TY - JOUR A1 - Bitz, Andreas A1 - Felder, Jorg A1 - Wittig, Tilmann T1 - Designing MRI Coils with Aid of Simulation JF - Microwaves & RF Y1 - 2013 SN - 0745-2993 VL - 52 IS - 7 SP - 56 PB - Penton CY - Cleveland, Ohio ER - TY - JOUR A1 - Bindal, Gaurav A1 - Sharma, Sparsh A1 - Janser, Frank A1 - Neu, Eugen T1 - Detailed analysis of variables affecting wing kinematics of bat flight JF - SAE International Journal of Aerospace Y1 - 2013 U6 - https://doi.org/10.4271/2013-01-9003 SN - 1946-3901 VL - 6 IS - 2 SP - 811 EP - 818 ER - TY - CHAP A1 - Rochefort, E. de A1 - Verver, M. A1 - Grunendahl, A. A1 - Mooi, H. A1 - Butenweg, Christoph T1 - Detailed modelling of the lumbar spine for investigation of low back pain T2 - Digital Human Modeling for Design and Engineering Symposium : Iowa City, Iowa June 14-16, 2005. (SAE technical papers series ; 2005-1-2716) Y1 - 2005 U6 - https://doi.org/10.4271/2005-01-2716 SN - 0096-736X SP - 1 EP - 11 PB - SAE International CY - Warrendale, Pa. ER - TY - JOUR A1 - Rochefort, E. de A1 - Verver, M. A1 - Grunendahl, A. A1 - Mooi, H. A1 - Butenweg, Christoph T1 - Detailed modelling of the lumbar spine for investigations of low back pain JF - SAE transactions : papers presented at Society and Section meetings / Society of Automotive Engineers Y1 - 2005 SN - 0096-736X VL - Volume 114 IS - Part 7 SP - 788 EP - 796 ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Fuchs, Katharina A1 - Dieringer, Matthias A. A1 - Özerdem, Celal A1 - Patel, Nishan A1 - Renz, Wolfgang A1 - Greiser, Andreas A1 - Elgeti, Thomas A1 - Niendorf, Thoralf T1 - Detailing the use of magnetohydrodynamic effects for synchronization of MRI with the cardiac cycle: A feasibility study JF - Journal of Magnetic Resonance Imaging N2 - Purpose: To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle. Materials and Methods: The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.05–7.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization. Results: The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs. Conclusion: This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364–372. © 2012 Wiley Periodicals, Inc. Y1 - 2012 U6 - https://doi.org/10.1002/jmri.23634 SN - 1522-2586 VL - 36 IS - 2 SP - 364 EP - 372 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Poghossian, Arshak A1 - Schöning, Michael Josef T1 - Detecting Both Physical and (Bio-)Chemical Parameters by Means of ISFET Devices JF - Electroanalysis. 16 (2004), H. 22 Y1 - 2004 SN - 1040-0397 SP - 1863 EP - 1872 ER - TY - JOUR A1 - Allefeld, Carsten A1 - Bialonski, Stephan T1 - Detecting synchronization clusters in multivariate time series via coarse-graining of Markov chains JF - Physical Review E Y1 - 2007 U6 - https://doi.org/10.1103/PhysRevE.76.066207 SN - 2470-0053 VL - 76 IS - 6 SP - 066207 ER - TY - JOUR A1 - Schmich, Peter A1 - Ederer, Hanns J. A1 - Ebert, Klaus H. T1 - Detection and identification of free radicals in hydrocarbon pyrolysis by an iodine trapping method JF - Industrial & Engineering Chemistry Research. 31 (1992), H. 1 Y1 - 1992 SN - 1520-5045 SP - 29 EP - 37 ER - TY - JOUR A1 - Welden, Melanie A1 - Severins, Robin A1 - Poghossian, Arshak A1 - Wege, Christina A1 - Bongaerts, Johannes A1 - Siegert, Petra A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Detection of acetoin and diacetyl by a tobacco mosaic virus-assisted field-effect biosensor JF - Chemosensors N2 - Acetoin and diacetyl have a major impact on the flavor of alcoholic beverages such as wine or beer. Therefore, their measurement is important during the fermentation process. Until now, gas chromatographic techniques have typically been applied; however, these require expensive laboratory equipment and trained staff, and do not allow for online monitoring. In this work, a capacitive electrolyte–insulator–semiconductor sensor modified with tobacco mosaic virus (TMV) particles as enzyme nanocarriers for the detection of acetoin and diacetyl is presented. The enzyme acetoin reductase from Alkalihalobacillus clausii DSM 8716ᵀ is immobilized via biotin–streptavidin affinity, binding to the surface of the TMV particles. The TMV-assisted biosensor is electrochemically characterized by means of leakage–current, capacitance–voltage, and constant capacitance measurements. In this paper, the novel biosensor is studied regarding its sensitivity and long-term stability in buffer solution. Moreover, the TMV-assisted capacitive field-effect sensor is applied for the detection of diacetyl for the first time. The measurement of acetoin and diacetyl with the same sensor setup is demonstrated. Finally, the successive detection of acetoin and diacetyl in buffer and in diluted beer is studied by tuning the sensitivity of the biosensor using the pH value of the measurement solution. Y1 - 2022 U6 - https://doi.org/10.3390/chemosensors10060218 SN - 2227-9040 N1 - This article belongs to the Special Issue "Nanostructured Devices for Biochemical Sensing" VL - 10 IS - 6 PB - MDPI CY - Basel ER - TY - CHAP A1 - Molinnus, Denise A1 - Hardt, Gabriel A1 - Käver, Larissa A1 - Willenberg, Holger S. A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Detection of Adrenaline Based on Bioelectrocatalytical System to Support Tumor Diagnostic Technology T2 - MDPI Proceedings Y1 - 2017 U6 - https://doi.org/10.3390/proceedings1040506 ER - TY - JOUR A1 - Molinnus, Denise A1 - Bäcker, Matthias A1 - Siegert, Petra A1 - Willenberg, H. A1 - Poghossian, Arshak A1 - Keusgen, M. A1 - Schöning, Michael Josef T1 - Detection of Adrenaline Based on Substrate Recycling Amplification JF - Procedia Engineering N2 - An amperometric enzyme biosensor has been applied for the detection of adrenaline. The adrenaline biosensor has been prepared by modification of an oxygen electrode with the enzyme laccase that operates at a broad pH range between pH 3.5 to pH 8. The enzyme molecules were immobilized via cross-linking with glutaraldehyde. The sensitivity of the developed adrenaline biosensor in different pH buffer solutions has been studied. Y1 - 2015 U6 - https://doi.org/10.1016/j.proeng.2015.08.708 SN - 1877-7058 N1 - Eurosensors 2015 VL - 120 SP - 540 EP - 543 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Molinnus, Denise A1 - Hardt, Gabriel A1 - Siegert, Petra A1 - Willenberg, Holger S. A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Detection of Adrenaline in Blood Plasma as Biomarker for Adrenal Venous Sampling JF - Electroanalysis N2 - An amperometric bi-enzyme biosensor based on substrate recycling principle for the amplification of the sensor signal has been developed for the detection of adrenaline in blood. Adrenaline can be used as biomarker verifying successful adrenal venous sampling procedure. The adrenaline biosensor has been realized via modification of a galvanic oxygen sensor with a bi-enzyme membrane combining a genetically modified laccase and a pyrroloquinoline quinone-dependent glucose dehydrogenase. The measurement conditions such as pH value and temperature were optimized to enhance the sensor performance. A high sensitivity and a low detection limit of about 0.5–1 nM adrenaline have been achieved in phosphate buffer at pH 7.4, relevant for measurements in blood samples. The sensitivity of the biosensor to other catecholamines such as noradrenaline, dopamine and dobutamine has been studied. Finally, the sensor has been successfully applied for the detection of adrenaline in human blood plasma. Y1 - 2018 U6 - https://doi.org/10.1002/elan.201800026 SN - 1521-4109 VL - 30 IS - 5 SP - 937 EP - 942 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Poghossian, Arshak T1 - Detection of charged macromolecules by means of field-effect devices (FEDs): possibilities and limitations JF - Electrochemical sensors, biosensors and their biomedical applications / ed. by Xueji Zhang ... Y1 - 2008 SN - 978-0-12-373738-0 SP - 187 EP - 212 PB - Elsevier Acad. Press CY - Amsterdam ER - TY - JOUR A1 - Herber, R. A1 - Ernst, S. A1 - Buß, G. A1 - Schöning, Michael Josef A1 - Baltruschat, H. T1 - Detection of hydrocarbons in air and water by adsorption on Pt electrodes using continuous impedance measurements JF - Proceedings of the Symposium on New Directions in Electroanalytical Chemistry II : [held at the 195th Meeting of the Electrochemical Society in Seattle, Washington on May 3 and 4, 1999] / Physical Electrochemistry, Sensor, and Organic and Biological Electrochemistry Divisions. Ed.: J. Leddy, P. Vanysek, M.D. Porter Y1 - 1999 SN - 1-56677-227-3 N1 - Symposium on New Directions in Electroanalytical Chemistry ; (2, 1999, Seattle, Wash.) SP - 168 EP - 177 PB - Electrochemical Society CY - Pennington, NJ ER - TY - JOUR A1 - Oberländer, Jan A1 - Kirchner, Patrick A1 - Boyen, Hans-Gerd A1 - Schöning, Michael Josef T1 - Detection of hydrogen peroxide vapor by use of manganese(IV) oxide as catalyst for calorimetric gas sensors JF - Physica status solidi A: Applications and materials science N2 - In this work, the catalyst manganese(IV) oxide (MnO2), of calorimetric gas sensors (to monitor the sterilization agent vaporized hydrogen peroxide) has been investigated in more detail. Chemical analyses by means of X-ray-induced photoelectron spectroscopy have been performed to unravel the surface chemistry prior and after exposure to hydrogen peroxide vapor at elevated temperature, as applied in the sterilization processes of beverage cartons. The surface characterization reveals a change in oxidation states of the metal oxide catalyst after exposure to hydrogen peroxide. Additionally, a cleaning effect of the catalyst, which itself is attached to the sensor surface by means of a polymer interlayer, could be observed. Y1 - 2014 U6 - https://doi.org/10.1002/pssa.201330359 SN - 1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print) VL - 211 IS - 6 SP - 1372 EP - 1376 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Kassab, T. A1 - Han, Y. A1 - Poghossian, Arshak A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Detection of layerby-layer adsorbed polyelectrolytes by means of field-effect based capacitive EIS structures JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 1034 EP - 1035 ER - TY - JOUR A1 - Emons, H. A1 - Hüllenkremer, B. A1 - Schöning, Michael Josef T1 - Detection of metal ions in aqueous solutions by voltohmmetry JF - Fresenius' Journal of Analytical Chemistry. 