TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Friedrich, Peter A1 - Berger, Jörg A1 - Rysstad, Gunnar A1 - Schöning, Michael Josef A1 - Keusgen, Michael T1 - Realisation of a calorimetric gas sensor on polyimide foil for applications in aseptic food industry JF - Sensors and Actuators B: Chemical N2 - A calorimetric gas sensor is presented for the monitoring of vapour-phase H2O2 at elevated temperature during sterilisation processes in aseptic food industry. The sensor was built up on a flexible polyimide foil (thickness: 25 μm) that has been chosen due to its thermal stability and low thermal conductivity. The sensor set-up consists of two temperature-sensitive platinum thin-film resistances passivated by a layer of SU-8 photo resist and catalytically activated by manganese(IV) oxide. Instead of an active heating structure, the calorimetric sensor utilises the elevated temperature of the evaporated H2O2 aerosol. In an experimental test rig, the sensor has shown a sensitivity of 4.78 °C/(%, v/v) in a H2O2 concentration range of 0%, v/v to 8%, v/v. Furthermore, the sensor possesses the same, unchanged sensor signal even at varied medium temperatures between 210 °C and 270 °C of the gas stream. At flow rates of the gas stream from 8 m3/h to 12 m3/h, the sensor has shown only a slightly reduced sensitivity at a low flow rate of 8 m3/h. The sensor characterisation demonstrates the suitability of the calorimetric gas sensor for monitoring the efficiency of industrial sterilisation processes. KW - Sterilisation process KW - Hydrogen peroxide KW - Polyimide KW - Calorimetric gas sensor Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.snb.2011.01.032 SN - 0925-4005 N1 - Part of special issue "Eurosensors XXIV, 2010" VL - 170 SP - 60 EP - 66 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bertz, Morten A1 - Molinnus, Denise A1 - Schöning, Michael Josef A1 - Homma, Takayuki T1 - Real-time monitoring of H₂O₂ sterilization on individual bacillus atrophaeus spores by optical sensing with trapping Raman spectroscopy JF - Chemosensors N2 - Hydrogen peroxide (H₂O₂), a strong oxidizer, is a commonly used sterilization agent employed during aseptic food processing and medical applications. To assess the sterilization efficiency with H₂O₂, bacterial spores are common microbial systems due to their remarkable robustness against a wide variety of decontamination strategies. Despite their widespread use, there is, however, only little information about the detailed time-resolved mechanism underlying the oxidative spore death by H₂O₂. In this work, we investigate chemical and morphological changes of individual Bacillus atrophaeus spores undergoing oxidative damage using optical sensing with trapping Raman microscopy in real-time. The time-resolved experiments reveal that spore death involves two distinct phases: (i) an initial phase dominated by the fast release of dipicolinic acid (DPA), a major spore biomarker, which indicates the rupture of the spore’s core; and (ii) the oxidation of the remaining spore material resulting in the subsequent fragmentation of the spores’ coat. Simultaneous observation of the spore morphology by optical microscopy corroborates these mechanisms. The dependence of the onset of DPA release and the time constant of spore fragmentation on H₂O₂ shows that the formation of reactive oxygen species from H₂O₂ is the rate-limiting factor of oxidative spore death. KW - DPA (dipicolinic acid) KW - sterilization KW - Bacillus atrophaeus spores KW - optical trapping KW - Raman spectroscopy KW - optical sensor setup Y1 - 2023 U6 - http://dx.doi.org/10.3390/chemosensors11080445 SN - 2227-9040 N1 - This article belongs to the Special Issue "Biosensors and Chemical Sensors for Food and Healthcare Monitoring—Celebrating the 10th Anniversary" VL - 8 IS - 11 PB - MDPI CY - Basel ER - TY - CHAP A1 - Poghossian, Arshak A1 - Schusser, Sebastian A1 - Bäcker, M. A1 - Leinhos, Marcel A1 - Schöning, Michael Josef T1 - Real-time in-situ electrical monitoring of the degradation of biopolymers using semiconductor field-effect devices T2 - Biodegradable biopolymers. Vol. 1 Y1 - 2015 SN - 978-1-63483-632-6 SP - 135 EP - 153 PB - Nova Science Publ. CY - Hauppauge ER - TY - JOUR A1 - Bohrn, U. A1 - Stütz, E. A1 - Fleischer, M. A1 - Schöning, Michael Josef T1 - Real-time detection of CO by eukaryotic cells JF - Procedia Engineering. 5 (2010) Y1 - 2010 SN - 1877-7058 N1 - Eurosensor XXIV Conference SP - 17 EP - 20 ER - TY - JOUR A1 - Röthenbacher, Annika A1 - Cesari, Matteo A1 - Doppler, Christopher E.J. A1 - Okkels, Niels A1 - Willemsen, Nele A1 - Sembowski, Nora A1 - Seger, Aline A1 - Lindner, Marie A1 - Brune, Corinna A1 - Stefani, Ambra A1 - Högl, Birgit A1 - Bialonski, Stephan A1 - Borghammer, Per A1 - Fink, Gereon R. A1 - Schober, Martin A1 - Sommerauer, Michael T1 - RBDtector: an open-source software to detect REM sleep without atonia according to visual scoring criteria JF - Scientific Reports N2 - REM sleep without atonia (RSWA) is a key feature for the diagnosis of rapid eye movement (REM) sleep behaviour disorder (RBD). We introduce RBDtector, a novel open-source software to score RSWA according to established SINBAR visual scoring criteria. We assessed muscle activity of the mentalis, flexor digitorum superficialis (FDS), and anterior tibialis (AT) muscles. RSWA was scored manually as tonic, phasic, and any activity by human scorers as well as using RBDtector in 20 subjects. Subsequently, 174 subjects (72 without RBD and 102 with RBD) were analysed with RBDtector to show the algorithm’s applicability. We additionally compared RBDtector estimates to a previously published dataset. RBDtector showed robust conformity with human scorings. The highest congruency was achieved for phasic and any activity of the FDS. Combining mentalis any and FDS any, RBDtector identified RBD subjects with 100% specificity and 96% sensitivity applying a cut-off of 20.6%. Comparable performance was obtained without manual artefact removal. RBD subjects also showed muscle bouts of higher amplitude and longer duration. RBDtector provides estimates of tonic, phasic, and any activity comparable to human scorings. RBDtector, which is freely available, can help identify RBD subjects and provides reliable RSWA metrics. Y1 - 2022 U6 - http://dx.doi.org/10.1038/s41598-022-25163-9 SN - 2045-2322 VL - 12 IS - Article number: 20886 SP - 1 EP - 14 PB - Springer Nature CY - London ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Lieder, R. M. A1 - Neskakis, A. T1 - Ratios of cascade and cross-over transitions in ¹⁹⁵,¹⁹⁷ Tl JF - Annual report 1977 / Institut für Kernphysik Kernforschungsanlage Jülich Y1 - 1978 N1 - Spezielle Berichte der Kernforschungsanlage Jülich ; 15 SP - 48 EP - 49 PB - Verlag des Forschungszentrums Jülich CY - Jülich ER - TY - JOUR A1 - Poghossian, Arshak A1 - Geissler, Hanno A1 - Schöning, Michael Josef T1 - Rapid methods and sensors for milk quality monitoring and spoilage detection JF - Biosensors and Bioelectronics Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.bios.2019.04.040 SN - 0956-5663 VL - 140 IS - Article 111272 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hillen, Walter T1 - Rapid growth of charged particle multiplicity in high energy e+e− annihilations. TASSO Collaboration JF - Physics Letters B. 89 (1980), H. 3-4 Y1 - 1980 SN - 0370-2693 SP - 418 EP - 422 ER - TY - JOUR A1 - Grinsven, B. van A1 - Bon, N. vanden A1 - Grieten, L. A1 - Murib, M. A1 - Janssen, S. D. A1 - Haenen, K. A1 - Schneider, E. A1 - Ingebrandt, E. A1 - Schöning, Michael Josef A1 - Vermeeren, V. A1 - Ameloot, M. A1 - Michiels, L. A1 - Thoelen, R. A1 - Ceuninck, W. de A1 - Wagner, P. T1 - Rapid assessment of the stability of DNA duplexes by impedimetric real-time monitoring of chemically induced denaturation JF - Lab on a Chip Y1 - 2011 SN - 1473-0197 VL - 11 IS - 9 SP - 1656 EP - 1663 PB - Royal Society of Chemistry (RSC) CY - Cambridge ER - TY - JOUR A1 - Hackl, Michael A1 - Wegmann, Kilian A1 - Kahmann, Stephanie Lucina A1 - Heinze, Nicolai A1 - Staat, Manfred A1 - Neiss, Wolfram F. A1 - Scaal, Martin A1 - Müller, Lars P. T1 - Radial shortening osteotomy reduces radiocapitellar contact pressures while preserving valgus stability of the elbow JF - Knee Surgery, Sports Traumatology, Arthroscopy Y1 - 2017 U6 - http://dx.doi.org/10.1007/s00167-017-4468-z SN - 1433-7347 VL - 25 IS - 7 SP - 2280 EP - 2288 PB - Springer CY - Berlin ER - TY - CHAP A1 - Mirmohseni, Abdolreza A1 - Rostamizadeh, Kobra T1 - Quartz crystal nanobalance in conjunction with principal component analysis for identification of volatile organic compounds N2 - Quartz crystal nanobalance (QCN) sensors are considered as powerful masssensitive sensors to determine materials in the sub-nanogram level. In this study, a single