TY - JOUR A1 - Claer, Mario A1 - Ferrein, Alexander A1 - Schiffer, Stefan T1 - Calibration of a Rotating or Revolving Platform with a LiDAR Sensor JF - Applied Sciences Y1 - 2019 U6 - https://doi.org/10.3390/app9112238 SN - 2076-3417 VL - Volume 9 IS - issue 11, 2238 PB - MDPI CY - Basel ER - TY - JOUR A1 - Ciritsis, Alexander A1 - Horbach, Andreas A1 - Staat, Manfred A1 - Kuhl, Christiane K. A1 - Kraemer, Nils Andreas T1 - Porosity and tissue integration of elastic mesh implants evaluated in vitro and in vivo JF - Journal of Biomedical Materials Research: Part B: Applied Biomaterials N2 - Purpose In vivo, a loss of mesh porosity triggers scar tissue formation and restricts functionality. The purpose of this study was to evaluate the properties and configuration changes as mesh deformation and mesh shrinkage of a soft mesh implant compared with a conventional stiff mesh implant in vitro and in a porcine model. Material and Methods Tensile tests and digital image correlation were used to determine the textile porosity for both mesh types in vitro. A group of three pigs each were treated with magnetic resonance imaging (MRI) visible conventional stiff polyvinylidene fluoride meshes (PVDF) or with soft thermoplastic polyurethane meshes (TPU) (FEG Textiltechnik mbH, Aachen, Germany), respectively. MRI was performed with a pneumoperitoneum at a pressure of 0 and 15 mmHg, which resulted in bulging of the abdomen. The mesh-induced signal voids were semiautomatically segmented and the mesh areas were determined. With the deformations assessed in both mesh types at both pressure conditions, the porosity change of the meshes after 8 weeks of ingrowth was calculated as an indicator of preserved elastic properties. The explanted specimens were examined histologically for the maturity of the scar (collagen I/III ratio). Results In TPU, the in vitro porosity increased constantly, in PVDF, a loss of porosity was observed under mild stresses. In vivo, the mean mesh areas of TPU were 206.8 cm2 (± 5.7 cm2) at 0 mmHg pneumoperitoneum and 274.6 cm2 (± 5.2 cm2) at 15 mmHg; for PVDF the mean areas were 205.5 cm2 (± 8.8 cm2) and 221.5 cm2 (± 11.8 cm2), respectively. The pneumoperitoneum-induced pressure increase resulted in a calculated porosity increase of 8.4% for TPU and of 1.2% for PVDF. The mean collagen I/III ratio was 8.7 (± 0.5) for TPU and 4.7 (± 0.7) for PVDF. Conclusion The elastic properties of TPU mesh implants result in improved tissue integration compared to conventional PVDF meshes, and they adapt more efficiently to the abdominal wall. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 827–833, 2018. Y1 - 2018 U6 - https://doi.org/10.1002/jbm.b.33877 SN - 1552-4981 VL - 106 IS - 2 SP - 827 EP - 833 PB - Wiley CY - New York, NY ER - TY - JOUR A1 - Ciobanu, Octavian A1 - Staat, Manfred A1 - Rahimi, Alireza T1 - The use of open source software in biomechanical finite element analysis JF - Buletinul Institutului Politehnic din Iaşi / Universitatea Tehnică Gh. Asachi, Iaşi Secţia 5, Construcţii de maşini = Machine construction = Bulletin of the Polytechnic Institute of Jassy = Izvestija Jasskogo Politechničeskogo Instituta Y1 - 2008 SN - 1011-2855 VL - 54 IS - 7/8 SP - 213 EP - 220 ER - TY - JOUR A1 - Chwallek, Constanze A1 - Schuh, Günther A1 - Lorscheider, Bernd T1 - Die virtuelle Fabrik Rhein-Ruhr / Schuh, Günther ; Lorscheider, Bernd ; Chwallek, Constanze JF - Ingenieur-Forum Westfalen-Ruhr (2001) Y1 - 2001 SP - 7 EP - 7 ER - TY - JOUR A1 - Chwallek, Constanze A1 - Nawrath, Lara A1 - Krastina, Anzelika A1 - Bruksle, Ieva T1 - Supportive research on sustainable entrepreneurship and business practices JF - SECA Sustainable Entrepreneurship for Climate Action Y1 - 2024 SN - 978-952-316-514-4 (pdf) SN - 2954-1654 (on-line publication) IS - 3 PB - Lapland University of Applied Sciences Ltd CY - Rovaniemi ER - TY - JOUR A1 - Chwallek, Constanze A1 - Frohn, Sandra T1 - Den Mitarbeitern den Rücken stärken JF - Personalwirtschaft N2 - Ein Drittel der Mitarbeiter der Saint-Gobain Glass Deutschland GmbH hat drei Jahre lang regelmäßig seinen Rücken trainiert. Mit Erfolg, wie eine abschließende Evaluation in Zusammenarbeit mit der FH Aachen zeigt. Die Fehltage der Trainingsteilnehmer sind enorm zurückgegangen, während die untrainierten Kollegen weiterhin unter Rückenbeschwerden leiden. Y1 - 2016 SN - 0341-4698 IS - 5 SP - 46 EP - 48 PB - F.A.Z. Business Media CY - Frankfurt a.M. ER - TY - JOUR A1 - Chwallek, Constanze A1 - Felden, Brigit T1 - Wachstumsfinanzierung in der Nachgründungsphase / Chwallek, Constanze ; Felden, Birgit JF - Finanz-Betrieb : FB ; Zeitschrift für Unternehmensfinanzierung und Finanzmanagement. 8 (2006), H. 10 Y1 - 2006 SN - 1437-8981 SP - 664 EP - 675 ER - TY - JOUR A1 - Chwallek, Constanze A1 - Felden, Birgit T1 - Existenzgründung durch Übernahme / Felden, Birgit ; Chwallek, Constanze JF - Finanz-Betrieb : FB ; Zeitschrift für Unternehmensfinanzierung und Finanzmanagement. 8 (2006), H. 6 Y1 - 2006 SN - 1437-8981 SP - 409 EP - 418 ER - TY - JOUR A1 - Chwallek, Constanze A1 - Farzi, T. A1 - Winkelmann, K. A1 - Killich, S. T1 - Etablierung der Dienstleistung Wissensmanagement in vernetzten Organisationsstrukturen / Farzi, T. ; Winkelmann, K. ; Killich, S. ; Hutterer, P. ; Chwallek, C. JF - Kooperation und Arbeit in vernetzten Welten - Tagungsband der GFA Herbstkonferenz 2003 Aachen, 29.September - 01. Oktober 2003, Hrsg.: Luczak, H. Y1 - 2003 SP - 261 EP - 265 PB - Ergonomia Verl. CY - Stuttgart ER - TY - JOUR A1 - Chwallek, Constanze A1 - Engelen, Andreas A1 - Oswald, Monika A1 - Brettel, Malte T1 - Die Wir­kung des Füh­rungs­ver­hal­tens des Top-Ma­nage­ments auf die un­ter­neh­me­ri­sche Ori­en­tie­rung – ein 5-Län­der-Ver­gleich JF - Zfbf : Schmalenbachs Zeitschrift für betriebswirtschaftliche Forschung Y1 - 2012 SN - 0341-2687 IS - 2 SP - 138 EP - 165 PB - Springer Fachmedien CY - Wiesbaden ER - TY - JOUR A1 - Chudoba, Rostislav A1 - Kuhlmann, Wolfram A1 - Butenweg, Christoph T1 - Ein technisches Informationssystem zur Entwicklung von Textilbeton JF - Bauinformatik-Journal : bi-Journal; Zeitschrift für Architekten und Ingenieure Y1 - 2001 SN - 1436-9060 VL - Bd. 4 IS - H. 6 SP - 15 EP - 20 ER - TY - JOUR A1 - Chudoba, Rostislav A1 - Butenweg, Christoph A1 - Peiffer, F. T1 - Technical information system for collaborative material research JF - Advances in engineering software Y1 - 2004 U6 - https://doi.org/10.1016/j.advengsoft.2004.03.021 SN - 1873-5339 (E-Journal); 0965-9978 (Print) VL - Volume 35 IS - Issue 10-11 SP - 747 EP - 756 ER - TY - JOUR A1 - Christoph, Thomas A1 - Bahrenberg, Gregor A1 - Vry, Jean de A1 - Englberger, Werner A1 - Erdmann, Volker A. A1 - Frech, Moritz A1 - Kögel, Babette A1 - Röhl, Thomas A1 - Schiene, Klaus A1 - Schröder, Wolfgang A1 - Seibler, Jost A1 - Kurreck, Jens T1 - Investigation of TRPV1 loss-of-function phenotypes in transgenic shRNA expressing and knockout mice JF - Molecular and Cellular Neuroscience Y1 - 2008 U6 - https://doi.org/10.1016/j.mcn.2007.12.006 SN - 1044-7431 VL - 37 IS - 3 SP - 579 EP - 589 ER - TY - JOUR A1 - Christiaens, P. A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Wagner, Torsten A1 - Bijnens, N. A1 - Williams, O. A. A1 - Daenen, M. A1 - Haenen, K. A1 - Schöning, Michael Josef A1 - Wagner, P. T1 - Nanocrystalline diamond-based field-effect capacitive pH sensor JF - Transducers '07 Eurosensors XXI : digest of technical papers ; the14th International Conference on Solid-State Sensors, Actuators