369 (2001), H. 1 Y1 - 2001 SN - 0937-0633 SP - 42 EP - 46 ER - TY - JOUR A1 - Bronder, Thomas A1 - Jessing, Max P. A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Detection of PCR-Amplified Tuberculosis DNA Fragments with Polyelectrolyte-Modified Field-Effect Sensors JF - Analytical Chemistry N2 - Field-effect-based electrolyte-insulator-semiconductor (EIS) sensors were modified with a bilayer of positively charged weak polyelectrolyte (poly(allylamine hydrochloride) (PAH)) and probe single-stranded DNA (ssDNA) and are used for the detection of complementary single-stranded target DNA (cDNA) in different test solutions. The sensing mechanism is based on the detection of the intrinsic molecular charge of target cDNA molecules after the hybridization event between cDNA and immobilized probe ssDNA. The test solutions contain synthetic cDNA oligonucleotides (with a sequence of tuberculosis mycobacteria genome) or PCR-amplified DNA (which origins from a template DNA strand that has been extracted from Mycobacterium avium paratuberculosis-spiked human sputum samples), respectively. Sensor responses up to 41 mV have been measured for the test solutions with DNA, while only small signals of ∼5 mV were detected for solutions without DNA. The lower detection limit of the EIS sensors was ∼0.3 nM, and the sensitivity was ∼7.2 mV/decade. Fluorescence experiments using SybrGreen I fluorescence dye support the electrochemical results. Y1 - 2018 U6 - https://doi.org/10.1021/acs.analchem.8b01807 SN - 0003-2700 VL - 90 IS - 12 SP - 7747 EP - 7753 PB - ACS Publications CY - Washington, DC ER - TY - CHAP A1 - Takenaga, Shoko A1 - Herrera, Cony F. A1 - Werner, Frederik A1 - Biselli, Manfred A1 - Schnitzler, Thomas A1 - Schöning, Michael Josef A1 - Öhlschläger, Peter A1 - Wagner, Torsten T1 - Detection of the metabolic activity of cells by differential measurements based on a single light-addressable potentiometric sensor chip T2 - 11. Dresdner Sensor-Symposium : 9.-11.12.2013 Y1 - 2013 SN - 978-3-9813484-5-3 SP - 63 EP - 67 ER - TY - CHAP A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Stütz, Evamaria A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Detection of toxic chromium species in water using cellbased sensor systems Y1 - 2012 SN - 978-3-9813484-2-2 U6 - https://doi.org/10.5162/IMCS2012/P2.1.14 SP - 1364 EP - 1367 ER - TY - JOUR A1 - Warmer, Johannes A1 - Wagner, Patrick A1 - Schöning, Michael Josef A1 - Kaul, Peter T1 - Detection of triacetone triperoxide using temperature cycled metal-oxide semiconductor gas sensors JF - Physica status solidi (a) Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201431882 SN - 1862-6319 VL - 212 IS - 6 SP - 1289 EP - 1298 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Hartmann, Axel A1 - Kallweit, Stephan A1 - Feldusen, Antje A1 - Schröder, Wolfgang T1 - Detection of upstream propagating sound waves at buffet flow using high-speed PIV BT - 16th International Symposium on Applications of Laser Techniques to Fluid Mechanics ; 9th to 12th July 2012 Lisbon, Portugal Y1 - 2012 N1 - Aerodynamisches Institut ; International Symposium on Applications of Laser Techniques to Fluid Mechanics <16, 2012, Lissabon> ER - TY - JOUR A1 - Schopp, Christoph A1 - Rohrbach, Felix A1 - Langer, Luc A1 - Heuermann, Holger T1 - Detection of welding wire length by active S11 measurement JF - IEEE Transactions on Plasma Science N2 - A novel method to determine the extruded length of a metallic wire for a directed energy deposition (DED) process using a microwave (MW) plasma jet with a straight-through wire feed is presented. The method is based on the relative comparison of the measured frequency response obtained by the large-signal scattering parameter (Hot-S) technique. In the practical working range, repeatability of less than 6% for a nonactive plasma and 9% for the active plasma state is found. Measurements are conducted with a focus on a simple solution to decrease the processing time and reduce the integration time of the process into the existing hardware. It is shown that monitoring a single frequency for magnitude and phase changes is sufficient to achieve good accuracy. A combination of different measurement values to determine the length is possible. The applicability to different diameter of the same material is shown as well as a contact detection of the wire and metallic substrate. KW - Circuit simulation KW - Hot S-parameter KW - Modeling KW - Plasma KW - Plasma diagnostics Y1 - 2024 U6 - https://doi.org/10.1109/TPS.2024.3356659 SN - 0093-3813 (Print) SN - 1939-9375 (Online) IS - Early Access SP - 1 EP - 6 PB - IEEE ER - TY - BOOK A1 - Gell, Sebastian T1 - Determinants of earnings forecast error, earnings forecast revision and earnings forecast accuracy N2 - ​Earnings forecasts are ubiquitous in today’s financial markets. They are essential indicators of future firm performance and a starting point for firm valuation. Extremely inaccurate and overoptimistic forecasts during the most recent financial crisis have raised serious doubts regarding the reliability of such forecasts. This thesis therefore investigates new determinants of forecast errors and accuracy. In addition, new determinants of forecast revisions are examined. More specifically, the thesis answers the following questions: 1) How do analyst incentives lead to forecast errors? 2) How do changes in analyst incentives lead to forecast revisions?, and 3) What factors drive differences in forecast accuracy? Y1 - 2012 SN - 978-3-8349-3936-4 SN - 978-3-8349-3937-1 U6 - https://doi.org/10.1007/978-3-8349-3937-1 N1 - Titel in der Buchreihe: Quantitatives Controlling PB - Springer Gabler CY - Wiesbaden ER - TY - JOUR A1 - Tippkötter, Nils A1 - Deterding, A. A1 - Ulber, Roland T1 - Determination of acetic acid in fermentation broth by gas-diffusion technique JF - Engineering in Life Sciences N2 - Due to the interfering effects of acetic acid in many fermentation processes, a gas-diffusion technique was developed for the online determination of acetic acid. The measurements were accomplished with a flow diffusion analysis (FDA) unit from the TRACE Analytics GmbH, Braunschweig, Germany. The diffusion analysis is based on the UV-absorbance of acetic acid at 205 nm. The measurement was achieved by the separation of an acceptor and a carrier stream (acidified fermentation broth) using a gas permeable polytetrafluoroethylene (PTFE) membrane, whereby broth constituents that would otherwise disturb the UV-measurement of acetic acid, are held back efficiently. Merely, the fermentation by-products, e.g. formic acid, is capable of diffusing through the membrane. While formic acid can disturb the measurement, carbon dioxide does not absorb at 205 nm. The method operates with time-dependent sample enrichment. During the analysis, a small volume of the acceptor stream is stopped for a defined time interval in the acceptor chamber. During this period, the gaseous acetic acid diffuses through the membrane and is enriched in the acceptor chamber. Subsequently after the enrichment, the acceptor stream flows through a UV-detector. The intensity of the signal is proportional to the acetic acid concentration. Online measurements in bioreactors via a sterile filtration probe have been accomplished. A linear calibration in the range of 0.5–5.0 g/L acetic acid with a relative standard deviation of <5 % was obtained. A sampling rate of 8 samples per hour was possible. The system was applied for the determination of acetic acid in E. coli fermentation broth. The instrument is easy to clean, very user-friendly and does not require any toxic or expensive reagents. Y1 - 2008 U6 - https://doi.org/10.1002/elsc.200820227 VL - 8 IS - 1, Special Issue: Technical Systems for the Use in Life Sciences SP - 62 EP - 67 ER - TY - JOUR A1 - Wagner, Torsten A1 - Kloock, Joachim P. A1 - Schöning, Michael Josef T1 - Determination of cadmium concentration and pH value in aqueous solutions by means of a handheld light-addressable potentiometric sensor (LAPS) device JF - Electrochemical sensor analysis / edited by S. Alegret ... Y1 - 2007 SN - 978-0-444-53133-9 N1 - Wilson & Wilson's comprehensive analytical chemistry ; 49 SP - e35 EP - e44 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Wahle, Michael T1 - Determination of flow induced nonlinear vibrations of prestressed heat exchanger tubes T2 - Advanced Course in Heat Exchangers : Theory and Practice ; ICHMT Symposium ; Dubrovnik, Croatia 1981. - (ICHMT digital library online ; 19) Y1 - 1983 SP - 339 EP - 353 PB - Begell House CY - Redding, Connecticut ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. A1 - Thielen, H. J. T1 - Determination of Particle Size Distributions by Means of an Electrostatic Classifier / Fißan, H. J.; Helsper, C. ; Thielen, H. J. JF - Journal of Aerosol Science. 