TY - JOUR A1 - Topçu, Murat A1 - Madabhushi, Gopal S.P. A1 - Staat, Manfred T1 - A generalized shear-lag theory for elastic stress transfer between matrix and fibres having a variable radius JF - International Journal of Solids and Structures N2 - A generalized shear-lag theory for fibres with variable radius is developed to analyse elastic fibre/matrix stress transfer. The theory accounts for the reinforcement of biological composites, such as soft tissue and bone tissue, as well as for the reinforcement of technical composite materials, such as fibre-reinforced polymers (FRP). The original shear-lag theory proposed by Cox in 1952 is generalized for fibres with variable radius and with symmetric and asymmetric ends. Analytical solutions are derived for the distribution of axial and interfacial shear stress in cylindrical and elliptical fibres, as well as conical and paraboloidal fibres with asymmetric ends. Additionally, the distribution of axial and interfacial shear stress for conical and paraboloidal fibres with symmetric ends are numerically predicted. The results are compared with solutions from axisymmetric finite element models. A parameter study is performed, to investigate the suitability of alternative fibre geometries for use in FRP. KW - Natural fibres KW - Polymer-matrix composites KW - Biocomposites KW - Stress concentrations KW - Finite element analysis Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.ijsolstr.2022.111464 SN - 0020-7683 VL - 239–240 IS - Art. No. 111464 PB - Elsevier CY - New York, NY ER - TY - JOUR A1 - Golland, Alexander T1 - Aufsicht und Rechtsdurchsetzung bei unzulässigem Einsatz von Cookies & Co. unter Geltung des TTDSG JF - DSB Datenschutz-Berater KW - Informationstechnik KW - Rechtsgebiet KW - Datenschutz KW - Bundesrepublik Deutschland Y1 - 2022 SN - 0170-7256 VL - 46 IS - 1 SP - 14 EP - 16 PB - Deutscher Fachverlag GmbH CY - Frankfurt a.M. ER - TY - JOUR A1 - Mandekar, Swati A1 - Holland, Abigail A1 - Thielen, Moritz A1 - Behbahani, Mehdi A1 - Melnykowycz, Mark T1 - Advancing towards Ubiquitous EEG, Correlation of In-Ear EEG with Forehead EEG JF - Sensors N2 - Wearable EEG has gained popularity in recent years driven by promising uses outside of clinics and research. The ubiquitous application of continuous EEG requires unobtrusive form-factors that are easily acceptable by the end-users. In this progression, wearable EEG systems have been moving from full scalp to forehead and recently to the ear. The aim of this study is to demonstrate that emerging ear-EEG provides similar impedance and signal properties as established forehead EEG. EEG data using eyes-open and closed alpha paradigm were acquired from ten healthy subjects using generic earpieces fitted with three custom-made electrodes and a forehead electrode (at Fpx) after impedance analysis. Inter-subject variability in in-ear electrode impedance ranged from 20 kΩ to 25 kΩ at 10 Hz. Signal quality was comparable with an SNR of 6 for in-ear and 8 for forehead electrodes. Alpha attenuation was significant during the eyes-open condition in all in-ear electrodes, and it followed the structure of power spectral density plots of forehead electrodes, with the Pearson correlation coefficient of 0.92 between in-ear locations ELE (Left Ear Superior) and ERE (Right Ear Superior) and forehead locations, Fp1 and Fp2, respectively. The results indicate that in-ear EEG is an unobtrusive alternative in terms of impedance, signal properties and information content to established forehead EEG. KW - in-ear EEG KW - correlation KW - forehead EEG KW - impedance spectroscopy KW - biopotential electrodes Y1 - 2022 U6 - http://dx.doi.org/10.3390/s22041568 SN - 1424-8220 VL - 22 IS - 4 SP - 1 EP - 19 PB - MDPI CY - Basel ER - TY - JOUR A1 - Defosse, Jerome A1 - Kleinschmidt, Joris A1 - Schmutz, Axel A1 - Loop, Torsten A1 - Staat, Manfred A1 - Gatzweiler, Karl-Heinz A1 - Wappler, Frank A1 - Schieren, Mark T1 - Dental strain on maxillary incisors during tracheal intubation with double-lumen tubes and different laryngoscopy techniques - a blinded manikin study JF - Journal of Cardiothoracic and Vascular Anesthesia KW - anaesthetic complications KW - dental trauma KW - difficult airway KW - double-lumen tube intubation KW - videolaryngoscopy Y1 - 2022 U6 - http://dx.doi.org/10.1053/j.jvca.2022.02.017 SN - 1053-0770 VL - 36 IS - 