TY - JOUR A1 - Nomdedeu, Mar Monsonis A1 - Willen, Christine A1 - Schieffer, Andre A1 - Arndt, Hartmut T1 - Temperature-dependent ranges of coexistence in a model of a two-prey-one-predator microbial food web JF - Marine Biology N2 - The objective of our study was to analyze the effects of temperature on the population dynamics of a three-species food web consisting of two prey bacteria (Pedobacter sp. and Acinetobacter johnsonii) and a protozoan predator (Tetrahymena pyriformis) as model organisms. We assessed the effects of temperature on the growth rates of all three species with the objective of developing a model with four differential equations based on the experimental data. The following hypotheses were tested at a theoretical level: Firstly, temperature changes can affect the dynamic behavior of a system by temperature-dependent parameters and interactions and secondly, food web response to temperature cannot be derived from the single species temperature response. The main outcome of the study is that temperature changes affect the parameter range where coexistence is possible within all three species. This has significant consequences on our ideas regarding the evaluation of effects of global warming. Y1 - 2012 U6 - https://doi.org/10.1007/s00227-012-1966-x SN - 1432-1793 VL - 159 IS - 11 SP - 2423 EP - 2430 PB - Springer CY - Berlin ER - TY - THES A1 - Schieffer, Andre T1 - Studies on diversity and coexistence in an experimental microbial community N2 - Biodiversity and the coexistence of species have puzzled and fascinated biologists since decades and is a hotspot in todays’ natural sciences. Preserving this biodiversity is a great challenge as habitats and environments underlying tremendous changes like climate change and the loss of natural habitats, which are mainly due to anthropogenic influences. The coexistence of numerous species even in homogeneous environments is a stunning feature of natural communities and has been summarized under the term ‘paradox of plankton’. Up to now, there are several mechanisms discussed, which may contribute to local and global diversity of organisms. Several interspecific trade offs have been identified maintaining the coexistence of species like their abilities regarding competition and predator avoidance, their capability to disperse in space and time, and their ability to exploit variable resources. Further, micro-evolutionary dynamics supporting the coexistence of species have been added to our knowledge, and deriving from theoretical deterministic models, non-linear dynamics which describe the temporal fluctuation of abundances of organisms. Whereas competition and predation seem to be clue structural elements within interacting organisms, the intrinsic dynamic behavior – by means of temporal changes in abundance - plays an important role regarding coexistence within a community. The present work sheds light on different factors affecting the coexistence of species using experimental microbial model systems consisting of a bacterivorous ciliate as the predator and two bacteria strains as prey organism. Additionally, another experimental setup consisting of two up to five bacteria species competing for one limiting resource was investigated. Highly controllable chemostat systems were established to exclude extrinsic disturbances. According to theoretical analyses I was able to show - experimentally and theoretically - that phenotypic plasticity of one species within a microbial one-predator-two-prey food web enlarges the range of possible coexistence of all species under different dynamic conditions, compared to a food web without phenotypic plasticity. This was accompanied by non-linear (chaotic) population dynamics within all experimental systems showing phenotypic plasticity. The experiments on the interplay of competition, predation and invasion showed that all aspects have an influence on species coexistence. Under undisturbed controlled conditions all aspects were analyzed in detail and in combination. Populations showed oscillations which were shown by quasi-chaotic attractors in phase space diagrams. Competition experiments with two up to five bacteria species competing for one limiting resource showed that all organisms were able to coexist which was mediated by species oscillations entering a regime of chaos. Besides that fact it was found, that the productivity (biomass) as well as the total cell numbers – under the same nutrition supply – increased by an increasing number of species in the experimental systems. Up to now, the occurrence of non-linear dynamics in well controlled experimental studies has been recognized several times and this phenomenon seemed to be more common in natural systems than generally assumed. N2 - Biodiversität und die Koexistenz von Arten fasziniert und verblüfft Biologen seit Jahr-zehnten und stellen einen Schwerpunkt in der heutigen Umweltforschung dar. Der Schutz und die Konservierung dieser Mannigfaltigkeit stellen eine große Herausfor-derung dar, da die natürlichen Lebensräume sowie die Umwelt enormen Verände-rungen unterworfen sind, welche meist in einem anthropogenen Ursprung wurzeln. Die Koexistenz vieler Arten, auch in relativ homogenen Habitaten ist ein faszinieren-des Charakteristikum natürlicher Lebensgemeinschaften und wird als ‚Paradox des Planktons‘ bezeichnet. Gegenwärtig werden diverse Ursachen diskutiert, welche vermutlich zur lokalen und globalen Diversität von Organismen beitragen. Einige die-ser möglichen Ursachen, die zur Aufrechterhaltung der Koexistenz der Arten beitra-gen, wurden identifiziert: Das Vermögen der Konkurrenz- und Prädationsvermeidung, die Fähigkeit räumlicher sowie zeitlicher Verteilung, sowie das Vermögen variable Ressourcen zu nutzen. Des Weiteren wurden mikro-evolutionäre Phänomene und Dynamiken identifiziert, sowie, von theoretischen deterministischen Modellen ausge-hend, nichtlineare Dynamiken, welche die zeitlichen Schwankungen der Abundanzen von Organismen beschreiben. Diese Aspekte stellen die Schlüsselkomponenten zwi-schen interagierenden Organismen dar, wobei das intrinsiche, nicht lineare dynami-sche Verhalten in Form von zeitlichen Veränderungen in Abundanzen eine zusätzli-che entscheidende Rolle bezüglich der Koexistenz von Arten spielen kann. Einige dieser Aspekte wurden in der vorliegenden Arbeit untersucht. In Anlehnung an theoretische Analysen konnte experimentell sowie theoretisch gezeigt werden, dass phänotypische Plastizität in einer Bakterienart in einem mikrobiellen Ein-Räuber-zwei-Beute-Nahrungsgewebe den Bereich der möglichen Koexistenz unter sich än-dernden experimentellen Bedingungen (Änderungen der Durchflussraten der Chemostate) – im direkten Vergleich zu einem experimentellen Nahrungsgewebe ohne phänotypische Plastizität – erweitern kann. Dies wurde begleitet durch nicht lineare Abundanzschwankungen in den Populationen aller untersuchten Versuchs-ansätze. In weiteren Untersuchungen wurde das Zusammenspiel von Konkurrenz, Prädation und Invasion in einer experimentellen mikrobiellen Gemeinschaft untersucht. Unter kontrollierten Bedingungen konnten diese Aspekte detailliert untersucht werden und es konnten Aufschlüsse darüber gewonnen werden, welche Reaktionen (Interaktionen) innerhalb der untersuchten Gemeinschaften stattfinden. Im Versuchsverlauf wurden Veränderungen in den Abundanzen sowie chaotische Schwankungen der Zellzahlen festgestellt. In Konkurrenzexperimenten von zwei bis zu fünf um eine limitierende Ressource konkurrierende Bakterienarten konnte gezeigt werden, dass alle Arten – vermittelt durch chaotische Abundanzschwankungen – nebeneinander koexistieren konnten. Begleitend dazu wurde herausgefunden, dass die Produktivität (Biomasse) sowie die Gesamtzellzahl bei gleicher Nahrungsverfügbarkeit der experimentellen Systeme mit steigender Artenzahl zunehmen. Gegenwärtig ist das Auftreten von Chaos in gut kontrollierten experimentellen Studien vereinzelt beobachtet worden, wobei dieses Phänomen jedoch häufiger in der Natur aufzutreten scheint als generell vermutet. Y1 - 2012 N1 - Köln, Univ., Diss., 2012 ER - TY - CHAP A1 - Uibel, Thomas A1 - Blaß, Hans Joachim T1 - Load Carrying Capacity of Joints with Dowel Type Fasteners in Solid Wood Panels T2 - Proceedings. CIB-W18 Meeting 2006, Florence, Italy 2006 Y1 - 2006 SN - 0945-6996 N1 - Paper 39-7-5 SP - 1 EP - 10 ER - TY - JOUR A1 - Mosset, J.-B. A1 - Devroede, O. A1 - Krieguer, M. A1 - Rey, M. A1 - Vieira, J.-M. A1 - Jung, J. H. A1 - Kuntner, C. A1 - Streun, M. A1 - Ziemons, Karl A1 - Auffray, E. A1 - Sempere-Roldan, P. A1 - Lecoq, P. A1 - Bruyndonckx, P. A1 - Loude, J.