14 (1983), H. 3 Y1 - 1983 SN - 0021-8502 SP - 354 EP - 357 ER - TY - JOUR A1 - Förster, Arnold A1 - Tillmann, K. A1 - Thust, M. T1 - Determination of segregation, elastic strain and thin-foil relaxation in InxGa-1-x As islands on GaAs(001) by high resolution transmission electron microscopy / K. Tillmann ; A. Thust ; M. Lentzen ... A. Förster ... JF - Philosophical magazine / Letters. 74 (1996), H. 5 Y1 - 1996 SN - 1362-3036 SP - 309 EP - 315 ER - TY - JOUR A1 - Helsper, Christoph A1 - Wiedensohler, A. A1 - Weise, W. A1 - Lütkemeier, E. T1 - Determination of the Bipolar Charge Equilibrium in Pure Gases / Wiedensohler, A. ; Weise, W. ; Helsper, C. ; Lütkemeier, E. JF - Aerosols : formation and reactivity ; proceedings of the second International Aerosol Conference, 22-26 Sept. 1986, Berlin (West) / Gesellschaft für Aerosolforschung (GAeF) ; American Association for Aerosol Research (AAAR) Y1 - 1986 N1 - International Aerosol Conference ; (2, 1986, Berlin (West)) SP - 383 EP - 386 PB - Pergamon Press CY - Oxford [u.a.] ER - TY - JOUR A1 - Maggakis-Kelemen, Christina A1 - Biselli, Manfred A1 - Artmann, Gerhard T1 - Determination of the elastic shear modulus of cultured human red blood cells JF - Biomedizinische Technik. 47 (2002), H. Suppl. 1 Pt. 1 Y1 - 2002 SN - 0013-5585 N1 - Druckausgabe unter 63 Z 471 vorhanden SP - 106 EP - 109 ER - TY - JOUR A1 - Werner, Frederik A1 - Krumbe, Christoph A1 - Schumacher, Katharina A1 - Groebel, Simone A1 - Spelthahn, Heiko A1 - Stellberg, Michael A1 - Wagner, Torsten A1 - Yoshinobu, Tatsuo A1 - Selmer, Thorsten A1 - Keusgen, Michael A1 - Baumann, Marcus A1 - Schöning, Michael Josef T1 - Determination of the extracellular acidification of Escherichia coli by a light-addressable potentiometric sensor JF - Physica status solidi (a) : applications and material science. 208 (2011), H. 6 Y1 - 2011 SN - 1862-6319 SP - 1340 EP - 1344 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Dantism, Shahriar A1 - Takenaga, Shoko A1 - Wagner, Patrick A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Determination of the extracellular acidification of Escherichia coli K12 with a multi-​chamber-​based LAPS system JF - Physica status solidi (a) N2 - On-line monitoring of the metabolic activity of microorganisms involved in intermediate stages of biogas production plays an important role to avoid undesirable “down times” during the biogas production. In order to control this process, an on-chip differential measuring system based on the light-addressable potentiometric sensor (LAPS) principle combined with a 3D-printed multi-chamber structure has been realized. As a test microorganism, Escherichia coli K12 (E. coli K12) were used for cell-based measurements. Multi-chamber structures were developed to determine the metabolic activity of E. coli K12 in suspension for a different number of cells, responding to the addition of a constant or variable amount of glucose concentrations, enabling differential and simultaneous measurements. Y1 - 2016 U6 - https://doi.org/10.1002/pssa.201533043 SN - 1862-6300 VL - 213 IS - 6 SP - 1479 EP - 1485 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Hasan, Istabrak A1 - Keil, Ludger A1 - Staat, Manfred A1 - Wahl, Gerhard A1 - Bourauel, Christoph T1 - Determination of the frictional coefficient of the implant-antler interface : experimental approach JF - Biomedical Engineering / Biomedizinische Technik N2 - The similar bone structure of reindeer antler to human bone permits studying the osseointegration of dental implants in the jawbone. As the friction is one of the major factors that have a significant influence on the initial stability of immediately loaded dental implants, it is essential to define the frictional coefficient of the implant-antler interface. In this study, the kinetic frictional forces at the implant-antler interface were measured experimentally using an optomechanical setup and a stepping motor controller under different axial loads and sliding velocities. The corresponding mean values of the static and kinetic frictional coefficients were within the range of 0.5–0.7 and 0.3–0.5, respectively. An increase in the frictional forces with increasing applied axial loads was registered. The measurements showed an evidence of a decrease in the magnitude of the frictional coefficient with increasing sliding velocity. The results of this study provide a considerable assessment to clarify the suitable frictional coefficient to be used in the finite element contact analysis of antler specimens. Y1 - 2012 SN - 1862-278X VL - 57 IS - 5 SP - 359 EP - 363 PB - De Gruyter CY - Berlin ER - TY - JOUR A1 - Arpshofen, Ingo A1 - Pool, M. J. A1 - Sommer, Ferdinand A1 - Gerling, Ulrich A1 - Predel, Bruno A1 - Schultheiss, Emil T1 - Determination of the integral mixing enthalpies in the Cu-Pd-Si liquid ternary alloy system at 1600 K JF - Zeitschrift für Metallkunde : international journal of materials research and advanced techniques. Bd. 74, H. 1 Y1 - 1983 SN - 0044-3093 ; 0179-4841 SP - 25 EP - 32 ER - TY - JOUR A1 - Scherer, Ulrich W. A1 - Türler, A. A1 - Gäggeler, H. W. A1 - Jost, D. T. T1 - Determination of the Partial Electron-Capture- and Spontaneous-Fission Half-Lives of 254No / A. Türler, H.W. Gäggeler, D.T. Jost, P. Armbruster, W. Brüchle, H. Folger, F.P. Heßberger, S. Hofmann, JF - Zeitschrift für Physik A Hadrons and Nuclei. 331 (1988), H. 3 Y1 - 1988 SN - 0939-7922 SP - 363 EP - 364 ER - TY - CHAP A1 - Tischbein, Franziska A1 - Kean, Kilian A1 - Vertgewall, Chris Martin A1 - Ulbig, Andreas A1 - Altherr, Lena T1 - Determination of the topology of low-voltage distribution grids using cluster methods T2 - 27th International Conference on Electricity Distribution (CIRED 2023) N2 - Due to the decarbonization of the energy sector, the electric distribution grids are undergoing a major transformation, which is expected to increase the load on the operating resources due to new electrical loads and distributed energy resources. Therefore, grid operators need to gradually move to active grid management in order to ensure safe and reliable grid operation. However, this requires knowledge of key grid variables, such as node voltages, which is why the mass integration of measurement technology (smart meters) is necessary. Another problem is the fact that a large part of the topology of the distribution grids is not sufficiently digitized and models are partly faulty, which means that active grid operation management today has to be carried out largely blindly. It is therefore part of current research to develop methods for determining unknown grid topologies based on measurement data. In this paper, different clustering algorithms are presented and their performance of topology detection of low voltage grids is compared. Furthermore, the influence of measurement uncertainties is investigated in the form of a sensitivity analysis. Y1 - 2023 SN - 978-1-83953-855-1 U6 - https://doi.org/10.1049/icp.2023.0478 N1 - 27th International Conference on Electricity Distribution (CIRED 2023), 12-15 June 2023, Rome, Italy. SP - 1 EP - 5 PB - IEEE ER - TY - JOUR A1 - Grap, Rolf Dietmar T1 - Determining manpower requirements in a spinning mill JF - Chemical fibers international : CFI ; fiber polymers, fibers, texturing, and spunbonds (2003) Y1 - 2003 SN - 0340-3343 SP - 455 EP - 458 ER - TY - JOUR A1 - Sousa, Marcos A. M. A1 - Siqueira, Jose R. Jr. A1 - Vercik, Andres A1 - Schöning, Michael Josef A1 - Oliveira, Osvaldo N. Jr. T1 - Determining the optimized layer-by-layer film architecture with dendrimer/carbon nanotubes for field-effect sensors JF - IEEE Sensors Journal N2 - The capacitive electrolyte–insulator–semiconductor (EIS) structure is a typical device based on a field-effect sensor platform. With a simple silicon-based structure, EIS have been useful for several sensing applications, especially with incorporation of nanostructured films to modulate the ionic transport and the flat-band potential. In this paper, we report on ion transport and changes in flat-band potential in EIS sensors made with layer-by-layer films containing poly(amidoamine) (PAMAM) dendrimer and single-walled carbon nanotubes (SWNTs) adsorbed on p-Si/SiO 2 /Ta 2 O 5 chips with an Al ohmic contact. The impedance spectra were fitted using an equivalent circuit model, from which we could determine parameters such as the double-layer capacitance. This capacitance decreased with the number of bilayers owing to space charge accumulated at the electrolyte–insulator interface, up to three PAMAM/SWNTs bilayers, after which it stabilized. The charge-transfer resistance was also minimum for three bilayers, thus indicating that this is the ideal architecture for an optimized EIS performance. The understanding of the influence of nanostructures and the fine control of operation parameters pave the way for optimizing the design and performance of new EIS sensors. Y1 - 2017 U6 - https://doi.org/10.1109/JSEN.2017.2653238 SN - 1558-1748 VL - 17 IS - 6 SP - 1735 EP - 1740 PB - IEEE CY - New York ER - TY - CHAP A1 - Schleupen, Josef A1 - Engemann, Heiko A1 - Bagheri, Mohsen A1 - Kallweit, Stephan A1 - Dahmann, Peter T1 - Developing a climbing maintenance robot for tower and rotor blade service of wind turbines T2 - Advances in Robot Design and Intelligent Control : Proceedings of the 25th Conference on Robotics in Alpe-Adria-Danube Region (RAAD16) Y1 - 2017 SN - 978-3-319-49058-8 U6 - https://doi.org/10.1007/978-3-319-49058-8_34 N1 - Advances in Robot Design and Intelligent Control ; Vol. 540 SP - 310 EP - 319 PB - Springer CY - Cham ER - TY - JOUR A1 - Pöttgen, Philipp A1 - Ederer, Thorsten A1 - Altherr, Lena A1 - Pelz, Peter F. T1 - Developing a control strategy for booster stations under uncertain load JF - Applied Mechanics and Materials N2 - Booster stations can fulfill a varying pressure demand with high energy-efficiency, because individual pumps can be deactivated at smaller loads. Although this is a seemingly simple approach, it is not easy to decide precisely when to activate or deactivate pumps. Contemporary activation controls derive the switching points from the current volume flow through the system. However, it is not measured directly for various reasons. Instead, the controller estimates the flow based on other system properties. This causes further uncertainty for the switching decision. In this paper, we present a method to find a robust, yet energy-efficient activation strategy. KW - Technical Operations Research (TOR) KW - Booster Station KW - Pump System KW - Discrete Optimization Y1 - 2015 SN - 1662-7482 U6 - https://doi.org/10.4028/www.scientific.net/AMM.807.241 N1 - Ebenfalls weltweit einsehbar unter: http://wl.fst.tu-darmstadt.de/wl/publications/paper_151123_SFB805_ ICUME_Developing_a_Control_Strategy_for_Booster_Stations_under_Uncertain_Load_poettgen_ederer_pelz_altherr.pdf VL - 807 IS - 807 SP - 241 EP - 246 PB - Trans Tech Publications CY - Bäch ER - TY - JOUR A1 - Küppers, Tobias A1 - Steffen, Victoria A1 - Hellmuth, Hendrik A1 - O'Connell, Timothy A1 - Bongaerts, Johannes A1 - Maurer, Karl-Heinz A1 - Wiechert, Wolfgang T1 - Developing a new production host from a blueprint: Bacillus pumilus as an industrial enzyme producer JF - Microbial cell factories Y1 - 2014 U6 - https://doi.org/10.1186/1475-2859-13-46 SN - 1475-2859 (E-Journal) VL - 13 SP - Article No. 46 PB - BioMed Central CY - London ER - TY - JOUR A1 - Bung, Daniel Bernhard T1 - Developing flow in skimming flow regime on embankment stepped spillways JF - Journal of hydraulic research Y1 - 2011 SN - 1814-2079 (E-Journal); 0022-1686 (Print) VL - Vol. 49 IS - Iss. 5 SP - 639 EP - 648 PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Aliazizi, Fereshteh A1 - Özsoylu, Dua A1 - Bakhshi Sichani, Soroush A1 - Khorshid, Mehran A1 - Glorieux, Christ A1 - Robbens, Johan A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Development and Calibration of a Microfluidic, Chip-Based Sensor System for Monitoring the Physical Properties of Water Samples in Aquacultures JF - Micromachines N2 - In this work, we present a compact, bifunctional chip-based sensor setup that measures the temperature and electrical conductivity of water samples, including specimens from rivers and channels, aquaculture, and the Atlantic Ocean. For conductivity measurements, we utilize the impedance amplitude recorded via interdigitated electrode structures at a single triggering frequency. The results are well in line with data obtained using a calibrated reference instrument. The new setup holds for conductivity values spanning almost two orders of magnitude (river versus ocean water) without the need for equivalent circuit modelling. Temperature measurements were performed in four-point geometry with an on-chip platinum RTD (resistance temperature detector) in the temperature range between 2 °C and 40 °C, showing no hysteresis effects between warming and cooling cycles. Although the meander was not shielded against the liquid, the temperature calibration provided equivalent results to low conductive Milli-Q and highly conductive ocean water. The sensor is therefore suitable for inline and online monitoring purposes in recirculating aquaculture systems. KW - chip-based sensor setup KW - aquaculture KW - microfluidics KW - impedance spectroscopy KW - thermometry KW - electrical conductivity of liquids Y1 - 2024 U6 - https://doi.org/10.3390/mi15060755 SN - 2072-666X N1 - This article belongs to the Special Issue "Multisensor Arrays" N1 - Corresponding author: Michael J. Schöning VL - 15 IS - 6 PB - MDPI CY - Basel ER - TY - JOUR A1 - Wagner, Torsten A1 - Werner, Frederik A1 - Miyamoto, Ko-Ichiro A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Development and characterisation of a compact light-addressable potentiometric sensor (LAPS) based on the digital light processing (DLP) technology for flexible chemical imaging JF - Sensors and Actuators B: Chemical N2 - Chemical imaging systems allow the visualisation of the distribution of chemical species on the sensor surface. This work represents a new flexible approach to read out light-addressable potentiometric sensors (LAPS) with the help of a digital light processing (DLP) set-up. The DLP, known well for video projectors, consists of a mirror-array MEMS device, which allows fast and flexible generation of light patterns. With the help of these light patterns, the sensor surface of the LAPS device can be addressed. The DLP approach has several advantages compared to conventional LAPS set-ups, e.g., the spot size and the shape of the light pointer can be changed easily and no mechanical movement is necessary, which reduces the size of the set-up and increases the stability and speed of the measurement. In addition, the modulation frequency and intensity of the light beam are important parameters of the LAPS set-up. Within this work, the authors will discuss two different ways of light modulation by the DLP set-up, investigate the influence of different modulation frequencies and different light intensities as well as demonstrate the scanning capabilities of the new set-up by pH mapping on the sensor surface. Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2010.12.003 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 34 EP - 39 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Molinnus, Denise A1 - Muschallik, Lukas A1 - Gonzalez, Laura Osorio A1 - Bongaerts, Johannes A1 - Wagner, Torsten A1 - Selmer, Thorsten A1 - Siegert, Petra A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Development and characterization of a field-effect biosensor for the detection of acetoin JF - Biosensors and Bioelectronics N2 - A capacitive electrolyte-insulator-semiconductor (EIS) field-effect biosensor for acetoin detection has been presented for the first time. The EIS sensor consists of a layer structure of Al/p-Si/SiO₂/Ta₂O₅/enzyme acetoin reductase. The enzyme, also referred to as butane-2,3-diol dehydrogenase from B. clausii DSM 8716T, has been recently characterized. The enzyme catalyzes the (R)-specific reduction of racemic acetoin to (R,R)- and meso-butane-2,3-diol, respectively. Two different enzyme immobilization strategies (cross-linking by using glutaraldehyde and adsorption) have been studied. Typical biosensor parameters such as optimal pH working range, sensitivity, hysteresis, linear concentration range and long-term stability have been examined by means of constant-capacitance (ConCap) mode measurements. Furthermore, preliminary experiments have been successfully carried out for the detection of acetoin in diluted white wine samples. Y1 - 2018 U6 - https://doi.org/10.1016/j.bios.2018.05.023 VL - 115 SP - 1 EP - 6 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Turek, Monika A1 - Ketterer, Lothar A1 - Claßen, Melanie A1 - Berndt, Heinz A1 - Elbers, Gereon A1 - Krüger, Peter A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Development and Electrochemical Investigations of an EIS-(Electrolyte-Insulator-Semiconductor) based Biosensor for Cyanide Detection JF - Sensors Y1 - 2007 SN - 1424-8220 VL - 7 IS - 8 SP - 1415 EP - 1426 ER - TY - JOUR A1 - Rietsch, Stefan H. G. A1 - Brunheim, Sascha A1 - Orzada, Stephan A1 - Voelker, Maximilian N. A1 - Maderwald, Stefan A1 - Bitz, Andreas A1 - Gratz, Marcel A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - Development and evaluation of a 16-channel receive-only RF coil to improve 7T ultra-high field body MRI with focus on the spine JF - Magnetic Resonance in Medicine Y1 - 2019 U6 - https://doi.org/10.1002/mrm.27731 SN - 1522-2594 IS - Early view PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Wolf, Martin R. A1 - Foltz, Christian A1 - Schlick, Christopher A1 - Luczak, Holger T1 - Development and evaluation of a groupware system to support chemical design processes / Wolf, Martin ; Foltz, Christian ; Schlick, Christopher ; Luczak, Holger JF - International Journal of Human-Computer Interaction . 