TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Capacitive field-effect eis chemical sensors and biosensors: A status report JF - Sensors N2 - Electrolyte-insulator-semiconductor (EIS) field-effect sensors belong to a new generation of electronic chips for biochemical sensing, enabling a direct electronic readout. The review gives an overview on recent advances and current trends in the research and development of chemical sensors and biosensors based on the capacitive field-effect EIS structure—the simplest field-effect device, which represents a biochemically sensitive capacitor. Fundamental concepts, physicochemical phenomena underlying the transduction mechanism and application of capacitive EIS sensors for the detection of pH, ion concentrations, and enzymatic reactions, as well as the label-free detection of charged molecules (nucleic acids, proteins, and polyelectrolytes) and nanoparticles, are presented and discussed. Y1 - 2020 U6 - http://dx.doi.org/10.3390/s20195639 SN - 1424-8220 VL - 20 IS - 19 PB - MDPI CY - Basel ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Recent progress in silicon-based biologically sensitive field-effect devices JF - Current Opinion in Electrochemistry N2 - Biologically sensitive field-effect devices (BioFEDs) advantageously combine the electronic field-effect functionality with the (bio)chemical receptor’s recognition ability for (bio)chemical sensing. In this review, basic and widely applied device concepts of silicon-based BioFEDs (ion-sensitive field-effect transistor, silicon nanowire transistor, electrolyte-insulator-semiconductor capacitor, light-addressable potentiometric sensor) are presented and recent progress (from 2019 to early 2021) is discussed. One of the main advantages of BioFEDs is the label-free sensing principle enabling to detect a large variety of biomolecules and bioparticles by their intrinsic charge. The review encompasses applications of BioFEDs for the label-free electrical detection of clinically relevant protein biomarkers, deoxyribonucleic acid molecules and viruses, enzyme-substrate reactions as well as recording of the cell acidification rate (as an indicator of cellular metabolism) and the extracellular potential. Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.coelec.2021.100811 SN - 2451-9103 IS - Article number: 100811 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Simonis, A. A1 - Lüth, H. T1 - An ISFET-based penicillin sensor with high sensitivity, low detection limit and long lifetime JF - Sensors and Actuators B. 76 (2001), H. 1-3 Y1 - 2001 SN - 0925-4005 SP - 519 EP - 526 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Thust, M. A1 - Schroth, P. A1 - Steffen, A. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Penicillin detection by means of silicon-based field-effect structures JF - Sensors and Materials. 13 (2001), H. 4 Y1 - 2001 SN - 0392-2510 SP - 207 EP - 223 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Thust, M. A1 - Schöning, Michael Josef A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Cross-sensitivity of a capacitive penicillin sensor combined with a diffusion barrier JF - Sensors and Actuators B. 68 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 260 EP - 265 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Wagner, H. A1 - Schöning, Michael Josef T1 - Automatisiertes „wafer level“-Testsystem zur Charakterisierung von siliziumbasierten Chemo- und Biosensoren JF - Sensoren und Messsysteme 2010 [Elektronische Ressource] : Vorträge der 15. ITG/GMA-Fachtagung vom 18. bis 19. Mai 2010 in Nürnberg / Informationstechnische Gesellschaft im VDE (ITG); VDI/VDE-Gesellschaft Mess- und Automatisierungstechnik (GMA) Y1 - 2010 SN - 978-3-8007-3260-9 N1 - Fachtagung Sensoren und Messsysteme 15, 2010, Nürnberg ; Gesellschaft Mess- und Automatisierungstechnik SP - 89 EP - 92 PB - VDE Verlag CY - Berlin ER - TY - JOUR A1 - Poghossian, Arshak A1 - Wagner, Holger A1 - Schöning, Michael Josef T1 - Functional testing and characterisation of (bio-)chemical sensors on wafer level JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 835 EP - 838 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Wagner, Holger A1 - Schöning, Michael Josef T1 - Functional testing and characterisation of (bio-)chemical sensors on wafer level JF - Sensors and Actuators B: Chemical. 154 (2011), H. 2 Y1 - 2011 SN - 1873-3077 N1 - EUROSENSORS XXIII SP - 169 EP - 173 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Weil, M. A1 - Cherstvy, A. G. A1 - Schöning, Michael Josef T1 - Electrical monitoring of polyelectrolyte multilayer formation by means of capacitive field-effect devices JF - Analytical and bioanalytical chemistry N2 - The semiconductor field-effect platform represents a powerful tool for detecting the adsorption and binding of charged macromolecules with direct electrical readout. In this work, a capacitive electrolyte–insulator–semiconductor (EIS) field-effect sensor consisting of an Al-p-Si-SiO2 structure has been applied for real-time in situ electrical monitoring of the layer-by-layer formation of polyelectrolyte (PE) multilayers (PEM). The PEMs were deposited directly onto the SiO2 surface without any precursor layer or drying procedures. Anionic poly(sodium 4-styrene sulfonate) and cationic weak polyelectrolyte poly(allylamine hydrochloride) have been chosen as a model system. The effect of the ionic strength of the solution, polyelectrolyte concentration, number and polarity of the PE layers on the characteristics of the PEM-modified EIS sensors have been studied by means of capacitance–voltage and constant-capacitance methods. In addition, the thickness, surface morphology, roughness and wettabilityof the PE mono- and multilayers have been characterised by ellipsometry, atomic force microscopy and water contact-angle methods, respectively. To explain potential oscillations on the gate surface and signal behaviour of the capacitive field-effect EIS sensor modified with a PEM, a simplified electrostatic model that takes into account the reduced electrostatic screening of PE charges by mobile ions within the PEM has been proposed and discussed. Y1 - 2013 U6 - http://dx.doi.org/10.1007/s00216-013-6951-9 SN - 1432-1130 ; 1618-2642 VL - 405 IS - 20 SP - 6425 EP - 6436 PB - Springer CY - Berlin ER - TY - JOUR A1 - Poghossian, Arshak A1 - Weil, M. H. A1 - Bäcker, Matthias A1 - Mayer, D. A1 - Schöning, Michael Josef T1 - Field-effect Devices Functionalised with Gold-Nanoparticle/Macromolecule Hybrids: New Opportunities for a Label-Free Biosensing JF - Procedia Engineering N2 - Field-effect capacitive electrolyte-insulator-semiconductor (EIS) sensors functionalised with citrate-capped gold nanoparticles (AuNP) have been used for the electrostatic detection of macromolecules by their intrinsic molecular charge. The EIS sensor detects the charge changes in the AuNP/macromolecule hybrids induced by the adsorption or binding events. A feasibility of the proposed detection scheme has been exemplary demonstrated by realising EIS sensors for the detection of poly-D-lysine molecules. Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.proeng.2012.09.136 SN - 1877-7058 N1 - Part of special issue "26th European Conference on Solid-State Transducers, EUROSENSOR 2012" IS - 47 SP - 273 EP - 276 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Poghossian, Arshak A1 - Weiland, Maryam A1 - Schöning, Michael Josef ED - Lvova, Larisa ED - Kirsanov, Dmitry ED - di Natale, Corrado ED - Legin, Audrey T1 - Nanoplate field-effect capacitors: a new transducer structure for multiparameter (bio-)chemical sensing T2 - Multisensor system for chemical analysis : materials and sensors N2 - An array of electrically isolated nanoplate field-effect silicon-on-insulator (SOI) capacitors as a new transducer structure for multiparameter (bio-)chemical sensing is presented. The proposed approach allows addressable biasing and electrical readout of multiple nanoplate field-effect capacitive (bio-)chemical sensors on the same SOI chip, as well as differential-mode measurements. The realized sensor chip has been applied for pH and penicillin concentration measurements, electrical monitoring of polyelectrolyte multilayer formation, and the label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization and denaturation events. Y1 - 2014 SN - 978-981-4411-15-8 ; 978-981-4411-16-5 U6 - http://dx.doi.org/10.1201/b15491-11 SP - 333 EP - 373 PB - Jenny Stanford Publishing CY - Singapore ET - 1 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Welden, Rene A1 - Buniatyan, Vahe V. A1 - Schöning, Michael Josef T1 - An Array of On-Chip Integrated, Individually Addressable Capacitive Field-Effect Sensors with Control Gate: Design and Modelling JF - Sensors N2 - The on-chip integration of multiple biochemical sensors based on field-effect electrolyte-insulator-semiconductor capacitors (EISCAP) is challenging due to technological difficulties in realization of electrically isolated EISCAPs on the same Si chip. In this work, we present a new simple design for an array of on-chip integrated, individually electrically addressable EISCAPs with an additional control gate (CG-EISCAP). The existence of the CG enables an addressable activation or deactivation of on-chip integrated individual CG-EISCAPs by simple electrical switching the CG of each sensor in various setups, and makes the new design capable for multianalyte detection without cross-talk effects between the sensors in the array. The new designed CG-EISCAP chip was modelled in so-called floating/short-circuited and floating/capacitively-coupled setups, and the corresponding electrical equivalent circuits were developed. In addition, the capacitance-voltage curves of the CG-EISCAP chip in different setups were simulated and compared with that of a single EISCAP sensor. Moreover, the sensitivity of the CG-EISCAP chip to surface potential changes induced by biochemical reactions was simulated and an impact of different parameters, such as gate voltage, insulator thickness and doping concentration in Si, on the sensitivity has been discussed. KW - equivalent circuit KW - multianalyte detection KW - control gate KW - on-chip integrated addressable EISCAP sensors KW - capacitive field-effect sensor Y1 - 2021 U6 - http://dx.doi.org/10.3390/s21186161 SN - 1424-8220 N1 - This article belongs to the Special Issue "Field-Effect Sensors: From pH Sensing to Biosensing" VL - 21 IS - 18 SP - 17 PB - MDPI CY - Basel ER - TY - JOUR A1 - Poghossian, Arshak A1 - Werner, Frederik A1 - Buniatyan, V. V. A1 - Wagner, Torsten A1 - Miamoto, K. A1 - Yoshinobu, T. A1 - Schöning, Michael Josef T1 - Towards addressability of light-addressable potentiometric sensors: Shunting effect of non-illuminated region and cross-talk JF - Sensor and Actuators B: Chemical N2 - The LAPS (light-addressable potentiometric sensor) platform is one of the most attractive approaches for chemical and biological sensing with many applications ranging from pH and ion/analyte concentration measurements up to cell metabolism detection and chemical imaging. However, although it is generally accepted that LAPS measurements are spatially resolved, the light-addressability feature of LAPS devices has not been discussed in detail so far. In this work, an extended electrical equivalent-circuit model of the LAPS has been presented, which takes into account possible cross-talk effects due to the capacitive coupling of the non-illuminated region. A shunting effect of the non-illuminated area on the measured photocurrent and addressability of LAPS devices has been studied. It has been shown, that the measured photocurrent will be determined not only by the local interfacial potential in the illuminated region but also by possible interfacial potential changes in the non-illuminated region, yielding cross-talk effects. These findings were supported by the experimental investigations of a penicillin-sensitive multi-spot LAPS and a metal-insulator-semiconductor LAPS as model systems. Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.snb.2017.01.047 SN - 0925-4005 IS - 244 SP - 1071 EP - 1079 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Yoshinobu, T. A1 - Simonis, A. A1 - Ecken, H. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS? JF - Proceedings : Copenhagen, Denmark, 27 - 30 August 2000 / [ed.: R. de Reus ...] Y1 - 2000 SN - 87-89935-50-0 N1 - Eurosensors ; (14, 2000, København) ; Eurosensors ; (14 : ; 2000.08.27-30 : ; Copenhagen) ; European Conference on Solid-State Transducers ; (14 : ; 2000.08.27-30 : ; Copenhagen) SP - 27 EP - 30 PB - MIC, Mikroelektronik Centret CY - Lyngby, Denmark ER - TY - JOUR A1 - Poghossian, Arshak A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - Flow-velocity microsensors based on semiconductor field-effect structures JF - Sensors. 3 (2003), H. 7 Y1 - 2003 SN - 1424-8220 SP - 202 EP - 212 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Yoshinobu, Tatsuo A1 - Simonis, A. A1 - Ecken, H. A1 - Lüth, Hans A1 - Schöning, Michael Josef T1 - Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS? JF - Sensors and Actuators B. 78 (2001), H. 1-3 Y1 - 2001 SN - 0925-4005 SP - 237 EP - 242 ER - TY - JOUR A1 - Reisert, Steffen A1 - Geissler, H. A1 - Florke, R. A1 - Wagner, P. A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Controlling aseptic sterilization processes by means of a multi-sensor system Y1 - 2011 N1 - 2011 IEEE Workshop on Merging Fields of Computational Intelligence and Sensor Technology ; 11.-15. April 2011 Paris, France SP - 18 EP - 22 PB - IEEE CY - New York ER - TY - JOUR A1 - Reisert, Steffen A1 - Geissler, H. A1 - Weiler, C. A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Multiple sensor-type system for monitoring the microbicidal effectiveness of aseptic sterilisation processes JF - Food control N2 - The present work describes a novel multiple sensor-type system for the real-time analysis of aseptic sterilisation processes employing gaseous hydrogen peroxide (H2O2) as a sterilant. The inactivation kinetics of Bacillus atrophaeus by gaseous H2O2 have been investigated by means of a methodical calibration experiment, taking into account the process variables H2O2 concentration, humidity and gas temperature. It has been found that the microbicidal effectiveness at H2O2 concentrations above 2% v/v is largely determined by the concentration itself, while at lower H2O2 concentrations, the gas temperature and humidity play a leading role. Furthermore, the responses of different types of gas sensors towards the influencing factors of the sterilisation process have been analysed within the same experiment. Based on a correlation established between the inactivation kinetics and the sensor responses, a calorimetric H2O2 sensor and a metal-oxide semiconductor (MOX) sensor have been identified as possible candidates for monitoring the microbicidal effectiveness of aseptic sterilisation processes employing gaseous H2O2. Therefore, two linear models that describe the relationship between sensor response and microbicidal effectiveness have been proposed. Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.foodcont.2014.07.063 SN - 1873-7129 (E-Journal); 0956-7135 (Print) VL - 47 SP - 615 EP - 622 ER - TY - JOUR A1 - Reisert, Steffen A1 - Geissler, Hanno A1 - Flörke, Rudolf A1 - Näther, Niko A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Towards a multi-sensor system for the evaluation of aseptic processes employing hydrogen peroxide vapour (H2O2) JF - Physica status solidi (a) : applications and material science. 208 (2011), H. 6 Y1 - 2011 SN - 1862-6319 SP - 1351 EP - 1356 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Reisert, Steffen A1 - Geissler, Hanno A1 - Flörke, Rudolf A1 - Weiler, Christian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Characterisation of aseptic sterilisation processes using an electronic nose JF - International journal of nanotechnology Y1 - 2013 SN - 1475-7435 (Print) 7141-8151 (Online) VL - Vol. 10 IS - No. 5-7 SP - 470 EP - 484 PB - Inderscience Enterprises CY - Genève ER - TY - JOUR A1 - Reisert, Steffen A1 - Henkel, H. A1 - Schneider, A. A1 - Schäfer, D. A1 - Friedrich, P. A1 - Berger, J. A1 - Schöning, Michael Josef T1 - Entwicklung eines Handheld-Sensorsystems für die „On-line“-Messung der H2O2-Konzentration in aseptischen Entkeimungsprozessen JF - 9. Dresdner Sensor-Symposium : Dresden, 07.