TY - JOUR
A1 - Rosenauer, A.
A1 - Oberst, W.
A1 - Litvinov, D.
A1 - Gerthsen, D.
A1 - Förster, Arnold
A1 - Schmidt, R.
T1 - Structural and Chemical Investigation of In-0.6Ga0.4As Stranski-Krastanow Layers Burried in GaAs by Transmission Electron Microscopy
JF - Physical Review B. 61 (2000), H. 12
Y1 - 2000
SN - 1095-3795
SP - 8276
EP - 8288
ER -
TY - JOUR
A1 - Thielemann, Frank
T1 - Das Management von Innovationen aus betriebswirtschaftlicher Sicht
JF - Humanität - Wandel - Utopie / Bernd Rebe (Hrsg.). Mit Beitr. von Ute Daniel
Y1 - 2000
N1 - Cloppenburger Wirtschaftsgespräche ; Bd. 9
SP - 33
EP - 64
PB - Olms
CY - Hildesheim
ER -
TY - JOUR
A1 - Thielemann, Frank
A1 - Lang, Franz Peter
T1 - Wissensmanagement und neue Informationstechnologie . Lang, Franz Peter; Thielemann, Frank
JF - Veränderungsmanagement in der Sozialwirtschaft / Bernd Maelicke (Hrsg.)
Y1 - 2000
SN - 3-7890-6738-5
N1 - Inhaltsverzeichnis
SP - 132
EP - 172
PB - Nomos-Verl.-Ges.
CY - Baden-Baden
ER -
TY - BOOK
A1 - Thielemann, Frank
T1 - Kompetenzentwicklung im Mittelstand - das Beispiel Kompetenz-Entwicklungs-Center / hrsg. von Frank Thielemann
Y1 - 2000
SN - 3-89275-031-9
N1 - Wirtschaftswissenschaftliche Studien ; 20
PB - MA, Akademie-Verl.- und Druck-Ges.
CY - Essen
ER -
TY - BOOK
A1 - Thielemann, Frank
T1 - Bilanzen - ein komprimierter Überblick : Intensivkurs zum betrieblichen Rechnungswesen. 2., überarb. Aufl.
Y1 - 2000
SN - 3-89275-026-2
PB - MA, Akademie-Verl.- und Druck-Ges.
CY - Essen
ER -
TY - JOUR
A1 - Thielemann, Frank
A1 - Lüdtke, C.
T1 - Einfluß des KonTraG im Unternehmensbereich
JF - Wirtschafts-Nachrichten. 45 (2000), H. 8
Y1 - 2000
SN - 1436-5588
SP - 10
EP - f.
ER -
TY - JOUR
A1 - Thielemann, Frank
A1 - Lüdtke, C.
T1 - Risikomanagement - Aufbau eines Frühwarnsystems
JF - Wirtschafts-Nachrichten. 45 (2000), H. 12
Y1 - 2000
SN - 1436-5588
SP - 14
EP - ff
ER -
TY - JOUR
A1 - Hoffschmidt, Bernhard
T1 - Keramische Mischer : Überhitzung ausgeschlossen
JF - Nachrichten : Magazin des Deutschen Zentrums für Luft- und Raumfahrt / DLR (2000)
Y1 - 2000
SN - 0937-0420
SP - 26
EP - 27
ER -
TY - JOUR
A1 - Hoffschmidt, Bernhard
A1 - Krüger, D.
A1 - Hennecke, K.
T1 - Results from parabolic trough systems for process heat at the DLR Cologne / D. Krüger ; B. Hoffschmidt ; K. Hennecke ...
JF - Solar thermal 2000 : proceedings of the 10th SolarPACES International Symposium on Solar Thermal Concentrating Technologies, Sydney, Australia, 8 - 10 March 2000 ; part of the
Y1 - 2000
N1 - International Symposium on Solar Thermal Concentrating Technologies <10, 2000, Sydney>
SP - 113
EP - 120
CY - Sydney
ER -
TY - JOUR
A1 - Dielmann, Klaus-Peter
T1 - Mikro-Gasturbine als Kleinst-BHKW-Bericht über Einsatzerfahrungen
JF - Fünftes VWEW-Fachforum Nahwärme 2000 : Wärmedirekt-Service der Energiedienstleistungsunternehmen mit Fachausstellung Nahwärmetechnik 2000 ; 4. und 5. Mai 2000 in Halle
Y1 - 2000
N1 - Fachforum Nahwärme <5, 2000, Halle, Saale> ; Verlags- und Wirtschaftsgesellschaft der Elektrizitätswerke
SP - 5.1
EP - 5.22
PB - VWEW
CY - [Frankfurt, Main]
ER -
TY - JOUR
A1 - Dielmann, Klaus-Peter
A1 - Schieke, W.
T1 - Mikro-Gasturbinen : Aufbau und Anwendung
JF - Gasturbinen für kombinierte Gas-Dampfturbinenanlagen : und Workshop Advanced Power Plant Processes for Solid Fuels Focussing on Combined Cycles ; Tagung Essen, 13. und 14. September 2000 / VDI-Gesellschaft Energietechnik. - (VDI-Berichte ; 1566)
Y1 - 2000
SN - 3-18-091566-8
N1 - Workshop Advanced Power Plant Processes for Solid Fuels Focussing on Combined Cycles <2000, Essen>
SP - 187
EP - 210
PB - VDI-Verl.
CY - Düsseldorf
ER -
TY - JOUR
A1 - Dielmann, Klaus-Peter
A1 - Ihle, R.
T1 - Mikroturbinen : neue Chancen der Kraft-Wärme-(Kälte-)Kopplung im Leistungsbereich 30 - 200 kW(ind el) / R. Ihle ; K. Dielmann
JF - Integrierte Energiesysteme : Chancen im Wettbewerb ; Tagung Nürnberg, 4. und 5. April 2000 / VDI-Gesellschaft Energietechnik. - (VDI-Berichte ; 1539)
Y1 - 2000
SN - 3-18-091539-0
SP - 245
EP - 266
PB - VDI-Verl.
CY - Düsseldorf
ER -
TY - JOUR
A1 - Bansal, N. K.
A1 - Müller, C.
A1 - Vieira, M. E.
A1 - Faber, Christian
A1 - Schwarzer, Klemens
T1 - Thermal performance of a rock bed storage system
JF - Proceedings : University of Stuttgart, Germany, August 28th until September 1st, 2000 / Terrastock 2000, 8th International Conference on Thermal Energy Storage. Ed.: M. Benner ... - Vol. 1
Y1 - 2000
SN - 3-9805274-1-7
N1 - Terrastock <2000, Stuttgart> ; Institut für Thermodynamik und Wärmetechnik
SP - 433
EP - 439
PB - Inst. für Thermodynamik und Wärmetechnik
CY - Stuttgart
ER -
TY - JOUR
A1 - Förster, Arnold
T1 - Resonant tunneling diodes operating as modern quantum transport devices
JF - Proceedings of the Tenth International Workshop on the Physics of Semiconductor Devices : (December 14 - 18, 1999) / ed.: Vikram Kumar ... - Vol. 2
Y1 - 2000
SN - 81-7023-998-2
N1 - International Workshop on the Physics of Semiconductor Devices <10, 1999, Delhi>
SP - 966
EP - 966
PB - Allied Publ.
CY - New Delhi [u.a.]
ER -
TY - CHAP
A1 - Claßen, R.
A1 - Dören, Horst-Peter
A1 - Codani, L.
A1 - Watermeyer, Klaus
T1 - Begleitende Untersuchungen beim Löten mit vorübergehend flüssiger Phase (TL PB) einschließlich Aktivkomponente an Verbindungen verschiedener Kupfer- und Kohlenstoffwerkstoffe (CFC).
T2 - Fortschritte in der Metallographie. Vortragstexte der 33. Metallographie-Tagung, 15.-17. September 1999 in Rostock. Hrsg. Gerhard Schneider... Praktische Metallographie. Sonderband 31.
Y1 - 2013
SP - 97
EP - 104
PB - Werkstoff-Informationsgesellschaft
CY - Frankfurt
ER -
TY - BOOK
A1 - Gümpel, Paul
A1 - Arlt, Norbert
A1 - Dören, Horst-Peter
A1 - Heimann, Winfried
A1 - Kiesheyer, H.
A1 - Schmitz, Karl W.
A1 - Uhlig, Georg
T1 - Rostfreie Stähle. Grundwissen, Konstruktions- und Verarbeitungsweise = Stainless steels. 2., aktualis. Aufl. Kontakt & Studium. Bd. 493
Y1 - 2000
SN - 3-8169-1735-6
PB - Expert-Verl.
CY - Renningen
ER -
TY - THES
A1 - Kuperjans, Isabel
T1 - Verfahren zur Analyse und Bewertung industrieller Energieanlagen
Y1 - 2000
N1 - Aachen, Techn. Hochsch., Diss., 2000
CY - Aachen
ER -
TY - JOUR
A1 - Kuperjans, Isabel
A1 - Starke, M.
A1 - Esser, J.
A1 - [u.a.],
T1 - Analyse und Konzeption von Energieanlagen unter ökologischen, wirtschaftlichen und technischen Gesichtspunkten
JF - WLB : Umwelttechnik für Industrie und Kommune
Y1 - 2000
SN - 0341-2679
VL - 44
IS - 11/12
SP - 26
EP - 29
ER -
TY - JOUR
A1 - Kuperjans, Isabel
A1 - Esser, J.
