TY - JOUR A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef T1 - Real-time detection of CO by eukaryotic cells JF - Procedia Engineering N2 - In this contribution, we focus on the detection of toxic gases with living eukaryotic cells. A cell-based gas sensor system, able to measure the effects of direct exposure of gases to cells in real-time, was set up. Impedance data as well as oxygen consumption of Chinese hamster lung fibroblast cells (V79) were analysed upon exposure to carbon monoxide (CO). The CO (diluted in wet synthetic air) affects the cell respiration as indicated by an attenuated respiration signal after the CO exposure as well as an instant increase of the capacitive part of the impedance signal during the gas exposure. Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 17 EP - 20 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Sponagel, Stefan A1 - Baroud, Gamal A1 - Falk, R. A1 - Crookshank, M. T1 - Experimental and theoretical investigation of directional permeability of human vertebral cancellous bone for cement infiltration. G. Baroud, R. Falk, M. Crookshank, S. Sponagel, T. Steffen JF - Journal of Biomechanics. 37 (2004), H. 2 Y1 - 2004 SN - 0021-9290 SP - 189 EP - 196 ER - TY - JOUR A1 - Bode, Jürgen A1 - Bartsch, Jörg W. A1 - Boulikas, Toulikas A1 - Iber, Michaela A1 - Mielke, Christian A1 - Schübeler, Dirk A1 - Seibler, Jost A1 - Benham, Craig T1 - Transcription-promoting genomic sites in mammalia: their elucidation and architectural principles JF - Gene therapy & molecular biology Y1 - 1998 SN - 1529-9120 VL - 1 IS - 1 SP - 1 EP - 29 ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schaffrath, Sophie A1 - Coppe, Thomas A1 - Rufi, Frederic A1 - Schöning, Michael Josef T1 - Development of an electrolyte-insulator-semiconductor (EIS) based capacitive heavy metal sensor for the detection of Pb2+ und Cd2+ ions JF - Physica status solidi (a) : applications and material science N2 - Chalcogenide glass materials as membranes for potentiometric sensors for chemical analysis in solutions have been studied since more than 20 years. In this work, an electrolyte–insulator–semiconductor structure was combined with chalcogenide glass membranes prepared by means of the pulsed laser deposition technique. Depending on the membrane composition a selectivity to different ions (Cd2+ and Pb2+) is achieved. The different sensor membranes have been physically characterised using microscopy, ellipsometry, profilometry, atomic force microscopy (AFM), scanning electron microscopy (SEM) and Rutherford backscattering spectrometry (RBS). The electrochemical behaviour has been investigated via capacitance/voltage (C/V) and constant capacitance (ConCap) measurements and results in a Cd2+ sensitivity of 23.1 ± 0.6 mV per decade in a linear range from 7 × 10−6 to 10−2 mol/l and 24.4 ± 0.5 mV per decade in a linear range from 5 × 10−6 to 10−2 mol/l for Pb2+, respectively. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983306 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 930 EP - 934 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Digel, Ilya A1 - Wehlitz, V. A1 - Kayser, Peter A1 - Figiel-Lange, A. A1 - Bassam, Rasha A1 - Rundstedt, F. von T1 - Suspension depletion approach for exemption of infected Solanum jasminoides cells from pospiviroids JF - Plant Pathology N2 - Despite numerous studies, viroid elimination from infected plants remains a very challenging task. This study introduces for the first time a novel ‘suspension depletion’ approach for exemption of Solanum jasminoides plants from viroids. The proposed method implies initial establishment of suspension cultures of the infected plant cells. The suspended cells were then physically treated (mild thermotherapy, 33 °C), which presumably delayed the replication of the viroid. The viroid concentration in the treated biomass was monitored weekly using pospiviroid-specific PCR. After 10–12 weeks of continuous treatment, a sufficient decrease in viroid concentration was observed such that the infection became undetectable by PCR. The treated single cells then gave rise to microcolonies on a solid culture medium and the obtained viroid-negative clones were further promoted to regenerate into viroid-free plants. Three years of accumulated experimental data suggests feasibility, broad applicability, and good efficacy of the proposed approach. Y1 - 2018 U6 - https://doi.org/10.1111/ppa.12750 SN - 1365-3059 VL - 67 IS - 2 SP - 358 EP - 365 PB - Wiley CY - Oxford ER - TY - JOUR A1 - Staat, Manfred A1 - Baroud, Gamal A1 - Topcu, M. A1 - Sponagel, Stefan T1 - Soft Materials in Technology and Biology – Characteristics, Properties, and Parameter Identification JF - Bioengineering in Cell and Tissue Research / Artmann, Gerhard M. ; Chien, Shu (Eds.) Y1 - 2008 SN - 978-3-540-75408-4 SP - 253 EP - 315 PB - Springer CY - Berlin ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Başkurt, Oǧuz Kerim A1 - Pekcetin, C. A1 - Kandemir, F. T1 - Leukocyte activation, oxidant stress and red blood cell properties after acute, exhausting exercise in rats. Temiz, A.; Baskurt, O. K., Pekcetin, C.; Kandemir, F.; Güre, A. JF - Clinical Hemorheology and Microcirculation. 22 (2000), H. 4 Y1 - 2000 SN - 1386-0291 SP - 253 EP - 259 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Yalcin, Ozlem A1 - Resmi, Halil A1 - Başkurt, Oǧuz Kerim T1 - Can white blood cell activation be one of the major factors that affect hemorheological parameters during and after exercise? JF - Clinical Hemorheology and Microcirculation. 26 (2002), H. 3 Y1 - 2002 SN - 1386-0291 N1 - = The 11th European Symposium on Clinical Hemorheology, Rouen, France, 19-22 September 2000 SP - 189 EP - 193 ER - TY - JOUR A1 - Gerhards, Michael A1 - Belloum, Adam A1 - Berretz, Frank A1 - Sander, Volker A1 - Skorupa, Sascha T1 - A history-tracing XML-based provenance framework for workflows JF - The 5th Workshop on Workflows in Support of Large-Scale Science N2 - The importance of validating and reproducing the outcome of computational processes is fundamental to many application domains. Assuring the provenance of workflows will likely become even more important with respect to the incorporation of human tasks to standard workflows by emerging standards such as WS-HumanTask. This paper addresses this trend by an actor-based workflow approach that actively support provenance. It proposes a framework to track and store provenance information automatically that applies for various workflow management systems. In particular, the introduced provenance framework supports the documentation of workflows in a legally binding way. The authors therefore use the concept of layered XML documents, i.e. history-tracing XML. Furthermore, the proposed provenance framework enables the executors (actors) of a particular workflow task to attest their operations and the associated results by integrating digital XML signatures. KW - workflow KW - provenance KW - framework KW - containers KW - humans KW - synchronization KW - libraries KW - history KW - concrete KW - XML Y1 - 2010 SN - 978-1-4244-8989-3 U6 - https://doi.org/10.1109/WORKS.2010.5671873 N1 - The 5th Workshop on Workflows in Support of Large-Scale Science, 14 Nov. 2010, New Orleans, USA PB - IEEE CY - New York ER - TY - JOUR A1 - Kern, Alexander A1 - Frentzel, Ralf A1 - Behrens, Jörg T1 - Simulation of the transient voltages in the auxiliary power network of a large power plant in case of a direct lightning strike to the high-voltage overhead transmission line N2 - Large power plants can be endangered by lightning strikes with possible consequences regarding their safety and availability. A special scenario is a lightning strike to the HV overhead transmission line close to the power plant's connection to the power grid. If then additionally a so-called shielding failure of the overhead ground wire on top of the overhead transmission line is assumed, i.e. the lightning strikes directly into a phase conductor, this is an extreme electromagnetic disturbance. The paper deals with the numerical simulation of such a lightning strike and the consequences on the components of the power plant's auxiliary power network connected to different voltage levels. KW - power generation KW - surges KW - conductors KW - arresters KW - power transmission lines KW - lightning Y1 - 2010 SN - 978-88-905519-0-1 U6 - https://doi.org/10.1109/ICLP.2010.7845756 N1 - 2010 30th International Conference on Lightning Protection (ICLP), 13-17 Sept. 2010, Cagliari, Italy SP - 749-1 EP - 749-7 PB - IEEE CY - New York ER - TY - JOUR A1 - Bouquegneau, Christian A1 - Kern, Alexander A1 - Rousseau, Alain T1 - Lightning safety guidelines N2 - This paper introduces lightning to the layman, noting the right behaviour in front of thunderstorms as well as protective measures against lightning. It also contributes to the prevention of lightning injuries and damages. This report was prepared by the authors inside the AHG1 Group for IEC TC81 (Lightning Protection). Y1 - 2010 N1 - Ground´2010 & 4th LPE, International Conference on Grounding and Earthing & 4th International Conference on Lightning Physics and Effects, Salvador - Brazil, November, 2010 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Baroud, Gamal A1 - Falk, R. A1 - Crookshank, M. T1 - Corrigendum to “Experimental and theoretical investigation of directional permeability of human vertebral cancellous bone for cement infiltration”. Baroud, G.; Falk, R.; Crookshank, M.; Sponagel, S.; Steffen, T. JF - Journal of Biomechanics. 37 (2004), H. 2 Y1 - 2004 SN - 0021-9290 SP - 1802 ER - TY - JOUR A1 - Weber, Tobias A1 - Arent, Jan-Christoph A1 - Steffen, Lucas A1 - Balvers, Johannes Mattheus A1 - Duhovic, Miro T1 - Thermal optimization of composite autoclave molds using the shift factor approach for boundary condition estimation JF - Journal of Composite Materials Y1 - 2017 U6 - https://doi.org/10.1177/0021998317699868 SN - 1530-793X VL - 51 IS - 12 SP - 1753 EP - 1767 PB - Sage CY - London ER - TY - JOUR A1 - Kern, Alexander A1 - Klöters, Georg A1 - Pferdemenges, Jörg T1 - Optimised protection against lightning for the signalling and safety systems of level crossings on non-electrified railway lines JF - RTR : European Rail Technology Review Y1 - 2010 SN - 0079-9548 VL - 50 IS - 2 PB - DVV Media Group CY - Hamburg ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Başkurt, Oǧuz Kerim A1 - Edremitlioglu, M. T1 - In vitro effects of in vivo activated leukocytes on red blood cell filterability and lipid peroxidation. Baskurt, O.K.; Edremitlioglu, M.; Temiz, A. JF - Clinical Hemorheology. 14 (1994), H. 4 Y1 - 1994 SP - 591 EP - 596 ER - TY - JOUR A1 - Sponagel, Stefan A1 - Baroud, Gamal A1 - Steffen, T. A1 - Wu, J. T1 - Parameter identification for cement infiltration of osteoporotic bone JF - Poromechanics II : Proceedings of the Second Biot Conference on Poromechanics Grenoble, France 26 - 28 August 2002 / ed. by J.-L. Auriault ... Y1 - 2002 SN - 90-5809-394-8 SP - 55 EP - 58 PB - Balkema CY - Lisse [u.a.] ER - TY - JOUR A1 - Kern, Alexander A1 - Schelthoff, Christof A1 - Mathieu, Moritz T1 - Probability of lightning strikes to air-terminations of structures using the electro-geometrical model theory and the statistics of lightning current parameters N2 - Planning the air-terminations for a structure to be protected the use of the rolling-sphere method (electro-geometrical model) is the best way from the physics of lightning point-of-view. Therefore, international standards prefer this method. However, using the rolling-sphere method only results in possible point-of-strikes on a structure without giving information about the probability of strikes at the individual points compared to others. KW - atmospheric modeling KW - probability distribution KW - lightning protection KW - standards KW - planning Y1 - 2010 SN - 978-88-905519-0-1 U6 - https://doi.org/10.1109/ICLP.2010.7845757 N1 - 2010 30th International Conference on Lightning Protection (ICLP), 13-17 Sept. 2010, Cagliari, Italy SP - 750-1 EP - 750-8 PB - IEEE CY - New York ER - TY - JOUR A1 - Naujokat, Anke T1 - Ut rhetorica architectura – Leon Battista Alberti´s Technique of Architectural Collage / Leon Battista Albertis architektonische Collagetechnik JF - Candide : journal for architectural knowledge N2 - Leon Battista Alberti, probably the most innovative architect of early Renaissance Italy, has always fascinated scholars by virtue of the striking interpenetration of theory and practice manifest in his work. As an architect, Alberti was an autodidact. Without the benefit of the formative influence of a master or design education, the roots of his conception of architecture lie in his intellectual formation through humanistic rhetoric. The present study demonstrates with reference to a specific project — the Tempietto of the Holy Sepulchre in Florence — how Alberti’s humanist approach conditioned his method of architectural design. Y1 - 2010 SN - 1869-6465 VL - 2 SP - 73 EP - 100 PB - RWTH Aachen CY - Aachen ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Başkurt, Oǧuz Kerim A1 - Meiselman, H. J. T1 - Effect of superoxide anions on red blood cell rheologic properties. Baskurt, O. K.; Temiz, A.; Meiselman, H. J. JF - Free Radical Biology and Medicine. 