TY - JOUR A1 - Poghossian, Arshak A1 - Abouzar, Maryam H. A1 - Sakkari, M. A1 - Kassab, T. A1 - Han, Y. A1 - Ingebrandt, S. A1 - Offenhäusser, A. A1 - Schöning, Michael Josef T1 - Field-effect sensors for monitoring the layer-by-layer adsorption of charged macromolecules JF - Sensors and Actuators B: Chemical. 118 (2006), H. 1-2 Y1 - 2006 SN - 0925-4005 N1 - Eurosensors XIX - Eurosensors XIX - The 19th European Conference on Solid-State Transducers SP - 163 EP - 170 ER - TY - JOUR A1 - Bialonski, Stephan A1 - Wellmer, Jörg A1 - Elger, Christian E. A1 - Lehnertz, Klaus T1 - Interictal focus localization in neocortical lesional epilepsies with synchronization cluster analysis JF - Epilepsia Y1 - 2006 SN - 0013-9580 VL - 47 SP - 36 ER - TY - JOUR A1 - Mosset, Jean-Baptiste A1 - Devroede, Olivier A1 - Krieguer, Magalie A1 - Rey, M. A1 - Vieira, J.-M. A1 - Jung, J. H. A1 - Kuntner, Claudia A1 - Streun, Matthias A1 - Ziemons, Karl A1 - Auffray, Etiennette A1 - Sempere-Roldan, P. A1 - Lecoq, Paul A1 - Bruyndonckx, Peter A1 - Loude, Jean-François A1 - Tavernier, Stefaan A1 - Morel, Christian T1 - Development of an optimized LSO/LuYAP phoswich detector head for the Lausanne ClearPET demonstrator JF - IEEE Transactions on Nuclear Science N2 - This paper describes the LSO/LuYAP phoswich detector head developed for the ClearPET small animal PET scanner demonstrator that is under construction in Lausanne within the Crystal Clear Collaboration. The detector head consists of a dual layer of 8×8 LSO and LuYAP crystal arrays coupled to a multi-anode photomultiplier tube (Hamamatsu R7600-M64). Equalistion of the LSO/LuYAP light collection is obtained through partial attenuation of the LSO scintillation light using a thin aluminum deposit of 20-35 nm on LSO and appropriate temperature regulation of the phoswich head between 30°C to 60°C. At 511keV, typical FWHM energy resolutions of the pixels of a phoswich head amounts to (28±2)% for LSO and (25±2)% for LuYAP. The LSO versus LuYAP crystal identification efficiency is better than 98%. Six detector modules have been mounted on a rotating gantry. Axial and tangential spatial resolutions were measured up to 4 cm from the scanner axis and compared to Monte Carlo simulations using GATE. FWHM spatial resolution ranges from 1.3 mm on axis to 2.6 mm at 4 cm from the axis. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 1 SP - 25 EP - 29 ER - TY - JOUR A1 - Mang, Thomas A1 - Roosen, C. A1 - Ansorge, Marion A1 - Leitner, W. T1 - Gaining pH-control in water/carbon dioxide biphasic systems / Abstract No. 1038 / Roosen, Ch. ; Ansorge, M. ; Mang, Thomas ; Leitner, W. ; Greiner, L. JF - Green solvents for processes : Lake Constance, Friedrichshafen, Germany, 8 - 11 October 2006 ; book of abstracts / DECHEMA e.V. Y1 - 2006 N1 - DECHEMA, Gesellschaft für Chemische Technik und Biotechnologie ; [Conference] ; ((Friedrichshafen) : 2006.10.08-11) PB - DECHEMA CY - Frankfurt am Main ER - TY - JOUR A1 - Bialonski, Stephan A1 - Lehnertz, Klaus T1 - Identifying phase synchronization clusters in spatially extended dynamical systems JF - Physical Review E Y1 - 2006 U6 - https://doi.org/10.1103/PhysRevE.74.051909 SN - 2470-0053 VL - 74 IS - 5 SP - 051909 ER - TY - JOUR A1 - Eilmann, Britta A1 - Weber, Pascale A1 - Rigling, Andreas A1 - Eckstein, Dieter T1 - Growth reactions of Pinus sylvestris L. and Quercus pubescens Willd. to drought years at a xeric site in Valais, Switzerland JF - Dendrochronologia Y1 - 2006 U6 - https://doi.org/doi:10.1016/j.dendro.2005.10.002 SN - 1612-0051 (Online) SN - 1125-7865 (Print) VL - 23 IS - 3 SP - 121 EP - 132 ER -