piezoelectric quartz crystal nanobalance modified with polystyrene was employed to detect benzene, toluene, ethylbenzene and xylene (BTEX compounds). The frequency shift of the QCN sensor was found to be linear against the BTEX compound concentrations in the range about 1-45 mg l-1. The correlation coefficients for benzene, toluene, ethylbenzene, and xylene were 0.991, 0.9977, 0.9946 and 0.9971, respectively. The principal component analysis was also utilized to process the frequency response data of the single piezoelectric crystal at different times, considering to the different adsorption-desorption dynamics of BTEX compounds. Using principal component analysis, it was found that over 90% of the data variance could still be explained by use of two principal components (PC1 and PC2). Subsequently, the successful identification of benzene and toluene was possible through the principal component analysis of the transient responses of the polystyrene modified QCN sensor. The results showed that the polystyrene-modified QCN had favorable identification and quantification performances for the BTEX compounds. KW - Biosensor KW - Quartz crystal nanobalance (QCN) KW - BTEX compounds KW - principal component Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1434 ER - TY - JOUR A1 - Stulpe, Werner A1 - Swat, Maciej T1 - Quantum States as Probability Measures JF - Foundations of Physics Letters. 14 (2001), H. 3 Y1 - 2001 SN - 1572-9524 SP - 285 EP - 293 ER - TY - BOOK A1 - Grotendorst, Johannes T1 - Quantum Simulations of Complex Many-Body Systems: From Theory to Algorithms, Audio-Visual Lecture Notes / Grotendorst, Johannes [Ed.] Y1 - 2002 SN - 3-00-010000-8 N1 - NIC series ; 14 PB - NIC CY - Jülich ER - TY - BOOK A1 - Grotendorst, Johannes T1 - Quantum simulations of complex many-body systems: from theory to algorithms : winter school, 25 February - 1 March 2002, Rolduc Conference Centre, Kerkrade, the Netherlands ; poster presentations / ed. by Johannes Grotendorst Y1 - 2002 SN - 3-00-009058-4 N1 - NIC series ; 11 ; Winter school ; (2002.02.25-03.01 : ; Kerkrade) PB - NIC CY - Jülich ER - TY - BOOK A1 - Grotendorst, Johannes T1 - Quantum simulations of complex many body systems/<1> Y1 - 2002 SN - 3-00-009057-6 N1 - NIC series ; 10 ; John-von-Neumann-Institut für Computing PB - Forschungszentrum Jülich CY - Jülich ER - TY - JOUR A1 - Schäfer, Horst A1 - Shao, H. A1 - Gerschütz, J. A1 - Scholl, S. (u.a.) T1 - Quantum Interference Effects in Highly Doped n-ZnSe Epitaxy Layers Grown by MBE JF - physica status solidi (b). 206 (1998), H. 2 Y1 - 1998 SN - 0370-1972 SP - 575 EP - 582 ER - TY - JOUR A1 - Schäfer, Horst A1 - Scholl, S. A1 - Gerschütz, F. A1 - Fischer, A. T1 - Quantum Hall Effect in CdTe/Cd 1-X MgX Te Heterostructures JF - Solid State Communications. 94 (1995), H. 11 Y1 - 1995 SN - 0038-1098 SP - 935 EP - 938 ER - TY - JOUR A1 - Schäfer, Horst A1 - Shao, Hua A1 - Scholl, W. A1 - Hommel, D. (u.a.) T1 - Quantum Corrections to Magnetotransport in n-ZnSe Grown by MBE Y1 - 1995 N1 - Als Poster vorgelegt auf der Frühjahrstagung der DPG in Berlin, 20.-24. März 1995, Verhandl. DPG (VI) 30, HL 28.76 / Physikalisches Institut der Universität Würzburg. ER - TY - JOUR A1 - Dantism, Shahriar A1 - Röhlen, Desiree A1 - Selmer, Thorsten A1 - Wagner, Torsten A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Quantitative differential monitoring of the metabolic activity of Corynebacterium glutamicum cultures utilizing a light-addressable potentiometric sensor system JF - Biosensors and Bioelectronics Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.bios.2019.111332 VL - 139 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Iomdina, Elena N. A1 - Kiseleva, Anna A. A1 - Kotliar, Konstantin A1 - Luzhnov, Petr V. T1 - Quantification of Choroidal Blood Flow Using the OCT-A System Based on Voxel Scan Processing T2 - 2020 International Conference on Biomedical Innovations and Applications (BIA) Y1 - 2020 SN - 978-1-7281-7073-2 U6 - http://dx.doi.org/10.1109/BIA50171.2020.9244511 SP - 41 EP - 44 ER - TY - JOUR A1 - Schäfer, Horst A1 - Gerschütz, J. A1 - Scholl, S. A1 - Fischer, A. (u.a.) T1 - Quanten-Hall-Effekt in CdTe/Cd1-X MgX Te Heterostrukturen Y1 - 1995 N1 - Als Poster vorgelegt auf der Frühjahrstagung der DPG in Berlin, 20.-24. März 1995, Verhandl. DPG (VI) 30, HL 33.52 / Physikalisches Institut der Universität Würzburg. ER - TY - JOUR A1 - Kloock, Joachim P. A1 - Mourzina, Y. A1 - Schubert, J. A1 - Ermelenko, Y. A1 - Schöning, Michael Josef T1 - Pulsed laser deposition: A tool for fabricating thin-film microsensors JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 1032 EP - 1033 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Mourzina, Yu.G. A1 - Schubert, J. A1 - Zander, W. A1 - Legin, A. A1 - Vlasov, Y. G. A1 - Lüth, H. T1 - Pulsed laser deposition – an innovative technique for preparing inorganic thin films JF - Electroanalysis. 13 (2001), H. 8-9 Y1 - 2001 SN - 1040-0397 SP - 727 EP - 732 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schaub, A. A1 - Zundel, A. A1 - Beckers, L. A1 - Schubert, J. A1 - Zander, W. A1 - Kordos, P. A1 - Lüth, H. T1 - Pulsed laser deposition as a novel thin film preparation method for silicon-based field effect sensors JF - Proceedings of the 25th European Solid State Device Research Conference : the Netherlands Congress Centre, The Hague, the Netherlands, 25th - 27th September 1995 / ESSDERC '95. Ed. by H. C. de Graaff Y1 - 1995 SN - 2-86332-182-X N1 - ESSDERC ; (25, 1995, 's-Gravenhage) ; European Solid State Device Research Conference (ESSDERC) ; (25 : ; 1995.09.25-27 : ; Den Haag) SP - 601 EP - 604 PB - Ed. Frontières CY - Gif-sur-Yvette ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Schubert, Jürgen A1 - Zander, Willy A1 - Müller-Veggian, Mattea T1 - Pulsed laser deposition as a novel preparation technique for chemical microsensors JF - Proceedings of SPIE 3857, Chemical Microsenors and Applications II, 124 (November 18, 1999). 3857 (1999) Y1 - 1999 SP - 124 EP - 134 ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Baumann, Marcus A1 - Vilser, Walthard A1 - Lanzl, Ines M. T1 - Pulse wave velocity in retinal arteries of healthy volunteers JF - British Journal of Ophthalmology (eBJO) Y1 - 2011 SN - 1468-2079 VL - 95 IS - 11 SP - 675 EP - 679 PB - BMJ Publ. Group CY - London ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - 2002 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A feasible way to gain the depth of interaction information in a PET scanner is the use of phoswich detectors. In general the layer of interaction is identified front the pulse shape of the corresponding scintillator material. In this work pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could he kept simple due to an additional slow component in the light decay of the LuYAP pulse. At the same time the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 1082-3654 SP - 1636 EP - 1639 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Saleh, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET JF - IEEE Transactions on Nuclear Science N2 - A feasible way to gain the depth of interaction information in a positron emission tomography scanner is the use of phoswich detectors. In general, the layer of interaction is identified from the pulse shape of the corresponding scintillator material. In this work, pulses from LSO and LuYAP crystals were investigated in order to find a practical method of distinguishing. It turned out that such a pulse processing could be kept simple because of an additional slow component in the light decay of the LuYAP pulse. At the same time, the short decay time guarantees that the major amount of the light output is still collected within a short pulse recording time. Y1 - 2003 SN - 0018-9499 VL - 50 IS - 3 SP - 344 EP - 347 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse recording by free-running sampling JF - 2000 IEEE Nuclear Science Symposium Conference Record, Vol. 2 N2 - Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free running ADCs at a sampling rate of 40 MHz. A four-channel acquisition-board has been developed which is equipped with four 12 bit-ADCs connected to one FPGA (field programmable gate array). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware-trigger can be omitted. The method of free running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. These informations are crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows coping with very high count rates. Since this method is going to be employed in positron emission tomography (PET), the position of an event is another important information. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO-scintillators coupled to the PS-PMT are presented Y1 - 2000 SN - 1082-3654 SP - 9/179 EP - 9/181 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Zimmermann, E. A1 - Ziemons, Karl A1 - Halling, H. T1 - Pulse recording by free-running sampling JF - IEEE Transactions on Nuclear Science N2 - Pulses from a position-sensitive photomultiplier (PS-PMT) are recorded by free-running ADCs at a sampling rate of 40 MHz. A four-channel acquisition board has been developed which is equipped with four 12-bit ADCs connected to one field programmable gate array (FPGA). The FPGA manages data acquisition and the transfer to the host computer. It can also work as a digital trigger, so a separate hardware trigger can be omitted. The method of free-running sampling provides a maximum of information, besides the pulse charge and amplitude also pulse shape and starting time are contained in the sampled data. This information is crucial for many tasks such as distinguishing between different scintillator materials, determination of radiation type, pile-up recovery, coincidence detection or time-of-flight applications. The absence of an analog integrator allows very high count rates to be dealt with. Since this method is to be employed in positron emission tomography (PET), the position of an event is also important. The simultaneous readout of four channels allows localization by means of center-of-gravity weighting. First results from a test setup with LSO scintillators coupled to the PS-PMT are presented here Y1 - 2001 SN - 0018-9499 VL - 48 IS - 3 SP - 524 EP - 526 ER - TY - JOUR A1 - Hackl, Michael A1 - Müller, Lars-Peter A1 - Staat, Manfred A1 - Kahmann, Stephanie Lucina A1 - Wegmann, Kilian T1 - Proximal phalangeal neck fractures of the hand — a biomechanical comparison of three fixation techniques JF - Knee surgery, sports traumatology, arthroscopy N2 - Plate osteosynthesis of displaced proximal phalangeal neck fractures of the hand allows early mobilization due to a stable internal fixation. Nevertheless, joint stiffness—because of soft tissue irritation—represents a common complication leading to high complication rates. Del Pinal et al. recently reported promising clinical results for a new, minimally invasive fixation technique with a cannulated headless intramedullary compression screw. Hence, the aim of this study was to compare plate fixation of proximal phalangeal neck fractures to less two less invasive techniques: Crossed k-wire fixation and intramedullary screw fixation. We hypothesized that these fixation techniques provide inferior stability when compared to plate osteosynthesis. Y1 - 2016 U6 - http://dx.doi.org/10.1007/s00167-016-4080-7 SN - 0942-2056 VL - Volume 24 IS - Supplement 1 SP - 148 EP - 149 PB - Springer CY - Berlin ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Gueven, H. A1 - Lach, M. A1 - Styczen, J. T1 - Proton- and neutron h 11/2 exitations in ¹⁴¹ Eu JF - Annual report 1987 / Kernforschungsanlage Jülich Institut für Kernphysik / Grümmer, F. (Hrsg.) . - (Spezielle Berichte der Kernforschungsanlage Jülich ; 442) Y1 - 1988 SP - 43 PB - Verlag des Forschungszentrums Jülich CY - Jülich ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Gueven, H. A1 - Julin, R. A1 - Lach, M T1 - Proton- and neutron H 11/2 excitations in 63 141 Eu 78 JF - Zeitschrift für Physik / A, Hadrons and nuclei. 330 (1988), H. 4 Y1 - 1988 SN - 1431-5831 N1 - 2. ISSN: 0340-2193 ; 3. ISSN 0930-1151 ; 4. ISSN 0939-7922 SP - 437 EP - 438 ER - TY - JOUR A1 - Digel, Ilya A1 - Zerlin, Kay A1 - Temiz Artmann, Aysegül A1 - Engels, S. T1 - Protein dynamics in thermosensation JF - Regenerative medicine. 2 (2007), H. 5 Y1 - 2007 SN - 1746-0751 N1 - Proceedings of the 3rd World Congress on Regenerative Medicine. October 18-20, 2007. Leipzig, Germany SP - 533 EP - 533 ER - TY - CHAP A1 - Savitskaya, Irina S. A1 - Kistaubayeva, Aida S. A1 - Akimbekov, Nuraly A1 - Digel, Ilya A1 - Shokatayeva, Dina A1 - Zhubanova, Azhar Achmet T1 - Prospective Use of Probiotics Immobilized on Sorbents with Nanostructured Surfaces T2 - Carbon Nanomaterials in Biomedicine and the Environment N2 - Activated carbons are known as excellent adsorbents. Their applications include the adsorptive removal of color, odor, taste, undesirable organic and inorganic pollutants from drinking and waste water; air purification in inhabited spaces; purification of many chemicals, pharmaceutical products and many others. This chapter elucidates the role of normal microflora in the maintenance of human health and presents materials on possible clinical displays of microecological infringements and ways of their correction. It presents new developments concerning new probiotics with immobilized Lactobacillus and Bacillus. The chapter considers the mechanisms of the intestine disbacteriosis correction by sorbed probiotics. It demonstrates the advantages and creation prospects of immobilized probiotics developed on the basis of carbonized rice husk. There are great prospects for the development of medical biotechnology due to use of carbon sorbents with a nanostructured surface. Microbial communities form a biocenosis of the biotope and together with the host organism create permanent or temporary ecosystems. Y1 - 2020 SN - 978-981-4800-27-3 U6 - http://dx.doi.org/10.1201/9780429428647-12 SP - 229 EP - 267 PB - Jenny Stanford Publishing CY - Singapore ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Neskakis, A. A1 - Lieder, R. M. A1 - Beuscher, H. T1 - Properties of side bands observed in ¹⁸⁰ Os JF - Zeitschrift für Physik / A, Hadrons and nuclei. 304 (1982), H. 3 Y1 - 1982 SN - 1431-5831 N1 - 2. ISSN: 0340-2193 ; 3. ISSN 0930-1151 ; 4. ISSN 0939-7922 SP - 277 EP - 278 ER - TY - JOUR A1 - Hillen, Walter T1 - Properties of hadron final states in e+e− annihilation at 13 GeV and 17 GeV center of mass energies. TASSO Collaboration JF - Physics Letters B. 83 (1979), H. 2 Y1 - 1979 SN - 0370-2693 SP - 261 EP - 266 ER - TY - JOUR A1 - Stulpe, Werner A1 - Ruch, Ernst T1 - Proof of the Mixing Theorem for Statistical Systems in Classical Physics. Ruch, Ernst; Stulpe, Werner JF - Acta Applicandae Mathematicae. 53 (1998), H. 3 Y1 - 1998 SN - 1572-9036 SP - 329 EP - 352 ER - TY - JOUR A1 - Jiminez German, Salvador A1 - Behbahani, Mehdi A1 - Miettinen, Susanna A1 - Grijpma, Dirk W. A1 - Haimi, Suvi P. T1 - Proliferation and differentiation of adipose stem cells towards smooth muscle cells on poly(trimethylene carbonate) membranes JF - Macromolecular symposia Y1 - 2013 SN - 0258-0322 VL - Vol. 334 IS - Iss. 1 SP - 133 EP - 142 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Stulpe, Werner T1 - Projection JF - Compendium of Quantum Physics : concepts, experiments, history and philosophy / Daniel Greenberger ... ed. Y1 - 2009 SN - 978-3-540-70622-9 SP - 497 EP - 499 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hillen, Walter T1 - Production and properties of the τ-lepton in e+e− annihilation at C.M. energies from 12 to 31.6 GeV. TASSO Collaboration JF - Physics Letters B. 92 (1980), H. 1-2 Y1 - 1980 SN - 0370-2693 SP - 199 EP - 205 ER - TY - JOUR A1 - Kopp, Alexander A1 - Schmeets, Ralf A1 - Gosau, Martin A1 - Friedrich, Reinhard E. A1 - Fuest, Sandra A1 - Behbahani, Mehdi A1 - Barbeck, Mike A1 - Rutkowski, Rico A1 - Burg, Simon A1 - Kluwe, Lan A1 - Henningsen, Anders T1 - Production and Characterization of Porous Fibroin Scaffolds for Regenerative Medical Application JF - In Vivo Y1 - 2019 U6 - http://dx.doi.org/10.21873/invivo.11536 SN - 1791-7549 VL - 33 IS - 3 SP - 757 EP - 762 ER - TY - CHAP A1 - Staat, Manfred T1 - Problems and chances for probabilistic fracture mechanics in the analysis of steel pressure boundary reliability. - Überarb. Ausg. N2 - In: Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994. - Vienna , 1996. - Seite: 43 - 55 IAEA-TECDOC-920 Abstract: It is shown that the difficulty for probabilistic fracture mechanics (PFM) is the general problem of the high reliability of a small population. There is no way around the problem as yet. Therefore what PFM can contribute to the reliability of steel pressure boundaries is demon­strated with the example of a typical reactor pressure vessel and critically discussed. Although no method is distinguishable that could give exact failure probabilities, PFM has several addi­tional chances. Upper limits for failure probability may be obtained together with trends for design and operating conditions. Further, PFM can identify the most sensitive parameters, improved control of which would increase reliability. Thus PFM should play a vital role in the analysis of steel pressure boundaries despite all shortcomings. KW - Bruchmechanik KW - probabilistic fracture mechanics KW - PFM Y1 - 2006 ER - TY - JOUR A1 - Staat, Manfred T1 - Problems and Chances for Probabilistic Fracture Mechanics in the Analysis of Steel Pressure Boundary Reliability JF - Technical feasibility and reliability of passive