A1 - Meyer, Jörg
A1 - Donner, O.
T1 - Gestaltung und Bewertung von Energieanlagen unter ökologischen, wirtschaftlichen und technischen Gesichtspunkten
JF - Umweltwirtschaftsforum : UWF
Y1 - 2000
SN - 0943-3481
VL - 8
IS - 3
SP - 53
EP - 58
ER -
TY - CHAP
A1 - Zischank, Wolfgang J.
A1 - Kern, Alexander
A1 - Frentzel, Ralf
A1 - Heidler, Fridolin
A1 - Seevers, M.
T1 - Assessment of the lightning transient coupling to control cables interconnecting structures in large industrial facilities and power plants
N2 - Large industrial facilities and power plants often require a huge number fo information and control cables between the differnet structures. These I&C-cables can be routed in reinforced concrete cable ducts or in isolated buried cable runs. KTA 2206 is the German lightning protection standard for nuclear power plants. During the last several years considerable effort has been made to revise this standard. Despite the well established principles and design guidelines for the construction of the lightning protection system, this standard puts special emphasis on the coupling of transient overvoltages to I&C-cables.
KW - Blitzschutz
KW - Elektromagnetische Kopplung
KW - Überspannung
KW - Kraftwerke
KW - Industrieanlagen
KW - Lightning
KW - current distribution
KW - electromagnetic coupling
KW - overvoltages
Y1 - 2000
ER -
TY - CHAP
A1 - Dielmann, Klaus-Peter
A1 - Schieke, Wolf
T1 - Mikrogasturbinen - Aufbau und Anwendungen
N2 - Mikrogasturbinen: Funktion, Aufbau, Hersteller, Bauformen, Rekuperatorparameter, Besonderheit der Konstruktion, Regelung, Regelbarkeit, Vergleich mit anderen Systemen, Wirkungs- und Nutzungsgrade, Schadstoffemissionen, Nutzung in Kraft-Wärme-Kopplung, Kraft-Wärme-Kälte-Kopplung
KW - Gasturbine
KW - Mikrogasturbine
KW - Micro turbine
Y1 - 2000
ER -
TY - THES
A1 - Butenweg, Christoph
T1 - Bemessung und Optimierung von Stahlbetontragwerken unter vorwiegend ruhender Belastung mit der Methode der finiten Elemente. (Fortschritt-Berichte VDI : Reihe 4, Bauingenieurwesen ; 160)
Y1 - 2000
SN - 3-18-316004-8
N1 - Dissertation, Universität Essen, 1999
PB - VDI-Verl.
CY - Düsseldorf
ER -
TY - JOUR
A1 - Kern, Alexander
A1 - Krichel, Frank
A1 - Neskakis, Apostolos
A1 - Müller, Klaus-Peter (u.a.)
T1 - Lightning protection design of a renewable energy hybrid-system without power mains connection
Y1 - 2001
N1 - International Conference on Renewable Energies for Islands <2001, Crete>
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Mikulics, M.
A1 - Marso, M.
A1 - Adam, R.
T1 - Low-temperature-grown MBE GaAs for terahertz photomixers. Mikulics, M.; Marso, M.; Adam, R.; Fox, A.; Buca, D.; Förster, A.; Kordos, P.; Xu, Y.; Sobolewski, R.
JF - 2001 Symposium on Electron Devices for Microwave and Optoelectronic Applications ; [Vienna University of Technology, Institute of Electrical Measurements and Circuit Design, 15 - 16 November 2001, Vienna, Austria ; proceedings] / EDMO 2001. Organised by: Institute of Electrical Measurements and Circuit Design, Vienna University of Technology, Austria. With technical co-sponsorship from IEEE Electron Devices Society
Y1 - 2001
SN - 078037049X
N1 - IEEE catalog number: 01TH8567
SP - 155
EP - 155
PB - IEEE Operations Center
CY - Piscataway, NJ
ER -
TY - JOUR
A1 - Krafft, B.
A1 - Förster, Arnold
A1 - Hart, A. van der
A1 - Schäpers, T.
T1 - Control of Aharonov-Bohm oscillations in a AlGaAs/GaAs ring by asymmetric and symmetric gate biasing
JF - Physica E: Low-dimensional Systems and Nanostructures. 9 (2001), H. 4
Y1 - 2001
SN - 1386-9477
SP - 635
EP - 641
ER -
TY - JOUR
A1 - Vitusevich, S. A.
A1 - Förster, Arnold
A1 - Lüth, H.
A1 - Belyaev, A. E.
A1 - Danylyuk, S. V.
A1 - Konakova, R. V.
A1 - Sheka, D. I.
T1 - Resonant spectroscopy of electric-field-induced superlattices
JF - Journal of Applied Physics. 90 (2001), H. 6
Y1 - 2001
SN - 1089-7550
U6 - http://dx.doi.org/10.1063/1.1392956
SP - 2857
EP - 2861
ER -
TY - JOUR
A1 - Stock, J.
A1 - Malindretos, J.
A1 - Indlekofer, K.M.
A1 - Pöttgens, Michael
A1 - Förster, Arnold
A1 - Lüth, Hans
T1 - A Vertical Resonant Tunneling Transistor for Application in Digital Logic Circuits
JF - IEEE Transactions on Electron Devices (T-ED). 48 (2001), H. 6
Y1 - 2001
SN - 0018-9383
SP - 1028
EP - 1032
ER -
TY - BOOK
A1 - Schwarzer, Klemens
A1 - Müller, Christoph
T1 - Entwicklung und Optimierung eines neuartigen Meer- und Brackwasser-Entsalzungssystems : Schlussbericht
Y1 - 2001
PB - Fachhochschule Aachen
CY - Aachen
ER -
TY - BOOK
A1 - Schwarzer, Klemens
A1 - Müller, Christoph
T1 - Entwicklung und Optimierung eines neuartigen Meer- und Brackwasser-Entsalzungssystems : kurze Darstellung zu den Rahmenbedingungen (nach Anlage 2 zu Nr.3.2 BNBest-BMBF 98) ; Schlussbericht
Y1 - 2001
N1 - Fachbereich Energie- und Umweltschutz-Technik
PB - Fachhochschule Aachen
CY - Jülich
ER -
TY - JOUR
A1 - Schwarzer, Klemens
A1 - Wemhöner, C.
T1 - Erfahrungen mit dem Betrieb von kleinen thermischen Solaranlagen
JF - Solarthermie : Auslegung, Anwendung, technische Regeln ; Tagung Gelsenkirchen, 7. März 2001 / VDI-Gesellschaft Energietechnik. - (VDI-Berichte ; 1584)
Y1 - 2001
SN - 3-18-091584-6
N1 - Gesellschaft Energietechnik
SP - 167
EP - 184
PB - VDI-Verl.
CY - Düsseldorf
ER -
TY - JOUR
A1 - Schwarzer, Klemens
A1 - Silva, Maria Eugênia Vieira da
A1 - Faber, Christian
A1 - Müller, Christoph
T1 - Solar thermal desalination system with heat recovery
JF - Desalination. 137 (2001), H. 1-3
Y1 - 2001
SN - 0011-9164
SP - 23
EP - 29
ER -
TY - BOOK
A1 - Schwarzer, Klemens
A1 - Müller, Christoph
T1 - Entwicklung und Optimierung eines neuartigen Meer- und Brackwasser-Entsalzungssystems : Schlußbericht ; kurze Darstellung zu den Rahmenbedingungen ... ; Projektdauer: 1.9.1999 bis 28.4.2001 / Projektleitung: Klemens Schwarzer. Projektingenieur: Christoph Müller
Y1 - 2001
N1 - Förderkennzeichen BMBF 1708499.
PB - [Fachhochschule]
CY - [Aachen]
ER -
TY - JOUR
A1 - Faber, Christian
T1 - Zukunftsfähigkeit als Leitbild für die Ziele des Solar-Instituts Jülich, SIJ
JF - Farbe bekennen - für ein weltoffenes, solidarisches NRW / Landesarbeitsgemeinschaft von Dritte-Welt-Zentren und -Koordinationsstellen in NRW (LAG3W) (Hg.). Red.: Petra Leber
Y1 - 2001
SN - 3-8258-5843-X
N1 - (Studien zur Entwicklungsökonomie ; 16)
SP - 119
EP - 122
PB - Lit
CY - Münster [u.a.]
ER -
TY - JOUR
A1 - Thielemann, Frank
A1 - Lüdtke, C.
T1 - Balanced Scorecard - Von der Vision zur Strategie
JF - Wirtschafts-Nachrichten. 46 (2001), H. 9
Y1 - 2001
SN - 1436-5588
SP - 10
EP - f.
ER -
TY - JOUR
A1 - Dielmann, Klaus-Peter
T1 - Mikrogasturbinen : Technik und Anwendung
JF - BWK : das Energie-Fachmagazin . 53 (2001), H. 6
Y1 - 2001
SN - 0006-9612
N1 - 2. ISSN: 1618-193X
SP - 6
EP - 9
ER -
TY - JOUR
A1 - Hoffschmidt, Bernhard
A1 - Fernandez, V.
A1 - Konstandopoulus, A. G.
T1 - Development of ceramic volumetric receiver technology
JF - Forschungsbericht : DLR FB. 10 (2001)
Y1 - 2001
SN - 0939-2963
N1 - 2. ISSN: 1434-8454 ; Kölner Sonnenkolloquium <5, 2001, Köln> ; Solar thermal power plants and solar chemical processes : advances and perspectives for international cooperation
SP - 51
EP - 61
ER -
TY - JOUR
A1 - Hoffschmidt, Bernhard
A1 - Buck, R.