-09. Dezember 2009 / Gerlach, Gerald ; Hauptmann, Peter [Hrsg.] Y1 - 2009 SN - 978-3-941298-44-6 N1 - Dresdner Sensor-Symposium ; (9, 2009, Dresden) SP - 285 EP - 288 PB - TUDpress CY - Dresden ER - TY - JOUR A1 - Reisert, Steffen A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schäfer, Daniel A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Schöning, Michael Josef T1 - Development of a handheld sensor system for the online measurement of hydrogen peroxide in aseptic filling systems JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 913 EP - 918 ER - TY - JOUR A1 - Reisert, Steffen A1 - Schneider, Benno A1 - Geissler, Hanno A1 - Gompel, Matthias van A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Multi-sensor chip for the investigation of different types of metal oxides for the detection of H2O2 in the ppm range JF - physica status solidi (a) N2 - In this work, a multi-sensor chip for the investigation of the sensing properties of different types of metal oxides towards hydrogen peroxide in the ppm range is presented. The fabrication process and physical characterization of the multi-sensor chip are described. Pure SnO2 and WO3 as well as Pd- and Pt-doped SnO2 films are characterized in terms of their sensitivity to H2O2. The sensing films have been prepared by drop-coating of water-dispensed nano-powders. A physical characterization, including scanning electron microscopy and X-ray diffraction analysis of the deposited metal-oxide films, was done. From the measurements in hydrogen peroxide atmosphere, it could be shown, that all of the tested metal oxide films are suitable for the detection of H2O2 in the ppm range. The highest sensitivity and reproducibility was achieved using Pt-doped SnO2. Calibration plot of a SnO2, WO3, Pt-, and Pd-doped SnO2 gas sensor for H2O2 concentrations in the ppm range. Y1 - 2013 SN - 1862-6319 VL - 210 IS - 5 SP - 898 EP - 904 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Riemer, A. A1 - Schroth, P. A1 - Schütz, S. A1 - Hummel, Hans E. A1 - Lüth, H. A1 - Kohl, C.-D. A1 - Schöning, Michael Josef T1 - The future of fire detection: Biological sensors? – Die Zukunft der Brandgassensorik: Biologische Sensoren? JF - Gassensorik in der Brandmeldetechnik : [VdS-Fachtagung, am 15. und 16. November 2000 in Köln] = Gas sensors for fire detection / VdS Schadenverhütung Y1 - 2000 N1 - Fachtagung Gassensorik in der Brandmeldetechnik ; (2000, Köln) SP - 1 EP - 7 PB - VdS Schadenverhütung CY - Köln ER - TY - CHAP A1 - Roderburg, Katharina A1 - Schöning, Michael Josef T1 - 1. Graduierten-Tagung : 9. September 2008 / [Hrsg.: K. Roderburg ; M. J. Schöning] T1 - 1st Graduate Symposium N2 - Tagungsband der Graduiertentagung der FH Aachen, in dem Doktorandinnen und Doktoranden und ihre Forschungsbereiche vorgestellt werden T3 - Graduiertentagung / FH Aachen - 1 KW - Aachen / Fachhochschule Aachen KW - Graduierter KW - Promotionsstudium KW - Graduiertentagung KW - Graduate symposium Y1 - 2008 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-3125 ER - TY - JOUR A1 - Rodrigues, Raul T. A1 - Morais, Paulo V. A1 - Nordi, Cristina S. F. A1 - Schöning, Michael Josef A1 - Siqueira Jr., José R. A1 - Caseli, Luciano T1 - Carbon Nanotubes and Algal Polysaccharides To Enhance the Enzymatic Properties of Urease in Lipid Langmuir-Blodgett Films JF - Langmuir N2 - Algal polysaccharides (extracellular polysaccharides) and carbon nanotubes (CNTs) were adsorbed on dioctadecyldimethylammonium bromide Langmuir monolayers to serve as a matrix for the incorporation of urease. The physicochemical properties of the supramolecular system as a monolayer at the air–water interface were investigated by surface pressure–area isotherms, surface potential–area isotherms, interfacial shear rheology, vibrational spectroscopy, and Brewster angle microscopy. The floating monolayers were transferred to hydrophilic solid supports, quartz, mica, or capacitive electrolyte–insulator–semiconductor (EIS) devices, through the Langmuir–Blodgett (LB) technique, forming mixed films, which were investigated by quartz crystal microbalance, fluorescence spectroscopy, and field emission gun scanning electron microscopy. The enzyme activity was studied with UV–vis spectroscopy, and the feasibility of the thin film as a urea sensor was essayed in an EIS sensor device. The presence of CNT in the enzyme–lipid LB film not only tuned the catalytic activity of urease but also helped to conserve its enzyme activity. Viability as a urease sensor was demonstrated with capacitance–voltage and constant capacitance measurements, exhibiting regular and distinctive output signals over all concentrations used in this work. These results are related to the synergism between the compounds on the active layer, leading to a surface morphology that allowed fast analyte diffusion owing to an adequate molecular accommodation, which also preserved the urease activity. This work demonstrates the feasibility of employing LB films composed of lipids, CNT, algal polysaccharides, and enzymes as EIS devices for biosensing applications. Y1 - 2018 U6 - http://dx.doi.org/10.1021/acs.langmuir.7b04317 SN - 1520-5827 VL - 34 IS - 9 SP - 3082 EP - 3093 PB - ACS Publications CY - Washington, DC ER - TY - JOUR A1 - Rolka, David A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Integration of a capacitive EIS sensor into a FIA system for pH and penicillin determination JF - Sensors. 4 (2004) Y1 - 2004 SN - 1424-8220 SP - 84 EP - 94 ER - TY - JOUR A1 - Röhlen, Desiree A1 - Pilas, Johanna A1 - Dahmen, Markus A1 - Keusgen, Michael A1 - Selmer, Thorsten A1 - Schöning, Michael Josef T1 - Toward a Hybrid Biosensor System for Analysis of Organic and Volatile Fatty Acids in Fermentation Processes JF - Frontiers in Chemistry N2 - Monitoring of organic acids (OA) and volatile fatty acids (VFA) is crucial for the control of anaerobic digestion. In case of unstable process conditions, an accumulation of these intermediates occurs. In the present work, two different enzyme-based biosensor arrays are combined and presented for facile electrochemical determination of several process-relevant analytes. Each biosensor utilizes a platinum sensor chip (14 × 14 mm²) with five individual working electrodes. The OA biosensor enables simultaneous measurement of ethanol, formate, d- and l-lactate, based on a bi-enzymatic detection principle. The second VFA biosensor provides an amperometric platform for quantification of acetate and propionate, mediated by oxidation of hydrogen peroxide. The cross-sensitivity of both biosensors toward potential interferents, typically present in fermentation samples, was investigated. The potential for practical application in complex media was successfully demonstrated in spiked sludge samples collected from three different biogas plants. Thereby, the results obtained by both of the biosensors were in good agreement to the applied reference measurements by photometry and gas chromatography, respectively. The proposed hybrid biosensor system was also used for long-term monitoring of a lab-scale biogas reactor (0.01 m³) for a period of 2 months. In combination with typically monitored parameters, such as gas quality, pH and FOS/TAC (volatile organic acids/total anorganic carbonate), the amperometric measurements of OA and VFA concentration could enhance the understanding of ongoing fermentation processes. Y1 - 2018 U6 - http://dx.doi.org/10.3389/fchem.2018.00284 IS - 6 PB - Frontiers CY - Lausanne ER - TY - JOUR A1 - Röhlen, Desiree A1 - Pilas, Johanna A1 - Schöning, Michael Josef A1 - Selmer, Thorsten T1 - Development of an amperometric biosensor platform for the combined determination of l-Malic, Fumaric, and l-Aspartic acid JF - Applied Biochemistry and Biotechnology N2 - Three amperometric biosensors have been developed for the detection of L-malic acid, fumaric acid, and L -aspartic acid, all based on the combination of a malate-specific dehydrogenase (MDH, EC 1.1.1.37) and diaphorase (DIA, EC 1.8.1.4). The stepwise expansion of the malate platform with the enzymes fumarate hydratase (FH, EC 4.2.1.2) and aspartate ammonia-lyase (ASPA, EC 4.3.1.1) resulted in multi-enzyme reaction cascades and, thus, augmentation of the substrate spectrum of the sensors. Electrochemical measurements were carried out in presence of the cofactor β-nicotinamide adenine dinucleotide (NAD+) and the redox mediator hexacyanoferrate (III) (HCFIII). The amperometric detection is mediated by oxidation of hexacyanoferrate (II) (HCFII) at an applied potential of + 0.3 V vs. Ag/AgCl. For each biosensor, optimum working conditions were defined by adjustment of cofactor concentrations, buffer pH, and immobilization procedure. Under these improved conditions, amperometric responses were linear up to 3.0 mM for L-malate and fumarate, respectively, with a corresponding sensitivity of 0.7 μA mM−1 (L-malate biosensor) and 0.4 μA mM−1 (fumarate biosensor). The L-aspartate detection system displayed a linear range of 1.0–10.0 mM with a sensitivity of 0.09 μA mM−1. The sensor characteristics suggest that the developed platform provides a promising method for the detection and differentiation of the three substrates. Y1 - 2017 U6 - http://dx.doi.org/10.1007/s12010-017-2578-1 SN - 1559-0291 VL - 183 SP - 566 EP - 581 PB - Springer CY - Berlin ER - TY - JOUR A1 - Schmitt, G. A1 - Faßbender, F. A1 - Lüth, H. A1 - Schöning, Michael Josef A1 - Schultze, J. W. A1 - Buß, G. T1 - Passivation and corrosion of microelectrode arrays JF - Materials and Corrosion. 51 (2000), H. 1 Y1 - 2000 SN - 0947-5117 SP - 20 EP - 25 ER - TY - JOUR A1 - Schmitt, G. A1 - Werner, C. A1 - Schöning, Michael Josef T1 - Microelectrochemical efficiency evaluation of inhibitors for CO2 corrosion of carbon steel under high shear stress gradients JF - Corrosion 2002. Conference Proceedings. NACExpo, 57th Annual Conference and Exhibition, Denver, US, Apr 7-11, 2002 Y1 - 2002 N1 - Paper 02280 SP - 1 EP - 11 PB - NACE International CY - Houston, Texas ER - TY - JOUR A1 - Scholl, Fabio A1 - Morais, Paulo A1 - Gabriel, Rayla A1 - Schöning, Michael Josef A1 - Siqueira, Jose Roberto, Jr. A1 - Caseli, Luciano T1 - Carbon nanotubes arranged as smart interfaces in lipid Langmuir-Blodgett films enhancing the enzymatic properties of penicillinase for biosensing applications JF - Applied Materials & Interfaces N2 - In this paper, carbon nanotubes (CNTs) were incorporated in penicillinase-phospholipid Langmuir and Langmuir–Blodgett (LB) films to enhance the enzyme catalytic properties. Adsorption of the penicillinase and CNTs at dimyristoylphosphatidic acid (DMPA) monolayers at the air–water interface was investigated by surface pressure–area isotherms, vibrational spectroscopy, and Brewster angle microscopy. The floating monolayers were transferred to solid supports through the LB technique, forming mixed DMPA-CNTs-PEN films, which were investigated by quartz crystal microbalance, vibrational spectroscopy, and atomic force microscopy. Enzyme activity was studied with UV–vis spectroscopy and the feasibility of the supramolecular device nanostructured as ultrathin films were essayed in a capacitive electrolyte–insulator–semiconductor (EIS) sensor device. The presence of CNTs in the enzyme–lipid LB film not only tuned the catalytic activity of penicillinase but also helped conserve its enzyme activity after weeks, showing increased values of activity. Viability as penicillin sensor was demonstrated with capacitance/voltage and constant capacitance measurements, exhibiting regular and distinctive output signals over all concentrations used in this work. These results may be related not only to the nanostructured system provided by the film, but also to the synergism between the compounds on the active layer, leading to a surface morphology that allowed a fast analyte diffusion because of an adequate molecular accommodation, which also preserved the penicillinase activity. This work therefore demonstrates the feasibility of employing LB films composed of lipids, CNTs, and enzymes as EIS devices for biosensing applications. Y1 - 2017 U6 - http://dx.doi.org/10.1021/acsami.7b08095 SN - 1944-8252 VL - 9 IS - 36 SP - 31054 EP - 31066 PB - ACS CY - Washington ER - TY - JOUR A1 - Schroth, P. A1 - Lüth, H. A1 - Hummel, Hans E. A1 - Schütz, S. A1 - Schöning, Michael Josef T1 - Characterising an insect antenna as a receptor for a biosensor by means of impedance spectroscopy JF - Scaling down in electrochemistry : electrochemical micro- and nanosystem technology ; proceedings of the 3rd International Symposium on Electrochemical Microsystem Technologies, Garmisch-Patenkirchen, Germany, 11 - 15 September 2000 / ed. by J. W. Schultz Y1 - 2001 SN - 0-08-044014-2 SP - 293 EP - 297 PB - Elsevier [u.a.] CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Schroth, P. A1 - Schöning, Michael Josef A1 - Lüth, H. A1 - Weißbecker, B. A1 - Hummel, Hans E. A1 - Schütz, S. T1 - Extending the capabilities of an antenna/chip biosensor by employing various insect species JF - Sensors and Actuators B. 78 (2001), H. 1-3 Y1 - 2001 SN - 0925-4005 SP - 1 EP - 5 ER - TY - JOUR A1 - Schroth, P. A1 - Schöning, Michael Josef A1 - Lüth, H. A1 - Weißbecker, B. A1 - Hummel, Hans E. A1 - Schütz, S. T1 - Extending the capabilities of an antenna/chip biosensor by employing various insect species JF - Proceedings : Copenhagen, Denmark, 27 - 30 August 2000 / [ed.: R. de Reus ...] Y1 - 2000 SN - 87-89935-50-0 N1 - Eurosensors ; (14, 2000, København) ; Eurosensors ; (14 : ; 2000.08.27-30 : ; Copenhagen) ; European Conference on Solid-State Transducers ; (14 : ; 2000.08.27-30 : ; Copenhagen) SP - 27 EP - 30 PB - MIC, Mikroelektronik Centret CY - Lyngby, Denmark ER - TY - JOUR A1 - Schroth, P. A1 - Schöning, Michael Josef A1 - Schütz, S. A1 - Steffen, A. A1 - Weißbecker, B. A1 - Hummel, Hans E. A1 - Kordos, P. A1 - Lüth, H. T1 - Nachweis von organischen Duftstoffen durch Biosensoren auf der Basis von Insektenantennen JF - Gesellschaft Mess- und Automatisierungstechnik: Sensoren und Meßsysteme 2000 : Tagung Ludwigsburg, 13. und 14. März 2000 / VDI/VDE-Gesellschaft Meß- und Automatisierungstechnik Y1 - 2000 SN - 3-18-091530-7 N1 - VDI-Berichte; 1530 SP - 107 EP - 114 PB - VDI-Verl. CY - Düsseldorf: ER - TY - JOUR A1 - Schroth, P. A1 - Weißbecker, B. A1 - Schütz, S. A1 - Ecken, H. A1 - Yoshinobu, T. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Bioelectronic signal processing - intact chemoreceptors coupled to field-effect devices JF - Lecture Notes of the ICB Seminars Y1 - 2002 SP - 28 EP - 42 PB - MCB CY - Warsaw ER - TY - JOUR A1 - Schroth, P. A1 - Weißbecker, B. A1 - Schütz, S. A1 - Ecken, H. A1 - Yoshinobu, T. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Bioelectronic signal processing - intact chemoreceptors coupled to field-effect devices JF - Biocybernetics and Biomedical Engineering. 21 (2001), H. 3 Y1 - 2001 SN - 0208-5216 SP - 27 EP - 42 ER - TY - JOUR A1 - Schubert, J. A1 - Schöning, Michael Josef A1 - Mourzina, Y. G. A1 - Legin, A. V. A1 - Vlasov, Y. G. A1 - Zander, W. A1 - Lüth, H. T1 - Multicomponent thin films for electrochemical sensor applications prepared by pulsed laser deposition JF - Sensors and Actuators B. 76 (2001), H. 1-3 Y1 - 2001 SN - 0925-4005 SP - 327 EP - 330 ER - TY - CHAP A1 - Schubert, Nicole A1 - Schöning, Michael Josef T1 - 3. Graduiertentagung der FH Aachen T1 - 3rd Graduate Symposium N2 - Doktoranden der FH Aachen stellen ihre wissenschaftlichen Arbeiten aus verschiedenen Fachdisziplinen vor. T3 - Graduiertentagung / FH Aachen - 3 KW - Graduiertentagung Y1 - 2010 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-3386 ER - TY - CHAP A1 - Schusser, Sebastian A1 - Bäcker, Matthias A1 - Leinhos, Marcel A1 - Krischer, M. A1 - Wenzel, L. A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Sensorkonzept zur in vitro Echtzeitmessung des Degradationsverhaltens von biodegradierbaren Biopolymeren T2 - 11. Dresdner Sensor-Symposium : 9.