TY - CHAP A1 - Duran Paredes, Ludwin A1 - Mottaghy, Darius A1 - Herrmann, Ulf A1 - Groß, Rolf Fritz T1 - Online ground temperature and soil moisture monitoring of a shallow geothermal system with non-conventional components T2 - EGU General Assembly 2020 N2 - We present first results from a newly developed monitoring station for a closed loop geothermal heat pump test installation at our campus, consisting of helix coils and plate heat exchangers, as well as an ice-store system. There are more than 40 temperature sensors and several soil moisture content sensors distributed around the system, allowing a detailed monitoring under different operating conditions.In the view of the modern development of renewable energies along with the newly concepts known as Internet of Things and Industry 4.0 (high-tech strategy from the German government), we created a user-friendly web application, which will connect the things (sensors) with the open network (www). Besides other advantages, this allows a continuous remote monitoring of the data from the numerous sensors at an arbitrary sampling rate.Based on the recorded data, we will also present first results from numerical simulations, taking into account all relevant heat transport processes.The aim is to improve the understanding of these processes and their influence on the thermal behavior of shallow geothermal systems in the unsaturated zone. This will in turn facilitate the prediction of the performance of these systems and therefore yield an improvement in their dimensioning when designing a specific shallow geothermal installation. Y1 - 2020 N1 - EGU General Assembly 2020, Online, 4–8 May 2020 ER - TY - CHAP A1 - Sattler, Johannes Christoph A1 - Chico Caminos, Ricardo Alexander A1 - Ürlings, Nicolas A1 - Dutta, Siddharth A1 - Ruiz, Victor A1 - Kalogirou, Soteris A1 - Ktistis, Panayiotis A1 - Agathokleous, Rafaela A1 - Jung, Christian A1 - Alexopoulos, Spiros A1 - Atti, Vikrama Naga Babu A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Operational experience and behaviour of a parabolic trough collector system with concrete thermal energy storage for process steam generation in Cyprus T2 - AIP Conference Proceedings N2 - As part of the transnational research project EDITOR, a parabolic trough collector system (PTC) with concrete thermal energy storage (C-TES) was installed and commissioned in Limassol, Cyprus. The system is located on the premises of the beverage manufacturer KEAN Soft Drinks Ltd. and its function is to supply process steam for the factory's pasteurisation process [1]. Depending on the factory's seasonally varying capacity for beverage production, the solar system delivers between 5 and 25 % of the total steam demand. In combination with the C-TES, the solar plant can supply process steam on demand before sunrise or after sunset. Furthermore, the C-TES compensates the PTC during the day in fluctuating weather conditions. The parabolic trough collector as well as the control and oil handling unit is designed and manufactured by Protarget AG, Germany. The C-TES is designed and produced by CADE Soluciones de Ingeniería, S.L., Spain. In the focus of this paper is the description of the operational experience with the PTC, C-TES and boiler during the commissioning and operation phase. Additionally, innovative optimisation measures are presented. Y1 - 2020 U6 - https://doi.org/10.1063/5.0029278 N1 - SOLARPACES 2019: International Conference on Concentrating Solar Power and Chemical Energy Systems, 1–4 October 2019, Daegu, South Korea IS - 2303 SP - 140004-1 EP - 140004-10 ER - TY - CHAP A1 - Hoffschmidt, Bernhard A1 - Alexopoulos, Spiros A1 - Göttsche, Joachim A1 - Sauerborn, Markus A1 - Kaufhold, O. T1 - High Concentration Solar Collectors T2 - Comprehensive Renewable Energy (Second Edition) / Volume 3: Solar Thermal Systems: Components and Applications N2 - Solar thermal concentrated power is an emerging technology that provides clean electricity for the growing energy market. To the solar thermal concentrated power plant systems belong the parabolic trough, the Fresnel collector, the solar dish, and the central receiver system. For high-concentration solar collector systems, optical and thermal analysis is essential. There exist a number of measurement techniques and systems for the optical and thermal characterization of the efficiency of solar thermal concentrated systems. For each system, structure, components, and specific characteristics types are described. The chapter presents additionally an outline for the calculation of system performance and operation and maintenance topics. One main focus is set to the models of components and their construction details as well as different types on the market. In the later part of this article, different criteria for the choice of technology are analyzed in detail. KW - Central receiver system KW - Concentrated solar collector KW - Solar dish KW - Solar concentration Y1 - 2022 SN - 978-0-12-819734-9 U6 - https://doi.org/10.1016/B978-0-12-819727-1.00058-3 SP - 198 EP - 245 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Henriques, A. A1 - Jurado, B. A1 - Grieser, M. A1 - Denis-Petit, D. A1 - Chiron, T. A1 - Gaudefroy, L. A1 - Glorius, J. A1 - Langer, Christoph A1 - Litvinov, Yu. A. A1 - Mathieu, L. A1 - Meot, V. A1 - Perez-Sanchez, R. A1 - Pibernat, J. A1 - Reifarth, R. A1 - Roig, O. A1 - Thomas, B. A. A1 - Thomas, B. A. A1 - Thomas, J. C. A1 - Tsekhanovich, I. T1 - Indirect measurements of neutron cross-secti at heavy-ion storage rings JF - Journal of Physics: Conference Series N2 - Cross sections for neutron-induced reactions of short-lived nuclei are essential for nuclear astrophysics since these reactions in the stars are responsible for the production of most heavy elements in the universe. These reactions are also key in applied domains like energy production and medicine. Nevertheless, neutron-induced cross-section measurements can be extremely challenging or even impossible to perform due to the radioactivity of the targets involved. Indirect measurements through the surrogate-reaction method can help to overcome these difficulties. The surrogate-reaction method relies on the use of an alternative reaction that will lead to the formation of the same excited nucleus as in the neutron-induced reaction of interest. The decay probabilities (for fission, neutron and gamma-ray emission) of the nucleus produced via the surrogate reaction allow one to constrain models and the prediction of the desired neutron cross sections. We propose to perform surrogate reaction measurements in inverse kinematics at heavy-ion storage rings, in particular at the CRYRING@ESR of the GSI/FAIR facility. We present the conceptual idea of the most promising setup to measure for the first time simultaneously the fission, neutron and gamma-ray emission probabilities. The results of the first simulations considering the 238U(d,d') reaction are shown, as well as new technical developments that are being carried out towards this set-up. Y1 - 2020 U6 - https://doi.org/10.1088/1742-6596/1668/1/012019 VL - 1668 IS - Art. 012019 PB - IOP CY - Bristol ER - TY - JOUR A1 - Fleischhaker, Robert A1 - Evers, Jörg A1 - Dey, Tarak N. T1 - Phase modulation induced by cooperative effects in electromagnetically induced transparency JF - Physical Review A - Atomic, molecular, and optical physics N2 - We analyze the influence of dipole-dipole interactions in an electromagnetically induced transparency set up for a density at the onset of cooperative effects. To this end, we include mean-field models for the influence of local-field corrections and radiation trapping into our calculation. We show both analytically and numerically that the polarization contribution to the local field strongly modulates the phase of a weak pulse. We give an intuitive explanation for this local-field-induced phase modulation and demonstrate that it distinctively differs from the nonlinear self-phase-modulation that a strong pulse experiences in a Kerr medium. Y1 - 2010 U6 - https://doi.org/10.1103/PhysRevA.82.013815 SN - 1050-2947 VL - 82 IS - 1 PB - AIP Publishing CY - Melville, NY ER - TY - CHAP A1 - Atmane, Ilias A1 - Hirech, Kamal A1 - Kassmi, K. A1 - Mahdi, Zahra A1 - Alexopoulos, Spiros A1 - Schwarzer, Klemens A1 - Chayeb, H. A1 - Bachiri, Najib ED - Omrane, Amina ED - Kassmi, Khalil ED - Akram, Muhammad Wasim ED - Khanna, Ashish ED - Mostafiz, Imtiaz T1 - Design and realization of a pilot solar desalination plant in Douar El Hamri in the province of Berkane (Morocco) T2 - Sustainable entrepreneurship, renewable energy-based projects, and digitalization N2 - Producing fresh water from saline water has become one of the most difficult challenges to overcome especially with the high demand and shortage of fresh water. In this context, as part of a collaboration with Germany, the authors propose a design and implementation of a pilot multi-stage solar desalination system (MSD), remotely controlled, at Douar Al Hamri in the rural town of Boughriba in the province of Berkane, Morocco. More specifically, they present their contribution on the remote control and supervision system, which makes the functioning of the MSD system reliable and guarantees the production of drinking water for the population of Douar. The results obtained show that the electronic cards and computer communication software implemented allow the acquisition of all electrical (currents, voltages, powers, yields), thermal (temperatures of each stage), and meteorological (irradiance and ambient temperature), remote control and maintenance (switching on, off, data transfer). By comparing with the literature carried out in the field of solar energy, the authors conclude that the MSD and electronic desalination systems realized during this work represent a contribution in terms of the reliability and durability of providing drinking water in rural and urban areas. Y1 - 2020 SN - 9781000292541 (E-Book) SN - 9781003097921 (E-Book) SN - 9780367468378 (Hardcover) PB - CRC Press CY - Boca Raton, Fa. ER - TY - GEN A1 - Dieringer, Matthias A. A1 - Renz, Wolfgang A1 - Lindel, Tomasz Dawid A1 - Seifert, Frank A1 - Frauenrath, Tobias A1 - Waiczies, Helmar A1 - von Knobelsdorff-Brenkhoff, Florian A1 - Santoro, Davide A1 - Hoffmann, Werner A1 - Ittermann, Bernd A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - 4CH TX/RX Surface Coil for 7T: Design, Optimization and Application for Cardiac Function Imaging T2 - 2010 ISMRM-ESMRMB joint annual meeting N2 - Practical impediments of ultra high field cardiovascular MR (CVMR) can be catalogued in exacerbated magnetic field and radio frequency (RF) inhomogeneities, susceptibility and off-resonance effects, conductive and dielectric effects in tissue, and RF power deposition constraints, which all bear the potential to spoil the benefit of CVMR at 7T. Therefore, a