TY - JOUR A1 - Öhlschläger, Peter A1 - Pes, Michaela A1 - Osen, Wolfram A1 - Dürst, Matthias T1 - An improved rearranged Human Papillomavirus Type 16 E7 DNA vaccine candidate (HPV-16 E7SH) induces an E7 wildtype-specific T cell response / Öhlschläger, Peter ; Pes, Michaela ; Osen, Wolfram ; Dürst, Matthias ; Schneider, Achim ; Gissmann, Lutz ; Kaufman JF - Vaccine. 24 (2006), H. 15 Y1 - 2006 SN - 0264-410X SP - 2880 EP - 2893 ER - TY - JOUR A1 - Öhlschläger, Peter A1 - Michel, Nico A1 - Osen, Wolfram A1 - Freyschmidt, Eva-Jasmin T1 - T cell response to human papillomavirus 16 E7 in mice: comparison of Cr release assay, intracellular IFN-gamma production, ELISPOT and tetramer staining / Michel, Nico ; Öhlschläger, Peter ; Osen, Wolfram ; Freyschmidt, Eva-Jasmin ; Gutöhrlein, Heidrun ; JF - Intervirology. 45 (2002) Y1 - 2002 SN - 1423-0100 SP - 290 EP - 299 ER - TY - JOUR A1 - Öhlschläger, Peter A1 - Osen, Wolfram A1 - Dell, Kerstin A1 - Faath, Stefan T1 - Human papillomavirus type 16 L1 capsomeres induce L1-specific cytotoxic T lymphocytes and tumor regression in C57BL/6 mice / Öhlschläger, Peter ; Osen, Wolfram ; Dell, Kerstin ; Faath, Stefan ; Garcea Robert L: ; Jochmus, Ingrid ; Müller, Martin, Pawlita, JF - Journal of Virology. 77 (2003), H. 8 Y1 - 2003 SN - 1098-5514 SP - 4635 EP - 4645 ER - TY - JOUR A1 - Hartung, Frank A1 - Rey, J. A1 - Mathieu, B. A1 - Lozano, D. T1 - Media aware overlay routing in Ambient Networks / Rey, J. ; Mathieu, B. ; Lozano, D. ; Herborn, S. ; Ahmed, K. ; Schmid, S. ; Goebbels, S. ; Hartung, F. ; Kampmann, M. JF - 16th IEEE International Symposium on Personal, Indoor and Mobile Radio Communications, 2005. PIMRC 2005. Date:11-14 Sept. 2005 ; Vol. 2 Y1 - 2004 SP - 952 EP - 957 ER - TY - JOUR A1 - Hartung, Frank A1 - Kumwilaisak, W. T1 - An intraframe error concealment: nonlinear pattern alignment and directional interpolation / Kumwilaisak, W. ; Hartung, F. JF - Conference on Image Processing, 2004. ICIP '04. 2004 International / Vol. 2 . Y1 - 2004 N1 - http://dx.doi.org/10.1109/ICIP.2004.1419426 SP - 825 EP - 828 ER - TY - JOUR A1 - Aggarwal, Prerna A1 - Singh, Virendra A1 - Singh, Arjun A1 - Scherer, Ulrich W. A1 - Singh, Tejvir A1 - Singla, Madan L. A1 - Srivastava, Alok T1 - Physico-chemical transformations in swift heavy ion modified poly(ethyleneterephthalate) JF - Radiation Physics and Chemistry Y1 - 2011 SN - 0969-806X N1 - In Press, Accepted Manuscript SP - 1 EP - 28 PB - Pergamon Press CY - Oxford ER - TY - JOUR A1 - Wagner, Torsten A1 - Miyamoto, Ko-ichiro A1 - Shigihara, Noriko A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Microfluidic systems with free definable sensor spots by an integrated light-addressable potentiometric sensor JF - Procedia Engineering. 25 (2011) Y1 - 2011 SN - 1877-7058 N1 - EurosensorsXXV ; Proc. Eurosensors XXV, September 4-7, 2011, Athens, Greece SP - 791 EP - 794 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bohrn, U. A1 - Stütz, E. A1 - Fuchs, K. A1 - Fleischer, M. A1 - Schöning, Michael Josef A1 - Wagner, P. T1 - Air Quality Monitoring using a Whole-Cell based Sensor System JF - Procedia Engineering. 25 (2011) Y1 - 2011 SN - 1877-7058 N1 - EurosensorsXXV ; Proc. Eurosensors XXV, September 4-7, 2011, Athens, Greece SP - 1421 EP - 1424 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hartung, Frank A1 - Noh, Jeonghun A1 - Baccichet, Pierpaolo A1 - Mavlankar, Aditya T1 - Standford Peer-to-Peer Mulicast (SPPM) - Overview and recent Extensions / Noh, Jeonghun ; Baccichet, Pierpaolo ; Hartung, Frank ; Mavlankar, Aditya ; Girod, Bernd Y1 - 2009 SN - 978-1-4244-4593-6 N1 - Picture Coding Symposium, 2009. PCS 2009 ; auch unter IEEE: http://dx.doi.org/10.1109/PCS.2009.5167392 SP - 1 EP - 4 ER - TY - JOUR A1 - Hartung, Frank A1 - Horn, Uwe A1 - Huschke, Jörg A1 - Kampmann, Markus T1 - MBMS—IP Multicast/Broadcast in 3G Networks / Hartung, Frank ; Horn, Uwe ; Huschke, Jörg ; Kampmann, Markus ; Lohmar, Thorsten JF - International Journal of Digital Multimedia Broadcasting. 2009 (2009) Y1 - 2009 SN - 1687-7586 N1 - Article ID 597848 SP - 1 EP - 25 ER - TY - JOUR A1 - Hartung, Frank A1 - Kampmann, Markus A1 - Horn, Uwe A1 - Kritzner, Jan T1 - Mobile Television / Hartung, Frank ; Kampmann, Markus ; Horn, Uwe ; Kritzner, Jan JF - Encyclopedia of mobile computing and commerce / David Taniar ; Bd. 2 : Mobile ICT - Z Y1 - 2007 SN - 978-1-59904-002-8 SP - 611 EP - 615 PB - Information Science Reference CY - Hershey ER - TY - JOUR A1 - Hartung, Frank A1 - Horn, Uwe A1 - Huschke, Jörg A1 - Kampmann, Markus T1 - Delivery of Broadcast Services in 3G Networks / Hartung, Frank ; Horn, Uwe ; Jörg Huschke ; Kampmann, Markus ; Lohmar, Thorsten ; Lundevall, Magnus JF - IEEE Transactions on Broastcasting. 53 (2007), H. 1 Part: 2 Y1 - 2007 SN - 0018-9316 N1 - campusweit: http://dx.doi.org/10.1109/TBC.2007.891711 SP - 188 EP - 199 ER - TY - JOUR A1 - Hartung, Frank A1 - Horn, Uwe A1 - Huschke, Jörg A1 - Kampmann, Markus T1 - Mobile TV Services in 3G Networks / Hartung, Frank ; Horn, Uwe ; Huschke, Jörg ; Kampmann, Markus ; Lohmar, Thorsten JF - KIVS 2007 : Kommunikation in verteilten Systemen : 15. ITG-GI-Fachtagung vom 26. Februar bis 2. März 2007 in Bern, Schweiz ; Industriebeiträge, Kurzbeiträge und Workshops / T. Braun ... (Hrsg.) Y1 - 2007 SN - 978-3-8007-2980-7 N1 - Communication in Distributed Systems (KiVS), 2007 ITG-GI Conference SP - 15 EP - 18 ER - TY - JOUR A1 - Hartung, Frank A1 - Kampmann, Markus T1 - Media Delivery Based on Service Aware Transport Overlay Networks / Kampmann, Markus ; Hartung, Frank JF - KIVS 2007 : Kommunikation in verteilten Systemen : 15. ITG-GI-Fachtagung vom 26. Februar bis 2. März 2007 in Bern, Schweiz ; Industriebeiträge, Kurzbeiträge und Workshops / T. Braun ... (Hrsg.) Y1 - 2007 SN - 978-3-8007-2980-7 N1 - Communication in Distributed Systems (KiVS), 2007 ITG-GI Conference SP - 9 EP - 10 ER - TY - JOUR A1 - Hartung, Frank A1 - Kampmann, M. A1 - Horn, U. A1 - Huschke, J. T1 - Delivery of Mobile TV services in 3G cellular networks / Kampmann, M. ; Hartung, F. ; Horn, U. ; Huschke, J. ; Lohmar, T. JF - Elektronische Medien : Vorträge des 12. Dortmunder Fernsehseminars vom 20. bis 21. März 2007 in Dortmund / Veranst.: ITG-FKTG-Fachbereich 3 ... Wiss. Tagungsleitung: R. Kays Y1 - 2007 SN - 978-3-8007-3019-3 N1 - ITG-Fachbericht ; 199 SP - 49 EP - 52 PB - VDE-Verl. CY - Berlin ER - TY - JOUR A1 - Hartung, Frank A1 - Dondeti, L. A1 - Castleford, F. T1 - Multimedia Internet KEYing (MIKEY) General Extension Payload for Open Mobile Alliance BCAST LTKM/STKM Transport / Dondeti, L. ; Castleford, D. ; Hartung, F. Y1 - 2007 SP - 1 EP - 7 ER - TY - JOUR A1 - Hartung, Frank A1 - Schieder, Andreas A1 - Kampmann, Markus A1 - Vorwerk, Marc T1 - Network Supported Media Delivery in Ambient Networks (Netzwerkunterstützte Medienverteilung) / Schieder, Andreas ; Kampmann, Markus ; Hartung, Frank ; Vorwerk, Marc ; Rembarz, René JF - it - Information Technology . 48 (2006), H. 5 Y1 - 2006 SN - 1611-2776 N1 - in der Bereichsbibliothek Eupener Str. unter der Signatur 23 Z 376 vorhanden SP - 264 EP - 273 ER - TY - JOUR A1 - Hartung, Frank A1 - Baldo, N. A1 - Horn, U. A1 - Kampmann, M. T1 - RTCP feedback based transmission rate control for 3G wireless multimedia streaming / Baldo, N. ; Horn, U. ; Kampmann, M. ; Hartung, F. ; JF - 15th IEEE International Symposium on Personal, Indoor and Mobile Radio Communications, 2004. PIMRC 2004. Date:5-8 Sept. 2004 ; Vol. 3 Y1 - 2004 N1 - http://dx.doi.org/10.1109/PIMRC.2004.1368313 SP - 1817 EP - 1821 ER - TY - JOUR A1 - Bohn, D. A1 - Funke, Harald A1 - Gier, J. T1 - Numerical and Experimental Investigations on the Flow in a 4-Stage Turbine with Special Focus on the Development of a Radial Temperature Streak JF - ASME Turbo Expo 1999, Indianapolis, USA, 1999 Y1 - 1999 N1 - ASME-Paper 99-GT-027 ER - TY - JOUR A1 - Funke, Harald A1 - Recker, E. A1 - Bosschaerts, W. A1 - Boonen, Q. A1 - Börner, Sebastian T1 - Parametrical study of the „Micromix“ hydrogen combustion principle JF - 10th International Symposium on Experimental and Computational Aerothermodynamics of Internal Flows, ISAIF10-049, Brussels, Belgium, 4-7 July 2011 Y1 - 2011 ER - TY - JOUR A1 - Funke, Harald A1 - Börner, Sebastian A1 - Robinson, A. A1 - Hendrick, P. A1 - Recker, E. T1 - Low NOx H2 combustion for industrial gas turbines of various power ranges JF - 5th International Gas Turbine Conference ETN-IGTC, ETN-2010-42, Brussels, Belgium, October 2010 Y1 - 2010 ER - TY - CHAP A1 - Funke, Harald A1 - Börner, Sebastian A1 - Hendrick, P. A1 - Recker, E. A1 - Elsing, R. ED - DeLuca, Luigi T. T1 - Development and integration of a scalable low NOx combustion chamber for a hydrogen fuelled aero gas turbine T2 - Progress in Propulsion Physics. - Vol. 4 Y1 - 2013 SN - 978-2-7598-0876-2 U6 - https://doi.org/10.1051/eucass/201304357 N1 - 4th European Conference for Aero-Space Sciences : July 4 - 8, 2011, St Petersburg, Russia ; EUCASS <4, 2011, St. Petersburg> SP - 357 EP - 372 PB - EDP Sciences CY - [Les Ulis] ER - TY - JOUR A1 - Esch, Thomas A1 - Funke, Harald A1 - Roosen, Peter A1 - Jarolimek, Ulrich T1 - Biogenic Vehicle Fuels in General Aviation Aircrafts JF - MTZ worldwide. 