-11.12.2013 Y1 - 2013 SN - 978-3-9813484-5-3 SP - 174 EP - 177 ER - TY - JOUR A1 - Schusser, Sebastian A1 - Krischer, M. A1 - Molin, D. G. M. A1 - Akker, N. M. S. van den A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Sensor System for in-situ and Real-time Monitoring of Polymer (bio) degradation JF - Procedia Engineering N2 - A sensor system for investigating (bio)degradationprocesses of polymers is presented. The system utilizes semiconductor field-effect sensors and is capable of monitoring the degradation process in-situ and in real-time. The degradation of the polymer poly(d,l-lactic acid) is exemplarily monitored in solutions with different pH value, pH-buffer solution containing the model enzyme lipase from Rhizomucormiehei and cell-culture medium containing supernatants from stimulated and non-stimulated THP-1-derived macrophages mimicking activation of the immune system. Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.proeng.2015.08.815 SN - 1877-7058 N1 - Eurosensors 2015 VL - 120 SP - 948 EP - 951 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schusser, Sebastian A1 - Krischer, Maximillian A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Monitoring of the Enzymatically Catalyzed Degradation of Biodegradable Polymers by Means of Capacitive Field-Effect Sensors JF - Analytical Chemistry N2 - Designing novel or optimizing existing biodegradable polymers for biomedical applications requires numerous tests on the effect of substances on the degradation process. In the present work, polymer-modified electrolyte–insulator–semiconductor (PMEIS) sensors have been applied for monitoring an enzymatically catalyzed degradation of polymers for the first time. The thin films of biodegradable polymer poly(d,l-lactic acid) and enzyme lipase were used as a model system. During degradation, the sensors were read-out by means of impedance spectroscopy. In order to interpret the data obtained from impedance measurements, an electrical equivalent circuit model was developed. In addition, morphological investigations of the polymer surface have been performed by means of in situ atomic force microscopy. The sensor signal change, which reflects the progress of degradation, indicates an accelerated degradation in the presence of the enzyme compared to hydrolysis in neutral pH buffer media. The degradation rate increases with increasing enzyme concentration. The obtained results demonstrate the potential of PMEIS sensors as a very promising tool for in situ and real-time monitoring of degradation of polymers. Y1 - 2015 U6 - http://dx.doi.org/10.1021/acs.analchem.5b00617 SN - 1520-6882 VL - 87 IS - 13 SP - 6607 EP - 6613 PB - ACS Publications CY - Washington, DC ER - TY - JOUR A1 - Schusser, Sebastian A1 - Leinhos, Marcel A1 - Bäcker, Matthias A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Impedance spectroscopy: A tool for real-time in situ monitoring of the degradation of biopolymers JF - Physica Status Solidi (A) N2 - Investigation of the degradation kinetics of biodegradable polymers is essential for the development of implantable biomedical devices with predicted biodegradability. In this work, an impedimetric sensor has been applied for real-time and in situ monitoring of degradation processes of biopolymers. The sensor consists of two platinum thin-film electrodes covered by a polymer film to be studied. The benchmark biomedical polymer poly(D,L-lactic acid) (PDLLA) was used as a model system. PDLLA films were deposited on the sensor structure from a polymer solution by using the spin-coating method. The degradation kinetics of PDLLA films have been studied in alkaline solutions of pH 9 and 12 by means of an impedance spectroscopy (IS) method. Any changes in a polymer capacitance/resistance induced by water uptake and/or polymer degradation will modulate the global impedance of the polymer-covered sensor that can be used as an indicator of the polymer degradation. The degradation rate can be evaluated from the time-dependent impedance spectra. As expected, a faster degradation has been observed for PDLLA films exposed to pH 12 solution. Y1 - 2013 U6 - http://dx.doi.org/10.1002/pssa.201200941 SN - 1521-396X ; 0031-8965 VL - 210 IS - 5 SP - 905 EP - 910 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Schusser, Sebastian A1 - Menzel, S. A1 - Bäcker, Matthias A1 - Leinhos, Marcel A1 - Poghossian, Arshak A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Degradation of thin poly(lactic acid) films: characterization by capacitance-voltage, atomic force microscopy, scanning electron microscopy and contact-angle measurements JF - Electrochimica Acta Y1 - 2013 SN - 1873-3859 (E-Journal); 0013-4686 (Print) VL - Vol. 113 SP - 779 EP - 784 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schusser, Sebastian A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Krischer, M. A1 - Leinhos, Marcel A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - An application of field-effect sensors for in-situ monitoring of degradation of biopolymers JF - Sensors and actuators B: Chemical N2 - The characterization of the degradation kinetics of biodegradable polymers is mandatory with regard to their proper application. In the present work, polymer-modified electrolyte–insulator–semiconductor (PMEIS) field-effect sensors have been applied for in-situ monitoring of the pH-dependent degradation kinetics of the commercially available biopolymer poly(d,l-lactic acid) (PDLLA) in buffer solutions from pH 3 to pH 13. PDLLA films of 500 nm thickness were deposited on the surface of an Al–p-Si–SiO2–Ta2O5 structure from a polymer solution by means of spin-coating method. The PMEIS sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. A faster degradation has been observed for PDLLA films exposed to alkaline solutions (pH 9, pH 11 and pH 13). Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.snb.2014.10.058 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - 207, Part B SP - 954 EP - 959 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schusser, Sebastian A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Leinhos, Marcel A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Characterization of biodegradable polymers with capacitive field-effect sensors JF - Sensors and actuators B: Chemical N2 - In vitro studies of the degradation kinetic of biopolymers are essential for the design and optimization of implantable biomedical devices. In the presented work, a field-effect capacitive sensor has been applied for the real-time and in situ monitoring of degradation processes of biopolymers for the first time. The polymer-covered field-effect sensor is, in principle, capable to detect any changes in bulk, surface and interface properties of the polymer induced by degradation processes. The feasibility of this approach has been experimentally proven by using the commercially available biomedical polymer poly(D,L-lactic acid) (PDLLA) as a model system. PDLLA films of different thicknesses were deposited on the Ta₂O₅-gate surface of the field-effect structure from a polymer solution by means of spin-coating method. The polymer-modified field-effect sensors have been characterized by means of capacitance–voltage and impedance-spectroscopy method. The degradation of the PDLLA was accelerated by changing the degradation medium from neutral (pH 7.2) to alkaline (pH 9) condition, resulting in drastic changes in the capacitance and impedance spectra of the polymer-modified field-effect sensor. KW - Impedance spectroscopy KW - C–V method KW - Real-time monitoring KW - Poly(d,l-lacticacid) KW - (Bio)degradation KW - Field-effect sensor Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.snb.2012.07.099 SN - 0925-4005 N1 - Part of special issue "Selected Papers from the 14th International Meeting on Chemical Sensors" VL - 187 SP - 2 EP - 7 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Schusser, Sebastian A1 - Vaeßen, Christiane A1 - Schöning, Michael Josef T1 - 4. Graduiertentagung der FH Aachen 24. November 2011 T1 - 4th Graduate Symposium FH Aachen - University of Applied Sciences November 24th, 2011 N2 - Tagungsband der 4. Graduiertentagung der FH Aachen am 24. November 2011 Proceedings from the 4th Graduate Symposium, FH Aachen, Germany, November 24th, 2011 Aachen, November 2011. 