-F. A1 - Tavernier, S. A1 - Morcel, C. T1 - Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator JF - IEEE Transactions on Nuclear Science N2 - This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 1 SP - 25 EP - 29 ER - TY - JOUR A1 - Streun, M. A1 - Beer, S. A1 - Hombach, T. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - PlanTIS: A positron emission tomograph for imaging 11C transport in plants JF - 2007 IEEE Nuclear Science Symposium Conference Record, Vol. 6 N2 - Plant growth and transport processes are highly dynamic. They are characterized by plant-internal control processes and by strong interactions with the spatially and temporally varying environment. Analysis of structure- function relations of growth and transport in plants will strongly benefit from the development of non-invasive techniques. PlanTIS (Plant Tomographic Imaging System) is designed for non-destructive 3D-imaging of positron emitting radiotracers. It will permit functional analysis of the dynamics of carbon distribution in plants including bulky organs. It will be applicable for screening transport properties of plants to evaluate e.g. temperature adaptation of genetically modified plants. PlanTIS is a PET scanner dedicated to monitor the dynamics of the 11C distribution within a plant while or after assimilation of 11CO2. Front end electronics and data acquisition architecture of the scanner are based on the ClearPETTM system [1]. Four detector modules form one of two opposing detector blocks. Optionally, a hardware coincidence detection between the blocks can be applied. In general the scan duration is rather long (~ 1 hour) compared to the decay time of 11C (20 min). As a result the count rates can vary over a wide range and accurate dead time correction is necessary. Y1 - 2008 SN - 1082-3654 SP - 4110 EP - 4112 ER - TY - JOUR A1 - Ziemons, Karl A1 - Bruyndonckx, P. A1 - Perez, J. M. A1 - Pietrzyk, U. A1 - Rato, P. A1 - Tavernier, S. T1 - Beyond ClearPET: Next Aims JF - 5th IEEE International Symposium on Biomedical Imaging: From Nano to Macro Symposium Proceedings ISBI 2008 N2 - The CRYSTAL CLEAR collaboration, in short CCC, is a consortium of 12 academic institutions, mainly from Europe, joining efforts in the area of developing instrumentation for nuclear medicine and medical imaging. In the framework of the CCC a high performance small animal PET system, called ClearPET, was developed by using new technologies in electronics and crystals in a phoswich arrangement combining two types of lutetium- based scintillator materials: LSO:Ce and LuYAP:Ce. Our next aim will be the development of hybrid image systems. Hybrid MR-PET imaging has many unique advantages for brain research. This has sparked a new research line within CCC for the development of novel MR-PET compatible technologies. MRI is not as sensitive as PET but PET has poorer spatial resolution than MRI. Two major advantages of PET are sensitivity and its ability to acquire metabolic information. To assess these innovations, the development of a 9.4T hybrid animal MR-PET scanner is proposed based on an existing 9.4T MR scanner that will be adapted to enable simultaneous acquisition of MR and PET data using cutting- edge technology for both MR and PET. Y1 - 2008 SN - 978-1-4244-2003-2 SP - 1421 EP - 1424 ER - TY - JOUR A1 - Jahnke, Siegfried A1 - Menzel, Marion I. A1 - Dusschoten, Dagmar van A1 - Roeb, Gerhard W. A1 - Bühler, Jonas A1 - Minwuyelet, Senay A1 - Blümler, Peter A1 - Temperton, Vicky M. A1 - Hombach, Thomas A1 - Streun, Matthias A1 - Beer, Simone A1 - Khodaverdi, Maryam A1 - Ziemons, Karl A1 - Coenen, Heinz H. A1 - Schurr, Ulrich T1 - Combined MRI–PET dissects dynamic changes in plant structures and functions JF - The Plant Journal N2 - Unravelling the factors determining the allocation of carbon to various plant organs is one of the great challenges of modern plant biology. Studying allocation under close to natural conditions requires non-invasive methods, which are now becoming available for measuring plants on a par with those developed for humans. By combining magnetic resonance imaging (MRI) and positron emission tomography (PET), we investigated three contrasting root/shoot systems growing in sand or soil, with respect to their structures, transport routes and the translocation dynamics of recently fixed photoassimilates labelled with the short-lived radioactive carbon isotope 11C. Storage organs of sugar beet (Beta vulgaris) and radish plants (Raphanus sativus) were assessed using MRI, providing images of the internal structures of the organs with high spatial resolution, and while species-specific transport sectoralities, properties of assimilate allocation and unloading characteristics were measured using PET. Growth and carbon allocation within complex root systems were monitored in maize plants (Zea mays), and the results may be used to identify factors affecting root growth in natural substrates or in competition with roots of other plants. MRI–PET co-registration opens the door for non-invasive analysis of plant structures and transport processes that may change in response to genomic, developmental or environmental challenges. It is our aim to make the methods applicable for quantitative analyses of plant traits in phenotyping as well as in understanding the dynamics of key processes that are essential to plant performance. Y1 - 2009 SN - 1365-313X VL - 59 IS - 4 SP - 634 EP - 644 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Wedrowski, M. A1 - Bruyndonckx, P. A1 - Tavernier, S. A1 - Zhi, L. A1 - Dang, J. A1 - Mendes, P. R. A1 - Perez, J. M. A1 - Ziemons, Karl T1 - Robustness of neural networks algorithm for gamma detection in monolithic block detector, positron emission tomography JF - 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The monolithic scintillator block approach for gamma detection in the Positron Emission Tomography (PET) avoids estimating Depth of Interaction (DOI), reduces dead zones in detector and diminishes costs of detector production. Neural Networks (NN) are very efficient to determine the entrance point of a gamma incident on a scintillator block. This paper presents results on the robustness of the spatial resolution as a function of the random fraction in the data, temperature and HV fluctuations. This is important when implementing the method in a real scanner. Measurements were done with two Hamamatsu S8550 APD arrays, glued on a 20 × 20 × 10 mm3 monolithic LSO crystal block. Y1 - 2009 SN - 1082-3654 SP - 2625 EP - 2628 ER - TY - JOUR A1 - Streun, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - A compact PET detector readout using charge-to-time conversion JF - 2009 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The readout of gamma detectors is considerably simplified when the event intensity is encoded as a pulse width (Pulse Width Modulation, PWM). Time-to-Digital-Converters (TDC) replace the conventional ADCs and multiple TDCs can be realized easily in one PLD chip (Programmable Logic Device). The output of a PWM stage is only one digital signal per channel which is well suited for transport so that further processing can be performed apart from the detector. This is particularly interesting for large systems with high channel density (e.g. high resolution scanners). In this work we present a circuit with a linear transfer function that requires a minimum of components by performing the PWM already in the preamp stage. This allows a very compact and also cost-efficient implementation of the front-end electronics. Y1 - 2009 SN - 1082-3654 SP - 1868 EP - 1870 PB - IEEE CY - New York ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse recording by free-running sampling JF - IEEE Transactions on Nuclear Science N2 - Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free-running ADCs at a sampling rate of 40 MHz. A four-channel acquisition board has been developed which is equipped with four 12-bit ADCs connected to one field programmable gate array (FPGA). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware trigger can be omitted. The method of free-running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. This information is crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows very high count rates to be dealt with. Since this method is to be employed in positron emission tomography (PET), the position of an event is also important. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO scintillators coupled to the PS-PMT are presented here Y1 - 2001 SN - 0018-9499 VL - 48 IS - 3 SP - 524 EP - 526 ER - TY - JOUR A1 - Heinrich, U. A1 - Blum, A. A1 - Bussmann, N. A1 - Engels, R. A1 - Kemmerling, G. A1 - Weber, S. A1 - Ziemons, Karl T1 - Statistical studies on the light output and energy resolution of small LSO single crystals with different surface treatments combined with various reflector materials JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The optimization of light output and energy resolution of scintillators is of special interest for the development of high resolution and high sensitivity PET. The aim of this work is to obtain statistically reliable results concerning optimal surface treatment of scintillation crystals and the selection of reflector material. For this purpose, raw, mechanically polished and etched LSO crystals (size 2×2×10 mm3) were combined with various reflector materials (Teflon tape, Teflon matrix, BaSO4) and exposed to a 22Na source. In order to ensure the statistical reliability of the results, groups of 10 LSO crystals each were measured for all combinations of surface treatment and reflector material. Using no reflector material the light output increased up to 551±35% by mechanical polishing the surface compared to 100±5% for raw crystals. Etching the surface increased the light output to 441±29%. The untreated crystals had an energy resolution of 24.6±4.0%. By mechanical polishing the surface it was possible to achieve an energy resolution of 13.2±0.8%, by etching of 14.8±0.7%. In combination with BaSO4 as reflector material the maximum increase of light output has been established to 932±57% for mechanically polished and 895±61% for etched crystals. The combination with BaSO4 also caused the best improvement of the energy resolution up to 11.6±0.2% for mechanically polished and 12.2±0.3% for etched crystals. Relating to the light output there was no significant statistical difference between the two surface treatments in combination with BaSO4. In contrast to this, the statistical results of the energy resolution have shown the combination of mechanical polishing and BaSO4 as the optimum. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 60 EP - 66 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system with free running ADCs JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - A small PET system has been built up with two multichannel photomultipliers, which are attached to a matrix of 64 single LSO crystals each. The signal from each multiplier is being sampled continuously by a 12 bit ADC at a sampling frequency of 40 MHz. In case of a scintillation pulse a subsequent FPGA sends the corresponding set of samples together with the channel information and a time mark to the host computer. The data transfer is performed with a rate of 20 MB/s. On the host all necessary information is extracted from the data. The pulse energy is determined, coincident events are detected and multiple hits within one matrix can be identified. In order to achieve a narrow time window the pulse starting time is refined further than the resolution of the time mark (=25 ns) would allow. This is possible by interpolating between the pulse samples. First data obtained from this system will be presented. The system is part of developments for a much larger system and has been created to study the feasibility and performance of the technique and the hardware architecture. Y1 - 2002 SN - 0168-9002 N1 - Proceedings of the 6th International Conference on Inorganic Scin tillators and their Use in Scientific and Industrial Applications VL - 486 IS - 1-2 SP - 18 EP - 21 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Coincidence detection by digital processing of free-running sampled pulses JF - Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Coincident events in two scintillator crystals coupled to photomultipliers (PMT) are detected by processing just the digital data of the recorded pulses. For this purpose the signals from both PMTs are continuously sampled by free-running ADCs at a sampling rate of 40 MHz. For each sampled pulse the starting time is determined by processing the pulse data. Even a fairly simple interpolating algorithm results in a FWHM of about 2 ns. Y1 - 2002 SN - 0168-9002 VL - 487 IS - 3 SP - 530 EP - 534 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Pauly, F. A1 - Schroder, G. A1 - Ziemons, Karl A1 - Sievering, R. A1 - Halling, H. T1 - Preliminary studies of a micro-CT for a combined small animal PET/CT scanner JF - 2001 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - We are developing an X-ray computed tomography (CT) system which will be combined with a high resolution animal PET system. This permits acquisition of both molecular and anatomical images in a single machine. In particular the CT will also be utilized for the quantification of the animal PET data by providing accurate data for attenuation correction. A first prototype has been built using a commercially available plane silicon diode detector. A cone-beam reconstruction provides the images using the Feldkamp algorithm. First measurements with this system have been performed on a mouse. It could be shown that the CT setup fulfils all demands for a high quality image of the skeleton of the mouse. It is also suited for soft tissue measurements. To improve contrast and resolution and to acquire the X-ray energy further development of the system, especially the use of semiconductor detectors and iterative reconstruction algorithms are planned. Y1 - 2002 SN - 1082-3654 SP - 1605 EP - 1606 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - A PET system based on data processing of free-running sampled pulses JF - 2001 IEEE Nuclear Science Symposium Conference Record, Vol. 2 N2 - Within the developments for the Crystal Clear small animal PET project (CLEARPET) a dual head PET system has been established. The basic principle is the early digitization of the detector pulses by free running ADCs. The determination of the γ-energy and also the coincidence detection is performed by data processing of the sampled pulses on the host computer. Therefore a time mark is attached to each pulse identifying the current cycle of the 40 MHz sampling clock. In order to refine the time resolution the pulse starting time is interpolated from the samples of the pulse rise. The detector heads consist of multichannel PMTs with a single LSO scintillator crystal coupled to each channel. For each PMT only one ADC is required. The position of an event is obtained separately from trigger signals generated for each single channel. An FPGA is utilized for pulse buffering, generation of the time mark and for the data transfer to the host via a fast I/O-interface. Y1 - 2002 SN - 1082-3654 SP - 693 EP - 694 ER - TY - JOUR A1 - Heinrichs, U. A1 - Pietrzyk, U. A1 - Ziemons, Karl T1 - Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 JF - 2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - Within the Crystal Clear Collaboration four centres are developing 2nd generation high performance small animal PET scanners for different kinds of animals and medical applications. The first prototypes are PMT-based systems including depth of interaction (DOI) detection by using a phoswich layer of LSO and LuYAP. The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in FOVs caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN) was used. The simulations have shown that all PMT designs with one-to-one coupling of crystals have a very nonlinear axial sensitivity profile. By shifting every other PMT 1/4 of a PMT length in axial direction the sampling of the FOVs became more homogeneous. At an energy threshold of 350keV the regression coefficient increases from 0.818 for the non-shifted to 0.993 for the shifted design. Simulations of a point source centred in the FOV (threshold: 350keV) resulted in sensitivities of 4.2% for a 4×20PMT (LSO/LuYAP a 10mm) and 3.8% for a 4×16PMT (LSO/LuYAP a 8mm) ring design. The 3D-MLEM reconstruction of a point source shows the enormous improvement of resolution using a crystal double layer with DOI (3.1mm at 40mm from CFOV) instead of a 20mm single layer (11.9mm). Y1 - 2003 SN - 1082-3654 SP - 682 EP - 686 ER - TY - JOUR A1 - Heinrichs, U. A1 - Pietrzyk, U. A1 - Ziemons, Karl T1 - Design optimization of the PMT-ClearPET prototypes based on simulation studies with GEANT3 JF - IEEE Transactions on Nuclear Science N2 - Within the Crystal Clear Collaboration (CCC), four centers are developing second generation high performance small animal positron emission tomography (PET) scanners for different kinds of animals and medical applications. The first prototypes are photomultiplier tube (PMT)-based systems including depth of interaction (DOI) detection by using a phoswich layer of lutetium oxyorthosilicate (LSO) and lutetium yttrium aluminum perovskite (LuYAP). The aim of these simulation studies is to optimize sensitivity and spatial resolution of given designs, which vary in fields of view (FOVs) caused by different detector configurations (ring/octagon) and sizes. For this purpose the simulation tool GEANT3 (CERN, Geneva, Switzerland) was used. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 5 SP - 1428 EP - 1432 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - 2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 1082-3654 SP - 1636 EP - 1639 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - IEEE Transactions on Nuclear Science N2 - A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 3 SP - 344 EP - 347 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chaziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different microCT scanner configurations by GEANT4 simulations JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - This study has been performed to design the combination of the new ClearPET TM (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal Positron Emission Tomography (PET) system, with a microComputed Tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2004 SN - 1082-3654 SP - 2989 EP - 2993 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. T1 - The ClearPET TM LSO/LuYAP phoswich scanner: a high performance small animal PET system JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes. Y1 - 2004 SN - 1082-3654 SP - 1728 EP - 1732 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Brökel, M. A1 - Fuss, L. A1 - Larue, H. A1 - Parl, C. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - The ClearPET data acquisition JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - Within the Crystal Clear Collaboration a modular system for a small animal PET scanner (ClearPET™) has been developed. The modularity allows the assembly of scanners of different sizes and characteristics in order to fit the specific needs of the individual member institutions. Now a first demonstrator is being completed in Julich. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to multi-channel photomultipliers (PMTs). A free-running ADC digitizes the signal from the PMT and the complete scintillation pulses are sampled by an FPGA and sent with 20 MB/S to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. An advantage of that is that the coincidence window and the dimensions of the field of view can be adjusted easily. The ClearPET™ demonstrator is equipped with 10240 crystals on 80 PMTs. This paper presents an overview of the data acquisition system. Y1 - 2004 SN - 1082-3654 SP - 3097 EP - 3100 ER - TY - JOUR A1 - Christ, D. A1 - Hollendung, A. A1 - Larue, H. A1 - Parl, C. A1 - Streun, M. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. T1 - Homogenization of the MultiChannel PM gain by inserting light attenuating masks JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - MultiChannel Photomultipliers (PM), like the R7600-00-M64 or R5900-00-M64 from Hamamatsu, are often chosen as photodetectors in high-resolution positron emission tomography (PET). A major problem of this PM is the nonuniform channel gain. In order to solve this problem, light attenuating masks were created. The aim of the masks is a homogenization of the output of all 64 channels using different hole sizes at the channel positions. The hole area, which is individually defined for the different channels, is inversely proportional to the channel gain. The measurements by inserting light attenuating masks improved a homogenization to a ratio of 1:1.2. Y1 - 2004 SN - 1082-3654 SP - 2382 EP - 2385 ER - TY - JOUR A1 - Ziemons, Karl A1 - Heinrichs, U. A1 - Streun, M. A1 - Pietrzyk, U. T1 - Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. Y1 - 2004 SN - 1082-3654 SP - 3053 EP - 3056 ER - TY - JOUR A1 - Auffray, E. A1 - Bruyndonckx, P. A1 - Devroede, O. A1 - Fedorov, A. A1 - Ziemons, Karl T1 - The ClearPET project JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view. Y1 - 2004 SN - 0168-9002 N1 - Proceedings of the 2nd International Conference on Imaging Technologies in Biomedical Sciences VL - 527 IS - 1-2 SP - 171 EP - 174 ER - TY - JOUR A1 - Streun, M. A1 - Christ, D. A1 - Hellendung, A. A1 - Larue, H. A1 - Ziemons, Karl A1 - Halling, H. T1 - Effects of crosstalk and gain nonuniformity using multichannel PMTs in the Clearpet® scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The ClearPET® scanners developed by the Crystal Clear Collaboration use multichannel PMTs as photodetectors with scintillator pixels coupled individually to each channel. In order to localize an event each channel anode is connected to a comparator that triggers when the anode signal exceeds a common predefined threshold. Two major difficulties here are crosstalk of light and the gain nonuniformity of the PMT channels. Crosstalk can generate false triggering in channels adjacent to the actual event. On the one hand this can be suppressed by sufficiently increasing the threshold, but on the other hand a threshold too high can already prevent valid events on the lower gain channels from being detected. Finally, both effects restrict the dynamic range of pulse heights that can be processed. The requirements to the dynamic range are not low as the ClearPET® scanners detect the depth of interaction by phoswich pixels consisting of LSO and Lu0.7Y0.3AP, two scintillators with different light yields. We will present a model to estimate the achievable dynamic range and show solutions to increase it. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 402 EP - 405 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, E. A1 - Barbier, R. A1 - Brandenburg, G. A1 - Bruyndonckx, P. T1 - The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view. Preliminary data shows a correct identification of the crystal layer about (98±1)%. Typically the energy resolution is (23.3±0.5)% for the luyap layer and (15.4±0.4)% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 307 EP - 311 ER - TY - JOUR A1 - Beer, S. A1 - Streun, M. A1 - Hombach, T. A1 - Buehler, J. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - Design and initial performance of PlanTIS: a high-resolution positron emission tomograph for plants JF - Physics in Medicine and Biology N2 - Positron emitters such as 11C, 13N and 18F and their labelled compounds are widely used in clinical diagnosis and animal studies, but can also be used to study metabolic and physiological functions in plants dynamically and in vivo. A very particular tracer molecule is 11CO2 since it can be applied to a leaf as a gas. We have developed a Plant Tomographic Imaging System (PlanTIS), a high-resolution PET scanner for plant studies. Detectors, front-end electronics and data acquisition architecture of the scanner are based on the ClearPET™ system. The detectors consist of LSO and LuYAP crystals in phoswich configuration which are coupled to position-sensitive photomultiplier tubes. Signals are continuously sampled by free running ADCs, and data are stored in a list mode format. The detectors are arranged in a horizontal plane to allow the plants to be measured in the natural upright position. Two groups of four detector modules stand face-to-face and rotate around the field-of-view. This special system geometry requires dedicated image reconstruction and normalization procedures. We present the initial performance of the detector system and first phantom and plant measurements. Y1 - 2010 U6 - https://doi.org/10.1088/0031-9155/55/3/006 SN - 1361-6560 VL - 55 IS - 3 SP - 635 EP - 646 PB - IOP CY - Bristol ER - TY - JOUR A1 - Herzog, Hans A1 - Pietrzyk, Uwe A1 - Shah, N. Jon A1 - Ziemons, Karl T1 - The current state, challenges and perspectives of MR-PET JF - Neuroimage N2 - Following the success of PET/CT during the last decade and the recent increasing proliferation of SPECT/CT, another hybrid imaging instrument has been gaining more and more interest: MR-PET. First combined, simultaneous PET and MR studies carried out in small animals demonstrated the feasibility of the new approach. Concurrently, some prototypes of an MR-PET scanner for simultaneous human brain studies have been built, their performance is being tested and preliminary applications have already been shown. Through this pioneering work, it has become clear that advances in the detector