72 (2011), H. 1 Y1 - 2011 N1 - recherchierbar für Angehörige der FH Aachen SP - 38 EP - 43 PB - Springer Automotive Media CY - Wiesbaden ER - TY - JOUR A1 - Recker, Elmar A1 - Bosschaerts, Walter A1 - Wagemakers, Rolf A1 - Hendrick, Patrick A1 - Funke, Harald A1 - Börner, Sebastian T1 - Experimental study of a round jet in cross-flow at low momentum ratio JF - 15th International Symposium on Applications of Laser Techniques to Fluid Mechanics Lisbon, Portugal, 05-08 July, 2010 - 1 Y1 - 2010 SP - 1 EP - 13 ER - TY - JOUR A1 - Bécret, P. A1 - Grossen, J. A1 - Trilla, J. A1 - Robinson, A. A1 - Bosschaerts, W. A1 - Funke, Harald A1 - Hendrick, P. T1 - Testing and numerical study of a 10 kW hydrogen micro combustor JF - International Workshop on Micro and Nanotechnology for Power Generation and Energy Conversion Applications <7, 2007, Freiburg, Breisgau> ; PowerMEMS ; 7 Y1 - 2007 SP - 367 EP - 370 ER - TY - JOUR A1 - Robinson, A. E. A1 - Rönna, Uwe A1 - Funke, Harald T1 - Testing of a 10 kW diffusive micro-mix combustor for hydrogen-fuelled micro-scale gas turbines JF - International Workshop on Micro and Nanotechnology for Power Generation and Energy Conversion Applications <7, 2007, Freiburg, Breisgau> ; PowerMEMS ; 7 Y1 - 2007 SP - 225 EP - 228 ER - TY - JOUR A1 - Funke, Harald A1 - Börner, Sebastian A1 - Falk, F. A1 - Hendrick, P. T1 - Control system modifications and their effects on the operation of a hydrogen-fueled Auxiliary Power Unit JF - XX international symposium on air breathing engines 2011 : ISABE 2011, Gothenburg, Sweden, 12-16 September, 2011. Vol. 2. Y1 - 2011 SN - 9781618391803 N1 - 20th International Symposium on Air Breathing Engines 2011 : (ISABE 2011) : Gothenburg, Sweden, 12-16 September, 2011. SP - 929 EP - 938 PB - American Institute of Aeronautics and Astronautics CY - Reston, VA ER - TY - JOUR A1 - Werner, Frederik A1 - Wagner, Torsten A1 - Miyamoto, Ko-ichiro A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - High speed and high resolution chemical imaging based on a new type of OLED-LAPS set-up JF - Procedia Engineering. 25 (2011) Y1 - 2011 SN - 1877-7058 N1 - EurosensorsXXV ; Proc. Eurosensors XXV, September 4-7, 2011, Athens, Greece SP - 346 EP - 349 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Funke, Harald A1 - Robinson, A. E. A1 - Hendrick, P. A1 - Wagemakers, R. T1 - Design and Testing of a Micromix Combustor With Recuperative Wall Cooling for a Hydrogen Fuelled µ-Scale Gas Turbine JF - Proceedings of the ASME Turbo Expo 2010 : presented at the 2010 ASME Turbo Expo, June 14 - 18, 2010, Glasgow, UK / sponsored by the International Gas Turbine Institute / Vol. 5: Industrial and cogeneration ; microturbines and small turbomachinery ; oil and gas applications ; wind turbine technology Y1 - 2010 SN - 978-0-7918-4400-7 N1 - GT2010-23453 ; ASME Turbo Expo ; (Glasgow) : 2010.06.14-18 SP - 587 EP - 596 PB - ASME CY - New York, NY ER - TY - JOUR A1 - Robinson, A. E. A1 - Funke, Harald A1 - Wagemakers, R. A1 - Grossen, J. A1 - Bosschaerts, W. A1 - Hendrick, P. T1 - Numerical and Experimental Investigation of a Micromix Combustor for a Hydrogen Fuelled μ-Scale Gas Turbine JF - Proceedings of the ASME Turbo Expo 2009 : : presented at the 2009 ASME Turbo Expo, June 8 - 12, 2009, Orlando, Florida, USA / sponsored by the International Gas Turbine Institute Y1 - 2009 SN - 9780791848869 N1 - GT2009-60061 SP - 253 EP - 262 PB - ASME CY - New York, NY ER - TY - JOUR A1 - Bohn, D. A1 - Funke, Harald A1 - Gier, J. T1 - Temperature jet development in a cross-over channel JF - Third European Conference on Turbomachinery - fluid dynamics and thermodynamics : : 2 - 5 March 1999, Royal National Hotel, London, UK / organized by the Energy Transfer and Thermofluid Mechanics Group of the Institution of Mechanical Engineers (IMechE); with support and sponsorship from European Commission / Vol. B. Y1 - 1999 N1 - C557/158/99 ; IMechE conference transactions 1999-1B SP - 671 EP - 680 PB - Professional Engineering Publ. CY - Bury St. Edmunds ER - TY - JOUR A1 - Bohn, Dieter A1 - Funke, Harald A1 - Heuer, Tom A1 - Bütikofer, J. T1 - Numerical and experimental investigations of the influence of different swirl-ratios on the temperature streak equalization in a 4-stage turbine JF - ASME Turbo Expo 2000 ; Munich, May 8-11 2000 Y1 - 2000 N1 - ASME-paper ; 2000-GT-250 CY - Munich ER - TY - JOUR A1 - Bohn, Dieter A1 - Funke, Harald A1 - Sürken, Norbert A1 - Kreitmeier, F. T1 - Numerical and experimental investigations on endwall contouring in a four-stage turbine JF - ASME Turbo Expo Land Sea & Air 2001 : June 4 - 8, 2001, New Orleans, Louisiana / IGTI, International Gas Turbine Institute. American Society of Mechanical Engineers. International Gas Turbine Institute .. Y1 - 2001 SN - 0-7918-3528-6 N1 - ASME-Paper 2001-GT-0481 PB - ASME CY - New York, NY ER - TY - JOUR A1 - Funke, Harald A1 - Rönna, Uwe A1 - Robinson, A. E. T1 - Development and testing of a 10 kW diffusive micromix combustor for hydrogen-fuelled μ-scale gas turbines JF - Proceedings of ASME Turbo Expo 2008: Power for Land, Sea and Air ; GT2008 ; June 9-13, 2008, Berlin, Germany Y1 - 2008 N1 - GT2008-50418 SP - 1 EP - 8 PB - ASME CY - New York, NY ER - TY - JOUR A1 - Funke, Harald A1 - Börner, Sebastian A1 - Krebs, W. A1 - Wolf, E. T1 - Experimental Characterization of Low NOx Micromix Prototype Combustors for Industrial Gas Turbine Applications JF - ASME Turbo Expo 2011 ; Vancouver, Canada, June 6-10, 2011 Y1 - 2011 N1 - GT2011-45305 ER - TY - JOUR A1 - Hartung, Frank A1 - Girod, Bernd A1 - Horn, Uwe T1 - Subband Image Coding / Girod, Bernd ; Hartung, Frank ; Horn, Uwe JF - Subband and Wavelet Transforms: Design and Applications / ed. by Ali N. Akansu Y1 - 1995 SN - 0792396456 SP - 213 EP - 250 PB - Kluwer CY - Boston ER - TY - JOUR A1 - Hartung, Frank T1 - Mobile DRM Introduction: The Need for Mobile DRM JF - Digital Rights Management : Technological, Economic, Legal and Political Aspects / Becker, Eberhard [u.a.] Y1 - 2003 N1 - Lecture Notes in Computer Science ; 2770 SP - 138 EP - 149 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hartung, Frank A1 - Girod, Bernd T1 - Copyright protection in video delivery networks by watermarking of pre-compressed video / Hartung, Frank ; Girod, Bernd JF - Multimedia Applications, Services and Techniques - EMAST ´97 : Second European Conference Milan, Italy, May 21-23, 1997 Proceedings / Fdida, Serge ; Morganti, Michele Y1 - 1997 N1 - Lecture Notes in Computer Science ; 1242 SP - 423 EP - 436 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hartung, Frank A1 - Ramme, F. T1 - Digital rights management and watermarking of multimedia content for m-commerce applications / Hartung, F. ; Ramme, F. JF - IEEE Communications Magazine. 38 (2000), H. 11 Y1 - 2000 SN - 0163-6804 N1 - ISS 2000 SP - 78 EP - 84 ER - TY - JOUR A1 - Hartung, Frank A1 - Girod, Bernd T1 - Statistical optimization of switched two-level quantizers with application to DPCM encoding of color video / Hartung, Frank ; Girod, Bernd JF - IEEE International Conference on Acoustics, Speech, and Signal Processing, 1996. ICASSP-96. Conference Proceedings., 1996 Y1 - 1996 SN - 0-7803-3192-3 SP - 1974 EP - 1977 ER - TY - JOUR A1 - Hartung, Frank A1 - Niebert, Norbert A1 - Schieder, Andreas A1 - Rembarz, René T1 - Advances in network-supported media delivery in next-generation mobile systems / Hartung, Frank ; Niebert, Norbert ; Schieder, Andreas ; Rembarz, René ; Schmid, Stefan ; Eggert, Lars JF - IEEE Communications Magazine. 