TY - CHAP A1 - Gogolin, C. A1 - Carvalho, R. A1 - Bung, Daniel Bernhard A1 - Matos, J. T1 - Experimental and numerical investigation of steady and unsteady flows in roughened channels with cross beams T2 - 35th IAHR world congress : 8.-13.9.2013, Chengdu, China Y1 - 2013 SP - Artikelkennnummer: A10837C PB - Tsinghua Univ. Press CY - Beijing ER - TY - CHAP A1 - Oertel, Mario A1 - Bung, Daniel Bernhard T1 - Comparison of 2D dam-break waves with VOF and SPH method T2 - Proceedings of the 35th IAHR world congress : 8.-13.9.2013, Chengdu, China Y1 - 2013 SP - Artikelkennnummer: A11113 PB - Tsinghua Univ. Press CY - Beijing ER - TY - CHAP A1 - Bung, Daniel Bernhard T1 - Air-water surface roughness in self-aerated stepped spillway flows T2 - 35th IAHR world congress : 8.-13.9.2013, Chengdu, China Y1 - 2013 SP - Artikelkennnummer: A11045 PB - Tsinghua Univ. Press CY - Beijing ER - TY - CHAP A1 - Becker, Jörg A1 - Eggert, Mathias A1 - Bruning, Dennis A1 - Saat, Jan T1 - Applicability of Business Process Model Analysis Approaches – A Case Study in Financial Services Consulting T2 - Wirtschaftsinformatik Proceedings 2013 Y1 - 2013 N1 - 11th International Conference on Wirtschaftsinformatik, 27th February – 01st March 2013, Leipzig, Germany SP - 1181 EP - 1195 ER - TY - CHAP A1 - Priede, Gareth A1 - Ferrein, Alexander T1 - Towards passive walking for the fully-actuated biped robot Nao T2 - Emerging trends in computing, informatics, systems sciences, and engineering. (Lecture notes in electrical engineering : vol. 151) N2 - Many biped robots deploy a form of gait that follows the zero moment point (ZMP) approach, that is, the robot is in a stable position at any point in time. This requires the robot to be fully actuated. While very stable, the draw-backs of this approach are a fairly slow gait and high energy consumption. An alternative approach is the so-called passive-dynamic walking, where the gait makes use of the inertia and dynamic stability of the robot. In this paper we describe our ongoing work of combining the principles of passive-dynamic walking on the fully-actuated biped robot Nao, which is also deployed for robotic soccer applications. We present a simple controller that allows the robot to stably rock sidewards, showing a closed limit-cycle. We discuss first results of superimposing a forward motion on the sidewards motion. Based on this we expect to endow the Nao with a fast, robust, and stable passive-dynamic walk on the fully-actuated Nao in the future. Y1 - 2013 SN - 978-1-4614-3557-0 ; 978-1-4614-3558-7 U6 - https://doi.org/10.1007/978-1-4614-3558-7_18 SP - 225 EP - 236 PB - Springer CY - New York, NY ER - TY - JOUR A1 - Buniatyan, V. A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Aroutiounian, V. M. A1 - Schöning, Michael Josef T1 - BaxSr1-x TiO3/pc-Si heterojunction JF - Armenian journal of physics Y1 - 2013 SN - 1829-1171 VL - 6 IS - 4 SP - 177 EP - 187 PB - National Academy of Sciences of Armenia CY - Yerevan ER - TY - JOUR A1 - Poghossian, Arshak A1 - Weil, M. A1 - Cherstvy, A. G. A1 - Schöning, Michael Josef T1 - Electrical monitoring of polyelectrolyte multilayer formation by means of capacitive field-effect devices JF - Analytical and bioanalytical chemistry N2 - The semiconductor field-effect platform represents a powerful tool for detecting the adsorption and binding of charged macromolecules with direct electrical readout. In this work, a capacitive electrolyte–insulator–semiconductor (EIS) field-effect sensor consisting of an Al-p-Si-SiO2 structure has been applied for real-time in situ electrical monitoring of the layer-by-layer formation of polyelectrolyte (PE) multilayers (PEM). The PEMs were deposited directly onto the SiO2 surface without any precursor layer or drying procedures. Anionic poly(sodium 4-styrene sulfonate) and cationic weak polyelectrolyte poly(allylamine hydrochloride) have been chosen as a model system. The effect of the ionic strength of the