TY - JOUR A1 - Staat, Manfred A1 - Sponagel, Stefan A1 - Nguyen, Nhu Huynh T1 - Experiment and material model for soft tissue materials JF - Constitutive models for rubber VI : proceedings of the sixth European Conference on Constitutive Models for Rubber, Dresden, Germany, 7 - 10 September 2009 / eds. Gert Heinrich ... Y1 - 2010 SN - 978-0-415-56327-7 SP - 465 EP - 470 PB - CRC Press CY - Boca Raton [u.a.] ER - TY - JOUR A1 - Staat, Manfred A1 - Schwartz, M. A1 - Lang, H. A1 - Wirtz, K. A1 - Heitzer, M. T1 - Design by Analysis of Pressure Components by non-linear Optimization JF - The 10th International Conference on Pressure Vessel Technology, July 7-10, 2003, Vienna, Austria, Proceedings ICPVT-10 / Zeman, J. L. [ed] Y1 - 2003 SN - 3950152814 SP - 59 EP - 65 PB - ÖGS, Österreichische Gesellschaft für Schweißtechnik CY - Wien ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael T1 - Limit and shakedown analysis for plastic design N2 - Limit and shakedown theorems are exact theories of classical plasticity for the direct computation of safety factors or of the load carrying capacity under constant and varying loads. Simple versions of limit and shakedown analysis are the basis of all design codes for pressure vessels and pipings. Using Finite Element Methods more realistic modeling can be used for a more rational design. The methods can be extended to yield optimum plastic design. In this paper we present a first implementation in FE of limit and shakedown analyses for perfectly plastic material. Limit and shakedown analyses are done of a pipe–junction and a interaction diagram is calculated. The results are in good correspondence with the analytic solution we give in the appendix. KW - Einspielen KW - Traglast KW - Finite-Elemente-Methode KW - Traglastanalyse KW - Einspielanalyse KW - FEM KW - limit analysis KW - shakedown analysis Y1 - 1997 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael T1 - The restricted influence of kinematic hardening on shakedown loads N2 - Structural design analyses are conducted with the aim of verifying the exclusion of ratcheting. To this end it is important to make a clear distinction between the shakedown range and the ratcheting range. In cyclic plasticity more sophisticated hardening models have been suggested in order to model the strain evolution observed in ratcheting experiments. The hardening models used in shakedown analysis are comparatively simple. It is shown that shakedown analysis can make quite stable predictions of admissible load ranges despite the simplicity of the underlying hardening models. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis. Both give identical or similar shakedown ranges. Structural shakedown analyses show that the loading may have a more pronounced effect than the hardening model. KW - Biomedizinische Technik KW - Einspielen KW - Shakedown KW - Ratcheting KW - Bruchmechanik KW - shakedown KW - material shakedown KW - linear kinematic hardening KW - nonlinear kinematic hardening KW - ratchetting Y1 - 2002 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael T1 - Direct static FEM approach to limit and shakedown analysis N2 - Safety and reliability of structures may be assessed indirectly by stress distributions. Limit and shakedown theorems are simplified but exact methods of plasticity that provide safety factors directly in the loading space. These theorems may be used for a direct definition of the limit state function for failure by plastic collapse or by inadaptation. In a FEM formulation the limit state function is obtained from a nonlinear optimization problem. This direct approach reduces considerably the necessary knowledge of uncertain technological input data, the computing time, and the numerical error. Moreover, the direct way leads to highly effective and precise reliability analyses. The theorems are implemented into a general purpose FEM program in a way capable of large-scale analysis. KW - Einspielen KW - Nichtlineare Optimierung KW - Shakedown KW - Shakedown KW - limit load KW - lower bound theorem KW - nonlinear optimization KW - reliability Y1 - 2000 ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael ED - Staat, Manfred ED - Heitzer, Michael T1 - Probabilistic limit and shakedown problems T2 - Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems Y1 - 2003 SN - 3-00-010001-6 N1 - NIC Series VL - 15 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - BOOK A1 - Staat, Manfred A1 - Heitzer, Michael T1 - Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems. Y1 - 2003 SN - 3-00-010001-6 N1 - NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M. PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - BOOK A1 - Staat, Manfred A1 - Heitzer, M. A1 - Yan, Ai-Min A1 - Khoi, Vu Duc A1 - Nguyen, Dang Hung A1 - Valdoire, F. A1 - Lahousse, A. T1 - Limit Analysis of Defects Y1 - 2000 SN - 0944-2952 N1 - Bericht des Forschungszentrums, Jül-3746, Jülich (2000) PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. A1 - Reiners, H. A1 - Schubert, F. T1 - Shakedown and ratchetting under tension–torsion loadings: analysis and experiments JF - Nuclear Engineering and Design. 225 (2003), H. 1 Y1 - 2003 SN - 0029-5493 SP - 11 EP - 26 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. A1 - Lang, H. A1 - Wirtz, K. T1 - Direct Finite Element Route for Design-by-Analysis of Pressure Components JF - International Journal of Pressure Vessels and Piping. 82 (2005), H. 1 Y1 - 2005 SN - 0308-0161 SP - 61 EP - 67 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Limit and Shakedown Analysis for Plastic Safety of Complex Structures JF - Transactions of the 14th International Conference on Structural Dynamics in Reactor Technology (SMiRT-14) / Livolant, M. [ed] Y1 - 1997 N1 - Vol. B, Paper B02/2 SP - 33 EP - 40 CY - Lyon ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Limit and Shakedown Analysis Using a General Purpose Finite Element Code JF - Proceedings of NAFEMS World Congress '97 on Design, Simulation & Optimisation : reliability & applicability of computational methods ; Stuttgart, Germany, 9 - 11 April 1997 Y1 - 1997 SN - 1-87437-620-4 SP - 522 EP - 533 PB - NAFEMS CY - Glasgow ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Reliability Analysis of Elasto-Plastic Structures under Variable Loads JF - Inelastic analysis of structures under variable loads : theory and engineering applications / Maier, G.; Weichert, D. [ed] Y1 - 2000 SN - 0-7923-6645-X SP - 269 EP - 288 PB - Kluwer Academic Publ. CY - Dordrecht ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Structural Reliability Analysis of Elasto-Plastic Structures JF - Safety and reliability : proceedings of ESREL '99, the Tenth European Conference on Safety and Reliability, Munich-Garching, Germany, 13 - 17 September 1999 / Schuëller, G. I.; Kafka, P. [eds] Y1 - 1999 SN - 90-5809-109-0 SP - 513 EP - 518 PB - Balkema CY - Rotterdam ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Limit and Shakedown Analysis with Uncertain Data JF - Stochastic optimization techniques : numerical methods and technical applications / Marti, K. [ed] Y1 - 2002 SN - 3-540-42889-5 SP - 241 EP - 254 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Probabilistic limit and shakedown problems JF - Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M. Y1 - 2003 SN - 3-00-010001-6 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, M. T1 - Basis reduction technique for limit and shakedown problems T2 - Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M.; Heitzer, M. Y1 - 2003 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0001-2018112115 SN - 3-00-010001-6 SP - 1 EP - 55 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - FEM-computation of load carrying capacity of highly loaded passive components by direct methods. Heitzer, M. ; Staat, M. JF - Nuclear Engineering and Design. 