44 (2006), H. 8 Y1 - 2006 SN - 0163-6804 SP - 82 EP - 89 ER - TY - JOUR A1 - Hamm, Laurits A1 - Hartung, Frank T1 - High Quality Visual Communication based on IMS JF - Mobilkommunikation : Technologien und Anwendungen ; Vorträge der 16. ITG-Fachtagung vom 18. bis 19. Mai 2011 in Osnabrück / Veranst.: Informationstechnische Gesellschaft im VDE (ITG) ... Tagungsleitung: Ralf Tönjes. Programmkomitee/Hrsg.: Peter Roer Y1 - 2011 SN - 978-3-8007-3352-1 N1 - ITG-Fachbericht ; 230 ; Fachtagung Mobilkommunikation <16, 2011, Osnabrück> SP - 80 EP - 85 PB - VDE-Verl. CY - Berlin ER - TY - JOUR A1 - Hartung, Frank A1 - Kesici, Sinan A1 - Catrein, Daniel T1 - DRM protected Dynamic Adaptive HTTP Streaming JF - Proceedings of the 2011 ACM Multimedia Systems Conference [Elektronische Ressource] : February 23 - 25, 2011, San Jose, CA, USA / sponsored by: ACM SIGMM Y1 - 2011 SN - 9781450305181 N1 - ACM Multimedia Systems Conference ; (2 : ; 2011.02.23-25 : ; San Jose, Calif.) SP - 277 EP - 282 PB - ACM CY - New York, NY ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Koshitz, I. N. A1 - Svetlowa, O. V. A1 - Zaseeva, M. V. T1 - Physiological principles of hypotensive therapy of open-angle glaucoma during presbyopic period. Part II Promising algorithms of practical sparing applications / Koshitz, I. N. ; Svetlova, O. V. ; Zaseeva, M. V. ; Shuhaev, S. V. ; Makarov, F. N. ; Kotliar JF - Glaukoma (2006) Y1 - 2006 N1 - Original in Russisch SP - 51 EP - 70 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Koshitz, I. N. A1 - Svetlowa, O. V. A1 - Makarov, F. N. T1 - Biomechanical analysis of traditional and contemporary conceptions on pathogenesis of the primary open angle glaucoma / Koshitz, I. N. ; Svetlova, O. V. ; Kotliar, K. E. ; Makarov, F. N. ; Smolnikov, B. A. JF - Glaukoma (2005) Y1 - 2005 N1 - Original in Russisch SP - 41 EP - 63 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Svetlova, O. V. A1 - Stegaev, V. A. A1 - Parkhomov, S. D. T1 - Biomechanical substantiation of relatively low efficiency of recurrent laser trabeculoplasty / Svetlova, O. V. ; Stagaev, V. A. ; Parkhomov, S. D. ; Kotliar, K. E. ; Makarov, F. N. ; Smolnikov, B. A. ; Koshitz, I. N. JF - Glaukoma (2004) Y1 - 2004 N1 - Original in Russisch SP - 29 EP - 39 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Svetlova, O. V. A1 - Sourjikov, A. V. A1 - Zaseeva, M. V. T1 - Biomechanical peculiarities of aqueous humor production system and outflow regulation system / Svetlova, O. V. ; Sourjikov, A. V. ; Kotliar, K. E. ; Zaseeva, M. V. ; Shukhaev, S. V. ; Koshitz, I. N. JF - Glaukoma (2004) Y1 - 2004 N1 - Original in Russisch SP - 66 EP - 76 PB - - ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Kaneko, Kazumi A1 - Matsuo, Akira A1 - Wagner, Torsten A1 - Kanoh, Shiníchiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Miniaturized chemical imaging sensor system using an OLED display panel JF - Sensors and Actuators B: Chemical N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the two-dimensional distribution of specific ions or molecules in the solution. In this study, we developed a miniaturized chemical imaging sensor system with an OLED display panel as a light source that scans the sensor plate. In the proposed configuration, the display panel is placed directly below the sensor plate and illuminates the back surface. The measured area defined by illumination can be arbitrarily customized to fit the size and the shape of the sample to be measured. The waveform of the generated photocurrent, the current–voltage characteristics and the pH sensitivity were investigated and pH imaging with this miniaturized system was demonstrated. KW - LAPS KW - Light-addressable potentiometric sensor KW - Chemical imaging sensor KW - Organic light-emitting diode display Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2011.02.029 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 82 EP - 87 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Rysstad, Gunnar A1 - Schöning, Michael Josef A1 - Keusgen, Michael T1 - Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Sensors and Actuators B: Chemical N2 - A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(%, v/v) in a H2O2 concentration range of 0%, v/v to 8%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes. KW - Sterilisation process KW - Hydrogen peroxide KW - Polyimide KW - Calorimetric gas sensor Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2011.01.032 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 60 EP - 66 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Atlas, Glen A1 - Brealey, David A1 - Dhar, Sunil A1 - Dikta, Gerhard A1 - Singer, Meryvn T1 - Additional hemodynamic measurements with an esophageal Doppler monitor: a preliminary report of compliance, force, kinetic energy, and afterload in the clinical setting JF - Journal of clinical monitoring and computing N2 - The esophageal Doppler monitor (EDM) is a minimally-invasive hemodynamic device which evaluates both cardiac output (CO), and fluid status, by estimating stroke volume (SV) and calculating heart rate (HR). The measurement of these parameters is based upon a continuous and accurate approximation of distal thoracic aortic blood flow. Furthermore, the peak velocity (PV) and mean acceleration (MA), of aortic blood flow at this anatomic location, are also determined by the EDM. The purpose of this preliminary report is to examine additional clinical hemodynamic calculations of: compliance (C), kinetic energy (KE), force (F), and afterload (TSVRi). These data were derived using both velocity-based measurements, provided by the EDM, as well as other contemporaneous physiologic parameters. Data were obtained from anesthetized patients undergoing surgery or who were in a critical care unit. A graphical inspection of these measurements is presented and discussed with respect to each patient’s clinical situation. When normalized to each of their initial values, F and KE both consistently demonstrated more discriminative power than either PV or MA. The EDM offers additional applications for hemodynamic monitoring. Further research regarding the accuracy, utility, and limitations of these parameters is therefore indicated. KW - Acceleration KW - Velocity KW - Kinetic energy KW - Force KW - Compliance KW - Afterload KW - Contractility KW - Volume status KW - Esophageal Doppler monitor Y1 - 2012 SN - 1573-2614 U6 - https://doi.org/10.1007/s10877-012-9386-5 IS - 26 SP - 473 EP - 482 PB - Springer Nature CY - London ER - TY - BOOK A1 - Artmann, Gerhard T1 - Stem cell engineering : principles and applications / Gerhard M. Artmann ... eds. Y1 - 2011 SN - 978-3-642-11864-7 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Iken, Heiko A1 - Kirsanov, D. A1 - Legin, A. A1 - Schöning, Michael Josef T1 - Novel Thin-Film Polymeric Materials for the Detection of Heavy Metals JF - Procedia Engineering N2 - A variety of transition metals, e.g., copper, zinc, cadmium, lead, etc. are widely used in industry as components for wires, coatings, alloys, batteries, paints and so on. The inevitable presence of transition metals in industrial processes implies the ambition of developing a proper analytical technique for their adequate monitoring. Most of these elements, especially lead and cadmium, are acutely toxic for biological organisms. Quantitative determination of these metals at low activity levels in different environmental and industrial samples is therefore a vital task. A promising approach to achieve an at-side or on-line monitoring on a miniaturized and cost efficient way is the combination of a common potentiometric sensor array with heavy metal-sensitive thin-film materials, like chalcogenide glasses and polymeric materials, respectively. Y1 - 2012 U6 - https://doi.org/10.1016/j.proeng.2012.09.148 SN - 1877-7058 N1 - Part of special issue "26th European Conference on Solid-State Transducers, EUROSENSOR 2012" IS - 47 SP - 322 EP - 325 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Miyamoto, K. A1 - Ichimura, H. A1 - Wagner, Torsten A1 - Yoshinobu, T. A1 - Schöning, Michael Josef T1 - Chemical Imaging of ion Diffusion in a Microfluidic Channel JF - Procedia Engineering N2 - The chemical imaging sensor is a chemical sensor which is capable of visualizing the spatial distribution of chemical species in sample solution. In this study, a novel measurement system based on the chemical imaging sensor was developed to observe the inside of a Y-shaped microfluidic channel while injecting two sample solutions from two branches. From the collected chemical images, it was clearly observed that the injected solutions formed laminar flows in the microfluidic channel. In addition, ion diffusion across the laminar flows was observed. This label-free method can acquire quantitative data of ion distribution and diffusion in microfluidic devices, which can be used to determine the diffusion coefficients, and therefore, the molecular weights of chemical species in the sample solution. Y1 - 2012 U6 - https://doi.org/10.1016/j.proeng.2012.09.289 SN - 1877-7058 N1 - Part of special issue "26th European Conference on Solid-State Transducers, EUROSENSOR 2012" IS - 47 SP - 886 EP - 889 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Wagner, Torsten A1 - Shigiahara, N. A1 - Miyamoto, K. A1 - Suzurikawa, J. A1 - Finger, F. A1 - Schöning, Michael Josef A1 - Yoshinobu, T. T1 - Light-addressable Potentiometric Sensors and Light–addressable Electrodes as a Combined Sensor-and-manipulator Microsystem with High Flexibility JF - Procedia Engineering N2 - This work describes the novel combination of the light-addressable electrode (LAE) and the light-addressable potentiometric sensor (LAPS) into a microsystem set-up. Both the LAE as well as the LAPS shares the principle of addressing the active spot by means of a light beam. This enables both systems to manipulate resp. to detect an analyte with a high spatial resolution. Hence, combining both principles into a single set-up enables the active stimulation e.g., by means of electrolysis and a simultaneous observation e.g., the response of an entrapped biological cell by detection of extracellular pH changes. The work will describe the principles of both technologies and the necessary steps to integrate them into a single set-up. Furthermore, examples of application and operation of such systems will be presented. Y1 - 2012 U6 - https://doi.org/10.1016/j.proeng.2012.09.290 SN - 1877-7058 N1 - Part of special issue "26th European Conference on Solid-State Transducers, EUROSENSOR 2012" IS - 47 SP - 890 EP - 893 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Pieper, Martin T1 - Vector hyperinterpolation on the sphere JF - Journal of approximation theory. 