24 (1998), H. 1 Y1 - 1998 SN - 0891-5849 SP - 102 EP - 110 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Başkurt, Oǧuz Kerim A1 - Meiselman, H. J. T1 - Red blood cell aggregation in experimental sepsis . Baskurt, O. K.; Temiz, A.; Meiselman, H. J. JF - Journal of Laboratory and Clinical Medicine. 130 (1997), H. 2 Y1 - 1997 SN - 0022-2143 SP - 183 EP - 190 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Başkurt, Oǧuz Kerim A1 - Edremitlioglu, M. T1 - Effect of erythrocyte deformability on myocardial hematocrit gradient. Baskurt, O.K.; Edremitlioglu, M.; Temiz, A. JF - American Journal of Physiology: Heart and Circulatory Physiology. 268 (1995), H. 1 Y1 - 1995 SN - 0363-6135 SP - 260 EP - 264 ER - TY - JOUR A1 - Wagner, Torsten A1 - Miyamoto, Ko-ichiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Novel combination of digital light processing (DLP) and light-addressable potentiometric sensors (LAPS) for flexible chemical imaging JF - Procedia Engineering N2 - Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach of read out in a light-addressable potentiometric sensor (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device which allows fast and flexible generation of light patterns. With the help of these light patterns the sensor surface of the LAPS device can be read out sequentially in a raster like scheme (scanning LAPS). The DLP approach has several advantages compared to conventional scanning LAPS set-ups, e.g., the spot size, the shape and the intensity of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of measurement. Y1 - 2010 U6 - https://doi.org/10.1016/j.proeng.2010.09.161 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 520 EP - 523 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Pedraza, A. M. A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Label-free DNA hybridization and denaturation detection by means of field-effect nanoplate SOI capacitors functionalized with gold nanoparticles JF - Procedia Engineering N2 - A new approach for a label-free electrical detection of DNA hybridization and denaturation using an array of individually addressable field-effect nanoplate SOI (silicon-on-insulator) capacitors functionalized with gold nanoparticles is presented. By using a constant-capacitance measuring setup in a differential mode, signal changes of ∼110 mV and ∼70 mV have been registered after the DNA hybridization and denaturation events, respectively. Y1 - 2010 U6 - https://doi.org/10.1016/j.proeng.2010.09.259 SN - 1877-7058 N1 - Eurosensor XXIV Conference, 5-8 September 2010, Linz, Austria VL - 5 SP - 918 EP - 921 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Berretz, Frank A1 - Skorupa, Sascha A1 - Sander, Volker A1 - Belloum, Adam T1 - Towards an actor-driven workflow management system for grids JF - Proceedings of 2010 International Symposium on Collaborative Technologies and Systems N2 - Currently, most workflow management systems in Grid environments provide push-oriented job distribution strategies, where jobs are explicitly delegated to resources. In those scenarios the dedicated resources execute submitted jobs according to the request of a workflow engine or Grid wide scheduler. This approach has various limitations, particularly if human interactions should be integrated in workflow execution. To support human interactions with the benefit of enabling inter organizational computation and community approaches, this poster paper proposes the idea of a pull-based task distribution strategy. Here, heterogeneous resources, including human interaction, should actively select tasks for execution from a central repository. This leads to special demands regarding security issues like access control. In the established push-based job execution the resources are responsible for granting access to workflows and job initiators. In general this is done by access control lists, where users are explicitly mapped to local accounts according to their policies. In the pull-based approach the resources actively apply for job executions by sending requests to a central task repository. This means that every resource has to be able to authenticate against the repository to be authorized for task execution. In other words the authorization is relocated from the resources to the repository. The poster paper introduces current work regarding to the mentioned security aspects in the pull-based approach within the scope of the project “HiX4AGWS”. KW - scheduling KW - engines KW - resource management KW - grid computing KW - access control KW - distribution strategy KW - authorization KW - security KW - humans KW - workflow management software Y1 - 2010 SN - 978-1-4244-6619-1 U6 - https://doi.org/10.1109/CTS.2010.5478458 N1 - 2010 International Symposium on Collaborative Technologies and Systems, 17-21 May 2010, Chicago, IL, USA SP - 611 EP - 616 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Ziemons, Karl A1 - Heinrichs, U. A1 - Streun, M. A1 - Pietrzyk, Uwe T1 - Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. Y1 - 2004 SN - 1082-3654 SP - 3053 EP - 3056 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chatziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, Uwe T1 - Investigation of different MicroCT scanner configurations by GEANT4 simulations JF - IEEE Transactions on Nuclear Science N2 - This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2005 SN - 0018-9499 VL - 52 IS - 1 SP - 188 EP - 192 ER - TY - JOUR A1 - Blome, Hans-Joachim A1 - Chicone, Carmen A1 - Hehl, Friedrich W. A1 - Mashhoon, Bahram T1 - Nonlocal modification of Newtonian gravity JF - Physical Review D N2 - The Newtonian regime of a recent nonlocal extension of general relativity is investigated. Nonlocality is introduced via a scalar “constitutive” kernel in a special case of the translational gauge theory of gravitation, namely, the teleparallel equivalent of general relativity. In this theory, the nonlocal aspect of gravity simulates dark matter. A nonlocal and nonlinear generalization of Poisson’s equation of Newtonian gravitation is presented. The implications of nonlocality for the gravitational physics in the solar system are briefly studied. Y1 - 2010 U6 - https://doi.org/10.1103/PhysRevD.81.065020 SN - 0556-2821 VL - 81 IS - 6 EP - 065020 PB - American Physical Society CY - Melville, NY ER - TY - JOUR A1 - Ziemons, Karl A1 - Bruyndonckx, P. A1 - Perez, J. M. A1 - Pietrzyk, Uwe A1 - Rato, P. A1 - Tavernier, S. T1 - Beyond ClearPET: Next Aims JF - 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro Symposium Proceedings ISBI 2008 N2 - The CRYSTAL CLEAR collaboration, in short CCC, is a consortium of 12 academic institutions, mainly from Europe, joining efforts in the area of developing instrumentation for nuclear medicine and medical imaging. In the framework of the CCC a high performance small animal PET system, called ClearPET, was developed by using new technologies in electronics and crystals in a phoswich arrangement combining two types of lutetium- based scintillator materials: LSO:Ce and LuYAP:Ce. Our next aim will be the development of hybrid image systems. Hybrid MR-PET imaging has many unique advantages for brain research. This has sparked a new research line within CCC for the development of novel MR-PET compatible technologies. MRI is not as sensitive as PET but PET has poorer spatial resolution than MRI. Two major advantages of PET are sensitivity and its ability to acquire metabolic information. To assess these innovations, the development of a 9.4T hybrid animal MR-PET scanner is proposed based on an existing 9.4T MR scanner that will be adapted to enable simultaneous acquisition of MR and PET data using cutting- edge technology for both MR and PET. Y1 - 2008 SN - 978-1-4244-2003-2 SP - 1421 EP - 1424 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chaziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, Uwe T1 - Investigation of different microCT scanner configurations by GEANT4 simulations JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - This study has been performed to design the combination of the new ClearPET TM (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal Positron Emission Tomography (PET) system, with a microComputed Tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2004 SN - 1082-3654 SP - 2989 EP - 2993 ER - TY - JOUR A1 - Schmitt, Robert A1 - Scholl, Ingrid A1 - Cai, Yu A1 - Xia, Ji A1 - Dziwoki, Paul A1 - Harding, Martin A1 - Pavim, Alberto T1 - Machine vision system for inline inspection in carbide insert production JF - Proceedings of the 36th International MATADOR Conference N2 - In steps of the production chain of carbide inserts, such as unloading or packaging, the conformity test of the insert type is done manually, which causes a statistic increase of errors due to monotony and fatigue of the worker and the wide variety of the insert types. A machine vision system is introduced that captures digital frames of the inserts in the production line, analyses inspects automatically and measures four quality features: coating colour, edge radius, plate shape and chip-former geometry. This new method has been tested on several inserts of different types and has shown that the prevalent insert types can be inspected and robustly classified in real production environment and therefore improves the manufacturing automation. Y1 - 2010 SN - 978-1-84996-431-9 U6 - https://doi.org/10.1007/978-1-84996-432-6_77 N1 - 36th MATADOR Conference, University of Manchester, July 2010 SP - 339 EP - 342 PB - Springer CY - Berlin ER - TY - JOUR A1 - Wagner, Torsten A1 - Werner, Frederik A1 - Miyamoto, Ko-ichiro A1 - Ackermann, Hans-Josef A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - FPGA-based LAPS device for the flexible design of sensing sites on functional interfaces JF - Physica Status Solidi (A) N2 - The development of new interfaces for (bio-)chemical sensors requires comprehensive analyses and testing. The light-addressable potentiometric sensor (LAPS) can be used as a platform to investigate the sensitivity of a newly developed interface towards (bio-)chemical agents. LAPS measurements are spatially resolved by utilisation of focused light beams to define individual measurement spots. In this work, a new digitally modulated LAPS set-up based on an FPGA design will be introduced to increase the number of measurement spots, to shorten the measurement time and to improve the measurement accuracy. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983320 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 844 EP - 849 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Berretz, Frank A1 - Skorupa, Sascha A1 - Sander, Volker A1 - Belloum, Adam A1 - Bubak, Marian T1 - Actor-Driven Workflow Execution in Distributed Environments JF - Euro-Par 2010 Parallel Processing Workshops : HeteroPAR, HPCC, HiBB, CoreGrid, UCHPC, HPCF, PROPER, CCPI, VHPC ; Ischia, Italy, August 31 - September 3, 2010 ; revised selected papers / Mario R. Guarracino ... (eds.) Y1 - 2011 SN - 978-3-642-21877-4 N1 - Lecture Notes in Computer Science ; 6586 SP - 287 EP - 294 PB - Springer CY - Berlin ER - TY - JOUR A1 - Gerhards, M. A1 - Skorupa, Sascha A1 - Sander, Volker A1 - Pfeiffer, P. A1 - Belloum, Adam T1 - Towards a security framework for a WS-HumanTask processor JF - 7th International Conference on Network and Service Management (CNSM), 2011 Paris Y1 - 2011 SN - 978-3-901882-44-9 SP - 1 EP - 5 PB - IEEE CY - New York ER - TY - JOUR A1 - Bernau, C. R. A1 - Knödler, Matthias A1 - Emonts, Jessica A1 - Jäpel, Ronald Colin A1 - Buyel, Johannes Felix T1 - The use of predictive models to develop chromatography-based purification processes JF - Frontiers in Bioengineering and Biotechnology N2 - Chromatography is the workhorse of biopharmaceutical downstream processing because it can selectively enrich a target product while removing impurities from complex feed streams. This is achieved by exploiting differences in molecular properties, such as size, charge and hydrophobicity (alone or in different combinations). Accordingly, many parameters must be tested during process development in order to maximize product purity and recovery, including resin and ligand types, conductivity, pH, gradient profiles, and the sequence of separation operations. The number of possible experimental conditions quickly becomes unmanageable. Although the range of suitable conditions can be narrowed based on experience, the time and cost of the work remain high even when using high-throughput laboratory automation. In contrast, chromatography modeling using inexpensive, parallelized computer hardware can provide expert knowledge, predicting conditions that achieve high purity and efficient recovery. The prediction of suitable conditions in silico reduces the number of empirical tests required and provides in-depth process understanding, which is recommended by regulatory authorities. In this article, we discuss the benefits and specific challenges of chromatography modeling. We describe the experimental characterization of chromatography devices and settings prior to modeling, such as the determination of column porosity. We also consider the challenges that must be overcome when models are set up and calibrated, including the cross-validation and verification of data-driven and hybrid (combined data-driven and mechanistic) models. This review will therefore support researchers intending to establish a chromatography modeling workflow in their laboratory. KW - biopharmaceutical production process KW - Data-driven models KW - downstream processing design KW - experiment quality KW - hybrid model validation Y1 - 2022 U6 - https://doi.org/10.3389/fbioe.2022.1009102 SN - 2296-4185 (online-ressource) IS - 10 PB - Frontiers Media CY - Lausanne ER - TY - JOUR A1 - Fredebeul-Krein, Markus A1 - Knoben, Werner T1 - Long term risk sharing contracts as an approach to establish public–private partnerships for investment into next generation access networks JF - Telecommunications Policy N2 - This paper develops an investment/pricing model for the deployment of basic broadband networks which, along with other applications, is applicable to public–private partnership projects. In particular, a new investment model is suggested to be used for finance deployment over a longer term by enabling both private and public investors to participate in the roll-out of next generation access (NGA) infrastructure. This so-called “long-term risk sharing concept” has several notable benefits compared with the traditional regulatory approach. Above all, the model enables both private operators and public authorities to share the risk of investing in NGA infrastructure. Thus the model offers a way for public authorities to achieve a timely and countrywide roll-out of NGA networks, including in areas where NGA investment would otherwise not occur. Y1 - 2010 U6 - https://doi.org/10.1016/j.telpol.2010.07.011 SN - 0308-5961 N1 - Part of special issue "Public–private interplay in next generation communications" VL - 34 IS - 9 SP - 528 EP - 539 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Gerhards, M. A1 - Skorupa, Sascha A1 - Sander, Volker A1 - Belloum, Adam A1 - Vesunin, D. A1 - Benabdelkader, A. T1 - HisT/PLIER : A Two-Fold Provenance Approach for Grid-Enabled Scientific Workflows Using WS-VLAM JF - 12th IEEE/ACM International Conference on Grid Computing (GRID), 2011 Y1 - 2011 U6 - https://doi.org/10.1109/Grid.2011.39 SP - 224 EP - 225 PB - IEEE CY - New York ER - TY - JOUR A1 - Emonts, Jessica A1 - Buyel, Johannes Felix T1 - An overview of descriptors to capture protein properties – Tools and perspectives in the context of QSAR modeling JF - Computational and Structural Biotechnology Journal N2 - Proteins are important ingredients in food and feed, they are the active components of many pharmaceutical products, and they are necessary, in the form of enzymes, for the success of many technical processes. However, production can be challenging, especially when using heterologous host cells such as bacteria to express and assemble recombinant mammalian proteins. The manufacturability of proteins can be hindered by low solubility, a tendency to aggregate, or inefficient purification. Tools such as in silico protein engineering and models that predict separation criteria can overcome these issues but usually require the complex shape and surface properties of proteins to be represented by a small number of quantitative numeric values known as descriptors, as similarly used to capture the features of small molecules. Here, we review the current status of protein descriptors, especially for application in quantitative structure activity relationship (QSAR) models. First, we describe the complexity of proteins and the properties that descriptors must accommodate. Then we introduce descriptors of shape and surface properties that quantify the global and local features of proteins. Finally, we highlight the current limitations of protein descriptors and propose strategies for the derivation of novel protein descriptors that are more informative. KW - Prediction of molecular features KW - Protein structure complexity KW - Quantitative structure activity relationship KW - Scalar parameters KW - Shape and surface properties Y1 - 2023 U6 - https://doi.org/10.1016/j.csbj.2023.05.022 SN - 2001-0370 (online-ressource) IS - 21 SP - 3234 EP - 3247 PB - Research Network of Computational and Structural Biotechnology CY - Gotenburg ER - TY - JOUR A1 - Hirschfeld, Julian A. A1 - Lustfeld, Hans A1 - Reißel, Martin A1 - Steffen, Bernhard T1 - A novel scheme for precise diagnostics and effective stabilization of currents in a fuel cell stack JF - International Journal of Energy Research N2 - A novel scheme for detecting inhomogeneous internal currents in a fuel cell stack is presented. In this paper the scheme is investigated for the case that the flow field plates consist of graphite. Then plates of high conductivity, e.g. aluminium between the flow field plates together with small slits in these plates have three effects: (a) Whenever a local inhomogeneity of the electric current occurs at a particular cell in the stack, this will induce a surface current close to that cell perpendicular to the averaged current. This current can be detected. (b) The plates of high conductivity completely prevent the inhomogeneities from spreading to neighbouring cells. (c) Even at the particular cell the inhomogeneity is suppressed as far as possible. Thus this scheme leads to much better diagnostic possibilities and at the same time reduces electric instabilities to an extent, where they probably become harmless. This scheme will first be explained for a simple model to clarify the idea. However, very precise three dimensional computations using realistic parameters are presented, corroborating the results of the simple model. Y1 - 2010 U6 - https://doi.org/10.1002/er.1662 SN - 0363-907X VL - 34 IS - 3 SP - 293 EP - 301 PB - Wiley CY - London ER - TY - JOUR A1 - Scholz, A. A1 - Ley, Wilfried A1 - Dachwald, Bernd A1 - Miau, J. J. A1 - Juang, J. C. T1 - Flight results of the COMPASS-1 picosatellite mission JF - Acta Astronautica N2 - The mission of the COMPASS-1 picosatellite is to take pictures of the earth, to validate a space-borne GPS receiver developed by the German Aerospace Center, and to verify the proper operation of the magnetic attitude control system in orbit. The spacecraft was launched on April 28, 2008 from the Indian space port Sriharikota, as part of the PSLV-C9 world record launch that simultaneously brought ten satellites into orbit. The mission operations were carried out from the ground stations in Aachen and Tainan. Arising difficulties in the communication link were overcome with the support of individuals from the amateur radio community. After several months of mission operation, abundant housekeeping and mission data has been commanded, received and analyzed and is presented in this paper. Y1 - 2010 U6 - https://doi.org/10.1016/j.actaastro.2010.06.040 SN - 0094-5765 VL - 76 IS - 9-10 SP - 1289 EP - 1298 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hirschfeld, Julian A. A1 - Lustfeld, Hans A1 - Reißel, Martin A1 - Steffen, Bernhard T1 - Tomographic diagnostics of current distributions in a fuel cell stack JF - International Journal of Energy Research N2 - A novel tomographic scheme for analysing the state of any single membrane electrode assembly (MEA) in a stack is suggested. Plates of very high conductivity placed between every fuel cell and slitted in an appropriate manner cause surface currents at well-defined locations of the stack. We show that knowing these surface currents, information about anomalies of the currents in a MEA can be obtained using the methods of tomography. The results are mathematically not unique. However, when assuming plausible defect structures, one can exclude improbable deficiencies by applying a special form of simulated annealing. We present numerical calculations of typical examples demonstrating that the essential defects of the MEA in any single cell of the stack can be detected and their extent can be determined. Y1 - 2010 U6 - https://doi.org/10.1002/er.1634 SN - 0363-907X VL - 34 IS - 3 SP - 284 EP - 292 PB - Wiley CY - London ER - TY - JOUR A1 - Heinrichs, U. A1 - Pietrzyk, Uwe A1 - Ziemons, Karl T1 - Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 JF - IEEE Transactions on Nuclear Science N2 - Within the Crystal Clear Collaboration (CCC), four centers are developing second generation high performance small animal positron emission tomography (PET) scanners for different kinds of animals and medical applications. The first prototypes are photomultiplier tube (PMT)-based systems including depth of interaction (DOI) detection by using a phoswich layer of lutetium oxyorthosilicate (LSO) and lutetium yttrium aluminum perovskite (LuYAP). The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in fields of view (FOVs) caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN, Geneva, Switzerland) was used. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 5 SP - 1428 EP - 1432 ER - TY - JOUR A1 - Müller, Martin A1 - Hirschfeld, Julian A. A1 - Lambertz, Rita A1 - Schulze Lohoff, Andreas A1 - Lustfeld, Hans A1 - Pfeifer, Heinz A1 - Reißel, Martin T1 - Validation of a novel method for detecting and stabilizing malfunctioning areas in fuel cell stacks JF - Journal of power sources N2 - In this paper a setup for detecting malfunctioning areas of MEAs in fuel cell stacks is described. Malfunctioning areas generate electric cross currents inside bipolar plates. To exploit this we suggest bipolar plates consisting not of two but of three layers. The third one is a highly conducting layer and segmented such that the cross currents move along the segments to the surface of the stack where they can be measured by an inductive sensor. With this information a realistic model can be used to detect the malfunctioning area. Furthermore the third layer will prevent any current inhomogeneity of a malfunctioning cell to spread to neighbouring cells in the stack. In this work the results of measurements in a realistic cell setup will be compared with the results obtained in simulation studies with the same configuration. The basis for the comparison is the reliable characterisation of the electrical properties of the cell components and the implication of these results into the simulation model. The experimental studies will also show the limits in the maximum number of segments, which can be used for a reliable detection of cross currents. Y1 - 2014 U6 - https://doi.org/10.1016/j.jpowsour.2014.08.045 SN - 1873-2755 (E-Journal); 0378-7753 (Print) VL - 272 SP - 225 EP - 232 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Mang, Thomas A1 - Hodenius, Michael A. J. A1 - Schmitz-Rode, Thomas A1 - Baumann, Martin A1 - Ivanova, Gergana A1 - Wong, John Erik A1 - Haulena, Friedhelm A1 - Soenen, Stefaan J. H. A1 - de Cuyper, Marcel T1 - Absorption of 10-hydroxycamptothecin into the coat of magnetoliposomes / Hodenius, M. A. J. ; Schmitz-Rode, T. ; Baumann, M. ; Ivoanova, G. ; Wong, J. E. ; Mang, T. ; Haulena, F. ; Soenen, S. J. H. ; De Cuyper, M. JF - Colloids and Surfaces A: Physicochemical and Engineering Aspects. 