8, Part B SP - 3021 EP - 3027 PB - Elsevier CY - New York, NY ER - TY - JOUR A1 - Rübbelke, Dirk A1 - Vögele, Stefan A1 - Grajewski, Matthias A1 - Zobel, Luzy T1 - Hydrogen-based steel production and global climate protection: An empirical analysis of the potential role of a European cross border adjustment mechanism JF - Journal of Cleaner Production N2 - The European Union's aim to become climate neutral by 2050 necessitates ambitious efforts to reduce carbon emissions. Large reductions can be attained particularly in energy intensive sectors like iron and steel. In order to prevent the relocation of such industries outside the EU in the course of tightening environmental regulations, the establishment of a climate club jointly with other large emitters and alternatively the unilateral implementation of an international cross-border carbon tax mechanism are proposed. This article focuses on the latter option choosing the steel sector as an example. In particular, we investigate the financial conditions under which a European cross border mechanism is capable to protect hydrogen-based steel production routes employed in Europe against more polluting competition from abroad. By using a floor price model, we assess the competitiveness of different steel production routes in selected countries. We evaluate the climate friendliness of steel production on the basis of specific GHG emissions. In addition, we utilize an input-output price model. It enables us to assess impacts of rising cost of steel production on commodities using steel as intermediates. Our results raise concerns that a cross-border tax mechanism will not suffice to bring about competitiveness of hydrogen-based steel production in Europe because the cost tends to remain higher than the cost of steel production in e.g. China. Steel is a classic example for a good used mainly as intermediate for other products. Therefore, a cross-border tax mechanism for steel will increase the price of products produced in the EU that require steel as an input. This can in turn adversely affect competitiveness of these sectors. Hence, the effects of higher steel costs on European exports should be borne in mind and could require the cross-border adjustment mechanism to also subsidize exports. Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.jclepro.2022.135040 SN - 0959-6526 VL - 380 IS - Part 2, Art. Nr.:135040 PB - Elsevier ER - TY - JOUR A1 - Schüller-Ruhl, Aaron A1 - Dinstühler, Leonard A1 - Senger, Thorsten A1 - Bergfeld, Stefan A1 - Ingenhag, Christian A1 - Fleischhaker, Robert ED - Mackenzie, Jacob T1 - Direct fabrication of arbitrary phase masks in optical glass via ultra-short pulsed laser writing of refractive index modifications JF - Applied Physics B N2 - We study the possibility to fabricate an arbitrary phase mask in a one-step laser-writing process inside the volume of an optical glass substrate. We derive the phase mask from a Gerchberg–Saxton-type algorithm as an array and create each individual phase shift using a refractive index modification of variable axial length. We realize the variable axial length by superimposing refractive index modifications induced by an ultra-short pulsed laser at different focusing depth. Each single modification is created by applying 1000 pulses with 15 μJ pulse energy at 100 kHz to a fixed spot of 25 μm diameter and the focus is then shifted axially in steps of 10 μm. With several proof-of-principle examples, we show the feasibility of our method. In particular, we identify the induced refractive index change to about a value of Δn=1.5⋅10−3. We also determine our current limitations by calculating the overlap in the form of a scalar product and we discuss possible future improvements. Y1 - 2022 U6 - http://dx.doi.org/10.1007/s00340-022-07928-2 SN - 1432-0649 (Online) SN - 0946-2171 (Print) N1 - Corresponding author: Robert Fleischhaker VL - 128 IS - Article number: 208 SP - 1 EP - 11 PB - Springer CY - Berlin ER - TY - JOUR A1 - Eggert, Mathias A1 - Kreuzer, Vincent T1 - Sprachsteuerung im Gesundheitswesen – Anforderungen und Auswahl geeigneter Anbieter T1 - Voice control in healthcare—requirements and provider selection JF - HMD Praxis der Wirtschaftsinformatik N2 - Das Gesundheitswesen ist konfrontiert mit steigenden Kosten und einer immer schwieriger werdenden Personalsituation. Zeitgleich versprechen