TY - JOUR A1 - Grotendorst, Johannes A1 - Scott, Tony C. A1 - Aubert-Frécon, Monique A1 - Andrae, D. A1 - Morgan III, J. D. A1 - Glasser, M. L. T1 - Exchange Energy for Two-Active-Electron Diatomic Systems within the Surface Integral Method / Scott,T. C .; Aubert-Frécon, M. ; Andrae, D. ; Grotendorst, J. ; Morgan III, J. D. ; Glasser, M. L. JF - Applicable Algebra in Engineering, Communication and Computing. 15 (2004), H. 2 Y1 - 2004 SN - 0938-1279 N1 - zugl. Technical Report FZJ-ZAM-IB-2004-02, April 2004, 24 pages SP - 101 EP - 128 ER - TY - JOUR A1 - Lehnertz, Klaus A1 - Mormann, Florian A1 - Osterhage, Hannes A1 - Müller, Andy A1 - Prusseit, Jens A1 - Chernihovskyi, Anton A1 - Staniek, Matthäus A1 - Krug, Dieter A1 - Bialonski, Stephan A1 - Elger, Christian E. T1 - State-of-the-art of seizure prediction JF - Journal of Clinical Neurophysiology Y1 - 2007 U6 - https://doi.org/10.1097/WNP.0b013e3180336f16 SN - 1537-1603 VL - 24 IS - 2 SP - 147 EP - 153 ER - TY - JOUR A1 - Arida, Hassan A. A1 - Al-Haddad, Ameera A1 - Schöning, Michael Josef T1 - New Solid-State Organic Membrane Based Lead-Selective Micro-Electrode JF - International Journal of Electrochemical Science. 6 (2011), H. 9 Y1 - 2011 SN - 1452-3981 SP - 3858 EP - 3867 ER - TY - JOUR A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios A1 - Baltzopoulos, Vasilios T1 - Assessment of muscle volume and physiological cross-sectional area of the human triceps surae muscle in vivo JF - Journal of Biomechanics Y1 - 2008 U6 - https://doi.org/10.1016/j.jbiomech.2008.04.020 SN - 0021-9290 VL - 41 SP - 2211 EP - 2218 ER - TY - JOUR A1 - Thust, M. A1 - Schöning, Michael Josef A1 - Muchandani, A. A1 - Wang, J. A1 - Arzdorf, Michael A1 - Mulchandani, P. A1 - Chen, W. T1 - Feldeffekt-Enzymsensor zur Detektion von Pestiziden JF - Sensoren für zukünftige Hochtechnologien und Neuentwicklungen für die Verfahrenstechnik / 6. Dresdner Sensor-Symposium, 8. - 10. Dezember 2003, Dresden. Jörg Peter Baselt; Gerald Gerlach (Hg.) Y1 - 2003 SN - 3-935712-92-8 SP - 125 EP - 128 PB - w.e.b.-Univ.-Verl. CY - Dresden ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Arzdorf, Michael A1 - Mulchandani, P. A1 - Chen, W. A1 - Mulchandani, A. T1 - Towards a capacitive enzyme sensor for direct determination of organophosphorus pesticides: Fundamentals studies and aspects of development JF - Sensors. 3 (2003), H. 6 Y1 - 2003 SN - 1424-8220 SP - 119 EP - 127 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Arzdorf, Michael A1 - Mulchandani, P. A1 - Chen, W. A1 - Mulchandani, A. T1 - A capacitive field-effect sensor for the direct determination of organophosphorus pesticides JF - Sensors and Actuators B. 91 (2003), H. 1-3 Y1 - 2003 SN - 0925-4005 SP - 92 EP - 97 ER - TY - JOUR A1 - Mikucki, Jill Ann A1 - Schuler, C. G. A1 - Digel, Ilya A1 - Kowalski, Julia A1 - Tuttle, M. J. A1 - Chua, Michelle A1 - Davis, R. A1 - Purcell, Alicia A1 - Ghosh, D. A1 - Francke, G. A1 - Feldmann, M. A1 - Espe, C. A1 - Heinen, Dirk A1 - Dachwald, Bernd A1 - Clemens, Joachim A1 - Lyons, W. B. A1 - Tulaczyk, S. T1 - Field-Based planetary protection operations for melt probes: validation of clean access into the blood falls, antarctica, englacial ecosystem JF - Astrobiology N2 - Subglacial environments on Earth offer important analogs to Ocean World targets in our solar system. These unique microbial ecosystems remain understudied due to the challenges of access through thick glacial ice (tens to hundreds of meters). Additionally, sub-ice collections must be conducted in a clean manner to ensure sample integrity for downstream microbiological and geochemical analyses. We describe the field-based cleaning of a melt probe that was used to collect brine samples from within a glacier conduit at Blood Falls, Antarctica, for geomicrobiological studies. We used a thermoelectric melting probe called the IceMole that was designed to be minimally invasive in that the logistical requirements in support of drilling operations were small and the probe could be cleaned, even in a remote field setting, so as to minimize potential contamination. In our study, the exterior bioburden on the IceMole was reduced to levels measured in most clean rooms, and below that of the ice surrounding our sampling target. Potential microbial contaminants were identified during the cleaning process; however, very few were detected in the final englacial sample collected with the IceMole and were present in