343 (2009), H. 1-3 Y1 - 2009 SN - 0927-7757 N1 - Colloid and Surface Science for Nanotechnology SP - 20 EP - 23 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Reißel, Martin A1 - Lustfeld, Hans A1 - Hirschfeld, Julian A. A1 - Steffen, Bernhard T1 - Uniqueness of magnetotomography for fuel cells and fuel cell stacks / Lustfeld, H. ; Hirschfeld, J. ; Reißel, M ; Steffen, B. JF - Journal of Physics A: Mathematical and Theoretical. 42 (2009), H. 495205 Y1 - 2009 SN - 0022-3689 SP - 9 S. ER - TY - JOUR A1 - Reißel, Martin A1 - Lustfeld, Hans A1 - Steffen, Bernhard A1 - Schmidt, U. T1 - Reconstruction of Electric Currents in a Fuel Cell by Magnetic Field Measurements / Lustfeld, H. ; Reißel, M. ; Steffen, B. ; Schmidt, U. JF - Journal of fuel cell science and technology Y1 - 2009 SN - 1550-624X VL - Vol. 6 IS - Iss. 2 SP - 021012-1 EP - 021012-8 ER - TY - JOUR A1 - Reißel, Martin A1 - Hirschfeld, Julian A. A1 - Lustfeld, Hans A1 - Steffen, Bernhard T1 - Magnetotomography and Electric Currents in a Fuel Cell / Lustfeld, H. ; Reißel, M. ; Steffen, B. JF - Fuel Cells. 9 (2009), H. 4 Y1 - 2009 SN - 1615-6854 SP - 474 EP - 481 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Lustfeld, Hans A1 - Hirschfeld, Julian A. A1 - Reißel, Martin A1 - Steffen, Bernhard T1 - Enhancement of precision and reduction of measuring points in tomographic reconstructions JF - Physics Letters A Y1 - 2011 SN - 0375-9601 VL - 375 IS - 8 SP - 1167 EP - 1171 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ortner, Marion A1 - Hauser, Christine A1 - Schmaderer, Christoph A1 - Muggenthaler, Claudia A1 - Hapfelmeier, Alexander A1 - Sorg, Christian A1 - Diehl-Schmid, Janine A1 - Kurz, Alexander A1 - Förstl, Hans A1 - Ikenberg, Benno A1 - Kotliar, Konstantin A1 - Holger, Poppert A1 - Grimmer, Timo T1 - Decreased vascular pulsatility in Alzheimer’s disease dementia measured by transcranial color-coded duplex sonography JF - Neuropsychiatric disease and treatment N2 - Purpose: Impaired paravascular drainage of β-Amyloid (Aβ) has been proposed as a contributing cause for sporadic Alzheimer’s disease (AD), as decreased cerebral blood vessel pulsatility and subsequently reduced propulsion in this pathway could lead to the accumulation and deposition of Aβ in the brain. Therefore, we hypothesized that there is an increased impairment in pulsatility across AD spectrum. Patients and Methods: Using transcranial color-coded duplex sonography (TCCS) the resistance and pulsatility index (RI; PI) of the middle cerebral artery (MCA) in healthy controls (HC, n=14) and patients with AD dementia (ADD, n=12) were measured. In a second step, we extended the sample by adding patients with mild cognitive impairment (MCI) stratified by the presence (MCI-AD, n=8) or absence of biomarkers (MCI-nonAD, n=8) indicative for underlying AD pathology, and compared RI and PI across the groups. To control for atherosclerosis as a confounder, we measured the arteriolar-venular-ratio of retinal vessels. Results: Left and right RI (p=0.020; p=0.027) and left PI (p=0.034) differed between HC and ADD controlled for atherosclerosis with AUCs of 0.776, 0.763, and 0.718, respectively. The RI and PI of MCI-AD tended towards ADD, of MCI-nonAD towards HC, respectively. RIs and PIs were associated with disease severity (p=0.010, p=0.023). Conclusion: Our results strengthen the hypothesis that impaired pulsatility could cause impaired amyloid clearance from the brain and thereby might contribute to the development of AD. However, further studies considering other factors possibly influencing amyloid clearance as well as larger sample sizes are needed. Y1 - 2019 U6 - https://doi.org/10.2147/NDT.S225754 SN - 1178-2021 IS - 15 SP - 3487 EP - 3499 PB - Dove Medical Press CY - Albany, Auckland ER - TY - JOUR A1 - Knödler, Matthias A1 - Rühl, Clemens A1 - Emonts, Jessica A1 - Buyel, Johannes Felix T1 - Seasonal weather changes affect the yield and quality of recombinant proteins produced in transgenic tobacco plants in a greenhouse setting JF - Frontiers in Plant Science N2 - Transgenic plants have the potential to produce recombinant proteins on an agricultural scale, with yields of several tons per year. The cost-effectiveness of transgenic plants increases if simple cultivation facilities such as greenhouses can be used for production. In such a setting, we expressed a novel affinity ligand based on the fluorescent protein DsRed, which we used as a carrier for the linear epitope ELDKWA from the HIV-neutralizing antibody 2F5. The DsRed-2F5-epitope (DFE) fusion protein was produced in 12 consecutive batches of transgenic tobacco (Nicotiana tabacum) plants over the course of 2 years and was purified using a combination of blanching and immobilized metal-ion affinity chromatography (IMAC). The average purity after IMAC was 57 ± 26% (n = 24) in terms of total soluble protein, but the average yield of pure DFE (12 mg kg−1) showed substantial variation (± 97 mg kg−1, n = 24) which correlated with seasonal changes. Specifically, we found that temperature peaks (>28°C) and intense illuminance (>45 klx h−1) were associated with lower DFE yields after purification, reflecting the loss of the epitope-containing C-terminus in up to 90% of the product. Whereas the weather factors were of limited use to predict product yields of individual harvests conducted for each batch (spaced by 1 week), the average batch yields were well approximated by simple linear regression models using two independent variables for prediction (illuminance and plant age). Interestingly, accumulation levels determined by fluorescence analysis were not affected by weather conditions but positively correlated with plant age, suggesting that the product was still expressed at high levels, but the extreme conditions affected its stability, albeit still preserving the fluorophore function. The efficient production of intact recombinant proteins in plants may therefore require adequate climate control and shading in greenhouses or even cultivation in fully controlled indoor farms. KW - batch reproducibility KW - environmental correlation KW - fluorescent protein carrier KW - greenhouse cultivation KW - plant molecular farming Y1 - 2019 U6 - https://doi.org/10.3389/fpls.2019.01245 SN - 1664-462X (online-ressource) IS - 10 PB - Frontiers Media CY - Lausanne ER - TY - JOUR A1 - Bandlitz, Stefan A1 - Nakhoul, Makram A1 - Kotliar, Konstantin T1 - Daily variations of corneal white-to-white diameter measured with different methods JF - Clinical and experimental optometry N2 - Purpose: A precise determination of the corneal diameter is essential for the diagnosis of various ocular diseases, cataract and refractive surgery as well as for the selection and fitting of contact lenses. The aim of this study was to investigate the agreement between two automatic and one manual method for corneal diameter determination and to evaluate possible diurnal variations in corneal diameter. Patients and Methods: Horizontal white-to-white corneal diameter of 20 volunteers was measured at three different fixed times of a day with three methods: Scheimpflug method (Pentacam HR, Oculus), placido based topography (Keratograph 5M, Oculus) and manual method using an image analysis software at a slitlamp (BQ900, Haag-Streit). Results: The two-factorial analysis of variance could not show a significant effect of the different instruments (p = 0.117), the different time points (p = 0.506) and the interaction between instrument and time point (p = 0.182). Very good repeatability (intraclass correlation coefficient ICC, quartile coefficient of dispersion QCD) was found for all three devices. However, manual slitlamp measurements showed a higher QCD than the automatic measurements with the Keratograph 5M and the Pentacam HR at all measurement times. Conclusion: The manual and automated methods used in the study to determine corneal diameter showed good agreement and repeatability. No significant diurnal variations of corneal diameter were observed during the period of time studied. Y1 - 2022 U6 - https://doi.org/10.2147/OPTO.S360651 SN - 0816-4622 IS - 14 SP - 173 EP - 181 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Heinrichs, U. A1 - Pietrzyk, Uwe A1 - Ziemons, Karl T1 - Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 JF - 2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - Within the Crystal Clear Collaboration four centres are developing 2nd generation high performance small animal PET scanners for different kinds of animals and medical applications. The first prototypes are PMT-based systems including depth of interaction (DOI) detection by using a phoswich layer of LSO and LuYAP. The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in FOVs caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN) was used. The simulations have shown that all PMT designs with one-to-one coupling of crystals have a very nonlinear axial sensitivity profile. By shifting every other PMT 1/4 of a PMT length in axial direction the sampling of the FOVs became more homogeneous. At an energy threshold of 350keV the regression coefficient increases from 0.818 for the non-shifted to 0.993 for the shifted design. Simulations of a point source centred in the FOV (threshold: 350keV) resulted in sensitivities of 4.2% for a 4×20PMT (LSO/LuYAP a 10mm) and 3.8% for a 4×16PMT (LSO/LuYAP a 8mm) ring design. The 3D-MLEM reconstruction of a point source shows the enormous improvement of resolution using a crystal double layer with DOI (3.1mm at 40mm from CFOV) instead of a 20mm single layer (11.9mm). Y1 - 2003 SN - 1082-3654 SP - 682 EP - 686 ER - TY - JOUR A1 - Lustfeld, Hans A1 - Pithan, C. A1 - Reißel, Martin T1 - Metallic electrolyte composites in the framework of the brick-layer model JF - Journal of the European Ceramic Society N2 - It is well known that the already large dielectric constants of some electrolytes like BaTiO₃ can be enhanced further by adding metallic (e.g. Ni, Cu or Ag) nanoparticles. The enhancement can be quite large, a factor of more than 1000 is possible. The consequences for the properties will be discussed in the present paper applying a brick-layer model (BLM) for calculating dc-resistivities of thin layers and a modified one (PBLM) that includes percolation for calculating dielectric properties of these materials. The PBLM results in an at least qualitative description and understanding of the physical phenomena: This model gives an explanation for the steep increase of the dielectric constant below the percolation threshold and why this increase is connected to a dramatic decrease of the breakdown voltage as well as the ability of storing electrical energy. We conclude that metallic electrolyte composites like BaTiO₃ are not appropriate for energy storage. Y1 - 2012 U6 - https://doi.org/10.1016/j.jeurceramsoc.2011.10.017 SN - 0955-2219 VL - 32 IS - 4 SP - 859 EP - 864 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Dachwald, Bernd A1 - Mikucki, Jill A1 - Tulaczyk, Slawek A1 - Digel, Ilya A1 - Espe, Clemens A1 - Feldmann, Marco A1 - Francke, Gero A1 - Kowalski, Julia A1 - Xu, Changsheng T1 - IceMole : A maneuverable probe for clean in situ analysis and sampling of subsurface ice and subglacial aquatic ecosystems JF - Annals of Glaciology N2 - There is significant interest in sampling subglacial environments for geobiological studies, but they are difficult to access. Existing ice-drilling technologies make it cumbersome to maintain microbiologically clean access for sample acquisition and environmental stewardship of potentially fragile subglacial aquatic ecosystems. The IceMole is a maneuverable subsurface ice probe for clean in situ analysis and sampling of glacial ice and subglacial materials. The design is based on the novel concept of combining melting and mechanical propulsion. It can change melting direction by differential heating of the melting head and optional side-wall heaters. The first two prototypes were successfully tested between 2010 and 2012 on glaciers in Switzerland and Iceland. They demonstrated downward, horizontal and upward melting, as well as curve driving and dirt layer penetration. A more advanced probe is currently under development as part of the Enceladus Explorer (EnEx) project. It offers systems for obstacle avoidance, target detection, and navigation in ice. For the EnEx-IceMole, we will pay particular attention to clean protocols for the sampling of subglacial materials for biogeochemical analysis. We plan to use this probe for clean access into a unique subglacial