ; (via Ovid) CY - Philadelphia, Pa ER -