safety systems for nuclear power plants. Proceedings of an Advisory Group Meeting held in Jülich, 21-24 November 1994 Y1 - 1996 N1 - IAEA-TECDOC-920 ; Onlinezugriff erfolgt auf die überarb. Ausg. 2006 SP - 43 EP - 55 CY - Vienna ER - TY - JOUR A1 - Engelmann, Ulrich M. A1 - Pourshahidi, Mohammad Ali A1 - Shalaby, Ahmed A1 - Krause, Hans-Joachim T1 - Probing particle size dependency of frequency mixing magnetic detection with dynamic relaxation simulation JF - Journal of Magnetism and Magnetic Materials N2 - Biomedical applications of magnetic nanoparticles (MNP) fundamentally rely on the particles’ magnetic relaxation as a response to an alternating magnetic field. The magnetic relaxation complexly depends on the interplay of MNP magnetic and physical properties with the applied field parameters. It is commonly accepted that particle core size is a major contributor to signal generation in all the above applications, however, most MNP samples comprise broad distribution spanning nm and more. Therefore, precise knowledge of the exact contribution of individual core sizes to signal generation is desired for optimal MNP design generally for each application. Specifically, we present a magnetic relaxation simulation-driven analysis of experimental frequency mixing magnetic detection (FMMD) for biosensing to quantify the contributions of individual core size fractions towards signal generation. Applying our method to two different experimental MNP systems, we found the most dominant contributions from approx. 20 nm sized particles in the two independent MNP systems. Additional comparison between freely suspended and immobilized MNP also reveals insight in the MNP microstructure, allowing to use FMMD for MNP characterization, as well as to further fine-tune its applicability in biosensing. Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.jmmm.2022.169965 SN - 0304-8853 VL - 563 IS - In progress, Art. No. 169965 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Kern, Alexander A1 - Dikta, Gerhard T1 - Probability of damage of electrical and electronic systems due to indirect lightning flashes - investigation of data from German insurance companies N2 - In the presented paper data collected from the field related to damage statistics of electrical and electronic apparatus in household are reported and investigated. These damages (total number approx. 74000 cases), registered by five German insurance companies in 2005 and 2006, were adviced by customers as caused by lightning overvoltages. With the use of stochastical methods it is possible, to reasses the collected data and to distinguish between cases, which are with high probability caused by lightning overvoltages, and those, which are not. If there was an indication for a direct strike, this case was excluded, so the focus was only on indirect lightning flashes, i.e. only flashes to ground near the structure and flashes to or nearby an incoming service line were investigated. The data from the field contain the location of damaged apparatus (residence of the policy holder) and the distances of the nearest cloud-to-ground stroke to the location of the damage registered by the German lightning location network BLIDS at the date of damage. The statistical data along with some complementary numerical simulations allow to verify the correspondence of the Standards rules used for IEC 62305-2 with the field data and to define some correction needs. The results could lead to a better understanding whether a damage reported to an insurance company is really caused by indirect lightning, or not. KW - Blitzschutz KW - lightning flash Y1 - 2009 ER - TY - JOUR A1 - Staat, Manfred A1 - Heitzer, M. T1 - Probabilistic limit and shakedown problems JF - Numerical Methods for Limit and Shakedown Analysis. Deterministic and Probabilistic Approach. NIC Series Vol. 15 / Ed. by Staat, M; Heitzer, M. Y1 - 2003 SN - 3-00-010001-6 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - CHAP A1 - Staat, Manfred A1 - Heitzer, Michael ED - Staat, Manfred ED - Heitzer, Michael T1 - Probabilistic limit and shakedown problems T2 - Numerical methods for limit and shakedown analysis. Deterministic and probabilistic problems Y1 - 2003 SN - 3-00-010001-6 N1 - NIC Series VL - 15 SP - 217 EP - 268 PB - John von Neumann Institute for Computing (NIC) CY - Jülich ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Kreißig, R. A1 - Staat, Manfred T1 - Probabilistic limit and shakedown analysis of thin plates and shells JF - Structural safety. 31 (2009), H. 1 Y1 - 2009 SN - 0167-4730 SP - 1 EP - 18 PB - - ER - TY - JOUR A1 - Staat, Manfred T1 - Probabilistic assessment of the fracture mechanics behaviour of an HTR-module primary circuit pressure boundary JF - Nuclear Engineering and Design. 160 (1996), H. 1-2 Y1 - 1996 SN - 0029-5493 SP - 221 EP - 236 ER - TY - JOUR A1 - Digel, Ilya T1 - Primary thermosensory events in cells JF - Transient receptor potential channels / Md. Shahidul Islam, ed. Y1 - 2011 SN - 978-94-007-0264-6 N1 - (Advances in experimental medicine and biology ; 704) SP - 451 EP - 468 PB - Springer CY - Dordrecht [u.a.] ER - TY - CHAP A1 - Abel, Alexander A1 - Pérez-Viana, Daniel A1 - Ciritsis, Bernard A1 - Staat, Manfred ED - Erni, Daniel ED - Fischerauer, Alice ED - Himmel, Jörg ED - Seeger, Thomas ED - Thelen, Klaus T1 - Prevention of femur neck fractures through femoroplasty T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - http://dx.doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 SP - 114 EP - 115 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Rausch, Valentin A1 - Kahmann, Stephanie Lucina A1 - Baltschun, Christoph A1 - Staat, Manfred A1 - Müller, Lars P. A1 - Wegmann, Kilian T1 - Pressure distribution to the distal biceps tendon at the radial tuberosity: a biomechanical study JF - The Journal of Hand Surgery N2 - Purpose Mechanical impingement at the narrow radioulnar space of the tuberosity is believed to be an etiological factor in the injury of the distal biceps tendon. The aim of the study was to compare the pressure distribution at the proximal radioulnar space between 2 fixation techniques and the intact state. Methods Six right arms and 6 left arms from 5 female and 6 male frozen specimens were used for this study. A pressure transducer was introduced at the height of the radial tuberosity with the intact distal biceps tendon and after 2 fixation methods: the suture-anchor and the cortical button technique. The force (N), maximum pressure (kPa) applied to the radial tuberosity, and the contact area (mm²) of the radial tuberosity with the ulna were measured and differences from the intact tendon were detected from 60° supination to 60° pronation in 15° increments with the elbow in full extension and in 45° and 90° flexion of the elbow. Results With the distal biceps tendon intact, the pressures during pronation were similar regardless of extension and flexion and were the highest at 60° pronation with 90° elbow flexion (23.3 ± 53.5 kPa). After repair of the tendon, the mean peak pressure, contact area, and total force showed an increase regardless of the fixation technique. Highest peak pressures were found using the cortical button technique at 45° flexion of the elbow and 60° pronation. These differences were significantly different from the intact tendon. The contact area was significantly larger in full extension and 15°, 30°, and 60° pronation using the cortical button technique. Conclusions Pressures on the distal biceps tendon at the radial tuberosity increase during pronation, especially after repair of the tendon. Clinical relevance Mechanical impingement could play a role in both the etiology of primary distal biceps tendon ruptures and the complications occurring after fixation of the tendon using certain techniques. Y1 - 2020 U6 - http://dx.doi.org/10.1016/j.jhsa.2020.01.006 SN - 0363-5023 VL - 45 IS - 8 SP - 776.e1 EP - 776.e9 PB - Elsevier CY - Amsterdam ER - TY - INPR A1 - Bornheim, Tobias A1 - Niklas, Grieger A1 - Blaneck, Patrick Gustav A1 - Bialonski, Stephan T1 - Preprint: Speaker attribution in German parliamentary debates with QLoRA-adapted large language models T2 - Journal for Language Technology and Computational Linguistics N2 - The growing body of political texts opens up new opportunities for rich insights into political dynamics and ideologies but also increases the workload for manual analysis. Automated speaker attribution, which detects who said what to whom in a speech event and is closely related to semantic role labeling, is an important processing step for computational text analysis. We study the potential of the large language model family Llama 2 to automate speaker attribution in German parliamentary debates from 2017-2021. We fine-tune Llama 2 with QLoRA, an efficient