14 (2002), H. 2 Y1 - 2002 SN - 1044-7318 SP - 181 EP - 198 PB - - ER - TY - JOUR A1 - Martin, Conrad A1 - Frauenrath, Tobias A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging JF - European Radiology N2 - Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur. KW - MRI KW - MR safety KW - Magneto alert sensor KW - High field MRI KW - Uktrahigh field MRI Y1 - 2011 U6 - https://doi.org/10.1007/s00330-011-2153-z SN - 1432-1084 VL - 21 SP - 2187 EP - 2192 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Krämer, Stefan A1 - Daab, Dominique Jonas A1 - Müller, Brigitte A1 - Wagner, Tobias A1 - Baader, Fabian A1 - Hessel, Joana A1 - Gdalewitsch, Georg A1 - Plescher, Engelbert A1 - Dachwald, Bernd A1 - Wahle, Michael A1 - Gierse, Andreas A1 - Vetter, Rudolf A1 - Pfützenreuter, Lysan T1 - Development and flight-testing of a system to isolate vibrations for microgravity experiments on sounding rockets JF - 21st ESA Symposium on Rocket and Balloon Research Y1 - 2013 SP - 1 EP - 8 ER - TY - CHAP A1 - Funke, Harald A1 - Börner, Sebastian A1 - Hendrick, P. A1 - Recker, E. A1 - Elsing, R. ED - DeLuca, Luigi T. T1 - Development and integration of a scalable low NOx combustion chamber for a hydrogen fuelled aero gas turbine T2 - Progress in Propulsion Physics. - Vol. 4 Y1 - 2013 SN - 978-2-7598-0876-2 U6 - https://doi.org/10.1051/eucass/201304357 N1 - 4th European Conference for Aero-Space Sciences : July 4 - 8, 2011, St Petersburg, Russia ; EUCASS <4, 2011, St. Petersburg> SP - 357 EP - 372 PB - EDP Sciences CY - [Les Ulis] ER - TY - GEN A1 - Schulze-Buxloh, Lina A1 - Groß, Rolf Fritz A1 - Cheng, Kevin Toni T1 - Development and manufacturing of an interactive three-dimensional phase diagram of carbon dioxide for teaching sessions in thermodynamics T2 - Proceedings of the International Conference The Future of Education 2020 Y1 - 2020 ER - TY - CHAP A1 - Vedral, Andreas A1 - Kruse, Thomas A1 - Wollert, Jörg T1 - Development and performance evaluation of an antenna diversity module for industrial communication based on IEEE 802.15.4 T2 - 12th IEEE International Conference on Emerging Technologies and Factory Automation : ETFA 2007 : proceedings : 25-28 Sept. 2007, Patras, Greece Y1 - 2007 SN - 1424408261 ; 9781424408269 U6 - https://doi.org/10.1109/EFTA.2007.4416769 SP - 177 EP - 186 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Enning, Manfred A1 - Jenayeh, I. A1 - Müller, C. A1 - Rake, Heinrich T1 - Development and realization of a manipulator for automatic decoupling of freight cars in marshalling yards / Jenayeh, I. ; Müller, C. ; Enning, Manfred ; Rake, Heinrich ; Peter, J. Y1 - 1997 N1 - World Congress on Railway Research, Florenz, 16.-19.11.1997, 1997 ER - TY - JOUR A1 - Funke, Harald A1 - Rönna, Uwe A1 - Robinson, A. E. T1 - Development and testing of a 10 kW diffusive micromix combustor for hydrogen-fuelled μ-scale gas turbines JF - Proceedings of ASME Turbo Expo 2008: Power for Land, Sea and Air ; GT2008 ; June 9-13, 2008, Berlin, Germany Y1 - 2008 N1 - GT2008-50418 SP - 1 EP - 8 PB - ASME CY - New York, NY ER - TY - CHAP A1 - Funke, Harald A1 - Beckmann, Nils A1 - Abanteriba, Sylvester T1 - Development and Testing of a FuelFlex Dry-Low-NOx Micromix Combustor for Industrial Gas Turbine Applications With Variable Hydrogen Methane Mixtures T2 - ASME Turbo Expo 2019: Turbomachinery Technical Conference and Exposition. June 17–21, 2019 Phoenix, Arizona, USA. Volume 4A: Combustion, Fuels, and Emissions Y1 - 2019 SN - 978-0-7918-5861-5 U6 - https://doi.org/10.1115/GT2019-90095 ER - TY - CHAP A1 - Funke, Harald A1 - Keinz, Jan A1 - Haj Ayed, A. A1 - Kazari, M. A1 - Kitajima, J. A1 - Horikawa, A. A1 - Okada, K. T1 - Development and Testing of a Low NOx Micromix Combustion Chamber for an Industrial Gas Turbine T2 - Proceedings of International Gas Turbine Congress 2015 Tokyo November 15-20, 2015, Tokyo, Japan Y1 - 2015 SN - 978-4-89111-008-6 N1 - IGTC15-0092 SP - 131 EP - 140 ER - TY - CHAP A1 - Anthrakidis, Anette A1 - Herrmann, Ulf A1 - Schorn, Christian A1 - Schwarzer, Klemens A1 - Wedding, Philipp A1 - Weis, Fabian T1 - Development and Testing of a Novel Method for the Determination of the Efficiency of Concentrating Solar Thermal Collectors T2 - Conference Proceedings Solar World Congress 2015, Daegu, Korea, 08 – 12 November 2015 Y1 - 2015 ER - TY - CHAP A1 - Schneider, Oliver A1 - Al Hakim, Taher A1 - Kayser, Peter A1 - Digel, Ilya ED - Erni, Daniel ED - Fischerauer, Alice ED - Himmel, Jörg ED - Seeger, Thomas ED - Thelen, Klaus T1 - Development and trials of a test chamber for ultrasound-assisted sampling of living cells from solid surfaces T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - https://doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 SP - 96 EP - 97 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Starke, Günther A1 - Drews, P. T1 - Development approaches for advanced control in automated arc welding Y1 - 1985 N1 - Konferenz-Einzelbericht: Automation and robotisation in welding and allied processes. International conference on automation and robotisation in welding and allied processes, Strasbourg, FR, 02.09.1985-03.09.1985 SP - 115 EP - 124 ER - TY - CHAP A1 - Buck, R. A1 - Wurmhöringer, K. A1 - Lehle, R. A1 - Pfahl, A. A1 - Göttsche, Joachim A1 - Meyr, T. T1 - Development of a 30m2 heliostat with hydraulic drive T2 - SolarPACES 2010 : the CSP Conference: electricity, fuels and clean water from concentrated solar energy ; 21 to 24 September 2010, Perpignan, France Y1 - 2010 SP - 74 EP - 75 PB - Soc. OSC CY - Saint Maur ER - TY - JOUR A1 - Seifarth, Volker A1 - Goßmann, Matthias A1 - Grosse, J. O. A1 - Becker, C. A1 - Heschel, I. A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Development of a Bioreactor to Culture Tissue Engineered Ureters Based on the Application of Tubular OPTIMAIX 3D Scaffolds JF - Urologia Internationalis Y1 - 2015 U6 - https://doi.org/10.1159/000368419 SN - 0042-1138 VL - 2015 IS - 95 SP - 106 EP - 113 PB - Karger CY - Basel ER - TY - JOUR A1 - Keusgen, M. A1 - Jünger, M. A1 - Krest, I. A1 - Schöning, Michael Josef T1 - Development of a biosensor specific for cysteine sulfoxides JF - Biosensors & Bioelectronics. 18 (2003), H. 5-6 Y1 - 2003 SN - 0956-5663 SP - 805 EP - 812 ER - TY - JOUR A1 - Iken, Heiko A1 - Bronder, Thomas A1 - Goretzki, Alexander A1 - Kriesel, Jana A1 - Ahlborn, Kristina A1 - Gerlach, Frank A1 - Vonau, Winfried A1 - Zander, Willi A1 - Schubert, Jürgen A1 - Schöning, Michael Josef T1 - Development of a Combined pH- and Redox-Sensitive Bi-Electrode Glass Thin-Film Sensor JF - physica status solidi a : applications and materials sciences Y1 - 2019 U6 - https://doi.org/10.1002/pssa.201900114 SN - 1862-6319 VL - 216 IS - 12 SP - 1 EP - 8 PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Schopen, Oliver A1 - Kemper, Hans A1 - Esch, Thomas T1 - Development of a comparison methodology and evaluation matrix for electrically driven compressors in ICE and FC T2 - Proceedings of the 1st UNITED – Southeast Asia Automotive Interest Group (SAIG) International Conference N2 - In addition to electromobility and alternative drive systems, a focus is set on electrically driven compressors (EDC), with a high potential for increasing the efficiency of internal combustion engines (ICE) and fuel cells [01]. The primary objective is to increase the ICE torque, provided independently of the ICE speed by compressing the intake air and consequently the ICE filling level supported by the compressor. For operation independent from the ICE speed, the EDC compressor is decoupled from the turbine by using an electric compressor motor (CM) instead of the turbine. ICE performances can be increased by the use of EDC where individual compressor parameters are adapted to the respective application area [02] [03]. This task contains great challenges, increased by demands with regard to pollutant reduction while maintaining constant performance and reduced fuel consumption. The FH-Aachen is equipped with an EDC test bench which enables EDC-investigations in various configurations and operating modes. Characteristic properties of different compressors can be determined, which build the basis for a comparison methodology. Subject of this project is the development of a comparison methodology for EDC with an associated evaluation method and a defined overall evaluation method. For the application of this comparison methodology, corresponding series of measurements are carried out on the EDC test bench using an appropriate test device. KW - electro mobility KW - fuel cell KW - internal combustion engine KW - electrically driven compressors Y1 - 2021 SN - 978-3-902103-94-9 N1 - 1st UNITED-SAIG International Conference, 21-22 APR 2021, Chulalongkorn University, Thailand SP - 45 EP - 46 PB - FH Joanneum CY - Graz ER - TY - JOUR A1 - Dünkelmann, Pascal A1 - Kolter-Jung, Doris A1 - Nitsche, Adam A1 - Demir, Ayhan S. A1 - Siegert, Petra A1 - Lingen, Bettina A1 - Baumann, Martin A1 - Pohl, Martina A1 - Müller, Michael T1 - Development of a donor-acceptor concept for enzymatic cross-coupling reactions of adehydes : the first asymmetric cross-benzoin condensation JF - Journal of the American Chemical Society Y1 - 2002 SN - 1520-5126 (E-Journal); 0002-7863 (Print) VL - Vol. 124 SP - 12084 EP - 12085 ER - TY - JOUR A1 - Biselli, Manfred A1 - Meissner, Petra A1 - Schröder, Bernd A1 - Herfurth, Cornelia T1 - Development of a fixed bed bioreactor for the expansion of human hematopoietic progenitor cells / Meissner, Petra ; Schröder, Bernd ; Herfurth, Cornelia ; Biselli, Manfred JF - Cytotechnology. 30 (1999), H. 1 Y1 - 1999 SN - 0920-9069 SP - 227 EP - 234 ER - TY - BOOK A1 - Havermann, Marc T1 - Development of a free flight force measuring (FFM) technique at the ISL shock tube laboratory : 25th International Symposium on Shock Waves, ISSW25, Bangalore, India, July 17 - 22, 2005 / Institut Franco-Allemand de Recherches de Saint-Louis. Seiler, F. ; Mathieu, G. ; George, A. ; Srulijes, J. ; Sauerwein, B. ; Havermann, M. Y1 - 2005 N1 - Publication / Institut Franco-Allemand de Recherches de Saint-Louis ; 620 PB - ISL CY - Saint-Louis ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Wagner, Torsten A1 - Wang, C. A1 - Otto, R. A1 - Yoshinobu, T. T1 - Development of a handheld 16 channel pen-type LAPS for electrochemical sensing JF - Sensors and Actuators B. 108 (2005) Y1 - 2005 SN - 0925-4005 SP - 808 EP - 814 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Wagner, Torsten A1 - Wang, C. A1 - Otto, R. A1 - Yoshinobu, T. T1 - Development of a handheld 16 channel pen-type LAPS for electrochemical sensing JF - Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors Y1 - 2004 N1 - Chemical sensors ; 20.2004 Suppl. B. IMCS ; (10, 2004, Tsukuba) ; International Meeting on Chemical Sensors ; (10 : ; 2004.07.11-14 : ; Tsukuba) SP - 136 EP - 137 PB - Japan Association of Chemical Sensors CY - Fukuoka ER - TY - JOUR A1 - Reisert, Steffen A1 - Henkel, Hartmut A1 - Schneider, Andreas A1 - Schäfer, Daniel A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Schöning, Michael Josef T1 - Development of a handheld sensor system for the online measurement of hydrogen peroxide in aseptic filling systems JF - Physica Status Solidi (A). 