extremely low abundances (∼0.063% of 16S rRNA gene amplicon sequences). This cleaning protocol can help minimize contamination when working in remote field locations, support microbiological sampling of terrestrial subglacial environments using melting probes, and help inform planetary protection challenges for Ocean World analog mission concepts. Y1 - 2023 U6 - https://doi.org/10.1089/ast.2021.0102 SN - 1557-8070 (online) SN - 153-1074 (print) VL - 23 IS - 11 SP - 1165 EP - 1178 PB - Liebert CY - New York, NY ER - TY - JOUR A1 - Mansurov, Zulkhair A. A1 - Jandosov, J. M. A1 - Kerimkulova, A. R. A1 - Azat, S. A1 - Zhubanova, Azhar Achmet A1 - Digel, Ilya A1 - Savistkaya, I. S. A1 - Akimbekov, Nuraly S. A1 - Kistaubaeva, A. S. T1 - Nanostructured carbon materials for biomedical use JF - Eurasian chemico-technological journal : quarterly journal of the International Higher Education Academy of Sciences N2 - One of the priority trends of carbon nanotechnology is creation of nanocomposite systems. Such carbon nanostructured composites were produced using - raw materials based on the products of agricultural waste, such as grape stones, apricot stones, rice husk. These products have a - wide spectrum of application and can be obtained in large quantities. The Institute of Combustion Problems has carried out the work on synthesis of the nanostructured carbon sorbents for multiple applications including the field of biomedicine. The article presents the data on the synthesis and physico-chemical properties of carbonaceous sorbents using physicochemical methods of investigation: separation and purification of biomolecules; isolation of phytohormone - fusicoccin; adsorbent INGO-1 in the form of an adsorption column for blood detoxification, oral (entero) sorbent - INGO-2; the study of efferent and probiotic properties and sorption activity in regard to the lipopolysaccharide (LPS), new biocomposites - based on carbonized rice husk (CRH) and cellular microorganisms; the use of CRH in wound treatment. A new material for blood detoxication (INGO-1) has been obtained. Adsorption of p-cresyl sulfate and indoxyl sulfate has shown that active carbon adsorbent can remove clinically significant level of p-cresyl sulfate and indoxyl sulfate from human plasma. Enterosorbent INGO-2 possesses high adsorption activity in relation to Gram-negative bacteria and their endotoxins. INGO-2 slows down the growth of conditionally pathogenic microorganisms, without having a negative effect on bifido and lactobacteria. The use of enterosorbent INGO-2 for sorption therapy may provide a solution to a complex problem - detoxication of the digestive tract and normalization of the intestinal micro ecology. The immobilized probiotic called "Riso-lact" was registered at the Ministry of Health of the Republic of Kazakhstan as a biologically active food additive. The developed technology is patented and provides production of the medicine in the form of freeze-dried biomass immobilized in vials. Y1 - 2014 U6 - https://doi.org/10.18321/ectj224 SN - 1562-3920 VL - 15 (2013) IS - 3 SP - 209 EP - 217 PB - Institute of Combustion Problems CY - Almaty ER - TY - JOUR A1 - Auffray, Etiennette A1 - Bruyndonckx, P. A1 - Devroede, O. A1 - Fedorov, A. A1 - Ziemons, Karl T1 - The ClearPET project JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - The Crystal Clear Collaboration has designed and is building a high-resolution small animal PET scanner. The design is based on the use of the Hamamatsu R7600-M64 multi-anode photomultiplier tube and a LSO/LuYAP phoswich matrix with one to one coupling between the crystals and the photo-detector. The complete system will have 80 PM tubes in four rings with an inner diameter of 137 mm and an axial field of view of 110 mm. The PM pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. Simulations, and measurements a 2×4 module test set-up predict a spatial resolution of 1.5 mm in the centre of the field of view and a sensitivity of 5.9% for a point source in the centre of the field of view. Y1 - 2004 SN - 0168-9002 N1 - Proceedings of the 2nd International Conference on Imaging Technologies in Biomedical Sciences VL - 527 IS - 1-2 SP - 171 EP - 174 ER - TY - JOUR A1 - Mosset, Jean-Baptiste A1 - Devroede, Olivier A1 - Krieguer, Magalie A1 - Rey, M. A1 - Vieira, J.