four element cardiac transceive surface coil array was developed. Cardiac imaging provided clinically acceptable signal homogeneity with an excellent blood myocardium contrast. Subtle anatomic structures, such as pericardium, mitral and tricuspid valves and their apparatus, papillary muscles, and trabecles were accurately delineated. Y1 - 2010 SN - 1545-4428 N1 - ISMRM-ESMRMB joint annual meeting, 1 - 7 May 2010, Stockholm, Sweden ER - TY - JOUR A1 - Geimer, Konstantin A1 - Sauerborn, Markus A1 - Hoffschmidt, Bernhard A1 - Schmitz, Mark A1 - Göttsche, Joachim T1 - Test facility for absorber specimens of solar tower power plants JF - Advances in Science and Technology N2 - The Solar-Institute Jülich (SIJ) has initiated the construction of the first and only German solar tower power plant and is now involved in the accompanying research. The power plant for experimental and demonstration purposes in the town of Jülich started supplying electric energy in the beginning of 2008. The central receiver plant features as central innovation an open volumetric receiver, consisting of porous ceramic elements that simultaneously absorb the concentrated sunlight and transfer the heat to ambient air passing through the pores so that an average temperature of 680°C is reached. The subsequent steam cycle generates up to 1.5 MWe. A main field of research at the SIJ is the optimization of the absorber structures. To analyze the capability of new absorber specimens a special test facility was developed and set up in the laboratory. A high-performance near-infrared radiator offers for single test samples a variable and repeatable beam with a power of up to 320 kW/m² peak. The temperatures achieved on the absorber surface can reach more than 1000°C. To suck ambient air through the open absorber - like on the tower - it is mounted on a special blower system. An overview about the test facility and some recent results will be presented. Y1 - 2010 U6 - https://doi.org/10.4028/www.scientific.net/AST.74.266 N1 - 5th Forum on New Materials : CIMTEC 2010, Montecatini Terme, Italy 13-18 June 2010. Part C VL - 74 SP - 266 EP - 271 PB - Trans Tech Publications CY - Baech ER - TY - JOUR A1 - Kern, Alexander A1 - Frentzel, Ralf A1 - Behrens, Jörg T1 - Simulation of the transient voltages in the auxiliary power network of a large power plant in case of a direct lightning strike to the high-voltage overhead transmission line N2 - Large power plants can be endangered by lightning strikes with possible consequences regarding their safety and availability. A special scenario is a lightning strike to the HV overhead transmission line close to the power plant's connection to the power grid. If then additionally a so-called shielding failure of the overhead ground wire on top of the overhead transmission line is assumed, i.e. the lightning strikes directly into a phase conductor, this is an extreme electromagnetic disturbance. The paper deals with the numerical simulation of such a lightning strike and the consequences on the components of the power plant's auxiliary power network connected to different voltage levels. KW - power generation KW - surges KW - conductors KW - arresters KW - power transmission lines KW - lightning Y1 - 2010 SN - 978-88-905519-0-1 U6 - https://doi.org/10.1109/ICLP.2010.7845756 N1 - 2010 30th International Conference on Lightning Protection (ICLP), 13-17 Sept. 2010, Cagliari, Italy SP - 749-1 EP - 749-7 PB - IEEE CY - New York ER - TY - JOUR A1 - Bouquegneau, Christian A1 - Kern, Alexander A1 - Rousseau, Alain T1 - Lightning safety guidelines N2 - This paper introduces lightning to the layman, noting the right behaviour in front of thunderstorms as well as protective measures against lightning. It also contributes to the prevention of lightning injuries and damages. This report was prepared by the authors inside the AHG1 Group for IEC TC81 (Lightning Protection). Y1 - 2010 N1 - Ground´2010 & 4th LPE, International Conference on Grounding and Earthing & 4th International Conference on Lightning Physics and Effects, Salvador - Brazil, November, 2010 ER - TY - JOUR A1 - Kern, Alexander A1 - Klöters, Georg A1 - Pferdemenges, Jörg T1 - Optimised protection against lightning for the signalling and safety systems of level crossings on non-electrified railway lines JF - RTR : European Rail Technology Review Y1 - 2010 SN - 0079-9548 VL - 50 IS - 2 PB - DVV Media Group CY - Hamburg ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Probability of lightning strikes to air-terminations of structures using the electro-geometrical model theory and the statistics of lightning current parameters N2 - Planning the air-terminations for a structure to be protected the use of the rolling-sphere method (electro-geometrical model) is the best way from the physics of lightning point-of-view. Therefore, international standards prefer this method. However, using the rolling-sphere method only results in possible point-of-strikes on a structure without giving information about the probability of strikes at the individual points compared to others. KW - atmospheric modeling KW - probability distribution KW - lightning protection KW - standards KW - planning Y1 - 2010 SN - 978-88-905519-0-1 U6 - https://doi.org/10.1109/ICLP.2010.7845757 N1 - 2010 30th International Conference on Lightning Protection (ICLP), 13-17 Sept. 2010, Cagliari, Italy SP - 750-1 EP - 750-8 PB - IEEE CY - New York ER -