design are necessary for further optimization. Recently, the different issues related to the present state and future prospects of MR-PET were presented and discussed during an international 2-day workshop at the Forschungszentrum Jülich, Germany, held after, and in conjunction with, the 2008 IEEE Nuclear Science Symposium and Medical Imaging Conference in Dresden, Germany on October 27–28, 2008. The topics ranged from small animal MR-PET imaging to human MR-BrainPET imaging, new detector developments, challenges/opportunities for ultra-high field MR-PET imaging and considerations of possible future research and clinical applications. This report presents a critical summary of the contributions made to the workshop. Y1 - 2010 U6 - https://doi.org/10.1016/j.neuroimage.2009.10.036 SN - 1053-8119 VL - 49 IS - 3 SP - 2072 EP - 2082 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Parl, C. A1 - Larue, H. A1 - Streun, M. A1 - Ziemons, Karl T1 - Double-side-readout technique for SiPM-matrices JF - 2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit. Y1 - 2011 SN - 1095-7863 SP - 1486 EP - 1487 PB - IEEE CY - New York ER - TY - CHAP A1 - Streun, M. A1 - Al-Kaddoum, R. A1 - Parl, C. A1 - Pietrzyk, U. A1 - Ziemons, Karl A1 - Waasen, S. van T1 - Simulation studies of optical photons in monolithic block scintillators T2 - 2011 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - The interest in PET detectors with monolithic block scintillators is growing. In order to obtain high spatial resolutions dedicated positioning algorithms are required. But even an ideal algorithm can only deliver information which is provided by the detector. In this simulation study we investigated the light distribution on one surface of cuboid LSO scintillators of different size. Scintillators with a large aspect ratio (small footprint and large height) showed significant position information only for a minimum interaction depth of the gamma particle. The results allow a quantitative estimate for a useful aspect ratio. Y1 - 2012 SN - 978-1-4673-0120-6 (electronic ISBN) SN - 978-1-4673-0118-3 (print ISBN) U6 - https://doi.org/10.1109/NSSMIC.2011.6154621 SP - 1380 EP - 1382 PB - IEEE CY - New York ER - TY - JOUR A1 - Gebhardt, Andreas A1 - Fateri, Miranda T1 - 3D printing and its applications JF - RTejournal - Forum für Rapid Technologie N2 - Eine zunehmende Anzahl von Artikeln in Publikumszeitschriften und Journalen rückt die direkte Herstellung von Bauteilen und Figuren immer mehr in das Bewusstsein einer breiten Öffentlichkeit. Leider ergibt sich nur selten ein einigermaßen vollständiges Bild davon, wie und in welchen Lebensbereichen diese Techniken unseren Alltag verändern werden. Das liegt auch daran, dass die meisten Artikel sehr technisch geprägt sind und sich nur punktuell auf Beispiele stützen. Dieser Beitrag geht von den Bedürfnissen der Menschen aus, wie sie z.B. in der Maslow’schen Bedürfnispyramide strukturiert dargestellt sind und unterstreicht dadurch, dass 3D Printing (oder Additive Manufacturing resp. Rapid Prototyping) bereits alle Lebensbereiche erfasst hat und im Begriff ist, viele davon zu revolutionieren. N2 - An increasing amount of popular articles focus on making models and sculptures by 3D Printing thus making more and more even private users aware of this technology. Unfortunately they mostly draw an incomplete picture of how our daily life will be influenced by this new technology. Often this is caused by a very technical point of view based on not very representative examples. This article focuses on the peoples needs as they have been structured by the so-called Maslow pyramid. Doing so, it underlines that 3D Printing (called Additive Manufacturing or Rapid Prototyping as well) already touches all aspects of life and is about to revolutionize most of them. Y1 - 2013 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0009-2-35626 SN - 1614-0923 VL - 10 IS - 1 PB - Fachhochschule Aachen CY - Aachen ER - TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Suso, Henri-Pierre A1 - Rysstad, Gunnar A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes JF - Physica status solidi (a) N2 - A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests. KW - calorimetric gas sensor;hydrogen peroxide;wireless sensor system Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200920 SN - 1862-6319 VL - 210 IS - 5 SP - 877 EP - 883 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chatziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different MicroCT scanner configurations by GEANT4 simulations JF - IEEE Transactions on Nuclear Science N2 - This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2005 SN - 0018-9499 VL - 52 IS - 1 SP - 188 EP - 192 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - The data acquisition system of ClearPET neuro - a small animal PET scanner JF - IEEE Transactions on Nuclear Science N2 - The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 3 SP - 700 EP - 703 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Weber, S. A1 - Streun, M. A1 - Parl, C. A1 - Ziemons, Karl T1 - High resolution imaging with ClearPET™ Neuro - first animal images JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance. Y1 - 2006 SN - 1082-3654 SP - 1641 EP - 1644 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - Timemark correction for the ClearPET™ scanners JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented Y1 - 2006 SN - 1082-3654 SP - 2057 EP - 2060 ER - TY - CHAP A1 - Gerhards, Michael A1 - Sander, Volker A1 - Belloum, Adam T1 - Seamlessly enabling the use of cloud resources in workflows T2 - Cloud Computing 2013 : The Fourth International Conference on Cloud Computing, GRIDs, and Virtualization : May 27 - June 1, 2013 - Valencia, Spain Y1 - 2013 SN - 978-1-61208-271-4 SP - 108 EP - 114 PB - Curren CY - Red Hook, NY ER - TY - JOUR A1 - Jens, Otto A1 - Kaldenhoff, E. A1 - Kirschner-Hermanns, R. A1 - Mühl, Thomas A1 - Klinge, Uwe T1 - Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates JF - Journal of biomedical materials research. Part A N2 - Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome. Y1 - 2014 U6 - https://doi.org/10.1002/jbm.a.34767 SN - 1552-4965 VL - 102 IS - 4 SP - 1079 EP - 1084 PB - Wiley CY - New York ER - TY - CHAP A1 - Schwarzer, Klemens A1 - Vieira, Maria Eugenia A1 - Müller, Christoph A1 - Lehmann, Harry A1 - Coutinho, Lecimara T1 - Modular solar thermal desalination system with flat plate collector T2 - RIO 3 - World Climate & Energy Event : proceedings of the international conference held in Rio de Janeiro, Brazil, 1 -5 december 2003 / chief-ed.: Stefan Krauter ... Y1 - 2003 SN - 85-902710-2-1 SP - 281 EP - 286 PB - Krauter CY - Rio de Janeiro ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Ichimura, Hiroki A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel JF - Sensors and actuators. B: Chemical N2 - The chemical imaging sensor is a device to visualize the spatial distribution of chemical species based on the principle of LAPS (light-addressable potentiometric sensor), which is a field-effect chemical sensor based on semiconductor. In this study, the chemical imaging sensor has been applied to investigate the ion profile of laminar flows in a microfluidic channel. The chemical images (pH maps) were collected in a Y-shaped microfluidic channel while injecting HCl and NaCl solutions into two branches. From the chemical images, it was clearly observed that the injected solutions formed laminar flows in the channel. In addition, ion diffusion across the laminar flows was observed, and the diffusion coefficient could be derived by fitting the pH profiles to the Fick's equation. Y1 - 2013 U6 - https://doi.org/10.1016/j.snb.2013.04.057 SN - 1873-3077 (E-Journal); 0925-4005 (Print) N1 - Part of special issue "Selected Papers from the 26th European Conference on Solid-State Transducers" VL - 189 SP - 240 EP - 245 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Schütz, P. A1 - Breuer, M. A1 - Höfken, Hans-Wilhelm A1 - Schuba, Marko T1 - Malware proof on mobile phone exhibits based on GSM/GPRS traces T2 - The Second International Conference on Cyber Security, Cyber Peacefare and Digital Forensic (CyberSec 2013) : 04.03. - 06.03.2013, Kuala Lumpur, Malaysia Y1 - 2013 SN - 978-0-9853483-7-3 SP - 89 EP - 96 PB - The Society of Digital Information and Wireless Communication ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Trattner, Barbara A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Stütz, Evamaria A1 - Schmitt-Landsiedel, Doris A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment JF - Sensors and actuators. B: Chemical Y1 - 2013 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - Vol. 182 SP - 58 EP - 65 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Späte, Frank A1 - Hafner, B. A1 - Schwarzer, Klemens T1 - A system for solar process heat for decentralized applications in developing countries T2 - ISES 1999 Solar World Congress, Jerusalem, Israel, July 4-9, 1999 : conference proceedings / ed. Gershon Grossman. Vol. 3 Y1 - 2000 SN - 0-080-043895-4 SP - 236 EP - 291 PB - Elsevier CY - Oxford ER - TY - JOUR A1 - Meliß, Michael A1 - Neskakis, A. A1 - Plettner-Marliani, J. A1 - Lange, C. A1 - Hövelmann, A. A1 - Schumacher, J. T1 - Waste water recycling supplied by renewable energies : basic conditions and possible treatment technologies JF - Renewable energy. Vol. 14 (1998), iss. 1-4. 