A1 - Fend, Thomas
T1 - Porous materials as volumetric solar receivers : experimental approach towards a detailed characterisation of instability problems / R. Buck ; T. Fend ; B. Hoffschmidt ...
JF - Forschungsbericht : DLR FB. 10 (2001)
Y1 - 2001
SN - 0939-2963
N1 - 2. ISSN: 1434-8454 ; Kölner Sonnenkolloquium <5, 2001, Köln> ; Solar thermal power plants and solar chemical processes : advances and perspectives for international cooperation
SP - 71
EP - 72
ER -
TY - JOUR
A1 - Hoffschmidt, Bernhard
A1 - Riffelmann, K.-J.
A1 - Krödel, M.
A1 - Rietbrock, P.
T1 - PHITREC - pressurized volumetric air receiver for high temperature solar applications / K.-J. Riffelmann ; B. Hofschmidt ...
JF - Forschungsbericht : DLR FB. 10 (2001)
Y1 - 2001
SN - 0939-2963
N1 - 2. ISSN: 1434-8454 ; Kölner Sonnenkolloquium <5, 2001, Köln> ; Solar thermal power plants and solar chemical processes : advances and perspectives for international cooperation
SP - 73
EP - 74
ER -
TY - JOUR
A1 - Barsov, S.
A1 - Bechstedt, U.
A1 - Hardt, Arno
T1 - ANKE, a new facility for medium energy hadron physics at COSY-Jülich / S. Barsov [u.a.]
JF - Nuclear instruments and methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. Vol. 462, iss. 3
Y1 - 2001
SN - 0167-5087 (Print) ; 0168-9002 (E-journal)
SP - 364
EP - 381
ER -
TY - BOOK
A1 - Gümpel, Paul
A1 - Arlt, Norbert
A1 - Dören, Horst-Peter
A1 - Heimann, Winfried
A1 - Kiesheyer, Heinrich
A1 - Schmitz, Karl W.
A1 - Uhlig, Georg
T1 - Rostfreie Stähle : Grundwissen, Konstruktions- und Verarbeitungshinweise. 3. Aufl. Kontakt & Studium. Bd. 493
Y1 - 2001
SN - 3-8169-1735-6
PB - expert Verl.
CY - Renningen
ER -
TY - CHAP
A1 - Kuperjans, Isabel
A1 - Augenstein, Eckardt
T1 - „EUSEBIA – Software zur Analyse und Verbesserung der betrieblichen Energiewirtschaft
T2 - Optimierung in der Energieversorgung : Tagung Veitshöchheim, 9. und 10. Oktober 2001. - (VDI-Berichte ; 1627)
Y1 - 2001
SN - 3-18-091627-3
SP - 267
EP - 268
PB - VDI-Verl.
CY - Düsseldorf
ER -
TY - CHAP
A1 - Augenstein, Eckardt
A1 - Kuperjans, Isabel
T1 - Softwaregestützte Analyse und Konzeption betrieblicher Energieversorgungsanlagen
T2 - Fortschrittliche Energiewandlung und -anwendung : Schwerpunkt: dezentrale Energiesysteme ; Tagung Bochum, 13. und 14. März 2001. - (VDI-Berichte ; 1594)
Y1 - 2001
SN - 3-18-091594-3
SP - 313
EP - 322
PB - VDI-Verl.
CY - Düsseldorf
ER -
TY - CHAP
A1 - Knoche, K. F.
A1 - Kruska, Martin
A1 - Weber, P.
A1 - Kuperjans, Isabel
ED - Schulz, Werner F.
T1 - Energiemanagement
T2 - Lexikon Nachhaltiges Wirtschaften. - (Lehr- und Handbücher zur ökologischen Unternehmensführung und Umweltökonomie)
Y1 - 2001
SN - 3-486-24523-6
SP - 88
EP - 92
PB - Oldenbourg
CY - München [u.a.]
ER -
TY - CHAP
A1 - Kern, Alexander
A1 - Meppelink, Jan
T1 - Neue Möglichkeiten elektrischer Anschlüsse an die Bewehrung und Untersuchung der Wirkung von Blitzströmen in bewehrtem Beton
N2 - Im Rahmen eines modernen Blitzschutzsystems für Stahlbeton-Bauten bietet es sich an, die Betonbewehrung zu benutzen: - Sie kann die Funktionen der Ableitungseinrichtungen und des Blitzschutz- Potentialausgleichs bei einem klassischen Gebäude-Blitzschutz übernehmen [1]; - Sie kann, ggf. bei entsprechender Ergänzung, als ein geschlossener Käfig ausgebildet werden und damit eine deutliche Reduzierung der Belastung elektrischer / elektronischer Systeme durch blitzinduzierte elektromagnetische Felder erbringen (LEMP-Schutz [2]). Die Nutzung der Bewehrung ist dabei grundsätzlich gleichermaßen bei Neubauten wie auch bei Ertüchtigungen möglich und sinnvoll. So stellt die Nutzung der Bewehrung beispielsweise im Bereich von Großkraftwerken eine wesentliche Ertüchtigungsmaßnahme für den Blitzschutz elektrischer und elektronischer Einrichtungen dar: - Einerseits wird der Blitzschutz-Potentialausgleich durch den Anschluss metallener Einrichtungen wie Elektronik-Schränke, Kabeltrag-Konstruktionen, Rohrleitungen, etc. an die Bewehrung deutlich verbessert. - Andererseits kann bei größeren Gebäuden die elektromagnetische Schirmwirkung durch die elektrische Überbrückung von vorhandenen Dehnfugen bei Stahlbetonbauten optimiert werden. Diese Dehnfugen sind teilweise nur unzureichend überbrückt, so dass bei Blitzeinschlag in das betreffende oder ein benachbartes Gebäude an Kabelstrecken, die über die Dehnfuge hinwegführen, rel. hohe Spannungen induziert werden können [2, 3]. Die sich um das gesamte Gebäude herumziehende oder zwischen zwei Gebäuden befindliche Dehnfuge muss deshalb im Abstand von maximal einigen Metern überbrückt werden. Im Falle von Blitzschutz-Ertüchtigungen in vorhandenen Gebäuden wird bisher an jeder geplanten Anschlussstelle die Bewehrung großflächig (∅ wenige 10 cm) freigelegt, dort ein elektrischer Anschluss zu dem Bewehrungsstab hergestellt, z.B. mittels eines Erdungsfestpunkts, und dann die Betonoberfläche wieder geschlossen. Je nach prognostizierter Strombelastung wird teilweise versucht, den über den Anschluss fließenden Strom bereits auf mehrere Bewehrungsstäbe zu verteilen. Dazu sind entweder die kreuzenden Stäbe zu verschweißen oder es sind direkt Anschlüsse an zwei Bewehrungsstäbe herzustellen. All dieses bedeutet einen hohen Aufwand bei der Freilegung der Bewehrung und auch wieder bei der Schließung der entstandenen Betonlöcher. Es soll deshalb hier untersucht werden, ob es beispielsweise zum Zwecke des Blitzschutz-Potentialausgleichs und auch zur Überbrückung von Dehnfugen ausreichend ist, den Anschluss an die Bewehrung nach einfachen Verfahren nur jeweils an einen Bewehrungsstab herzustellen. Damit würde der finanzielle und administrative Aufwand an Betonarbeiten deutlich reduziert. Die hier dargestellten Verfahren sind dabei insbesondere für den Einsatz bei Blitzschutz-Ertüchtigungen in bestehenden Gebäuden vorgesehen. Abschließend sollen deshalb die Möglichkeiten zur Prüfung korrekter Anschlüsse, die Grenzen der Verfahren sowie auch die Grenzen der Anwendbarkeit bei Neuanlagen diskutiert werden.