62 Seiten N2 - Proceedings from the 4th Graduate Symposium, FH Aachen, Germany, November 24th, 2011 T3 - Graduiertentagung / FH Aachen - 4 KW - Graduiertentagung Y1 - 2011 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-3530 ER - TY - CHAP A1 - Schusser, Sebastian A1 - Vaeßen, Christiane A1 - Schöning, Michael Josef T1 - 5. Graduiertentagung der FH Aachen 15. November 2012 T1 - 5th Graduate Symposium FH Aachen - University of Applied Sciences November 15th, 2012 N2 - Tagungsband der 5. Graduiertentagung der FH Aachen am 15. November 2012 N2 - Proceedings from the 5th Graduate Symposium, FH Aachen, Germany, November 15th, 2012 T3 - Graduiertentagung / FH Aachen - 5 KW - Graduiertentagung Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-50425 ER - TY - JOUR A1 - Schöning, Michael Josef T1 - Silicon-based biochemical sensors JF - CNI - The Center of Nanoelectronic Systems for Information Technology Y1 - 2003 SP - 165 EP - 170 PB - Foschungszentrum Jülich ER - TY - JOUR A1 - Schöning, Michael Josef T1 - "Playing around“ with field-effect sensors on the basis of EIS structures, LAPS and ISFETs JF - Sensors. 5 (2005), H. 3 Y1 - 2005 SN - 1424-8220 SP - 126 EP - 138 ER - TY - JOUR A1 - Schöning, Michael Josef T1 - "Voltohmmetry" – a new transducer principle for electrochemical sensors JF - Ultrathin electrochemical chemo- and biosensors : technology and performance / Vladimir M. Mirsky Y1 - 2004 SN - 3-540-21285-X SP - 117 EP - 140 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Schöning, Michael Josef T1 - Microelectronics contacts (bio-)chemistry – Semiconductor-based sensors JF - Biologi Italiani. 8 (2001) Y1 - 2001 SN - 0392-2510 SP - 5 EP - 10 ER - TY - JOUR A1 - Schöning, Michael Josef T1 - Silicon-based field-effect structures – From dielectrics to bioelectronics JF - Dielectrics in emerging technologies : proceedings of the international symposium ; [papers presented at the First International Symposium on Science and Technology of Dielectrics in Emerging Fields held from 27th April to 2nd May 2003 in Paris, France] / sponsoring divisions: Dielectric Science and Technology, Electronics. Ed.: D. Misra. Y1 - 2003 SN - 1-56677-346-6 N1 - International Symposium on Science and Technology of Dielectrics in Emerging Fields ; (1, 2003, Paris) SP - 31 EP - 37 PB - Electrochemical Society CY - Pennington, NJ ER - TY - JOUR A1 - Schöning, Michael Josef T1 - Silicon recognizes biochemical parameters: Microchips for analytical sensor applications JF - American Laboratory. 32 (2000), H. 16 Y1 - 2000 SN - 0044-7749 SP - 24 EP - 31 ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Abdelghani, Adnane T1 - Nanoscale Science and Technology (NS&T’12) : Proceedings Book Humboldt Kolleg <2012, Tunisia> ; Tunisia, 17-19 March, 2012 / ed. by Michael J. Schöning ; Adnane Abdelghani N2 - Proceedings of the 2nd Humboldt Kolleg, Hammamet, Tunisia Organizer: Alexander von Humboldt Stiftung, Germany. pdf 184 p. Welcome Address Dear Participants, Welcome to the 2nd Humboldt Kolleg in “Nanoscale Science and Technology” (NS&T’12) in Tunisia, sponsored by the "Alexander von Humboldt" foundation. The NS&T’12 multidisciplinary scientific program includes seven "hot" topics dealing with "Nanoscale Science and Technology" covering basic and application-oriented research as well as industrial (market) aspects: - Molecular Biophyics, Spectroscopy Techniques, Imaging Microscopy - Nanomaterials Synthesis for Medicine and Bio-chemical Sensors - Nanostructures, Semiconductors, Photonics and Nanodevices - New Technologies in Market Industry - Environment, Electro-chemistry, Bio-polymers and Fuel Cells - Nanomaterials, Photovoltaic, Modelling, Quantum Physics - Microelectronics, Sensors Networks and Embedded Systems We are deeply indebted to all members of the Scientific Committee and General Chairs for joint Sessions and to all speakers and chairmen, who have dedicated invaluable time and efforts for the realization of this event. On behalf of the Organizing Committee, we are cordially inviting you to join the conference and hope that your stay will be fruitful, rewarding and enjoyable. Prof. Dr. Michael J. Schöning, Prof. Dr. Adnane Abdelghani KW - Biosensor KW - Nanotechnologie KW - Nanomaterial KW - Nano Materials KW - Bio-Sensors Y1 - 2012 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-3544 ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Han, Y. A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Poghossian, Arshak T1 - Markierungsfreie DNA-Detektion mit Silizium-Feldeffektsensoren – Messeffekte oder Artefakte? T2 - Sensoren und Mess-Systeme 2006 : Vorträge der 13. ITG/GMA-Fachtagung vom 13. bis 14.3.2006 in Freiburg/Breisgau Y1 - 2006 SN - 3-8007-2939-3 SP - 443 EP - 446 PB - VDE Verl. CY - Berlin ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Ingebrandt, Sven A1 - Platen, Johannes A1 - Offenhäusser, Andreas A1 - Poghossian, Arshak ED - Comini, Elisabetta T1 - Towards label-free detection of charged macromolecules using field-effect-based structures : Scaling down from capacitive EIS sensor over ISFET to nano-scale devices JF - Nanostructured materials and hybrid composites for gas sensors and biomedical applications : symposium held April 18-20, 2006, San Francisco , California, U.S.A. Y1 - 2006 SN - 9781558998711 IS - paper 0915-R05-04 SP - 89 EP - 94 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak T1 - pH and ion sensitivity of a field-effect EIS (electrolyte-insulator-semiconductor) sensor covered with polyelectrolyte multilayers JF - Journal of Solid State Electrochemistry. 13 (2009), H. 1 Y1 - 2009 SN - 1433-0768 N1 - This manuscript is an invited paper to the special issue on “Solid-state potentiometric sensors” (Guest editor: Johan Bobacka). SP - 115 EP - 122 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Han, Yinhua A1 - Offenhäusser, Andreas A1 - Ingebrandt, Sven T1 - Markierungsfreie DNA-Detektion mit Silizium-Feldeffekt-Sensoren – Messeffekte oder Artefakte? JF - tm - Technisches Messen . 74 (2007), H. 9 Y1 - 2007 SN - 0171-8096 SP - 466 EP - 476 ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Abouzar, Maryam H. A1 - Wagner, Torsten A1 - Näther, Niko A1 - Rolka, David A1 - Yoshinobu, Tatsuo A1 - Kloock, Joachim P. A1 - Turek, Monika A1 - Ingebrandt, Sven A1 - Poghossian, Arshak T1 - A semiconductor-based field-effect platform for (bio-)chemical and physical sensors: From capacitive EIS sensors and LAPS over ISFETs to nano-scale devices T2 - MRS Proceedings Y1 - 2006 U6 - http://dx.doi.org/10.1557/PROC-0952-F08-02 N1 - Vol. 952 - Symposium F - Integrated Nanosensors SP - 1 EP - 9 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Arzdorf, M. A1 - Mulchandani, P. A1 - Chen, W. A1 - Mulchandani, A. T1 - Towards a capacitive enzyme sensor for direct determination of organophosphorus pesticides: Fundamentals studies and aspects of development JF - Sensors. 