6th Arab International Solar Energy Conference: Bringing Solar Energy into the Daylight, Muscat, Sultanate of Oman, 29.03.-01.04.1998 Y1 - 1998 SN - 1879-0682 (E-Book); 0960-1481 (Print) SP - 325 EP - 331 ER - TY - JOUR A1 - Wemhöner, Carsten A1 - Hafner, Bernd A1 - Schwarzer, Klemens T1 - Simulation of solar thermal systems with CARNOT blockset in the environment MATLAB-Simulink Y1 - 2000 SP - 1 EP - 6 ER - TY - CHAP A1 - Fredebeul-Krein, Markus A1 - Steingröver, Markus T1 - Enhancing broadband development and internet usages for improving networks and services in APEC member economies: Bridging the digital divide T2 - The 19th ITS Biennial Conference 2012 “Moving Forward with Future Technologies: Opening a Platform for All” 18 - 21 November 2012, Thailand Y1 - 2013 PB - ITS CY - Bangkok ER - TY - JOUR A1 - Vitusevich, S. A. A1 - Förster, Arnold A1 - Lüth, H. A1 - Belyaev, A. E. A1 - Danylyuk, S. V. A1 - Konakova, R. V. A1 - Sheka, D. I. T1 - Resonant spectroscopy of electric-field-induced superlattices JF - Journal of Applied Physics. 90 (2001), H. 6 Y1 - 2001 SN - 1089-7550 U6 - https://doi.org/10.1063/1.1392956 SP - 2857 EP - 2861 ER - TY - JOUR A1 - Stock, J. A1 - Malindretos, J. A1 - Indlekofer, K.M. A1 - Pöttgens, Michael A1 - Förster, Arnold A1 - Lüth, Hans T1 - A Vertical Resonant Tunneling Transistor for Application in Digital Logic Circuits JF - IEEE Transactions on Electron Devices (T-ED). 48 (2001), H. 6 Y1 - 2001 SN - 0018-9383 SP - 1028 EP - 1032 ER - TY - JOUR A1 - Schwarzer, Klemens A1 - Schlenger, Barbara J. T1 - Investigation of fission product aerosol behavior in an HTR containment during severe core-heatup accidents / Barbara J. Schlenger ; K. Schwarzer JF - Tagungsbericht : Maritim Kongresszentrum, 17. - 19. Mai '88 Travemünde / Kerntechnische Gesellschaft e.V.; Deutsches Atomforum e.V. [Red.: K. G. Bauer] Y1 - 1988 SN - 0720-9207 N1 - Jahrestagung Kerntechnik <1988, Lübeck-Travemünde> ; Annual Meeting of Nuclear Technology <1988, Lübeck-Travemünde> SP - 179 EP - 182 PB - Inforum CY - Bonn ER - TY - JOUR A1 - Hodel, U. A1 - Orzati, A. A1 - Marso, M. A1 - Homann, O. A1 - Fox, A. A1 - Hart, A. v. d. A1 - Förster, Arnold A1 - Kordos, P. A1 - Lüth, H. T1 - A novel InAlAs/InGaAs layer structure for monolithically integrated photoreceiver JF - Conference Proceedings: 2000 International Conference on Indium Phosphide and related materials Y1 - 2000 SN - 0-7803-6320-5 N1 - International Conference on Indium Phosphide and Related Materials <12, 2000, Williamsburg, Va.> SP - 466 EP - 469 PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Hoskens, R.C.P. A1 - Roer, T.G. van de A1 - Tolstikhin, V.I. A1 - Förster, Arnold T1 - Hot electron injection laser: vertically integrated transistor-laser structure for high-speed, low-chirp direct modulation JF - LEOS 2000 : 2000 IEEE annual meeting conference proceedings; 13th annual meeting; IEEE Lasers and Electro-Optics Society 2000 annual meeting; 13-16 November 2000, The Westin Rio Mar Beach, Rio Grande, Puerto Rico. Vol. 2 Y1 - 2000 SN - 0-7803-5947-X N1 - 2000 IEEE LEOS annual meeting SP - 444 EP - 445 PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Hoskens, R. C. P. A1 - Tolstikhin, V.I. A1 - Förster, Arnold A1 - Roer, T.G. van de T1 - Vertically integrated transistor-laser structure, take 2 JF - WOCSDICE 2000, 24th Workshop on Compound Semiconductor Devices and Integrated Circuits held in Europe : May 29 - June 02, 2000, Aegean Sea, Greece. Y1 - 2000 SN - 0970311109 N1 - WOCSDICE ; (24, 2000) Workshop on Compound Semiconductor Devices and Integrated Circuits held in Europe ; (24 : ; 2000.05.29-06.02) PB - Univ. of Michigan CY - Ann Arbor, Mich. ER - TY - JOUR A1 - Darmo, J. A1 - Schäffer, F. A1 - Förster, Arnold A1 - Kordos, P. T1 - Beryllium doped low-temperature-grown MBE GaAs: material for photomixing in the THz frequency range JF - ASDAM 2000 : conference proceedings / edited by Jozef Osvald ... [et al.] Y1 - 2000 SN - 0780359399 N1 - International Conference on Advanced Semiconductor Devices and Microsystems ; (3rd : ; 2000 : ; Smolenice, Slovakia) SP - 147 EP - 150 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Griebel, M. A1 - Indlekofer, K.M. A1 - Lüth, H. T1 - Single electron transport in resonant tunnelling diodes laterally confined by ion implantation. Griebel, M.; Indlekofer, K.M.; Förster, A.; Lüth, H. JF - Journal of Physics D: Applied Physics. 32 (1999), H. 14 Y1 - 1999 SN - 1361-6463 SP - 1729 EP - 1733 ER - TY - JOUR A1 - Schmidt, R. A1 - Tonnesmann, A. A1 - Förster, Arnold A1 - Grimm, M. A1 - Kordos, P. A1 - Lüth, H. T1 - Metamorphic InAlAs/InGaAs HEMT's on GaAs substrates using an InP buffer layer JF - 8th IEEE International Symposium on High Performance Electron Devices for Microwave and Optoelectronic Applications : EDMO 2000 ; [13 - 14 November 2000, University of Glasgow] / organised by Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow Scotland. MTT/ED/AP/LEO Societies Joint Chapter, United Kingdom and Republic of Ireland Section. With technical co-sponsorship from IEEE Electron Device Society Y1 - 2000 SN - 0-7803-6550-X N1 - EDMO <8, 2000, Glasgow> ; University / Department of Electronics and Electrical Engineering ; IEEE catalog number 00TH8534 SP - 95 EP - 98 PB - IEEE Operations Center CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Betko, J. A1 - Morvic, M. A1 - Novak, J. T1 - Magnetoresistance in low-temperature grown molecular-beam epitaxial GaAs. Betko, J.; Morvic, M.; Novak, J.; Förster, A.; Kordos, P. JF - Journal of Applied Physics. 86 (1999), H. 11 Y1 - 1999 SN - 1089-7550 SP - 6243 EP - 6248 ER - TY - JOUR A1 - Förster, Arnold A1 - Morvic, M. A1 - Betko, J. A1 - Novak, J. T1 - Characterization of low-temperature GaAs by conductivity, Hall effect and magnetoresistance measurements. Morvic, M., Betko, J.; Novak, J.; Förster, A.; Kordos, P. JF - 2nd Symposium on Non-Stoichiometric III-V Compounds : [4th - 6th October 1999, Erlangen] / [ed. by T. Marek ...] Friedrich-Alexander-Universität Erlangen-Nürnberg Y1 - 1999 SN - 3-932392-19-1 N1 - Symposium on Non-Stoichiometric III-V Compounds <2, 1999, Erlangen> SP - 79 EP - 85 PB - Lehrstuhl für Mikrocharakterisierung CY - Erlangen ER - TY - JOUR A1 - Förster, Arnold A1 - Kordos, P. A1 - Marso, M. A1 - Rüders, F. T1 - 550 GHz bandwidth photodetector on low-temperature grown molecular-beam epitaxial GaAs. Kordos, P., Förster, A.; Marso, M.; Rüders, F. JF - Electronics Letters. 34 (1998), H. 1 Y1 - 1998 SN - 1350-911X SP - 119 EP - 120 ER - TY - JOUR A1 - Vitusevich, S. A. A1 - Förster, Arnold A1 - Reetz, W. A1 - Lüth, H. A1 - Belyaev, A. E. A1 - Danylyuk, S. V. T1 - Fine structure of photoresponse spectra in a double-barrier resonant tunnelling diode JF - Nanotechnology. 11 (2000), H. 4 Y1 - 2000 SN - 1361-6528 SP - 305 EP - 308 ER - TY - JOUR A1 - Fredebeul-Krein, Markus A1 - Vogel, Erika T1 - Underground Storage Facilities in the German natural gas market: A need for access regulation to ensure competition? JF - Zeitschrift für Energiewirtschaft. 30 (2006), H. 4 Y1 - 2006 SN - 0343-5377 SP - 257 EP - 270 ER - TY - JOUR A1 - Förster, Arnold A1 - Hartmann, A. A1 - Dieker, Ch. A1 - Hollfelder, M. T1 - Spontaneous formation of tilted AlGaAS/GaAs superlattice during AlGaAs growth. Hartmann, A.; Dieker, Ch.; Hollfelder, M.; Hardtdegen, H.; Förster, A.; Lüth, H. JF - Applied Surface Science. 