aquatic environment at Blood Falls, Antarctica, with return of a subglacial brine sample. KW - Antarctic Glaciology KW - Extraterrestrial Glaciology KW - Glaciological instruments and methods KW - Subclacial exploration KW - Subglacial lakes Y1 - 2014 U6 - https://doi.org/10.3189/2014AoG65A004 SN - 1727-5644 VL - 55 IS - 65 SP - 14 EP - 22 PB - Cambridge University Press CY - Cambridge ER - TY - JOUR A1 - Staat, Manfred A1 - Sponagel, Stefan A1 - Nguyen, Nhu Huynh T1 - Experiment and material model for soft tissue materials JF - Constitutive models for rubber VI N2 - Biomechanics studies biological soft tissue materials (growth, remodeling) in vivo. For this objective, the detailed information of material properties must be well defined to construct reliable constitutive models. In the paper, the bulge test is carried out with elastomers in order to develop a test method. Then, application of the test for soft tissue materials is straightforward due to the similarities between elastomers with soft tissue materials as proved in Holzapfel 2005, Ogden 2009. It means, after the preliminary experiments and parameter identification with rubber materials has been setup, experiments on soft tissue materials can be similarly carried out. Elastomers have a complex behavior which strongly depends on the largest previous load cycle. For simplicity we consider only the first loading. Y1 - 2010 SN - 9780429206597 (eBook) U6 - https://doi.org/10.1201/NOE0415563277-90 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Schmidt, Katharina A1 - Forkmann, Katarina A1 - Schultz, Heidrun A1 - Gratz, Marcel A1 - Bitz, Andreas A1 - Wiech, Katja A1 - Bingel, Ulrike T1 - Enhanced Neural Reinstatement for Evoked Facial Pain Compared With Evoked Hand Pain JF - The Journal of Pain Y1 - 2019 U6 - https://doi.org/10.1016/j.jpain.2019.03.003 SN - 1526-5900 IS - In Press, Corrected Proof PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Hanssen, Henner A1 - Eberhardt, Karla A1 - Vilser, Walthard A1 - Schmaderer, Christoph A1 - Halle, Martin A1 - Heemann, Uwe A1 - Baumann, Marcus T1 - Retinal pulse wave velocity in young male normotensive and mildly hypertensive subjects JF - Microcirculation Y1 - 2013 SN - 1549-8719 N1 - Accepted Article (Accepted, unedited articles published online and citable. The final edited and typeset version of record will appear in future.) PB - Wiley CY - Malden ER - TY - JOUR A1 - Kowalski, Julia A1 - Linder, Peter A1 - Zierke, S. A1 - Wulfen, B. van A1 - Clemens, J. A1 - Konstantinidis, K. A1 - Ameres, G. A1 - Hoffmann, R. A1 - Mikucki, J. A1 - Tulaczyk, S. A1 - Funke, O. A1 - Blandfort, D. A1 - Espe, Clemens A1 - Feldmann, Marco A1 - Francke, Gero A1 - Hiecker, S. A1 - Plescher, Engelbert A1 - Schöngarth, Sarah A1 - Dachwald, Bernd A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Eliseev, D. A1 - Heinen, D. A1 - Scholz, F. A1 - Wiebusch, C. A1 - Macht, S. A1 - Bestmann, U. A1 - Reineking, T. A1 - Zetzsche, C. A1 - Schill, K. A1 - Förstner, R. A1 - Niedermeier, H. A1 - Szumski, A. A1 - Eissfeller, B. A1 - Naumann, U. A1 - Helbing, K. T1 - Navigation technology for exploration of glacier ice with maneuverable melting probes JF - Cold Regions Science and Technology N2 - The Saturnian moon Enceladus with its extensive water bodies underneath a thick ice sheet cover is a potential candidate for extraterrestrial life. Direct exploration of such extraterrestrial aquatic ecosystems requires advanced access and sampling technologies with a high level of autonomy. A new technological approach has been developed as part of the collaborative research project Enceladus Explorer (EnEx). The concept is based upon a minimally invasive melting probe called the IceMole. The force-regulated, heater-controlled IceMole is able to travel along a curved trajectory as well as upwards. Hence, it allows maneuvers which may be necessary for obstacle avoidance or target selection. Maneuverability, however, necessitates a sophisticated on-board navigation system capable of autonomous operations. The development of such a navigational system has been the focal part of the EnEx project. The original IceMole has been further developed to include relative positioning based on in-ice attitude determination, acoustic positioning, ultrasonic obstacle and target detection integrated through a high-level sensor fusion. This paper describes the EnEx technology and discusses implications for an actual extraterrestrial mission concept. Y1 - 2016 U6 - https://doi.org/10.1016/j.coldregions.2015.11.006 SN - 0165-232X IS - 123 SP - 53 EP - 70 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schmidt, Katharina A1 - Forkmann, Katarina A1 - Sinke, C. A1 - Gratz, Marcel A1 - Bitz, Andreas A1 - Bingel, Ulrike T1 - The differential effect of trigeminal vs. peripheral pain stimulation on visual processing and memory encoding is influenced by pain-related fear JF - NeuroImage N2 - Compared to peripheral pain, trigeminal pain elicits higher levels of fear, which is assumed to enhance the interruptive effects of pain on concomitant cognitive processes. In this fMRI study we examined the behavioral and neural effects of trigeminal (forehead) and peripheral (hand) pain on visual processing and memory encoding. Cerebral activity was measured in 23 healthy subjects performing a visual categorization task that was immediately followed by a surprise recognition task. During the categorization task subjects received concomitant noxious electrical stimulation on the forehead or hand. Our data show that fear ratings were significantly higher for trigeminal pain. Categorization and recognition performance did not differ between pictures that were presented with trigeminal and peripheral pain. However, object categorization in the presence of trigeminal pain was associated with stronger activity in task-relevant visual areas (lateral occipital complex, LOC), memory encoding areas (hippocampus and parahippocampus) and areas implicated in emotional processing (amygdala) compared to peripheral pain. Further, individual differences in neural activation between the trigeminal and the peripheral condition were positively related to differences in fear ratings between both conditions. Functional connectivity between amygdala and LOC was increased during trigeminal compared to peripheral painful stimulation. Fear-driven compensatory resource activation seems to be enhanced for trigeminal stimuli, presumably due to their exceptional biological relevance. Y1 - 2016 U6 - https://doi.org/10.1016/j.neuroimage.2016.03.026 SN - 1053-8119 VL - 134 SP - 386 EP - 395 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Balakrishnan, Karthikeyan A1 - Andrei-Selmer, Luminita-Cornelia A1 - Selmer, Thorsten A1 - Bacher, Michael A1 - Dodel, Richard T1 - Comparison of intravenous immunoglobulins for naturally occurring autoantibodies against amyloid-β JF - Journal of Alzheimer's Disease N2 - Intravenous immunoglobulins (IVIG) are currently used for therapeutic purposes in autoimmune disorders. Recently, we demonstrated the presence of naturally occurring antibodies against amyloid- β (nAbs-Aβ) within the pool of IVIG. In this study, we compared different brands of IVIG for nAbs-Aβ and have found differences in the specificity of the nAbs-Aβ towards Aβ1–40 and Aβ1–42 . We analyzed the influence of a pH-shift over the course of antibody storage using ELISA and investigated antibody dimerization at acidic and neutral pH as well as differences in the IgG subclass distributions among the IVIG using both HPLC and a nephelometric assay. Furthermore, we investigated the epitope region of purified nAbs-Aβ. The differences found in Aβ specificity are not directly proportionate to the binding nature of these antibodies when administered in vivo. This information, however, may serve as a guide when choosing the commercial source of IVIG for therapeutic applications in Alzheimer's disease Y1 - 2010 U6 - https://doi.org/10.3233/JAD-2010-1353 SN - 1387-2877 VL - 20 IS - 1 SP - 135 EP - 143 PB - IOS Press CY - Amsterdam ER - TY - JOUR A1 - Alexopoulos, Spiros A1 - Hoffschmidt, Bernhard T1 - Solar tower power plant in Germany and future perspectives of the development of the technology in Greece and Cyprus JF - Renewable Energy N2 - Since the 80s power production with solar thermal power plants has been a way to substitute fossil fuels. By concentrating direct solar radiation from heliostats very high temperatures of a thermal fluid can be reached. The resulting heat is converted to mechanical energy in a steam cycle which generates electricity. High efficiencies and fast start-up are reached by using air as a heat medium, as well as using porous ceramic materials as solar receiver of the concentrated sunlight. In Germany the construction of a 1.5 MWe solar tower power plant began in 2008. It is operational since December 2008 and started production of electricity in the spring of 2009. In Greece and Cyprus, countries with high solar potential, the development of this competitive solar thermal technology is imperative, since it has already been implemented in other Mediterranean countries. Y1 - 2010 U6 - https://doi.org/10.1016/j.renene.2009.11.003 SN - 0960-1481 VL - 35 IS - 7 SP - 1352 EP - 1356 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Orzada, Stephan A1 - Solbach, Klaus A1 - Gratz, Marcel A1 - Brunheim, Sascha A1 - Fiedler, Thomas M. A1 - Johst, Sören A1 - Bitz, Andreas A1 - Shooshtary, Samaneh A1 - Abuelhaija, Ashraf A1 - Voelker, Maximilian N. A1 - Rietsch, Stefan H. G. A1 - Kraff, Oliver A1 - Maderwald, Stefan A1 - Flöser, Martina A1 - Oehmingen, Mark A1 - Quick, Harald H. A1 - Ladd, Mark E. T1 - A 32-channel parallel transmit system add-on for 7T MRI JF - Plos one Y1 - 2019 U6 - https://doi.org/10.1371/journal.pone.0222452 ER - TY - JOUR A1 - Rietsch, Stefan H. G. A1 - Brunheim, Sascha A1 - Orzada, Stephan A1 - Voelker, Maximilian N. A1 - Maderwald, Stefan A1 - Bitz, Andreas A1 - Gratz, Marcel A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - Development and evaluation of a 16-channel receive-only RF coil to improve 7T ultra-high field body MRI with focus on the spine JF - Magnetic Resonance in Medicine Y1 - 2019 U6 - https://doi.org/10.1002/mrm.27731 SN - 1522-2594 IS - Early view PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Mikucki, Jill Ann A1 - Schuler, C. G. A1 - Digel, Ilya A1 - Kowalski, Julia A1 - Tuttle, M. J. A1 - Chua, Michelle A1 - Davis, R. A1 - Purcell, Alicia A1 - Ghosh, D. A1 - Francke, G. A1 - Feldmann, Marco A1 - Espe, C. A1 - Heinen, Dirk A1 - Dachwald, Bernd A1 - Clemens, Joachim A1 - Lyons, W. B. A1 - Tulaczyk, S. T1 - Field-Based planetary protection operations for melt probes: validation of clean access into the blood falls, antarctica, englacial ecosystem JF - Astrobiology N2 - Subglacial environments on Earth offer important analogs to Ocean World targets in our solar system. These unique microbial ecosystems remain understudied due to the challenges of access through thick glacial ice (tens to hundreds of meters). Additionally, sub-ice collections must be conducted in a clean manner to ensure sample integrity for downstream microbiological and geochemical analyses. We describe the field-based cleaning of a melt probe that was used to collect brine samples from within a glacier conduit at Blood Falls, Antarctica, for geomicrobiological studies. We used a thermoelectric melting probe called the IceMole that was designed to be minimally invasive in that the logistical requirements in support of drilling operations were small and the probe could be cleaned, even in a remote field setting, so as to minimize potential contamination. In our study, the exterior bioburden on the IceMole was reduced to levels measured in most clean rooms, and below that of the ice surrounding our sampling target. Potential microbial contaminants were identified during the cleaning process; however, very few were detected in the final englacial sample collected with the IceMole and were present in extremely low abundances (∼0.063% of 16S rRNA gene amplicon sequences). This cleaning protocol can help minimize contamination when working in remote field locations, support microbiological sampling of terrestrial subglacial environments using melting probes, and help inform planetary protection challenges for Ocean World analog mission concepts. Y1 - 2023 U6 - https://doi.org/10.1089/ast.2021.0102 SN - 1557-8070 (online) SN - 153-1074 (print) VL - 23 IS - 11 SP - 1165 EP - 1178 PB - Liebert CY - New York, NY