TY - JOUR A1 - Heinze, Daniel A1 - Mang, Thomas A1 - Peter, Karin A1 - Möller, Martin A1 - Weichold, Oliver T1 - Synthesis of low molecular weight poly(vinyl acetate) and its application as plasticizer JF - Journal of applied polymer science N2 - Poly(vinyl acetate), PVAc, with a degree of polymerization Xn = 10 was prepared by chain-transfer radical polymerization using carbon tetrachloride and used as oligomeric plasticizer for commercial PVAc. However, the chlorinated chain ends cause a low thermal stability requiring mild Cl/H substitution. The product exhibits high thermal stability and excellent melt-compounding properties. Blends of oligomeric and commercial PVAc show single glass transition temperatures which decrease with higher oligomer content and exhibit small negative deviations from Fox' linear additivity rule. This indicates plasticization and miscibility being mainly due to entropic effects. Injection-moulded thick specimens show ductile behaviour at oligomer contents >10 wt %, while sheets with a thickness of 0.2–0.5 mm appear flexible already at 7.5 wt %. The oxygen permeability coefficients are an order of magnitude lower than those of low-density polyethylene. Due to the sum of their properties, the plasticized sheets present a promising alternative in the preparation of barrier materials. Y1 - 2014 U6 - http://dx.doi.org/10.1002/app.40226 SN - 1097-4628 (E-Journal); 0021-8995 (Print) VL - 131 IS - 9 SP - Article No. 40226 PB - Wiley CY - New York ER - TY - JOUR A1 - Dikta, Gerhard T1 - Asymptotically efficient estimation under semi-parametric random censorship models JF - Journal of multivariate analysis N2 - We study the estimation of some linear functionals which are based on an unknown lifetime distribution. The observations are assumed to be generated under the semi-parametric random censorship model (SRCM), that is, a random censorship model where the conditional expectation of the censoring indicator given the observation belongs to a parametric family. Under this setup a semi-parametric estimator of the survival function was introduced by the author. If the parametric model assumption is correct, it is known that the estimated functional which is based on this semi-parametric estimator is asymptotically at least as efficient as the corresponding one which rests on the nonparametric Kaplan–Meier estimator. In this paper we show that the estimated functional which is based on this semi-parametric estimator is asymptotically efficient with respect to the class of all regular estimators under this semi-parametric model. Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.jmva.2013.10.002 SN - 1095-7243 (E-Journal); 0047-259X (Print) VL - 124 SP - 10 EP - 24 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kronhardt, Valentina A1 - Alexopoulos, Spiros A1 - Reißel, Martin A1 - Sattler, Johannes, Christoph A1 - Hoffschmidt, Bernhard A1 - Hänel, Matthias A1 - Doerbeck, Till T1 - High-temperature thermal storage system for solar tower power plants with open-volumetric air receiver simulation and energy balancing of a discretized model JF - Energy procedia N2 - This paper describes the modeling of a high-temperature storage system for an existing solar tower power plant with open volumetric receiver technology, which uses air as heat transfer medium (HTF). The storage system model has been developed in the simulation environment Matlab/Simulink®. The storage type under investigation is a packed bed thermal energy storage system which has the characteristics of a regenerator. Thermal energy can be stored and discharged as required via the HTF air. The air mass flow distribution is controlled by valves, and the mass flow by two blowers. The thermal storage operation strategy has a direct and significant impact on the energetic and economic efficiency of the solar tower power plants. Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.egypro.2014.03.094 SN - 1876-6102 (E-Journal) ; 1876-6102 (Print) VL - 49 SP - 870 EP - 877 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Rau, Christoph A1 - Alexopoulos, Spiros A1 - Breitbach, Gerd A1 - Hoffschmidt, Bernhard A1 - Latzke, Markus A1 - Sattler, Johannes, Christoph T1 - Transient simulation of a solar-hybrid tower power plant with open volumetric receiver at the location Barstow JF - Energy procedia : proceedings of the SolarPACES 2013 International Conference N2 - In this work the transient simulations of four hybrid solar tower power plant concepts with open-volumetric receiver technology for a location in Barstow-Daggett, USA, are presented. The open-volumetric receiver uses ambient air as heat transfer fluid and the hybridization is realized with a gas turbine. The Rankine cycle is heated by solar-heated air and/or by the gas turbine's flue gases. The plant can be operated in solar-only, hybrid parallel or combined cycle-only mode as well as in any intermediate load levels where the solar portion can vary between 0 to 100%. The simulated plant is based on the configuration of a solar-hybrid power tower project, which is in planning for a site in Northern Algeria. The meteorological data for Barstow-Daggett was taken from the software meteonorm. The solar power tower simulation tool has been developed in the simulation environment MATLAB/Simulink and is validated. Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.egypro.2014.03.157 SN - 1876-6102 VL - 49 SP - 1481 EP - 1490 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Itabashi, Akinori A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - High-speed chemical imaging inside a microfluidic channel JF - Sensors and actuators. B: Chemical N2 - In this study, a high-speed chemical imaging system was developed for visualization of the interior of a microfluidic channel. A microfluidic channel was constructed on the sensor surface of the light-addressable potentiometric sensor (LAPS), on which the ion concentrations could be measured in parallel at up to 64 points illuminated by optical fibers. The temporal change of pH distribution inside the microfluidic channel was recorded at a maximum rate of 100 frames per second (fps). The high frame rate allowed visualization of moving interfaces and plugs in the channel even at a flow velocity of 111 mm/s, which suggests the feasibility of plug-based microfluidic devices for flow-injection analysis (FIA). Y1 - 2014 U6 - http://dx.doi.org/10.1016/j.snb.2013.12.090 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - 194 SP - 521 EP - 527 PB - Elsevier CY - Amsterdam ER -