TY - JOUR A1 - Heinzel, Alexander A1 - Schäfer, Ralf A1 - Müller, Hans-Wilhelm A1 - Schieffer, Andre A1 - Ingenhag, Ariane A1 - Northoff, Georg A1 - Franz, Matthias A1 - Hautzel, Hubertus T1 - Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals JF - Neuroreport N2 - High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli. Y1 - 2010 U6 - https://doi.org/10.1097/WNR.0b013e32833f38e0 SN - 1473-558X VL - 21 IS - 15 SP - 998 EP - 1002 PB - Lippincott Williams & Wilkins CY - London ER - TY - JOUR A1 - Nomdedeu, Mar Monsonis A1 - Willen, Christine A1 - Schieffer, Andre A1 - Arndt, Hartmut T1 - Temperature-dependent ranges of coexistence in a model of a two-prey-one-predator microbial food web JF - Marine Biology N2 - The objective of our study was to analyze the effects of temperature on the population dynamics of a three-species food web consisting of two prey bacteria (Pedobacter sp. and Acinetobacter johnsonii) and a protozoan predator (Tetrahymena pyriformis) as model organisms. We assessed the effects of temperature on the growth rates of all three species with the objective of developing a model with four differential equations based on the experimental data. The following hypotheses were tested at a theoretical level: Firstly, temperature changes can affect the dynamic behavior of a system by temperature-dependent parameters and interactions and secondly, food web response to temperature cannot be derived from the single species temperature response. The main outcome of the study is that temperature changes affect the parameter range where coexistence is possible within all three species. This has significant consequences on our ideas regarding the evaluation of effects of global warming. Y1 - 2012 U6 - https://doi.org/10.1007/s00227-012-1966-x SN - 1432-1793 VL - 159 IS - 11 SP - 2423 EP - 2430 PB - Springer CY - Berlin ER - TY - JOUR A1 - Mosset, J.-B. A1 - Devroede, O. A1 - Krieguer, M. A1 - Rey, M. A1 - Vieira, J.-M. A1 - Jung, J. H. A1 - Kuntner, C. A1 - Streun, M. A1 - Ziemons, Karl A1 - Auffray, E. A1 - Sempere-Roldan, P. A1 - Lecoq, P. A1 - Bruyndonckx, P. A1 - Loude, J.-F. A1 - Tavernier, S. A1 - Morcel, C. T1 - Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator JF - IEEE Transactions on Nuclear Science N2 - This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 1 SP - 25 EP - 29 ER - TY - JOUR A1 - Streun, M. A1 - Beer, S. A1 - Hombach, T. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - PlanTIS: A positron emission tomograph for imaging 11C transport in plants JF - 2007 IEEE Nuclear Science Symposium Conference Record, Vol. 6 N2 - Plant growth and transport processes are highly dynamic. They are characterized by plant-internal control processes and by strong interactions with the spatially and temporally varying environment. Analysis of structure- function relations of growth and transport in plants will strongly benefit from the development of non-invasive techniques. PlanTIS (Plant Tomographic Imaging System) is designed for non-destructive 3D-imaging of positron emitting radiotracers. It will permit functional analysis of the dynamics of carbon distribution in plants including bulky organs. It will be applicable for screening transport properties of plants to evaluate e.g. temperature adaptation of genetically modified plants. PlanTIS is a PET scanner dedicated to monitor the dynamics of the 11C distribution within a plant while or after assimilation of 11CO2. Front end electronics and data acquisition architecture of the scanner are based on the ClearPETTM system [1]. Four detector modules form one of two opposing detector blocks. Optionally, a hardware coincidence detection between the blocks can be applied. In general the scan duration is rather long (~ 1 hour) compared to the decay time of 11C (20 min). As a result the count rates can vary over a wide range and accurate dead time correction is necessary. Y1 - 2008 SN - 1082-3654 SP - 4110 EP - 4112 ER - TY - JOUR A1 - Ziemons, Karl A1 - Bruyndonckx, P. A1 - Perez, J. M. A1 - Pietrzyk, U. A1 - Rato, P. A1 - Tavernier, S. T1 - Beyond ClearPET: Next Aims JF - 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro Symposium Proceedings ISBI 2008 N2 - The CRYSTAL CLEAR collaboration, in short CCC, is a consortium of 12 academic institutions, mainly from Europe, joining efforts in the area of developing instrumentation for nuclear medicine and medical imaging. In the framework of the CCC a high performance small animal PET system, called ClearPET, was developed by using new technologies in electronics and crystals in a phoswich arrangement combining two types of lutetium- based scintillator materials: LSO:Ce and LuYAP:Ce. Our next aim will be the development of hybrid image systems. Hybrid MR-PET imaging has many unique advantages for brain research. This has sparked a new research line within CCC for the development of novel MR-PET compatible technologies. MRI is not as sensitive as PET but PET has poorer spatial resolution than MRI. Two major advantages of PET are sensitivity and its ability to acquire metabolic information. To assess these innovations, the development of a 9.4T hybrid animal MR-PET scanner is proposed based on an existing 9.4T MR scanner that will be adapted to enable simultaneous acquisition of MR and PET data using cutting- edge technology for both MR and PET. Y1 - 2008 SN - 978-1-4244-2003-2 SP - 1421 EP - 1424 ER - TY - JOUR A1 - Jahnke, Siegfried A1 - Menzel, Marion I. A1 - Dusschoten, Dagmar van A1 - Roeb, Gerhard W. A1 - Bühler, Jonas A1 - Minwuyelet, Senay A1 - Blümler, Peter A1 - Temperton, Vicky M. A1 - Hombach, Thomas A1 - Streun, Matthias A1 - Beer, Simone A1 - Khodaverdi, Maryam A1 - Ziemons, Karl A1 - Coenen, Heinz H. A1 - Schurr, Ulrich T1 - Combined MRI–PET dissects dynamic changes in plant structures and functions JF - The Plant Journal N2 - Unravelling the factors determining the allocation of carbon to various plant organs is one of the great challenges of modern plant biology. Studying allocation under close to natural conditions requires non-invasive methods, which are now becoming available for measuring plants on a par with those developed for humans. By combining