193 (1999), H. 3 Y1 - 1999 SN - 0029-5493 SP - 349 EP - 358 ER - TY - JOUR A1 - Staat, Manfred A1 - Fiorini, G. L. A1 - Lensa, W. von A1 - Burgazzi, L. T1 - Reliability Methods for Passive Safety Functions JF - Proceedings of the SMiRT 14 Post Conference Seminar No 18 on Passive Safety Features in Nuclear Installations Y1 - 1997 CY - Pisa ER - TY - BOOK A1 - Staat, Manfred A1 - Erni, Daniel T1 - Symposium Proceedings; 3rd YRA MedTech Symposium 2019: May 24 / 2019 / FH Aachen Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Staat, Manfred A1 - Duong, Minh Tuan T1 - Smoothed Finite Element Methods for Nonlinear Solid Mechanics Problems: 2D and 3D Case Studies T2 - Proceedings of the National Science and Technology Conference on Mechanical - Transportation Engineering (NSCMET 2016), 13th October 2016, Hanoi, Vietnam, Vol.2 N2 - The Smoothed Finite Element Method (SFEM) is presented as an edge-based and a facebased techniques for 2D and 3D boundary value problems, respectively. SFEMs avoid shortcomings of the standard Finite Element Method (FEM) with lower order elements such as overly stiff behavior, poor stress solution, and locking effects. Based on the idea of averaging spatially the standard strain field of the FEM over so-called smoothing domains SFEM calculates the stiffness matrix for the same number of degrees of freedom (DOFs) as those of the FEM. However, the SFEMs significantly improve accuracy and convergence even for distorted meshes and/or nearly incompressible materials. Numerical results of the SFEMs for a cardiac tissue membrane (thin plate inflation) and an artery (tension of 3D tube) show clearly their advantageous properties in improving accuracy particularly for the distorted meshes and avoiding shear locking effects. Y1 - 2016 SP - 440 EP - 445 ER - TY - BOOK A1 - Staat, Manfred A1 - Digel, Ilya A1 - Trzewik, Jürgen A1 - Sielemann, Stefanie A1 - Erni, Daniel A1 - Zylka, Waldemar T1 - Symposium Proceedings; 4th YRA MedTech Symposium 2024 : February 1 / 2024 / FH Aachen Y1 - 2024 SN - 978-3-940402-65-3 U6 - http://dx.doi.org/10.17185/duepublico/81475 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - GEN A1 - Staat, Manfred A1 - Barry, Steve T1 - Continuum Mechanics with an Introduction to the Finite Element Method / Steve Barry; Manfred Staat. With extensions by Manfred Staat. N2 - Contents: 1 Introduction 2 One Dimensional Continuum Mechanics 3 Tensors 4 Three Dimensional Stress and Strain 5 Conservation Laws 6 Contiunuum Modelling 7 Plain Problems 8 Questions 9 Reference Information KW - Technische Mechanik KW - Finite-Elemente-Methode Y1 - 2006 ER - TY - JOUR A1 - Staat, Manfred A1 - Baroud, G. A1 - Topcu, M. A1 - Sponagel, Stefan T1 - Soft Materials in Technology and Biology – Characteristics, Properties, and Parameter Identification JF - Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.) Y1 - 2008 SN - 978-3-540-75408-4 SP - 253 EP - 315 PB - Springer CY - Berlin ER - TY - JOUR A1 - Staat, Manfred A1 - Ballmann, J. T1 - Computation of impacts on elastic solids by methods of bicharacteristics JF - Computational Mechanics '88 : theory and applications ; proceedings of the International Conference on Computational Engineering Science April 10-14, 1988, Atlanta, GA, USA ; vol. 2 N2 - Shock waves, explosions, impacts or cavitation bubble collapses may generate stress waves in solids causing cracks or unexpected dammage due to focussing, physical nonlinearity or interaction with existing cracks. There is a growing interest in wave propagation, which poses many novel problems to experimentalists and theorists. KW - Bicharakteristikenverfahren KW - Elastizität KW - elastic solids KW - bicharacteristics Y1 - 1988 SP - 1719 EP - 1722 ER - TY - JOUR A1 - Staat, Manfred A1 - Ballmann, J. T1 - Wave Propagation and Focussing in Plates JF - Impact loading and dynamic behaviour of materials : Papers presented at the International Conference on Impact Loading and Dynamic Behaviour of Materials, Vol. 2 / Chiem, C. Y.; Kunze, L. (u.a.) [eds] Y1 - 1988 PB - DGM Informationsges. CY - Oberursel ER - TY - CHAP A1 - Staat, Manfred A1 - Ballmann, J. T1 - Fundamental aspects of numerical methods for the propagation of multi-dimensional nonlinear waves in solids T2 - Nonlinear hyperbolic equations : theory, computations methods, and applications ; proceedings of the 2nd International Conference on Nonlinear Hyperbolic Problems, Aachen N2 - The nonlinear scalar constitutive equations of gases lead to a change in sound speed from point to point as would be found in linear inhomogeneous (and time dependent) media. The nonlinear tensor constitutive equations of solids introduce the additional local effect of solution dependent anisotropy. The speed of a wave passing through a point changes with propagation direction and its rays are inclined to the front. It is an open question whether the widely used operator splitting techniques achieve a dimensional splitting with physically reasonable results for these multi-dimensional problems. May be this is the main reason why the theoretical and numerical investigations of multi-dimensional wave propagation in nonlinear solids are so far behind gas dynamics. We hope to promote the subject a little by a discussion of some fundamental aspects of the solution of the equations of nonlinear elastodynamics. We use methods of characteristics because they only integrate mathematically exact equations which have a direct physical interpretation. KW - Nichtlineare Welle KW - Nichtlineare Gleichung KW - Festkörper KW - Elastodynamik KW - Multi-dimensional wave propagation KW - nonlinear solids KW - nonlinear tensor constitutive equation Y1 - 1989 SP - 574 EP - 588 ER - TY - JOUR A1 - Staat, Manfred T1 - Problems and Chances for Probabilistic Fracture Mechanics in the Analysis of Steel Pressure Boundary Reliability JF - Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994 Y1 - 1996 N1 - IAEA-TECDOC-920 ; Onlinezugriff erfolgt auf die überarb. Ausg. 2006 SP - 43 EP - 55 CY - Vienna ER - TY - JOUR A1 - Staat, Manfred T1 - Sensitivity of and Influences on the Reliability of an HTR-Module Primary Circuit Pressure Boundary JF - Transactions of the 12th International Conference on Structural Mechanics in Reactor Technology (SMiRT-12) / Kussmaul, K. [ed] Y1 - 1993 SN - 0-444-81515-5 N1 - Vol. M, Paper MG10/2 SP - 147 EP - 152 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Staat, Manfred T1 - Reliability of the Primary Circuit Pressure Boundary of an HTR-Module under Accident Conditions JF - Safety and reliability assessment : an integral approach ; ESREL'93 ; proceedings of the European Safety and Reliability Conference, Munich, Germany, May 10th - 12th 1993 / Kafka, P. [ed] Y1 - 1993 SN - 0-444-81561-9 SP - 331 EP - 342 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Staat, Manfred T1 - Some Achievements of the European Project LISA for FEM Based Limit and Shakedown Analysis JF - Computational mechanics : developments and applications, 2002 : presented at the 2002 ASME Pressure Vessels and Piping Conference, Vancouver, British Columbia, Canada, August 5 - 9. / Badie, N. [ed] Y1 - 2002 SN - 0791846520 N1 - Serie PVP ; vol. 441. SP - 177 EP - 185 PB - American Society of Mechanical Engineers CY - New York ER - TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels JF - Nuclear Engineering and Design. 234 (2004), H. 1-3 Y1 - 2004 SN - 0029-5493 SP - 25 EP - 43 ER - TY - JOUR A1 - Staat, Manfred T1 - Local and global collapse pressure of longitudinally flawed pipes and cylindrical vessels JF - International Journal of Pressure Vessels and Piping. 82 (2005), H. 3 Y1 - 2005 SN - 0308-0161 SP - 217 EP - 225 ER - TY - JOUR A1 - Staat, Manfred T1 - Failure probabilities of the primary circuit pressure boundary of an HTR-Module for process heat generation under accident conditions for different failure modes JF - Nuclear Engineering and Design. 144 (1993), H. 1 Y1 - 1993 SN - 0029-5493 SP - 53 EP - 67 ER - TY - JOUR A1 - Staat, Manfred T1 - Reliability of an HTR-module primary circuit pressure boundary Influences, sensitivity, and comparison with a PWR JF - Nuclear Engineering and Design. 158 (1995), H. 2-3 Y1 - 1995 SN - 0029-5493 SP - 333 EP - 340 ER - TY - JOUR A1 - Staat, Manfred T1 - Probabilistic assessment of the fracture mechanics behaviour of an HTR-module primary circuit pressure boundary JF - Nuclear Engineering and Design. 160 (1996), H. 1-2 Y1 - 1996 SN - 0029-5493 SP - 221 EP - 236 ER - TY - JOUR A1 - Staat, Manfred T1 - Limit and shakedown analysis under uncertainty JF - International journal of computational methods : IJCM Y1 - 2013 SN - 0219-8762 SP - Publ. online PB - World Scientific Publishing CY - Singapore ER - TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels N2 - Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data. KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohr KW - Rohrbruch KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohrbruch KW - Fehlerstellen KW - pipes KW - vessels KW - load limit KW - burst tests KW - burst pressure KW - flaw Y1 - 2004 ER - TY - JOUR A1 - Staat, Manfred T1 - Cyclic plastic deformation tests to verify FEM-based shakedown analyses N2 - Fatigue analyses are conducted with the aim of verifying that thermal ratcheting is limited. To this end it is important to make a clear distintion between the shakedown range and the ratcheting range (continuing deformation). As part of an EU-supported research project, experiments were carried out using a 4-bar model. The experiment comprised a water-cooled internal tube, and three insulated heatable outer test bars. The system was subjected to alternating axial forces, superimposed with alternating temperatures at the outer bars. The test parameters were partly selected on the basis of previous shakedown analyses. During the test, temperatures and strains were measured as a function of time. The loads and the resulting stresses were confirmed on an ongoing basis during performance of the test, and after it. Different material models were applied for this incremental elasto-plastic analysis using the ANSYS program. The results of the simulation are used to verify the FEM-based shakedown analysis. KW - Materialermüdung