training strategy, and observe our approach to achieve competitive performance in the GermEval 2023 Shared Task On Speaker Attribution in German News Articles and Parliamentary Debates. Our results shed light on the capabilities of large language models in automating speaker attribution, revealing a promising avenue for computational analysis of political discourse and the development of semantic role labeling systems. Y1 - 2023 U6 - http://dx.doi.org/10.48550/arXiv.2309.09902 N1 - Veröffentlichte Version verfügbar unter: https://doi.org/10.21248/jlcl.37.2024.244 ER - TY - INPR A1 - Ringers, Christa A1 - Bialonski, Stephan A1 - Solovev, Anton A1 - Hansen, Jan N. A1 - Ege, Mert A1 - Friedrich, Benjamin M. A1 - Jurisch-Yaksi, Nathalie T1 - Preprint: Local synchronization of cilia and tissue-scale cilia alignment are sufficient for global metachronal waves T2 - bioRxiv N2 - Motile cilia are hair-like cell extensions present in multiple organs of the body. How cilia coordinate their regular beat in multiciliated epithelia to move fluids remains insufficiently understood, particularly due to lack of rigorous quantification. We combine here experiments, novel analysis tools, and theory to address this knowledge gap. We investigate collective dynamics of cilia in the zebrafish nose, due to its conserved properties with other ciliated tissues and its superior accessibility for non-invasive imaging. We revealed that cilia are synchronized only locally and that the size of local synchronization domains increases with the viscosity of the surrounding medium. Despite the fact that synchronization is local only, we observed global patterns of traveling metachronal waves across the multiciliated epithelium. Intriguingly, these global wave direction patterns are conserved across individual fish, but different for left and right nose, unveiling a chiral asymmetry of metachronal coordination. To understand the implications of synchronization for fluid pumping, we used a computational model of a regular array of cilia. We found that local metachronal synchronization prevents steric collisions and improves fluid pumping in dense cilia carpets, but hardly affects the direction of fluid flow. In conclusion, we show that local synchronization together with tissue-scale cilia alignment are sufficient to generate metachronal wave patterns in multiciliated epithelia, which enhance their physiological function of fluid pumping. Y1 - 2021 U6 - http://dx.doi.org/10.1101/2021.11.23.469646 N1 - Veröffentlicht in eLife 12:e77701 (https://doi.org/10.7554/eLife.77701). ER - TY - INPR A1 - Grieger, Niklas A1 - Mehrkanoon, Siamak A1 - Bialonski, Stephan T1 - Preprint: Data-efficient sleep staging with synthetic time series pretraining T2 - arXiv N2 - Analyzing electroencephalographic (EEG) time series can be challenging, especially with deep neural networks, due to the large variability among human subjects and often small datasets. To address these challenges, various strategies, such as self-supervised learning, have been suggested, but they typically rely on extensive empirical datasets. Inspired by recent advances in computer vision, we propose a pretraining task termed "frequency pretraining" to pretrain a neural network for sleep staging by predicting the frequency content of randomly generated synthetic time series. Our experiments demonstrate that our method surpasses fully supervised learning in scenarios with limited data and few subjects, and matches its performance in regimes with many subjects. Furthermore, our results underline the relevance of frequency information for sleep stage scoring, while also demonstrating that deep neural networks utilize information beyond frequencies to enhance sleep staging performance, which is consistent with previous research. We anticipate that our approach will be advantageous across a broad spectrum of applications where EEG data is limited or derived from a small number of subjects, including the domain of brain-computer interfaces. Y1 - 2024 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Pauly, F. A1 - Schroder, G. A1 - Ziemons, Karl A1 - Sievering, R. A1 - Halling, H. T1 - Preliminary studies of a micro-CT for a combined small animal PET/CT scanner JF - 2001 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - We are developing an X-ray computed tomography (CT) system which will be combined with a high resolution animal PET system. This permits acquisition of both molecular and anatomical images in a single machine. In particular the CT will also be utilized for the quantification of the animal PET data by providing accurate data for attenuation correction. A first prototype has been built using a commercially available plane silicon diode detector. A cone-beam reconstruction provides the images using the Feldkamp algorithm. First measurements with this system have been performed on a mouse. It could be shown that the CT setup fulfils all demands for a high quality image of the skeleton of the mouse. It is also suited for soft tissue measurements. To improve contrast and resolution and to acquire the X-ray energy further development of the system, especially the use of semiconductor detectors and iterative reconstruction algorithms are planned. Y1 - 2002 SN - 1082-3654 SP - 1605 EP - 1606 ER - TY - CHAP A1 - Knott, Thomas C. A1 - Sofronia, Raluca E. A1 - Gerressen, Marcus A1 - Law, Yuen A1 - Davidescu, Arjana A1 - Savii, George G. A1 - Gatzweiler, Karl-Heinz A1 - Staat, Manfred A1 - Kuhlen, Torsten W. T1 - Preliminary bone sawing model for a virtual reality-based training simulator of bilateral sagittal split osteotomy T2 - Biomedical simulation : 6th International Symposium, ISBMS 2014, Strasbourg, France, October 16-17, 2014 : proceedings (Lecture notes in computer science : vol. 8789) N2 - Successful bone sawing requires a high level of skill and experience, which could be gained by the use of Virtual Reality-based simulators. A key aspect of these medical simulators is realistic force feedback. The aim of this paper is to model the bone sawing process in order to develop a valid training simulator for the bilateral sagittal split osteotomy, the most often applied corrective surgery in case of a malposition of the mandible. Bone samples from a human cadaveric mandible were tested using a designed experimental system. Image processing and statistical analysis were used for the selection of four models for the bone sawing process. The results revealed a polynomial dependency between the material removal rate and the applied force. Differences between the three segments of the osteotomy line and between the cortical and cancellous bone were highlighted. KW - Bone sawing KW - virtual reality KW - training simulator Y1 - 2014 SN - 978-3-319-12057-7 (Online) SN - 978-3-319-12056-0 (Print) U6 - http://dx.doi.org/10.1007/978-3-319-12057-7_1 SP - 1 EP - 10 PB - Springer CY - Cham ER - TY - CHAP A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Preface of the Special Issue of I3S 2005 in Jülich (Germany) N2 - International Symposium on Sensor Science, I3S 2005 <3; 2005; Juelich, Germany> In: Sensors 2006, 6, 260-261 ISSN 1424-8220 KW - Biosensor KW - I3S 2005 KW - International Symposium on Sensor Science Y1 - 2006 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:hbz:a96-opus-1365 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Doll, Theodor A1 - Wagner, Patrick T1 - Preface / Doll, Theodor ; Wagner, Patrick ; Schöning, Michael J. JF - physica status solidi (a) . 206 (2009), H. 3 Y1 - 2009 SN - 1862-6319 N1 - Special Issue: Engineering of Functional Interfaces (EnFI 08) SP - 389 EP - 390 ER - TY - JOUR A1 - Engelmann, Ulrich M. A1 - Shasha, Carolyn A1 - Teeman, Eric A1 - Slabu, Iona A1 - Krishnan, Kannan M. T1 - Predicting size-dependent heating efficiency of magnetic nanoparticles from experiment and stochastic Néel-Brown Langevin simulation JF - Journal of Magnetism and Magnetic Materials Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.jmmm.2018.09.041 SN - 0304-8853 VL - 471 IS - 1 SP - 450 EP - 456 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schelthoff, Christof A1 - Basermann, Achim A1 - Reichel, Björn T1 - Preconditioned CG methods for sparse matrices on massively parallel machines / Basermann, A. ; Reichel, B. ; Schelthoff, C. JF - Parallel Computing. 23 (1997), H. 3 Y1 - 1997 SN - 0167-8191 SP - 381 EP - 398 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Ui, Y. A1 - Iwasaki, H. A1 - Näther, Niko A1 - Koudelka-Hep, M. A1 - Schöning, Michael Josef T1 - Potentiometric imaging in a microfluidic channel JF - Biomedizinische Technik. 