magnetic resonance imaging (MRI) and positron emission tomography (PET), we investigated three contrasting root/shoot systems growing in sand or soil, with respect to their structures, transport routes and the translocation dynamics of recently fixed photoassimilates labelled with the short-lived radioactive carbon isotope 11C. Storage organs of sugar beet (Beta vulgaris) and radish plants (Raphanus sativus) were assessed using MRI, providing images of the internal structures of the organs with high spatial resolution, and while species-specific transport sectoralities, properties of assimilate allocation and unloading characteristics were measured using PET. Growth and carbon allocation within complex root systems were monitored in maize plants (Zea mays), and the results may be used to identify factors affecting root growth in natural substrates or in competition with roots of other plants. MRI–PET co-registration opens the door for non-invasive analysis of plant structures and transport processes that may change in response to genomic, developmental or environmental challenges. It is our aim to make the methods applicable for quantitative analyses of plant traits in phenotyping as well as in understanding the dynamics of key processes that are essential to plant performance. Y1 - 2009 SN - 1365-313X VL - 59 IS - 4 SP - 634 EP - 644 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Wedrowski, M. A1 - Bruyndonckx, P. A1 - Tavernier, S. A1 - Zhi, L. A1 - Dang, J. A1 - Mendes, P. R. A1 - Perez, J. M. A1 - Ziemons, Karl T1 - Robustness of neural networks algorithm for gamma detection in monolithic block detector, positron emission tomography JF - 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The monolithic scintillator block approach for gamma detection in the Positron Emission Tomography (PET) avoids estimating Depth of Interaction (DOI), reduces dead zones in detector and diminishes costs of detector production. Neural Networks (NN) are very efficient to determine the entrance point of a gamma incident on a scintillator block. This paper presents results on the robustness of the spatial resolution as a function of the random fraction in the data, temperature and HV fluctuations. This is important when implementing the method in a real scanner. Measurements were done with two Hamamatsu S8550 APD arrays, glued on a 20 × 20 × 10 mm3 monolithic LSO crystal block. Y1 - 2009 SN - 1082-3654 SP - 2625 EP - 2628 ER - TY - JOUR A1 - Streun, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - A compact PET detector readout using charge-to-time conversion JF - 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics. Y1 - 2009 SN - 1082-3654 SP - 1868 EP - 1870 PB - IEEE CY - New York ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse recording by free-running sampling JF - IEEE Transactions on Nuclear Science N2 - Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free-running ADCs at a sampling rate of 40 MHz. A four-channel acquisition board has been developed which is equipped with four 12-bit ADCs connected to one field programmable gate array (FPGA). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware trigger can be omitted. The method of free-running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. This information is crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows very high count rates to be dealt with. Since this method is to be employed in positron emission tomography (PET), the position of an event is also important. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO scintillators coupled to the PS-PMT are presented here Y1 - 2001 SN - 0018-9499 VL - 48 IS - 3 SP - 524 EP - 526 ER - TY - JOUR A1 - Heinrich, U. A1 - Blum, A. A1 - Bussmann, N. A1 - Engels, R. A1 - Kemmerling, G. A1 - Weber, S. A1 - Ziemons, Karl T1 - Statistical studies on the light output and energy resolution of small LSO single crystals with different surface treatments combined with various reflector materials JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The optimization of light output and energy resolution of scintillators is of special interest for the development of high resolution and high sensitivity PET. The aim of this work is to obtain statistically reliable results concerning optimal surface treatment of scintillation crystals and the selection of reflector material. For this purpose, raw, mechanically polished and etched LSO crystals (size 2×2×10 mm3) were combined with various reflector materials (Teflon tape, Teflon matrix, BaSO4) and exposed to a 22Na source. In order to ensure the statistical reliability of the results, groups of 10 LSO crystals each were measured for all combinations of surface treatment and reflector material. Using no reflector material the light output increased up to 551±35% by mechanical polishing the surface compared to 100±5% for raw crystals. Etching the surface increased the light output to 441±29%. The untreated crystals had an energy resolution of 24.6±4.0%. By mechanical polishing the surface it was possible to achieve an energy resolution of 13.2±0.8%, by etching of 14.8±0.7%. In combination with BaSO4 as reflector material the maximum increase of light output has been established to 932±57% for mechanically polished and 895±61% for etched crystals. The combination with BaSO4 also caused the best improvement of the energy resolution up to 11.6±0.2% for mechanically polished and 12.2±0.3% for etched crystals. Relating to the light output there was no significant statistical difference between the two surface treatments in combination with BaSO4. In contrast to this, the statistical results of the energy resolution have shown the combination of mechanical polishing and BaSO4 as the optimum. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 60 EP - 66 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system with free running ADCs JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - A small PET system has been built up with two multichannel photomultipliers, which are attached to a matrix of 64 single LSO crystals each. The signal from each multiplier is being sampled continuously by a 12 bit ADC at a sampling frequency of 40 MHz. In case of a scintillation pulse a subsequent FPGA sends the corresponding set of samples together with the channel information and a time mark to the host computer. The data transfer is performed with a rate of 20 MB/s. On the host all necessary information is extracted from the data. The pulse energy is determined, coincident events are detected and multiple hits within one matrix can be identified. In order to achieve a narrow time window the pulse starting time is refined further than the resolution of the time mark (=25 ns) would allow. This is possible by interpolating between the pulse samples. First data obtained from this system will be presented. The system is part of developments for a much larger system and has been created to study the feasibility and performance of the technique and the hardware architecture. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 18 EP - 21 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Coincidence detection by digital processing of free-running sampled pulses JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns. Y1 - 2002 SN - 0168-9002 VL - 487 IS - 3 SP - 530 EP - 534 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Pauly, F. A1 - Schroder, G. A1 - Ziemons, Karl A1 - Sievering, R. A1 - Halling, H. T1 - Preliminary studies of a micro-CT for a combined small animal PET/CT scanner JF - 2001 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - We are developing an X-ray computed tomography (CT) system which will be combined with a high resolution animal PET system. This permits acquisition of both molecular and anatomical images in a single machine. In particular the CT will also be utilized for the quantification of the animal PET data by providing accurate data for attenuation correction. A first prototype has been built using a commercially available plane silicon diode detector. A cone-beam reconstruction provides the images using the Feldkamp algorithm. First measurements with this system have been performed on a mouse. It could be shown that the CT setup fulfils all demands for a high quality image of the skeleton of the mouse. It is also suited for soft tissue measurements. To improve contrast and resolution and to acquire the X-ray energy further development of the system, especially the use of semiconductor detectors and iterative reconstruction algorithms are planned. Y1 - 2002 SN - 1082-3654 SP - 1605 EP - 1606 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system based on data processing of free-running sampled pulses JF - 2001 IEEE Nuclear Science Symposium Conference Record, Vol. 2 N2 - Within the developments for the Crystal Clear small animal PET project (CLEARPET) a dual head PET system has been established. The basic principle is the early digitization of the detector pulses by free running ADCs. The determination of the γ-energy and also the coincidence detection is performed by data processing of the sampled pulses on the host computer. Therefore a time mark is attached to each pulse identifying the current cycle of the 40 MHz sampling clock. In order to refine the time resolution the pulse starting time is interpolated from the samples of the pulse rise. The detector heads consist of multichannel PMTs with a single LSO scintillator crystal coupled to each channel. For each PMT only one ADC is required. The position of an event is obtained separately from trigger signals generated for each single channel. An FPGA is utilized for pulse buffering, generation of the time mark and for the data transfer to the host via a fast I/O-interface. Y1 - 2002 SN - 1082-3654 SP - 693 EP - 694 ER - TY - JOUR A1 - Heinrichs, U. A1 - Pietrzyk, U. A1 - Ziemons, Karl T1 - Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 JF - IEEE Transactions on Nuclear Science N2 - Within the Crystal Clear Collaboration (CCC), four centers are developing second generation high performance small animal positron emission tomography (PET) scanners for different kinds of animals and medical applications. The first prototypes are photomultiplier tube (PMT)-based systems including depth of interaction (DOI) detection by using a phoswich layer of lutetium oxyorthosilicate (LSO) and lutetium yttrium aluminum perovskite (LuYAP). The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in fields of view (FOVs) caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN, Geneva, Switzerland) was used. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 5 SP - 1428 EP - 1432 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - 2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 1082-3654 SP - 1636 EP - 1639 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - IEEE Transactions on Nuclear Science N2 - A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 3 SP - 344 EP - 347 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chaziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different microCT scanner configurations by GEANT4 simulations JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - This study has been performed to design the combination of the new ClearPET TM (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal Positron Emission Tomography (PET) system, with a microComputed Tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2004 SN - 1082-3654 SP - 2989 EP - 2993 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. T1 - The ClearPET TM LSO/LuYAP phoswich scanner: a high performance small animal PET system JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes. Y1 - 2004 SN - 1082-3654 SP - 1728 EP - 1732 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Brökel, M. A1 - Fuss, L. A1 - Larue, H. A1 - Parl, C. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - The ClearPET data acquisition JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - Within the Crystal Clear Collaboration a modular system for a small animal PET scanner (ClearPET™) has been developed. The modularity allows the assembly of scanners of different sizes and characteristics in order to fit the specific needs of the individual member institutions. Now a first demonstrator is being completed in Julich. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to multi-channel photomultipliers (PMTs). A free-running ADC digitizes the signal from the PMT and the complete scintillation pulses are sampled by an FPGA and sent with 20 MB/S to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. An advantage of that is that the coincidence window and the dimensions of the field of view can be adjusted easily. The ClearPET™ demonstrator is equipped with 10240 crystals on 80 PMTs. This paper presents an overview of the data acquisition system. Y1 - 2004 SN - 1082-3654 SP - 3097 EP - 3100 ER - TY - JOUR A1 - Christ, D. A1 - Hollendung, A. A1 - Larue, H. A1 - Parl, C. A1 - Streun, M. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. T1 - Homogenization of the MultiChannel PM gain by inserting light attenuating masks JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - MultiChannel Photomultipliers (PM), like the R7600-00-M64 or R5900-00-M64 from Hamamatsu, are often chosen as photodetectors in high-resolution positron emission tomography (PET). A major problem of this PM is the nonuniform channel gain. In order to solve this problem, light attenuating masks were created. The aim of the masks is a homogenization of the output of all 64 channels using different hole sizes at the channel positions. The hole area, which is individually defined for the different channels, is inversely proportional to the channel gain. The measurements by inserting light attenuating masks improved a homogenization to a ratio of 1:1.2. Y1 - 2004 SN - 1082-3654 SP - 2382 EP - 2385 ER - TY - JOUR A1 - Ziemons, Karl A1 - Heinrichs, U. A1 - Streun, M. A1 - Pietrzyk, U. T1 - Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. Y1 - 2004 SN - 1082-3654 SP - 3053 EP - 3056 ER - TY - JOUR A1 - Auffray, E. A1 - Bruyndonckx, P. A1 - Devroede, O. A1 - Fedorov, A. A1 - Ziemons, Karl T1 - The ClearPET project JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view. Y1 - 2004 SN - 0168-9002 N1 - Proceedings of the 2nd International Conference on Imaging Technologies in Biomedical Sciences VL - 527 IS - 1-2 SP - 171 EP - 174 ER - TY - JOUR A1 - Streun, M. A1 - Christ, D. A1 - Hellendung, A. A1 - Larue, H. A1 - Ziemons, Karl A1 - Halling, H. T1 - Effects of crosstalk and gain nonuniformity using multichannel PMTs in the Clearpet® scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 402 EP - 405 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. A1 - Bruyndonckx, P. T1 - The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view. Preliminary data shows a correct identification of the crystal layer about (98±1)%. Typically the energy resolution is (23.3±0.5)% for the luyap layer and (15.4±0.4)% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 307 EP - 311 ER - TY - JOUR A1 - Beer, S. A1 - Streun, M. A1 - Hombach, T. A1 - Buehler, J. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants JF - Physics in Medicine and Biology N2 - Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements. Y1 - 2010 U6 - https://doi.org/10.1088/0031-9155/55/3/006 SN - 1361-6560 VL - 55 IS - 3 SP - 635 EP - 646 PB - IOP CY - Bristol ER - TY - JOUR A1 - Herzog, Hans A1 - Pietrzyk, Uwe A1 - Shah, N. Jon A1 - Ziemons, Karl T1 - The current state, challenges and perspectives of MR-PET JF - Neuroimage N2 - Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization. Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop. Y1 - 2010 U6 - https://doi.org/10.1016/j.neuroimage.2009.10.036 SN - 1053-8119 VL - 49 IS - 3 SP - 2072 EP - 2082 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Parl, C. A1 - Larue, H. A1 - Streun, M. A1 - Ziemons, Karl T1 - Double-side-readout technique for SiPM-matrices JF - 2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit. Y1 - 2011 SN - 1095-7863 SP - 1486 EP - 1487 PB - IEEE CY - New York ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Suso, Henri-Pierre A1 - Rysstad, Gunnar A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes JF - Physica status solidi (a) N2 - A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests. KW - calorimetric gas sensor;hydrogen peroxide;wireless sensor system Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200920 SN - 1862-6319 VL - 210 IS - 5 SP - 877 EP - 883 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chatziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different MicroCT scanner configurations by GEANT4 simulations JF - IEEE Transactions on Nuclear Science N2 - This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2005 SN - 0018-9499 VL - 52 IS - 1 SP - 188 EP - 192 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - The data acquisition system of ClearPET neuro - a small animal PET scanner JF - IEEE Transactions on Nuclear Science N2 - The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 3 SP - 700 EP - 703 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Weber, S. A1 - Streun, M. A1 - Parl, C. A1 - Ziemons, Karl T1 - High resolution imaging with ClearPET™ Neuro - first animal images JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance. Y1 - 2006 SN - 1082-3654 SP - 1641 EP - 1644 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - Timemark correction for the ClearPET™ scanners JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented Y1 - 2006 SN - 1082-3654 SP - 2057 EP - 2060 ER - TY - JOUR A1 - Porschen, W. A1 - Gartzen, J. A1 - Gewehr, K. A1 - Mühlensiepen, H. A1 - Weber, Hans-Joachim A1 - [u.a.], T1 - In vivo assay of the radiation sensitivity of hypoxic tumour cells : influence of γ-rays, cyclotron neutrons, misonidazole, hyperthermia and mixed modalities JF - The British journal of cancer / Supplement N2 - Tumour cell death can be evaluated in the living mouse by externally measuring the rate of loss of tumour-bound DNA tracer. By sequentially labelling the tumour-bearing animals with ¹²⁵IUdR and ¹³¹IUdR 50 h apart, the average tumour cells at the time of the second injection are labelled by ¹²⁵IUdR and the euoxic tumour cells are specifically labelled with ¹³¹IUdR. Tumour treatment at this stage of labelling permits the observation of the reaction of euoxic cells and average tumour cells and finally yields data on hypoxic cells and thus on the