KW - Einspielen KW - Materialermüdung KW - shakedown analyses KW - thermal ratcheting KW - fatigue analyses Y1 - 2001 ER - TY - JOUR A1 - Staat, Manfred T1 - Local and global collapse pressure of longitudinally flawed pipes and cylindrical vessels N2 - Limit loads can be calculated with the finite element method (FEM) for any component, defect geometry, and loading. FEM suggests that published long crack limit formulae for axial defects under-estimate the burst pressure for internal surface defects in thick pipes while limit loads are not conservative for deep cracks and for pressure loaded crack-faces. Very deep cracks have a residual strength, which is modelled by a global collapse load. These observations are combined to derive new analytical local and global collapse loads. The global collapse loads are close to FEM limit analyses for all crack dimensions. KW - Finite-Elemente-Methode KW - Grenzwertberechnung KW - Axialbelastung KW - FEM KW - Grenzwertberechnung KW - Axialbelastung KW - Traglastanalyse KW - Limit analysis KW - Global and local collapse KW - Axially cracked pipe KW - Pressure loaded crack-face Y1 - 2005 ER - TY - JOUR A1 - Staat, Manfred T1 - Direct finite element route for design-by-analysis of pressure components N2 - In the new European standard for unfired pressure vessels, EN 13445-3, there are two approaches for carrying out a Design-by-Analysis that cover both the stress categorization method (Annex C) and the direct route method (Annex B) for a check against global plastic deformation and against progressive plastic deformation. This paper presents the direct route in the language of limit and shakedown analysis. This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for mechanical and thermal actions. One observation from the examples is that the so-called 3f (3Sm) criterion fails to be a reliable check against progressive plastic deformation. Precise conditions are given, which greatly restrict the applicability of the 3f criterion. KW - Einspielen KW - Plastizität KW - Deformation KW - Analytischer Zulaessigkeitsnachweis KW - Einspiel-Analyse KW - fortschreitende plastische Deformation KW - alternierend Verformbarkeit KW - Einspiel-Kriterium KW - Design-by-analysis KW - Shakedown analysis KW - Progressive plastic deformation KW - Alternating plasticity KW - Shakedown criterion Y1 - 2005 ER - TY - JOUR A1 - Staat, Manfred T1 - Shakedown and ratchetting under tension-torsion loadings: analysis and experiments N2 - Structural design analyses are conducted with the aim of verifying the exclusion of ratchetting. To this end it is important to make a clear distinction between the shakedown range and the ratchetting range. The performed experiment comprised a hollow tension specimen which was subjected to alternating axial forces, superimposed with constant moments. First, a series of uniaxial tests has been carried out in order to calibrate a bounded kinematic hardening rule. The load parameters have been selected on the basis of previous shakedown analyses with the PERMAS code using a kinematic hardening material model. It is shown that this shakedown analysis gives reasonable agreement between the experimental and the numerical results. A linear and a nonlinear kinematic hardening model of two-surface plasticity are compared in material shakedown analysis. KW - Einspielen KW - Einspielen KW - Ratchetting KW - Zug-Druck Belastung KW - shakedown KW - ratchetting KW - tension–torsion loading Y1 - 2003 ER - TY - JOUR A1 - Staat, Manfred T1 - Basis Reduction for the Shakedown Problem for Bounded Kinematic Hardening Material N2 - Limit and shakedown analysis are effective methods for assessing the load carrying capacity of a given structure. The elasto–plastic behavior of the structure subjected to loads varying in a given load domain is characterized by the shakedown load factor, defined as the maximum factor which satisfies the sufficient conditions stated in the corresponding static shakedown theorem. The finite element dicretization of the problem may lead to very large convex optimization. For the effective solution a basis reduction method has been developed that makes use of the special problem structure for perfectly plastic material. The paper proposes a modified basis reduction method for direct application to the two-surface plasticity model of bounded kinematic hardening material. The considered numerical examples show an enlargement of the load carrying capacity due to bounded hardening. KW - Finite-Elemente-Methode KW - Einspielen KW - Basis Reduktion KW - konvexe Optimierung KW - FEM KW - Druckgeräte KW - Basis reduction KW - Convex optimization KW - FEM KW - Shakedown analysis Y1 - 2000 ER - TY - CHAP A1 - Staat, Manfred T1 - Design by Analysis of Pressure Components by non-linear Optimization N2 - This paper presents the direct route to Design by Analysis (DBA) of the new European pressure vessel standard in the language of limit and shakedown analysis (LISA). This approach leads to an optimization problem. Its solution with Finite Element Analysis is demonstrated for some examples from the DBA-Manual. One observation from the examples is, that the optimisation approach gives reliable and close lower bound solutions leading to simple and optimised design decision. KW - Analytischer Zulaessigkeitsnachweis KW - FEM KW - Einspiel-Analyse KW - design-by-analysis KW - finite element analysis KW - limit and shakedown analysis Y1 - 2003 ER - TY - JOUR A1 - Staat, Manfred T1 - LISA - a European project for FEM-based limit and shakedown analysis N2 - The load-carrying capacity or the safety against plastic limit states are the central questions in the design of structures and passive components in the apparatus engineering. A precise answer is most simply given by limit and shakedown analysis. These methods can be based on static and kinematic theorems for lower and upper bound analysis. Both may be formulated as optimization problems for finite element discretizations of structures. The problems of large-scale analysis and the extension towards realistic material modelling will be solved in a European research project. Limit and shakedown analyses are briefly demonstrated with illustrative examples. KW - Einspielen KW - Traglast KW - Finite-Elemente-Methode KW - Traglastanalyse KW - Einspielanalyse KW - FEM KW - limit analysis KW - shakedown analysis Y1 - 2001 ER - TY - JOUR A1 - Staat, Manfred T1 - Direct FEM Limit and Shakedown Analysis with Uncertain Data N2 - The structural reliability with respect to plastic collapse or to inadaptation is formulated on the basis of the lower bound limit and shakedown theorems. A direct definition of the limit state function is achieved which permits the use of the highly effective first order reliability methods (FORM) is achieved. The theorems are implemented into a general purpose FEM program in a way capable of large-scale analysis. The limit state function and its gradient are obtained from a mathematical optimization problem. This direct approach reduces considerably the necessary knowledge of uncertain technological input data, the computing time, and the numerical error, leading to highly effective and precise reliability analyses. KW - Finite-Elemente-Methode KW - Einspielen KW - FEM KW - Einspielanalyse KW - shakedown KW - limit load KW - reliability analysis KW - FEM KW - direct method Y1 - 2000 ER - TY - GEN A1 - Staat, Manfred T1 - Engineering Mechanics. Lecture Notes. 2nd edition, translation of the 3rd corrected and extended German edition of "Technische Mechanik" N2 - English translation of the corrected lectures notes of Sebastian Krämer. Contents 0 Introduction to Mechanics 1 Statics of Rigid Bodies 2 Elastostatics (Strength of Materials) 3 Kinematics 4 Kinetics Literature KW - Technische Mechanik KW - Mechanics KW - Statics KW - Elastostatics KW - Kinematics KW - Kinetics Y1 - 2006 ER - TY - CHAP A1 - Staat, Manfred T1 - Problems and chances for probabilistic fracture mechanics in the analysis of steel pressure boundary reliability. - Überarb. Ausg. N2 - In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demon­strated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several addi­tional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings. KW - Bruchmechanik KW - probabilistic fracture mechanics KW - PFM Y1 - 2006 ER - TY - JOUR A1 - Staat, Manfred T1 - Limit and shakedown analysis under uncertainty JF - Tap chi Khoa hoc & ung dung - Dai hoc Ton Duc Thang Y1 - 2012 N1 - = Journal of Applied Sciences - Ton Duc Thang University VL - 19 SP - 45 EP - 47 ER - TY - JOUR A1 - Schieren, Mark A1 - Kleinschmidt, Joris A1 - Schmutz, Axel A1 - Loop, Torsten A1 - Gatzweiler, Karl-Heinz A1 - Staat, Manfred A1 - Wappler, Frank A1 - Defosse, Jerome T1 - Comparison of forces acting on maxillary incisors during tracheal intubation with different laryngoscopy techniques: a blinded manikin study JF - Anaesthesia Y1 - 2019 SN - 1365-2044 U6 - http://dx.doi.org/10.1111/anae.14815 N1 - Die Anhänge "Table S1 (Impact of