49 (2004), H. 2 Y1 - 2004 SN - 0932-4666 SP - 998 EP - 999 ER - TY - JOUR A1 - Jayaraman, Chandrasekaran A1 - Mummidisetty, Chaitanya Krishna A1 - Loesch, Alexandra A1 - Kaur, Sandi A1 - Hoppe-Ludwig, Shenan A1 - Staat, Manfred A1 - Jayaraman, Arun T1 - Postural and metabolic benefits of using a forearm support walker in older adults with impairments JF - Archives of Physical Medicine and Rehabilitation Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.apmr.2018.10.001 SN - 0003-9993 VL - Volume 100 IS - Issue 4 SP - 638 EP - 647 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Kozlova, Tatiana V. A1 - Lanzl, Ines M. T1 - Postoperative aqueous outflow in the human eye after glaucoma filtration surgery: biofluidmechanical considerations JF - Biomedizinische Technik = Biomedical Engineering Y1 - 2009 SN - 1862-278X VL - 54 IS - 1 SP - 14 EP - 22 PB - - ER - TY - JOUR A1 - Poghossian, Arshak A1 - Cherstvy, A. A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Possibilities and limitations of label-free detection of DNA hybridization with field-effect-based devices JF - Sensors and Actuators B. 111-112 (2005) Y1 - 2005 SN - 0925-4005 N1 - Eurosensors XVIII 2004 — The 18th European Conference on Solid-State Transducers SP - 470 EP - 480 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Cherstvy, A. A1 - Schöning, Michael Josef T1 - Possibilities and limitations of label-free detection of DNA hybridization with field-effect based devices JF - Digest of technical papers : September 12 - 15, 2004, Rome, Italy, Pontificia Universitas Sancto Thoma Aquinate in Urbe / [conference chairperson: C. Di Natale]. Y1 - 2004 SN - 88-7621-282-5 N1 - Eurosensors ; (18, 2004, Roma) SP - 173 EP - 176 CY - Roma ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Lieder, R. M. A1 - Neskakis, A T1 - Positive parity bands in ¹⁹⁵,¹⁹⁷ Tl JF - Proceedings of the International Conference on Nuclear Structure : Tokyo, Sept. 5 - 10, 1977 / ed. by T. Marumori. - Journal of the Physical Society of Japan ; Vol. 44, 1978 : Suppl. Y1 - 1978 N1 - International Conference on Nuclear Structure <1977, Tokyo> SP - 441 PB - Physical Soc. of Japan CY - Tokyo ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Protic, D. A1 - Krings, T. A1 - Niessen, S. T1 - Position-Sensitive Si(Li) Transmission Detectors for the EXL-Experiments at GSI-Darmstadt. JF - Scientific Report / GSi Gesellschaft für Schwerionenforschung, Darmstadt. 2007 (2007), H. 1 Y1 - 2007 SN - 0174-0814 N1 - Fair-Experiments-31; GSI Report 2007-1, June 2007 ; GSI Scientific Report 2006 SP - 33 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Schöning, Michael Josef A1 - Otto, R. A1 - Furuichi, K. A1 - Mourzina, Y. A1 - Ermelenko, Y. A1 - Iwasaki, H. T1 - Portable light-addressable potentiometric sensor (LAPS) for multisensor applications JF - Sensors and Actuators B. 95 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 352 EP - 356 ER - TY - JOUR A1 - Yoshinobu, T. A1 - Schöning, Michael Josef A1 - Otto, R. A1 - Furuichi, K. A1 - Mourzina, Yu A1 - Ermelenko, Yu A1 - Iwasaki, I. T1 - Portable light-addressable potentiometric sensor (LAPS) for multisensor applications JF - Book of abstracts / ed. by J. Saneistr. Y1 - 2002 SN - 80-01-02576-4 N1 - Eurosensors ; (16, 2002, Praha) SP - 898 EP - 901 PB - Czech Technical University, Faculty of Electrical Engineering, Department of Measurement CY - Prague ER - TY - JOUR A1 - Thust, Marion A1 - Schöning, Michael Josef A1 - Frohnhoff, S. A1 - Arens-Fischer, R. A1 - Kordos, P. A1 - Lüth, H. T1 - Porous silicon as a substrate material for potentiometric biosensors JF - Measurement Science and Technology Y1 - 1996 U6 - http://dx.doi.org/10.1088/0957-0233/7/1/003 VL - 7 IS - 1 SP - 26 EP - 29 ER - TY - JOUR A1 - Ciritsis, Alexander A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Kuhl, Christiane K. A1 - Kraemer, Nils Andreas T1 - Porosity and tissue integration of elastic mesh implants evaluated in vitro and in vivo JF - Journal of Biomedical Materials Research: Part B: Applied Biomaterials N2 - Purpose In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model. Material and Methods Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio). Results In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF. Conclusion The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018. Y1 - 2018 U6 - http://dx.doi.org/10.1002/jbm.b.33877 SN - 1552-4981 VL - 106 IS - 2 SP - 827 EP - 833 PB - Wiley CY - New York, NY ER - TY - JOUR A1 - Maggakis-Kelemen, Christina A1 - Digel, Ilya A1 - Artmann, Gerhard T1 - Polystyrene sulfonate/Polyallylamine hydrochloride microcapsules as potential artificial red blood cells - improvement of capsule flexibility JF - Biomedizinische Technik. 50 (2005), H. Erg.-Bd. 1 Y1 - 2005 SP - 324 EP - 326 ER - TY - JOUR A1 - Forst, Thomas A1 - Karagiannis, E. A1 - Lübben, G. A1 - Hohberg, C. A1 - Schöndorf, T. A1 - Dikta, Gerhard A1 - Drexler, M. A1 - Morcos, M. A1 - Dänschel, W. A1 - Borchert, M. A1 - Pfützner, A. T1 - Pleiotrophic and anti-inflammatory effects of pioglitazone precede the metabolic activity in type 2 diabetic patients with coronary artery disease JF - Atherosclerosis. 197 (2008), H. 1 Y1 - 2008 U6 - http://dx.doi.org/10.1016/j.atherosclerosis.2007.05.006 SN - 0021-9150 SP - 311 EP - 317 ER - TY - JOUR A1 - Kloock, Joachim P. A1 - Moreno, Lia A1 - Bratov, A. A1 - Huachupoma, S. A1 - Xu, J. A1 - Wagner, Torsten A1 - Yoshinobu, T. A1 - Ermolenko, Y. A1 - Vlasov, Y. G. A1 - Schöning, Michael Josef T1 - PLD-prepared cadmium sensors based on chalcogenide glasses —ISFET, LAPS and μISE semiconductor structures JF - Sensors and Actuators B: Chemical. 118 (2006), H. 1-2 Y1 - 2006 SN - 0925-4005 N1 - Eurosensors XIX - Eurosensors XIX - The 19th European Conference on Solid-State Transducers SP - 149 EP - 155 ER - TY - JOUR A1 - Michael, Hackl A1 - Mayer, Katharina A1 - Weber, Mareike A1 - Staat, Manfred A1 - van Riet, Roger A1 - Burkhart, Klau Josef A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - Plate osteosynthesis of proximal ulna fractures : a biomechanical micromotion analysis JF - The journal of hand surgery Y1 - 2017 U6 - http://dx.doi.org/10.1016/j.jhsa.2017.05.014 SN - 0363-5023 VL - 42 IS - 10 SP - 834.e1 EP - 834.e7 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Karamanidis, Kiros A1 - Mademli, Lida A1 - Albracht, Kirsten T1 - Plasticity of the human tendon to short and long-term mechanical loading JF - Exercise and Sport Sciences Reviews Y1 - 2009 U6 - http://dx.doi.org/10.1097/JES.0b013e31819c2e1d SN - 1538-3008 VL - 37 IS - 2 SP - 66 EP - 72 ER - TY - JOUR A1 - Arampatzis, Adamantios A1 - Peper, Andreas A1 - Bierbaum, Stefanie A1 - Albracht, Kirsten T1 - Plasticity of human Achilles tendon mechanical and morphological properties in response to cyclic strain JF - Journal of Biomechanics N2 - The purpose of the current study in combination with our previous published data (Arampatzis et al., 2007) was to examine the effects of a controlled modulation of strain magnitude and strain frequency applied to the Achilles tendon on the plasticity of tendon mechanical and morphological properties. Eleven male adults (23.9±2.2 yr) participated in the study. The participants exercised one leg at low magnitude tendon strain (2.97±0.47%), and the other leg at high tendon strain magnitude (4.72±1.08%) of similar frequency (0.5 Hz, 1 s loading, 1 s relaxation) and exercise volume (integral of the plantar flexion moment over time) for 14 weeks, 4 days per week, 5 sets per session. The exercise volume was similar to the intervention of our earlier study (0.17 Hz frequency; 3 s loading, 3 s relaxation) allowing a direct comparison of the results. Before and after the intervention ankle joint moment has been measured by a dynamometer, tendon–aponeurosis elongation by ultrasound and cross-sectional area of the Achilles tendon by magnet resonance images (MRI). We found a decrease in strain at a given tendon force, an increase in tendon–aponeurosis stiffness and tendon elastic modulus of the Achilles tendon only in the leg exercised at high strain magnitude. The cross-sectional area (CSA) of the Achilles tendon did not show any statistically significant (P>0.05) differences to the pre-exercise values in both legs. The results indicate a superior improvement in tendon properties (stiffness, elastic modulus and CSA) at the low frequency (0.17 Hz) compared to the high strain frequency (0.5 Hz) protocol. These findings provide evidence that the strain magnitude applied to the Achilles tendon should exceed the value, which occurs during habitual activities to trigger adaptational effects and that higher tendon strain duration per contraction leads to superior tendon adaptational responses. Y1 - 2010 U6 - http://dx.doi.org/10.1016/j.jbiomech.2010.08.014 SN - 0021-9290 VL - 43 IS - 16 SP - 3073 EP - 3079 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels JF - Nuclear Engineering and Design. 