oxygen enhancement ratio. This information adds to results from tumour control and growth delay. With this technique effects were analysed of 60-Co γ-rays, cyclotron neutrons (E = 6 MeV), misonidazole (500 mg/kg body wt) and hyperthermia (42°C water-bath), or combinations of these. Misonidazole (15 min before irradiation) altered the oxygen enhancement ratio by a factor of 1·5 for γ-rays and of 1·1 for neutrons; when evaluated from tumour-growth delay and TCD-50 misonidazole gave a dose modifying factor of 1·47 for γ-rays and of 1·2-1·3 for neutrons. Based on percentage tumour regression 100 days after treatment, the enhancement ratio from hyperthermia (after irradiation) was 2·75 for γ-rays (at 10 Gray) and 2·2 for neutrons (at 3·2 Gray). For neutrons combined with misonidazole and hyperthermia the ratio was 2·4. These results demonstrate that effects of neutron irradiation may be modified by electron-affinic substances and/or hyperthermia. Y1 - 1978 SN - 0306-9443 N1 - Section 6: Sensitization and Hypoxic Cytotoxicity: Effects of Hyperthermia and High Let IS - 3 SP - 194 EP - 197 PB - Lewis CY - London ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Ichimura, Hiroki A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel JF - Sensors and actuators. B: Chemical N2 - The chemical imaging sensor is a device to visualize the spatial distribution of chemical species based on the principle of LAPS (light-addressable potentiometric sensor), which is a field-effect chemical sensor based on semiconductor. In this study, the chemical imaging sensor has been applied to investigate the ion profile of laminar flows in a microfluidic channel. The chemical images (pH maps) were collected in a Y-shaped microfluidic channel while injecting HCl and NaCl solutions into two branches. From the chemical images, it was clearly observed that the injected solutions formed laminar flows in the channel. In addition, ion diffusion across the laminar flows was observed, and the diffusion coefficient could be derived by fitting the pH profiles to the Fick's equation. Y1 - 2013 U6 - https://doi.org/10.1016/j.snb.2013.04.057 SN - 1873-3077 (E-Journal); 0925-4005 (Print) N1 - Part of special issue "Selected Papers from the 26th European Conference on Solid-State Transducers" VL - 189 SP - 240 EP - 245 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Trattner, Barbara A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Stütz, Evamaria A1 - Schmitt-Landsiedel, Doris A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment JF - Sensors and actuators. B: Chemical Y1 - 2013 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - Vol. 182 SP - 58 EP - 65 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kramer, Friederike A1 - Halamkova, Lenka A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Katz, Evgeny A1 - Halamek, Jan T1 - Biocatalytic analysis of biomarkers for forensic identification of ethnicity between Caucasian and African American JF - The analyst. August 2013 Y1 - 2013 SN - 1364-5528 (E-Journal); 0003-2654 (Print) VL - Vol. 138 SP - 6251 EP - 6257 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Laack, Walter van T1 - The genetic code should be seen as a positioning code JF - British journal of arts and social sciences. Vol. 14 (2013), No. 1 Y1 - 2013 SN - 2046-9578 SP - 93 EP - 97 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Kayatekin, Muammer B. A1 - Uysal, N. A1 - Resmi, H. T1 - Does antioxidant supplementation alter the effects of acute exercise on erythrocyte aggregation, deformability and endothelium adhesion in untrained rats? Kayatekin, Muammer B.; Uysal N.; Resmi, H.; Bediz, Seref C.; Temiz Artmann, A.; Genç, S.; Tugyan, K. JF - International Journal for Vitamin and Nutrition Research. 75 (2005), H. 4 Y1 - 2005 SN - 0300-9831 SP - 243 EP - 250 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Resmi, Halil A1 - Akhunlar, Hülya A1 - Güner, Gül T1 - In vitro effects of high glucose concentrations on membrane protein sulfhydryl oxidation, G-actin and deformability of human erythrocytes. Resmi, Halil ; Akhunlar, Hülya ; Temiz Artmann, Aysegül ; Güner, Gül JF - Cell biochemistry and function. 23 (2005), H. 3 Y1 - 2005 SN - 0263-6484 SP - 163 EP - 168 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Cavdar, C. A1 - Yenicerioglu, Y. A1 - Caliskan, S. T1 - The effects of intravenous iron treatment on oxidant stress and erythrocyte deformability in haemodialysis patients. Cavdar, C.; Temiz, A.; Yenicerioglu, Y.; Caliskan, S.; Celik, A.; Sifil, A.; Onvural, B.; Camsari, T. JF - Scandinavian Journal of Urology and Nephrology. 37 (2003), H. 1 Y1 - 2003 SN - 0036-5599 SP - 77 EP - 82 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Yalcin, Ozlem A1 - Resmi, Halil A1 - Baskurt, Oguz K. T1 - Can white blood cell activation be one of the major factors that affect hemorheological parameters during and after exercise? JF - Clinical Hemorheology and Microcirculation. 26 (2002), H. 3 Y1 - 2002 SN - 1386-0291 N1 - = The 11th European Symposium on Clinical Hemorheology, Rouen, France, 19-22 September 2000 SP - 189 EP - 193 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, Oguz K. A1 - Pekcetin, C. A1 - Kandemir, F. T1 - Leukocyte activation, oxidant stress and red blood cell properties after acute, exhausting exercise in rats. Temiz, A.; Baskurt, O. K., Pekcetin, C.; Kandemir, F.; Güre, A. JF - Clinical Hemorheology and Microcirculation. 22 (2000), H. 4 Y1 - 2000 SN - 1386-0291 SP - 253 EP - 259 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Yolcuoglu, B. A1 - Onal, M. A. A1 - Sipahi, O. T1 - The effect of skin transplantation on tumour growth in mice. Yolcuoglu, B.; Onal, M. A.; Sipahi, O.; Temiz, A.; Pekcetin, C.; Acikgöz, O.; Kar, H.; Güre A. JF - The American Journal of Surgery. 178 (1999), H. 4 Y1 - 1999 SN - 0002-9610 SP - 329 EP - 330 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Ates, H. A1 - Üretmen, Ö. A1 - Andac, K. T1 - Erythrocyte deformability in high-tension and normal tension glaucoma. Ates, H.; Üretmen, Ö.; Temiz, A.; Andac, K. JF - International Ophthalmology. 