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 913 EP - 918 ER - TY - JOUR A1 - Trilla, Joan A1 - Grossen, Jürgen A1 - Robinson, Alexander A1 - Funke, Harald A1 - Bosschaerts, Walter A1 - Hendrick, Patrick T1 - Development of a hydrogen combustion chamber for an ultra micro gas turbine JF - PowerMEMS 2008, 8th International Workshop on Micro and Nanotechnology for Power Generation and Energy Conversion Applications, microEMS 2008, 2nd Symposium on Micro Environmental Machine Systems, Sendai, JP, Nov 9-12, 2008 Y1 - 2008 SP - 101 EP - 104 ER - TY - JOUR A1 - Robinson, A. E. A1 - Funke, Harald A1 - Hendrick, P. A1 - Recker, E. A1 - Peirs, J. T1 - Development of a hydrogen fuelled 1 kW ultra micro gas turbine with special respect to designing, testing and mapping of the µ-scale combustor JF - IEEE International Conference on Sustainable Energy Technologies, 2008 : ICSET 2008 ; Singapore, 24 - 27 Nov. 2008. Y1 - 2008 SN - 978-1-4244-1887-9 SP - 656 EP - 660 PB - IEEE CY - Piscataway, NJ ER - TY - CHAP A1 - Chico Caminos, Ricardo Alexander A1 - Schmitz, Pascal A1 - Atti, Vikrama A1 - Mahdi, Zahra A1 - Teixeira Boura, Cristiano José A1 - Sattler, Johannes Christoph A1 - Herrmann, Ulf A1 - Hilger, Patrick A1 - Dieckmann, Simon T1 - Development of a micro heliostat and optical qualification assessment with a 3D laser scanning method T2 - SOLARPACES 2020 N2 - The Solar-Institut Jülich (SIJ) and the companies Hilger GmbH and Heliokon GmbH from Germany have developed a small-scale cost-effective heliostat, called “micro heliostat”. Micro heliostats can be deployed in small-scale concentrated solar power (CSP) plants to concentrate the sun's radiation for electricity generation, space or domestic water heating or industrial process heat. In contrast to conventional heliostats, the special feature of a micro heliostat is that it consists of dozens of parallel-moving, interconnected, rotatable mirror facets. The mirror facets array is fixed inside a box-shaped module and is protected from weathering and wind forces by a transparent glass cover. The choice of the building materials for the box, tracking mechanism and mirrors is largely dependent on the selected production process and the intended application of the micro heliostat. Special attention was paid to the material of the tracking mechanism as this has a direct influence on the accuracy of the micro heliostat. The choice of materials for the mirror support structure and the tracking mechanism is made in favor of plastic molded parts. A qualification assessment method has been developed by the SIJ in which a 3D laser scanner is used in combination with a coordinate measuring machine (CMM). For the validation of this assessment method, a single mirror facet was scanned and the slope deviation was computed. KW - Concentrated solar power KW - Electricity generation KW - Measuring instruments KW - Heliostats KW - Global change Y1 - 2022 SN - 978-0-7354-4195-8 U6 - https://doi.org/10.1063/5.0086262 SN - 1551-7616 (online) SN - 0094-243X (print) N1 - SOLARPACES 2020: 26th International Conference on Concentrating Solar Power and Chemical Energy Systems, 28 September–2 October 2020, Freiburg, Germany IS - 2445 / 1 PB - AIP conference proceedings / American Institute of Physics CY - Melville, NY ER - TY - CHAP A1 - Reimer, Lars A1 - Braun, Carsten A1 - Wellmer, Georg A1 - Behr, Marek A1 - Ballmann, Josef T1 - Development of a modular method for computational aero-structural analysis of aircraft T2 - Summary of flow modulation and fluid-structure interaction findings. Results of the Collaborative Research Center SFB 401 at the RWTH Aachen University, Aachen, Germany, 1997-2008 / ed.: Wolfgang Schröder. Notes on numerical fluid mechanics and multidisciplinary design. Vol. 109 Y1 - 2010 SN - 978-3-642-04087-0 SP - 205 EP - 238 PB - Springer CY - Berlin ER - TY - JOUR A1 - Pilas, Johanna A1 - Iken, Heiko A1 - Selmer, Thorsten A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Development of a multi‐parameter sensor chip for the simultaneous detection of organic compounds in biogas processes JF - Physica status solidi (a) N2 - An enzyme-based multi-parameter biosensor is developed for monitoring the concentration of formate, d-lactate, and l-lactate in biological samples. The sensor is based on the specific dehydrogenation by an oxidized β-nicotinamide adenine dinucleotide (NAD+)-dependent dehydrogenase (formate dehydrogenase, d-lactic dehydrogenase, and l-lactic dehydrogenase, respectively) in combination with a diaphorase from Clostridium kluyveri (EC 1.8.1.4). The enzymes are immobilized on a platinum working electrode by cross-linking with glutaraldehyde (GA). The principle of the determination scheme in case of l-lactate is as follows: l-lactic dehydrogenase (l-LDH) converts l-lactate into pyruvate by reaction with NAD+. In the presence of hexacyanoferrate(III), the resulting reduced β-nicotinamide adenine dinucleotide (NADH) is then regenerated enzymatically by diaphorase. The electrochemical detection is based on the current generated by oxidation of hexacyanoferrate(II) at an applied potential of +0.3 V vs. an Ag/AgCl reference electrode. The biosensor will be electrochemically characterized in terms of linear working range and sensitivity. Additionally, the successful practical application of the sensor is demonstrated in an extract from maize silage. Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201431894 SN - 1862-6319 VL - 212 IS - 6 SP - 1306 EP - 1312 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Funke, Harald A1 - Robinson, A. E. T1 - Development of a new test rig for a micro scale hydrogen combustion chamber JF - Proceedings of the 2nd European Conference for Aero-Space Sciences : July 1 - 6, 2007, Brussels, Belgium Y1 - 2007 N1 - European Conference for Aerospace Sciences <2, 2007, Brüssel> ; EUCASS <2, 2007, Brüssel> ; Paper No. 22 SP - 1 EP - 8 PB - - ER - TY - THES A1 - Bayer, Robin T1 - Development of a novel in-vitro vascular model for determination of physiological and pathophysiological mechanobiology Y1 - 2021 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:38-362212 N1 - Dissertation, Universität zu Köln, 2021 PB - Universität zu Köln CY - Köln ER - TY - JOUR A1 - Jildeh, Zaid B. A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Vahidpour, Farnoosh A1 - Wagner, Patrick H. A1 - Schöning, Michael Josef T1 - Development of a package-sterilization process for aseptic filling machines: A numerical approach and validation for surface treatment with hydrogen peroxide JF - Sensor and Actuators A: Physical N2 - Within the present work a sterilization process by a heated gas mixture that contains hydrogen peroxide (H₂O₂) is validated by experiments and numerical modeling techniques. The operational parameters that affect the sterilization efficacy are described alongside the two modes of sterilization: gaseous and condensed H₂O₂. Measurements with a previously developed H₂O₂ gas sensor are carried out to validate the applied H₂O₂ gas concentration during sterilization. We performed microbiological tests at different H₂O₂ gas concentrations by applying an end-point method to carrier strips, which contain different inoculation loads of Geobacillus stearothermophilus spores. The analysis of the sterilization process of a pharmaceutical glass vial is performed by numerical modeling. The numerical model combines heat- and advection-diffusion mass transfer with vapor–pressure equations to predict the location of condensate formation and the concentration of H₂O₂ at the packaging surfaces by changing the gas temperature. For a sterilization process of 0.7 s, a H₂O₂ gas concentration above 4% v/v is required to reach a log-count reduction above six. The numerical results showed the location of H₂O₂ condensate formation, which decreases with increasing sterilant-gas temperature. The model can be transferred to different gas nozzle- and packaging geometries to assure the absence of H₂O₂ residues. Y1 - 2020 U6 - https://doi.org/10.1016/j.sna.2019.111691 SN - 0924-4247 VL - 303 IS - 111691 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Aboulnaga, Elhussiny A. A1 - Zou, Huibin A1 - Selmer, Thorsten A1 - Xian, Mo T1 - Development of a plasmid-based, tunable, tolC-derived expression system for application in Cupriavidus necator H16 JF - Journal of Biotechnology N2 - Cupriavidus necator H16 gains increasing attention in microbial research and biotechnological application due to its diverse metabolic features. Here we present a tightly controlled gene expression system for C. necator including the pBBR1-vector that contains hybrid promoters originating from C. necator native tolC-promoter in combination with a synthetic tetO-operator. The expression of the reporter gene from these plasmids relies on the addition of the exogenous inducer doxycycline (dc). The novel expression system offers a combination of advantageous features as; (i) high and dose-dependent recombinant protein production, (ii) tight control with a high dynamic range (On/Off ratio), which makes it applicable for harmful pathways or for toxic protein production, (iii) comparable cheap inducer (doxycycline, dc), (iv) effective at low inducer concentration, that makes it useful for large scale application, (v) rapid, diffusion controlled induction, and (vi) the