TY - JOUR A1 - Reisert, Steffen A1 - Geissler, H. A1 - Weiler, C. A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Multiple sensor-type system for monitoring the microbicidal effectiveness of aseptic sterilisation processes JF - Food control N2 - The present work describes a novel multiple sensor-type system for the real-time analysis of aseptic sterilisation processes employing gaseous hydrogen peroxide (H2O2) as a sterilant. The inactivation kinetics of Bacillus atrophaeus by gaseous H2O2 have been investigated by means of a methodical calibration experiment, taking into account the process variables H2O2 concentration, humidity and gas temperature. It has been found that the microbicidal effectiveness at H2O2 concentrations above 2% v/v is largely determined by the concentration itself, while at lower H2O2 concentrations, the gas temperature and humidity play a leading role. Furthermore, the responses of different types of gas sensors towards the influencing factors of the sterilisation process have been analysed within the same experiment. Based on a correlation established between the inactivation kinetics and the sensor responses, a calorimetric H2O2 sensor and a metal-oxide semiconductor (MOX) sensor have been identified as possible candidates for monitoring the microbicidal effectiveness of aseptic sterilisation processes employing gaseous H2O2. Therefore, two linear models that describe the relationship between sensor response and microbicidal effectiveness have been proposed. Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.foodcont.2014.07.063 SN - 1873-7129 (E-Journal); 0956-7135 (Print) VL - 47 SP - 615 EP - 622 ER - TY - CHAP A1 - Reisert, Steffen A1 - Geissler, H. A1 - Flörke, R. A1 - Weiler, C. A1 - Wagner, P. A1 - Schöning, Michael Josef ED - Abdelghani, Adnane ED - Schöning, Michael Josef T1 - Characterisation of aseptic sterilisation processes using an electronic nose T2 - Nanoscale Science and Technology (NS&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012 Y1 - 2012 SP - 45 EP - 45 ER - TY - JOUR A1 - Reisert, Steffen A1 - Geissler, H. A1 - Florke, R. A1 - Wagner, P. A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Controlling aseptic sterilization processes by means of a multi-sensor system Y1 - 2011 N1 - 2011 IEEE Workshop on Merging Fields of Computational Intelligence and Sensor Technology ; 11.-15. April 2011 Paris, France SP - 18 EP - 22 PB - IEEE CY - New York ER - TY - JOUR A1 - Rausch, Valentin A1 - Kahmann, Stephanie Lucina A1 - Baltschun, Christoph A1 - Staat, Manfred A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Pressure distribution to the distal biceps tendon at the radial tuberosity: a biomechanical study JF - The Journal of Hand Surgery N2 - Purpose Mechanical impingement at the narrow radioulnar space of the tuberosity is believed to be an etiological factor in the injury of the distal biceps tendon. The aim of the study was to compare the pressure distribution at the proximal radioulnar space between 2 fixation techniques and the intact state. Methods Six right arms and 6 left arms from 5 female and 6 male frozen specimens were used for this study. A pressure transducer was introduced at the height of the radial tuberosity with the intact distal biceps tendon and after 2 fixation methods: the suture-anchor and the cortical button technique. The force (N), maximum pressure (kPa) applied to the radial tuberosity, and the contact area (mm²) of the radial tuberosity with the ulna were measured and differences from the intact tendon were detected from 60° supination to 60° pronation in 15° increments with the elbow in full extension and in 45° and 90° flexion of the elbow. Results With the distal biceps tendon intact, the pressures during pronation were similar regardless of extension and flexion and were the highest at 60° pronation with 90° elbow flexion (23.3 ± 53.5 kPa). After repair of the tendon, the mean peak pressure, contact area, and total force showed an increase regardless of the fixation technique. Highest peak pressures were found using the cortical button technique at 45° flexion of the elbow and 60° pronation. These differences were significantly different from the intact tendon. The contact area was significantly larger in full extension and 15°, 30°, and 60° pronation using the cortical button technique. Conclusions Pressures on the distal biceps tendon at the radial tuberosity increase during pronation, especially after repair of the tendon. Clinical relevance Mechanical impingement could play a role in both the etiology of primary distal biceps tendon ruptures and the complications occurring after fixation of the tendon using certain techniques. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jhsa.2020.01.006 SN - 0363-5023 VL - 45 IS - 8 SP - 776.e1 EP - 776.e9 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Rausch, Valentin A1 - Harbrecht, Andreas A1 - Kahmann, Stephanie Lucina A1 - Fenten, Thomas A1 - Jovanovic, Nebojsa A1 - Hackl, Michael A1 - Müller, Lars P. A1 - Staat, Manfred A1 - Wegmann, Kilian T1 - Osteosynthesis of Phalangeal Fractures: Biomechanical Comparison of Kirschner Wires, Plates, and Compression Screws JF - The Journal of Hand Surgery N2 - Purpose The aim of this study was to compare several osteosynthesis techniques (intramedullary headless compression screws, T-plates, and Kirschner wires) for distal epiphyseal fractures of proximal phalanges in a human cadaveric model. Methods A total of 90 proximal phalanges from 30 specimens (index, ring, and middle fingers) were used for this study. After stripping off all soft tissue, a transverse distal epiphyseal fracture was simulated at the proximal phalanx. The 30 specimens were randomly assigned to 1 fixation technique (30 per technique), either a 3.0-mm intramedullary headless compression screw, locking plate fixation with a 2.0-mm T-plate, or 2 oblique 1.0-mm Kirschner wires. Displacement analysis (bending, distraction, and torsion) was performed using optical tracking of an applied random speckle pattern after osteosynthesis. Biomechanical testing was performed with increasing cyclic loading and with cyclic load to failure using a biaxial torsion-tension testing machine. Results Cannulated intramedullary compression screws showed significantly less displacement at the fracture site in torsional testing. Furthermore, screws were significantly more stable in bending testing. Kirschner wires were significantly less stable than plating or screw fixation in any cyclic load to failure test setup. Conclusions Intramedullary compression screws are a highly stable alternative in the treatment of transverse distal epiphyseal phalangeal fractures. Kirschner wires seem to be inferior regarding displacement properties and primary stability. Clinical relevance Fracture fixation of phalangeal fractures using plate osteosynthesis may have the advantage of a very rigid reduction, but disadvantages such as stiffness owing to the more invasive surgical approach and soft tissue irritation should be taken into account. Headless compression screws represent a minimally invasive choice for fixation with good biomechanical properties. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jhsa.2020.04.010 SN - 0363-5023 VL - 45 IS - 10 SP - 987.e1 EP - 987.e8 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ramoshaba, Nthai E. A1 - Huisman, Hugo W. A1 - Lammertyn, Leandi A1 - Kotliar, Konstantin A1 - Schutte, Aletta E. A1 - Smith, Wayne T1 - Retinal microvasculature and masked hypertension in young adults: the African-PREDICT study JF - Hypertension Research N2 - Masked hypertension is known to induce microvascular complications. However, it is unclear whether early microvascular changes are already occurring in young, otherwise healthy adults. We therefore investigated whether retinal microvascular calibers and acute responses to a flicker stimulus are related to masked hypertension. We used the baseline data of 889 participants aged 20–30 years who were taking part in the African Prospective study on the Early Detection and Identification of Cardiovascular Disease and Hypertension. Clinic and 24-h ambulatory blood pressure were measured. The central retinal artery equivalent (CRAE) and central retinal vein equivalent were calculated from fundus images, and retinal vessel dilation was determined in response to flicker light-induced provocation. A smaller CRAE was observed in those with masked hypertension vs. those with normotension (157.1 vs. 161.2 measuring units, P < 0.001). In forward multivariable-adjusted regression analysis, only CRAE was negatively related to masked hypertension [adjusted R² = 0.267, β = −0.097 (95% CI = −0.165; −0.029), P = 0.005], but other retinal microvascular parameters were not associated with masked hypertension. In multivariable logistic regression analyses, masked hypertension [OR = 2.333, (95% CI = 1.316; 4.241), P = 0.004] was associated with a narrower CRAE. In young healthy adults, masked hypertension was associated with retinal arteriolar narrowing, thereby reflecting early microvascular alterations known to predict cardiovascular outcomes in later life. Y1 - 2020 U6 - http://dx.doi.org/10.1038/s41440-020-0487-0 SN - 1348-4214 IS - 43 SP - 1231 EP - 1238 PB - Springer Nature CY - Osaka ER - TY - CHAP A1 - Raman, Aravind Hariharan A1 - Jung, Alexander A1 - Horváth, András A1 - Becker, Nadine A1 - Staat, Manfred ED - Staat, Manfred ED - Erni, Daniel T1 - Modification of a computer model of human stem cell-derived cardiomyocyte electrophysiology based on Patch-Clamp measurements T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - Human induced pluripotent stem cells (hiPSCs) have shown to be promising in disease studies and drug screenings [1]. Cardiomyocytes derived from hiPSCs have been extensively investigated using patch-clamping and optical methods to compare their electromechanical behaviour relative to fully matured adult cells. Mathematical models can be used for translating findings on hiPSCCMs to adult cells [2] or to better understand the mechanisms of various ion channels when a drug is applied [3,4]. Paci et al. (2013) [3] developed the first model of hiPSC-CMs, which they later refined based on new data [3]. The model is based on iCells® (Fujifilm Cellular Dynamics, Inc. (FCDI), Madison WI, USA) but major differences among several cell lines and even within a single cell line have been found and motivate an approach for creating sample-specific models. We have developed an optimisation algorithm that parameterises the conductances (in S/F=Siemens/Farad) of the latest Paci et al. model (2018) [5] using current-voltage data obtained in individual patch-clamp experiments derived from an automated patch clamp system (Patchliner, Nanion Technologies GmbH, Munich). Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 10 EP - 11 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Rabner, Arthur A1 - Shacham, Yosi T1 - A concept for a sensitive micro total analysis system for high throughput fluorescence imaging N2 - This paper discusses possible methods for on-chip fluorescent imaging for integrated bio-sensors. The integration of optical and electro-optical accessories, according to suggested methods, can improve the performance of fluorescence imaging. It can boost the signal to background ratio by a few orders of magnitudes in comparison to conventional discrete setups. The methods that are present in this paper are oriented towards building reproducible arrays for high-throughput micro total analysis systems (µTAS). The first method relates to side illumination of the fluorescent material placed into microcompartments of the lab-on-chip. Its significance is in high utilization of excitation energy for low concentration of fluorescent material. The utilization of a transparent µLED chip, for the second method, allows the placement of the excitation light sources on the same optical axis with emission detector, such that the excitation and emission rays are directed controversly. The third method presents a spatial filtering of the excitation background. KW - Biosensor KW - Fluorescence KW - imaging KW - lab-on-chip KW - fluidic KW - lenslet array KW - LED chip KW - image sensor KW - biosensor Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1456 ER - TY - JOUR A1 - Rabehi, Amine A1 - Garlan, Benjamin A1 - Achtsnicht, Stefan A1 - Krause, Hans-Joachim A1 - Offenhäusser, Andreas A1 - Ngo, Kieu A1 - Neveu, Sophie A1 - Graff-Dubois, Stephanie A1 - Kokabi, Hamid T1 - Magnetic detection structure for Lab-on-Chip applications based on the frequency mixing technique JF - Sensors N2 - A magnetic frequency mixing technique with a set of miniaturized planar coils was investigated for use with a completely integrated Lab-on-Chip (LoC) pathogen sensing system. The system allows the detection and quantification of superparamagnetic beads. Additionally, in terms of magnetic nanoparticle characterization ability, the system can be used for immunoassays using the beads as markers. Analytical calculations and simulations for both excitation and pick-up coils are presented; the goal was to investigate the miniaturization of simple and cost-effective planar spiral coils. Following these calculations, a Printed Circuit Board (PCB) prototype was designed, manufactured, and tested for limit of detection, linear response, and validation of theoretical concepts. Using the magnetic frequency mixing technique, a limit of detection of 15 µg/mL of 20 nm core-sized nanoparticles was achieved without any shielding. KW - Lab-on-Chip KW - magnetic sensing KW - frequency mixing KW - superparamagnetic nanoparticles KW - magnetic beads Y1 - 2018 U6 - http://dx.doi.org/10.3390/s18061747 SN - 1424-8220 VL - 18 IS - 6 PB - MDPI CY - Basel ER - TY - JOUR A1 - Quittmann, Oliver J. A1 - Meskemper, Joshua A1 - Albracht, Kirsten A1 - Abel, Thomas A1 - Foitschik, Tina A1 - Strüder, Heiko K. T1 - Normalising surface EMG of ten upper-extremity muscles in handcycling: Manual resistance vs. sport-specific MVICs JF - Journal of Electromyography and Kinesiology N2 - Muscular activity in terms of surface electromyography (sEMG) is usually normalised to maximal voluntary isometric contractions (MVICs). This study aims to compare two different MVIC-modes in handcycling and examine the effect of moving average window-size. Twelve able-bodied male competitive triathletes performed ten MVICs against manual resistance and four sport-specific trials against fixed cranks. sEMG of ten muscles [M. trapezius (TD); M. pectoralis major (PM); M. deltoideus, Pars clavicularis (DA); M. deltoideus, Pars spinalis (DP); M. biceps brachii (BB); M. triceps brachii (TB); forearm flexors (FC); forearm extensors (EC); M. latissimus dorsi (LD) and M. rectus abdominis (RA)] was recorded and filtered using moving average window-sizes of 150, 200, 250 and 300 ms. Sport-specific MVICs were higher compared to manual resistance for TB, DA, DP and LD, whereas FC, TD, BB and RA demonstrated lower values. PM and EC demonstrated no significant difference between MVIC-modes. Moving average window-size had no effect on MVIC outcomes. MVIC-mode should be taken into account when normalised sEMG data are illustrated in handcycling. Sport-specific MVICs seem to be suitable for some muscles (TB, DA, DP and LD), but should be augmented by MVICs against manual/mechanical resistance for FC, TD, BB and RA. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jelekin.2020.102402 SN - 1050-6411 VL - 51 IS - Article 102402 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Quittmann, Oliver J. A1 - Abel, Thomas A1 - Albracht, Kirsten A1 - Strüder, Heiko K. T1 - Reliability of muscular activation patterns and their alterations during incremental handcycling in able-bodied participants JF - Sports Biomechanics Y1 - 2019 U6 - http://dx.doi.org/10.1080/14763141.2019.1593496 SN - 1752-6116 IS - Article in press PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Quittmann, Oliver J. A1 - Abel, Thomas A1 - Albracht, Kirsten A1 - Strüder, Heiko K. T1 - Biomechanics of all-out handcycling exercise: kinetics, kinematics and muscular activity of a 15-s sprint test in able-bodied participants JF - Sports Biomechanics N2 - This study aims to quantify the kinematics, kinetics and muscular activity of all-out handcycling exercise and examine their alterations during the course of a 15-s sprint test. Twelve able-bodied competitive triathletes performed a 15-s all-out sprint test in a recumbent racing handcycle that was attached to an ergometer. During the sprint test, tangential crank kinetics, 3D joint kinematics and muscular activity of 10 muscles of the upper extremity and trunk were examined using a power metre, motion capturing and surface electromyography (sEMG), respectively. Parameters were compared between revolution one (R1), revolution two (R2), the average of revolution 3 to 13 (R3) and the average of the remaining revolutions (R4). Shoulder abduction and internal-rotation increased, whereas maximal shoulder retroversion decreased during the sprint. Except for the wrist angles, angular velocity increased for every joint of the upper extremity. Several muscles demonstrated an increase in muscular activation, an earlier onset of muscular activation in crank cycle and an increased range of activation. During the course of a 15-s all-out sprint test in handcycling, the shoulder muscles and the muscles associated to the push phase demonstrate indications for short-duration fatigue. These findings are helpful to prevent injuries and improve performance in all-out handcycling. KW - Handbike KW - sEMG KW - Paralympic sport KW - performance testing KW - high-intensity exercise Y1 - 2022 U6 - http://dx.doi.org/10.1080/14763141.2020.1745266 SN - 1752-6116 (Onlineausgabe) SN - 1476-3141 (Druckausgabe) VL - 21 IS - 10 SP - 1200 EP - 1223 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Quittmann, Oliver J. A1 - Abel, Thomas A1 - Albracht, Kirsten A1 - Meskemper, Joshua A1 - Foitschik, Tina A1 - Strüder, Heiko K. T1 - Biomechanics of handcycling propulsion in a 30-min continuous load test at lactate threshold: Kinetics, kinematics, and muscular activity in able-bodied participants JF - European Journal of Applied Physiology N2 - Purpose This study aims to investigate the biomechanics of handcycling during a continuous load trial (CLT) to assess the mechanisms underlying fatigue in upper body exercise. Methods Twelve able-bodied triathletes performed a 30-min CLT at a power output corresponding to lactate threshold in a racing recumbent handcycle mounted on a stationary ergometer. During the CLT, ratings of perceived exertion (RPE), tangential crank kinetics, 3D joint kinematics, and muscular activity of ten muscles of the upper extremity and trunk were examined using motion capturing and surface electromyography. Results During the CLT, spontaneously chosen cadence and RPE increased, whereas crank torque decreased. Rotational work was higher during the pull phase. Peripheral RPE was higher compared to central RPE. Joint range of motion decreased for elbow-flexion and radial-duction. Integrated EMG (iEMG) increased in the forearm flexors, forearm extensors, and M. deltoideus (Pars spinalis). An earlier onset of activation was found for M. deltoideus (Pars clavicularis), M. pectoralis major, M. rectus abdominis, M. biceps brachii, and the forearm flexors. Conclusion Fatigue-related alterations seem to apply analogously in handcycling and cycling. The most distal muscles are responsible for force transmission on the cranks and might thus suffer most from neuromuscular fatigue. The findings indicate that peripheral fatigue (at similar lactate values) is higher in handcycling compared to leg cycling, at least for inexperienced participants. An increase in cadence might delay peripheral fatigue by a reduced vascular occlusion. We assume that the gap between peripheral and central fatigue can be reduced by sport-specific endurance training. Y1 - 2020 U6 - http://dx.doi.org/10.1007/s00421-020-04373-x SN - 1439-6327 IS - 120 SP - 1403 EP - 1415 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Pöttgen, Philipp A1 - Ederer, Thorsten A1 - Altherr, Lena A1 - Pelz, Peter F. T1 - Developing a control strategy for booster stations under uncertain load JF - Applied Mechanics and Materials N2 - Booster stations can fulfill a varying pressure demand with high energy-efficiency, because individual pumps can be deactivated at smaller loads. Although this is a seemingly simple approach, it is not easy to decide precisely when to activate or deactivate pumps. Contemporary activation controls derive the switching points from the current volume flow through the system. However, it is not measured directly for various reasons. Instead, the controller estimates the flow based on other system properties. This causes further uncertainty for the switching decision. In this paper, we present a method to find a robust, yet energy-efficient activation strategy. KW - Technical Operations Research (TOR) KW - Booster Station KW - Pump System KW - Discrete Optimization Y1 - 2015 SN - 1662-7482 U6 - http://dx.doi.org/10.4028/www.scientific.net/AMM.807.241 N1 - Ebenfalls weltweit einsehbar unter: http://wl.fst.tu-darmstadt.de/wl/publications/paper_151123_SFB805_ ICUME_Developing_a_Control_Strategy_for_Booster_Stations_under_Uncertain_Load_poettgen_ederer_pelz_altherr.pdf VL - 807 IS - 807 SP - 241 EP - 246 PB - Trans Tech Publications CY - Bäch ER - TY - JOUR A1 - Probst, M. A1 - Behbahani, Mehdi A1 - Borrmann, E. A1 - Elgeti, S. A1 - Nicolai, M. A1 - Behr, M. T1 - Hemodynamic Modeling for