KW - Blitzschutz
KW - Stahlbetonkonstruktion
KW - Lightning Protection
KW - reinforced concrete
Y1 - 2001
ER -
TY - CHAP
A1 - Kern, Alexander
A1 - Neskakis, Apostolos
A1 - Müller, Klaus-Peter
T1 - Blitzschutzkonzept für eine netz-autarke Hybridanlage am Beispiel der Anlage VATALI auf Kreta
N2 - Netz-autarke Anlagen bestehen üblicherweise aus einer oder mehreren Photovoltaik- (PV-) Anlagen, ggf. auch Solarthermie- (ST-) Anlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet) und werden vor allem in Gegenden mit sehr schlechter öffentlicher Energieversorgung eingesetzt, d.h. insbesondere in rel. dünn bewohnten Gebieten und in Entwicklungsländern. Der Blitzschutz von netz-autarken Hybridanlagen ist ein bislang noch vergleichsweise unzureichend bearbeitetes Fachgebiet. Für große Windenergie-Anlagen (WEA) wurde in den letzten Jahren eine Zahl von FuE-Projekten durchgeführt, zum Großteil finanziert durch die öffentliche Hand, zum kleineren Teil auch durch die Industrie, d.h. die WEAHersteller. Dabei wurden bestehende Defizite im Design der WEA festgestellt und Maßnahmen vorgeschlagen, die vor den mechanischen Zerstörungen insbesondere des Rotors und vor den Störungen und Zerstörungen an den elektrischen / elektronischen Systemen der WEA weitgehend Schutz bieten [1, 2, 3]. Der Stand-der- Normung ist im Entwurf DIN VDE 0127 Teil 24 „Blitzschutz für Windenergieanlagen“ (dt. Übersetzung des internationalen Drafts IEC 61400-24 „Wind turbine generator systems; Part 24: Lightning Protection“) dokumentiert [4]. Die Maßnahmen sind allerdings insbesondere für größere WEA vorgesehen; im Falle kleinerer WEA lassen sie sich nur bedingt umsetzen. Trotzdem sind auch kleinere WEA rel. stark blitzeinschlaggefährdet, wenn sie auf einer Bergkuppe o.ä. platziert werden. Für solche kleinere WEA, wie sie bei Hybridanlagen üblicherweise Verwendung finden, müssen die Blitzschutzmaßnahmen aus der DIN VDE 0127 Teil 24 angepasst werden. Für PV- und ST-Anlagen ist eine entsprechende Blitzschutz-Norm noch nicht in Sicht. Hier ist vor allem der Schutz gegen direkte Blitzeinschläge in die Anlage bzw. die Gebäude noch nicht ausreichend beachtet. Blitzfangeinrichtungen sind oft nicht vorgesehen. In aller Regel hat man dabei bisher eine Ausführungsform des Blitzschutzes realisiert, die primär einen Ferneinschlag berücksichtigt und die dabei entstehenden induzierten, rel. energieschwachen Überspannungen durch schwächere Schutzelemente wie Rückstromdioden, Bypassdioden und zum Teil thermisch überwachte Varistoren begrenzt [5, 6, 7]. Diese Schutzelemente können allerdings bei Naheinschlägen bzw. Direkteinschlägen überlastet und damit zerstört werden. Darüber hinaus können Nahoder Direkteinschläge auch zur Schwächung der elektrischen Festigkeit der PVModulisolierung führen. Die Folge davon sind lokale extreme Wärmeentwicklungen, die sogar ein Schmelzen von Glas (sekundärer Langzeiteffekt) hervorrufen könnten. Bei einem Blitzeinschlag in die netz-autarke Hybridanlage VATALI auf Kreta im Jahre 2000 wurden sowohl einige mechanische wie auch elektrische Komponenten der Anlage zerstört bzw. zum Teil schwer beschädigt. Die Anlage VATALI besaß zum Zeitpunkt des Blitzeinschlags keinen wirksamen Blitzschutz. Der Gesamtschaden der Hardware belief sich auf ca. 60.000,- EURO. Die exponierte Stellung der Anlage auf einer Bergspitze stellte und stellt nach wie vor ein enormes Blitzeinschlag-Risiko dar, so dass auch zukünftig mit Blitzeinwirkungen gerechnet werden muss. Die Anlage wurde inspiziert, blitzschutz-technische Erfordernisse definiert und daraus Ertüchtigungsmaßnahmen abgeleitet, die mit überschaubarem Aufwand realisierbar sind.
KW - Blitzschutz
KW - Hybridanlage
KW - Regenerative Energieanlagen
KW - Lightning protection
KW - renewable energy
KW - hybrid system
Y1 - 2001
ER -
TY - CHAP
A1 - Kern, Alexander
A1 - Krichel, Frank
A1 - Müller, Klaus-Peter
T1 - Lightning protection design of a renewable energy hybrid-system without power mains connection
N2 - In the year 2000 a direct lightning strike to the hybridsystem without power mains connection VATALI on the Greek island Crete results in the destruction and damage of some mechanical and electrical components. The hybrid-system VATALI was not lightning protected at that time. The hardware damage costs are approx. 60,000 €. The exposed site of the hybrid-system on top of a mountain was and still is the reason for a high risk of lightning strikes. Also in the future further lightning strikes have to be taken into consideration. In the paper a fundamental lightning protection design concept for renewable energy hybrid-systems without power mains connection and protection measures against direct strikes and overvoltages are shown in detail. The design concept was realized exemplarily for the hybrid-system VATALI. The hardware costs for the protection measures were about 15,000 €. About 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection. Future extensions, new installations, or modifications have to be included into the lightning protection design concept of the hybrid-system.
KW - Blitzschutz
KW - Erneuerbare Energien
KW - Hybridsystem
KW - Lightning protection
KW - Renewable energy
KW - hybrid-system
Y1 - 2001
ER -
TY - CHAP
A1 - Dielmann, Klaus-Peter
T1 - Umsetzung Strom-/Gasmarkt nach der Liberalisierung
N2 - Neues Energierecht Strom Neues Energierecht Gas Emissionshandel in Europa - ein interessanter Markt?
KW - Energierecht
KW - Elektrizität
KW - Gas
KW - Emissionshandel
Y1 - 2001
ER -
TY - JOUR
A1 - Chudoba, Rostislav
A1 - Kuhlmann, Wolfram
A1 - Butenweg, Christoph
T1 - Ein technisches Informationssystem zur Entwicklung von Textilbeton
JF - Bauinformatik-Journal : bi-Journal; Zeitschrift für Architekten und Ingenieure
Y1 - 2001
SN - 1436-9060
VL - Bd. 4
IS - H. 6
SP - 15
EP - 20
ER -
TY - CHAP
A1 - Chudoba, Rostislav
A1 - Kuhlmann, Wolfram
A1 - Butenweg, Christoph
T1 - Ein internetbasiertes technisches Informationssystem zur Koordination und Präsentation des Sonderforschungsbereichs 532
T2 - Forum Bauinformatik 2001 - Junge Wissenschaftler Forschen / Richard Romberg .̤ (Hrsg.) (Fortschrittberichte VDI : Reihe 4, Bauingenieurwesen ; Nr. 169)
Y1 - 2001
SN - 3-18-316904-5
SP - 94
EP - 101
PB - VDI-Verlag
CY - Düsseldorf
ER -
TY - JOUR
A1 - Kern, Alexander
A1 - Heidler, Fridolin
A1 - Zischank, Wolfgang J.
A1 - Frentzel, Ralf
T1 - Lightning current distribution and coupling to control cables in power plants or large industrial facilites
Y1 - 2002
N1 - International Conference on Grounding and Earthing <2002, Rio de Janeiro>
ER -
TY - JOUR
A1 - Kern, Alexander
A1 - Landers, E.-U.
T1 - Die neuen Blitzschutz-Vornormen der Reihe VDE-V 0185:2002
Y1 - 2002
ER -
TY - JOUR
A1 - Dielmann, Klaus-Peter
T1 - Kraft-Wärme-Kälte-Kopplung mit Mikrogasturbinen : Abschlussbericht ; [01.09.2000 - 31.01.2002]
Y1 - 2002
N1 - Förderkennzeichen BMBF 17 057 00
PB - Fachhochsch. Aachen, Abt. Jülich, FB 7, NOWUM-Energy
CY - Jülich
ER -
TY - JOUR
A1 - Faber, Christian
A1 - Fritzsche, Ulrich
A1 - Schwarzer, Klemens
T1 - Vergleich der Ergebnisse des quasidynamischen und stationären Kollektortests nach En 12975-2 / Fritzsche, Ulrich ; Faber, Christian ; Schwarzer, Klemens
JF - Zwölftes Symposium Thermische Solarenergie : 24. bis 26. April 2002 / [wiss. Gesamtleitung: Volker Wittwer. Veranst.: OTTI-Energie-Kolleg. Mitveranst.: Arbeitsgemeinschaft Kommunaler Versorgungsunternehmen zur Sparsamen Ernergie- und Wasserverwendung (ASEW), Köln ...]
Y1 - 2002
SN - 3-934681-20-4
N1 - Symposium Thermische Solarenergie <12, 2002, Kloster Banz> ; Energie-Kolleg
SP - 135
EP - 139
PB - OTTI-Energie-Kolleg
CY - Regensburg
ER -
TY - JOUR
A1 - Fritzsche, Ulrich
A1 - Faber, Christian
A1 - Schwarzer, Klemens
T1 - Vergleich der Ergebnisse des quasidynamischen und stationären Kollektortests nach En 12975-2
JF - Zwölftes Symposium Thermische Solarenergie : 24. bis 26. April 2002 / [wiss. Gesamtleitung: Volker Wittwer. Veranst.: OTTI-Energie-Kolleg. Mitveranst.: Arbeitsgemeinschaft Kommunaler Versorgungsunternehmen zur Sparsamen Ernergie- und Wasserverwendung (ASEW), Köln ...]
Y1 - 2002
SN - 3-934681-20-4
N1 - Symposium Thermische Solarenergie <12, 2002, Kloster Banz> ; Energie-Kolleg
SP - 135
EP - 139
PB - OTTI-Energie-Kolleg
CY - Regensburg
ER -
TY - JOUR
A1 - Helsper, Christoph
T1 - Partikelmesstechnik
JF - Reinraumtechnik , Hrsg.: Gail, Lothar
Y1 - 2002
SN - 3-540-66885-3
SP - 57
EP - 82
PB - Springer
CY - Berlin [u.a.]
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Stock, J.
A1 - Indlekofer, K. M.
T1 - Perspectives of resonant tunneling diodes
JF - Recent research developments in materials science & engineering/ 1,2
Y1 - 2002
SN - 81-7895-057-X
N1 - Nebent.: Materials science & engineering
SP - 527
EP - 556
PB - Transworld Research Network
CY - Trivandrum, India
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Indlekofer, K.M.
A1 - Lüth, H.