inducer does not interfere within the cell metabolism. As applications of the expression system in C. necator H16, the growth ability on glycerol was enhanced by constitutively expressing the E. coli glpk gene-encoding for glycerol kinase. Likewise, we used the system to overcome the expression toxicity of mevalonate pathway in C. necator H16. With this system, the mevalonate-genes were successfully introduced in the host and the recombinant strains could produce about 200 mg/l mevalonate. Y1 - 2018 U6 - https://doi.org/10.1016/j.jbiotec.2018.03.007 SN - 0168-1656 VL - 274 SP - 15 EP - 27 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Biselli, Manfred A1 - Hambach, B. A1 - Runstadler, P. W. A1 - Wandrey, Christian T1 - Development of a reactor-integrated aeration system for cultivation of animal cells in fluidized beds / Hambach, B. ; Biselli, M. ; Runstadler, P.W. ; Wandrey, C. JF - Animal cell technology : developments, processes, and products ; ESACT, European Society for Animal Cell Technology, the 11th meeting / Ed. R. E. Spier Y1 - 1992 SN - 0750604212 SP - 381 EP - 385 PB - Butterworth-Heinemann CY - Oxford ER - TY - CHAP A1 - Hering, T. A1 - Ulber, Roland A1 - Tippkötter, Nils T1 - Development of a screening system for antimicrobial surfaces T2 - New frontiers of biotech-processes (Himmelfahrtstagung) : 02-04 May 2016, Rhein-Mosel-Halle, Koblenz/Germany Y1 - 2016 SP - 129 PB - DECHEMA CY - Frankfurt am Main ER - TY - CHAP A1 - Hoffschmidt, Bernhard A1 - Schwarzer, Klemens A1 - Späte, Frank A1 - Kötter, Jens A1 - Ebert, Miriam A1 - Sierck, Olaf T1 - Development of a small modular parabolic trough collector T2 - 13th International Symposium Concentrated Solar Power and Chemical Energy Technologies : SolarPaces : June 20 - 23, 2006, Seville, Spain Y1 - 2006 SN - 8478345191 PB - SolarPaces CY - [o.O.] ER - TY - CHAP A1 - Nursinski-Stolberg, André A1 - Gangatharan, Kiritharan A1 - Czarnecki, Christian ED - Mayr, Heinrich C. ED - Pinzger, Martin T1 - Development of a subject-oriented reference process model for the telecommunications industry T2 - GI Edition Proceedings Band 259 INFORMATIK 2016 N2 - Generally the usage of reference models can be structured top-down or bottom-up. The practical need of agile change and flexible organizational implementation requires a consistent mapping to an operational level. In this context, well-established reference process models are typically structured top-down. The subject-oriented Business Process Management (sBPM) offers a modeling concept that is structured bottom-up and concentrates on the process actors on an operational level. This paper applies sBPM to the enhanced Telecom Operations Map (eTOM), a well-accepted reference process model in the telecommunications industry. The resulting design artifact is a concrete example for a combination of a bottom-up and top-down developed reference model. The results are evaluated and confirmed in practical context through the involvement of the industry body TMForum. KW - Subject-oriented Business Process Management KW - Reference Process Model KW - eTOM KW - Telecommunications Industry. Y1 - 2016 SN - 9783885796534 SN - 1617-5468 N1 - 26.-30. September 2016, Klagenfurt. SP - 699 EP - 712 PB - Gesellschaft für Informatik e.V. CY - Bonn ER - TY - JOUR A1 - Wert, Stefan A1 - Iken, Heiko A1 - Schöning, Michael Josef A1 - Matysik, Frank-Michael T1 - Development of a temperature‐pulse enhanced electrochemical glucose biosensor and characterization of its stability via scanning electrochemical microscopy JF - Electroanalysis N2 - Glucose oxidase (GOx) is an enzyme frequently used in glucose biosensors. As increased temperatures can enhance the performance of electrochemical sensors, we investigated the impact of temperature pulses on GOx that was drop-coated on flattened Pt microwires. The wires were heated by an alternating current. The sensitivity towards glucose and the temperature stability of GOx was investigated by amperometry. An up to 22-fold increase of sensitivity was observed. Spatially resolved enzyme activity changes were investigated via scanning electrochemical microscopy. The application of short (<100 ms) heat pulses was associated with less thermal inactivation of the immobilized GOx than long-term heating. Y1 - 2021 U6 - https://doi.org/10.1002/elan.202100089 SN - 1521-4109 IS - Early View PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Hailer, Benjamin A1 - Weber, Tobias A1 - Neveling, Sebastian A1 - Dera, Samuel A1 - Arent, Jan-Christoph A1 - Middendorf, Peter T1 - Development of a test device to determine the frictional behavior between honeycomb and prepreg layers under realistic manufacturing conditions JF - Journal of Sandwich Structures & Materials N2 - In the friction tests between honeycomb with film adhesive and prepreg, the relative displacement occurs between the film adhesive and the prepreg. The film adhesive does not shift relative to the honeycomb. This is consistent with the core crush behavior where the honeycomb moves together with the film adhesive, as can be seen in Figure 2(a). The pull-through forces of the friction measurements between honeycomb and prepreg at 1 mm deformation are plotted in Figure 17(a). While the friction at 100°C is similar to the friction at 120°C, it decreases significantly at 130°C and exhibits a minimum at 140°C. At 150°C, the friction rises again slightly and then sharply at 160°C. Since the viscosity of the M18/1 prepreg resin drops significantly before it cures [23], the minimum friction at 140°C could result from a minimum viscosity of the mixture of prepreg resin and film adhesive before the bond subsequently cures. Figure 17(b) shows the mean value curve of the friction measurements at 140°C. The error bars, which represent the standard deviation, reveal the good repeatability of the tests. The force curve is approximately horizontal between 1 mm and 2 mm. The friction then slightly rises. As with interlaminar friction measurements, this could be due to the fact that resin is removed by friction and the proportion of boundary lubrication increases. Figure 18 shows the surfaces after the friction measurement. The honeycomb cell walls are clearly visible in the film adhesive. There are areas where the film adhesive is completely removed and the carrier material of the film adhesive becomes visible. In addition, the viscosity of the resin changes as the curing progresses during the friction test. This can also affect the force-displacement curve. Y1 - 2020 U6 - https://doi.org/10.1177/1099636220923986 SN - 1530-7972 IS - Volume 23, Issue 7 SP - 3017 EP - 3043 PB - Sage CY - London ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Kirsanov, Dmitry A1 - Legin, Andrey A1 - Osterrath, Thomas A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Schöning, Michael Josef T1 - Development of a thin-film sensor array for analytical monitoring of heavy metals in aqueous solutions JF - Physica Status Solidi (a) N2 - In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed. Y1 - 2012 SN - 1862-6319 U6 - https://doi.org/10.1002/pssa.201100733 VL - 209 IS - 5 SP - 885 EP - 891 PB - Wiley-VCH CY - Weinheim ER - TY - CHAP A1 - Hunker, Jan A1 - Jung, Alexander A1 - Goßmann, Matthias A1 - Linder, Peter A1 - Staat, Manfred ED - Staat, Manfred ED - Erni, Daniel T1 - Development of a tool to analyze the conduction speed in microelectrode array measurements of cardiac tissue T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - The discovery of human induced pluripotent stem cells reprogrammed from somatic cells [1] and their ability to differentiate into cardiomyocytes (hiPSC-CMs) has provided a robust platform for drug screening [2]. Drug screenings are essential in the development of new components, particularly for evaluating the potential of drugs to induce life-threatening pro-arrhythmias. Between 1988 and 2009, 14 drugs have been removed from the market for this reason [3]. The microelectrode array (MEA) technique is a robust tool for drug screening as it detects the field potentials (FPs) for the entire cell culture. Furthermore, the propagation of the field potential can be examined on an electrode basis. To analyze MEA measurements in detail, we have developed an open-source tool. Y1 - 2019 SN - 978-3-940402-22-6 U6 - https://doi.org/10.17185/duepublico/48750 SP - 7 EP - 8 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Röhlen, Desiree A1 - Pilas, Johanna A1 - Schöning, Michael Josef A1 - Selmer, Thorsten T1 - Development of an amperometric biosensor platform for the combined determination of l-Malic, Fumaric, and l-Aspartic acid JF - Applied Biochemistry and Biotechnology N2 - Three amperometric biosensors have been developed for the detection of L-malic acid, fumaric acid, and L -aspartic acid, all based on the combination of a malate-specific dehydrogenase (MDH, EC 1.1.1.37) and diaphorase (DIA, EC 1.8.1.4). The stepwise expansion of the malate platform with the enzymes fumarate hydratase (FH, EC 4.2.1.2) and aspartate ammonia-lyase (ASPA, EC 4.3.1.1) resulted in multi-enzyme reaction cascades and, thus, augmentation of the substrate spectrum of the sensors. Electrochemical measurements were carried out in presence of the cofactor β-nicotinamide adenine dinucleotide (NAD+) and the redox mediator hexacyanoferrate (III) (HCFIII). The amperometric detection is mediated by oxidation of hexacyanoferrate (II) (HCFII) at an applied potential of + 0.3 V vs. Ag/AgCl. For each biosensor, optimum working conditions were defined by adjustment of cofactor concentrations, buffer pH, and immobilization procedure. Under these improved conditions, amperometric responses were linear up to 3.0 mM for L-malate and fumarate, respectively, with a corresponding sensitivity of 0.7 μA mM−1 (L-malate biosensor) and 0.4 μA mM−1 (fumarate biosensor). The L-aspartate detection system displayed a linear range of 1.0–10.0 mM with a sensitivity of 0.09 μA mM−1. The sensor characteristics suggest that the developed platform provides a promising method for the detection and differentiation of the three substrates. Y1 - 2017 U6 - https://doi.org/10.1007/s12010-017-2578-1 SN - 1559-0291 VL - 183 SP - 566 EP - 581 PB - Springer CY - Berlin ER - TY - CHAP A1 - Achenbach, Timm A1 - Göttsche, Joachim A1 - Kaufhold, O. A1 - Hoffschmidt, Bernhard T1 - Development of an edge module for open volumetric receiver for the use of the radiation at the receiver boundary region T2 - SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain Y1 - 2011 CY - Granada ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schaffrath, Sophie A1 - Coppe, Thomas A1 - Rufi, Frederic A1 - Schöning, Michael Josef T1 - Development of an electrolyte-insulator-semiconductor (EIS) based capacitive heavy metal sensor for the detection of Pb2+ und Cd2+ ions JF - Physica status solidi (a) : applications and material science. 