Numerical Analysis and Design of Medical Devices Y1 - 2010 N1 - Posterpresentation ; NIC Symposium 2010 ; 24 - 25 February 2010 Jülich, Germany ER - TY - JOUR A1 - Pressler, Axel A1 - Esefeld, Katrin A1 - Scherr, Johannes A1 - Ali, Mohammad A1 - Hanssen, Henner A1 - Kotliar, Konstantin A1 - Lanzl, Ines A1 - Halle, Martin A1 - Kaemmerer, Harald A1 - Schmidt-Trucksäss, Arno A1 - Hager, Alfred T1 - Structural alterations of retinal arterioles in adults late after repair of aortic isthmic coarctation JF - The American Journal of Cardiology N2 - Patients after coarctation repair still have an increased risk of cardiovascular or cerebrovascular events. This has been explained by the persisting hypertension and alterations in the peripheral vessels. However, involvement of the central vessels such as the retinal arteries is virtually unknown. A total of 34 patients after coarctation repair (22 men and 12 women; 23 to 58 years old, age range 0 to 32 years at surgical repair) and 34 nonhypertensive controls underwent structural and functional retinal vessel analysis. Using structural analysis, the vessel diameters were measured. Using functional analysis, the endothelium-dependent vessel dilation in response to flicker light stimulation was assessed. In the patients after coarctation repair, the retinal arteriolar diameter was significantly reduced compared to that of the controls (median 182 μm, first to third quartile 171 to 197; vs 197 μm, first to third quartile 193 to 206; p <0.001). These findings were independent of the peripheral blood pressure and age at intervention. No differences were found for venules. The functional analysis findings were not different between the patients and controls (maximum dilation 3.5%, first to third quartile 2.1% to 4.5% vs 3.6%, first to third quartile 2.2% to 4.3%; p = 0.81), indicating preserved autoregulative mechanisms. In conclusion, the retinal artery diameter is reduced in patients after coarctation repair, independent of their current blood pressure level and age at intervention. As a structural marker of chronic vessel damage associated with past, current, or future hypertension, retinal arteriolar narrowing has been linked to stroke incidence. These results indicate an involvement of cerebral microcirculation in aortic coarctation, despite timely repair, and might contribute to explain the increased rate of cerebrovascular events in such patients. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.amjcard.2009.10.070 SN - 0002-9149 VL - 105 IS - 5 SP - 740 EP - 744 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Preiß, C. A1 - Linder, Peter A1 - Wendt, K. A1 - Krystek, M. A1 - Digel, Ilya A1 - Gossmann, Matthias A1 - Temiz Artmann, Aysegül A1 - Porst, Dariusz A1 - Kayser, Peter A1 - Bassam, Rasha A1 - Artmann, Gerhard T1 - Engineering technology for plant physiology and plant stress research N2 - Plant physiology and plant stress: Plant physiology will be much more important for human mankind because of yield and cultivation limits of crops determined by their resistance to stress. To assess and counteract various stress factors it is necessary to conduct plant research to gain information and results on plant physiology. KW - Pflanzenphysiologie KW - Pflanzenstress KW - Pflanzenscanner KW - plant stress KW - plant scanner Y1 - 2011 ER - TY - JOUR A1 - Pourshahidi, Ali Mohammad A1 - Engelmann, Ulrich M. A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Resolving ambiguities in core size determination of magnetic nanoparticles from magnetic frequency mixing data JF - Journal of Magnetism and Magnetic Materials N2 - Frequency mixing magnetic detection (FMMD) has been widely utilized as a measurement technique in magnetic immunoassays. It can also be used for the characterization and distinction (also known as “colourization”) of different types of magnetic nanoparticles (MNPs) based on their core sizes. In a previous work, it was shown that the large particles contribute most of the FMMD signal. This leads to ambiguities in core size determination from fitting since the contribution of the small-sized particles is almost undetectable among the strong responses from the large ones. In this work, we report on how this ambiguity can be overcome by modelling the signal intensity using the Langevin model in thermodynamic equilibrium including a lognormal core size distribution fL(dc,d0,σ) fitted to experimentally measured FMMD data of immobilized MNPs. For each given median diameter d0, an ambiguous amount of best-fitting pairs of parameters distribution width σ and number of particles Np with R2 > 0.99 are extracted. By determining the samples’ total iron mass, mFe, with inductively coupled plasma optical emission spectrometry (ICP-OES), we are then able to identify the one specific best-fitting pair (σ, Np) one uniquely. With this additional externally measured parameter, we resolved the ambiguity in core size distribution and determined the parameters (d0, σ, Np) directly from FMMD measurements, allowing precise MNPs sample characterization. Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.jmmm.2022.169969 SN - 0304-8853 VL - 563 IS - In progress, Art. No. 169969 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Porschen, W. A1 - Gartzen, J. A1 - Gewehr, K. A1 - Mühlensiepen, H. A1 - Weber, Hans-Joachim A1 - [u.a.], T1 - In vivo assay of the radiation sensitivity of hypoxic tumour cells : influence of γ-rays, cyclotron neutrons, misonidazole, hyperthermia and mixed modalities JF - The British journal of cancer / Supplement N2 - Tumour cell death can be evaluated in the living mouse by externally measuring the rate of loss of tumour-bound DNA tracer. By sequentially labelling the tumour-bearing animals with ¹²⁵IUdR and ¹³¹IUdR 50 h apart, the average tumour cells at the time of the second injection are labelled by ¹²⁵IUdR and the euoxic tumour cells are specifically labelled with ¹³¹IUdR. Tumour treatment at this stage of labelling permits the observation of the reaction of euoxic cells and average tumour cells and finally yields data on hypoxic cells and thus on the oxygen enhancement ratio. This information adds to results from tumour control and growth delay. With this technique effects were analysed of 60-Co γ-rays, cyclotron neutrons (E = 6 MeV), misonidazole (500 mg/kg body wt) and hyperthermia (42°C water-bath), or combinations of these. Misonidazole (15 min before irradiation) altered the oxygen enhancement ratio by a factor of 1·5 for γ-rays and of 1·1 for neutrons; when evaluated from tumour-growth delay and TCD-50 misonidazole gave a dose modifying factor of 1·47 for γ-rays and of 1·2-1·3 for neutrons. Based on percentage tumour regression 100 days after treatment, the enhancement ratio from hyperthermia (after irradiation) was 2·75 for γ-rays (at 10 Gray) and 2·2 for neutrons (at 3·2 Gray). For neutrons combined with misonidazole and hyperthermia the ratio was 2·4. These results demonstrate that effects of neutron irradiation may be modified by electron-affinic substances and/or hyperthermia. Y1 - 1978 SN - 0306-9443 N1 - Section 6: Sensitization and Hypoxic Cytotoxicity: Effects of Hyperthermia and High Let IS - 3 SP - 194 EP - 197 PB - Lewis CY - London ER - TY - JOUR A1 - Pookhalil, Ali A1 - Amoabediny, Ghassem A1 - Tabesh, Hadi A1 - Behbahani, Mehdi A1 - Mottaghy, Khosrow T1 - A new approach for semiempirical modeling of mechanical blood trauma JF - The international journal of artificial organs N2 - Purpose Two semi-empirical models were recently published, both making use of existing literature data, but each taking into account different physical phenomena that trigger hemolysis. In the first model, hemoglobin (Hb) release is described as a permeation procedure across the membrane, assuming a shear stress-dependent process (sublethal model). The second model only accounts for hemoglobin release that is caused by cell membrane breakdown, which occurs when red blood cells (RBC) undergo mechanically induced shearing for a period longer than the threshold time (nonuniform threshold model). In this paper, we introduce a model that considers the hemolysis generated by both these possible phenomena. Methods Since hemolysis can possibly be caused by permeation of hemoglobin through the RBC functional membrane as well as by release of hemoglobin from RBC membrane breakdown, our proposed model combines both these models. An experimental setup consisting of a Couette device was utilized for validation of our proposed model. Results A comparison is presented between the damage index (DI) predicted by the proposed model vs. the sublethal model vs. the nonthreshold model and experimental datasets. This comparison covers a wide range of shear stress for both human and porcine blood. An appropriate agreement between the measured DI and the DI predicted by the present model was obtained. Conclusions The semiempirical hemolysis model introduced in this paper aims for significantly enhanced conformity with experimental data. Two phenomenological outcomes become possible with the proposed approach: an estimation of the average time after which cell membrane breakdown occurs under the applied conditions, and a prediction of the ratio between the phenomena involved in hemolysis. Y1 - 2016 U6 - http://dx.doi.org/10.5301/ijao.5000474 SN - 1724-6040 VL - 39 IS - 4 SP - 171 EP - 177 PB - Sage CY - London ER - TY - CHAP A1 - Pohle-Fröhlich, Regina A1 - Dalitz, Christoph A1 - Richter, Charlotte A1 - Hahnen, Tobias A1 - Stäudle, Benjamin A1 - Albracht, Kirsten T1 - Estimation of muscle fascicle orientation in ultrasonic images T2 - VISIGRAPP 2020 - Proceedings of the 15th International Joint Conference on Computer Vision, Imaging and Computer Graphics Theory and Applications, 5 Y1 - 2020 SP - 79 EP - 86 ER - TY - JOUR A1 - Pogorelova, Natalia A1 - Rogachev, Evgeniy A1 - Digel, Ilya A1 - Chernigova, Svetlana A1 - Nardin, Dmitry T1 - Bacterial Cellulose Nanocomposites: Morphology and Mechanical Properties JF - Materials N2 - Bacterial cellulose (BC) is a promising material for biomedical applications due to its unique properties such as high mechanical strength and biocompatibility. This article describes the microbiological synthesis, modification, and characterization of the obtained BC-nanocomposites originating from symbiotic consortium Medusomyces gisevii. Two BC-modifications have been obtained: BC-Ag and BC-calcium phosphate (BC-Ca3(PO4)2). Structure and physicochemical properties of the BC and its modifications were investigated by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), atomic force microscopy (AFM), and infrared Fourier spectroscopy as well as by measurements of mechanical and water holding/absorbing capacities. Topographic analysis of the surface revealed multicomponent thick fibrils (150–160 nm in diameter and