3 (2003), H. 6 Y1 - 2003 SN - 1424-8220 SP - 119 EP - 127 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Arzdorf, M. A1 - Mulchandani, P. A1 - Chen, W. A1 - Mulchandani, A. T1 - A capacitive field-effect sensor for the direct determination of organophosphorus pesticides JF - Sensors and Actuators B. 91 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 92 EP - 97 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Biselli, Manfred A1 - Selmer, Thorsten A1 - Öhlschläger, Peter A1 - Baumann, Marcus A1 - Förster, Arnold A1 - Poghossian, Arshak T1 - Forschung „zwischen“ den Disziplinen: das Institut für Nano- und Biotechnologien JF - Analytik news : das Online-Labormagazin für Labor und Analytik N2 - "Biologie trifft Mikroelektronik", das Motto des Instituts für Nano- und Biotechnologien (INB) an der FH Aachen, unterstreicht die zunehmende Bedeutung interdisziplinär geprägter Forschungsaktivitäten. Der thematische Zusammenschluss grundständiger Disziplinen, wie die Physik, Elektrotechnik, Chemie, Biologie sowie die Materialwissenschaften, lässt neue Forschungsgebiete entstehen, ein herausragendes Beispiel hierfür ist die Nanotechnologie: Hier werden neue Werkstoffe und Materialien entwickelt, einzelne Nanopartikel oder Moleküle und deren Wechselwirkung untersucht oder Schichtstrukturen im Nanometerbereich aufgebaut, die neue und vorher nicht bekannte Eigenschaften hervorbringen. Vor diesem Hintergrund bündelt das im Jahre 2006 gegründete INB die an der FH Aachen vorhandenen Kompetenzen von derzeit insgesamt sieben Laboratorien auf den Gebieten der Halbleitertechnik und Nanoelektronik, Nanostrukturen und DNA-Sensorik, der Chemo- und Biosensorik, der Enzymtechnologie, der Mikrobiologie und Pflanzenbiotechnologie, der Zellkulturtechnik, sowie der Roten Biotechnologie synergetisch. In der Nano- und Biotechnologie steckt außergewöhnliches Potenzial! Nicht zuletzt deshalb stellen sich die Forscher der Herausforderung, in diesem Bereich gemeinsam zu forschen und Schnittstellen zu nutzen, um so bei der Gestaltung neuartiger Ideen und Produkte mitzuwirken, die zukünftig unser alltägliches Leben verändern werden. Im Folgenden werden die verschiedenen Forschungsbereiche kurz zusammenfassend vorgestellt und vorhandene Interaktionen anhand von exemplarisch ausgewählten, aktuellen Forschungsprojekten skizziert. Y1 - 2012 VL - Publ. online PB - Dr. Beyer Internet-Beratung CY - Ober-Ramstadt ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Brinkmann, D. A1 - Demuth, C. A1 - Poghossian, Arshak T1 - CIP (cleaning-in-place)-suitable „non-glass“ pH sensor based on a Ta2O5-gate EIS structure JF - Digest of technical papers : September 12 - 15, 2004, Rome, Italy, Pontificia Universitas Sancto Thoma Aquinate in Urbe / [conference chairperson: C. Di Natale]. Y1 - 2004 SN - 88-7621-282-5 N1 - Eurosensors ; (18, 2004, Roma) SP - 857 EP - 860 CY - Roma ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Brinkmann, D. A1 - Rolka, David A1 - Demuth, C. A1 - Poghossian, Arshak T1 - CIP (cleaning-in-place) suitable “non-glass” pH sensor based on a Ta2O5-gate EIS structure JF - Sensors and Actuators B: Chemical. 111-112 (2005) Y1 - 2005 SN - 0925-4005 N1 - Eurosensors XVIII 2004 - The 18th European Conference on Solid-State Transducers SP - 423 EP - 429 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Bronder, Thomas A1 - Wu, Chunsheng A1 - Scheja, Sabrina A1 - Jessing, Max A1 - Metzger-Boddien, Christoph A1 - Keusgen, Michael A1 - Poghossian, Arshak T1 - Label-Free DNA Detection with Capacitive Field-Effect Devices—Challenges and Opportunities JF - Proceedings N2 - Field-effect EIS (electrolyte-insulator-semiconductor) sensors modified with a positively charged weak polyelectrolyte layer have been applied for the electrical detection of DNA (deoxyribonucleic acid) immobilization and hybridization by the intrinsic molecular charge. The EIS sensors are able to detect the existence of target DNA amplicons in PCR (polymerase chain reaction) samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process. Due to their miniaturized setup, compatibility with advanced micro- and nanotechnologies, and ability to detect biomolecules by their intrinsic molecular charge, those sensors can serve as possible platform for the development of label-free DNA chips. Possible application fields as well as challenges and limitations will be discussed. Y1 - 2017 U6 - http://dx.doi.org/10.3390/proceedings1080719 SN - 2504-3900 N1 - This article belongs to the Proceedings of "Proceedings of the 5th International Symposium on Sensor Science (I3S 2017)" VL - 1 IS - 8 SP - Artikel 719 PB - MDPI CY - Basel ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Buß, G. A1 - Faßbender, F. A1 - Glück, O. A1 - Schmitt, G. A1 - Schultze, J. W. A1 - Lüth, H. T1 - A silicon-based microelectrode array for chemical analysis JF - Sensors and Actuators B. 65 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 284 EP - 287 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Bäcker, Matthias T1 - Chip-basierte Sensoren für die Biotechnik Y1 - 2012 SN - 1611-0854 N1 - 4 Seiten VL - 13 IS - 2 PB - BIOCOM CY - Berlin ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Hüllenkremer, B. A1 - Glück, O. A1 - Lüth, H. A1 - Emons, H. T1 - Voltohmmetry – a novel sensing principle for heavy metal determination in aqueous solutions JF - Sensors and Actuators B. 78 (2001), H. 1-3 Y1 - 2001 SN - 0925-4005 SP - 275 EP - 280 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Jacobs, M. A1 - Muck, A. A1 - Knobbe, D.-T. A1 - Wang, J. A1 - Chatrathi, M. A1 - Spillmann, S. T1 - Amperometric PDMS/glass capillary electrophoresis-based biosensor microchip for catechol and dopamin detection JF - Sensors and Actuators B. 108 (2005), H. 1-2 Y1 - 2005 SN - 0925-4005 N1 - Proceedings of the Tenth International Meeting on Chemical Sensors — IMCS - 10 2004 SP - 688 EP - 694 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Jünger, M. A1 - Keusgen, M. T1 - Knoblauchgehaltsbestimmungen mit einem feldeffektbasierten Halbleiterbiosensor JF - Sensoren und Messsysteme 2004 : Tagung Ludwigsburg, 15. und 16. März 2004 / VDI-VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2004 SN - 3-18-091829-2 N1 - Auch erschienen als: VDI-Berichte ; 1829 SP - 707 EP - 714 PB - VDI CY - Düsseldorf ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kirchner, Patrick A1 - Ng, Yue Ann A1 - Spelthahn, Heiko A1 - Schneider, Andreas A1 - Henkel, Hartmut A1 - Friedrich, Peter A1 - Kolstad, Jens A1 - Berger, Jörg A1 - Keusgen, Michael T1 - Gas sensor investigation based on a catalytically activated thin-film thermopile for H2O2 detection JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 787 EP - 792 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kloock, Joachim P. T1 - About 20 years of silicon-based thin-film sensors with chalcogenide glass materials for heavy metal analysis: Technological aspects of fabrication and miniaturization JF - Electroanalysis. 19 (2007), H. 19-20 Y1 - 2007 SN - 1040-0397 SP - 2029 EP - 2038 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kloock, Joachim P. A1 - Knobbe, D.-T. A1 - Krause, R. A1 - Block, K. A1 - Wang, J. A1 - Mulchandani, A. A1 - Keusgen, M. T1 - Direktnachweis von Pestiziden und Cyanid mit elektrochemischen Enzymsensoren JF - Sensoren und Messsysteme 2004 : Tagung Ludwigsburg, 15. und 16. März 2004 / VDI-VDE-Gesellschaft Mess- und Automatisierungstechnik Y1 - 2004 SN - 3-18-091829-2 N1 - Auch erschienen als: VDI-Berichte ; 1829 SP - 699 EP - 706 PB - VDI CY - Düsseldorf ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kloock, Joachim P. A1 - Knobbe, D.-T. A1 - Räde, J. A1 - Keusgen, M. T1 - Silicon field-effect biosensor for cyanide detection JF - Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors Y1 - 2004 N1 - Chemical sensors ; 20.2004 Suppl. B. IMCS ; (10, 2004, Tsukuba) ; International Meeting on Chemical Sensors ; (10 : ; 2004.07.11-14 : ; Tsukuba) SP - 98 EP - 99 PB - Japan Association of Chemical Sensors CY - Fukuoka ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Krause, R. A1 - Block, K. A1 - Musahmeh, M. A1 - Mulchandani, A. A1 - Wang, J. T1 - A dual amperometric/potentiometric FIA-based biosensor for the distinctive detection of organophosphorus pesticides JF - Sensors and Actuators B. 95 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 291 EP - 296 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Krause, R. A1 - Block, K. A1 - Musameh, M. A1 - Mulchandani, A. A1 - Wang, J. T1 - A dual amperometric / potentiometric FIA-based biosensor for the distinctive detection of organophosphorus pesticides JF - Book of abstracts / ed. by J. Saneistr. Y1 - 2002 SN - 80-01-02576-4 N1 - Eurosensors ; (16, 2002, Praha) SP - 76 EP - 79 PB - Czech Technical University, Faculty of Electrical Engineering, Department of Measurement CY - Prague ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Kurowski, A. A1 - Thust, M. A1 - Kordos, P. A1 - Schultze, J. W. A1 - Lüth, H. T1 - Capacitive microsensors for biochemical sensing on porous silicon technology JF - Sensors and Actuators B. 