T1 - Density-matrix description of a quantum dot system with variable lateral confinement in the single-electron tunneling regime. Indlekofer, K.M.; Förster, A.; Lüth, H.
JF - Physica B: Condensed Matter. 314 (2002), H. 1-4
Y1 - 2002
SN - 0921-4526
SP - 499
EP - 502
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Belyaev, A. E.
A1 - Vitusevich, S.A.
A1 - Eaves, L.
T1 - Photoresponse spectra in p-i-n diodes containing quantum dots. Belyaev, A.E.; Vitusevich, S.A.; Eaves, L.; Main, P.C.; Henini, M.; Förster, A.; Reetz, W.; Danylyuk, S.V.
JF - Nanotechnology. 13 (2002), H. 1
Y1 - 2002
SP - 94
EP - 96
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Kicin, S
A1 - Cambel, V.
A1 - Kuliffayova, M.
T1 - Fabrication of GaAs symmetric pyramidal mesas prepared by wet-chemical etching using AlAs interlayer. Kicin, S.; Cambel, V.; Kuliffayova, M.; Gregusova, D.; Kovacova, E.; Novak, J.; Kostic, I.; Forster, A.
JF - Journal of Applied Physics. 91 (2002), H. 2
Y1 - 2002
SN - 1089-7550
SP - 878
EP - 880
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Cambel, V.
A1 - Kicin, S.
A1 - Kuliffayová, M.
T1 - Preparation of patterned GaAs structures for MEMS and MOEMS. Cambel, V.; Kicin, S.; Kuliffayová, M.; Kovácová, E.; Novák, J.; Kostic, I.; Förster, A.
JF - Materials Science and Engineering: C. 19 (2002), H. 2
Y1 - 2002
SN - 0928-4931
SP - 161
EP - 165
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Malindretos, Jörg
A1 - Indlekofer, Klaus Michael
A1 - Lepsa, Mihail Ion
T1 - Homogeneity analysis of ion-implanted resonant tunnelling diodes for applications in digital logic circuits. Malindretos, Jörg; Förster, Arno; Indlekofer, Klaus Michael; Lepsa, Mihail Ion; Hardtdegen, Hilde; Schmidt, Roland; Luth, Hans
JF - Superlattices and Microstructures. 31 (2002), H. 6
Y1 - 2002
SN - 0749-6036
SP - 315
EP - 325
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Darmo, J.
A1 - Schafer, F.
A1 - Kordos, P.
T1 - Thermal resistance of the semiconductor structures for a photomixing device. Darmo, J.; Schafer, F.; Forster, A.; Kordos, P.; Gusten, R
JF - Conference proceedings : Smolenice Castle, Slovakia, October 14 - 16, 2002 / [organizers: Microelectronics Department, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Bratislava]. Ed. by Juraj Breza
Y1 - 2002
SN - 0-7803-7276-X
N1 - International Conference on Advanced Semiconductor Devices and Microsystems ; (4, 2002, Smolenice). ASDAM '02 ; (4 : ; 2002.10.14-16 : ; Smolenice)
SP - 87
EP - 90
PB - IEEE Operations Center
CY - Piscataway, NJ
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Mikulics, M.
A1 - Siebe, F.
A1 - Fox, A.
T1 - Generation of 460 GHz radiation by photomixing in low-temperature-grown MBE GaAs. Mikulics, M.; Siebe, F.; Fox, A.; Marso, M.; Forster, A.; Stuer, H.; Schafer, F.; Gusten, R.; Kordos, P.
JF - Conference proceedings : Smolenice Castle, Slovakia, October 14 - 16, 2002 / [organizers: Microelectronics Department, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Bratislava]. Ed. by Juraj Breza
Y1 - 2002
SN - 0-7803-7276-X
N1 - International Conference on Advanced Semiconductor Devices and Microsystems ; (4, 2002, Smolenice). ASDAM '02 ; (4 : ; 2002.10.14-16 : ; Smolenice)
SP - 129
EP - 132
PB - IEEE Operations Center
CY - Piscataway, NJ
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Vitusevich, S. A.
A1 - Belyaev, A. E.
A1 - Sheka, D. I.
T1 - Resonant tunneling effect in a periodically modulated electrical field. Vitusevich, S.A.; Forster, A.; Belyaev, A.E.; Sheka, D.I.; Luth, H.; Klein, N.; Danylyuk, S.V.; Konakova, R.
JF - Proceedings of the Tenth International Conference on Modulated Semiconductor Structures : held at the Johannes Kepler University, Linz, Austria, July 23 - 27, 2001 / MSS 10. Guest ed.: Günther Bauer ...
Y1 - 2002
N1 - International Conference on Modulated Semiconductor Structures ; (10, 2001, Linz). Zugleich: Physica E: Low-dimensional Systems and Nanostructures. 13(2002)2-4. ISSN 1386-9477
SP - 811
EP - 813
PB - Elsevier
CY - Amsterdam [u.a.]
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Adam, R.
A1 - Mikulics, M.
A1 - Schelten, J.
T1 - Fabrication and subpicosecond optical response of low-temperature-grown GaAs freestanding photoconductive devices. Adam, R.; Mikulics, M.; Forster, A.; Schelten, J.; Siegel, M.; Kordos, P.; Zheng, X.; Wu, S.; Sobolewski, R.
JF - Applied Physics Letters. 81 (2002), H. 18
Y1 - 2002
SN - 1077-3118
SP - 3485
EP - 3487
ER -
TY - BOOK
A1 - Thielemann, Frank
A1 - Bachem, Claus
T1 - Überlegungen zur Evaluation von Technologieförderprogrammen
Y1 - 2002
SN - 3-933628-42-3
N1 - Institut für Wirtschaftswissenschaften der Technischen Universität Braunschweig ; 02/02
PB - nst. für Wirtschaftswiss.
CY - Braunschweig
ER -
TY - JOUR
A1 - Hoffschmidt, Bernhard
A1 - Krödel, Matthias
A1 - Geigl, Florian
T1 - Die Kraft der Sonne / Matthias Krödel ; Florian Geigl ; Bernhard Hoffschmidt
JF - Nachrichten : Magazin des Deutschen Zentrums für Luft- und Raumfahrt / DLR (2002)
Y1 - 2002
SN - 0937-0420
SP - 18
EP - 19
ER -
TY - JOUR
A1 - Hoffschmidt, Bernhard
A1 - Fend, Thomas
A1 - Jorgensen, Gary
T1 - Comparative assessment of solar concentrator materials / Thomas Fend ; Bernhard Hoffschmidt ; Gary Jorgensen ...
JF - Renewable energy for local communities of Europe : (toward Rio+10) ; proceedings / EuroSun 2002, the 4th ISES Europe Solar Congress ; Bologna (Italy), 23 - 26 June 2002 / ISES Italia
Y1 - 2002
SN - 88-900893-0-X
N1 - Eurosun <4, 2002, Bologna> ; International Solar Energy Society
SP - paper_125.pdf
CY - Bologna
ER -
TY - BOOK
A1 - Goldbach, Daniel
T1 - Steuerung und Regelung der aktiven Anhängerkupplung eines Farhzeuggespanns
Y1 - 2002
N1 - Fulda, Fachhochsch., Dipl.-Arbeit, 2002
ER -
TY - CHAP
A1 - Augenstein, Eckardt
A1 - Kuperjans, Isabel
A1 - Lucas, K.
ED - Tsatsaronis,, Georgios
T1 - EUSEBIA - Decision-Support-System for Technical, Economical and Ecological Design and Evaluation of Industrial Energy Systems
T2 - ECOS 2002 : proceedings of the 15th International Conference on Efficiency, Costs, Optimization, Simulation and Environmental Impact of Energy Systems, Berlin, Germany July 3 - 5, 2002. - Vol. 1
Y1 - 2002
SN - 3-00-009533-0
SP - 446
EP - 453
PB - Techn. Univ., Inst. for Energy Engineering
CY - Berlin
ER -
TY - CHAP
A1 - Kern, Alexander
T1 - Risikomanagement : Abschätzung des Schadensrisikos für bauliche Anlagen - Die neue Vornorm DIN V VDE V 0185 Teil 2 : 2002
N2 - Alle Unternehmen sind vielfältigen Risiken ausgesetzt, die Finanz- und Betriebsbereiche einschließlich Dienstleistungen betreffen können. Die Firmen müssen üblicherweise Risiken eingehen, um im Wettbewerb bestehen zu können. Entscheidend ist, dass man sich über die Risiken bewusst ist, diese einschätzen und kontrollieren kann. Falsche Einschätzungen, Versäumnisse und Fehlentscheidungen können empfindliche finanzielle Schäden bis hin zum Totalverlust nach sich ziehen. Ein effektives Risikomanagement ist heute als wichtiger Sicherheitsfaktor anzusehen und sollte zur strategischen Unternehmensführung gehören. Ein vorausschauendes Risikomanagement beinhaltet, Risiken für das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise über Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht geeignet sind (z.B. Erhaltung der Lieferfähigkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht verändern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verfügbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem übersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gefährdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschläge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Norm DIN V 0185-2 VDE V 0185 Teil 2 gefunden. Die hier vorgegebene Risikoanalyse gewährleistet, dass ein für alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei möglichst geringem Aufwand den notwendigen Schutz gewährleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 detailliert beschrieben.
KW - Blitzschutz
KW - Risikomanagement
KW - Risikoabschätzung
KW - Versicherung
KW - Lightning protection
KW - Risk management
KW - Risk assessment ; Insurance
Y1 - 2002
ER -
TY - CHAP
A1 - Darveniza, M.