234 (2004), H. 1-3 Y1 - 2004 SN - 0029-5493 SP - 25 EP - 43 ER - TY - JOUR A1 - Staat, Manfred T1 - Plastic collapse analysis of longitudinally flawed pipes and vessels N2 - Improved collapse loads of thick-walled, crack containing pipes and vessels are suggested. Very deep cracks have a residual strength which is better modelled by a global limit load. In all burst tests, the ductility of pressure vessel steels was sufficiently high whereby the burst pressure could be predicted by limit analysis with no need to apply fracture mechanics. The relative prognosis error increases however, for long and deep defects due to uncertainties of geometry and strength data. KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohr KW - Rohrbruch KW - Druckbehälter KW - Stahl KW - Druckbelastung KW - Druckbeanspruchung KW - Rohrbruch KW - Fehlerstellen KW - pipes KW - vessels KW - load limit KW - burst tests KW - burst pressure KW - flaw Y1 - 2004 ER - TY - JOUR A1 - Artmann, Gerhard A1 - Bäumler, H. A1 - Voigt, A. A1 - Mitlöhner, R. [u.a.] T1 - Plastic behaviour of polyelectrolyte microcapsules derived from colloid templates. Bäumler, H., Artmann, Gerhard Michael; Voigt, A., Mitlöhner, R., Neu, B., Kiesewetter, H. JF - Journal of Microencapsulation. 17 (2000), H. 5 Y1 - 2000 SN - 1464-5246 SP - 651 EP - 655 ER - TY - CHAP A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Nojima, H. A1 - Artmann, Gerhard T1 - Plasma-generated cluster ions' effects on indoor microflora : [abstract] N2 - Recently, SHARP corporation has developed the world’s first "Plasma Cluster Ions® (PCI)" air purification technology, which uses plasma discharge to generate cluster ions. The new Plasma Cluster Device releases positive and negative ions into the air, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. In the past, phenomenological tests on the efficacy of the PCI air purification technology on microbial cells have been conducted. In most cases, it has been shown that PCI demonstrated strongly pronounced killing effects on microorganisms. However, the particular mechanisms of PCI action still have to be uncovered. KW - Clusterion KW - Raumluft KW - Luftreiniger KW - Plasmacluster ion technology KW - Air purification Y1 - 2003 ER - TY - CHAP A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard A1 - Nojima, H. T1 - Plasma cluster ions (PCI) influence on microbial cells viability : [abstract] N2 - Recently, SHARP corporation has developed the world’s first “Plasma Cluster Ions (PCI)” air purification technology, which uses plasma discharge to generate cluster ions. The new plasma cluster device releases into the air positive and negative ions, which are harmless to humans and are able to decompose and deactivate airborne substances by chemical reactions. A lot of phenomenological tests of the PCI air purification technology on microbial cells have been conducted. And, in most cases, it has been shown that PCI demonstrate strongly pronounced killing effect. Although, the particular mechanisms of PCI action are still not evident. We studied variations in resistance to PCI among gram-positive airborne microorganisms, as well as some dose-dependent, spatial, cultural and biochemical properties of PCI action in respect of Staphylococcus spp, Enterococcus spp, Micrococcus spp. KW - Clusterion KW - Raumluft KW - Luftreiniger KW - Plasmacluster ion technology KW - Air purification Y1 - 2003 ER - TY - JOUR A1 - Streun, M. A1 - Beer, S. A1 - Hombach, T. A1 - Jahnke, S. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Minwuyelet, S. A1 - Parl, C. A1 - Roeb, G. A1 - Schurr, U. A1 - Ziemons, Karl T1 - PlanTIS: A positron emission tomograph for imaging 11C transport in plants JF - 2007 IEEE Nuclear Science Symposium Conference Record, Vol. 6 N2 - Plant growth and transport processes are highly dynamic. They are characterized by plant-internal control processes and by strong interactions with the spatially and temporally varying environment. Analysis of structure- function relations of growth and transport in plants will strongly benefit from the development of non-invasive techniques. PlanTIS (Plant Tomographic Imaging System) is designed for non-destructive 3D-imaging of positron emitting radiotracers. It will permit functional analysis of the dynamics of carbon distribution in plants including bulky organs. It will be applicable for screening transport properties of plants to evaluate e.g. temperature adaptation of genetically modified plants. PlanTIS is a PET scanner dedicated to monitor the dynamics of the 11C distribution within a plant while or after assimilation of 11CO2. Front end electronics and data acquisition architecture of the scanner are based on the ClearPETTM system [1]. Four detector modules form one of two opposing detector blocks. Optionally, a hardware coincidence detection between the blocks can be applied. In general the scan duration is rather long (~ 1 hour) compared to the decay time of 11C (20 min). As a result the count rates can vary over a wide range and accurate dead time correction is necessary. Y1 - 2008 SN - 1082-3654 SP - 4110 EP - 4112 ER - TY - JOUR A1 - Bäcker, Matthias A1 - Kramer, F. A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Bratov, A. A1 - Abramova, N. A1 - Schöning, Michael Josef T1 - Planar and 3D interdigitated electrodes for biosensing applications: The impact of a dielectric barrier on the sensor properties JF - Physica Status Solidi (A) - Applications and Materials Science N2 - Planar and three-dimensional (3D) interdigitated electrodes (IDE) with electrode digits separated by an insulating barrier of different heights were electrochemically characterized and compared in terms of their sensing properties. Due to the impact of the surface resistance, both types of IDE structures display a non-linear behavior in low-ionic strength solutions. The experimental data were fitted to an electrical equivalent circuit and interpreted taking into account the surface-charge-governed properties. The effect of a charged polyelectrolyte layer electrostatically assembled onto the sensor surface on the surface resistance in solutions with different KCl concentration is studied. In case of the same electrode footprint, 3D-IDEs show a larger cell constant and a higher sensitivity to molecular adsorption than that of planar IDEs. The obtained results demonstrate the potential of 3D-IDEs as a new transducer structure for a direct label-free sensing of charged molecules. Y1 - 2014 U6 - http://dx.doi.org/10.1002/pssa.201330416 SN - 1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print) VL - 211 IS - 6 SP - 1357 EP - 1363 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Kaminsky, Radoslav A1 - Dumont, K. A1 - Weber, Hans-Joachim A1 - Schroll, M. A1 - Verdonck, P. T1 - PIV validation of blood-heart valve leaflet interaction modelling JF - The International journal of artificial organs. 30 (2007), H. 7 Y1 - 2007 SP - 640 EP - 648 PB - - ER - TY - BOOK A1 - Weber, Hans-Joachim A1 - Kaminsky, Radoslav A1 - Kallweit, Stephan A1 - Simons, Antoine T1 - PIV measurements with high temporal resolution behind artificial heart valves Y1 - 2005 N1 - International Symposium on Particle Image Velocimetry <6, 2005, Pasadena, Calif.> ER - TY - JOUR A1 - Bialonski, Stephan A1 - Caron, David A. A1 - Schloen, Julia A1 - Feudel, Ulrike A1 - Kantz, Holger A1 - Moorthi, Stefanie D. T1 - Phytoplankton dynamics in the Southern California Bight indicate a complex mixture of transport and biology JF - Journal of Plankton Research N2 - The stimulation and dominance of potentially harmful phytoplankton taxa at a given locale and time are determined by local environmental conditions as well as by transport to or from neighboring regions. The present study investigated the occurrence of common harmful algal bloom (HAB) taxa within the Southern California Bight, using cross-correlation functions to determine potential dependencies between HAB taxa and environmental factors, and potential links to algal transport via local hydrography and currents. A simulation study, in which Lagrangian particles were released, was used to assess travel times due to advection by prevailing ocean currents in the bight. Our results indicate that transport of some taxa may be an important mechanism for the expansion of their distributions into other regions, which was supported by mean travel times derived from our simulation study and other literature on ocean currents in the Southern California Bight. In other cases, however, phytoplankton dynamics were rather linked to local environmental conditions, including coastal upwelling events. Overall, our study shows that complex current patterns in the Southern California Bight may contribute significantly to the formation and expansion of HABs in addition to local environmental factors determining the spatiotemporal dynamics of