sex and level of training on dental force. Results presented as median (IQR [range]) and n (%))" und "Appendix S1 (Measurement technique.)" stehen unter "Supporting Information" zum Download bereit. VL - 74 IS - 12 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Rausch, Valentin A1 - Kahmann, Stephanie Lucina A1 - Baltschun, Christoph A1 - Staat, Manfred A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Pressure distribution to the distal biceps tendon at the radial tuberosity: a biomechanical study JF - The Journal of Hand Surgery N2 - Purpose Mechanical impingement at the narrow radioulnar space of the tuberosity is believed to be an etiological factor in the injury of the distal biceps tendon. The aim of the study was to compare the pressure distribution at the proximal radioulnar space between 2 fixation techniques and the intact state. Methods Six right arms and 6 left arms from 5 female and 6 male frozen specimens were used for this study. A pressure transducer was introduced at the height of the radial tuberosity with the intact distal biceps tendon and after 2 fixation methods: the suture-anchor and the cortical button technique. The force (N), maximum pressure (kPa) applied to the radial tuberosity, and the contact area (mm²) of the radial tuberosity with the ulna were measured and differences from the intact tendon were detected from 60° supination to 60° pronation in 15° increments with the elbow in full extension and in 45° and 90° flexion of the elbow. Results With the distal biceps tendon intact, the pressures during pronation were similar regardless of extension and flexion and were the highest at 60° pronation with 90° elbow flexion (23.3 ± 53.5 kPa). After repair of the tendon, the mean peak pressure, contact area, and total force showed an increase regardless of the fixation technique. Highest peak pressures were found using the cortical button technique at 45° flexion of the elbow and 60° pronation. These differences were significantly different from the intact tendon. The contact area was significantly larger in full extension and 15°, 30°, and 60° pronation using the cortical button technique. Conclusions Pressures on the distal biceps tendon at the radial tuberosity increase during pronation, especially after repair of the tendon. Clinical relevance Mechanical impingement could play a role in both the etiology of primary distal biceps tendon ruptures and the complications occurring after fixation of the tendon using certain techniques. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jhsa.2020.01.006 SN - 0363-5023 VL - 45 IS - 8 SP - 776.e1 EP - 776.e9 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Rausch, Valentin A1 - Harbrecht, Andreas A1 - Kahmann, Stephanie Lucina A1 - Fenten, Thomas A1 - Jovanovic, Nebojsa A1 - Hackl, Michael A1 - Müller, Lars P. A1 - Staat, Manfred A1 - Wegmann, Kilian T1 - Osteosynthesis of Phalangeal Fractures: Biomechanical Comparison of Kirschner Wires, Plates, and Compression Screws JF - The Journal of Hand Surgery N2 - Purpose The aim of this study was to compare several osteosynthesis techniques (intramedullary headless compression screws, T-plates, and Kirschner wires) for distal epiphyseal fractures of proximal phalanges in a human cadaveric model. Methods A total of 90 proximal phalanges from 30 specimens (index, ring, and middle fingers) were used for this study. After stripping off all soft tissue, a transverse distal epiphyseal fracture was simulated at the proximal phalanx. The 30 specimens were randomly assigned to 1 fixation technique (30 per technique), either a 3.0-mm intramedullary headless compression screw, locking plate fixation with a 2.0-mm T-plate, or 2 oblique 1.0-mm Kirschner wires. Displacement analysis (bending, distraction, and torsion) was performed using optical tracking of an applied random speckle pattern after osteosynthesis. Biomechanical testing was performed with increasing cyclic loading and with cyclic load to failure using a biaxial torsion-tension testing machine. Results Cannulated intramedullary compression screws showed significantly less displacement at the fracture site in torsional testing. Furthermore, screws were significantly more stable in bending testing. Kirschner wires were significantly less stable than plating or screw fixation in any cyclic load to failure test setup. Conclusions Intramedullary compression screws are a highly stable alternative in the treatment of transverse distal epiphyseal phalangeal fractures. Kirschner wires seem to be inferior regarding displacement properties and primary stability. Clinical relevance Fracture fixation of phalangeal fractures using plate osteosynthesis may have the advantage of a very rigid reduction, but disadvantages such as stiffness owing to the more invasive surgical approach and soft tissue irritation should be taken into account. Headless compression screws represent a minimally invasive choice for fixation with good biomechanical properties. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jhsa.2020.04.010 SN - 0363-5023 VL - 45 IS - 10 SP - 987.e1 EP - 987.e8 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Raman, Aravind Hariharan A1 - Jung, Alexander A1 - Horváth, András A1 - Becker, Nadine A1 - Staat, Manfred ED - Staat, Manfred ED - Erni, Daniel T1 - Modification of a computer model of human stem cell-derived cardiomyocyte electrophysiology based on Patch-Clamp measurements T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - Human induced pluripotent stem cells (hiPSCs) have shown to be promising in disease studies and drug screenings [1]. Cardiomyocytes derived from hiPSCs have been extensively investigated using patch-clamping and optical methods to compare their electromechanical behaviour relative to fully matured adult cells. Mathematical models can be used for translating findings on hiPSCCMs to adult cells [2] or to better understand the mechanisms of various ion channels when a drug is applied [3,4]. Paci et al. (2013) [3] developed the first model of hiPSC-CMs, which they later refined based on new data [3]. The model is based on iCells® (Fujifilm Cellular Dynamics, Inc. (FCDI), Madison WI, USA) but major differences among several cell lines and even within a single cell line have been found and motivate an approach for creating sample-specific models. We have developed an optimisation algorithm that parameterises the conductances (in S/F=Siemens/Farad) of the latest Paci et al. model (2018) [5] using current-voltage data obtained in individual patch-clamp experiments derived from an automated patch clamp system (Patchliner, Nanion Technologies GmbH, Munich). Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 10 EP - 11 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Vu, Khoi Duc A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - A primal-dual algorithm for shakedown analysis of elastic-plastic bounded linearly kinematic hardening bodies Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - An Upper Bound Algorithm for Limit and Shakedown Analysis of Bounded Linearly Kinematic Hardening Structures JF - Limit State of Materials and Structures : Direct Methods 2. Saxcé, Géry de (Hrsg.) Y1 - 2013 SN - 978-94-007-5424-9 SP - 71 EP - 87 PB - Springer CY - Dordrecht ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - FEM-based shakedown analysis of hardening structures JF - Asia Pacific journal on computational engineering N2 - This paper develops a new finite element method (FEM)-based upper bound algorithm for limit and shakedown analysis of hardening structures by a direct plasticity method. The hardening model is a simple two-surface model of plasticity with a fixed bounding surface. The initial yield surface can translate inside the bounding surface, and it is bounded by one of the two equivalent conditions: (1) it always stays inside the bounding surface or (2) its centre cannot move outside the back-stress surface. The algorithm gives an effective tool to analyze the problems with a very high number of degree of freedom. Our numerical results are very close to the analytical solutions and numerical solutions in literature. Y1 - 2014 U6 - http://dx.doi.org/10.1186/2196-1166-1-4 SN - 2196-1166 (E-Journal) IS - 1 SP - Article No. 4 PB - SpringerOpen CY - Berlin ER - TY - CHAP A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - A simplification for shakedown analysis of hardening structures T2 - Conference proceedings of the YIC GACM 2015 : 3rd ECCOMAS Young Investigators Conference and 6th GACM Colloquium on Computational Mechanics , Aachen , Germany, 20.07.2015 - 23.07.2015 / ed.: Stefanie Elgeti ; Jaan-Willem Simon Y1 - 2015 SP - 1 EP - 4 PB - RWTH Aachen University CY - Aachen ER - TY - CHAP A1 - Pham, Phu Tinh A1 - Nguyen, Thanh Ngoc A1 - Staat, Manfred T1 - FEM based shakedown analysis of hardening structures T2 - Proceedings International Conference on Advances in Computational Mechanics (ACOME) Y1 - 2012 N1 - International Conference on Advances in Computational Mechanics (ACOME), August 