about 15 µm in length) constituted by 50–60 nm nanofibrils weaved into a left-hand helix. Distinctive features of Ca-phosphate-modified BC samples were (a) the presence of 500–700 nm entanglements and (b) inclusions of Ca3(PO4)2 crystals. The samples impregnated with Ag nanoparticles exhibited numerous roundish inclusions, about 110 nm in diameter. The boundaries between the organic and inorganic phases were very distinct in both cases. The Ag-modified samples also showed a prominent waving pattern in the packing of nanofibrils. The obtained BC gel films possessed water-holding capacity of about 62.35 g/g. However, the dried (to a constant mass) BC-films later exhibited a low water absorption capacity (3.82 g/g). It was found that decellularized BC samples had 2.4 times larger Young’s modulus and 2.2 times greater tensile strength as compared to dehydrated native BC films. We presume that this was caused by molecular compaction of the BC structure. Y1 - 2020 SN - 1996-1944 U6 - http://dx.doi.org/10.3390/ma13122849 VL - 13 IS - 12 SP - 1 EP - 16 PB - MDPI CY - Basel ER - TY - JOUR A1 - Pogorelova, Natalia A1 - Rogachev, Evgeniy A1 - Akimbekov, Nuraly A1 - Digel, Ilya T1 - Effect of dehydration method on the micro- and nanomorphological properties of bacterial cellulose produced by Medusomyces gisevii on different substrates JF - Journal of materials science N2 - Many important properties of bacterial cellulose (BC), such as moisture absorption capacity, elasticity and tensile strength, largely depend on its structure. This paper presents a study on the effect of the drying method on BC films produced by Medusomyces gisevii using two different procedures: room temperature drying (RT, (24 ± 2 °C, humidity 65 ± 1%, dried until a constant weight was reached) and freeze-drying (FD, treated at − 75 °C for 48 h). BC was synthesized using one of two different carbon sources—either glucose or sucrose. Structural differences in the obtained BC films were evaluated using atomic force microscopy (AFM), scanning electron microscopy (SEM), and X-ray diffraction. Macroscopically, the RT samples appeared semi-transparent and smooth, whereas the FD group exhibited an opaque white color and sponge-like structure. SEM examination showed denser packing of fibrils in FD samples while RT-samples displayed smaller average fiber diameter, lower surface roughness and less porosity. AFM confirmed the SEM observations and showed that the FD material exhibited a more branched structure and a higher surface roughness. The samples cultivated in a glucose-containing nutrient medium, generally displayed a straight and ordered shape of fibrils compared to the sucrose-derived BC, characterized by a rougher and wavier structure. The BC films dried under different conditions showed distinctly different crystallinity degrees, whereas the carbon source in the culture medium was found to have a relatively small effect on the BC crystallinity. Y1 - 2024 U6 - http://dx.doi.org/10.1007/s10853-024-09596-3 SN - 1573-4803 (Online) SN - 0022-2461 (Print) N1 - Corresponding author: Ilya Digel VL - 2024 PB - Springer Science + Business Media CY - Dordrecht ER - TY - JOUR A1 - Poghossian, Arshak A1 - Yoshinobu, Tatsuo A1 - Simonis, A. A1 - Ecken, H. A1 - Lüth, Hans A1 - Schöning, Michael Josef T1 - Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS? JF - Sensors and Actuators B. 78 (2001), H. 1-3 Y1 - 2001 SN - 0925-4005 SP - 237 EP - 242 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Yoshinobu, Tatsuo A1 - Schöning, Michael Josef T1 - Flow-velocity microsensors based on semiconductor field-effect structures JF - Sensors. 3 (2003), H. 7 Y1 - 2003 SN - 1424-8220 SP - 202 EP - 212 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Yoshinobu, T. A1 - Simonis, A. A1 - Ecken, H. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Penicillin detection by means of field-effect based sensors: EnFET, capacitive EIS sensor or LAPS? JF - Proceedings : Copenhagen, Denmark, 27 - 30 August 2000 / [ed.: R. de Reus ...] Y1 - 2000 SN - 87-89935-50-0 N1 - Eurosensors ; (14, 2000, København) ; Eurosensors ; (14 : ; 2000.08.27-30 : ; Copenhagen) ; European Conference on Solid-State Transducers ; (14 : ; 2000.08.27-30 : ; Copenhagen) SP - 27 EP - 30 PB - MIC, Mikroelektronik Centret CY - Lyngby, Denmark ER - TY - JOUR A1 - Poghossian, Arshak A1 - Werner, Frederik A1 - Buniatyan, V. V. A1 - Wagner, Torsten A1 - Miamoto, K. A1 - Yoshinobu, T. A1 - Schöning, Michael Josef T1 - Towards addressability of light-addressable potentiometric sensors: Shunting effect of non-illuminated region and cross-talk JF - Sensor and Actuators B: Chemical N2 - The LAPS (light-addressable potentiometric sensor) platform is one of the most attractive approaches for chemical and biological sensing with many applications ranging from pH and ion/analyte concentration measurements up to cell metabolism detection and chemical imaging. However, although it is generally accepted that LAPS measurements are spatially resolved, the light-addressability feature of LAPS devices has not been discussed in detail so far. In this work, an extended electrical equivalent-circuit model of the LAPS has been presented, which takes into account possible cross-talk effects due to the capacitive coupling of the non-illuminated region. A shunting effect of the non-illuminated area on the measured photocurrent and addressability of LAPS devices has been studied. It has been shown, that the measured photocurrent will be determined not only by the local interfacial potential in the illuminated region but also by possible interfacial potential changes in the non-illuminated region, yielding cross-talk effects. These findings were supported by the experimental investigations of a penicillin-sensitive multi-spot LAPS and a metal-insulator-semiconductor LAPS as model systems. Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.snb.2017.01.047 SN - 0925-4005 IS - 244 SP - 1071 EP - 1079 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Poghossian, Arshak A1 - Weiland, Maryam A1 - Schöning, Michael Josef ED - Lvova, Larisa ED - Kirsanov, Dmitry ED - di Natale, Corrado ED - Legin, Audrey T1 - Nanoplate field-effect capacitors: a new transducer structure for multiparameter (bio-)chemical sensing T2 - Multisensor system for chemical analysis : materials and sensors N2 - An array of electrically isolated nanoplate field-effect silicon-on-insulator (SOI) capacitors as a new transducer structure for multiparameter (bio-)chemical sensing is presented. The proposed approach allows addressable biasing and electrical readout of multiple nanoplate field-effect capacitive (bio-)chemical sensors on the same SOI chip, as well as differential-mode measurements. The realized sensor chip has been applied for pH and penicillin concentration measurements, electrical monitoring of polyelectrolyte multilayer formation, and the label-free electrical detection of consecutive deoxyribonucleic acid (DNA) hybridization and denaturation events. Y1 - 2014 SN - 978-981-4411-15-8 ; 978-981-4411-16-5 U6 - http://dx.doi.org/10.1201/b15491-11 SP - 333 EP - 373 PB - Jenny Stanford Publishing CY - Singapore ET - 1 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Weil, M. H. A1 - Bäcker, Matthias A1 - Mayer, D. A1 - Schöning, Michael Josef T1 - Field-effect Devices Functionalised with Gold-Nanoparticle/Macromolecule Hybrids: New Opportunities for a Label-Free Biosensing JF - Procedia Engineering N2 - Field-effect capacitive electrolyte-insulator-semiconductor (EIS) sensors functionalised with citrate-capped gold nanoparticles (AuNP) have been used for the electrostatic detection of macromolecules by their intrinsic molecular charge. The EIS sensor detects the charge changes in the AuNP/macromolecule hybrids induced by the adsorption or binding events. A feasibility of the proposed detection scheme has been exemplary demonstrated by realising EIS sensors for the detection of poly-D-lysine molecules. Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.proeng.2012.09.136 SN - 1877-7058 N1 - Part of special issue "26th European Conference on Solid-State Transducers, EUROSENSOR 2012" IS - 47 SP - 273 EP - 276 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Weil, M. A1 - Cherstvy, A. G. A1 - Schöning, Michael Josef T1 - Electrical monitoring of polyelectrolyte multilayer formation by means of capacitive field-effect devices JF - Analytical and bioanalytical chemistry N2 - The semiconductor field-effect platform represents a powerful tool for detecting the adsorption and binding of charged macromolecules with direct electrical readout. In this work, a capacitive electrolyte–insulator–semiconductor (EIS) field-effect sensor consisting of an Al-p-Si-SiO2 structure has been applied for real-time in situ electrical monitoring of the layer-by-layer formation of polyelectrolyte (PE) multilayers (PEM). The PEMs were deposited directly onto the SiO2 surface without any precursor layer or drying procedures. Anionic poly(sodium 4-styrene sulfonate) and cationic weak polyelectrolyte poly(allylamine hydrochloride) have been chosen as a model system. The effect of the ionic strength of the solution, polyelectrolyte concentration, number and polarity of the PE layers on the characteristics of the PEM-modified EIS sensors have been studied by means of capacitance–voltage and constant-capacitance methods. In addition, the thickness, surface morphology, roughness and wettabilityof the PE mono- and multilayers have been characterised by ellipsometry, atomic force microscopy and water contact-angle methods, respectively. To explain potential oscillations on the gate surface and signal behaviour of the capacitive field-effect EIS sensor modified with a PEM, a simplified electrostatic model that takes into account the reduced electrostatic screening of PE charges by mobile ions within the PEM has been proposed and discussed. Y1 - 2013 U6 - http://dx.doi.org/10.1007/s00216-013-6951-9 SN - 1432-1130 ; 1618-2642 VL - 405 IS - 20 SP - 6425 EP - 6436 PB - Springer CY - Berlin ER - TY - JOUR A1 - Poghossian, Arshak A1 - Wagner, Holger A1 - Schöning, Michael Josef T1 - Functional testing and characterisation of (bio-)chemical sensors on wafer level JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 835 EP - 838 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Wagner, Holger A1 - Schöning, Michael Josef T1 - Functional testing and characterisation of (bio-)chemical sensors on wafer level JF - Sensors and Actuators B: Chemical. 154 (2011), H. 2 Y1 - 2011 SN - 1873-3077 N1 - EUROSENSORS XXIII SP - 169 EP - 173 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Thust, M. A1 - Schöning, Michael Josef A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Cross-sensitivity of a capacitive penicillin sensor combined with a diffusion barrier JF - Sensors and Actuators B. 68 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 260 EP - 265 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Thust, M. A1 - Schroth, P. A1 - Steffen, A. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Penicillin detection by means of silicon-based field-effect structures JF - Sensors and Materials. 13 (2001), H. 4 Y1 - 2001 SN - 0392-2510 SP - 207 EP - 223 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Simonis, A. A1 - Lüth, H. T1 - An ISFET-based penicillin sensor with high sensitivity, low detection limit and long lifetime JF - Sensors and Actuators B. 76 (2001), H. 1-3 Y1 - 2001 SN - 0925-4005 SP - 519 EP - 526 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Detecting Both Physical and (Bio-)Chemical Parameters by Means of ISFET Devices JF - Electroanalysis. 16 (2004), H. 22 Y1 - 2004 SN - 1040-0397 SP - 1863 EP - 1872 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - "High-order” hybrid FET module for (bio)chemical and physical sensing JF - Integrated analytical systems / ed. by Salvador Alegret Y1 - 2003 SN - 0-444-51037-0 SP - 587 EP - 623 PB - Elsevier CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Chemical and biological field-effect sensors for liquids – a status report JF - Handbook of biosensors and biochips / ed. Robert S. Marks ... Bd. 1 Y1 - 2007 SN - 978-0-470-01905-4 SP - 395 EP - 412 PB - Wiley CY - Chichester ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Silicon-based chemical and biological field-effect sensors T2 - Encyclopedia of Sensors. Vol. 9 S - Sk Y1 - 2006 SN - 1-58883-065-9 SP - 463 EP - 534 PB - ASP, American Scientific Publ. CY - Stevenson Ranch, Calif. ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Nanomaterial-Modified Capacitive Field-Effect Biosensors T2 - Springer Series on Chemical Sensors and Biosensors (Methods and Applications) N2 - The coupling of charged molecules, nanoparticles, and more generally, inorganic/organic nanohybrids with semiconductor field-effect devices based on an electrolyte–insulator–semiconductor (EIS) system represents a very promising strategy for the active tuning of electrochemical properties of these devices and, thus, opening new opportunities for label-free biosensing by the intrinsic charge of molecules. The simplest field-effect sensor is a capacitive EIS sensor, which represents a (bio-)chemically sensitive capacitor. In this chapter, selected examples of recent developments in the field of label-free biosensing using nanomaterial-modified capacitive EIS sensors are summarized. In the first part, we present applications of EIS sensors modified with negatively charged gold nanoparticles for the label-free electrostatic detection of positively charged small proteins and macromolecules, for monitoring the layer-by-layer formation of oppositely charged polyelectrolyte (PE) multilayers as well as for the development of an enzyme-based biomolecular logic gate. In the second part, examples of a label-free detection by means of EIS sensors modified with a positively charged weak PE layer are demonstrated. These include electrical detection of on-chip and in-solution hybridized DNA (deoxyribonucleic acid) as well as an EIS sensor with pH-responsive weak PE/enzyme multilayers for enhanced field-effect biosensing. KW - Biomolecular logic gate KW - DNA KW - Enzyme biosensor KW - Field-effect sensor KW - Gold nanoparticle Y1 - 2017 U6 - http://dx.doi.org/10.1007/5346_2017_2 SP - 1 EP - 25 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Label-free sensing of biomolecules with field-effect devices for clinical applications JF - Electroanalysis N2 - Among the variety of transducer concepts proposed for label-free detection of biomolecules, the semiconductor field-effect device (FED) is one of the most attractive platforms. As medical techniques continue to progress towards diagnostic and therapies based on biomarkers, the ability of FEDs for a label-free, fast and real-time detection of multiple pathogenic and physiologically relevant molecules with high specificity and sensitivity offers very promising prospects for their application in point-of-care and personalized medicine for an early diagnosis and treatment of diseases. The presented paper reviews recent advances and current trends in research and development of different FEDs for label-free, direct electrical detection of charged biomolecules by their intrinsic molecular charge. The authors are mainly focusing on the detection of the DNA hybridization event, antibody-antigen affinity reaction as well as clinically relevant biomolecules such as cardiac and cancer biomarkers. Y1 - 2014 U6 - http://dx.doi.org/10.1002/elan.201400073 SN - 1521-4109 (E-Journal); 1040-0397 (Print) VL - 26 IS - 6 SP - 1197 EP - 1213 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Capacitive field-effect eis chemical sensors and biosensors: A status report JF - Sensors N2 - Electrolyte-insulator-semiconductor (EIS) field-effect sensors belong to a new generation of electronic chips for biochemical sensing, enabling a direct electronic readout. The review gives an overview on recent advances and current trends in the research and development of chemical sensors and biosensors based on the capacitive field-effect EIS structure—the simplest field-effect device, which represents a biochemically sensitive capacitor. Fundamental concepts, physicochemical phenomena underlying the transduction mechanism and application of capacitive EIS sensors for the detection of pH, ion concentrations, and enzymatic reactions, as well as the label-free detection of charged molecules (nucleic acids, proteins, and polyelectrolytes) and nanoparticles, are presented and discussed. Y1 - 2020 U6 - http://dx.doi.org/10.3390/s20195639 SN - 1424-8220 VL - 20 IS - 19 PB - MDPI CY - Basel ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Recent progress in silicon-based biologically sensitive field-effect devices JF - Current Opinion in Electrochemistry N2 - Biologically sensitive field-effect devices (BioFEDs) advantageously combine the electronic field-effect functionality with the (bio)chemical receptor’s recognition ability for (bio)chemical sensing. In this review, basic and widely applied device concepts of silicon-based BioFEDs (ion-sensitive field-effect transistor, silicon nanowire transistor, electrolyte-insulator-semiconductor capacitor, light-addressable potentiometric sensor) are presented and recent progress (from 2019 to early 2021) is discussed. One of the main advantages of BioFEDs is the label-free sensing principle enabling to detect a large variety of biomolecules and bioparticles by their intrinsic charge. The review encompasses applications of BioFEDs for the label-free electrical detection of clinically relevant protein biomarkers, deoxyribonucleic acid molecules and viruses, enzyme-substrate reactions as well as recording of the cell acidification rate (as an indicator of cellular metabolism) and the extracellular potential. Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.coelec.2021.100811 SN - 2451-9103 IS - Article number: 100811 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schusser, Sebastian A1 - Bäcker, M. A1 - Leinhos, Marcel A1 - Schöning, Michael Josef T1 - Real-time in-situ electrical monitoring of the degradation of biopolymers using semiconductor field-effect devices T2 - Biodegradable biopolymers. Vol. 1 Y1 - 2015 SN - 978-1-63483-632-6 SP - 135 EP - 153 PB - Nova Science Publ. CY - Hauppauge ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schumacher, Kerstin A1 - Kloock, Joachim P. A1 - Rosenkranz, Christian A1 - Schultze, Joachim W. A1 - Müller-Veggian, Mattea A1 - Schöning, Michael Josef T1 - Functional testing and characterisation of ISFETs on wafer level by means of a micro-droplet cell N2 - A wafer-level functionality testing and characterisation system for ISFETs (ionsensitive field-effect transistor) is realised by means of integration of a specifically designed capillary electrochemical micro-droplet cell into a commercial wafer prober-station. The developed system allows the identification and selection of “good” ISFETs at the earliest stage and to avoid expensive bonding, encapsulation and packaging processes for nonfunctioning ISFETs and thus, to decrease costs, which are wasted for bad dies. The developed system is also feasible for wafer-level characterisation of ISFETs in terms of sensitivity, hysteresis and response time. Additionally, the system might be also utilised for wafer-level testing of further electrochemical sensors. KW - Biosensor KW - Biosensorik KW - ISFET KW - Wafer KW - ISFET KW - wafer-level testing KW - capillary micro-droplet cell Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1259 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schultze, J. W. A1 - Schöning, Michael Josef T1 - Application of a (bio-)chemical sensor (ISFET) for the detection of physical parameters in liquids JF - Electrochimica Acta. 48 (2003), H. 20-22 Y1 - 2003 SP - 3289 EP - 3297 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schultze, J. W. A1 - Schöning, Michael Josef T1 - Multi-parameter detection of (bio-)chemical and physical quantities using an identical transducer principle JF - Sensors and Actuators B. 91 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 83 EP - 91 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Platen, J. A1 - Schöning, Michael Josef T1 - Towards self-aligned nanostructures by means of layerexpansion technique JF - Electrochimica Acta. 51 (2005), H. 5 Y1 - 2005 SN - 0013-4686 SP - 838 EP - 843 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Malzahn, K. A1 - Abouzar, Maryam H. A1 - Mehndiratta, P. A1 - Katz, E. A1 - Schöning, Michael Josef T1 - Integration of biomolecular logic gates with field-effect transducers JF - Electrochimica Acta. 56 (2011), H. 26 Y1 - 2011 SN - 0013-4686 SP - 9661 EP - 9665 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Mai, D.-T. A1 - Mourzina, Y. A1 - Schöning, Michael Josef T1 - Impedance effect of an ion-sensitive membrane: characterisation of an EMIS sensor by impedance spectroscopy, capacitance-voltage and constant-capacitance method JF - Sensors and Actuators B. 103 (2004), H. 1-2 Y1 - 2004 SN - 0925-4005 SP - 423 EP - 428 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Lüth, H. A1 - Schultze, J. W. A1 - Schöning, Michael Josef T1 - (Bio-)chemical and physical microsensor array using an identical transducer principle JF - Scaling down in electrochemistry : electrochemical micro- and nanosystem technology ; proceedings of the 3rd International Symposium on Electrochemical Microsystem Technologies, Garmisch-Patenkirchen, Germany, 11 - 15 September 2000 / ed. by J. W. Schultz Y1 - 2001 SN - 0-08-044014-2 SP - 243 EP - 249 PB - Elsevier [u.a.] CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Poghossian, Arshak A1 - Krämer, Melina A1 - Abouzar, Maryam H. A1 - Pita, Marcos A1 - Katz, Evgeny A1 - Schöning, Michael Josef T1 - Interfacing of biocomputing systems with silicon chips: Enzyme logic gates based on field-effect devices JF - Procedia Chemistry. 