ER - TY - JOUR A1 - German, Laura A1 - Mikucki, Jill A. A1 - Welch, Susan A. A1 - Welch, Kathleen A. A1 - Lutton, Anthony A1 - Dachwald, Bernd A1 - Kowalski, Julia A1 - Heinen, Dirk A1 - Feldmann, Marco A1 - Francke, Gero A1 - Espe, Clemens A1 - Lyons, W. Berry T1 - Validation of sampling antarctic subglacial hypersaline waters with an electrothermal ice melting probe (IceMole) for environmental analytical geochemistry JF - International Journal of Environmental Analytical Chemistry N2 - Geochemical characterisation of hypersaline waters is difficult as high concentrations of salts hinder the analysis of constituents at low concentrations, such as trace metals, and the collection of samples for trace metal analysis in natural waters can be easily contaminated. This is particularly the case if samples are collected by non-conventional techniques such as those required for aquatic subglacial environments. In this paper we present the first analysis of a subglacial brine from Taylor Valley, (~ 78°S), Antarctica for the trace metals: Ba, Co, Mo, Rb, Sr, V, and U. Samples were collected englacially using an electrothermal melting probe called the IceMole. This probe uses differential heating of a copper head as well as the probe’s sidewalls and an ice screw at the melting head to move through glacier ice. Detailed blanks, meltwater, and subglacial brine samples were collected to evaluate the impact of the IceMole and the borehole pump, the melting and collection process, filtration, and storage on the geochemistry of the samples collected by this device. Comparisons between melt water profiles through the glacier ice and blank analysis, with published studies on ice geochemistry, suggest the potential for minor contributions of some species Rb, As, Co, Mn, Ni, NH4+, and NO2−+NO3− from the IceMole. The ability to conduct detailed chemical analyses of subglacial fluids collected with melting probes is critical for the future exploration of the hundreds of deep subglacial lakes in Antarctica. Y1 - 2021 U6 - https://doi.org/10.1080/03067319.2019.1704750 SN - 0306-7319 VL - 101 IS - 15 SP - 2654 EP - 2667 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Johst, Sören A1 - Gratz, Marcel A1 - Völker, Maximilian N. A1 - Kraff, Oliver A1 - Abuelhaija, Ashraf A1 - Fiedler, Thomas M. A1 - Solbach, Klaus A1 - Quick, Harald H. A1 - Ladd, Mark E. T1 - Analysis of an integrated 8-Channel Tx/Rx body array for use as a body coil in 7-Tesla MRI JF - Frontiers in Physics Y1 - 2017 U6 - https://doi.org/10.3389/fphy.2017.00017 SN - 2296-424X N1 - Article number 17 VL - 5 IS - Jun ER - TY - JOUR A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Wenmackers, Sylvia A1 - Janssens, Stoffel D. A1 - Haenen, Ken A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Capacitive field-effect (bio-)chemical sensors based on nanocrystalline diamond films JF - MRS Online Proceedings Library N2 - Capacitive field-effect electrolyte-diamond-insulator-semiconductor (EDIS) structures with O-terminated nanocrystalline diamond (NCD) as sensitive gate material have been realized and investigated for the detection of pH, penicillin concentration, and layer-by-layer adsorption of polyelectrolytes. The surface oxidizing procedure of NCD thin films as well as the seeding and NCD growth process on a Si-SiO2 substrate have been improved to provide high pH-sensitive, non-porous thin films without damage of the underlying SiO2 layer and with a high coverage of O-terminated sites. The NCD surface topography, roughness, and coverage of the surface groups have been characterized by SEM, AFM and XPS methods. The EDIS sensors with O-terminated NCD film treated in oxidizing boiling mixture for 45 min show a pH sensitivity of about 50 mV/pH. The pH-sensitive properties of the NCD have been used to develop an EDIS-based penicillin biosensor with high sensitivity (65-70 mV/decade in the concentration range of 0.25-2.5 mM penicillin G) and low detection limit (5 μM). The results of label-free electrical detection of layer-by-layer adsorption of charged polyelectrolytes are presented, too. Y1 - 2010 SN - 1946-4274 VL - 1203 PB - MRS CY - Warrendale ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Vu, Khoi Duc A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - A primal-dual algorithm for shakedown analysis of elastic-plastic bounded linearly kinematic hardening bodies Y1 - 2010 N1 - 4th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems in Engineering), ECCOMAS ECCM 2010, Paris, France, May 17 – 21, 2010 ER - TY - JOUR A1 - Nguyen, N.-H. A1 - Raatschen, Hans-Jürgen A1 - Staat, Manfred T1 - A hyperelastic model of biological tissue materials in tubular organs Y1 - 2010 N1 - 4th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems in Engineering), ECCOMAS ECCM 2010, Paris, France, May 17 – 21, 2010 ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - Shakedown analysis of two dimensional structures by an edge-based smoothed finite element method Y1 - 2010 N1 - 4th European Conference on Computational Mechanics (Solids, Structures and Coupled Problems in Engineering), ECCOMAS ECCM 2010, Paris, France, May 17 – 21, 2010 ER - TY - JOUR A1 - Tix, Julian A1 - Moll, Fabian A1 - Krafft, Simone A1 - Betsch, Matthias A1 - Tippkötter, Nils T1 - Hydrogen production from enzymatic pretreated organic waste with thermotoga neapolitana JF - Energies N2 - Biomass from various types of organic waste was tested for possible use in hydrogen production. The composition consisted of lignified samples, green waste, and kitchen scraps such as fruit and vegetable peels and leftover food. For this purpose, the enzymatic pretreatment of organic waste with a combination of five different hydrolytic enzymes (cellulase, amylase, glucoamylase, pectinase and xylase) was investigated to determine its ability to produce hydrogen (H2) with the hydrolyzate produced here. In course, the anaerobic rod-shaped bacterium T. neapolitana was used for H2 production. First, the enzymes were investigated using different substrates in preliminary experiments. Subsequently, hydrolyses were carried out using different types of organic waste. In the hydrolysis carried out here for 48 h, an increase in glucose concentration of 481% was measured for waste loads containing starch, corresponding to a glucose concentration at the end of hydrolysis of 7.5 g·L−1. In the subsequent set fermentation in serum bottles, a H2 yield of 1.26 mmol H2 was obtained in the overhead space when Terrific Broth Medium with glucose and yeast extract (TBGY medium) was used. When hydrolyzed organic waste was used, even a H2 yield of 1.37 mmol could be achieved in the overhead space. In addition, a dedicated reactor system for the anaerobic fermentation of T. neapolitana to produce H2 was developed. The bioreactor developed here can ferment anaerobically with a very low loss of produced gas. Here, after 24 h, a hydrogen concentration of 83% could be measured in the overhead space. KW - biological hydrogen KW - organic waste KW - dark fermentation KW - hydrolysis KW - pretreatment Y1 - 2024 U6 - https://doi.org/10.3390/en17122938 SN - 1996-1073 N1 - Corresponding author: Nils Tippkötter VL - 17 IS - 12 PB - MDPI CY - Basel ER - TY - JOUR A1 - Varriale, Ludovica A1 - Hengsbach, Jan-Niklas A1 - Guo, Tianyi A1 - Kuka, Katrin A1 - Tippkötter, Nils A1 - Ulber, Roland T1 - Sustainable production of lactic acid using a perennial ryegrass as feedstock—a comparative study of fermentation at the bench- and reactor-scale, and ensiling JF - Sustainability N2 - Perennial ryegrass (Lolium perenne) is an underutilized lignocellulosic biomass that has several benefits such as high availability, renewability, and biomass yield. The grass press-juice obtained from the mechanical pretreatment can be used for the bio-based production of chemicals. Lactic acid is a platform chemical that has attracted consideration due to its broad area of applications. For this reason, the more sustainable production of lactic acid is expected to increase. In this work, lactic acid was produced using complex medium at the bench- and reactor scale, and the results were compared to those obtained using an optimized press-juice medium. Bench-scale fermentations were carried out in a pH-control system and lactic acid production reached approximately 21.84 ± 0.95 g/L in complex medium, and 26.61 ± 1.2 g/L in press-juice medium. In the bioreactor, the production yield was 0.91 ± 0.07 g/g, corresponding to a 1.4-fold increase with respect to the complex medium with fructose. As a comparison to the traditional ensiling process, the ensiling of whole grass fractions of different varieties harvested in summer and autumn was performed. Ensiling showed variations in lactic acid yields, with a yield up to 15.2% dry mass for the late-harvested samples, surpassing typical silage yields of 6–10% dry mass. KW - lactobacillus KW - lactic acid KW - ensiling KW - fermentation KW - perennial ryegrass KW - renewable resources KW - bio-based economy Y1 - 2024 U6 - https://doi.org/10.3390/su16188054 SN - 2071-1050 N1 - This article belongs to the Section "Environmental Sustainability and Applications" VL - 16 IS - 18 PB - MDPI CY - Basel ER - TY - JOUR A1 - Wendlandt, Tim A1 - Koch, Claudia A1 - Britz, Beate A1 - Liedek, Anke A1 - Schmidt, Nora A1 - Werner, Stefan A1 - Gleba, Yuri A1 - Vahidpour, Farnoosh A1 - Welden, Melanie A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Facile Purification and Use of Tobamoviral Nanocarriers for Antibody-Mediated Display of a Two-Enzyme System JF - Viruses N2 - Immunosorbent turnip vein clearing virus (TVCV) particles displaying the IgG-binding domains D and E of Staphylococcus aureus protein A (PA) on every coat protein (CP) subunit (TVCVPA) were purified from plants via optimized and new protocols. The latter used polyethylene glycol (PEG) raw precipitates, from which virions were selectively re-solubilized in reverse PEG concentration gradients. This procedure improved the integrity of both TVCVPA and the wild-type subgroup 3 tobamovirus. TVCVPA could be loaded with more than 500 IgGs per virion, which mediated the immunocapture of fluorescent dyes, GFP, and active enzymes. Bi-enzyme ensembles of cooperating glucose oxidase and horseradish peroxidase were tethered together on the TVCVPA carriers via a single antibody type, with one enzyme conjugated chemically to its Fc region, and the other one bound as a target, yielding synthetic multi-enzyme complexes. In microtiter plates, the TVCVPA-displayed sugar-sensing system possessed a considerably increased reusability upon repeated testing, compared to the IgG-bound enzyme pair in the absence of the virus. A high coverage of the viral adapters was also achieved on Ta2O5 sensor chip surfaces coated with a polyelectrolyte interlayer, as a prerequisite for durable TVCVPA-assisted electrochemical biosensing via modularly IgG-assembled sensor enzymes. KW - biosensor KW - horseradish peroxidase (HRP) KW - glucose oxidase (GOx) KW - enzyme cascade KW - turnip vein clearing virus (TVCV) KW - tobacco mosaic virus (TMV) Y1 - 2023 U6 - https://doi.org/doi.org/10.3390/v15091951 SN - 1999-4915 N1 - This article belongs to the Special Issue "Tobamoviruses 2023" VL - 9 IS - 15 PB - MDPI CY - Basel ER - TY - JOUR A1 - Bäcker, Matthias A1 - Koch, Claudia A1 - Eiben, Sabine A1 - Geiger, Fania A1 - Eber, Fabian A1 - Gliemann, Hartmut A1 - Poghossian, Arshak A1 - Wege, Christina A1 - Schöning, Michael Josef T1 - Tobacco mosaic virus as enzyme nanocarrier for electrochemical biosensors JF - Sensors and Actuators B: Chemical N2 - The conjunction of (bio-)chemical recognition elements with nanoscale biological building blocks such as virus particles is considered as a very promising strategy for the creation of biohybrids opening novel opportunities for label-free biosensing. This work presents a new approach for the development of biosensors using tobacco mosaic virus (TMV) nanotubes or coat proteins (CPs) as enzyme nanocarriers. Sensor chips combining an array of Pt electrodes loaded with glucose oxidase (GOD)-modified TMV nanotubes or CP aggregates were used for amperometric detection of glucose as a model system for the first time. The presence of TMV nanotubes or CPs on the sensor surface allows binding of a high amount of precisely positioned enzymes without substantial loss of their activity, and may also ensure accessibility of their active centers for analyte molecules. Specific and efficient immobilization of streptavidin-conjugated GOD ([SA]-GOD) complexes on biotinylated TMV nanotubes or CPs was achieved via bioaffinity binding. These layouts were tested in parallel with glucose sensors with adsorptively immobilized [SA]-GOD, as well as [SA]-GOD crosslinked with glutardialdehyde, and came out to exhibit superior sensor performance. The achieved results underline a great potential of an integration of virus/biomolecule hybrids with electronic transducers for future applications in biosensorics and biochips. Y1 - 2017 U6 - https://doi.org/10.1016/j.snb.2016.07.096 SN - 0925-4005 VL - 238 SP - 716 EP - 722 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Koch, Claudia A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Wege, Christian T1 - Penicillin Detection by Tobacco Mosaic Virus-Assisted Colorimetric Biosensors JF - Nanotheranostics N2 - The presentation of enzymes on viral scaffolds has beneficial effects such as an increased enzyme loading and a prolonged reusability in comparison to conventional immobilization platforms. Here, we used modified tobacco mosaic virus (TMV) nanorods as enzyme carriers in penicillin G detection for the first time. Penicillinase enzymes were conjugated with streptavidin and coupled to TMV rods by use of a bifunctional biotin-linker. Penicillinase-decorated TMV particles were characterized extensively in halochromic dye-based biosensing. Acidometric analyte detection was performed with bromcresol purple as pH indicator and spectrophotometry. The TMV-assisted sensors exhibited increased enzyme loading and strongly improved reusability, and higher analysis rates compared to layouts without viral adapters. They extended the half-life of the sensors from 4 - 6 days to 5 weeks and thus allowed an at least 8-fold longer use of the sensors. Using a commercial budget-priced penicillinase preparation, a detection limit of 100 µM penicillin was obtained. Initial experiments also indicate that the system may be transferred to label-free detection layouts. Y1 - 2018 U6 - https://doi.org/10.7150/ntno.22114 SN - 2206-7418 VL - 2 IS - 2 SP - 184 EP - 196 PB - Ivyspring CY - Sydney ER - TY - JOUR A1 - Spietz, Peter A1 - Spröwitz, Tom A1 - Seefeldt, Patric A1 - Grundmann, Jan Thimo A1 - Jahnke, Rico A1 - Mikschl, Tobias A1 - Mikulz, Eugen A1 - Montenegro, Sergio A1 - Reershemius, Siebo A1 - Renger, Thomas A1 - Ruffer, Michael A1 - Sasaki, Kaname A1 - Sznajder, Maciej A1 - Tóth, Norbert A1 - Ceriotti, Matteo A1 - Dachwald, Bernd A1 - Macdonald, Malcolm A1 - McInnes, Colin A1 - Seboldt, Wolfgang A1 - Quantius, Dominik A1 - Bauer, Waldemar A1 - Wiedemann, Carsten A1 - Grimm, Christian D. A1 - Hercik, David A1 - Ho, Tra-Mi A1 - Lange, Caroline A1 - Schmitz, Nicole T1 - Paths not taken – The Gossamer roadmap’s other options JF - Advances in Space Research KW - Solar sail KW - Small spacecraft KW - DLR-ESTEC GOSSAMER roadmap for solar sailing KW - GOSSAMER-1 Y1 - 2021 U6 - https://doi.org/10.1016/j.asr.2021.01.044 SN - 0273-1177 VL - 67 IS - 9 SP - 2912 EP - 2956 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Beging, Stefan A1 - Mlynek, Daniela A1 - Hataihimakul, Sudkanung A1 - Poghossian, Arshak A1 - Baldsiefen, Gerhard A1 - Busch, Heinz A1 - Laube, Norbert A1 - Kleinen, Lisa A1 - Schöning, Michael Josef T1 - Field-effect calcium sensor for the determination of the risk of urinary stone formation JF - Sensors and Actuators B: Chemical N2 - Urinary stone formation has been evolved to a widespread disease during the last years. The reason for the formation of urinary stones are little crystals, mostly composed of calcium oxalate, which are formed in human kidneys. The early diagnosis of the risk for urinary stone formation of patients can be determined by the “Bonn-Risk-Index” method based on the potentiometric detection of the Ca2+-ion concentration and an optical determination of the triggered crystallisation of calcium oxalate in unprocessed urine. In this work, miniaturised capacitive field-effect EMIS (electrolyte-membrane-insulator-semiconductor) sensors have been developed for the determination of the Ca2+-ion concentration in human native urine. The Ca2+-sensitive EMIS sensors have been systematically characterised by impedance spectroscopy, capacitance–voltage and constant–capacitance method in terms of sensitivity, signal stability and response time in both CaCl2 solutions and in native urine. The obtained results demonstrate the suitability of EMIS sensors for the measurement of the Ca2+-ion concentration in native urine of patients. Y1 - 2010 U6 - https://doi.org/10.1016/j.snb.2008.12.012 SN - 0925-4005 N1 - 22nd International Conference on Eurosensors: Dresden, Germany, 7-10 September 2008 VL - 144 IS - 2 SP - 374 EP - 379 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Reisert, Steffen A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schäfer, Daniel A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Schöning, Michael Josef T1 - Development of a handheld sensor system for the online measurement of hydrogen peroxide in aseptic filling systems JF - Physica Status Solidi (A) N2 - A handheld sensor system for the online measurement of hydrogen peroxide (H2O2) in aseptic sterilisation processes has been developed. It is based on a calorimetric-type gas sensor that consists of a differential set-up of two temperature sensors, of which one is catalytically activated and the second one is passivated and used as reference. The sensor principle relies in detecting a rise in temperature on the active sensor due to the exothermic reaction of H2O2 on the catalytic surface. To characterise the sensor system towards H2O2 sensitivity and other influencing factors, measurements have been carried out both at an experimental set-up and a manufacturer's sterilisation machine. Physical sensor characterisation was done by means of the optical microscopy. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983304 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 913 EP - 918 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Sugawara, Yuri A1 - Kanoh, Shin´ichiro A1 - Yoshinobu, Tatsuo A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Image correction method for the chemical imaging sensor JF - Sensors and Actuators B: Chemical N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of chemical species. For the practical application of this sensor, artifacts in the chemical images due to defects of the semiconductor substrate and contamination of the sensing surface etc. have been a major problem. An image correction method was developed to eliminate the influence of nonuniformity of individual sensor plate. Y1 - 2010 U6 - https://doi.org/10.1016/j.snb.2008.10.069 SN - 0925-4005 N1 - 22nd International Conference on Eurosensors: Dresden, Germany, 7-10 September 2008 VL - 144 IS - 2 SP - 344 EP - 348 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Unden, Gottfried A1 - Becker, S. A1 - Bongaerts, Johannes A1 - Holighaus, G. A1 - Schirawski, Jan A1 - Six, Simon T1 - O2-sensing and O2-dependent gene regulation in facultatively anaerobic bacteria JF - Archives of microbiology Y1 - 1995 SN - 1432-072X (E-Journal); 0003-9276 (Print); 0302-8933 (Print) VL - Vol. 164 IS - Iss. 2 SP - 81 EP - 90 ER - TY - JOUR A1 - Hoffschmidt, Bernhard A1 - Becker, Manfred A1 - Fend, Thomas T1 - Theoretical and numerical investigation of flow stability in porous materials applied as volumetric solar receivers / M. Becker ; T. Fend ; B. Hoffschmidt ... JF - Solar energy. 80 (2006), H. 10 Y1 - 2006 SN - 0038-092X N1 - Solar Power and Chemical Energy Systems (SolarPACES’04) SP - 1241 EP - 1248 ER - TY - JOUR A1 - Unden, Gottfried A1 - Becker, S. A1 - Bongaerts, Johannes A1 - Schirawski, Jan A1 - Six, Simon T1 - Oxygen regulated gene expression in facultatively anaerobic bacteria JF - Antonie van Leeuwenhoek Y1 - 1994 SN - 0003-6072 (Print) ; 1572-9699 (online) VL - Vol. 66 IS - Iss. 1-3 SP - 3 EP - 22 ER - TY - JOUR A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Siqueira, José R. Jr. A1 - Oliveira, Osvaldo N. Jr. A1 - Moritz, Werner A1 - Schöning, Michael Josef T1 - Capacitive electrolyte-insulator-semiconductor structures functionalised with a polyelectrolyte/enzyme multilayer: New strategy for enhanced field-effect biosensing JF - Physica Status Solidi (A) N2 - A novel strategy for enhanced field-effect biosensing using capacitive electrolyte–insulator–semiconductor (EIS) structures functionalised with pH-responsive weak polyelectrolyte/enzyme or dendrimer/enzyme multilayers is presented. The feasibility of the proposed approach is exemplarily demonstrated by realising a penicillin biosensor based on a capacitive p-Si–SiO2 EIS structure functionalised with a poly(allylamine hydrochloride) (PAH)/penicillinase and a poly(amidoamine) dendrimer/penicillinase multilayer. The developed sensors response to changes in both the local pH value near the gate surface and the charge of macromolecules induced via enzymatic reaction, resulting in a higher sensitivity. For comparison, an EIS penicillin biosensor with adsorptively immobilised penicillinase has been also studied. The highest penicillin sensitivity of 100 mV/dec has been observed for the EIS sensor functionalised with the PAH/penicillinase multilayer. The lower and upper detection limit was around 20 µM and 10 mM, respectively. In addition, an incorporation of enzymes in a multilayer prepared by layer-by-layer technique provides a larger amount of immobilised enzymes per sensor area, reduces enzyme leaching effects and thus, enhances the biosensor lifetime (the loss of penicillin sensitivity after 2 months was 10–12%). Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983317 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 884 EP - 890 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Tsarouchas, D. A1 - Beckers, Leah A1 - Schubert, J. A1 - Zander, W. A1 - Kordoš, P. A1 - Lüth, Hans T1 - A highly long-term stable silicon-based pH sensor using pulsed laser deposition technique JF - Sensors and Actuators B. 35 (1996), H. 1-3 Y1 - 1996 SN - 0925-4005 SP - 228 EP - 233 ER - TY - JOUR A1 - Schmitz, Günter A1 - Roetert, J. A1 - Pischinger, Martin T1 - A Fast Intelligent VMEbus System for Combustion Analysis in Engines JF - 19th [nineteenth] International Symposium on Automotive Technology & [and] Automation : with particular reference to cell control and quality management systems for the manufacturing industries; Monte Carlo, 24. - 28. October 1988. Y1 - 1988 SN - 0947719229 SP - 381 EP - 391 PB - Automotive Automation Ltd CY - Croydon ER - TY - JOUR A1 - Poghossian, Arshak A1 - Jablonski, Melanie A1 - Koch, Claudia A1 - Bronder, Thomas A1 - Rolka, David A1 - Wege, Christina A1 - Schöning, Michael Josef T1 - Field-effect biosensor using virus particles as scaffolds for enzyme immobilization JF - Biosensors and Bioelectronics N2 - A field-effect biosensor employing tobacco mosaic virus (TMV) particles as scaffolds for enzyme immobilization is presented. Nanotubular TMV scaffolds allow a dense immobilization of precisely positioned enzymes with retained activity. To demonstrate feasibility of this new strategy, a penicillin sensor has been developed by coupling a penicillinase with virus particles as a model system. The developed field-effect penicillin biosensor consists of an Al-p-Si-SiO₂-Ta₂O₅-TMV structure and has been electrochemically characterized in buffer solutions containing different concentrations of penicillin G. In addition, the morphology of the biosensor surface with virus particles was characterized by scanning electron microscopy and atomic force microscopy methods. The sensors possessed a high penicillin sensitivity of ~ 92 mV/dec in a nearly-linear range from 0.1 mM to 10 mM, and a low detection limit of about 50 µM. The long-term stability of the penicillin biosensor was periodically tested over a time period of about one year without any significant loss of sensitivity. The biosensor has also been successfully applied for penicillin detection in bovine milk samples. Y1 - 2018 U6 - https://doi.org/10.1016/j.bios.2018.03.036 SN - 0956-5663 VL - 110 SP - 168 EP - 174 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kirchner, Patrick A1 - Ng, Yue Ann A1 - Spelthahn, Heiko A1 - Schneider, Andreas A1 - Henkel, Hartmut A1 - Friedrich, Peter A1 - Kolstad, Jens A1 - Berger, Jörg A1 - Keusgen, Michael T1 - Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection JF - Physica Status Solidi (A) N2 - In aseptic filling systems, hydrogen peroxide vapour is commonly used for the reduction of microbial contaminations in carton packages. In this process, the germicidal efficiency of the vapour depends especially on the H₂O₂ concentration. To monitor the H₂O₂ concentration, a calorimetric H₂O₂ gas sensor based on a catalytically activated thin-film thermopile is investigated. Two different sensor layouts, namely a circular and a linear form, as well as two various material pairs such as tungsten/nickel and gold/nickel, have been examined for the realization of a thin-film thermopile. Additionally, manganese oxide and palladium particles have been compared as responsive catalysts towards H₂O₂. The thin-film sensors have been investigated at various H₂O₂ concentrations, gas temperatures and flow rates. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983309 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 787 EP - 792 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Chaudhuri, S. A1 - Zander, W. A1 - Schubert, J. A1 - Begoyan, Vardges K. A1 - Buniatyan, V. V. A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Capacitively coupled electrolyte-conductivity sensor based on high-k material of barium strontium titanate JF - Sensors and actuators. B: Chemical Y1 - 2014 U6 - https://doi.org/10.1016/j.snb.2014.02.103 SN - 1873-3077 (E-Journal); 0925-4005 (Print) IS - 198 SP - 102 EP - 109 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Grundmann, Jan Thimo A1 - Dachwald, Bernd A1 - Grimm, Christian D. A1 - Kahle, Ralph A1 - Koch, Aaron Dexter A1 - Krause, Christian A1 - Lange, Caroline A1 - Quantius, Dominik A1 - Ulamec, Stephan T1 - Spacecraft for Hypervelocity Impact Research – An Overview of Capabilities, Constraints and the Challenges of Getting There JF - Procedia Engineering Y1 - 2015 U6 - https://doi.org/10.1016/j.proeng.2015.04.021 SN - 1877-7058 N1 - Proceedings of the 2015 Hypervelocity Impact Symposium (HVIS 2015) VL - Vol. 103 SP - 151 EP - 158 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Buniatyan, Vahe V. A1 - Abouzar, Maryam H. A1 - Martirosyan, Norayr W. A1 - Schubert, Jürgen A1 - Gevorgian, Spartak A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - pH-sensitive properties of barium strontium titanate (BST) thin films prepared by pulsed laser deposition technique JF - Physica Status Solidi (A) N2 - pH-sensitive properties of barium strontium titanate (BST) high-k thin films as alternative gate material for field-effect capacitive (bio-)chemical sensors based on an electrolyte-insulator-semiconductor system have been investigated. The BST films of different compositions (Ba0.31Sr0.69TiO3, Ba0.25Sr0.75TiO3 and Mg-doped Ba0.8Sr0.2Mg0.1Ti0.9O3) were deposited by pulsed laser deposition technique from targets fabricated by self-propagating high-temperature synthesis. The realised sensors have been electrochemically characterised by means of impedance-spectroscopy, capacitance–voltage and constant-capacitance method. The sensors possess a Nernstian-like pH sensitivity in the concentration range between pH 3 and 11 with a response time of 5–10 s. An equivalent circuit model for the BST-based capacitive field-effect sensor is discussed. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983310 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 824 EP - 830 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Turek, Monik A1 - Heiden, Wolfgang A1 - Guo, Sharon A1 - Riesen, Alfred A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Simultaneous detection of cyanide and heavy metals for environmental analysis by means of µISEs JF - Physica Status Solidi (A) N2 - In environmental analysis, cyanide and heavy metals play an important role, because these substances are highly toxic for biological systems. They can lead to chronic and acute diseases. Due to the chemical properties of cyanide it is frequently used for industrial processes such as extraction of silver and gold. Heavy metals can be found as trace elements in nature and are often applied in industries e.g., galvanization processes. Up to now, cyanide and heavy metals can be detected by several sensors separately and their detection is often limited to laboratory investigations. In this publication, with regard to an in situ analysis, a new miniaturized silicon-based sensor system for the simultaneous detection of cyanide and heavy metals in aqueous solutions is presented that is based on chalcogenide glass-based micro ion-selective electrodes (µISEs). The µISEs are incorporated into a specially designed measuring system for the simultaneous detection of heavy metals and cyanide in solutions and validated by simultaneous measurements of Cu2+- and CN−-ions, Cd2+- and CN−- ions and Pb2+- and CN−-ions. The particular sensor system has shown good sensor properties in the µ-molar ion-concentration range. For simultaneous measurements in complex heavy metal and cyanide solutions an intelligent software using fuzzy logic is discussed. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983303 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 817 EP - 823 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Jansen, S. V. A1 - Behbahani, Mehdi A1 - Laumen, M. A1 - Kaufmann, T. A1 - Hormes, M. A1 - Behr, Marek A1 - Schmitz-Rode, T. A1 - Steinseifer, U. T1 - Investigation of Steady Flow Through a Realistic Model of the Thoracic Human Aorta Using 3D Stereo PIV and CFD-Simulation JF - ASAIO Journal Y1 - 2010 U6 - https://doi.org/10.1097/01.mat.0000369377.65122.a3 N1 - American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 VL - 56 IS - 2 SP - 98 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Probst, M. A1 - Mai, A. A1 - Tran, L. A1 - Vonderstein, K. A1 - Keschenau, P. A1 - Linde, T. A1 - Steinseifer, U. A1 - Behr, Marek A1 - Mottaghy, K. T1 - The influence of high shear on thrombosis and hemolysis in artificial organs JF - The International Journal of Artificial Organs Y1 - 2010 SN - 0391-3988 VL - 33 IS - 7 SP - 426 EP - 426 PB - Sage CY - Thousand Oaks ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Nam, J. A1 - Waluga, C. A1 - Behr, Marek A1 - Pasquali, M. A1 - Mottaghy, K. T1 - Modeling and Numerical Analysis of Platelet Activation, Adhesion and Aggregation in Artificial Organs Y1 - 2010 U6 - https://doi.org/10.1097/01.mat.0000369377.65122.a3 N1 - Posterpresentation American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 VL - 56 IS - 2 SP - 85 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Beckers, Leah A1 - Schaub, A. A1 - Zander, W. A1 - Schubert, J. A1 - Mesters, S. A1 - Kordos, P. A1 - Lüth, H. T1 - A novel silicon-based pH sensor prepared by pulsed laser deposition technique JF - Proceedings of Eurosensors X, the 10th European Conference on Solid-State Transducers, September 8-11, 1996, Leuven, Belgium / [KU Leuven]. Puers, Robert. Vol. 3. Y1 - 1996 SN - 90-803282-1-9 N1 - Eurosensors ; (10, 1996, Louvain) Eurosensors, the European Conference on Solid-State Transducers ; (10 : ; 1996.09.08-11 : ; Leuven) SP - 781 EP - 784 PB - Catholic University Leuven CY - Heverlee, Belgium ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Mai, A. A1 - Waluga, C. A1 - Bergmann, B. A1 - Tran, L. A1 - Vonderstein, K. A1 - Behr, Marek A1 - Mottaghy, K. T1 - Numerical Modeling of Flow-Related Thrombus Formation under Physiological and Non-Physiological Flow Conditions JF - Acta Physiologica Y1 - 2010 SN - 1748-1716 N1 - Joint Congress of the Scandinavian and German Physiological Societies, Copenhagen, Denmark, March 27-30, 2010 VL - 198 IS - Supplement 677 SP - 185 ER - TY - JOUR A1 - Siqueira, José R. Jr. A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Associating biosensing properties with the morphological structure of multilayers containing carbon nanotubes on field-effect devices JF - Physica Status Solidi (A) N2 - The control of molecular architecture provided by the layer-by-layer (LbL) technique has led to enhanced biosensors, in which advantageous features of distinct materials can be combined. Full optimization of biosensing performance, however, is only reached if the film morphology is suitable for the principle of detection of a specific biosensor. In this paper, we report a detailed morphology analysis of LbL films made with alternating layers of single-walled carbon nanotubes (SWNTs) and polyamidoamine (PAMAM) dendrimers, which were then covered with a layer of penicillinase (PEN). An optimized performance to detect penicillin G was obtained with 6-bilayer SWNT/PAMAM LbL films deposited on p-Si-SiO2-Ta2O5 chips, used in biosensors based on a capacitive electrolyte-insulator-semiconductor (EIS) and a light-addressable potentiometric sensor (LAPS) structure, respectively. Field-emission scanning electron microscopy (FESEM) and atomic force microscopy (AFM) images indicated that the LbL films were porous, with a large surface area due to interconnection of SWNT into PAMAM layers. This morphology was instrumental for the adsorption of a larger quantity of PEN, with the resulting LbL film being highly stable. The experiments to detect penicillin were performed with constant-capacitance (ConCap) and constant-current (CC) measurements for EIS and LAPS sensors, respectively, which revealed an enhanced detection signal and sensitivity of ca. 100 mV/decade for the field-effect sensors modified with the PAMAM/SWNT LbL film. It is concluded that controlling film morphology is essential for an enhanced performance of biosensors, not only in terms of sensitivity but also stability and response time. Y1 - 2010 U6 - https://doi.org/10.1002/pssa.200983301 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 VL - 207 IS - 4 SP - 781 EP - 786 PB - Wiley-VCH CY - Berlin ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Reisert, Steffen A1 - Schubert, J. A1 - Zander, W. A1 - Begoyan, Vardges K. A1 - Buniatyan, V. V. A1 - Schöning, Michael Josef T1 - Chemical sensors based on a high-k perovskite oxide of barium strontium titanate JF - Procedia Engineering N2 - High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors for liquids. In this work, BST films have been applied as a sensitive transducer material for a label-free detection of adsorbed charged macromolecules (positively charged polyelectrolytes) and concentration of hydrogen peroxide vapor as well as protection insulator layer for a contactless electrolyte-conductivity sensor. The experimental results of characterization of individual sensors are presented. Special emphasis is devoted towards the development of a capacitively-coupled contactless electrolyte-conductivity sensor. KW - barium strontium titanate KW - high-k material KW - contactless conductivity sensor KW - multi-functional material KW - hydrogen peroxide Y1 - 2014 U6 - https://doi.org/10.1016/j.proeng.2014.11.258 SN - 1877-7058 N1 - EUROSENSORS 2014 ; European Conference on Solid-State Transducers <28, 2014> VL - 87 SP - 28 EP - 31 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Tran, L. A1 - Waluga, C. A1 - Behr, Marek A1 - Oedekoven, B. A1 - Mottaghy, K. T1 - Model-based Numerical Analysis of Platelet Adhesion, Thrombus Growth and Aggregation for Assist Devices JF - The International Journal of Artificial Organs. 32 (2009), H. 7 Y1 - 2009 SN - 0391-3988 N1 - Abstracts - Oral Presentations: XXXVI Annual ESAO Congress, 2-5 September 2009, Compiègne - France; European Society of Artificial Organs (ESAO), Compiegne, France, September 2-5, 2009 SP - 398 EP - 398 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schaub, A. A1 - Zundel, A. A1 - Beckers, Leah A1 - Schubert, J. A1 - Zander, W. A1 - Kordos, P. A1 - Lüth, H. T1 - Pulsed laser deposition as a novel thin film preparation method for silicon-based field effect sensors JF - Proceedings of the 25th European Solid State Device Research Conference : the Netherlands Congress Centre, The Hague, the Netherlands, 25th - 27th September 1995 / ESSDERC '95. Ed. by H. C. de Graaff Y1 - 1995 SN - 2-86332-182-X N1 - ESSDERC ; (25, 1995, 's-Gravenhage) ; European Solid State Device Research Conference (ESSDERC) ; (25 : ; 1995.09.25-27 : ; Den Haag) SP - 601 EP - 604 PB - Ed. Frontières CY - Gif-sur-Yvette ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Behr, Marek A1 - Arora, D. A1 - Coronado, O. A1 - Pasquali, M. T1 - CFD Analysis of MicroMed Debakey Pump and Hemolysis Prediction / Behbahani, M. ; Behr, M. ; Arora, D. ; Coronado, O. ; Pasquali, M. JF - Artificial Organs. 30 (2006), H. 11 Y1 - 2006 SN - 1525-1594 N1 - Abstracts 14th Congress of the International Society for Rotary Blood Pumps, Leuven, Belgium, August 31–September 2, 2006 ; S7-4 SP - A45 EP - A46 ER -