phytoplankton blooms. Y1 - 2016 U6 - http://dx.doi.org/10.1093/plankt/fbv122 SN - 1464-3774 VL - 38 IS - 4 SP - 1077 EP - 1091 PB - Oxford University Press CY - Oxford ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Koshitz, I. N. A1 - Svetlowa, O. V. A1 - Zaseeva, M. V. T1 - Physiological principles of hypotensive therapy of open-angle glaucoma during presbyopic period. Part II Promising algorithms of practical sparing applications / Koshitz, I. N. ; Svetlova, O. V. ; Zaseeva, M. V. ; Shuhaev, S. V. ; Makarov, F. N. ; Kotliar JF - Glaukoma (2006) Y1 - 2006 N1 - Original in Russisch SP - 51 EP - 70 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Koshitz, I. N. A1 - Svetlova, O. V. A1 - Zaseeva, M. V. T1 - Physiological principles of hypotensive therapy of open-angle glaucoma during presbyopic period. Part I Initial theoretical presuppositions, hypotheses and facts / Koshitz, I. N. ; Svetlova, O. V. ; Zaseeva, M. V. ; Shuhaev, S. V. ; Makarov, F. N. ; Kotli JF - Glaukoma (2006) Y1 - 2006 N1 - Original in Russisch SP - 35 EP - 53 PB - - ER - TY - JOUR A1 - Savitskaya, I. S. A1 - Kistaubayeva, A. S. A1 - Digel, Ilya A1 - Shokatayeva, D. H. T1 - Physicochemical and Antibacterial Properties of Composite Films Based on Bacterial Cellulose and Chitosan for Wound Dressing Materials JF - Eurasian Chemico-Technological Journal Y1 - 2017 U6 - http://dx.doi.org/10.18321/ectj670 SN - 2522-4867 VL - 19 IS - 3 SP - 255 EP - 264 ER - TY - JOUR A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Huynh A1 - Staat, Manfred T1 - Physical response of hyperelastic models for composite materials and soft tissues JF - Asia pacific journal on computational engineering Y1 - 2015 U6 - http://dx.doi.org/10.1186/s40540-015-0015-x SN - 2196-1166 VL - 2 IS - 3 (December 2015) SP - 1 EP - 18 ER - TY - CHAP A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Huynh A1 - Staat, Manfred T1 - Physical response of hyperelastic models for composite materials and soft tissues T2 - Advances in Composite Material Y1 - 2017 SN - 978-1-61896-300-0 (Hardcover), 978-1-61896-299-7 (Paperback) N1 - Chapter 5 PB - Scientific Research Publishing CY - Wuhan ER - TY - JOUR A1 - Artmann, Gerhard A1 - Zerlin, Kay A1 - Digel, Ilya A1 - Stadler, Andreas M. T1 - Physical discontinuities at body temperature in human red blood cells / Artmann, GM ; Zerlin, K ; Digel, I ; Stadler, A ; Zaccai, G ; Temiz, AA JF - Tissue Engineering. 13 (2007), H. 7 Y1 - 2007 SN - 1076-3279 N1 - TERMIS-EU Meeting Abstracts London, UK September 4–7, 2007 SP - 1778 EP - 1778 ER - TY - JOUR A1 - Murib, M. S. A1 - Yeap, W. S. A1 - Martens, D. A1 - Liu, X. A1 - Bienstman, P. A1 - Fahlman, M. A1 - Schöning, Michael Josef A1 - Michiels, L. A1 - Haenen, K. A1 - Serpengüzel, A. A1 - Wagner, Patrick T1 - Photonic studies on polymer-coated sapphire-spheres : a model system for biological ligands JF - Sensors and actuators A: Physical N2 - In this study we show an optical biosensor concept, based on elastic light scattering from sapphire microspheres. Transmitted and elastic scattering intensity of the microspheres (radius 500 μm, refractive index 1.77) on an optical fiber half coupler is analyzed at 1510 nm. The 0.43 nm angular mode spacing of the resonances is comparable to the angular mode spacing value estimated using the optical size of the microsphere. The spectral linewidths of the resonances are in the order of 0.01 nm, which corresponds to quality factors of approximately 105. A polydopamine layer is used as a functionalizing agent on sapphire microspherical resonators in view of biosensor implementation. The varying layer thickness on the microsphere is determined as a function of the resonance wavelength shift. It is shown that polymer functionalization has a minor effect on the quality factor. This is a promising step toward the development of an optical biosensor. Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.sna.2014.11.024 SN - 1873-3069 (E-Journal); 0924-4247 (Print) VL - 222 SP - 212 EP - 219 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Murib, Mohammed Sharif A1 - Yeap, Weng-Siang A1 - Martens, Daan A1 - Bienstman, Peter A1 - Ceuninck, Ward de A1 - Grinsven, Bart van A1 - Schöning, Michael Josef A1 - Michiels, Luc A1 - Haenen, Ken A1 - Ameloot, Marcel A1 - Serpengüzel, Ali A1 - Wagner, Patrick T1 - Photonic detection and characterization of DNA using sapphire microspheres JF - Journal of biomedical optics N2 - A microcavity-based deoxyribonucleic acid (DNA) optical biosensor is demonstrated for the first time using synthetic sapphire for the optical cavity. Transmitted and elastic scattering intensity at 1510 nm are analyzed from a sapphire microsphere (radius 500  μm, refractive index 1.77) on an optical fiber half coupler. The 0.43 nm angular mode spacing of the resonances correlates well with the optical size of the sapphire sphere. Probe DNA consisting of a 36-mer fragment was covalently immobilized on a sapphire microsphere and hybridized with a 29-mer target DNA. Whispering gallery modes (WGMs) were monitored before the sapphire was functionalized with DNA and after it was functionalized with single-stranded DNA (ssDNA) and double-stranded DNA (dsDNA). The shift in WGMs from the surface modification with DNA was measured and correlated well with the estimated thickness of the add-on DNA layer. It is shown that ssDNA is more uniformly oriented on the sapphire surface than dsDNA. In addition, it is shown that functionalization of the sapphire spherical surface with DNA does not affect the quality factor (Q≈104) of the sapphire microspheres. The use of sapphire is especially interesting because this material is chemically resilient, biocompatible, and widely used for medical implants. Y1 - 2014 U6 - http://dx.doi.org/10.1117/1.JBO.19.9.097006 SN - 1560-2281 (E-Journal); 1083-3668 (Print) VL - 19 IS - 9 SP - 097006 PB - SPIE CY - Bellingham ER - TY - JOUR A1 - Welden, Rene A1 - Nagamine Komesu, Cindy A. A1 - Wagner, Patrick H. A1 - Schöning, Michael Josef A1 - Wagner, Torsten T1 - Photoelectrochemical enzymatic penicillin biosensor: A proof-of-concept experiment JF - Electrochemical Science Advances N2 - Photoelectrochemical (PEC) biosensors are a rather novel type of biosensors thatutilizelighttoprovideinformationaboutthecompositionofananalyte,enablinglight-controlled multi-analyte measurements. For enzymatic PEC biosensors,amperometric detection principles are already known in the literature. In con-trast, there is only a little information on H+-ion sensitive PEC biosensors. Inthis work, we demonstrate the detection of H+ions emerged by H+-generatingenzymes, exemplarily demonstrated with penicillinase as a model enzyme on atitanium dioxide photoanode. First, we describe the pH sensitivity of the sensorand study possible photoelectrocatalytic reactions with penicillin. Second, weshow the enzymatic PEC detection of penicillin. KW - enzymatic biosensor KW - penicillin KW - penicillinase KW - photoelectrochemistry KW - titanium dioxide photoanode Y1 - 2021 U6 - http://dx.doi.org/10.1002/elsa.202100131 SN - 2698-5977 N1 - Corresponding auhtor: Michael J. Schöning VL - 2 IS - 4 SP - 1 EP - 5 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Ermelenko, Y. A1 - Yoshinobu, T A1 - Mourzina, Y. A1 - Levichev, S. A1 - Furuichi, K. A1 - Vlasov, Y. A1 - Schöning, Michael Josef A1 - Iwasaki, H. T1 - Photocurable membranes for ion-selective light-addressable potentiometric sensors JF - Sensors and Actuators B. 85 (2002), H. 1-2 Y1 - 2002 SN - 0925-4005 SP - 79 EP - 85 ER - TY - JOUR A1 - Arinkin, Vladimir A1 - Digel, Ilya A1 - Porst, Dariusz A1 - Temiz Artmann, Aysegül A1 - Artmann, Gerhard T1 - Phenotyping date palm varieties via leaflet cross-sectional imaging and artificial neural network application JF - BMC bioinformatics N2 - Background True date palms (Phoenix dactylifera L.) are impressive trees and have served as an indispensable source of food for mankind in tropical and subtropical countries for centuries. The aim of this study is to differentiate date palm tree varieties by analysing leaflet cross sections with technical/optical methods and artificial neural networks (ANN). Results Fluorescence microscopy images of leaflet cross sections have been taken from a set of five date palm tree cultivars (Hewlat al Jouf, Khlas, Nabot Soltan, Shishi, Um Raheem). After features extraction from images, the obtained data have been fed in a multilayer perceptron ANN with backpropagation learning algorithm. Conclusions Overall, an accurate result in prediction and differentiation of date palm tree cultivars was achieved with average prediction in tenfold cross-validation is 89.1% and reached 100% in one of the best ANN. Y1 - 2014 U6 - http://dx.doi.org/10.1186/1471-2105-15-55 SN - 1471-2105 VL - 15 IS - 55 SP - 1 EP - 8 ER -