A1 - Flisowski, Z.
A1 - Kern, Alexander
A1 - Landers, E.-U.
A1 - LoPiparo, G.
A1 - Mazzetti, C.
A1 - Rousseau, A.
A1 - Sherlock, J.
T1 - Application problems of the probabilistic approach to the assessment of risk for structures and services
N2 - The paper deals with the development of the probabilistic approach to the assessment of risk due to lightning. Sources of damage, types of damage and types of loss are defined and, accordingly, the procedure for risk analysis and the way of assessment of different risk components is proposed. The way to evaluate the influence of different protection measures (lightning protection system; shielding of structure, cables and equipment; routing of internal wiring; surge protective device) in reducing such probabilities is considered. The paper has been prepared within the framework of the activity of IEC TC81-WG9/CLC TC81-WG4 directed to prepare the draft IEC 62305-2 Risk Management, in cooperation with the Secretary of IEC/CLC TC81.
KW - Blitzschutz
KW - Risikoabwägung
KW - Lightning protection system
KW - risk assessment
KW - protection measures
Y1 - 2002
ER -
TY - CHAP
A1 - Kern, Alexander
A1 - Krichel, Frank
T1 - Considerations about the lightning protection system of mains independent renewable energy hybrid-systems - practical experiences
N2 - In the paper a lightning protection design concept for renewable energy hybrid-systems without power mains connection is described. Based on a risk analysis protection measures against direct strikes and overvoltages are shown in an overview. The design concept is realized exemplarily for the hybrid-system VATALI on the Greek island Crete. VATALI, not lightning protected at that time, was a victim of a lightning strike in the year 2000 causing destructions and damages of some mechanical and electrical components with costs of approx. 60.000 €. The hardware costs for the protection measures were about 15.000 €: about 50% of the costs are due to protection measures against direct strikes, 50% are due to overvoltage protection.
KW - Blitzschutz
KW - Erneuerbare Energien
KW - Hybridsystem
KW - Photovoltaikanlage
KW - Windenergieanlage
KW - Lightning protection
KW - renewable energy
KW - hybrid system
KW - photovoltaic system
KW - wind turbine
Y1 - 2002
ER -
TY - CHAP
A1 - Zischank, Wolfgang J.
A1 - Heidler, Fridolin
A1 - Kern, Alexander
A1 - Metwally, I. A.
A1 - Wiesinger, J.
A1 - Seevers, M.
T1 - Laboratory simulation of direct lightning strokes to a modelled building - measurement of magnetic fields and induced voltages
N2 - In IEC 61312-2 equations for the assessment of the magnetic fields inside structures due to a direct lightning strike are given. These equations are based on computer simulations for shields consisting of a single-layer steel grid of a given mesh width. Real constructions, however, contain at least two layers of reinforcement steel grids. The objective of this study was to experimentally determine the additional shielding effectiveness of a second reinforcement layer compared to a single-layer grid. To this end, simulated structures were set up in the high current laboratory. The structures consisted of cubic cages of 2 m side length with one or with two reinforcement grids, respectively. The structures were exposed to direct lightning currents representing the variety of anticipated lightning current waveforms. The magnetic fields and their derivatives at several positions inside the structure as well as the voltage between “floor” and “roof” in the center were determined for different current injection points. From these data the improvement of the shielding caused by a second reinforcement layer is derived.
KW - Direkter Blitzschlag
KW - Elektromagnetischer Schutzschild
KW - Magnetische Felder
KW - Induzierte Spannungen
KW - Stahlbetonkonstruktion
KW - Lightning
KW - electromagnetic shielding
KW - magnetic field
KW - reinforced concrete
KW - induced voltage
Y1 - 2002
ER -
TY - CHAP
A1 - Dielmann, Klaus-Peter
A1 - Peters, Bernhard
T1 - Micro Turbine Using Different Gases and Liquid Fuels
N2 - Micro turbine using different gases and liquid fuels
KW - Gasturbine
KW - Mikrogasturbine
KW - Micro turbine
Y1 - 2002
ER -
TY - CHAP
A1 - Dielmann, Klaus-Peter
T1 - Darstellung des Erneuerbaren Energiegesetzes (EEG) und dessen Auswirkungen
N2 - Erneuerbares Energien-Gesetz: Anwendungsbereich, Abnahme- und Vergütungspflicht, Vergütungssätze, Netzkosten, Ausgleichsregelungen Auswirkungen des EEG: Photovoltaik, Windkraft, Biomasse, Wasserkraft, Klär-, Deponie- und Grubengas, Geothermie Zusammenfassung und Ausblick
KW - Energierecht
KW - Erneuerbares Energiengesetz
Y1 - 2002
ER -
TY - JOUR
A1 - Walter, G.
A1 - Borchert, Jörg
T1 - Der Einsatz von Realoptionen in der Elektrizitätswirtschaft
JF - M & A Review
Y1 - 2002
SN - 1616-0878
IS - 4
SP - 198
ER -
TY - CHAP
A1 - El-Deib, Khaled
A1 - Chudoba, Rostislav
A1 - Butenweg, Christoph
A1 - Meskouris, Konstantin
A1 - Könke, Carsten
A1 - Bettzieche, Volker
T1 - Safety assessment of rockfill and masonry dams
T2 - Structural dynamics - EURODYN 2002 : proceedings of the 4th [i.e. 5th] International Conference on Structural Dynamics, Munich, Germany, 2 - 5 September 2002 / ed. by H. Grundmann ... Vol. 1
Y1 - 2002
SN - 90-5809-510-X
SP - 237
EP - 242
PB - Balkema
CY - Lisse
ER -
TY - CHAP
A1 - Karvanek, Eva
A1 - Butenweg, Christoph
A1 - Ebenau, Carsten
T1 - Bautechnische Prüfung und Bauüberwachung der Arena „Auf Schalke“
T2 - Berichte der Fachtagung Baustatik - Baupraxis 8 am 21. und 22. März 2002 in Braunschweig / Hrsg. Dieter Dinkler
Y1 - 2002
SN - 3-926031-95-6
SP - 237
EP - 245
PB - TU Braunschweig, Institut für Statik
CY - Braunschweig
ER -
TY - CHAP
A1 - Holler, S.
A1 - Butenweg, Christoph
A1 - Noh, S.-Y.
A1 - Meskouris, Konstantin
T1 - Numerical simulation of textile-reinforced concrete structures
T2 - Proceedings of the Sixth International Conference on Computational Structures Technology : [Prague, Czech Republic, 4 - 6 September 2002] / ed. by B. H. V. Topping and Z. Bittnar. (Civil-Comp Press books on computational engineering)
Y1 - 2002
SN - 0-948749-83-0
SP - 287
EP - 288
PB - Civil-Comp Press
CY - Stirling
ER -
TY - CHAP
A1 - Chudoba, Rostislav
A1 - Butenweg, Christoph
A1 - Kuhlmann, Wolfram
T1 - Technical information system for collaborative material research
T2 - Sixth International Conference on Computational Structures Technology : [Prague, Czech Republic, 4 - 6 September 2002]
Y1 - 2002
SP - 1
EP - 11
ER -
TY - CHAP
A1 - Wagner, R.
A1 - Noh, S.-Y.
A1 - Butenweg, Christoph
A1 - Meskouris, Konstantin
T1 - Seismic excited granular material silos
T2 - Structural dynamics - EURODYN 2002 : proceedings of the 4th [i.e. 5th] International Conference on Structural Dynamics, Munich, Germany, 2 - 5 September 2002 / ed. by H. Grundmann ...
Y1 - 2002
SN - 90-5809-511-8
SP - 253
EP - 258
PB - Balkema
CY - Lisse
ER -
TY - JOUR
A1 - Helsper, Christoph
T1 - Messverfahren zur Charakterisierung der Abscheidung luftgetragener Partikel in Filtern
JF - Schutzmaßnahmen vor mikrobiellen Belastungen des Innenraumes / VII. Lübecker Fachtagung für Umwelthygiene. [Hrsg.:] Reinhard Keller ...
Y1 - 2003
N1 - Lübecker Fachtagung für Umwelthygiene <7, 2003, Lübeck>
SP - 35
EP - 61
PB - Inst. f. Medizinische Mikrobiologie u. Hygiene d. Med. Univ.
CY - Lübeck
ER -
TY - JOUR
A1 - Förster, Arnold
T1 - Layer Deposition I
JF - Fundamentals of nanoelectronics / Stefan Blügel ... (ed.). - (Lecture manuscripts of the ... Spring School of the Department of Solid State Research ; 34). - (Schriften des Forschungszentrums Jülich : Materie und Material ; 14 ; 34)
Y1 - 2003
SN - 3-89336-319-X
SP - C2.1
EP - C2.13
PB - Forschungszentrum, Zentralbibliothek
CY - Jülich
ER -
TY - JOUR
A1 - Förster, Arnold
A1 - Kiesslich, G.
A1 - Wacker, A.
A1 - Scholl, E.
T1 - Nonlinear charging effect of quantum dots in a p-i-n diode. Kiesslich, G.; Wacker, A.; Scholl, E.; Vitusevich, S.A.; Belyaev, A.E.; Danylyuk, S.V.; Forster, A.; Klein, N.; Henini, M.