123-124 (1998) Y1 - 1998 SN - 0169-4332 N1 - = Proceedings of the Sixth International Conference on the Formation of Semiconductor Interfaces SP - 704 EP - 709 ER - TY - JOUR A1 - Schwarzer, Klemens A1 - Werner, M. A1 - Hartz, T. T1 - Lacasa - an instrument for the energy analysis and optimisation of buildings including technical equipment JF - Proceedings / organised by: ISES Europe ... [Ed.: Deutsche Gesellschaft für Sonnenenergie e.V. - DGS, Munich ; PSE GmbH - Forschung Entwicklung Marketing, Freiburg]. - Vol. 2 Y1 - 2004 SN - 3-9809656-2-7 N1 - EuroSun <5, 2004, Freiburg, Breisgau> ; Internationales Sonnenforum <14, 2004, Freiburg, Breisgau> ; Deutsche Gesellschaft für Sonnenenergie ; CD-ROM-Ausg.: ISBN 3-9809656-4-3 SP - 2-489-2-494 PB - PSE CY - Freiburg [Breisgau] ER - TY - CHAP A1 - Helsper, Christoph A1 - Fissan, H. J. A1 - Franzen, H. ED - Benarie, Michel M. T1 - Particle Size Distributions of Combustion Aerosols T2 - Atmospheric Pollution 1978 : Proceedings of the 13th International Colloquium; 25-28 April 1978; Paris, France; Edited by Michel M. Benarie N2 - It has been observed that carcinogenic polycyclic aromatic hydrocarbons (PAH) are present in the atmosphere. Combustion processes are considered the most important sources for PAH. Among these, the burning of coal produces the highest emission, but in cities with high traffic density and low meteorological exchange activities, vehicle emissions determine the immission situation, especially in narrow streets. For estimating the potential health effects caused by PAH, it is sufficient to characterize the emission of PAH with respect to their physical state, concentrations, and, as far as the particulate phase is concerned, size distribution. The size distribution is important for transport phenomena, inhalation, and deposition in the respiratory tract. These parameters mainly depend on the combustion system, on system operating conditions, on the exhaust system, and on exhaust cooling conditions. At exhaust-gas temperatures in the range of ambient air temperatures, almost the whole emission of PAH is made up of particulate matter. Y1 - 1978 SN - 0-444-41691-9 U6 - https://doi.org/10.1016/S0166-1116(08)71583-8 SP - 263 EP - 266 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Kayatekin, Muammer B. A1 - Uysal, N. A1 - Resmi, H. T1 - Does antioxidant supplementation alter the effects of acute exercise on erythrocyte aggregation, deformability and endothelium adhesion in untrained rats? Kayatekin, Muammer B.; Uysal N.; Resmi, H.; Bediz, Seref C.; Temiz Artmann, A.; Genç, S.; Tugyan, K. JF - International Journal for Vitamin and Nutrition Research. 75 (2005), H. 4 Y1 - 2005 SN - 0300-9831 SP - 243 EP - 250 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Resmi, Halil A1 - Akhunlar, Hülya A1 - Güner, Gül T1 - In vitro effects of high glucose concentrations on membrane protein sulfhydryl oxidation, G-actin and deformability of human erythrocytes. Resmi, Halil ; Akhunlar, Hülya ; Temiz Artmann, Aysegül ; Güner, Gül JF - Cell biochemistry and function. 23 (2005), H. 3 Y1 - 2005 SN - 0263-6484 SP - 163 EP - 168 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Cavdar, C. A1 - Yenicerioglu, Y. A1 - Caliskan, S. T1 - The effects of intravenous iron treatment on oxidant stress and erythrocyte deformability in haemodialysis patients. Cavdar, C.; Temiz, A.; Yenicerioglu, Y.; Caliskan, S.; Celik, A.; Sifil, A.; Onvural, B.; Camsari, T. JF - Scandinavian Journal of Urology and Nephrology. 37 (2003), H. 1 Y1 - 2003 SN - 0036-5599 SP - 77 EP - 82 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Yalcin, Ozlem A1 - Resmi, Halil A1 - Baskurt, Oguz K. T1 - Can white blood cell activation be one of the major factors that affect hemorheological parameters during and after exercise? JF - Clinical Hemorheology and Microcirculation. 26 (2002), H. 3 Y1 - 2002 SN - 1386-0291 N1 - = The 11th European Symposium on Clinical Hemorheology, Rouen, France, 19-22 September 2000 SP - 189 EP - 193 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, Oguz K. A1 - Pekcetin, C. A1 - Kandemir, F. T1 - Leukocyte activation, oxidant stress and red blood cell properties after acute, exhausting exercise in rats. Temiz, A.; Baskurt, O. K., Pekcetin, C.; Kandemir, F.; Güre, A. JF - Clinical Hemorheology and Microcirculation. 22 (2000), H. 4 Y1 - 2000 SN - 1386-0291 SP - 253 EP - 259 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Yolcuoglu, B. A1 - Onal, M. A. A1 - Sipahi, O. T1 - The effect of skin transplantation on tumour growth in mice. Yolcuoglu, B.; Onal, M. A.; Sipahi, O.; Temiz, A.; Pekcetin, C.; Acikgöz, O.; Kar, H.; Güre A. JF - The American Journal of Surgery. 178 (1999), H. 4 Y1 - 1999 SN - 0002-9610 SP - 329 EP - 330 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Ates, H. A1 - Üretmen, Ö. A1 - Andac, K. T1 - Erythrocyte deformability in high-tension and normal tension glaucoma. Ates, H.; Üretmen, Ö.; Temiz, A.; Andac, K. JF - International Ophthalmology. 22 (1998), H. 1 Y1 - 1998 SN - 0165-5701 SP - 7 EP - 12 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Meiselman, H. J. T1 - Effect of superoxide anions on red blood cell rheologic properties. Baskurt, O. K.; Temiz, A.; Meiselman, H. J. JF - Free Radical Biology and Medicine. 24 (1998), H. 1 Y1 - 1998 SN - 0891-5849 SP - 102 EP - 110 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Meiselman, H. J. T1 - Red blood cell aggregation in experimental sepsis . Baskurt, O. K.; Temiz, A.; Meiselman, H. J. JF - Journal of Laboratory and Clinical Medicine. 130 (1997), H. 2 Y1 - 1997 SN - 0022-2143 SP - 183 EP - 190 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Edremitlioglu, M. T1 - Effect of erythrocyte deformability on myocardial hematocrit gradient. Baskurt, O.K.; Edremitlioglu, M.; Temiz, A. JF - American Journal of Physiology: Heart and Circulatory Physiology. 268 (1995), H. 1 Y1 - 1995 SN - 0363-6135 SP - 260 EP - 264 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Baskurt, O. K. A1 - Edremitlioglu, M. T1 - In vitro effects of in vivo activated leukocytes on red blood cell filterability and lipid peroxidation. Baskurt, O.K.; Edremitlioglu, M.; Temiz, A. JF - Clinical Hemorheology. 14 (1994), H. 4 Y1 - 1994 SP - 591 EP - 596 ER - TY - JOUR A1 - Temiz Artmann, Aysegül A1 - Akhisaroglu, M. A1 - Sercan, Z. A1 - Kayatekin, B. M. T1 - Adhesion of Erythrocytes to Endothelial Cells After Acute Exercise: Differences in Red Blood Cells from Juvenile and Adult Rats. Temiz Artmann, A.; Akhisaroglu, M.; Sercan, Z.; Kayatekin, BM.; Yorukoglu, K.; Kirkali, G. JF - Physiological Research (2005) Y1 - 2005 SN - 0862-8408 N1 - pre-press article ER - TY - JOUR A1 - Thielemann, Frank A1 - Bock, Jürgen T1 - Organization and management of German-Russian joint ventures. Bock, Jürgen; Thielemann, Frank JF - International journal of technology management. 9 (1994), H. 8 Y1 - 1994 SN - 0267-5730 SP - 864 EP - 879 ER - TY - BOOK A1 - Thielemann, Frank A1 - Staudt, Erich A1 - Kriegesmann, Bernd T1 - Joint-ventures. Staudt, Erich; Kriegesmann, Bernd; Thielemann, Frank Y1 - 1994 N1 - Berichte aus der angewandten Innovationsforschung ; 133 PB - Inst. für Angewandte Innovationsforschung e.V. CY - Bochum ER - TY - JOUR A1 - Förster, Arnold A1 - Bertuccio, G. A1 - Pullia, A. T1 - Pixel X-ray detectors in epitaxial gallium arsenide withhigh-energy resolution capabilities (Fano factor experimentaldetermination) / G. Bertuccio ; A. Pullia ; J. Lauter ; A. Förster ... JF - IEEE transactions on nuclear science. 44 (1997), H. 1 Y1 - 1997 SN - 0018-9499 SP - 1 EP - 5 ER - TY - JOUR A1 - Förster, Arnold A1 - Morvic, M. A1 - Betko, J. T1 - On the hopping and band conductivity in molecular-beam epitaxial low-temperature grown GaAs / M. Morvic ; J. Betko ; J. Novák ... A. Förster JF - Physica status solidi / B, Basic research. 