156 (2009), H. 2 Y1 - 2009 SN - 0021-9045 SP - 173 EP - 186 ER - TY - JOUR A1 - Murib, Mohammed S. A1 - Tran, Anh Quang A1 - Ceuninck, Ward de A1 - Schöning, Michael Josef A1 - Nesladek, Milos A1 - Serpengüzel, Ali A1 - Wagner, Patrick T1 - Analysis of an optical biosensor based on elastic light scattering from diamond-, glass-, and sapphire microspheres JF - Physica Status Solidi A N2 - Deoxyribonucleic acid (DNA) and protein recognition are now standard tools in biology. In addition, the special optical properties of microsphere resonators expressed by the high quality factor (Q-factor) of whispering gallery modes (WGMs) or morphology dependent resonances (MDRs) have attracted the attention of the biophotonic community. Microsphere-based biosensors are considered as powerful candidates to achieve label-free recognition of single molecules due to the high sensitivity of their WGMs. When the microsphere surface is modified with biomolecules, the effective refractive index and the effective size of the microsphere change resulting in a resonant wavelength shift. The transverse electric (TE) and the transverse magnetic (TM) elastic light scattering intensity of electromagnetic waves at 600 and 1400 nm are numerically calculated for DNA and unspecific binding of proteins to the microsphere surface. The effect of changing the optical properties was studied for diamond (refractive index 2.34), glass (refractive index 1.50), and sapphire (refractive index 1.75) microspheres with a 50 µm radius. The mode spacing, the linewidth of WGMs, and the shift of resonant wavelength due to the change in radius and refractive index, were analyzed by numerical simulations. Preliminary results of unspecific binding of biomolecules are presented. The calculated shift in WGMs can be used for biomolecules detection. Y1 - 2012 U6 - https://doi.org/10.1002/pssa.201100795 SN - 1862-6319 N1 - Special Issue: "Fundamentals and Applications of Diamond" VL - 209 IS - 9 SP - 1804 EP - 1810 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Logen, Steffen A1 - Höfken, Hans A1 - Schuba, Marko T1 - Simplifying RAM Forensics : A GUI and Extensions for the Volatility Framework T2 - 2012 Seventh International Conference on Availability, Reliability and Security (ARES), 20-24 August 2012, Prague, Czech Republic N2 - The Volatility Framework is a collection of tools for the analysis of computer RAM. The framework offers a multitude of analysis options and is used by many investigators worldwide. Volatility currently comes with a command line interface only, which might be a hinderer for some investigators to use the tool. In this paper we present a GUI and extensions for the Volatility Framework, which on the one hand simplify the usage of the tool and on the other hand offer additional functionality like storage of results in a database, shortcuts for long Volatility Framework command sequences, and entirely new commands based on correlation of data stored in the database. Y1 - 2012 SN - 978-1-4673-2244-7 U6 - https://doi.org/10.1109/ARES.2012.12 SP - 620 EP - 624 PB - IEEE CY - New York ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Using a cell-based gas biosensor for investigation of adverse effects of acetone vapors in vitro JF - Biosensors and Bioelectronics. 40 (2013), H. 1 Y1 - 2013 SN - 0956-5663 SP - 393 EP - 400 PB - Elsevier CY - Amsterdam ER - TY - THES A1 - Kotliar, Konstantin T1 - Functional in-vivo assessment and biofluidmechanical analysis of age-related and pathological microstructural changes in retinal vessels [Elektronische Ressource] Y1 - 2008 N1 - München, Techn. Univ., Diss., 2008 PB - - ER - TY - BOOK A1 - Grotendorst, Johannes T1 - Hierarchical methods for dynamics in complex molecular systems : IAS Winter School, 5 - 9 March 2012, Forschungszentrum Jülich GmbH ; lecture notes / ed. by Johannes Grotendorst, Godehard Sutmann, Gerhard Gompper, Dominik Marx Y1 - 2012 SN - 978-3-89336-768-9 N1 - (Schriften des Forschungszentrums Jülich IAS Series 10) PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Gutheil, Inge A1 - Berg, Tommy A1 - Grotendorst, Johannes T1 - Performance Analysis of Parallel Eigensolvers of two Libraries on BlueGene/P JF - Journal of Mathematics and Systems Science N2 - Many applications in computational science and engineering require the computation of eigenvalues and vectors of dense symmetric or Hermitian matrices. For example, in DFT (density functional theory) calculations on modern supercomputers 10% to 30% of the eigenvalues and eigenvectors of huge dense matrices have to be calculated. Therefore, performance and parallel scaling of the used eigensolvers is of upmost interest. In this article different routines of the linear algebra packages ScaLAPACK and Elemental for parallel solution of the symmetric eigenvalue problem are compared concerning their performance on the BlueGene/P supercomputer. Parameters for performance optimization are adjusted for the different data distribution methods used in the two libraries. It is found that for all test cases the new library Elemental which uses a two-dimensional element by element distribution of the matrices to the processors shows better performance than the old ScaLAPACK library which uses a block-cyclic distribution. KW - performance analysis KW - Elemental KW - ScaLAPACK KW - eigensolvers KW - Numerical linear algebra Y1 - 2012 U6 - https://doi.org/10.17265/2159-5291/2012.04.003 SN - 2159-5291 VL - 2 IS - 4 SP - 231 EP - 236 PB - David Publishing CY - Libertyville ER - TY - JOUR A1 - Grotendorst, Johannes T1 - IAS Winter School: Hierarchical Methods for Dynamics in Complex Molecular Systems JF - Innovatives Supercomputing in Deutschland : inSiDE. 10 (2012), H. 1 Y1 - 2012 SP - 104 PB - - ER - TY - CHAP A1 - Uibel, Thomas A1 - Blaß, Hans Joachim T1 - Edge Joints with Dowel Type Fasteners in Cross Laminated Timber T2 - Proceedings. CIB-W18 Meeting 2007, Bled, Slovenia 2007 Y1 - 2007 SN - 0945-6996 N1 - Paper 40-7-2 SP - 1 EP - 11 ER - TY - CHAP A1 - Uibel, Thomas A1 - Blaß, Hans Joachim ED - Cecotti, A. T1 - Determining Suitable Spacings and Distances for Self-tapping Screws by Experimental and Numerical Studies T2 - Proceedings of the 11th World Conference on Timber Engineering, WCTE 2010 : World Conference on Timber Engineering; [June 20 - 24, 2010, Riva del Garda, Trento, Italy] . Vol. III, Riva del Garda, Italy 2010 Y1 - 2010 N1 - Extended abstract. Full paper: DVD, Session 55, ID 108, 9 Seiten SP - 669 EP - 670 ER - TY - JOUR A1 - Hennemann, Jörg A1 - Kohl, Claus-Dieter A1 - Reisert, Steffen A1 - Kirchner, Patrick A1 - Schöning, Michael Josef T1 - Copper oxide nanofibres for detection of hydrogen peroxide vapour at high concentrations JF - physica status solidi (a) N2 - We present a sensor concept based on copper(II)oxide (CuO) nanofibres for the detection of hydrogen peroxide (H2O2) vapour in the percent per volume (% v/v) range. The fibres were produced by using the electrospinning technique. To avoid water condensation in the pores, the fibres were initially modified by an exposure to H2S to get an enclosed surface. By a thermal treatment at 350 °C the fibres were oxidised back to CuO. Thereby, the visible pores disappear which was verified by SEM analysis. The fibres show a decrease of resistance with increasing H2O2 concentration which is due to the fact that hydrogen peroxide is an oxidising gas and CuO a p-type semiconductor. The sensor shows a change of resistance within the minute range to the exposure until the maximum concentration of 6.9% v/v H2O2. At operating temperatures below 450 °C the corresponding sensor response to a concentration of 4.1% v/v increases. The sensor shows a good reproducibility of the signal at different measurements. CuO seems to be a suitable candidate for the detection of H2O2 vapour at high concentrations. Resistance behaviour of the sensor under exposure to H2O2 vapours between 2.3 and 6.9% v/v at an operating temperature of 450 °C. Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200775 SN - 1862-6319 VL - 210 IS - 5 SP - 859 EP - 863 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Reisert, Steffen A1 - Schneider, Benno A1 - Geissler, Hanno A1 - Gompel, Matthias van A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Multi-sensor chip for the investigation of different types of metal oxides for the detection of H2O2 in the ppm range JF - physica status solidi (a) N2 - In this work, a multi-sensor chip for the investigation of the sensing properties of different types of metal oxides towards hydrogen peroxide in the ppm range is presented. The fabrication process and physical characterization of the multi-sensor chip are described. Pure SnO2 and WO3 as well as Pd- and Pt-doped SnO2 films are characterized in terms of their sensitivity to H2O2. The sensing films have been prepared by drop-coating of water-dispensed nano-powders. A physical characterization, including scanning electron microscopy and X-ray diffraction analysis of the deposited metal-oxide films, was done. From the measurements in hydrogen peroxide atmosphere, it could be shown, that all of the tested metal oxide films are suitable for the detection of H2O2 in the ppm range. The highest sensitivity and reproducibility was achieved using Pt-doped SnO2. Calibration plot of a SnO2, WO3, Pt-, and Pd-doped SnO2 gas sensor for H2O2 concentrations in the ppm range. Y1 - 2013 SN - 1862-6319 VL - 210 IS - 5 SP - 898 EP - 904 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Hanssen, Henner A1 - Eberhardt, Karla A1 - Vilser, Walthard A1 - Schmaderer, Christoph A1 - Halle, Martin A1 - Heemann, Uwe A1 - Baumann, M. T1 - Retinal pulse wave velocity in young male normotensive and mildly hypertensive subjects JF - Microcirculation Y1 - 2013 SN - 1549-8719 N1 - Accepted Article (Accepted, unedited articles published online and citable. The final edited and typeset version of record will appear in future.) PB - Wiley CY - Malden ER - TY - JOUR A1 - Feucht, Nikolaus A1 - Schönbach, Etienne Michael A1 - Lanzl, Ines A1 - Kotliar, Konstantin A1 - Lohmann, Chris Patrick A1 - Maier, Mathias T1 - Changes in the foveal microstructure after intravitreal bevacizumab application in patients with retinal vascular disease JF - Clinical Ophthalmology Y1 - 2013 SN - 1177-5483 VL - 7 SP - 173 EP - 178 PB - Dove Medical Press CY - Auckland, New Zealand ER - TY - JOUR A1 - Heinzel, Alexander A1 - Schäfer, Ralf A1 - Müller, Hans-Wilhelm A1 - Schieffer, Andre A1 - Ingenhag, Ariane A1 - Eickhoff, Simon B. A1 - Northoff, Georg A1 - Franz, Matthias A1 - Hautzel, Hubertus T1 - Increased Activation of the Supragenual Anterior Cingulate Cortex during Visual Emotional Processing in Male Subjects with High Degrees of Alexithymia: An Event-Related fMRI Study JF - Psychotherapy and Psychosomatics N2 - Background: One of the most prominent neurobiological models of alexithymia assumes an altered function of the anterior cingulate cortex (ACC) as the crucial neural correlate of alexithymia. So far functional imaging studies have yielded inconclusive results. Therefore, we tested this hypothesis in healthy alexithymics and nonalexithymics in an event-related fMRI study. Methods: Thirty high- and 30 low-alexithymic right-handed male subjects (selected by the 20-item Toronto Alexithymia Scale, TAS-20) were investigated with event-related fMRI using a picture viewing paradigm. The stimuli consisted of happy, fearful and neutral facial expressions (Ekman-Friesen) as well as positive, negative and neutral pictures from the International Affective Picture System. Results: Contrasting the high-alexithymic with the low-alexithymic group we observed increased activation of the supragenual ACC for different emotional valences as well as for different emotional stimuli. Moreover, there was a positive correlation of the ACC with the individual TAS-20 scores but no correlations with the individual Beck Depression Inventory scores. Additionally, there was no difference in activity of the amygdala. Conclusions: We demonstrated that the supragenual ACC is constantly activated more strongly in alexithymic subjects and that this activation is related to the symptoms of alexithymia and not to associated symptoms such as depression. Therefore, our findings support the hypothesis of an altered function of the ACC in alexithymia. Y1 - 2010 U6 - https://doi.org/10.1159/000320121 SN - 0033-3190 VL - 79 IS - 6 SP - 363 EP - 370 PB - Karger CY - Basel ER - TY - JOUR A1 - Heinzel, Alexander A1 - Schäfer, Ralf A1 - Müller, Hans-Wilhelm A1 - Schieffer, Andre A1 - Ingenhag, Ariane A1 - Northoff, Georg A1 - Franz, Matthias A1 - Hautzel, Hubertus T1 - Differential modulation of valence and arousal in high-alexithymic and low-alexithymic individuals JF - Neuroreport N2 - High-alexithymic individuals are characterized by an impaired ability to identify and communicate emotions whereas low-alexithymic individuals have a wide-ranging ability to deal with emotions. This study examined the hypothesis that valence and arousal modifications of emotional stimuli differentially modulate cortical regions in high-alexithymic and low-alexithymic individuals. To this end, 28 high-alexithymic and 25 low-alexithymic individuals were investigated with event-related fMRI using visual emotional stimuli. We found differential neural activations in the dorsal anterior cingulate, the insula and the amygdala. We suggest that these differences may account for the impaired ability of high-alexithymic individuals to appropriately handle emotional stimuli. Y1 - 2010 U6 - https://doi.org/10.1097/WNR.0b013e32833f38e0 SN - 1473-558X VL - 21 IS - 15 SP - 998 EP - 1002 PB - Lippincott Williams & Wilkins CY - London ER - TY - JOUR A1 - Nomdedeu, Mar Monsonis A1 - Willen, Christine A1 - Schieffer, Andre A1 - Arndt, Hartmut T1 - Temperature-dependent ranges of coexistence in a model of a two-prey-one-predator microbial food web JF - Marine Biology N2 - The objective of our study was to analyze the effects of temperature on the population dynamics of a three-species food web consisting of two prey bacteria (Pedobacter sp. and Acinetobacter johnsonii) and a protozoan predator (Tetrahymena pyriformis) as model organisms. We assessed the effects of temperature on the growth rates of all three species with the objective of developing a model with four differential equations based on the experimental data. The following hypotheses were tested at a theoretical level: Firstly, temperature changes can affect the dynamic behavior of a system by temperature-dependent parameters and interactions and secondly, food web response to temperature cannot be derived from the single species temperature response. The main outcome of the study is that temperature changes affect the parameter range where coexistence is possible within all three species. This has significant consequences on our ideas regarding the evaluation of effects of global warming. Y1 - 2012 U6 - https://doi.org/10.1007/s00227-012-1966-x SN - 1432-1793 VL - 159 IS - 11 SP - 2423 EP - 2430 PB - Springer CY - Berlin ER - TY - THES A1 - Schieffer, Andre T1 - Studies on diversity and coexistence in an experimental microbial community N2 - Biodiversity and the coexistence of species have puzzled and fascinated biologists since decades and is a hotspot in todays’ natural sciences. Preserving this biodiversity is a great challenge as habitats and environments underlying tremendous changes like climate change and the loss of natural habitats, which are mainly due to anthropogenic influences. The coexistence of numerous species even in homogeneous environments is a stunning feature of natural communities and has been summarized under the term ‘paradox of plankton’. Up to now, there are several mechanisms discussed, which may contribute to local and global diversity of organisms. Several interspecific trade offs have been identified maintaining the coexistence of species like their abilities regarding competition and predator avoidance, their capability to disperse in space and time, and their ability to exploit variable resources. Further, micro-evolutionary dynamics supporting the coexistence of species have been added to our knowledge, and deriving from theoretical deterministic models, non-linear dynamics which describe the temporal fluctuation of abundances of organisms. Whereas competition and predation seem to be clue structural elements within interacting organisms, the intrinsic dynamic behavior – by means of temporal changes in abundance - plays an important role regarding coexistence within a community. The present work sheds light on different factors affecting the coexistence of species using experimental microbial model systems consisting of a bacterivorous ciliate as the predator and two bacteria strains as prey organism. Additionally, another experimental setup consisting of two up to five bacteria species competing for one limiting resource was investigated. Highly controllable chemostat systems were established to exclude extrinsic disturbances. According to theoretical analyses I was able to show - experimentally and theoretically - that phenotypic plasticity of one species within a microbial one-predator-two-prey food