JF - Physical Review B. 68 (2003)
Y1 - 2003
SN - 1550-235X
N1 - 125331 (6 Seiten)
ER -
TY - JOUR
A1 - Schwarzer, Klemens
A1 - Silva, Maria Eugênia Vieira da
T1 - Solar cooking system with or without heat storage for families and institutions
JF - Solar energy. 75 (2003), H. 1
Y1 - 2003
SN - 0038-092x
N1 - 2. ISSN: 0375-9865
SP - 34
EP - 41
ER -
TY - BOOK
A1 - Schwarzer, Klemens
A1 - Müller, C.
T1 - Entwicklung und Optimierung einer Gebäudeheizung für den Einsatz in Hochgebirgsregionen mit hoher solarer Einstrahlung : Abschlussbericht
Y1 - 2003
PB - Solar-Institut Juelich, Fachhochschule Aachen
CY - Jülich
ER -
TY - JOUR
A1 - Dielmann, Klaus-Peter
A1 - Cudina, Boris
A1 - Mehlkopf, Marcus
T1 - Einfluss der Brennstoffdaten auf die CO2-Inventarisierung : Handel mit Emissionsrechten
JF - Euroheat and power : Kraft-Wärme-Kopplung, Nah-/Fernwärme, Contracting
Y1 - 2003
SN - 0949-166X
VL - 32
IS - 9
SP - 22
EP - 25
ER -
TY - JOUR
A1 - Hoffschmidt, Bernhard
A1 - Fend, Thomas
A1 - Jorgensen, Gary
A1 - Küster, Harald
T1 - Comparative assessment of solar concentrator materials / Fend, Thomas ; Hoffschmidt, Bernhard ; Jorgensen, Gary ; Küster, Harald ; Krüger, Dirk ; Pitz-Paal, Robert ; Riebrock, Peter ; Riffelmann, Klaus-Jürgen
JF - Solar energy. 74 (2003), H. 2
Y1 - 2003
SN - 0038-092X
SP - 149
EP - 155
ER -
TY - JOUR
A1 - Hoffschmidt, Bernhard
A1 - Téllez, Félix M.
A1 - Valverde, Antonio
A1 - Fernandez, Valerio
A1 - Fernandez, Jesus
T1 - Performance evaluation of the 200-kWth HiTRec-II open volumetric air receiver
JF - Journal of solar energy engineering
Y1 - 2003
VL - Vol. 125
IS - Iss. 1
SP - 87
EP - 94
ER -
TY - JOUR
A1 - Maezawa, Koichi
A1 - Förster, Arnold
T1 - Quantum transport devices based on resonant tunneling
JF - Nanoelectronics and information technology : advanced electronic materials and novel devices / Rainer Waser (ed.).
Y1 - 2003
SN - 3-527-40363-9
SP - 407
EP - 424
PB - Wiley-VCH
CY - Weinheim
ER -
TY - CHAP
A1 - Kern, Alexander
T1 - Abschätzung des Blitzschadensrisikos für bauliche Anlagen - Die neue Bestimmung DIN V VDE V 0185 Teil 2 : 2002 - Allgemeines, Abschätzungsverfahren, Berechnungsbeispiele
N2 - Ein vorausschauendes Risikomanagement beinhaltet, Risiken für das Unternehmen zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent, welche Risiken sinnvollerweise über Versicherungen abgedeckt werden sollten. Beim Versicherungsmanagement ist jedoch zu bedenken, dass zur Erreichung bestimmter Ziele Versicherungen nicht immer geeignet sind (z.B. Erhaltung der Lieferfähigkeit). Eintrittswahrscheinlichkeiten bestimmter Risiken lassen sich durch Versicherungen nicht verändern. Bei Unternehmen, die mit umfangreichen elektronischen Einrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nicht-Verfügbarkeit der elektronischen Einrichtungen und damit der Produktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardware-Schaden an der betroffenen Anlage oft bei weitem übersteigt. Im Blitzschutz gewinnt innovatives Denken in Schadensrisiken langsam an Bedeutung. Risikoanalysen haben die Objektivierung und Quantifizierung der Gefährdung von baulichen Anlagen und ihrer Inhalte durch direkte und indirekte Blitzeinschläge zum Ziel. Seinen Niederschlag hat dieses neue Denken in der neuen deutschen Vornorm DIN V 0185-2 VDE V 0185 Teil 2 [1] gefunden. Die hier vorgegebene Risikoanalyse gewährleistet, dass ein für alle Beteiligten nachvollziehbares Blitzschutz-Konzept erstellt werden kann, das technisch und wirtschaftlich optimiert ist, d.h. bei möglichst geringem Aufwand den notwendigen Schutz gewährleisten kann. Die sich aus der Risikoanalyse ergebenden Schutzmaßnahmen sind dann in den weiteren Normenteilen der neuen Reihe VDE V 0185 [2, 3] detailliert beschrieben.
KW - Blitzschutz
KW - Risikomanagement
KW - Risikoabschätzung
KW - Lightning protection
KW - Risk management
KW - Risk assessment
Y1 - 2003
ER -
TY - JOUR
A1 - Kern, Alexander
T1 - Risikomanagement für den Blitzschutz - Abschätzung des Blitzschadensrisikos nach der neuen Vornorm VDE V 0185 Teil 2 : 2002
N2 - Ein vorausschauendes Risikomanagement beinhaltet, Risiken zu kalkulieren. Es liefert Entscheidungsgrundlagen, um diese Risiken zu begrenzen und es macht transparent,welche Risiken sinnvoll über Versicherungen abgedeckt werden sollten. Bei Unternehmen, die mit umfangreichen elektronischenEinrichtungen produzieren oder Dienstleistungen erbringen (und das sind heutzutage wohl die meisten), muss auch das Risiko durch Blitzeinwirkungen besondere Berücksichtigung finden. Dabei ist zu beachten, dass der Schaden aufgrund der Nichtverfügbarkeit der elektronischen Einrichtungen und damit derProduktion bzw. der Dienstleistung und ggf. der Verlust von Daten den Hardwareschaden an der betroffenen Anlage oft bei weitem übersteigt.
KW - Blitzschutz
KW - Risikomanagement
KW - Risikoabschätzung
KW - Lightning protection
KW - Risk management
KW - Risk assessment
Y1 - 2003
ER -
TY - CHAP
A1 - Krichel, Frank
A1 - Kern, Alexander
A1 - Krämer, Heinz-Josef
A1 - Wettingfeld, Jürgen
A1 - Reetz, Josef
A1 - Kienlein, Manfred
T1 - Blitzschutzmaßnahmen für Photovoltaik- und kleine Windenergieanlagen – Einige Beispiele
T1 - Lightning Protection for photovoltaic and small wind energy power plants
N2 - Ein von der Arbeitsgemeinschaft (AG) Solar NRW und diversen Industriepartnern gefördertes und an der Fachhochschule Aachen, Abt. Jülich durchgeführtes Forschungsprojekt „Blitzschutz für netz-autarke Hybridanlagen“ machte es möglich, sich mit dem Blitzschutz speziell solcher Anlagen näher zu beschäftigen. Vermehrt bekannt gewordene Schadensfälle an nicht netz-gekoppelten Hybridanlagen waren der Auslöser, den Schutz zu überdenken. Definiertes Ziel war es, für netz-autarke energietechnische Anlagen ein Konzept zum Schutz vor Blitzeinwirkungen zu erstellen. Diese Anlagen bestehen üblicherweise aus einer oder mehreren Photovoltaikanlagen, ggf. auch Solarthermieanlagen und einem oder mehreren kleineren Windgeneratoren (sie werden deshalb auch als Hybridanlagen bezeichnet). Zur Erhöhung der Versorgungssicherheit kann noch ein Dieselaggregat dazukommen. Hybridanlagen werden vor allem in Gebieten mit sehr schlechter öffentlicher Energieversorgung eingesetzt, d.h. insbesondere in relativ dünn bewohnten Gebieten und in Entwicklungsländern. Dem Blitzschutz von Hybridanlagen kommt dabei eine steigende Bedeutung zu. Besonderes Augenmerk in dem genannten Forschungsprojekt sollte dabei auf die technisch/wirtschaftliche Ausgewogenheit des Schutzes gelegt werden: • die Schutzmaßnahmen sollen nur in solchen Fällen eingesetzt werden, wo dies als Ergebnis von Risikoanalysen sinnvoll erscheint; • für typische netz-autarke Hybridanlagen sollen die Schutzmaßnahmen ohne deutliche Verteuerung realisierbar sein (es soll also kein absoluter Schutz realisiert werden; ggf. soll lediglich der auftretende Schaden soweit möglich minimiert werden). Dazu wurde in einem ersten Schritt zunächst eine Aufnahme des Iststandes einiger typischer netz-autarker Hybridanlagen und deren einzelnen Komponenten durchgeführt. Aufgrund dessen wurde eine umfassende Risikoanalyse zur Blitzbedrohung dieser Anlagen auf der Basis von VDE V 0185 Teil 2:2002-11 [1] erstellt. Die Ergebnisse mündeten in ein technisch/wirtschaftlich ausgewogenes Konzept für den Anlagen- Blitzschutz (d.h. insbesondere dem Schutz vor direkten Blitzeinschlägen und deren unmittelbaren Auswirkungen) nach VDE V 0185 Teil 3:2002-11 [2] und für den Elektronik-Blitzschutz (d.h. für den Schutz vor Überspannungen durch direkte, insbesondere aber auch indirekte Blitzeinschläge) nach VDE V 0185 Teil 4:2002-11 [3]. Aufgrund der gesammelten Ergebnisse konnten dabei allgemeine Empfehlungen für den Äußeren und Inneren Blitzschutz von regenerativen Energieerzeugungssystemen erstellt werden. Diese sollen in Schulungen einmünden, die für Hersteller und Betreiber von Hybridanlagen angeboten werden. Durch die Anwendung wird der Schutz der Anlagen vor Blitzeinwirkung und elektromagnetischen Störungen verbessert, was sich in einer reduzierten Ausfallwahrscheinlichkeit bzw. erhöhten Verfügbarkeit wiederspiegelt. An einigen ausgewählten Anlagen werden mit Hilfe der im Projekt involvierten Industriepartner die Schutzmaßnahmen realisiert. Hierbei entstanden den Eigentümern bzw. Betreibern der Anlagen keine Kosten. In diesem Beitrag werden beispielhaft drei Anlagenprojekte detailliert gezeigt. Es handelt sich dabei um eine Schweinezuchtfarm in Magallón (Spanien, Zaragozza), das bioklimatische Haus (Kreta, Heraklion) und die Tegernseer- Hütte (Deutschland, Lenggries).