22 (1998), H. 1 Y1 - 1998 SN - 0165-5701 SP - 7 EP - 12 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Meiselman, H. J. T1 - Effect of superoxide anions on red blood cell rheologic properties. Baskurt, O. K.; Temiz, A.; Meiselman, H. J. JF - Free Radical Biology and Medicine. 24 (1998), H. 1 Y1 - 1998 SN - 0891-5849 SP - 102 EP - 110 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Meiselman, H. J. T1 - Red blood cell aggregation in experimental sepsis . Baskurt, O. K.; Temiz, A.; Meiselman, H. J. JF - Journal of Laboratory and Clinical Medicine. 130 (1997), H. 2 Y1 - 1997 SN - 0022-2143 SP - 183 EP - 190 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Edremitlioglu, M. T1 - Effect of erythrocyte deformability on myocardial hematocrit gradient. Baskurt, O.K.; Edremitlioglu, M.; Temiz, A. JF - American Journal of Physiology: Heart and Circulatory Physiology. 268 (1995), H. 1 Y1 - 1995 SN - 0363-6135 SP - 260 EP - 264 ER - TY - JOUR A1 - Staat, Manfred T1 - Failure probabilities of the primary circuit pressure boundary of an HTR-Module for process heat generation under accident conditions for different failure modes JF - Nuclear Engineering and Design. 144 (1993), H. 1 Y1 - 1993 SN - 0029-5493 SP - 53 EP - 67 ER - TY - JOUR A1 - Staat, Manfred A1 - Vu, Khoi Duc T1 - Limit loads of circumferentially flawed pipes and cylindrical vessels under internal pressure JF - International Journal of Pressure Vessels and Piping. 83 (2006), H. 3 Y1 - 2006 SN - 0308-0161 SP - 188 EP - 196 ER - TY - JOUR A1 - Staat, Manfred T1 - Reliability of an HTR-module primary circuit pressure boundary Influences, sensitivity, and comparison with a PWR JF - Nuclear Engineering and Design. 158 (1995), H. 2-3 Y1 - 1995 SN - 0029-5493 SP - 333 EP - 340 ER - TY - JOUR A1 - Staat, Manfred T1 - Probabilistic assessment of the fracture mechanics behaviour of an HTR-module primary circuit pressure boundary JF - Nuclear Engineering and Design. 160 (1996), H. 1-2 Y1 - 1996 SN - 0029-5493 SP - 221 EP - 236 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - FEM-computation of load carrying capacity of highly loaded passive components by direct methods. Heitzer, M. ; Staat, M. JF - Nuclear Engineering and Design. 193 (1999), H. 3 Y1 - 1999 SN - 0029-5493 SP - 349 EP - 358 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Edremitlioglu, M. T1 - In vitro effects of in vivo activated leukocytes on red blood cell filterability and lipid peroxidation. Baskurt, O.K.; Edremitlioglu, M.; Temiz, A. JF - Clinical Hemorheology. 14 (1994), H. 4 Y1 - 1994 SP - 591 EP - 596 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Akhisaroglu, M. A1 - Sercan, Z. A1 - Kayatekin, B. M. T1 - Adhesion of Erythrocytes to Endothelial Cells After Acute Exercise: Differences in Red Blood Cells from Juvenile and Adult Rats. Temiz Artmann, A.; Akhisaroglu, M.; Sercan, Z.; Kayatekin, BM.; Yorukoglu, K.; Kirkali, G. JF - Physiological Research (2005) Y1 - 2005 SN - 0862-8408 N1 - pre-press article ER - TY - JOUR A1 - Vu, Duc Khoi A1 - Staat, Manfred A1 - Tran, Ich Thinh T1 - Analysis of pressure equipment by application of the primal-dual theory of shakedown JF - Communications in Numerical Methods in Engineering. 23 (2007), H. 3 Y1 - 2007 SN - 1069-8299 SP - 213 EP - 225 ER - TY - JOUR A1 - Vu, Duc Khoi A1 - Staat, Manfred T1 - Shakedown analysis of structures made of materials with temperature-dependent yield stress JF - International Journal of Solids and Structures. 44 (2007), H. 13 Y1 - 2007 SN - 0020-7683 SP - 4524 EP - 4540 ER - TY - JOUR A1 - Pawelke, Siegfried A1 - Butzer, Paul L. T1 - Semi-groups and resolvent operators JF - Archive for Rational Mechanics and Analysis KW - Resolvent Operator KW - Electromagnetism KW - Complex System KW - Neural Network KW - Nonlinear Dynamics Y1 - 1968 U6 - https://doi.org/10.1007/BF00250941 SN - 0003-9527 VL - 30 IS - 2 SP - 127 EP - 147 PB - Springer CY - Berlin ER - TY - JOUR A1 - Pawelke, Siegfried T1 - Weak smoothness conditions for the uniform convergence of Fourier-Jacobi series JF - Functiones et Approximatio. Commentarii Mathematici. 9 (1980) Y1 - 1980 SN - 0208-6573 N1 - Zentralblatt MATH: http://www.emis.de/MATH-item?0471.42018 SP - 9 EP - 13 ER - TY - JOUR A1 - Turek, Monika A1 - Ketterer, Lothar A1 - Claßen, Melanie A1 - Berndt, Heinz A1 - Elbers, Gereon A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Development and Electrochemical Investigations of an EIS-(Electrolyte-Insulator-Semiconductor) based Biosensor for Cyanide Detection JF - Sensors Y1 - 2007 SN - 1424-8220 VL - 7 IS - 8 SP - 1415 EP - 1426 ER - TY - JOUR A1 - Wagner, Torsten A1 - Molina, Roberto A1 - Yoshinobu, Tatsuo A1 - Kloock, Joachim P. A1 - Biselli, Manfred A1 - Canzoneri, Michele A1 - Schnitzler, Thomas A1 - Schöning, Michael Josef T1 - Handheld multi-channel LAPS device as a transducer platform for possible biological and chemical multi-sensor applications JF - Electrochimica Acta. 53 (2007), H. 2 Y1 - 2007 SN - 0013-4686 SP - 305 EP - 311 ER - TY - JOUR A1 - Pawelke, Siegfried A1 - Schmitt, W. A1 - Meissen, Th. T1 - Aachen 3D finger. 3D digitizer for application in dentistry / Schmitt, W. ; Pawelke, S. ; Meissen, Th. JF - Biomedizinische Technik. 35 (1990), H. 4 Y1 - 1990 SN - 0013-5585 SP - 69 EP - 71 ER - TY - JOUR A1 - Pawelke, Siegfried T1 - Note on Jackson and Bernstein type approximation theorems in the case of approximation by algebraic polynomial in the spaces L and C JF - Studia Scientiarum Mathematicarum Hungarica. 36 (2000), H. 3-4 Y1 - 2000 SN - 0081-6906 SP - 353 EP - 358 ER - TY - JOUR A1 - Sander, Volker A1 - Erwin, Dietmar A1 - Huber, Valentina T1 - High-performance computer management based on Java JF - Future Generation Computer Systems. 15 (1999), H. 3 Y1 - 1999 SN - 0167-739X SP - 425 EP - 432 ER - TY - JOUR A1 - Sander, Volker A1 - Foster, Ian A1 - Roy, Alain A1 - Winkler, Linda T1 - A differentiated services implementation for high-performance TCP flows JF - Computer Networks. 