207 (2010), H. 4 Y1 - 2010 SN - 1862-6300 N1 - Special Issue: Engineering of Functional Interfaces EnFI 2009 SP - 930 EP - 934 ER - TY - JOUR A1 - Biselli, Manfred A1 - Van der Pol, Jens J. A1 - Joksch, B. A1 - Eberhardt, R. T1 - Development of an enzymatic multichannel flow injection analysis system for monitoring mammalian cell fermentations / Van der Pol, J.J.; Joksch, B.; Eberhardt, R.; Biselli, M.; Wandrey, C., Tramper, J. JF - Biosensors : fundamentals, technologies and applications ; contributions to the BMFT status seminar with international participation May, 12 to 14, 1991, Internationales Bildungs-Centrum Bogensee/Brandenburg, Germany / org. by ZIM-Zentralinstitut für Molekularbiologie, Berlin-Buch and GBF, Braunschweig. Ed. by F. Scheller Y1 - 1992 SN - 3527284370 N1 - GBF Monographs ; 17 SP - 349 EP - 352 PB - VCH CY - Weinheim ER - TY - JOUR A1 - Jildeh, Zaid B. A1 - Kirchner, Patrick A1 - Baltes, Klaus A1 - Wagner, Patrick H. A1 - Schöning, Michael Josef T1 - Development of an in-line evaporation unit for the production of gas mixtures containing hydrogen peroxide – numerical modeling and experimental results JF - International Journal of Heat and Mass Transfer N2 - Hydrogen peroxide (H2O2) is a typical surface sterilization agent for packaging materials used in the pharmaceutical, food and beverage industries. We use the finite-elements method to analyze the conceptual design of an in-line thermal evaporation unit to produce a heated gas mixture of air and evaporated H2O2 solution. For the numerical model, the required phase-transition variables of pure H2O2 solution and of the aerosol mixture are acquired from vapor-liquid equilibrium (VLE) diagrams derived from vapor-pressure formulations. This work combines homogeneous single-phase turbulent flow with heat-transfer physics to describe the operation of the evaporation unit. We introduce the apparent heat-capacity concept to approximate the non-isothermal phase-transition process of the H2O2-containing aerosol. Empirical and analytical functions are defined to represent the temperature- and pressure-dependent material properties of the aqueous H2O2 solution, the aerosol and the gas mixture. To validate the numerical model, the simulation results are compared to experimental data on the heating power required to produce the gas mixture. This shows good agreement with the deviations below 10%. Experimental observations on the formation of deposits due to the evaporation of stabilized H2O2 solution fits the prediction made from simulation results. Y1 - 2019 U6 - https://doi.org/10.1016/j.ijheatmasstransfer.2019.118519 SN - 0017-9310 VL - 143 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Grund, Raphael M. A1 - Altherr, Lena ED - Reiff-Stephan, Jörg ED - Jäkel, Jens ED - Schwarz, André T1 - Development of an open source energy disaggregation tool for the home automation platform Home Assistant T2 - Tagungsband AALE 2023 : mit Automatisierung gegen den Klimawandel N2 - In order to reduce energy consumption of homes, it is important to make transparent which devices consume how much energy. However, power consumption is often only monitored aggregated at the house energy meter. Disaggregating this power consumption into the contributions of individual devices can be achieved using Machine Learning. Our work aims at making state of the art disaggregation algorithms accessibe for users of the open source home automation platform Home Assistant. KW - Home Automation Platform KW - Home Assistant KW - Open Source KW - Machine Learning KW - Energy Disaggregation Y1 - 2023 SN - 978-3-910103-01-6 U6 - https://doi.org/10.33968/2023.02 N1 - 19. AALE-Konferenz. Luxemburg, 08.03.-10.03.2023. BTS Connected Buildings & Cities Luxemburg (Tagungsband unter https://doi.org/10.33968/2023.01) SP - 11 EP - 20 PB - le-tex publishing services GmbH CY - Leipzig ER - TY - JOUR A1 - Mosset, J.-B. A1 - Devroede, O. A1 - Krieguer, M. A1 - Rey, M. A1 - Vieira, J.-M. A1 - Jung, J. H. A1 - Kuntner, C. A1 - Streun, M. A1 - Ziemons, Karl A1 - Auffray, E. A1 - Sempere-Roldan, P. A1 - Lecoq, P. A1 - Bruyndonckx, P. A1 - Loude, J.-F. A1 - Tavernier, S. A1 - Morcel, C. T1 - Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator JF - IEEE Transactions on Nuclear Science N2 - This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 1 SP - 25 EP - 29 ER - TY - JOUR A1 - Hoffschmidt, Bernhard A1 - Fernandez, V. A1 - Konstandopoulus, A. G. T1 - Development of ceramic volumetric receiver technology JF - Forschungsbericht : DLR FB. 10 (2001) Y1 - 2001 SN - 0939-2963 N1 - 2. ISSN: 1434-8454 ; Kölner Sonnenkolloquium <5, 2001, Köln> ; Solar thermal power plants and solar chemical processes : advances and perspectives for international cooperation SP - 51 EP - 61 ER - TY - JOUR A1 - Edip, K. A1 - Sesov, V. A1 - Butenweg, Christoph A1 - Bojadjieva, J. T1 - Development of coupled numerical model for simulation of multiphase soil JF - Computers and Geotechnics N2 - In this paper, a coupled multiphase model considering both non-linearities of water retention curves and solid state modeling is proposed. The solid displacements and the pressures of both water and air phases are unknowns of the proposed model. The finite element method is used to solve the governing differential equations. The proposed method is demonstrated through simulation of seepage test and partially consolidation problem. Then, implementation of the model is done by using hypoplasticity for the solid phase and analyzing the fully saturated triaxial experiments. In integration of the constitutive law error controlling is improved and comparisons done accordingly. In this work, the advantages and limitations of the numerical model are discussed. Y1 - 2018 U6 - https://doi.org/10.1016/j.compgeo.2017.08.016 SN - 0266-352X VL - 96 SP - 118 EP - 131 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Teixeira Boura, Cristiano José A1 - Niederwestberg, Stefan A1 - McLeod, Jacqueline A1 - Herrmann, Ulf A1 - Hoffschmidt, Bernhard T1 - Development of heat exchanger for high temperature energy storage with bulk materials T2 - AIP Conference Proceedings Y1 - 2016 U6 - https://doi.org/10.1063/1.4949106 VL - 1734 IS - 1 SP - 050008-1 EP - 050008-7 ER - TY - CHAP A1 - Sattler, Johannes Christoph A1 - Schneider, Iesse Peer A1 - Angele, Florian A1 - Atti, Vikrama A1 - Teixeira Boura, Cristiano José A1 - Herrmann, Ulf T1 - Development of heliostat field calibration methods: Theory and experimental test results T2 - SolarPACES 2022 conference proceedings N2 - In this work, three patent pending calibration methods for heliostat fields of central receiver systems (CRS) developed by the Solar-Institut Jülich (SIJ) of the FH Aachen University of Applied Sciences are presented. The calibration methods can either operate in a combined mode or in stand-alone mode. The first calibration method, method A, foresees that a camera matrix is placed into the receiver plane where it is subjected to concentrated solar irradiance during a measurement process. The second calibration method, method B, uses an unmanned aerial vehicle (UAV) such as a quadrocopter to automatically fly into the reflected solar irradiance cross-section of one or more heliostats (two variants of method B were tested). The third calibration method, method C, foresees a stereo central camera or multiple stereo cameras installed e.g. on the solar tower whereby the orientations of the heliostats are calculated from the location detection of spherical red markers attached to the heliostats. The most accurate method is method A which has a mean accuracy of 0.17 mrad. The mean accuracy of method B variant 1 is 1.36 mrad and of variant 2 is 1.73 mrad. Method C has a mean accuracy of 15.07 mrad. For method B there is great potential regarding improving the measurement accuracy. For method C the collected data was not sufficient for determining whether or not there is potential for improving the accuracy. KW - Heliostat Field Calibration KW - Unmanned aerial vehicle KW - UAV KW - Quadrocopter KW - Camera system Y1 - 2024 U6 - https://doi.org/10.52825/solarpaces.v1i.678 SN - 2751-9899 (online) N1 - SolarPACES 2022: 28th International Conference on Concentrating Solar Power and Chemical Energy Systems, 27-30 September, Albuquerque, NM, USA IS - 1 PB - TIB Open Publishing CY - Hannover ER -