web enlarges the range of possible coexistence of all species under different dynamic conditions, compared to a food web without phenotypic plasticity. This was accompanied by non-linear (chaotic) population dynamics within all experimental systems showing phenotypic plasticity. The experiments on the interplay of competition, predation and invasion showed that all aspects have an influence on species coexistence. Under undisturbed controlled conditions all aspects were analyzed in detail and in combination. Populations showed oscillations which were shown by quasi-chaotic attractors in phase space diagrams. Competition experiments with two up to five bacteria species competing for one limiting resource showed that all organisms were able to coexist which was mediated by species oscillations entering a regime of chaos. Besides that fact it was found, that the productivity (biomass) as well as the total cell numbers – under the same nutrition supply – increased by an increasing number of species in the experimental systems. Up to now, the occurrence of non-linear dynamics in well controlled experimental studies has been recognized several times and this phenomenon seemed to be more common in natural systems than generally assumed. N2 - Biodiversität und die Koexistenz von Arten fasziniert und verblüfft Biologen seit Jahr-zehnten und stellen einen Schwerpunkt in der heutigen Umweltforschung dar. Der Schutz und die Konservierung dieser Mannigfaltigkeit stellen eine große Herausfor-derung dar, da die natürlichen Lebensräume sowie die Umwelt enormen Verände-rungen unterworfen sind, welche meist in einem anthropogenen Ursprung wurzeln. Die Koexistenz vieler Arten, auch in relativ homogenen Habitaten ist ein faszinieren-des Charakteristikum natürlicher Lebensgemeinschaften und wird als ‚Paradox des Planktons‘ bezeichnet. Gegenwärtig werden diverse Ursachen diskutiert, welche vermutlich zur lokalen und globalen Diversität von Organismen beitragen. Einige die-ser möglichen Ursachen, die zur Aufrechterhaltung der Koexistenz der Arten beitra-gen, wurden identifiziert: Das Vermögen der Konkurrenz- und Prädationsvermeidung, die Fähigkeit räumlicher sowie zeitlicher Verteilung, sowie das Vermögen variable Ressourcen zu nutzen. Des Weiteren wurden mikro-evolutionäre Phänomene und Dynamiken identifiziert, sowie, von theoretischen deterministischen Modellen ausge-hend, nichtlineare Dynamiken, welche die zeitlichen Schwankungen der Abundanzen von Organismen beschreiben. Diese Aspekte stellen die Schlüsselkomponenten zwi-schen interagierenden Organismen dar, wobei das intrinsiche, nicht lineare dynami-sche Verhalten in Form von zeitlichen Veränderungen in Abundanzen eine zusätzli-che entscheidende Rolle bezüglich der Koexistenz von Arten spielen kann. Einige dieser Aspekte wurden in der vorliegenden Arbeit untersucht. In Anlehnung an theoretische Analysen konnte experimentell sowie theoretisch gezeigt werden, dass phänotypische Plastizität in einer Bakterienart in einem mikrobiellen Ein-Räuber-zwei-Beute-Nahrungsgewebe den Bereich der möglichen Koexistenz unter sich än-dernden experimentellen Bedingungen (Änderungen der Durchflussraten der Chemostate) – im direkten Vergleich zu einem experimentellen Nahrungsgewebe ohne phänotypische Plastizität – erweitern kann. Dies wurde begleitet durch nicht lineare Abundanzschwankungen in den Populationen aller untersuchten Versuchs-ansätze. In weiteren Untersuchungen wurde das Zusammenspiel von Konkurrenz, Prädation und Invasion in einer experimentellen mikrobiellen Gemeinschaft untersucht. Unter kontrollierten Bedingungen konnten diese Aspekte detailliert untersucht werden und es konnten Aufschlüsse darüber gewonnen werden, welche Reaktionen (Interaktionen) innerhalb der untersuchten Gemeinschaften stattfinden. Im Versuchsverlauf wurden Veränderungen in den Abundanzen sowie chaotische Schwankungen der Zellzahlen festgestellt. In Konkurrenzexperimenten von zwei bis zu fünf um eine limitierende Ressource konkurrierende Bakterienarten konnte gezeigt werden, dass alle Arten – vermittelt durch chaotische Abundanzschwankungen – nebeneinander koexistieren konnten. Begleitend dazu wurde herausgefunden, dass die Produktivität (Biomasse) sowie die Gesamtzellzahl bei gleicher Nahrungsverfügbarkeit der experimentellen Systeme mit steigender Artenzahl zunehmen. Gegenwärtig ist das Auftreten von Chaos in gut kontrollierten experimentellen Studien vereinzelt beobachtet worden, wobei dieses Phänomen jedoch häufiger in der Natur aufzutreten scheint als generell vermutet. Y1 - 2012 N1 - Köln, Univ., Diss., 2012 ER - TY - CHAP A1 - Uibel, Thomas A1 - Blaß, Hans Joachim T1 - Load Carrying Capacity of Joints with Dowel Type Fasteners in Solid Wood Panels T2 - Proceedings. CIB-W18 Meeting 2006, Florence, Italy 2006 Y1 - 2006 SN - 0945-6996 N1 - Paper 39-7-5 SP - 1 EP - 10 ER - TY - JOUR A1 - Mosset, J.-B. A1 - Devroede, O. A1 - Krieguer, M. A1 - Rey, M. A1 - Vieira, J.-M. A1 - Jung, J. H. A1 - Kuntner, C. A1 - Streun, M. A1 - Ziemons, Karl A1 - Auffray, E. A1 - Sempere-Roldan, P. A1 - Lecoq, P. A1 - Bruyndonckx, P. A1 - Loude, J.-F. A1 - Tavernier, S. A1 - Morcel, C. T1 - Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator JF - IEEE Transactions on Nuclear Science N2 - This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 1 SP - 25 EP - 29 ER - TY - JOUR A1 - Streun, M. A1 - Beer, S. A1 - Hombach, T. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - PlanTIS: A positron emission tomograph for imaging 11C transport in plants JF - 2007 IEEE Nuclear Science Symposium Conference Record, Vol. 6 N2 - Plant growth and transport processes are highly dynamic. They are characterized by plant-internal control processes and by strong interactions with the spatially and temporally varying environment. Analysis of structure- function relations of growth and transport in plants will strongly benefit from the development of non-invasive techniques. PlanTIS (Plant Tomographic Imaging System) is designed for non-destructive 3D-imaging of positron emitting radiotracers. It will permit functional analysis of the dynamics of carbon distribution in plants including bulky organs. It will be applicable for screening transport properties of plants to evaluate e.g. temperature adaptation of genetically modified plants. PlanTIS is a PET scanner dedicated to monitor the dynamics of the 11C distribution within a plant while or after assimilation of 11CO2. Front end electronics and data acquisition architecture of the scanner are based on the ClearPETTM system [1]. Four detector modules form one of two opposing detector blocks. Optionally, a hardware coincidence detection between the blocks can be applied. In general the scan duration is rather long (~ 1 hour) compared to the decay time of 11C (20 min). As a result the count rates can vary over a wide range and accurate dead time correction is necessary. Y1 - 2008 SN - 1082-3654 SP - 4110 EP - 4112 ER - TY - JOUR A1 - Ziemons, Karl A1 - Bruyndonckx, P. A1 - Perez, J. M. A1 - Pietrzyk, U. A1 - Rato, P. A1 - Tavernier, S. T1 - Beyond ClearPET: Next Aims JF - 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro Symposium Proceedings ISBI 2008 N2 - The CRYSTAL CLEAR collaboration, in short CCC, is a consortium of 12 academic institutions, mainly from Europe, joining efforts in the area of developing instrumentation for nuclear medicine and medical imaging. In the framework of the CCC a high performance small animal PET system, called ClearPET, was developed by using new technologies in electronics and crystals in a phoswich arrangement combining two types of lutetium- based scintillator materials: LSO:Ce and LuYAP:Ce. Our next aim will be the development of hybrid image systems. Hybrid MR-PET imaging has many unique advantages for brain research. This has sparked a new research line within CCC for the development of novel MR-PET compatible technologies. MRI is not as sensitive as PET but PET has poorer spatial resolution than MRI. Two major advantages of PET are sensitivity and its ability to acquire metabolic information. To assess these innovations, the development of a 9.4T hybrid animal MR-PET scanner is proposed based on an existing 9.4T MR scanner that will be adapted to enable simultaneous acquisition of MR and PET data using cutting- edge technology for both MR and PET. Y1 - 2008 SN - 978-1-4244-2003-2 SP - 1421 EP - 1424 ER - TY - JOUR A1 - Jahnke, Siegfried A1 - Menzel, Marion I. A1 - Dusschoten, Dagmar van A1 - Roeb, Gerhard W. A1 - Bühler, Jonas A1 - Minwuyelet, Senay A1 - Blümler, Peter A1 - Temperton, Vicky M. A1 - Hombach, Thomas A1 - Streun, Matthias A1 - Beer, Simone A1 - Khodaverdi, Maryam A1 - Ziemons, Karl A1 - Coenen, Heinz H. A1 - Schurr, Ulrich T1 - Combined MRI–PET dissects dynamic changes in plant structures and functions JF - The Plant Journal N2 - Unravelling the factors determining the allocation of carbon to various plant organs is