34 (2000), H. 6 Y1 - 2000 SN - 1389-1286 SP - 915 EP - 929 ER - TY - JOUR A1 - Sander, Volker A1 - Czajkowski, K. A1 - Foster, I. A1 - Kesselman, C. T1 - SNAP: A Protocol for Negotiating Service Level Agreements and Coordinating Resource Management in Distributed Systems / Czajkowski, K. ; Foster, I. ; Kesselman, C. ; Sander, V. ; Tuecke, S. JF - Job Scheduling Strategies for Parallel Processing : 8th InternationalWorkshop, JSSPP 2002 Edinburgh, Scotland, UK, July 24, 2002. Revised Papers Y1 - 2002 SN - 3-540-00172-7 N1 - Lecture Notes in Computer Science ; 2537 ; JSSPP <8, 2002, Edinburgh > SP - 153 EP - 183 PB - Springer CY - Berlin ER - TY - JOUR A1 - Sander, Volker A1 - Roy, Alain T1 - GARA: A Uniform Quality of Service Architecture / Roy, Alain ; Sander, Volker JF - Grid resource management : state of the art and future trends / ed. by Jarek Nabrzyski; Jennifer M. Schopf; Jan W̜eglarz Y1 - 2004 SN - 1-4020-7575-8 N1 - International series in operations research & management science ; 64 SP - 377 EP - 394 PB - Kluwer Academic Publ. CY - Boston ER - TY - JOUR A1 - Sander, Volker A1 - Fidler, Markus T1 - A parameter based admission control for differentiated services networks / Fidler, Markus ; Sander, Volker JF - Computer Networks. 44 (2004), H. 4 Y1 - 2004 SN - 1389-1286 SP - 463 EP - 479 ER - TY - JOUR A1 - Sander, Volker A1 - Foster, Ian T. A1 - Fidler, Markus A1 - Roy, Alain T1 - End-to-end quality of service for high-end applications / Foster, Ian T. ; Fidler, Markus ; Roy, Alain ; Sander, Volker ; Winkler, Linda JF - Computer Communications. 27 (2004), H. 14 Y1 - 2004 SN - 0140-3664 SP - 1375 EP - 1388 ER - TY - JOUR A1 - Sander, Volker A1 - Fidler, Markus A1 - Klimala, Wojciech T1 - Traffic shaping in aggregate-based networks: implementation and analysis / Fidler, Markus ; Sander, Volker ; Klimala, Wojciech JF - Computer Communications. 28 (2005), H. 3 Y1 - 2005 SN - 0140-3664 SP - 274 EP - 286 ER - TY - JOUR A1 - Laack, Walter van A1 - Refisch, A. T1 - Neuralgic amyotrophy of the lumbar area. Case Report / Refisch, A. ; Laack, W. van JF - Archives of Orthopaedic and Trauma Surgery. 108 (1989), H. 5 Y1 - 1989 SN - 0936-8051 SP - 329 EP - 332 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kirchner, Patrick A1 - Ng, Yue Ann A1 - Spelthahn, Heiko A1 - Schneider, Andreas A1 - Henkel, Hartmut A1 - Friedrich, Peter A1 - Kolstad, Jens A1 - Berger, Jörg A1 - Keusgen, Michael T1 - Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 787 EP - 792 ER - TY - JOUR A1 - Turek, Monik A1 - Heiden, Wolfgang A1 - Guo, Sharon A1 - Riesen, Alfred A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 817 EP - 823 ER - TY - JOUR A1 - Buniatyan, Vahe V. A1 - Abouzar, Maryam H. A1 - Martirosyan, Norayr W. A1 - Schubert, Jürgen A1 - Gevorgian, Spartak A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - pH-sensitive properties of barium strontium titanate (BST) thin films prepared by pulsed laser deposition technique JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 824 EP - 830 ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Siqueira, José R. Jr. A1 - Oliveira, Osvaldo N. Jr. A1 - Moritz, Werner A1 - Schöning, Michael Josef T1 - Capacitive electrolyte-insulator-semiconductor structures functionalised with a polyelectrolyte/enzyme multilayer: New strategy for enhanced field-effect biosensing JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 884 EP - 890 ER - TY - JOUR A1 - Reisert, Steffen A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schäfer, Daniel A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Schöning, Michael Josef T1 - Development of a handheld sensor system for the online measurement of hydrogen peroxide in aseptic filling systems JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 913 EP - 918 ER - TY - JOUR A1 - Beging, Stefan A1 - Mlynek, Daniela A1 - Hataihimakul, Sudkanung A1 - Poghossian, Arshak A1 - Baldsiefen, Gerhard A1 - Busch, Heinz A1 - Laube, Norbert A1 - Kleinen, Lisa A1 - Schöning, Michael Josef T1 - Field-effect calcium sensor for the determination of the risk of urinary stone formation JF - Sensors and Actuators B: Chemical. 144 (2010), H. 2 Y1 - 2010 N1 - 22nd International Conference on Eurosensors - Dresden, Germany, 7-10 September 2008 ; Eurosensors ; (22, 2008, Dresden) SP - 374 EP - 379 ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Sugawara, Yuri A1 - Kanoh, Shin´ichiro A1 - Yoshinobu, Tatsuo A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Image correction method for the chemical imaging sensor JF - Sensors and Actuators B: Chemical. 144 (2010), H. 2 Y1 - 2010 N1 - 22nd International Conference on Eurosensors - Dresden, Germany, 7-10 September 2008 ; Eurosensors ; (22, 2008, Dresden) SP - 344 EP - 348 ER - TY - JOUR A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Wenmackers, Sylvia A1 - Janssens, Stoffel D. A1 - Haenen, Ken A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Capacitive field-effect (bio-)chemical sensors based on nanocrystalline diamond films JF - Diamond Electronics and Bioelectronics — Fundamentals to Applications III, edited by P. Bergonzo, [u.a.] Y1 - 2010 N1 - MRS Proceedings Volume 1203 paper 1203-J17-31 ; Mater. Res. Soc. Sympos. Proc. Vol 1203 (2010) ; Materials Research Society SP - 1 EP - 6 ER - TY - JOUR A1 - Wagner, Torsten A1 - Werner, Frederik A1 - Miyamoto, K. A1 - Schöning, Michael Josef A1 - Yoshinobu, T. T1 - A high-density multi-point LAPS set-up using a VCSEL array and FPGA control JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 1483 EP - 1486 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Krämer, Melina A1 - Abouzar, Maryam H. A1 - Pita, Marcos A1 - Katz, Evgeny A1 - Schöning, Michael Josef T1 - Interfacing of biocomputing systems with silicon chips: Enzyme logic gates based on field-effect devices JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 682 EP - 685 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Wagner, Holger A1 - Schöning, Michael Josef T1 - Functional testing and characterisation of (bio-)chemical sensors on wafer level JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 835 EP - 838 ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Mimura, Shuhei A1 - Kanoh, Shin`ichiro A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - Constant-phase-mode operation of the light-addressable potentiometric sensor JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 1487 EP - 1490 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirchner, Patrick A1 - Li, B. A1 - Spelthahn, H. A1 - Henkel, H. A1 - Friedrich, P. A1 - Kolstad, J. A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Thin-film calorimetric H2O2 gas sensor for the validation of germicidal effectivity in aseptic filling processes JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 983 EP - 986 ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Ingebrandt, S. A1 - Poghossian, Arshak A1 - Zhang, Y. A1 - Vu, X. T. A1 - Moritz, W. A1 - Schöning, Michael Josef T1 - Nanoplate field-effect capacitive (bio-)chemical sensor array based on SOI structure JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 670 EP - 673 ER - TY - JOUR A1 - Gasparyan, F. V. A1 - Poghossian, Arshak A1 - Vitusevich, S. A. A1 - Petrychuk, M. V. A1 - Sydoruk, V. A. A1 - Surmalyan, A. V. A1 - Siqueira, J. R. A1 - Oliveira, O. N. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Low Frequency Noise In Electrolyte-Gate Field-Effect Devices Functionalized With Dendrimer/Carbon-Nanotube Multilayers JF - Noise and fluctuations : 20th International Conference on Noise and Fluctuations, ICNF 2009, Pisa, Italy, 14 - 19 June 2009 / ed. Massimo Macucci; Giovanni Basso Y1 - 2009 SN - 9780735406650 N1 - AIP conference proceedings ; 1129 ; International Conference on Noise and Fluctuations ; (20, 2009, Pisa) SP - 133 EP - 136 PB - American Inst. of Physics CY - Melville, NY ER - TY - JOUR A1 - Buniatyan, Vahe V. A1 - Matirosyan, N. A1 - Abouzar, Maryam H. A1 - Schubert, J. A1 - Zander, W. A1 - Gevorgian, S. A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Capacitive field-effect pH sensor based on an electrolyte-ferroelectric-insulator-semiconductor structure JF - SENSOR 2009 : : 14th International Conference on Sensors, Technologies, Electronics and Applications; Nürnberg, Germany, 26 - 28 May 2009; proceedings; [part of] Sensor + Test Conference 2009 / AMA, Fachverband für Sensorik e.V Y1 - 2009 SN - 9783981099355 N1 - AMA, Fachverband für Sensorik ; Sensor International Conference ; (14 : ; 2009.05.26-28 : ; Nürnberg) SP - 317 EP - 322 PB - AMA Service CY - Wunstorf ER - TY - JOUR A1 - Linder, Peter A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Kayser, Peter A1 - Porst, Dariusz A1 - Artmann, Gerhard T1 - High-throughput testing of mechanical forces generated in thin cell and tissue layers JF - Tissue Engineering. 13 (2007), H. 7 Y1 - 2007 SN - 1076-3279 N1 - Meeting abstract 433 SP - 1778 EP - 1778 ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Maki, Rafael M. A1 - Paulovich, Fernando V. A1 - Werner, Frederik A1 - Poghossian, Arshak A1 - Oliveira, Maria C. F. de A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Use of Information Visualization Methods Eliminating Cross Talk in Multiple Sensing Units Investigated for a Light-Addressable Potentiometric Sensor JF - Analytical Chemistry (2010) Y1 - 2010 SN - 0003-2700 SP - 61 EP - 65 ER - TY - JOUR A1 - Siqueira, José R. Jr. A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Penicillin biosensor based on a capacitive field-effect structure functionalized with a dendrimer/carbon nanotube multilayer JF - Biosensors and Bioelectronics. 25 (2009), H. 2 Y1 - 2009 SN - 0956-5663 SP - 497 EP - 501 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Razavi, A. A1 - Bäcker, Matthias A1 - Bijnens, N. A1 - Williams, O. A. A1 - Haenen, K. A1 - Moritz, W. A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Nanocrystalline-diamond thin films with high pH and penicillin sensitivity prepared on a capacitive Si–SiO2 structure JF - Electrochimica Acta. 54 (2009), H. 25 Y1 - 2009 SN - 0013-4686 SP - 5981 EP - 5985 ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Self-aligned nanogaps and nanochannels via conventional photolithography and pattern-size reduction technique JF - Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI Y1 - 2009 SN - 0013-4686 SP - 6010 EP - 6014 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Turek, M. A1 - Heiden, W. A1 - Riesen, A. A1 - Chhabda, T. A. A1 - Schubert, J. A1 - Krüger, P. A1 - Keusgen, M. T1 - Artificial intelligence/fuzzy logic method for analysis of combined signals from heavy metal chemical sensors JF - Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI Y1 - 2009 SN - 0013-4686 SP - 6082 EP - 6088 PB - Elsevier CY - New York ER - TY - JOUR A1 - Bäcker, Matthias A1 - Beging, Stefan A1 - Biselli, Manfred A1 - Poghossian, Arshak A1 - Wang, J. A1 - Zang, Werner A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Concept for a solid-state multi-parameter sensor system for cell-culture monitoring JF - Electrochimica Acta. 54 (2009), H. 25 Sp. Iss. SI Y1 - 2009 SN - 0013-4686 SP - 6107 EP - 6112 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ullrich, Sebastian A1 - Grottke, Oliver A1 - Rossaint, Rolf A1 - Staat, Manfred A1 - Deserno, Thomas M. A1 - Kuhlen, Torsten T1 - Virtual Needle Simulation with Haptics for Regional Anaesthesia Y1 - 2010 N1 - IEEE Virtual Reality 2010, Workshop on Medical Virtual Environments, Waltham, MA, USA, March 21, 2010 SP - 1 EP - 3 ER - TY - JOUR A1 - Siqueira, José R. Jr. A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Associating biosensing properties with the morphological structure of multilayers containing carbon nanotubes on field-effect devices JF - Physica status solidi (a). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 781 EP - 786 ER - TY - JOUR A1 - Nguyen, N.-H. A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred T1 - A hyperelastic model of biological tissue materials in tubular organs Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 12 ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Vu, Khoi Duc A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - A primal-dual algorithm for shakedown analysis of elastic-plastic bounded linearly kinematic hardening bodies Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - JOUR A1 - Grottke, O. A1 - Braunschweig, T. A1 - Philippen, B. A1 - Gatzweiler, Karl-Heinz A1 - Gronloh, N. A1 - Staat, Manfred A1 - Rossaint, R. A1 - Tolba, R. T1 - A New Model for Blunt Liver Injuries in the Swine JF - European Surgical Research. 44 (2010), H. 2 Y1 - 2010 SN - 1421-9921 SP - 65 EP - 73 ER -