-M. A1 - Jung, J. H. A1 - Kuntner, Claudia A1 - Streun, Matthias A1 - Ziemons, Karl A1 - Auffray, Etiennette A1 - Sempere-Roldan, P. A1 - Lecoq, Paul A1 - Bruyndonckx, Peter A1 - Loude, Jean-François A1 - Tavernier, Stefaan A1 - Morel, Christian T1 - Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator JF - IEEE Transactions on Nuclear Science N2 - This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 1 SP - 25 EP - 29 ER - TY - JOUR A1 - Ziemons, Karl A1 - Achten, R. A1 - Auffray, Etiennette A1 - Müller-Veggian, Mattea T1 - The ClearPET™ neuro scanner: a dedicated LSO/LuYAP phoswich small animal PET scanner JF - 2004 IEEE Nuclear Science Symposium conference record : Nuclear Science Symposium, Medical Imaging Conference ; 16 - 22 October 2004, Rome, Italy ; [including the Symposium on Nuclear Power System (SNPS), 14th Room Temperature Semiconductor X- and Gamma-Ray Detectors Workshop and special focus workshops] / NPSS, Nuclear & Plasma Sciences Society. Guest ed.: J. Anthony Seibert Y1 - 2004 SN - 1082-3654 N1 - Nuclear Science Symposium Conference Record, 2004 IEEE SP - 2430 EP - 2433 PB - IEEE Operations Center CY - Piscataway, NJ ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, Etiennette A1 - Barbier, R. A1 - Brandenburg, G. A1 - Bruyndonckx, P. T1 - The ClearPET™ project: Development of a 2nd generation high-performance small animal PET scanner JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment N2 - Second generation high-performance PET scanners, called ClearPET™1, have been developed by working groups of the Crystal Clear Collaboration (CCC). High sensitivity and high spatial resolution for the ClearPET camera is achieved by using a phoswich arrangement combining two different types of lutetium-based scintillator materials: LSO from CTI and LuYAP:Ce from the CCC (ISTC project). In a first ClearPET prototype, phoswich arrangements of 8×8 crystals of 2×2×10 mm3 are coupled to multi-channel photomultiplier tubes (Hamamatsu R7600). A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the ring is 120 mm, the axial detector length is 110 mm.The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the exact pulse starting time, which is subsequently used for coincidence detection. The gantry allows rotation of the detector modules around the field of view. Preliminary data shows a correct identification of the crystal layer about (98±1)%. Typically the energy resolution is (23.3±0.5)% for the luyap layer and (15.4±0.4)% for the lso layer. early studies showed the timing resolution of 2 ns FWHM and 4.8 ns FWTM. the intrinsic spatial resolution ranges from 1.37 mm to 1.61 mm full-width of half-maximum (FWHM) with a mean of 1.48 mm FWHM. further improvements in image and energy resolution are expected when the system geometry is fully modeled. Y1 - 2005 SN - 0168-9002 N1 - Proceedings of the 7th International Conference on Inorganic Scintillators and their Use in Scientific and Industrial Applications VL - 537 IS - 1-2 SP - 307 EP - 311 ER - TY - JOUR A1 - Ziemons, Karl A1 - Auffray, Etiennette A1 - Barbier, R. A1 - Brandenburg, G. T1 - The ClearPET TM LSO/LuYAP phoswich scanner: a high performance small animal PET system JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - A 2nd generation high performance small animal PET scanner, called ClearPET™, has been designed and a first prototype is built by working groups of the Crystal Clear Collaboration (CCC). In order to achieve high sensitivity and maintain good uniform spatial resolution over the field of view in high resolution PET systems, it is necessary to extract the depth of interaction (DOI) information and correct for spatial degradation. The design of the first ClearPET™ Demonstrator based on the use of the multi-anode photomultiplier tube (Hamamatsu R7600-M64) and a LSO/LuYAP phoswich matrix. The two crystal layers of 8*8 crystals (2*2*10 mm3) are stacked on each other and mounted without light guide as one to one on the PMT. A unit of four PMTs arranged in-line represents one of 20 sectors of the ring design. The opening diameter of the crystal ring is 137 mm, the axial detector length is 110 mm. The PMT pulses are digitized by free-running ADCs and digital data processing determines the gamma energy, the phoswich layer and even the pulse arrival time. Single gamma interactions are recorded and coincidences are found by software. The gantry allows rotation of the detector modules around the field of view. The measurements have been done using the first LSO/LuYAP detector cassettes. Y1 - 2004 SN - 1082-3654 SP - 1728 EP - 1732 ER -