14-16, 2012, Ho Chi Minh City, Vietnam SP - 870 EP - 882 ER - TY - JOUR A1 - Novacek, V. A1 - Tran, Thanh Ngoc A1 - Klinge, U. A1 - Tolba, R. H. A1 - Staat, Manfred A1 - Bronson, D. G. A1 - Miesse, A. M. A1 - Whiffen, J. A1 - Turquier, F. T1 - Finite element modelling of stapled colorectal end-to-end anastomosis : Advantages of variable height stapler design JF - Journal of Biomechanics N2 - The impact of surgical staplers on tissues has been studied mostly in an empirical manner. In this paper, finite element method was used to clarify the mechanics of tissue stapling and associated phenomena. Various stapling modalities and several designs of circular staplers were investigated to evaluate the impact of the device on tissues and mechanical performance of the end-to-end colorectal anastomosis. Numerical simulations demonstrated that a single row of staples is not adequate to resist leakage due to non-linear buckling and opening of the tissue layers between two adjacent staples. Compared to the single staple row configuration, significant increase in stress experienced by the tissue at the inner staple rows was observed in two and three rows designs. On the other hand, adding second and/or third staple row had no effect on strain in the tissue inside the staples. Variable height design with higher staples in outer rows significantly reduced the stresses and strains in outer rows when compared to the same configuration with flat cartridge. KW - Variable height stapler design KW - Anastomotic leakage KW - Finite element modelling KW - End-to-end colorectal anastomosis KW - Surgical staplers Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiomech.2012.07.021 SN - 1873-2380 VL - 45 IS - 115 SP - 2693 EP - 2697 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Nguyen, Nhu Huynh A1 - Duong, Minh Tuan A1 - Tran, Thanh Ngoc A1 - Pham, Phu Tinh A1 - Grottke, O. A1 - Tolba, R. A1 - Staat, Manfred T1 - Influence of a freeze–thaw cycle on the stress–stretch curves of tissues of porcine abdominal organs JF - Journal of Biomechanics N2 - The paper investigates both fresh porcine spleen and liver and the possible decomposition of these organs under a freeze–thaw cycle. The effect of tissue preservation condition is an important factor which should be taken into account for protracted biomechanical tests. In this work, tension tests were conducted for a large number of tissue specimens from twenty pigs divided into two groups of 10. Concretely, the first group was tested in fresh state; the other one was tested after a freeze-thaw cycle which simulates the conservation conditions before biomechanical experiments. A modified Fung model for isotropic behavior was adopted for the curve fitting of each kind of tissues. Experimental results show strong effects of the realistic freeze–thaw cycle on the capsule of elastin-rich spleen but negligible effects on the liver which virtually contains no elastin. This different behavior could be explained by the autolysis of elastin by elastolytic enzymes during the warmer period after thawing. Realistic biomechanical properties of elastin-rich organs can only be expected if really fresh tissue is tested. The observations are supported by tests of intestines. KW - Autolysis KW - Decomposition KW - Freeze–thaw process KW - Spleen KW - Liver Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jbiomech.2012.07.008 SN - 1873-2380 VL - 45 IS - 14 SP - 2382 EP - 2386 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Nguyen, N.-H. A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred T1 - A hyperelastic model of biological tissue materials in tubular organs Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 12 ER - TY - JOUR A1 - Michael, Hackl A1 - Mayer, Katharina A1 - Weber, Mareike A1 - Staat, Manfred A1 - van Riet, Roger A1 - Burkhart, Klau Josef A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - Plate osteosynthesis of proximal ulna fractures : a biomechanical micromotion analysis JF - The journal of hand surgery Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.jhsa.2017.05.014 SN - 0363-5023 VL - 42 IS - 10 SP - 834.e1 EP - 834.e7 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Meyer, Carolin A1 - Gaalen, Kerstin van A1 - Leschinger, Tim A1 - Scheyerer, Max J. A1 - Neiss, Wolfram F. A1 - Staat, Manfred A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Kyphoplasty of Osteoporotic Fractured Vertebrae: A Finite Element Analysis about Two Types of Cement JF - BioMed Research International Y1 - 2019 U6 - http://dx.doi.org/10.1155/2019/9232813 SP - Article ID 9232813 ER - TY - JOUR A1 - Linder, Peter A1 - Beckler, Matthias A1 - Doerr, Leo A1 - Stoelzle-Feix, Sonja A1 - Fertig, Niels A1 - Jung, Alexander A1 - Staat, Manfred A1 - Gossmann, Matthias T1 - A new in vitro tool to investigate cardiac contractility under physiological mechanical conditions JF - Journal of Pharmacological and Toxicological Methods Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.vascn.2019.05.162 SN - 1056-8719 VL - 99 IS - Article number 106595 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Levers, A. A1 - Staat, Manfred A1 - Laack, Walter van T1 - Analysis of the long-term effect of the MBST® nuclear magnetic resonance therapy on gonarthrosis JF - Orthopedic Practice Y1 - 2016 VL - 47 IS - 11 SP - 521 EP - 528 ER - TY - JOUR A1 - Leschinger, Tim A1 - Birgel, Stefan A1 - Hackl, Michael A1 - Staat, Manfred A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - A musculoskeletal shoulder simulation of moment arms and joint reaction forces after medialization of the supraspinatus footprint in rotator cuff repair JF - Computer Methods in Biomechanics and Biomedical Engineering Y1 - 2019 U6 - http://dx.doi.org/10.1080/10255842.2019.1572749 IS - Early view PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Leschinger, Tim A1 - Besch, Katharina A1 - Aydin, Cansu A1 - Staat, Manfred A1 - Scaal, Martin A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - Irreparable rotator cuff tears: a biomechanical comparison of superior capsuloligamentous complex reconstruction techniques and an interposition graft technique JF - The Orthopaedic Journal of Sports Medicine Y1 - 2019 U6 - http://dx.doi.org/10.1177/2325967119864590 VL - 7 IS - 8 SP - 1 EP - 5 ER - TY - JOUR A1 - Kühn, Raoul-Roman A1 - Haugner, Werner A1 - Staat, Manfred A1 - Sponagel, Stefan T1 - A Two Phase Mixture Model based on Bone Observation N2 - An optimization method is developed to describe the mechanical behaviour of the human cancellous bone. The method is based on a mixture theory. A careful observation of the behaviour of the bone material leads to the hypothesis that the bone density is controlled by the principal stress trajectories (Wolff’s law). The basic idea of the developed method is the coupling of a scalar value via an eigenvalue problem to the principal stress trajectories. On the one hand this theory will permit a prediction of the reaction of the biological bone structure after the implantation of a prosthesis, on the other hand it may be useful in engineering optimization problems. An analytical example shows its efficiency. KW - Knochen KW - Knochenbildung KW - Knochenchirugie KW - Strukturanalyse KW - Schwammknochen KW - Knochendichte KW - Wolffsches Gesetz KW - bone structure KW - bone density KW - Wolff's Law KW - cancellous bone Y1 - 2004 ER - TY - JOUR A1 - Knox, Ronald A1 - Bruggemann, Andrea A1 - Gossmann, Matthias A1 - Thomas, Ulrich A1 - Horváth, András A1 - Dragicevic, Elena A1 - Stoelzle-Feix, Sonja A1 - Fertig, Niels A1 - Jung, Alexander A1 - Raman, Aravind Hariharan A1 - Staat, Manfred A1 - Linder, Peter T1 - Combining physiological relevance and throughput for in vitro cardiac contractility measurement JF - Biophysical Journal N2 - Despite increasing acceptance of human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) in safety pharmacology, controversy remains about the physiological relevance of existing in vitro models for their mechanical testing. We hypothesize that existing signs of immaturity of the cell models result from an improper mechanical environment. We cultured hiPSC-CMs in a 96-well format on hyperelastic silicone membranes imitating their native mechanical environment, resulting in physiological responses to compound stimuli.We validated cell responses on the FLEXcyte 96, with a set of reference compounds covering a broad range of cellular targets, including ion channel modulators, adrenergic receptor modulators and kinase inhibitors. Acute (10 - 30 min) and chronic (up to 7 days) effects were investigated. Furthermore, the measurements were complemented with electromechanical models based on electrophysiological recordings of the used cell types.hiPSC-CMs were cultured on freely-swinging, ultra-thin and hyperelastic silicone membranes. The weight of the cell culture medium deflects the membranes downwards. Rhythmic contraction of the hiPSC-CMs resulted in dynamic deflection changes which were quantified by capacitive distance sensing. The cells were cultured for 7 days prior to compound addition. Acute measurements were conducted 10-30 minutes after compound addition in standard culture medium. For chronic treatment, compound-containing medium was replaced daily for up to 7 days. Electrophysiological properties of the employed cell types were recorded by automated patch-clamp (Patchliner) and the results were integrated into the electromechanical model of the system.Calcium channel agonist S Bay K8644 and beta-adrenergic stimulator isoproterenol induced significant positive inotropic responses without additional external stimulation. Kinase inhibitors displayed cardiotoxic effects on a functional level at low concentrations. The system-integrated analysis detected alterations in beating shape as well as frequency and arrhythmic events and we provide a quantitative measure of these. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.bpj.2019.11.3104 SN - 0006-3495 N1 - Raman, Arayind Hariharan im Artikel unter dem Namen: Raman, Alexander H. VL - 118 IS - Issue 3, Supplement 1 SP - 570a PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Knott, Thomas C. A1 - Sofronia, Raluca E. A1 - Gerressen, Marcus A1 - Law, Yuen A1 - Davidescu, Arjana A1 - Savii, George G. A1 - Gatzweiler, Karl-Heinz A1 - Staat, Manfred A1 - Kuhlen, Torsten W. T1 - Preliminary bone sawing model for a virtual reality-based training simulator of bilateral sagittal split osteotomy T2 - Biomedical simulation : 6th International Symposium, ISBMS 2014, Strasbourg, France, October 16-17, 2014 : proceedings (Lecture notes in computer science : vol. 8789) N2 - Successful bone sawing requires a high level of skill and experience, which could be gained by the use of Virtual Reality-based simulators. A key aspect of these medical simulators is realistic force feedback. The aim of this paper is to model the bone sawing process in order to develop a valid training simulator for the bilateral sagittal split osteotomy, the most often applied corrective surgery in case of a malposition of the mandible. Bone samples from a human cadaveric mandible were tested using a designed experimental system. Image processing and statistical analysis were used for the selection of four models for the bone sawing process. The results revealed a polynomial dependency between the material removal rate and the applied force. Differences between the three segments of the osteotomy line and between the cortical and cancellous bone were highlighted. KW - Bone sawing KW - virtual reality KW - training simulator Y1 - 2014 SN - 978-3-319-12057-7 (Online) SN - 978-3-319-12056-0 (Print) U6 - http://dx.doi.org/10.1007/978-3-319-12057-7_1 SP - 1 EP - 10 PB - Springer CY - Cham ER - TY - CHAP A1 - Kahmann, Stephanie Lucina A1 - Uschok, Stephan A1 - Wegmann, Kilian A1 - Müller, Lars-P. A1 - Staat, Manfred T1 - Biomechanical multibody model with refined kinematics of the elbow T2 - 6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK N2 - The overall objective of this study is to develop a new external fixator, which closely maps the native kinematics of the elbow to decrease the joint force resulting in reduced rehabilitation time and pain. An experimental setup was designed to determine the native kinematics of the elbow during flexion of cadaveric arms. As a preliminary study, data from literature was used to modify a published biomechanical model for the calculation of the joint and muscle forces. They were compared to the original model and the effect of the kinematic refinement was evaluated. Furthermore, the obtained muscle forces were determined in order to apply them in the experimental setup. The joint forces in the modified model differed slightly from the forces in the original model. The muscle force curves changed particularly for small flexion angles but their magnitude for larger angles was consistent. Y1 - 2018 ER - TY - CHAP A1 - Kahmann, Stephanie A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Müller, Lars-Peter A1 - Staat, Manfred ED - Erni, Daniel T1 - Impact of a proximal radial shortening osteotomy on the distribution of forces and the stability of the elbow T2 - 1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen N2 - The human arm consists of the humerus (upper arm), the medial ulna and the lateral radius (forearm). The joint between the humerus and the ulna is called humeroulnar joint and the joint between the humerus and the radius is called humeroradial joint. Lateral and medial collateral ligaments stabilize the elbow. Statistically, 2.5 out of 10,000 people suffer from radial head fractures [1]. In these fractures the cartilage is often affected. Caused by the injured cartilage, degenerative diseases like posttraumatic arthrosis may occur. The resulting pain and reduced range of motion have an impact on the patient’s quality of life. Until now, there has not been a treatment which allows typical loads in daily life activities and offers good long-term results. A new surgical approach was developed with the motivation to reduce the progress of the posttraumatic arthrosis. Here, the radius is shortened by 3 mm in the proximal part [2]. By this means, the load of the radius is intended to be reduced due to a load shift to the ulna. Since the radius is the most important stabilizer of the elbow it has to be confirmed that the stability is not affected. In the first test (Fig. 1 left), pressure distributions within the humeroulnar and humeroradial joints a native and a shortened radius were measured using resistive pressure sensors (I5076 and I5027, Tekscan, USA). The humerus was loaded axially in a tension testing machine (Z010, Zwick Roell, Germany) in 50 N steps up to 400 N. From the humerus the load is transmitted through both the radius and the ulna into the hand which is fixed on the ground. In the second test (Fig. 1 right), the joint stability was investigated using a digital image correlation system to measure the displacement of the ulna. Here, the humerus is fixed with a desired flexion angle and the unconstrained forearm lies on the ground. A rope connects the load actuator with a hook fixed in the ulna. A guide roller is used so that the rope pulls the ulna horizontally when a tensile load is applied. This creates a moment about the elbow joint with a maximum value of 7.5 Nm. Measurements were performed with varying flexion angles (0°, 30°, 60°, 90°, 120°). For both tests and each measurement, seven specimens were used. Student ́s t-test was employed to determine whether the mean values of the measurements in native specimen and operated specimens differ significantly. Y1 - 2016 U6 - http://dx.doi.org/10.17185/duepublico/40821 SP - 7 EP - 8 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Flight style optimization in ski jumping on normal, large, and ski flying hills JF - Journal of biomechanics Y1 - 2013 SN - 1873-2380 (E-Journal); 0021-9290 (Print) N1 - Corrigendum to “Flight style optimization in ski jumping on normal, large, and ski flying hills” [J. Biomech 47 (2014) 716-722] Journal of Biomechanics, 2018;71:313. VL - Vol. 47 IS - Iss. 3 SP - 716 EP - 722 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram ED - Onate, E. T1 - Optimization of the flight style in ski jumping T2 - 11th World Congress on Computational Mechanics (WCCM XI) ; 5th European Conference on Computational Mechanics (ECCM V) ; 6th European Conference on Computational Fluid Dynamics (ECFD VI) ; July 20 - 25, 2014, Barcelona Y1 - 2014 N1 - Das Paper wurde nach der Konferenz überarbeitet. SP - 799 EP - 810 ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Effect of wind on flight style optimisation in ski jumping T2 - 15th International Symposium on Computer Simulation in Biomechanics ; July 9th-11th 2015, Edinburgh, UK Y1 - 2016 SP - 53 EP - 54 PB - The University of Edinburgh ; Loughborough University CY - Edinburgh ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Corrigendum to “Flight style optimization in ski jumping on normal, large, and ski flying hills” [J. Biomech 47 (2014) 716–722] JF - Journals of Biomechanics Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.jbiomech.2018.02.001 SN - 0021-9290 N1 - refers to Journal of Biomechanics Vol 47, Issue 3, Pages 716-722: https://doi.org/10.1016/j.jbiomech.2013.11.021 SP - 313 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred ED - Erni, Daniel T1 - Computing olympic gold: Ski jumping as an example T2 - 1st YRA MedTech Symposium 2016 : April 8th / 2016 / University of Duisburg-Essen Y1 - 2016 SN - 978-3-940402-06-6 U6 - http://dx.doi.org/10.17185/duepublico/40821 SP - 54 EP - 55 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred T1 - Modeling and simulation of human induced pluripotent stem cell-derived cardiac tissue JF - GAMM - Mitteilungen der Gesellschaft für Angewandte Mathematik und Mechanik Y1 - 2019 U6 - http://dx.doi.org/10.1002/gamm.201900002 SN - 1522-2608 VL - 42 IS - 4 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred T1 - Erratum to "Modeling and simulation of human induced pluripotent stem