64 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 59 EP - 64 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Lüth, H. T1 - Novel concepts for silicon-based biosensors JF - Physica Status Solidi (A) (2001) Y1 - 2001 SN - 0031-8965 SP - 65 EP - 77 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Malkoc, Ü. A1 - Thust, M. A1 - Steffen, A. A1 - Kordos, P. A1 - Lüth, H. T1 - Novel electrochemical sensors with structured and porous semiconductor/insulator capacitors JF - Sensors and Actuators B. 65 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 288 EP - 290 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Mourzina, Y. G. A1 - Schubert, J. A1 - Zander, W. A1 - Legin, A. A1 - Vlasov, Y. G. A1 - Lüth, H. T1 - Can pulsed laser deposition serve as an advanced technique in fabricating chemical sensors? JF - Sensors and Actuators B. 78 (2001), H. 1-3 Y1 - 2001 SN - 0925-4005 N1 - Selected Papers form Eurosensors XIV SP - 273 EP - 278 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Mourzina, Y. G. A1 - Schubert, J. A1 - Zander, W. A1 - Legin, A. A1 - Vlasov, Y. G. A1 - Lüth, H. T1 - Can pulsed laser deposition serve as an advanced technique in fabricating chemical sensors? JF - Proceedings : Copenhagen, Denmark, 27 - 30 August 2000 / [ed.: R. de Reus ...] Y1 - 2000 SN - 87-89935-50-0 N1 - Eurosensors ; (14, 2000, København) ; Eurosensors ; (14 : ; 2000.08.27-30 : ; Copenhagen) ; European Conference on Solid-State Transducers ; (14 : ; 2000.08.27-30 : ; Copenhagen) SP - 615 EP - 618 PB - MIC, Mikroelektronik Centret CY - Lyngby, Denmark ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Mourzina, Yu.G. A1 - Schubert, J. A1 - Zander, W. A1 - Legin, A. A1 - Vlasov, Y. G. A1 - Lüth, H. T1 - Pulsed laser deposition – an innovative technique for preparing inorganic thin films JF - Electroanalysis. 13 (2001), H. 8-9 Y1 - 2001 SN - 1040-0397 SP - 727 EP - 732 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Näther, Niko A1 - Auger, V. A1 - Poghossian, Arshak A1 - Koudelka-Hep, M. T1 - Miniaturised flow-through cell with integrated capacitive EIS sensor fabricated at wafer level using Si and SU-8 technologies JF - Sensors and Actuators B. 108 (2005), H. 1-2 Y1 - 2005 SN - 0925-4005 N1 - Proceedings of the Tenth International Meeting on Chemical Sensors — IMCS - 10 2004 SP - 986 EP - 992 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Näther, Niko A1 - Auger, V. A1 - Poghossian, Arshak A1 - Koudelka-Hep, M. T1 - Miniaturized flow-through cell with integrated capacitive EIS sensors fabricated at wafer level using Si and Su-8 technologies JF - Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors Y1 - 2004 N1 - Chemical sensors ; 20.2004 Suppl. B. IMCS ; (10, 2004, Tsukuba) ; International Meeting on Chemical Sensors ; (10 : ; 2004.07.11-14 : ; Tsukuba) SP - 554 EP - 555 PB - Japan Association of Chemical Sensors CY - Fukuoka ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Detection of charged macromolecules by means of field-effect devices (FEDs): possibilities and limitations JF - Electrochemical sensors, biosensors and their biomedical applications / ed. by Xueji Zhang ... Y1 - 2008 SN - 978-0-12-373738-0 SP - 187 EP - 212 PB - Elsevier Acad. Press CY - Amsterdam ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Silicon-based field-effect devices for (bio-)chemical sensing JF - International Conference on Advanced Semiconductor Devices and Microsystems, 2008. ASDAM 2008 Y1 - 2008 SN - 978-1-4244-2325-5 SP - 31 EP - 38 CY - Smolenice, Slovakia ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Silicon-based field-effect devices with nanostructured surfaces for bio-/chemical sensing JF - Semiconductor micro- and nanoelectronics : Proceedings of the Seventh International Conference , Tsakhcadzor, Armenia July 3-5 2009 Y1 - 2009 SP - 51 EP - 53 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - BioFEDs (field-effect devices) : State-of-the-art and new directions JF - Electroanalysis Y1 - 2006 U6 - http://dx.doi.org/10.1002/elan.200603609 SN - 1521-4109 VL - 18 IS - 19-20 SP - 1893 EP - 1900 ER - TY - BOOK A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Label-free biosensing: advanced materials, devices and applications Y1 - 2018 SN - 978-3-319-75219-8 PB - Springer CY - Cham ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Enzyme und Biosensorik T2 - Einführung in die Enzymtechnologie N2 - Enzymbasierte Biosensoren finden seit mehr als fünf Jahrzehnten einen prosperierenden Wachstumsmarkt und werden zunehmend auch in biotechnologischen Prozessen eingesetzt. In diesem Kapitel werden, ausgehend vom Sensorbegriff und typischen Kenngrößen für Biosensoren (Abschn. 18.1), elektrochemische Enzym-Biosensoren vorgestellt und deren typischen Einsatzgebiete diskutiert (Abschn. 18.2). Ein Blick über den „Tellerrand“ hinaus zeigt alternative Transduktorprinzipien (Abschn. 18.3) und führt abschließend in aktuelle Forschungstrends ein (Abschn. 18.4). Y1 - 2018 SN - 978-3-662-57619-9 U6 - http://dx.doi.org/10.1007/978-3-662-57619-9_18 SP - 323 EP - 347 PB - Springer Spektrum CY - Berlin ER - TY - CHAP A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Glück, Olaf A1 - Thust, Marion T1 - Electrochemical methods for the determination of chemical variables in aqueous media T2 - Measurement, instrumentation, and sensors handbook / ed. by John G. Webster [u.a.] Vol. 2 : Electromagnetic, optical, radiation, chemical, and biomedical measurement Y1 - 2014 SN - 978-1-4398-4891-3 SP - 55-1 EP - 55-54 PB - CRC Pr. CY - Boca Raton, Fla. ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Schultze, Joachim W. T1 - Measuring seven parameters by two ISFET modules in a microcell set-up JF - Int. Journal of Computational Engineering Science. 4 (2003), H. 2 Y1 - 2003 SN - 1465-8763 SP - 257 EP - 260 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak A1 - Yoshinobu, Tatsuo A1 - Lüth, Hans T1 - Semiconductor-based field-effect structures for chemical sensing Y1 - 2001 SP - 188 EP - 198 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schmidt, C. A1 - Schubert, J. A1 - Zander, W. A1 - Mesters, S. A1 - Kordos, P. A1 - Lüth, H. A1 - Legin, A. A1 - Seleznev, B. A1 - Vlasov, Y. G. T1 - Thin film sensors on the basis of chalcogenide glass materials prepared by pulsed laser deposition technique JF - Sensors and Actuators B. 68 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 254 EP - 259 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Hummel, Hans E. A1 - Weißbecker, B. A1 - Lüth, H. A1 - Schütz, S. T1 - Microcsaled living bioelectronic systems – Coupling beetles to silicon transducers JF - Chemical and biological sensors and analytical methods : proceedings of the international symposium / Sensor, Physical Electrochemistry, and Organic and Biological Electrochemistry Divisions. Ed.: M. Butler Y1 - 2001 SN - 1-56677-351-2 N1 - International Symposium: Chemical and Biological Sensors and Analytical Methods ; (2 : 2001.) SP - 165 EP - 173 PB - Electrochemical Society CY - Pennington, NJ ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Schütz, S. T1 - The use of insect chemoreceptors for the assembly of biosensors based on semiconductor field-effect sensors JF - Electroanalysis. 12 (2000), H. 9 Y1 - 2000 SN - 1040-0397 SP - 645 EP - 652 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Schütz, S. A1 - Hummel, Hans E. A1 - Lüth, H. T1 - Connecting an insect antenna to a microchip as a novel type of biosensor JF - Proceedings : applications, trends, visions / VDE World Microtechnologies Congress, September 25 - 27, 2000, Expo 2000, Hannover, Germany. Organized by VDE Association for Electrical, Electronic & Information Technologies ....Vol 2. Y1 - 2000 SN - 3-8007-2579-7 N1 - MICRO.tec <1, 2000, Hannover>; auch als CD-ROM SP - 411 EP - 416 PB - VDE-Verl. CY - [Berlin] [u.a.] ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schroth, Peter A1 - Lüth, Hans A1 - Hummel, Hans E. A1 - Schütz, Stefan T1 - Insect chemoreceptors coupled to silicon transistors as innovative biosensors JF - Proceedings of SPIE. 4205 (2001) Y1 - 2001 SP - 152 EP - 162 ER -