solution, polyelectrolyte concentration, number and polarity of the PE layers on the characteristics of the PEM-modified EIS sensors have been studied by means of capacitance–voltage and constant-capacitance methods. In addition, the thickness, surface morphology, roughness and wettabilityof the PE mono- and multilayers have been characterised by ellipsometry, atomic force microscopy and water contact-angle methods, respectively. To explain potential oscillations on the gate surface and signal behaviour of the capacitive field-effect EIS sensor modified with a PEM, a simplified electrostatic model that takes into account the reduced electrostatic screening of PE charges by mobile ions within the PEM has been proposed and discussed. Y1 - 2013 U6 - https://doi.org/10.1007/s00216-013-6951-9 SN - 1432-1130 ; 1618-2642 VL - 405 IS - 20 SP - 6425 EP - 6436 PB - Springer CY - Berlin ER - TY - JOUR A1 - Gräßl, Andreas A1 - Renz, Wolfgang A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Winter, Lukas A1 - Özerdem, Celal A1 - Rieger, Jan A1 - Kellmann, Peter A1 - Santoro, Davide A1 - Lindel, Tomasz D. A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Niendorf, Thoralf T1 - Modular 32-channel transceiver coil array for cardiac MRI at 7.0T JF - Magnetic Resonance in Medicine N2 - Purpose To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. Methods The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. Results Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. Conclusion The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T. Y1 - 2013 U6 - https://doi.org/10.1002/mrm.24903 SN - 1522-2594 VL - 72 IS - 1 SP - 276 EP - 290 PB - Wiley-Liss CY - New York ER - TY - CHAP A1 - Niemüller, Tim A1 - Lakemeyer, Gerhard A1 - Ferrein, Alexander T1 - Aspects of integrating diverse software into robotic systems extended abstract T2 - ICRA 2013 - 8th Workshop on Software Development and Integration in Robotics (SDIR), Karlsruhe, Germany Y1 - 2013 SP - 1 EP - 2 ER - TY - CHAP A1 - Fabo, Sabine ED - Kacunko, Slavko T1 - Portrait of the artist as a spoilsport : Marcel Odenbach's concept of detachment T2 - Take it or leave it : Marcel Odenbach - anthology of texts and videos. - (eva - edition video art ; 2) Y1 - 2013 SN - 978-3-8325-3386-1 SP - 11 EP - 29 PB - Logos CY - Berlin ER - TY - GEN A1 - Waiczies, Helmar A1 - Kühne, André A1 - Winter, Lukas A1 - Frauenrath, Tobias A1 - Hoffmann, Werner A1 - Ittermann, Bernd A1 - Waiczies, Sonia A1 - Niendorf, Thoralf T1 - Towards theranostics of rheumatoid arthritis: 1H/19F imaging of non-steroidal anti-inflammatory drugs in hand and wrist at 7 Tesla T2 - 2013 ISMRM Annual Meeting Proceedings N2 - We have developed a double-tuned ¹H/¹⁹F birdcage resonator dedicated for hand and wrist imaging at 7 T to locally image non-steroidal anti-inflammatory drugs (NSAID) such as 2-{[3-(Trifluoromethyl) phenyl]amino}benzoic acid. The preliminary in vivo images acquired by the double-tuned ¹H/¹⁹F birdcage resonator demonstrate the feasibility for ¹H/¹⁹F hand- and wrist-imaging at 7 T. While the diagnostic quality of the coil needs to be assessed in patients with inflammatory rheumatoid disease, first ¹⁹F images of the NSAID are encouraging, and point towards the prospect of applying ¹⁹F-MRI to visualize and quantify the concentration of therapeutically-active compound at the sites of inflammation. Y1 - 2013 SN - 1545-4428 N1 - ISMRM 21st Annual Meeting & Exhibition, 20-26 April 2013, Salt Lake City, Utah, USA ER - TY - JOUR A1 - Kramer, Friederike A1 - Halamkova, Lenka A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Katz, Evgeny A1 - Halamek, Jan T1 - Biocatalytic analysis of biomarkers for forensic identification of ethnicity between Caucasian and African American JF - The analyst. August 2013 Y1 - 2013 SN - 1364-5528 (E-Journal); 0003-2654 (Print) VL - Vol. 138 SP - 6251 EP - 6257 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Bäcker, Matthias A1 - Rakowski, D. A1 - Poghossian, Arshak A1 - Biselli, Manfred A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis JF - Journal of Biotechnology N2 - A microfluidic chip integrating amperometric enzyme sensors for the detection of glucose, glutamate and glutamine in cell-culture fermentation processes has been developed. The enzymes glucose oxidase, glutamate oxidase and glutaminase were immobilized by means of cross-linking with glutaraldehyde on platinum thin-film electrodes integrated within a microfluidic channel. The biosensor chip was coupled to a flow-injection analysis system for electrochemical characterization of the sensors. The sensors have been characterized in terms of sensitivity, linear working range and detection limit. The sensitivity evaluated from the respective peak areas was 1.47, 3.68 and 0.28 μAs/mM for the glucose, glutamate and glutamine sensor, respectively. The calibration curves were linear up to a concentration of 20 mM glucose and glutamine and up to 10 mM for glutamate. The lower detection limit amounted to be 0.05 mM for the glucose and glutamate sensor, respectively, and 0.1 mM for the glutamine sensor. Experiments in cell-culture medium have demonstrated a good correlation between the glutamate, glutamine and glucose concentrations measured with the chip-based biosensors in a differential-mode and the commercially available instrumentation. The obtained results demonstrate the feasibility of the realized microfluidic biosensor chip for monitoring of bioprocesses. Y1 - 2013 U6 - https://doi.org/10.1016/j.jbiotec.2012.03.014 SN - 0168-1656 VL - 163 IS - 4 SP - 371 EP - 376 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Beverungen, Daniel A1 - Eggert, Mathias A1 - Voigt, Matthias A1 - Rosemann, Michael T1 - Augmenting Analytical CRM Strategies with Social BI JF - International Journal of Business Intelligence Research (IJBIR) Y1 - 2013 U6 - https://doi.org/10.4018/ijbir.2013070103 SN - 1947-3591 VL - 4 IS - 3 SP - 32 EP - 49 PB - IGI Global CY - Hershey ER - TY - JOUR A1 - Wiegand, Sandra A1 - Voigt, Birgit A1 - Albrecht, Dirk A1 - Bongaerts, Johannes A1 - Evers, Stefan A1 - Hecker, Michael A1 - Daniel, Rolf A1 - Liesegang, Heiko T1 - Fermentation stage-dependent adaptations of Bacillus licheniformis during enzyme production JF - Microbial Cell Factories Y1 - 2013 U6 - https://doi.org/10.1186/1475-2859-12-120 SN - 1475-2859 VL - 12 SP - 120 PB - Biomed Central CY - London ER - TY - JOUR A1 - Buniatyan, V. A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Aroutiounian, V. M. A1 - Schöning, Michael Josef T1 - BaxSr1-x TiO3/pc-Si heterojunction capacitance JF - Armenian journal of physics Y1 - 2013 SN - 1829-1171 VL - 6 IS - 4 SP - 188 EP - 197 PB - National Academy of Sciences of Armenia CY - Yerevan ER - TY - JOUR A1 - Kuhnert, Marie-Therese A1 - Bialonski, Stephan A1 - Noenning, Nina A1 - Mai, Heinke A1 - Hinrichs, Hermann A1 - Helmstaedter, Christoph A1 - Lehnertz, Klaus T1 - Incidental and intentional learning of verbal episodic material differentially modifies functional brain networks JF - Plos one N2 - Learning- and memory-related processes are thought to result from dynamic interactions in large-scale brain networks that include lateral and mesial structures of the temporal lobes. We investigate the impact of incidental and intentional learning of verbal episodic material on functional brain networks that we derive from scalp-EEG recorded continuously from 33 subjects during a neuropsychological test schedule. Analyzing the networks' global statistical properties we observe that intentional but not incidental learning leads to a significantly increased clustering coefficient, and the average shortest path length remains unaffected. Moreover, network modifications correlate with subsequent recall performance: the more pronounced the modifications of the clustering coefficient, the higher the recall performance. Our findings provide novel insights into the