1 (2009), H. 1 Y1 - 2009 SN - 1876-6196 N1 - Proceedings of the Eurosensors XXIII conference ; Eurosensors 23 SP - 682 EP - 685 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Katz, Evgeny A1 - Schöning, Michael Josef T1 - Enzyme logic AND-Reset and OR-Reset gates based on a field-effect electronic transducer modified with multi-enzyme membrane JF - Chemical Communications N2 - Capacitive field-effect sensors modified with a multi-enzyme membrane have been applied for an electronic transduction of biochemical signals processed by enzyme-based AND-Reset and OR-Reset logic gates. The local pH change at the sensor surface induced by the enzymatic reaction was used for the activation of the Reset function for the first time. Y1 - 2015 U6 - http://dx.doi.org/10.1039/C5CC01362C VL - 51 SP - 6564 EP - 6567 PB - Royal Society of Chemistry (RSC) CY - Cambridge ER - TY - JOUR A1 - Poghossian, Arshak A1 - Jablonski, Melanie A1 - Molinnus, Denise A1 - Wege, Christina A1 - Schöning, Michael Josef T1 - Field-Effect Sensors for Virus Detection: From Ebola to SARS-CoV-2 and Plant Viral Enhancers JF - Frontiers in Plant Science N2 - Coronavirus disease 2019 (COVID-19) is a novel human infectious disease provoked by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Currently, no specific vaccines or drugs against COVID-19 are available. Therefore, early diagnosis and treatment are essential in order to slow the virus spread and to contain the disease outbreak. Hence, new diagnostic tests and devices for virus detection in clinical samples that are faster, more accurate and reliable, easier and cost-efficient than existing ones are needed. Due to the small sizes, fast response time, label-free operation without the need for expensive and time-consuming labeling steps, the possibility of real-time and multiplexed measurements, robustness and portability (point-of-care and on-site testing), biosensors based on semiconductor field-effect devices (FEDs) are one of the most attractive platforms for an electrical detection of charged biomolecules and bioparticles by their intrinsic charge. In this review, recent advances and key developments in the field of label-free detection of viruses (including plant viruses) with various types of FEDs are presented. In recent years, however, certain plant viruses have also attracted additional interest for biosensor layouts: Their repetitive protein subunits arranged at nanometric spacing can be employed for coupling functional molecules. If used as adapters on sensor chip surfaces, they allow an efficient immobilization of analyte-specific recognition and detector elements such as antibodies and enzymes at highest surface densities. The display on plant viral bionanoparticles may also lead to long-time stabilization of sensor molecules upon repeated uses and has the potential to increase sensor performance substantially, compared to conventional layouts. This has been demonstrated in different proof-of-concept biosensor devices. Therefore, richly available plant viral particles, non-pathogenic for animals or humans, might gain novel importance if applied in receptor layers of FEDs. These perspectives are explained and discussed with regard to future detection strategies for COVID-19 and related viral diseases. Y1 - 2020 U6 - http://dx.doi.org/10.3389/fpls.2020.598103 VL - 11 IS - Article 598103 SP - 1 EP - 14 PB - Frontiers CY - Lausanne ER - TY - JOUR A1 - Poghossian, Arshak A1 - Jablonski, Melanie A1 - Koch, Claudia A1 - Bronder, Thomas A1 - Rolka, David A1 - Wege, Christina A1 - Schöning, Michael Josef T1 - Field-effect biosensor using virus particles as scaffolds for enzyme immobilization JF - Biosensors and Bioelectronics N2 - A field-effect biosensor employing tobacco mosaic virus (TMV) particles as scaffolds for enzyme immobilization is presented. Nanotubular TMV scaffolds allow a dense immobilization of precisely positioned enzymes with retained activity. To demonstrate feasibility of this new strategy, a penicillin sensor has been developed by coupling a penicillinase with virus particles as a model system. The developed field-effect penicillin biosensor consists of an Al-p-Si-SiO₂-Ta₂O₅-TMV structure and has been electrochemically characterized in buffer solutions containing different concentrations of penicillin G. In addition, the morphology of the biosensor surface with virus particles was characterized by scanning electron microscopy and atomic force microscopy methods. The sensors possessed a high penicillin sensitivity of ~ 92 mV/dec in a nearly-linear range from 0.1 mM to 10 mM, and a low detection limit of about 50 µM. The long-term stability of the penicillin biosensor was periodically tested over a time period of about one year without any significant loss of sensitivity. The biosensor has also been successfully applied for penicillin detection in bovine milk samples. Y1 - 2018 U6 - http://dx.doi.org/10.1016/j.bios.2018.03.036 SN - 0956-5663 VL - 110 SP - 168 EP - 174 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Ingebrandt, S. A1 - Yeung, C.-K. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Microsensors based on ion-sensitive field-effect transistors for biomedical applications JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 1036 EP - 1037 ER - TY - CHAP A1 - Poghossian, Arshak A1 - Ingebrandt, S. A1 - Platen, J. A1 - Schöning, Michael Josef T1 - Field-effect sensors with charged macromolecules – from micro towards nano aspects T2 - Biochemical Sensing Utilisation of Micro-and Nanotechnologies, Warschau, Nov. 2005 : Lecture Notes of the ICB Seminar / ed.: M. Mascini, W. Torbicz Y1 - 2006 SP - 74 EP - 81 PB - Polish Academy Sciences Press CY - Warsaw ER - TY - JOUR A1 - Poghossian, Arshak A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Field-effect devices for detecting cellular signals JF - Seminars in Cell & Developmental Biology. 20 (2009), H. 1 Y1 - 2009 SN - 1096-3634 SP - 41 EP - 48 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Ingebrandt, S. A1 - Abouzar, Maryam H. A1 - Schöning, Michael Josef T1 - Label-free detection of charged macromolecules by using a field-effect-based sensor platform: Experiments and possible mechanisms of signal generation JF - Applied Physics A: Materials Science & Processing. 87 (2007), H. 3 Y1 - 2007 SN - 0947-8396 N1 - Special Issue “From Surface Science to Nanoscale Devices” SP - 517 EP - 524 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Geissler, Hanno A1 - Schöning, Michael Josef T1 - Rapid methods and sensors for milk quality monitoring and spoilage detection JF - Biosensors and Bioelectronics Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.bios.2019.04.040 SN - 0956-5663 VL - 140 IS - Article 111272 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Cherstvy, A. A1 - Schöning, Michael Josef T1 - Possibilities and limitations of label-free detection of DNA hybridization with field-effect based devices JF - Digest of technical papers : September 12 - 15, 2004, Rome, Italy, Pontificia Universitas Sancto Thoma Aquinate in Urbe / [conference chairperson: C. Di Natale]. Y1 - 2004 SN - 88-7621-282-5 N1 - Eurosensors ; (18, 2004, Roma) SP - 173 EP - 176 CY - Roma ER - TY - JOUR A1 - Poghossian, Arshak A1 - Cherstvy, A. A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Possibilities and limitations of label-free detection of DNA hybridization with field-effect-based devices JF - Sensors and Actuators B. 111-112 (2005) Y1 - 2005 SN - 0925-4005 N1 - Eurosensors XVIII 2004 — The 18th European Conference on Solid-State Transducers SP - 470 EP - 480 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Mayer, Dirk A1 - Schöning, Michael Josef T1 - Gating capacitive field-effect sensors by the charge of nanoparticle/molecule hybrids JF - Nanoscale Y1 - 2015 U6 - http://dx.doi.org/10.1039/C4NR05987E SN - 2040-3372 (E-Journal); 2040-3364 (Print) SP - 1023 EP - 1031 PB - Royal Society of Chemistry (RSC) CY - Cambridge ER - TY - CHAP A1 - Poghossian, Arshak A1 - Bronder, Thomas A1 - Wu, Chunsheng A1 - Schöning, Michael Josef T1 - Label-free sensing of biomolecules by their intrinsic molecular charge using field-effect devices T2 - Semiconductor Micro- and Nanoelectonics : Proceedings of the tenth international conference, Yerevan, Armenia, September 11-13 Y1 - 2015 SN - 978-5-8084-1991-9 SP - 61 EP - 63 ER - TY - CHAP A1 - Poghossian, Arshak A1 - Bronder, Thomas A1 - Scheja, S. A1 - Wu, Chunsheng A1 - Metzger-Boddien, C. A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Label-free Electrostatic Detection of DNA Amplification by PCR Using Capacitive Field-effect Devices T2 - Procedia Engineering N2 - A capacitive field-effect EIS (electrolyte-insulator-semiconductor) sensor modified with a positively charged weak polyelectrolyte of poly(allylamine hydrochloride) (PAH)/single-stranded probe DNA (ssDNA) bilayer has been used for a label-free electrostatic detection of pathogen-specific DNA amplification via polymerase chain reaction (PCR). The sensor is able to distinguish between positive and negative PCR solutions, to detect the existence of target DNA amplicons in PCR samples and thus, can be used as tool for a quick verification of DNA amplification and the successful PCR process. Y1 - 2016 U6 - http://dx.doi.org/10.1016/j.proeng.2016.11.512 SN - 1877-7058 N1 - Proceedings of the 30th anniversary Eurosensors Conference – Eurosensors 2016, 4-7. Sepember 2016, Budapest, Hungary VL - Vol. 168 SP - 514 EP - 517 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Poghossian, Arshak A1 - Berndsen, Lars A1 - Schöning, Michael Josef T1 - Chemical sensor as physical sensor: ISFET-based flowvelocity, flow-direction and diffusion-coefficient sensor JF - Sensors and Actuators B. 95 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 384 EP - 390 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Berndsen, Lars A1 - Lüth, Hans A1 - Schöning, Michael Josef T1 - Novel concepts for flow-rate and flow-direction determination by means of pH-sensitive ISFETs JF - Proceedings of SPIE. 4560 (2001) Y1 - 2001 SP - 19 EP - 27 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Berndsen, L. A1 - Schöning, Michael Josef T1 - Chemical sensor as a physical sensor: ISFET-based flowvelocity, flow-direction and diffusion-coefficient sensor JF - Book of abstracts / ed. by J. Saneistr. Y1 - 2002 SN - 80-01-02576-4 N1 - Eurosensors ; (16, 2002, Praha) SP - 649 EP - 652 PB - Czech Technical University, Faculty of Electrical Engineering, Department of Measurement CY - Prague ER - TY - JOUR A1 - Poghossian, Arshak A1 - Berndsen, L. A1 - Schultze, J. W. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - „High order“ hybrid sensor module based on an identical transducer principle JF - Chemical and biological sensors and analytical methods : proceedings of the international symposium / Sensor, Physical Electrochemistry, and Organic and Biological Electrochemistry Divisions. Ed.: M. Butler Y1 - 2001 SN - 1-56677-351-2 N1 - International Symposium: Chemical and Biological Sensors and Analytical Methods ; (2 : 2001.) SP - 143 EP - 152 PB - Electrochemical Society CY - Pennington, NJ ER - TY - JOUR A1 - Poghossian, Arshak A1 - Baade, A. A1 - Emons, H. A1 - Schöning, Michael Josef T1 - Application of ISFET for pH measurements in rain droplets JF - Sensors and Actuators B. 76 (2001), H. 1-3 Y1 - 2001 SN - 0925-4005 SP - 634 EP - 638 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Schöning, Michael Josef T1 - Capacitance–voltage and impedance characteristics of field-effect EIS sensors functionalised with polyelectrolyte multilayers JF - IRBM. 29 (2008), H. 2-3 Y1 - 2008 SN - 1959-0318 SP - 149 EP - 154 ER - TY - CHAP A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Schöning, Michael Josef ED - Abdelghani, Adnane ED - Schöning, Michael Josef T1 - (Bio-­)chemical sensor array based on nanoplate SOI capacitors T2 - Nanoscale Science and Technology (NS&T´12) : Proceedings Book Humboldt Kolleg ; Tunisia, 17-19 March, 2012 Y1 - 2012 SP - 31 EP - 31 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Sakkari, M. A1 - Kassab, T. A1 - Han, Y. A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Field-effect sensors for monitoring the layer-by-layer adsorption of charged macromolecules JF - Sensors and Actuators B: Chemical. 118 (2006), H. 1-2 Y1 - 2006 SN - 0925-4005 N1 - Eurosensors XIX - Eurosensors XIX - The 19th European Conference on Solid-State Transducers SP - 163 EP - 170 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Razavi, A. A1 - Bäcker, Matthias A1 - Bijnens, N. A1 - Williams, O. A. A1 - Haenen, K. A1 - Moritz, W. A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Nanocrystalline-diamond thin films with high pH and penicillin sensitivity prepared on a capacitive Si–SiO2 structure JF - Electrochimica Acta. 54 (2009), H. 25 Y1 - 2009 SN - 0013-4686 SP - 5981 EP - 5985 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Christiaens, P. A1 - Williams, O. A. A1 - Haenen, K. A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Sensing charged macromolecules with nanocrystalline diamond-based field-effect capacitive sensors JF - Journal of Contemporary Physics. 43 (2008), H. 2 Y1 - 2008 SN - 1934-9378 N1 - Armenian Academy of Sciences SP - 77 EP - 81 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Christiaens, P. A1 - Williams, O. A. A1 - Haenen, K. A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Nanocrystalline diamond-based field-effect (bio-)chemical sensor JF - 8. Dresdner Sensor-Symposium : Sensoren für Umwelt, Klima und Sicherheit, Biosensoren und Biosysteme, Sensoren und Sensorsysteme für die Prozesstechnik, Trends in der Sensortechnik, Materialentwicklung für die Sensorik; 8. Dresdner Sensor-Symposium, 10. - 12. Dezember 2007, Dresden / Gerald Gerlach ... (Hg.) Y1 - 2007 SN - 978-3-940046-45-1 N1 - Dresdner Sensor-Symposium <8, 2007, Dresden> ; Dresdner Beiträge zur Sensorik ; 29 SP - 191 EP - 194 PB - TUDpress, Verl. der Wissenschaften CY - Dresden ER - TY - JOUR A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Amberger, F. A1 - Mayer, D. A1 - Han, Y. A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Field-effect sensors with charged macromolecules: Characterisation by capacitance–voltage, constant-capacitance, impedance spectroscopy and atomic-force microscopy methods JF - Biosensors and Bioelectronics. 22 (2007), H. 9-10 Y1 - 2007 SN - 0956-5663 N1 - Selected Papers from the Ninth World Congress On Biosensors. Toronto, Canada 10 - 12 May 2006, Alice X. J . Tang SP - 2100 EP - 2107 ER - TY - CHAP A1 - Platen, Johannes A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Microstructured Nanostructures – nanostructuring by means of conventional photolithography and layer-expansion technique N2 - A new and simple method for nanostructuring using conventional photolithography and layer expansion or pattern-size reduction technique is presented, which can further be applied for the fabrication of different nanostructures and nano-devices. The method is based on the conversion of a photolithographically patterned metal layer to a metal-oxide mask with improved pattern-size resolution using thermal oxidation. With this technique, the pattern size can be scaled down to several nanometer dimensions. The proposed method is experimentally demonstrated by preparing nanostructures with different configurations and layouts, like circles, rectangles, trapezoids, “fluidic-channel”-, “cantilever”- and meander-type structures. KW - Biosensor KW - Nanostructuring KW - layer expansion KW - pattern-size reduction KW - self-aligned patterning Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1477 ER - TY - JOUR A1 - Pita, Marcos A1 - Krämer, Melina A1 - Zouh, Jian A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Fernandez, Victor M. A1 - Katz, Evgeny T1 - Optoelectronic Properties of Nanostructured Ensembles Controlled by Biomolecular Logic Systems JF - ACS Nano. 10 (2008), H. 2 Y1 - 2008 SN - 1936-086X SP - 2160 EP - 2166 ER - TY - JOUR A1 - Pilas, Johanna A1 - Yazici, Yasemen A1 - Selmer, Thorsten A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Optimization of an amperometric biosensor array for simultaneous measurement of ethanol, formate, d- and l-lactate JF - Electrochimica Acta N2 - The immobilization of NAD+-dependent dehydrogenases, in combination with a diaphorase, enables the facile development of multiparametric sensing devices. In this work, an amperometric biosensor array for simultaneous determination of ethanol, formate, d- and l-lactate is presented. Enzyme immobilization on platinum thin-film electrodes was realized by chemical cross-linking with glutaraldehyde. The optimization of the sensor performance was investigated with regard to enzyme loading, glutaraldehyde concentration, pH, cofactor concentration and temperature. Under optimal working conditions (potassium phosphate buffer with pH 7.5, 2.5 mmol L-1 NAD+, 2.0 mmol L-1 ferricyanide, 25 °C and 0.4% glutaraldehyde) the linear working range and sensitivity of the four sensor elements was improved. Simultaneous and cross-talk free measurements of four different metabolic parameters were performed successfully. The reliable analytical performance of the biosensor array was demonstrated by application in a clarified sample of inoculum sludge. Thereby, a promising approach for on-site monitoring of fermentation processes is provided. KW - Simultaneous determination KW - Enzymatic biosensor KW - Diaphorase KW - Dehydrogenase Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.electacta.2017.07.119 SN - 0013-4686 VL - 251 SP - 256 EP - 262 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Pilas, Johanna A1 - Yazici, Y. A1 - Selmer, Thorsten A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Application of a portable multi-analyte biosensor for organic acid determination in silage JF - Sensors N2 - Multi-analyte biosensors may offer the opportunity to perform cost-effective and rapid analysis with reduced sample volume, as compared to electrochemical biosensing of each analyte individually. This work describes the development of an enzyme-based biosensor system for multi-parametric determination of four different organic acids. The biosensor array comprises five working electrodes for simultaneous sensing of ethanol, formate, d-lactate, and l-lactate, and an integrated counter electrode. Storage stability of the biosensor was evaluated under different conditions (stored at +4 °C in buffer solution and dry at −21 °C, +4 °C, and room temperature) over a period of 140 days. After repeated and regular application, the individual sensing electrodes exhibited the best stability when stored at −21 °C. Furthermore, measurements in silage samples (maize and sugarcane silage) were conducted with the portable biosensor system. Comparison with a conventional photometric technique demonstrated successful employment for rapid monitoring of complex media. Y1 - 2018 U6 - http://dx.doi.org/10.3390/s18051470 SN - 1424-8220 VL - 18 IS - 5 PB - MDPI CY - Basel ER - TY - JOUR A1 - Pilas, Johanna A1 - Selmer, Thorsten A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Screen-printed carbon electrodes modified with graphene oxide for the design of a reagent-free NAD+-dependent biosensor array JF - Analytical Chemistry Y1 - 2019 U6 - http://dx.doi.org/10.1021/acs.analchem.9b04481 VL - 91 IS - 23 SP - 15293 EP - 15299 PB - ACS Publications CY - Washington ER - TY - JOUR A1 - Pilas, Johanna A1 - Mariano, K. A1 - Keusgen, M. A1 - Selmer, Thorsten A1 - Schöning, Michael Josef T1 - Optimization of an Enzyme-based Multi-parameter Biosensor for Monitoring Biogas Processes JF - Procedia Engineering Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.proeng.2015.08.702 SN - 1877-7058 N1 - Part of special issue "Eurosensors 2015" VL - 120 SP - 532 EP - 535 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Pilas, Johanna A1 - Iken, Heiko A1 - Selmer, Thorsten A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Development of a multi‐parameter sensor chip for the simultaneous detection of organic compounds in biogas processes JF - Physica status solidi (a) N2 - An enzyme-based multi-parameter biosensor is developed for monitoring the concentration of formate, d-lactate, and l-lactate in biological samples. The sensor is based on the specific dehydrogenation by an oxidized β-nicotinamide adenine dinucleotide (NAD+)-dependent dehydrogenase (formate dehydrogenase, d-lactic dehydrogenase, and l-lactic dehydrogenase, respectively) in combination with a diaphorase from Clostridium kluyveri (EC 1.8.1.4). The enzymes are immobilized on a platinum working electrode by cross-linking with glutaraldehyde (GA). The principle of the determination scheme in case of l-lactate is as follows: l-lactic dehydrogenase (l-LDH) converts l-lactate into pyruvate by reaction with NAD+. In the presence of hexacyanoferrate(III), the resulting reduced β-nicotinamide adenine dinucleotide (NADH) is then regenerated enzymatically by diaphorase. The electrochemical detection is based on the current generated by oxidation of hexacyanoferrate(II) at an applied potential of +0.3 V vs. an Ag/AgCl reference electrode. The biosensor will be electrochemically characterized in terms of linear working range and sensitivity. Additionally, the successful practical application of the sensor is demonstrated in an extract from maize silage. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431894 SN - 1862-6319 VL - 212 IS - 6 SP - 1306 EP - 1312 PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Pijanowska, Dorota G. A1 - Remiszewska, Elzbieta A1 - Pederzolli, Cecilia A1 - Lunelli, Lorenzo A1 - Vendano, Michele A1 - Canteri, Roberto A1 - Dudzinski, Konrad A1 - Kruk, Jerzy A1 - Torbicz, Wladyslaw T1 - Surface modification for microreactor fabrication N2 - In this paper, methods of surface modification of different supports, i.e. glass and polymeric beads for enzyme immobilisation are described. The developed method of enzyme immobilisation is based on Schiff’s base formation between the amino groups on the enzyme surface and the aldehyde groups on the chemically modified surface of the supports. The surface of silicon modified by APTS and GOPS with immobilised enzyme was characterised by atomic force microscopy (AFM), time-of-flight secondary ion mass spectroscopy (ToF-SIMS) and infrared spectroscopy (FTIR). The supports with immobilised enzyme (urease) were also tested in combination with microreactors fabricated in silicon and Perspex, operating in a flow-through system. For microreactors filled with urease immobilised on glass beads (Sigma) and on polymeric beads (PAN), a very high and stable signal (pH change) was obtained. The developed method of urease immobilisation can be stated to be very effective. KW - Biosensor KW - Microreactors KW - surface modification KW - enzyme immobilisation KW - lab-on-a-chip Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1480 ER - TY - CHAP A1 - Pijanowska, Dorota G. A1 - Remiszewska, Elzbieta T1 - pH-based detection of phenylalnine by potentiometric and colorimetric methods N2 - In this paper, methods of sample preparation for potentiometric measurement of phenylalanine are presented. Basing on the spectrophotometric measurements of phenylalanine, the concentrations of reagents of the enzymatic reaction (10 mM L-Phe, 0,4 mM NAD+, 2U L-PheDH) were determined. Then, the absorption spectrum of the reaction product, NADH, was monitored (maximum peak at 340 nm). The results obtained by the spectrophotometric method were compared with the results obtained by the colourimetry, using pH indicators. The above-mentioned two methods will be used as references for potentiometric measurements of phenylalanine concentration. KW - Biosensor KW - Phenylalanine determination KW - enzymatic methods KW - pH-based biosensing Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1536 ER - TY - JOUR A1 - Pieronek, Lukas A1 - Kleefeld, Andreas T1 - On trajectories of complex-valued interior transmission eigenvalues JF - Inverse problems and imaging : IPI N2 - This paper investigates the interior transmission problem for homogeneous media via eigenvalue trajectories parameterized by the magnitude of the refractive index. In the case that the scatterer is the unit disk, we prove that there is a one-to-one correspondence between complex-valued interior transmission eigenvalue trajectories and Dirichlet eigenvalues of the Laplacian which turn out to be exactly the trajectorial limit points as the refractive index tends to infinity. For general simply-connected scatterers in two or three dimensions, a corresponding relation is still open, but further theoretical results and numerical studies indicate a similar connection. KW - Interior transmission problem KW - Eigenvalue trajectories KW - Complex-valued eigenvalues Y1 - 2024 U6 - http://dx.doi.org/10.3934/ipi.2023041 SN - 1930-8337 (Print) SN - 1930-8345 (Online) VL - 18 IS - 2 SP - 480 EP - 516 PB - AIMS CY - Springfield, Mo ER - TY - JOUR A1 - Philipp, Mohr A1 - Efthimiou, Nikos A1 - Pagano, Fiammetta A1 - Kratochwil, Nicolaus A1 - Pizzichemi, Marco A1 - Tsoumpas, Charalampos A1 - Auffray, Etiennette A1 - Ziemons, Karl T1 - Image reconstruction analysis for positron emission tomography with heterostructured scintillators JF - IEEE Transactions on Radiation and Plasma Medical Sciences N2 - The concept of structure engineering has been proposed for exploring the next generation of radiation detectors with improved performance. A TOF-PET geometry with heterostructured scintillators with a pixel size of 3.0×3.1×15 mm3 was simulated using Monte Carlo. The heterostructures consisted of alternating layers of BGO as a dense material with high stopping power and plastic (EJ232) as a fast light emitter. The detector time resolution was calculated as a function of the deposited and shared energy in both materials on an event-by-event basis. While sensitivity was reduced to 32% for 100 μm thick plastic layers and 52% for 50 μm, the CTR distribution improved to 204±49 ps and 220±41 ps respectively, compared to 276 ps that we considered for bulk BGO. The complex distribution of timing resolutions was accounted for in the reconstruction. We divided the events into three groups based on their CTR and modeled them with different Gaussian TOF kernels. On a NEMA IQ phantom, the heterostructures had better contrast recovery in early iterations. On the other hand, BGO achieved a better contrast to noise ratio (CNR) after the 15th iteration due to the higher sensitivity. The developed simulation and reconstruction methods constitute new tools for evaluating different detector designs with complex time responses. KW - TOF PET KW - Heterostructure KW - Metascintillator KW - Multiple TOF kernels KW - Image Reconstruction Y1 - 2022 U6 - http://dx.doi.org/10.1109/TRPMS.2022.3208615 SN - 2469-7311 SN - 2469-7303 VL - 7 IS - 1 SP - 41 EP - 51 PB - IEEE CY - New York, NY ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Vu, Khoi Duc A1 - Tran, Thanh Ngoc A1 - Staat, Manfred T1 - A primal-dual algorithm for shakedown analysis of elastic-plastic bounded linearly kinematic hardening bodies Y1 - 2010 N1 - ECCM 2010, IV European Conference on Computational Mechanics, Paris, France, May 16-21, 2010. SP - 1 EP - 7 ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - An Upper Bound Algorithm for Limit and Shakedown Analysis of Bounded Linearly Kinematic Hardening Structures JF - Limit State of Materials and Structures : Direct Methods 2. Saxcé, Géry de (Hrsg.) Y1 - 2013 SN - 978-94-007-5424-9 SP - 71 EP - 87 PB - Springer CY - Dordrecht ER - TY - JOUR A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - FEM-based shakedown analysis of hardening structures JF - Asia Pacific journal on computational engineering N2 - This paper develops a new finite element method (FEM)-based upper bound algorithm for limit and shakedown analysis of hardening structures by a direct plasticity method. The hardening model is a simple two-surface model of plasticity with a fixed bounding surface. The initial yield surface can translate inside the bounding surface, and it is bounded by one of the two equivalent conditions: (1) it always stays inside the bounding surface or (2) its centre cannot move outside the back-stress surface. The algorithm gives an effective tool to analyze the problems with a very high number of degree of freedom. Our numerical results are very close to the analytical solutions and numerical solutions in literature. Y1 - 2014 U6 - http://dx.doi.org/10.1186/2196-1166-1-4 SN - 2196-1166 (E-Journal) IS - 1 SP - Article No. 4 PB - SpringerOpen CY - Berlin ER - TY - CHAP A1 - Pham, Phu Tinh A1 - Staat, Manfred T1 - A simplification for shakedown analysis of hardening structures T2 - Conference proceedings of the YIC GACM 2015 : 3rd ECCOMAS Young Investigators Conference and 6th GACM Colloquium on Computational Mechanics , Aachen , Germany, 20.07.2015 - 23.07.2015 / ed.: Stefanie Elgeti ; Jaan-Willem Simon Y1 - 2015 SP - 1 EP - 4 PB - RWTH Aachen University CY - Aachen ER - TY - CHAP A1 - Pham, Phu Tinh A1 - Nguyen, Thanh Ngoc A1 - Staat, Manfred T1 - FEM based shakedown analysis of hardening structures T2 - Proceedings International Conference on Advances in Computational Mechanics (ACOME) Y1 - 2012 N1 - International Conference on Advances in Computational Mechanics (ACOME), August 14-16, 2012, Ho Chi Minh City, Vietnam SP - 870 EP - 882 ER - TY - THES A1 - Pham, Phu Tinh T1 - Upper bound limit and shakedown analysis of elastic-plastic bounded linearly kinematic hardening structures Y1 - 2011 N1 - Aachen, Techn. Hochsch., Diss., 2011 PB - RWTH Aachen University CY - Aachen ER - TY - CHAP A1 - Peters, H. A1 - Ziemons, Karl A1 - Dammers, J. A1 - Müller-Veggian, Mattea ED - Nenonen, Jukka T1 - Continuous head motion detection during MEG measurement using head location coils T2 - Proceedings of the 12th International Conference on Biomagnetism : August 13 - 17, 2000, Helsinki University of Technology, Espoo, Finland Y1 - 2001 SN - 951-22-5401-8 N1 - Biomag <12, 2000, Espoo> ; Teknillinen Korkeakoulu ; International Conference on Biomagnetism <12, 2000, Espoo> PB - Helsinki Univ. of Technology, Laboratory of Biomedical Engineering CY - Espoo ER - TY - JOUR A1 - Pawelke, Siegfried A1 - Schmitt, W. A1 - Meissen, Th. T1 - Aachen 3D finger. 3D digitizer for application in dentistry / Schmitt, W. ; Pawelke, S. ; Meissen, Th. JF - Biomedizinische Technik. 35 (1990), H. 4 Y1 - 1990 SN - 0013-5585 SP - 69 EP - 71 ER - TY - JOUR A1 - Pawelke, Siegfried A1 - Butzer, Paul L. T1 - Semi-groups and resolvent operators JF - Archive for Rational Mechanics and Analysis KW - Resolvent Operator KW - Electromagnetism KW - Complex System KW - Neural Network KW - Nonlinear Dynamics Y1 - 1968 U6 - http://dx.doi.org/10.1007/BF00250941 SN - 0003-9527 VL - 30 IS - 2 SP - 127 EP - 147 PB - Springer CY - Berlin ER - TY - JOUR A1 - Pawelke, Siegfried T1 - Weak smoothness conditions for the uniform convergence of Fourier-Jacobi series JF - Functiones et Approximatio. Commentarii Mathematici. 9 (1980) Y1 - 1980 SN - 0208-6573 N1 - Zentralblatt MATH: http://www.emis.de/MATH-item?0471.42018 SP - 9 EP - 13 ER - TY - JOUR A1 - Pawelke, Siegfried T1 - Note on Jackson and Bernstein type approximation theorems in the case of approximation by algebraic polynomial in the spaces L and C JF - Studia Scientiarum Mathematicarum Hungarica. 36 (2000), H. 3-4 Y1 - 2000 SN - 0081-6906 SP - 353 EP - 358 ER - TY - JOUR A1 - Parl, C. A1 - Larue, H. A1 - Streun, M. A1 - Ziemons, Karl T1 - Double-side-readout technique for SiPM-matrices JF - 2010 IEEE Nuclear Science Symposium Conference Record (NSS/MIC) N2 - In our case the double-side-method is used to minimize the complexity of a matrix-readout. Here the number of channels is reduced to 2√N̅. It is also possible to benefit from the method in a single pixel readout system. One signal can be used to measure position and energy of the event, the other one can be applied to a fast trigger-circuit at the same time. In a next step we will investigate timing behavior and electrical crosstalk of the circuit. Y1 - 2011 SN - 1095-7863 SP - 1486 EP - 1487 PB - IEEE CY - New York ER -