205 (1998), H. 1 Y1 - 1998 SN - 1521-3951 SP - 125 EP - 128 ER - TY - JOUR A1 - Fredebeul-Krein, Markus T1 - Adopting a coherent institutional framework for the Ukrainian telecom sector: Lessons to be learnt from European and German experience JF - Zerkalo Nedeli (2003) Y1 - 2003 N1 - (Ukrainian Journal) ER - TY - JOUR A1 - Fredebeul-Krein, Markus T1 - Regulating Prices of Unbundled Access to the Local Loop: A German Case Study JF - Telekomunikacja i techniki informacyjne (2002) Y1 - 2002 SN - 1640-1549 N1 - Telecommunications and Information Technologies SP - 10 EP - 18 ER - TY - JOUR A1 - Förster, Arnold A1 - Brugger, H. A1 - Meiners, U. T1 - High quality GaAs-based resonant tunneling diodes for high frequency device applications / H. Brugger ; U. Meiners ; C. Wölk ... A. Förster ... JF - Proceedings : August 5 - 7, 1991, Cornell University, Ithaca, New York / R. J. Trew, General Chairman Y1 - 1991 SN - 0-7803-0491-8 N1 - Cornell Conference on Advanced Concepts in High Speed Semiconductor Devices and Circuits <1991, Ithaca, NY> SP - 39 EP - ff. PB - Inst. of Electrical and Electronics Engineers CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Dubecky, F.. A1 - Darmo, J. T1 - Investigation of deep-level states in bulk and low temperature MBE semiinsulating GaAs by admittance transient spectroscopy / F. Dubecky ; J. Darmo ; M. Darviras ; A. Förster ... JF - Semi-insulating III-V materials, Ixtapa, Mexico 1992 : proceedings of the 7th Conference on Semi-insulating III-V Materials, Ixtapa, Mexico, 21 - 24 April 1992 / ed. by C. J. Miner ... Y1 - 1994 SN - 0-7503-0242-9 N1 - Conference on Semi-Insulating III-V Materials <7, 1992, Ixtapa> SP - 265 EP - 272 PB - Inst. of Physics Publ. CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Dieker, C. A1 - Gerthsen, D. T1 - Microstructure of the AlAs/GaAs and AlAs/InGaAs resonant tunneling diodes and its correlation with the electrical properties / C. Dieker ; D. Gerthsen ; A. Förster ... JF - Microscopy of semiconducting materials 1993 : proceedings of the Royal Microscopical Society Conference held at Oxford University, 5 - 8 April 1993 / ed. by A. G. Cullis ... - (Conference series / Institute of Physics ; 134) Y1 - 1993 SN - 0-7503-0290-9 N1 - Royal Microscopical Society Conference on Microscopy of Semiconducting Materials <8, 1993, Oxford> ; MSM <8, 1993, Oxford> SP - 253 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Walther, T. A1 - Gerthsen, D. A1 - Carius, Reinhard A1 - Förster, Arnold T1 - AlAs/GaAs Quantum well structures: Interface properties investigated by high-resolution transmission electron microscopy and photoluminescence spectroscopy / T. Walther ; D. Gerthsen ; R. Carius ; A. Förster ... JF - Microscopy of semiconducting materials 1993 : proceedings of the Royal Microscopical Society Conference held at Oxford University, 5 - 8 April 1993 / ed. by A. G. Cullis ... - (Conference series / Institute of Physics ; 134) Y1 - 1993 SN - 0-7503-0290-9 N1 - Royal Microscopical Society Conference on Microscopy of Semiconducting Materials <8, 1993, Oxford> ; MSM <8, 1993, Oxford> SP - 449 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Kordos, P. A1 - Betko, J. T1 - Electrical and structural characterization of MBE GaAs grown at temperatures between 200 and 600 °C / P. Kordos ; J. Betko; A. Förster ... JF - Compound semiconductors, 1994 : proceedings of the twenty-first International Symposium on Compound Semiconductors held in San Diego, California, 18 - 22 September, 1994 / ed. by Herb Goronkin ... - (Conference series / Institute of Physics ; 141) Y1 - 1995 SN - 0-7503-0226-7 N1 - International Symposium on Compound Semiconductors <21, 1994, San Diego, Calif.> ; Institute of Physics SP - 295 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Hardtdegen, Hilde A1 - Ungermanns, C. T1 - Comparative investigation of electrical and optical characteristics of AlxGa1-xAs/GaAs structures deposited by LP-MOVPE and MBE / H. Hardtdegen ; M. Hollfelder ; C. Ungermanns ... A. Förster ... JF - Compound semiconductors, 1994 : proceedings of the twenty-first International Symposium on Compound Semiconductors held in San Diego, California, 18 - 22 September, 1994 / ed. by Herb Goronkin ... - (Conference series / Institute of Physics ; 141) Y1 - 1995 SN - 0-7503-0226-7 N1 - International Symposium on Compound Semiconductors <21, 1994, San Diego, Calif.> ; Institute of Physics SP - 81 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Tillmann, K. A1 - Gerthsen, D. T1 - Morphological transformations of MBE-grown In0.6Ga0.4As island on GaAs(001) substrates / K. Tillmann ; D. Gerthsen ; P. Pfundstein ; A. Förster ... JF - Microscopy of semiconducting materials 1995 : proceedings of the Institute of Physics Conference held at Oxford University, 20 - 23 March 1995 / Ed. by A G Cullis ... - (Conference series / Institute of Physics ; 146) Y1 - 1995 SN - 0-7503-0347-6 N1 - MSM <9, 1995, Oxford> ; Institut of Physics SP - 195 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Lauter, J. A1 - Lüth, H. T1 - AlGaAs/GaAs avalanche detector array -1 GBit/s X-ray receiver for timing measurements / J. Lauter ; A. Förster ; H. Lüth ... JF - 1995 IEEE conference record : October 21 - 28, 1995, San Francisco / Patricia A. Moonier, guest ed. - Vol. 1 Y1 - 1996 SN - 0-7803-3180-X N1 - Nuclear Science Symposium <1995, San Francisco, Calif.> ; Medical Imaging Conference <1995, San Francisco, Calif.> ; IEEE catalog number: 95CH35898 SP - 579 EP - ff. PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Lentzen, M. A1 - Gerthsen, D. T1 - Strain relaxation of lattice-mismatched In0.2Ga0.8As/GaAs superlattices on GaAs(001) substrates / M. Lentzen ; D. Gerthsen ; A. Förster ... JF - Microscopy of semiconducting materials 1995 : proceedings of the Institute of Physics Conference held at Oxford University, 20 - 23 March 1995 / Ed. by A G Cullis ... - (Conference series / Institute of Physics ; 146) Y1 - 1995 SN - 0-7503-0347-6 N1 - MSM <9, 1995, Oxford> ; Institut of Physics SP - 357 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Rose, D. A1 - Pietsch, U. A1 - Metzger, T. H. T1 - Depth resolved investigations of the relaxation behaviour in strained GaInAs/GaAs superlattices using grazing incidence X-ray diffraction / Rose, D. ; Pietsch, U. ; Förster, A. ; Metzger, T. H. JF - Nuclear instruments and methods in physics research / Section B, Beam interactions with materials and atoms. 97 (1995), H. 1-4 Y1 - 1995 SN - 0168-583X SP - 333 EP - 336 ER - TY - JOUR A1 - Förster, Arnold A1 - Rosenauer, A. A1 - Remmele, T. T1 - Strain determination in mismatched semiconductor heterostructures by the digital analysis of lattice images / A. Rosenauer ; T. Remmele ; U. Fischer ; A. Förster ... JF - Microscopy of semiconducting materials 1997 : proceedings of the Royal Microscopical Society Conference held at Oxford University, 7 - 10 April 1997 / ed. by A. G. Cullis ... - (Conference series / Institute of Physics ; 157) Y1 - 1997 SN - 0-7503-0464-2 N1 - MSM <10, 1997, Oxford> ; Conference on Microscopy of Semiconducting Materials <10, 1997, Oxford> ; Institut of Physics SP - 39 EP - ff. PB - Institute of Physics CY - Bristol [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Schmidt, T. A1 - Haug, R. J. T1 - Imaging the local density of states in a disordered semiconductor / T. Schmidt ; R. J. Haug ; V. I. Fal'ko ... A. Förster ... JF - 23rd International Conference on the Physics of Semiconductors : Berlin, Germany, July 21 - 26, 1996 / ed.: Matthias Scheffler ... - Vol. 3 Y1 - 1996 SN - 981-02-2947-X N1 - International Conference on the Physics of Semiconductors <23, 1996, Berlin> SP - 2251 EP - ff. PB - World Scientific CY - Singapore [u.a.] ER - TY - JOUR A1 - Förster, Arnold A1 - Kordos, P. A1 - Ruders, F. T1 - Properties of LT MBE GaAs for photomixing up to THz frequencies / P. Kordos ; F. Ruders ; M. Marso ; A. Förster JF - Proceedings : 8 - 11 December 1996, Australian National University, Canberra, Australia / ed.: C. Jagadish Y1 - 1997 SN - 0-7803-3374-8 N1 - Conference on Optoelectronic and Microelectronic Materials and Devices <1996, Canberra> ; IEEE catalog number: 96TH8197 SP - 71 EP - ff. PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Hu, Quing A1 - Verghese, S. T1 - High-frequency (f ~ 1 THz) studies of quantum-effect devices / Qing Hu ; S. Verghese ; R. A. Wyss ... A. Förster JF - Semiconductor science and technology. 11 (1996), H. 12 Y1 - 1996 SN - 1361-6641 SP - 1888 EP - 1894 ER - TY - JOUR A1 - Förster, Arnold A1 - Schmidt, T. A1 - Haug, R. J. T1 - Spectroscopy of local density of states fluctuations in a disordered conductor / T. Schmidt ; R. J. Haug ; V. I. Fal'ko ... A. Förster ... JF - Europhysics letters. 36 (1996), H. 1 Y1 - 1996 SN - 1286-4854 SP - 61 EP - 66 ER - TY - JOUR A1 - Förster, Arnold A1 - Tillmann, K. A1 - Thust, M. T1 - Determination of segregation, elastic strain and thin-foil relaxation in InxGa-1-x As islands on GaAs(001) by high resolution transmission electron microscopy / K. Tillmann ; A. Thust ; M. Lentzen ... A. Förster ... JF - Philosophical magazine / Letters. 74 (1996), H. 5 Y1 - 1996 SN - 1362-3036 SP - 309 EP - 315 ER - TY - JOUR A1 - Förster, Arnold A1 - Lauter, J. A1 - Lüth, H. T1 - AlGaAs/GaAs avalanche detector array-1 GBit/s X-ray receiver fortiming measurements / J. Lauter ; A. Förster ; H. Lüth ... JF - IEEE Transactions on Nuclear Science (T-NS). 43 (1996), H. 3, Part 2 Y1 - 1996 SN - 0018-9499 SP - 1446 EP - 1451 ER - TY - JOUR A1 - Förster, Arnold A1 - Lachenmann, S. G. A1 - Kastalsky, A. T1 - Novel hybrid Nb/InAs/Nb step junctions / S. G. Lachenmann ; A. Kastalsky ; I. Friedrich ; A. Förster ... JF - Czechoslovak journal of physics . 46 (1996), H. S2 Y1 - 1996 SN - 0011-4626 SP - 659 ER -