one of the great challenges of modern plant biology. Studying allocation under close to natural conditions requires non-invasive methods, which are now becoming available for measuring plants on a par with those developed for humans. By combining magnetic resonance imaging (MRI) and positron emission tomography (PET), we investigated three contrasting root/shoot systems growing in sand or soil, with respect to their structures, transport routes and the translocation dynamics of recently fixed photoassimilates labelled with the short-lived radioactive carbon isotope 11C. Storage organs of sugar beet (Beta vulgaris) and radish plants (Raphanus sativus) were assessed using MRI, providing images of the internal structures of the organs with high spatial resolution, and while species-specific transport sectoralities, properties of assimilate allocation and unloading characteristics were measured using PET. Growth and carbon allocation within complex root systems were monitored in maize plants (Zea mays), and the results may be used to identify factors affecting root growth in natural substrates or in competition with roots of other plants. MRI–PET co-registration opens the door for non-invasive analysis of plant structures and transport processes that may change in response to genomic, developmental or environmental challenges. It is our aim to make the methods applicable for quantitative analyses of plant traits in phenotyping as well as in understanding the dynamics of key processes that are essential to plant performance. Y1 - 2009 SN - 1365-313X VL - 59 IS - 4 SP - 634 EP - 644 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Wedrowski, M. A1 - Bruyndonckx, P. A1 - Tavernier, S. A1 - Zhi, L. A1 - Dang, J. A1 - Mendes, P. R. A1 - Perez, J. M. A1 - Ziemons, Karl T1 - Robustness of neural networks algorithm for gamma detection in monolithic block detector, positron emission tomography JF - 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The monolithic scintillator block approach for gamma detection in the Positron Emission Tomography (PET) avoids estimating Depth of Interaction (DOI), reduces dead zones in detector and diminishes costs of detector production. Neural Networks (NN) are very efficient to determine the entrance point of a gamma incident on a scintillator block. This paper presents results on the robustness of the spatial resolution as a function of the random fraction in the data, temperature and HV fluctuations. This is important when implementing the method in a real scanner. Measurements were done with two Hamamatsu S8550 APD arrays, glued on a 20 × 20 × 10 mm3 monolithic LSO crystal block. Y1 - 2009 SN - 1082-3654 SP - 2625 EP - 2628 ER - TY - JOUR A1 - Streun, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - A compact PET detector readout using charge-to-time conversion JF - 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics. Y1 - 2009 SN - 1082-3654 SP - 1868 EP - 1870 PB - IEEE CY - New York ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse recording by free-running sampling JF - IEEE Transactions on Nuclear Science N2 - Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free-running ADCs at a sampling rate of 40 MHz. A four-channel acquisition board has been developed which is equipped with four 12-bit ADCs connected to one field programmable gate array (FPGA). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware trigger can be omitted. The method of free-running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. This information is crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows very high count rates to be dealt with. Since this method is to be employed in positron emission tomography (PET), the position of an event is also important. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO scintillators coupled to the PS-PMT are presented here Y1 - 2001 SN - 0018-9499 VL - 48 IS - 3 SP - 524 EP - 526 ER - TY - JOUR A1 - Heinrich, U. A1 - Blum, A. A1 - Bussmann, N. A1 - Engels, R. A1 - Kemmerling, G. A1 - Weber, S. A1 - Ziemons, Karl T1 - Statistical studies on the light output and energy resolution of small LSO single crystals with different surface treatments combined with various reflector materials JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The optimization of light output and energy resolution of scintillators is of special interest for the development of high resolution and high sensitivity PET. The aim of this work is to obtain statistically reliable results concerning optimal surface treatment of scintillation crystals and the selection of reflector material. For this purpose, raw, mechanically polished and etched LSO crystals (size 2×2×10 mm3) were combined with various reflector materials (Teflon tape, Teflon matrix, BaSO4) and exposed to a 22Na source. In order to ensure the statistical reliability of the results, groups of 10 LSO crystals each were measured for all combinations of surface treatment and reflector material. Using no reflector material the light output increased up to 551±35% by mechanical polishing the surface compared to 100±5% for raw crystals. Etching the surface increased the light output to 441±29%. The untreated crystals had an energy resolution of 24.6±4.0%. By mechanical polishing the surface it was possible to achieve an energy resolution of 13.2±0.8%, by etching of 14.8±0.7%. In combination with BaSO4 as reflector material the maximum increase of light output has been established to 932±57% for mechanically polished and 895±61% for etched crystals. The combination with BaSO4 also caused the best improvement of the energy resolution up to 11.6±0.2% for mechanically polished and 12.2±0.3% for etched crystals. Relating to the light output there was no significant statistical difference between the two surface treatments in combination with BaSO4. In contrast to this, the statistical results of the energy resolution have shown the combination of mechanical polishing and BaSO4 as the optimum. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 60 EP - 66 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system with free running ADCs JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - A small PET system has been built up with two multichannel photomultipliers, which are attached to a matrix of 64 single LSO crystals each. The signal from each multiplier is being sampled continuously by a 12 bit ADC at a sampling frequency of 40 MHz. In case of a scintillation pulse a subsequent FPGA sends the corresponding set of samples together with the channel information and a time mark to the host computer. The data transfer is performed with a rate of 20 MB/s. On the host all necessary information is extracted from the data. The pulse energy is determined, coincident events are detected and multiple hits within one matrix can be identified. In order to achieve a narrow time window the pulse starting time is refined further than the resolution of the time mark (=25 ns) would allow. This is possible by interpolating between the pulse samples. First data obtained from this system will be presented. The system is part of developments for a much larger system and has been created to study the feasibility and performance of the technique and the hardware architecture. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 18 EP - 21 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Coincidence detection by digital processing of free-running sampled pulses JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns. Y1 - 2002 SN - 0168-9002 VL - 487 IS - 3 SP - 530 EP - 534 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Pauly, F. A1 - Schroder, G. A1 - Ziemons, Karl A1 - Sievering, R. A1 - Halling, H. T1 - Preliminary studies of a micro-CT for a combined small animal PET/CT scanner JF - 2001 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - We are developing an X-ray computed tomography (CT) system which will be combined with a high resolution animal PET system. This permits acquisition of both molecular and anatomical images in a single machine. In particular the CT will also be utilized for the quantification of the animal PET data by providing accurate data for attenuation correction. A first prototype has been built using a commercially available plane silicon diode detector. A cone-beam reconstruction provides the images using the Feldkamp algorithm. First measurements with this system have been performed on a mouse. It could be shown that the CT setup fulfils all demands for a high quality image of the skeleton of the mouse. It is also suited for soft tissue measurements. To improve contrast and resolution and to acquire the X-ray energy further development of the system, especially the use of semiconductor detectors and iterative reconstruction algorithms are planned. Y1 - 2002 SN - 1082-3654 SP - 1605 EP - 1606 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system based on data