relationship between topological aspects of functional brain networks and higher cognitive functions. Y1 - 2013 U6 - https://doi.org/10.1371/journal.pone.0080273 VL - 8 IS - 11 PB - PLOS CY - San Francisco ER - TY - CHAP A1 - Savitskaya, Irina S. A1 - Kistaubayeva, Aida S. A1 - Akimbekov, Nuraly S. A1 - Digel, Ilya A1 - Zhubanova, Azhar A. T1 - Performance of Bio-Composite Carbonized Materials in Probiotic Applications T2 - World Academy of Science, Engineering and Technology International Journal of Biotechnology and Bioengineering Y1 - 2013 VL - 7 IS - 7 SP - 685 EP - 689 ER - TY - CHAP A1 - Dachwald, Bernd A1 - Ulamec, Stephan A1 - Biele, Jens T1 - Clean in situ subsurface exploration of icy environments in the solar system T2 - Habitability of other planets and satellites. - (Cellular origin, life in extreme habitats and astrobiology ; 28) N2 - "To assess the habitability of the icy environments in the solar system, for example, on Mars, Europa, and Enceladus, the scientific analysis of material embedded in or underneath their ice layers is very important. We consider self-steering robotic ice melting probes to be the best method to cleanly access these environments, that is, in compliance with planetary protection standards. The required technologies are currently developed and tested." Y1 - 2013 SN - 978-94-007-6545-0 (Druckausgabe) SN - 978-94-007-6546-7 (E-Book) SP - 367 EP - 397 PB - Springer CY - Dordrecht ER - TY - PAT A1 - Al-Kaidy, Huschyar A1 - Tippkötter, Nils A1 - Ulber, Roland T1 - A system and a method for the implementation of chemical, biological or physical reactions [Europäische Patentanmeldung] N2 - The invention relates to a system for the implementation of chemical, biological or physical reactions, consisting of - one or more magnetic micro-reactors, each comprising a shell made of hydrophobic magnetic nanoparticles encapsulating an aqueous core, - a plane platform comprising a surface to receive the micro-reactors, - a source that generates a magnetic field above or underneath the platform for manipulating the one or more hydrophobic magnetic micro-reactors, or for moving them along the surface of the platform from one position to another position, characterized in that the aqueous core of the one or more magnetic micro-reactors contains a reaction solution or buffer, and wherein the magnetic field generated by the source correlates to a defined position on the surface of the platform. Y1 - 2013 PB - Europäisches Patentamt CY - Den Hague ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - An Upper Bound Algorithm for Limit and Shakedown Analysis of Bounded Linearly Kinematic Hardening Structures JF - Limit State of Materials and Structures : Direct Methods 2. Saxcé, Géry de (Hrsg.) Y1 - 2013 SN - 978-94-007-5424-9 SP - 71 EP - 87 PB - Springer CY - Dordrecht ER - TY - JOUR A1 - Schusser, Sebastian A1 - Leinhos, Marcel A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers JF - Physica Status Solidi (A) N2 - Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution. Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200941 SN - 1521-396X ; 0031-8965 VL - 210 IS - 5 SP - 905 EP - 910 PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Becker, Jörg A1 - Eggert, Mathias A1 - Saat, Jan A1 - Dirding, Philipp T1 - The Influence of Regulation on Data Warehouse Engineering – Investigating an IT Consulting Case in the Financial Service Industry T2 - Proceedings of the Nineteenth Americas Conference on Information Systems, Chicago, Illinois, August 15-17, 2013. Y1 - 2013 SP - 1 EP - 8 ER - TY - JOUR A1 - Akimbekov, Nuraly S. A1 - Digel, Ilya A1 - Savitkaya, I.S. A1 - Zhubanova, A.A. A1 - Tastambek, K.T. T1 - Investigations of LPS endotoxin elimination in the flowing column conditions with the sorbent on the basis of carbonized rice husk JF - KazNU Bulletin. Biology series Y1 - 2013 SN - 1563-0218 N1 - Original in russischer Sprache VL - 57 IS - 1 SP - 124 EP - 127 ER -