and Microsystems, June 10-14, 2007, Lyon, France / Gilles Delapierre (Ed.) Y1 - 2007 SN - 1-4244-0841-5 N1 - Eurosensors 21, 2007, Lyon ; International Conference on Solid-State Sensors, Actuators and Microsystems 14, 2007, Lyon SP - 1891 EP - 1894 PB - IEEE CY - Piscataway ER - TY - JOUR A1 - Christiaens, P. A1 - Abouzar, Maryam H. A1 - Poghossian, Arshak A1 - Wagner, Torsten A1 - Bijnens, N. A1 - Williams, O. A. A1 - Daenen, M. A1 - Haenen, K. A1 - Douthéret, O. A1 - Haen, J. d´ A1 - Mekhalif, Z. A1 - Schöning, Michael Josef A1 - Wagner, P. T1 - pH sensitivity of nanocrystalline diamond films JF - Physica status solidi (A). 204 (2007), H. 9 Y1 - 2007 SN - 0031-8965 SP - 2925 EP - 2930 ER - TY - JOUR A1 - Christen, Marc A1 - Kowalski, Julia A1 - Bartelt, Perry T1 - RAMMS: Numerical simulation of dense snow avalanches in three-dimensional terrain JF - Cold Regions Science and Technology N2 - Numerical avalanche dynamics models have become an essential part of snow engineering. Coupled with field observations and historical records, they are especially helpful in understanding avalanche flow in complex terrain. However, their application poses several new challenges to avalanche engineers. A detailed understanding of the avalanche phenomena is required to construct hazard scenarios which involve the careful specification of initial conditions (release zone location and dimensions) and definition of appropriate friction parameters. The interpretation of simulation results requires an understanding of the numerical solution schemes and easy to use visualization tools. We discuss these problems by presenting the computer model RAMMS, which was specially designed by the SLF as a practical tool for avalanche engineers. RAMMS solves the depth-averaged equations governing avalanche flow with accurate second-order numerical solution schemes. The model allows the specification of multiple release zones in three-dimensional terrain. Snow cover entrainment is considered. Furthermore, two different flow rheologies can be applied: the standard Voellmy–Salm (VS) approach or a random kinetic energy (RKE) model, which accounts for the random motion and inelastic interaction between snow granules. We present the governing differential equations, highlight some of the input and output features of RAMMS and then apply the models with entrainment to simulate two well-documented avalanche events recorded at the Vallée de la Sionne test site. KW - RAMMS KW - snow KW - avalanche Y1 - 2010 U6 - https://doi.org/10.1016/j.coldregions.2010.04.005 SN - 1872-7441 VL - 63 IS - 1-2 SP - 1 EP - 14 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Christen, Marc A1 - Bartelt, Perry A1 - Kowalski, Julia T1 - Back calculation of the In den Arelen avalanche with RAMMS: Interpretation of model results JF - Annals of Glaciology N2 - Two- and three-dimensional avalanche dynamics models are being increasingly used in hazard-mitigation studies. These models can provide improved and more accurate results for hazard mapping than the simple one-dimensional models presently used in practice. However, two- and three-dimensional models generate an extensive amount of output data, making the interpretation of simulation results more difficult. To perform a simulation in three-dimensional terrain, numerical models require a digital elevation model, specification of avalanche release areas (spatial extent and volume), selection of solution methods, finding an adequate calculation resolution and, finally, the choice of friction parameters. In this paper, the importance and difficulty of correctly setting up and analysing the results of a numerical avalanche dynamics simulation is discussed. We apply the two-dimensional simulation program RAMMS to the 1968 extreme avalanche event In den Arelen. We show the effect of model input variations on simulation results and the dangers and complexities in their interpretation. KW - avalanche Y1 - 2010 SN - 1727-5644 U6 - https://doi.org/10.3189/172756410791386553 VL - 51 IS - 54 SP - 161 EP - 168 PB - Cambridge University Press CY - Cambridge ER - TY - JOUR A1 - Christ, D. A1 - Hollendung, A. A1 - Larue, H. A1 - Parl, C. A1 - Streun, M. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. T1 - Homogenization of the MultiChannel PM gain by inserting light attenuating masks JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - MultiChannel Photomultipliers (PM), like the R7600-00-M64 or R5900-00-M64 from Hamamatsu, are often chosen as photodetectors in high-resolution positron emission tomography (PET). A major problem of this PM is the nonuniform channel gain. In order to solve this problem, light attenuating masks were created. The aim of the masks is a homogenization of the output of all 64 channels using different hole sizes at the channel positions. The hole area, which is individually defined for the different channels, is inversely proportional to the channel gain. The measurements by inserting light attenuating masks improved a homogenization to a ratio of 1:1.2. Y1 - 2004 SN - 1082-3654 SP - 2382 EP - 2385 ER - TY - JOUR A1 - Choi, Chang-Hoon A1 - Felder, Tim A1 - Felder, Jörg A1 - Tellmann, Lutz A1 - Hong, Suk-Min A1 - Wegener, Hans-Peter A1 - Shah, N Jon A1 - Ziemons, Karl T1 - Design, evaluation and comparison of endorectal coils for hybrid MR-PET imaging of the prostate JF - Physics in Medicine & Biology N2 - Prostate cancer is one of the most common cancers among men and its early detection is critical for its successful treatment. The use of multimodal imaging, such as MR-PET, is most advantageous as it is able to provide detailed information about the prostate. However, as the human prostate is flexible and can move into different positions under external conditions, it is important to localise the focused region-of-interest using both MRI and PET under identical circumstances. In this work, we designed five commonly used linear and quadrature radiofrequency surface coils suitable for hybrid MR-PET use in endorectal applications. Due to the endorectal design and the shielded PET insert, the outer face of the coils investigated was curved and the region to be imaged was outside the volume of the coil. The tilting angles of the coils were varied with respect to the main magnetic field direction. This was done to approximate the various positions from which the prostate could be imaged. The transmit efficiencies and safety excitation efficiencies from simulations, together with the signal-to-noise ratios from the MR images were calculated and analysed. Overall, it was found that the overlapped loops driven in quadrature were superior to the other types of coils we tested. In order to determine the effect of the different coil designs on PET, transmission scans were carried out, and it was observed that the differences between attenuation maps with and without the coils were negligible. The findings of this work can provide useful guidance for the integration of such coil designs into MR-PET hybrid systems in the future. Y1 - 2020 U6 - https://doi.org/10.1088/1361-6560/ab87f8 SN - 0031-9155 VL - 65 IS - 11 PB - IOP CY - Bristol ER - TY - JOUR A1 - Chludek, Astrid A1 - Tran, Duc Hung T1 - Der Reformvorschlag des IAS 12 gem. ED/2009/2 - Ein Plädoyer für die Einführung der valuation allowance JF - KoR Zeitschrift für kapitalmarktorientierte Rechnungslegung Y1 - 2018 SN - 1617-8084 IS - 1 SP - 4 EP - 8 PB - Fachmedien Otto Schmidt CY - Düsseldorf ER -