cell-derived cardiac tissue" [GAMM-Mitteilungen, (2019), 42, 4, 10.1002/gamm.201900002] JF - GAMM-Mitteilungen Y1 - 2020 U6 - http://dx.doi.org/10.1002/gamm.202000011 SN - 1522-2608 N1 - Refers to: Modeling and simulation of human induced pluripotent stem cell-derived cardiac tissue. Alexander Jung, Manfred Staat. Volume 42, Issue 4. GAMM-Mitteilungen, 2019. https://doi.org/10.1002/gamm.201900002 VL - 43 IS - 4 PB - Wiley-VCH GmbH CY - Weinheim ER - TY - JOUR A1 - Jung, Alexander A1 - Müller, Wolfram A1 - Staat, Manfred T1 - Wind and fairness in ski jumping: A computer modelling analysis JF - Journal of Biomechanics N2 - Wind is closely associated with the discussion of fairness in ski jumping. To counter-act its influence on the jump length, the International Ski Federation (FIS) has introduced a wind compensation approach. We applied three differently accurate computer models of the flight phase with wind (M1, M2, and M3) to study the jump length effects of various wind scenarios. The previously used model M1 is accurate for wind blowing in direction of the flight path, but inaccuracies are to be expected for wind directions deviating from the tangent to the flight path. M2 considers the change of airflow direction, but it does not consider the associated change in the angle of attack of the skis which additionally modifies drag and lift area time functions. M3 predicts the length effect for all wind directions within the plane of the flight trajectory without any mathematical simplification. Prediction errors of M3 are determined only by the quality of the input data: wind velocity, drag and lift area functions, take-off velocity, and weight. For comparing the three models, drag and lift area functions of an optimized reference jump were used. Results obtained with M2, which is much easier to handle than M3, did not deviate noticeably when compared to predictions of the reference model M3. Therefore, we suggest to use M2 in future applications. A comparison of M2 predictions with the FIS wind compensation system showed substantial discrepancies, for instance: in the first flight phase, tailwind can increase jump length, and headwind can decrease it; this is opposite of what had been anticipated before and is not considered in the current wind compensation system in ski jumping. Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.jbiomech.2018.05.001 SN - 0021-9290 IS - 75 SP - 147 EP - 153 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Jung, Alexander A1 - Müller, Wolfram A1 - Staat, Manfred T1 - Optimization of the flight technique in ski jumping: the influence of wind Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.jbiomech.2019.03.023 IS - Early view PB - Elsevier CY - Amsterdam ER - TY - GEN A1 - Jung, Alexander A1 - Müller, Wolfram A1 - Staat, Manfred T1 - Corrigendum to “Wind and fairness in ski jumping: A computer modelling analysis” [J. Biomech. 75 (2018) 147–153] T2 - Journal of Biomechanics Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.jbiomech.2021.110690 SN - 0021-9290 N1 - Refers to: Alexander Jung, Wolfram Müller, Manfred Staat: Wind and fairness in ski jumping: A computer modelling analysis. Journal of Biomechanics, Volume 75. 25 June 2018. Pages 147-153. https://doi.org/10.1016/j.jbiomech.2018.05.001 VL - 128 IS - Article number: 110690 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Jung, Alexander A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - Electromechanical model of hiPSC-derived ventricular cardiomyocytes cocultured with fibroblasts T2 - 6th European Conference on Computational Mechanics (ECCM 6), 7th European Conference on Computational Fluid Dynamics (ECFD 7), 11-15 June 2018, Glasgow, UK N2 - The CellDrum provides an experimental setup to study the mechanical effects of fibroblasts co-cultured with hiPSC-derived ventricular cardiomyocytes. Multi-scale computational models based on the Finite Element Method are developed. Coupled electrical cardiomyocyte-fibroblast models (cell level) are embedded into reaction-diffusion equations (tissue level) which compute the propagation of the action potential in the cardiac tissue. Electromechanical coupling is realised by an excitation-contraction model (cell level) and the active stress arising during contraction is added to the passive stress in the force balance, which determines the tissue displacement (tissue level). Tissue parameters in the model can be identified experimentally to the specific sample. Y1 - 2018 ER - TY - JOUR A1 - Jayaraman, Chandrasekaran A1 - Mummidisetty, Chaitanya Krishna A1 - Loesch, Alexandra A1 - Kaur, Sandi A1 - Hoppe-Ludwig, Shenan A1 - Staat, Manfred A1 - Jayaraman, Arun T1 - Postural and metabolic benefits of using a forearm support walker in older adults with impairments JF - Archives of Physical Medicine and Rehabilitation Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.apmr.2018.10.001 SN - 0003-9993 VL - Volume 100 IS - Issue 4 SP - 638 EP - 647 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Jabbari, Medisa A1 - Bhattarai, Aroj A1 - Anding, Ralf A1 - Staat, Manfred ED - Erni, Daniel ED - Fischerauer, Alice ED - Himmel, Jörg ED - Seeger, Thomas ED - Thelen, Klaus T1 - Biomechanical simulation of different prosthetic meshes for repairing uterine/vaginal vault prolapse T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - http://dx.doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 SP - 118 EP - 119 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Hunker, Jan A1 - Jung, Alexander A1 - Goßmann, Matthias A1 - Linder, Peter A1 - Staat, Manfred ED - Staat, Manfred ED - Erni, Daniel T1 - Development of a tool to analyze the conduction speed in microelectrode array measurements of cardiac tissue T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - The discovery of human induced pluripotent stem cells reprogrammed from somatic cells [1] and their ability to differentiate into cardiomyocytes (hiPSC-CMs) has provided a robust platform for drug screening [2]. Drug screenings are essential in the development of new components, particularly for evaluating the potential of drugs to induce life-threatening pro-arrhythmias. Between 1988 and 2009, 14 drugs have been removed from the market for this reason [3]. The microelectrode array (MEA) technique is a robust tool for drug screening as it detects the field potentials (FPs) for the entire cell culture. Furthermore, the propagation of the field potential can be examined on an electrode basis. To analyze MEA measurements in detail, we have developed an open-source tool. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 7 EP - 8 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Perez-Viana, Daniel A1 - Simmen, Hans-Peter A1 - Neuhaus, Valentin A1 - Pape, Hans-Christoph A1 - Prescher, Andreas A1 - Ciritsis, Bernhard T1 - Biomechanical in vitro examination of a standardized low-volume tubular femoroplasty JF - Clinical Biomechanics N2 - Background Osteoporosis is associated with the risk of fractures near the hip. Age and comorbidities increase the perioperative risk. Due to the ageing population, fracture of the proximal femur also proves to be a socio-economic problem. Preventive surgical measures have hardly been used so far. Methods 10 pairs of human femora from fresh cadavers were divided into control and low-volume femoroplasty groups and subjected to a Hayes fall-loading fracture test. The results of the respective localization and classification of the fracture site, the Singh index determined by computed tomography (CT) examination and the parameters in terms of fracture force, work to fracture and stiffness were evaluated statistically and with the finite element method. In addition, a finite element parametric study with different position angles and variants of the tubular geometry of the femoroplasty was performed. Findings Compared to the control group, the work to fracture could be increased by 33.2%. The fracture force increased by 19.9%. The used technique and instrumentation proved to be standardized and reproducible with an average poly(methyl methacrylate) volume of 10.5 ml. The parametric study showed the best results for the selected angle and geometry. Interpretation The cadaver studies demonstrated the biomechanical efficacy of the low-volume tubular femoroplasty. The numerical calculations confirmed the optimal choice of positioning as well as the inner and outer diameter of the tube in this setting. The standardized minimally invasive technique with the instruments developed for it could be used in further comparative studies to confirm the measured biomechanical results. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.clinbiomech.2020.105104 VL - 80 IS - Art. 105104 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Horbach, Andreas A1 - Staat, Manfred T1 - Optical strain measurement for the modeling of surgical meshes and their porosity JF - Current Directions in Biomedical Engineering N2 - The porosity of surgical meshes makes them flexible for large elastic deformation and establishes the healing conditions of good tissue in growth. The biomechanic modeling of orthotropic and compressible materials requires new materials models and simulstaneoaus fit of deformation in the load direction as well as trannsversely to to load. This nonlinear modeling can be achieved by an optical deformation measurement. At the same time the full field deformation measurement allows the dermination of the change of porosity with deformation. Also the socalled effective porosity, which has been defined to asses the tisssue interatcion with the mesh implants, can be determined from the global deformation of the surgical meshes. Y1 - 2018 U6 - http://dx.doi.org/10.1515/cdbme-2018-0045 SN - 2364-5504 VL - Band 4 IS - 1 SP - 181 EP - 184 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Horbach, Andreas A1 - Duong, Minh Tuan A1 - Staat, Manfred T1 - Modelling of compressible and orthotropic surgical mesh implants based on optical deformation measurement JF - Journal of the mechanical behavior of biomedical materials Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.jmbbm.2017.06.012 SN - 1751-6161 VL - 74 SP - 400 EP - 410 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Heitzer, M. A1 - Staat, Manfred T1 - Direct FEM approach to design-by-analysis of pressurized components N2 - Abstracts of the ACHEMA 2000 - International Meeting on Chemical Engineering, Environmental Protection and Biotechnology, May 22 - 27, 2000. Frankfurt am Main. Achema 2000 : special edition / Linde. [Ed.: Linde AG. Red.: Volker R. Leski]. - Wiesbaden : Linde AG, 2000. - 56 p. : Ill., . - pp: 79 - 81 N2 - Abstracts der ACHEMA 2000 - International Meeting on Chemical Engineering, Environmental Protection and Biotechnology, May 22 - 27, 2000. Frankfurt am Main. KW - Finite-Elemente-Methode KW - Finite-Elemente-Methode KW - limit analysis KW - shakedown analysis Y1 - 2000 ER - TY - JOUR A1 - Hasan, Istabrak A1 - Keil, Ludger A1 - Staat, Manfred A1 - Wahl, Gerhard A1 - Bourauel, Christoph T1 - Determination of the frictional coefficient of the implant-antler interface : experimental approach JF - Biomedical Engineering / Biomedizinische Technik N2 - The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5–0.7 and 0.3–0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens. Y1 - 2012 SN - 1862-278X VL - 57 IS - 5 SP - 359 EP - 363 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Kahmann, Stephanie Lucina A1 - Heinze, Nicolai A1 - Staat, Manfred A1 - Neiss, Wolfram F. A1 - Scaal, Martin A1 - Müller, Lars P. T1 - Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow JF - Knee Surgery, Sports Traumatology, Arthroscopy Y1 - 2017 U6 - http://dx.doi.org/10.1007/s00167-017-4468-z SN - 1433-7347 VL - 25 IS - 7 SP - 2280 EP - 2288 PB - Springer CY - Berlin ER - TY - GEN A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Kahmann, Stephanie Lucina A1 - Heinze, Nicolai A1 - Staat, Manfred A1 - Neiss, Wolfram F. A1 - Scaal, Martin A1 - Müller, Lars P. T1 - Reply to the letter to the editor: shortening osteotomy of the proximal radius T2 - Knee Surgery, Sports Traumatology, Arthroscopy Y1 - 2017 U6 - http://dx.doi.org/10.1007/s00167-017-4666-8 VL - 25 IS - 10 SP - 3328 EP - 3329 ER - TY - JOUR A1 - Hackl, Michael A1 - Nacov, Julia A1 - Kammerlohr, Sandra A1 - Staat, Manfred A1 - Buess, Eduard A1 - Leschinger, Tim A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Intratendinous Strain Variations of the Supraspinatus Tendon Depending on Repair Technique: A Biomechanical Analysis Regarding the Cause of Medial Cuff Failure JF - The American Journal of Sports Medicine Y1 - 2021 U6 - http://dx.doi.org/10.1177/03635465211006138 SN - 1552-3365 SN - 0363-5465 VL - 49 IS - 7 SP - 1847 EP - 1853 PB - Sage CY - London ER - TY - JOUR A1 - Hackl, Michael A1 - Müller, Lars-Peter A1 - Staat, Manfred A1 - Kahmann, Stephanie Lucina A1 - Wegmann, Kilian T1 - Proximal phalangeal neck fractures of the hand — a biomechanical comparison of three fixation techniques JF - Knee surgery, sports traumatology, arthroscopy N2 - Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 148 EP - 149 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hackl, Michael A1 - Leschinger, T. A1 - Staat, Manfred A1 - Müller, Lars-Peter A1 - Wegmann, Kilian T1 - Reconstruction of the interosseous membrane in the Essex Lopresti lesion — a biomechanical evaluation JF - Knee surgery, sports traumatology, arthroscopy N2 - Surgical reconstruction of the interosseous membrane (IOM) could restore longitudinal forearm stability to avoid persisting disability due to capituloradial and ulnocarpal impingement in Essex Lopresti lesions. This biomechanical study aimed to assess longitudinal forearm stability of intact specimens, after sectioning of the IOM and after reconstruction with a TightRope construct using either a single or double bundle technique. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 130 EP - 131 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hackl, Michael A1 - Kahmann, Stephanie Lucina A1 - Wegmann, Kilian A1 - Ries, Christian A1 - Staat, Manfred A1 - Müller, Lars-Peter T1 - Shortening osteotomy of the proximal radius — a treatment option for isolated osteoarthritis of the lateral column of the elbow joint? JF - Knee surgery, sports traumatology, arthroscopy N2 - Treatment of posttraumatic osteoarthritis of the radial column of the elbow joint remains a challenging yet common issue. While partial joint replacement leads to high revision rates, radial head excision has shown to severely increase joint instability. Shortening osteotomy of the radius could be an option to decrease the contact pressure of the radiohumeral joint and thereby pain levels without causing valgus instability. Hence, the aim of this biomechanical study was to evaluate the effects of radial shortening on axial load distribution and valgus stability of the elbow joint. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 128 EP - 129 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hackl, M. A1 - Andermahr, J. A1 - Staat, Manfred A1 - Bremer, I. A1 - Borggrefe, J. A1 - Prescher, A. A1 - Müller, L. P. A1 - Wegmann, K. T1 - Suture button reconstruction of the central band of the interosseous membrane in Essex-Lopresti lesions: a comparative biomechanical investigation JF - The Journal of Hand Surgery (European Volume) Y1 - 2017 U6 - http://dx.doi.org/10.1177/1753193416665943 SN - 2043-6289 (Online) SN - 1753-1934 (Print) VL - 42 IS - 4 SP - 370 EP - 376 PB - Sage CY - London ER - TY - JOUR A1 - Grottke, O. A1 - Braunschweig, T. A1 - Philippen, B. A1 - Gatzweiler, Karl-Heinz A1 - Gronloh, N. A1 - Staat, Manfred A1 - Rossaint, R. A1 - Tolba, R. T1 - A New Model for Blunt Liver Injuries in the Swine JF - European Surgical Research. 44 (2010), H. 2 Y1 - 2010 SN - 1421-9921 SP - 65 EP - 73 ER - TY - JOUR A1 - Goßmann, Matthias A1 - Frotscher, Ralf A1 - Linder, Peter A1 - Bayer, Robin A1 - Epple, U. A1 - Staat, Manfred A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard T1 - Mechano-pharmacological characterization of cardiomyocytes derived from human induced pluripotent stem cells JF - Cellular physiology and biochemistry N2 - Background/Aims: Common systems for the quantification of cellular contraction rely on animal-based models, complex experimental setups or indirect approaches. The herein presented CellDrum technology for testing mechanical tension of cellular monolayers and thin tissue constructs has the potential to scale-up mechanical testing towards medium-throughput analyses. Using hiPS-Cardiac Myocytes (hiPS-CMs) it represents a new perspective of drug testing and brings us closer to personalized drug medication. Methods: In the present study, monolayers of self-beating hiPS-CMs were grown on ultra-thin circular silicone membranes and deflect under the weight of the culture medium. Rhythmic contractions of the hiPS-CMs induced variations of the membrane deflection. The recorded contraction-relaxation-cycles were analyzed with respect to their amplitudes, durations, time integrals and frequencies. Besides unstimulated force and tensile stress, we investigated the effects of agonists and antagonists acting on Ca²⁺ channels (S-Bay K8644/verapamil) and Na⁺ channels (veratridine/lidocaine). Results: The measured data and simulations for pharmacologically unstimulated contraction resembled findings in native human heart tissue, while the pharmacological dose-response curves were highly accurate and consistent with reference data. Conclusion: We conclude that the combination of the CellDrum with hiPS-CMs offers a fast, facile and precise system for pharmacological, toxicological studies and offers new preclinical basic research potential. KW - Inotropic compounds KW - Pharmacology KW - Ion channels KW - CellDrum KW - Heart tissue culture KW - Induced pluripotent stem cells KW - Cardiac myocytes Y1 - 2016 U6 - http://dx.doi.org/10.1159/000443124 SN - 1421-9778 (Online) SN - 1015-8987 (Print) VL - 38 IS - 3 SP - 1182 EP - 1198 PB - Karger CY - Basel ER -