KW - Blitzschutz
KW - Photovoltaikanlagen
KW - Windenergieanlagen
KW - Lightning protection
KW - photovoltaic system
KW - wind turbine
Y1 - 2003
ER -
TY - CHAP
A1 - Kern, Alexander
T1 - Risikomanagement nach DIN V 0185-2 VDE V 0185 Teil 2: 2002-11 - Einige Beispiele und erste Erfahrungen
T1 - Risk management based on DIN V 0185-2 VDE V 0185 part 2: 2002-11 - Some examples and first experiences
N2 - Die neue Vornorm VDE V 0185 Teil 2 „Risikomanagement: Abschätzung des Schadensrisikos für bauliche Anlagen“ [1] ist seit November 2002 gültig. Sie ermöglicht nicht nur die Ermittlung der Schutzklasse eines Blitzschutzsystems, sondern auch die Untersuchung zur Notwendigkeit anderer Schutzmaßnahmen gegen Blitzeinwirkungen (Überspannungsschutzgeräte in Unterverteilern und/oder an Endgeräten, Schirmung des Gebäudes und/oder interner Räume, Potentialsteuerung, Brandmelde- und Feuerlöscheinrichtungen, etc.) nach objektiven Kriterien und damit in einer für alle Beteiligten grundsätzlich nachvollziehbaren Art und Weise. Dass eine solche Analyse rel. komplex sein muss und der intensiven Beschäftigung bedarf, ist deshalb nicht verwunderlich. Die Komplexität des Verfahrens sollte allerdings nicht dazu führen, die Vornorm als Ganzes abzulehnen. Die Vornorm beruht auf dem Stand der Diskussion im internationalen Normengremium IEC TC81 WG9 Ende des Jahres 2000. Integriert wurden einige nationale Besonderheiten, die aus Sicht des zuständigen Normenkomitees DKE K251 erforderlich erschienen. In Deutschland konnten und können nun erste breite Erfahrungen in der Anwendung dieser Risikoanalyse gesammelt werden; in anderen Ländern ist dies noch nicht möglich. Diese Erfahrungen können dann, nach Diskussion im nationalen Rahmen, in die internationale Normenarbeit eingebracht werden. Im folgenden Beitrag sollen einige, seit Erscheinen der Vornorm oft wiederkehrende Fragen dargestellt und Lösungsvorschläge vorgestellt werden. Dabei wird auch auf die Tendenzen im internationalen Normengremium IEC TC81 WG9 eingegangen, d.h. auf den aktuellen Entwurf zur IEC 62305-2 [3]. Die Lösungsvorschläge werden begründet, sind allerdings weitestgehend subjektive Meinung des Autors. Für übliche bauliche Anlagen ist die Anwendung der Vornorm rel. einfach möglich. Auch für spezielle Fälle können die darin festgelegten Verfahren herangezogen werden; allerdings sind dann einige weiterführende Überlegungen notwendig, die der Planer von Blitzschutzsystemen durchführen muss. Anhand zweier Beispiele soll die Anwendung der VDE V 0185 Teil 2 auf solche speziellen Fälle dargestellt werden.
KW - Blitzschutz
KW - Risikomanagement
KW - Lightning protection
KW - risk management
Y1 - 2003
ER -
TY - CHAP
A1 - Kern, Alexander
A1 - Krämer, Heinz-Josef
T1 - Blitzschutzkonzept für eine bauliche Anlage mit Stahlkonstruktion und metallenen Wänden
N2 - Bauliche Anlagen mit Stahlkonstruktionen (bzw. auch Stahlbetonskelett- Konstruktionen) und metallenen Wänden sind bereits in sehr großer Zahl errichtet. Dazu gehören kleinere bis größere Lagerhallen ebenso wie Einkaufszentren. Sie zeichnen sich durch große Flexibilität, einfache Planung, kurze Bauzeit und rel. geringe Kosten aus. Auch in der nahen Zukunft ist deshalb mit Planung und Errichtung weiterer solcher baulicher Anlagen zu rechnen. Abhängig von der Nutzung der Hallen sind auch mehr oder weniger umfangreiche elektrische und elektronische Systeme vorhanden, die wichtige Funktionen sicherstellen müssen. Der Blitzschutz für diese baulichen Anlagen sollte sich also nicht nur im „klassischen“ Gebäude-Blitzschutz nach DIN V 0185-3 VDE V 0185 Teil 3 [1] erschöpfen; ein Ergänzung hin zu einem sinnvollen Grundschutz der elektrischen und elektronischen Systeme nach DIN V 0185-4 VDE V 0185 Teil 4 [2] ist anzuraten. Im folgenden Beitrag wird ein Konzept vorgestellt, mit dem ein hochwertiger Blitzschutz sowohl der baulichen Anlage und der darin befindlichen Personen, als auch der elektrischen und elektronischen Systeme verwirklicht werden kann. Insbesondere bei großflächigen Hallen stellen sich dabei besondere Anforderungen. Das Konzept und die zugehörigen blitzschutz-technischen Maßnahmen können drei Hauptbereichen zugeordnet werden: - Äußerer Blitzschutz; - Innerer Blitzschutz; - weitergehende besondere Maßnahmen. Das Konzept sowie die Maßnahmen werden allgemein beschrieben und teilweise anhand einer ausgeführten Anlage mit Fotos beispielhaft dokumentiert.
KW - Blitzschutz
KW - Stahlbetonkonstruktion
KW - Lightning protection
KW - reinforced concrete
Y1 - 2003
ER -
TY - JOUR
A1 - Kern, Alexander
A1 - Krichel, Frank
T1 - Überlegungen zum Blitzschutzkonzept für regenerative Energieanlagen
N2 - Dem Blitzschutz von Anlagen der regenerativen Energien kommt in Zukunft eine steigende Bedeutung zu. Dabei ist es notwendig zu berücksichtigen, dass die Schutzmaßnahmen technisch/wirtschaftlich ausgewogen sind. Erbauer, Besitzer oder Benutzer von netzautarken Hybridanlagen haben zu entscheiden, ob die Anlage einen Schutz braucht oder nicht. Um diese Entscheidung zu fällen, ist eine Risikoanalyse als erster Schritt sinnvoll. Diese muss dabei die für die Hybridanlage relevanten Schadenarten und spezifischen Parameter, Werte und Randbedingungen mit einbeziehen. Dazu ist die Hilfe eines Blitzschutzexperten sehr hilfreich.
KW - Alternative Energiequelle
KW - Energietechnische Anlage
KW - Blitzschutz
KW - Blitzschutz
KW - Regenerative Energieanlagen
KW - Lightning protection
KW - renewable energy
Y1 - 2003
ER -
TY - CHAP
A1 - Dielmann, Klaus-Peter
A1 - Cudina, Boris
T1 - Emissionsrechtehandel in Europa - ein neues Instrument für den Umweltschutz
N2 - Funktionsprinzip Emissionsrechtehandel, Betroffene Anlagen und Branchen, Erstverteilung der Emissionsrechte, Bereits erbrachte Emissionsreduktionen (early actions), Ausstieg von betroffenen Unternehmen (opt-out), Teilnahme von nicht betroffenen Unternehmen, Einsatz von Biobrennstoffen, Erfassung und Dokumentation der Emissionen
KW - Umweltzertifikathandel
KW - Emissionsrechtehandel
Y1 - 2003
ER -
TY - CHAP
A1 - Dielmann, Klaus-Peter
A1 - Velden, Alwin van der
T1 - Virtuelle Kraftwerke - Stand der Technik
N2 - Ausgangslage, Funktionsprinzip des virtuellen Kraftwerkes, Energiemanagementsysteme (EMS), Einsatzgebiete, Anlagesysteme eines VKW's, Einsatzbereich der verschiedenen dezentralen Energieanlagen, Vorteile des virtuellen Kraftwerkes, Auswirkungen auf das elektrische Netz, Wirtschaftliche Aspekte, Beispielprojekte
KW - Virtuelle Kraftwerke
Y1 - 2003
ER -
TY - THES
A1 - Borchert, Jörg
T1 - Analyse von Determinanten der Großhandelspreise für Elektrizität anhand einer Systemstudie des deutschen Marktes
Y1 - 2003
N1 - Berlin, Techn. Univ., Diss., 2003
ER -