processing of free-running sampled pulses JF - 2001 IEEE Nuclear Science Symposium Conference Record, Vol. 2 N2 - Within the developments for the Crystal Clear small animal PET project (CLEARPET) a dual head PET system has been established. The basic principle is the early digitization of the detector pulses by free running ADCs. The determination of the γ-energy and also the coincidence detection is performed by data processing of the sampled pulses on the host computer. Therefore a time mark is attached to each pulse identifying the current cycle of the 40 MHz sampling clock. In order to refine the time resolution the pulse starting time is interpolated from the samples of the pulse rise. The detector heads consist of multichannel PMTs with a single LSO scintillator crystal coupled to each channel. For each PMT only one ADC is required. The position of an event is obtained separately from trigger signals generated for each single channel. An FPGA is utilized for pulse buffering, generation of the time mark and for the data transfer to the host via a fast I/O-interface. Y1 - 2002 SN - 1082-3654 SP - 693 EP - 694 ER - TY - JOUR A1 - Heinrichs, U. A1 - Pietrzyk, U. A1 - Ziemons, Karl T1 - Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 JF - 2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - Within the Crystal Clear Collaboration four centres are developing 2nd generation high performance small animal PET scanners for different kinds of animals and medical applications. The first prototypes are PMT-based systems including depth of interaction (DOI) detection by using a phoswich layer of LSO and LuYAP. The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in FOVs caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN) was used. The simulations have shown that all PMT designs with one-to-one coupling of crystals have a very nonlinear axial sensitivity profile. By shifting every other PMT 1/4 of a PMT length in axial direction the sampling of the FOVs became more homogeneous. At an energy threshold of 350keV the regression coefficient increases from 0.818 for the non-shifted to 0.993 for the shifted design. Simulations of a point source centred in the FOV (threshold: 350keV) resulted in sensitivities of 4.2% for a 4×20PMT (LSO/LuYAP a 10mm) and 3.8% for a 4×16PMT (LSO/LuYAP a 8mm) ring design. The 3D-MLEM reconstruction of a point source shows the enormous improvement of resolution using a crystal double layer with DOI (3.1mm at 40mm from CFOV) instead of a 20mm single layer (11.9mm). Y1 - 2003 SN - 1082-3654 SP - 682 EP - 686 ER - TY - JOUR A1 - Heinrichs, U. A1 - Pietrzyk, U. A1 - Ziemons, Karl T1 - Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 JF - IEEE Transactions on Nuclear Science N2 - Within the Crystal Clear Collaboration (CCC), four centers are developing second generation high performance small animal positron emission tomography (PET) scanners for different kinds of animals and medical applications. The first prototypes are photomultiplier tube (PMT)-based systems including depth of interaction (DOI) detection by using a phoswich layer of lutetium oxyorthosilicate (LSO) and lutetium yttrium aluminum perovskite (LuYAP). The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in fields of view (FOVs) caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN, Geneva, Switzerland) was used. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 5 SP - 1428 EP - 1432 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - 2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 1082-3654 SP - 1636 EP - 1639 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - IEEE Transactions on Nuclear Science N2 - A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 3 SP - 344 EP - 347 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chaziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different microCT scanner configurations by GEANT4 simulations JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - This study has been performed to design the combination of the new ClearPET TM (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal Positron Emission Tomography (PET) system, with a microComputed Tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2004 SN - 1082-3654 SP - 2989 EP - 2993 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. T1 - The ClearPET TM LSO/LuYAP phoswich scanner: a high performance small animal PET system JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes. Y1 - 2004 SN - 1082-3654 SP - 1728 EP - 1732 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Brökel, M. A1 - Fuss, L. A1 - Larue, H. A1 - Parl, C. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - The ClearPET data acquisition JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - Within the Crystal Clear Collaboration a modular system for a small animal PET scanner (ClearPET™) has been developed. The modularity allows the assembly of scanners of different sizes and characteristics in order to fit the specific needs of the individual member institutions. Now a first demonstrator is being completed in Julich. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to multi-channel photomultipliers (PMTs). A free-running ADC digitizes the signal from the PMT and the complete scintillation pulses are sampled by an FPGA and sent with 20 MB/S to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. An advantage of that is that the coincidence window and the dimensions of the field of view can be adjusted easily. The ClearPET™ demonstrator is equipped with 10240 crystals on 80 PMTs. This paper presents an overview of the data acquisition system. Y1 - 2004 SN - 1082-3654 SP - 3097 EP - 3100 ER - TY - JOUR A1 - Christ, D. A1 - Hollendung, A. A1 - Larue, H. A1 - Parl, C. A1 - Streun, M. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. T1 - Homogenization of the MultiChannel PM gain by inserting light attenuating masks JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - MultiChannel Photomultipliers (PM), like the R7600-00-M64 or R5900-00-M64 from Hamamatsu, are often chosen as photodetectors in high-resolution positron emission tomography (PET). A major problem of this PM is the nonuniform channel gain. In order to solve this problem, light attenuating masks were created. The aim of the masks is a homogenization of the output of all 64 channels using different hole sizes at the channel positions. The hole area, which is individually defined for the different channels, is inversely proportional to the channel gain. The measurements by inserting light attenuating masks improved a homogenization to a ratio of 1:1.2. Y1 - 2004 SN - 1082-3654 SP - 2382 EP - 2385 ER - TY - JOUR A1 - Ziemons, Karl A1 - Heinrichs, U. A1 - Streun, M. A1 - Pietrzyk, U. T1 - Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. Y1 - 2004 SN - 1082-3654 SP - 3053 EP - 3056 ER - TY - JOUR A1 - Auffray, E. A1 - Bruyndonckx, P. A1 - Devroede, O. A1 - Fedorov, A. A1 - Ziemons, Karl T1 - The ClearPET project JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view. Y1 - 2004 SN - 0168-9002 N1 - Proceedings of the 2nd International Conference on Imaging Technologies in Biomedical Sciences VL - 527 IS - 1-2 SP - 171 EP - 174 ER - TY - JOUR A1 - Streun, M. A1 - Christ, D. A1 - Hellendung, A. A1 - Larue, H. A1 - Ziemons, Karl A1 - Halling, H. T1 - Effects of crosstalk and gain nonuniformity using multichannel PMTs in the Clearpet® scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 402 EP - 405 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. A1 - Bruyndonckx, P. T1 - The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view. Preliminary data shows a correct identification of the crystal layer about (98±1)%. Typically the energy resolution is (23.3±0.5)% for the luyap layer and (15.4±0.4)% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 307 EP - 311 ER - TY - JOUR A1 - Beer, S. A1 - Streun, M. A1 - Hombach, T. A1 - Buehler, J. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants JF - Physics in Medicine and Biology N2 - Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements. Y1 - 2010 U6 - https://doi.org/10.1088/0031-9155/55/3/006 SN - 1361-6560 VL - 55 IS - 3 SP - 635 EP - 646 PB - IOP CY - Bristol ER - TY - JOUR A1 - Herzog, Hans A1 - Pietrzyk, Uwe A1 - Shah, N. Jon A1 - Ziemons, Karl T1 - The current state, challenges and perspectives of MR-PET JF - Neuroimage N2 - Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization. Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop. Y1 - 2010 U6 - https://doi.org/10.1016/j.neuroimage.2009.10.036 SN - 1053-8119 VL - 49 IS - 3 SP - 2072 EP - 2082 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Parl, C. A1 - Larue, H. A1 - Streun, M. A1 - Ziemons, Karl T1 - Double-side-readout technique for SiPM-matrices JF - 2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit. Y1 - 2011 SN - 1095-7863 SP - 1486 EP - 1487 PB - IEEE CY - New York ER -