moderne Sprachsteuerungssysteme Prozesse in Arztpraxen und Krankenhäusern zu verschlanken und Vorgänge zu beschleunigen. Dennoch wird derzeit der Einsatz von Sprachsteuerungssystemen in Arztpraxen oder Krankenhäusern nur selten beobachtet, was auch an den besonders strengen Datenschutzauflagen der Datenschutzgrundverordnung (DSGVO) liegt. Darüber hinaus wirft die niedrige Nutzungsrate die Frage nach den konkreten Anforderungen und ihrer Umsetzbarkeit auf, was durch den vorliegenden Beitrag adressiert wird, indem die Ergebnisse von Interviews mit acht medizinischen Fachexperten ausgewertet werden. Ergänzend wird die technische Umsetzbarkeit einzelner Anforderungen mit unterschiedlichen Cloud-Anbietern erprobt. KW - Gesundheitswesen KW - Sprachsteuerung KW - Sprachassistent KW - Anforderungen KW - Umsetzbarkeit Y1 - 2022 SN - 2198-2775 U6 - http://dx.doi.org/10.1365/s40702-022-00919-z SN - 1436-3011 N1 - Corresponding author: Mathias Eggert VL - 59 SP - 1640 EP - 1652 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Bhattarai, Aroj A1 - May, Charlotte Anabell A1 - Staat, Manfred A1 - Kowalczyk, Wojciech A1 - Tran, Thanh Ngoc T1 - Layer-specific damage modeling of porcine large intestine under biaxial tension JF - Bioengineering N2 - The mechanical behavior of the large intestine beyond the ultimate stress has never been investigated. Stretching beyond the ultimate stress may drastically impair the tissue microstructure, which consequently weakens its healthy state functions of absorption, temporary storage, and transportation for defecation. Due to closely similar microstructure and function with humans, biaxial tensile experiments on the porcine large intestine have been performed in this study. In this paper, we report hyperelastic characterization of the large intestine based on experiments in 102 specimens. We also report the theoretical analysis of the experimental results, including an exponential damage evolution function. The fracture energies and the threshold stresses are set as damage material parameters for the longitudinal muscular, the circumferential muscular and the submucosal collagenous layers. A biaxial tensile simulation of a linear brick element has been performed to validate the applicability of the estimated material parameters. The model successfully simulates the biomechanical response of the large intestine under physiological and non-physiological loads. KW - biaxial tensile experiment KW - anisotropy KW - hyperelastic KW - constitutive modeling KW - damage Y1 - 2022 U6 - http://dx.doi.org/10.3390/bioengineering9100528 SN - 2306-5354 N1 - Der Artikel gehört zum Sonderheft "Computational Biomechanics" VL - 9 IS - 10, Early Access SP - 1 EP - 17 PB - MDPI CY - Basel ER - TY - JOUR A1 - Colombo, Daniele A1 - Drira, Slah A1 - Frotscher, Ralf A1 - Staat, Manfred T1 - An element-based formulation for ES-FEM and FS-FEM models for implementation in standard solid mechanics finite element codes for 2D and 3D static analysis JF - International Journal for Numerical Methods in Engineering N2 - Edge-based and face-based smoothed finite element methods (ES-FEM and FS-FEM, respectively) are modified versions of the finite element method allowing to achieve more accurate results and to reduce sensitivity to mesh distortion, at least for linear elements. These properties make the two methods very attractive. However, their implementation in a standard finite element code is nontrivial because it requires heavy and extensive modifications to the code architecture. In this article, we present an element-based formulation of ES-FEM and FS-FEM methods allowing to implement the two methods in a standard finite element code with no modifications to its architecture. Moreover, the element-based formulation permits to easily manage any type of element, especially in 3D models where, to the best of the authors' knowledge, only tetrahedral elements are used in FS-FEM applications found in the literature. Shape functions for non-simplex 3D elements are proposed in order to apply FS-FEM to any standard finite element. KW - distorted element KW - ES-FEM KW - FS-FEM KW - non-simplex S-FEM elements KW - S-FEM Y1 - 2022 U6 - http://dx.doi.org/10.1002/nme.7126 SN - 1097-0207 VL - 124 IS - 2 SP - 402 EP - 433 PB - Wiley CY - Chichester ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Ortner, Marion A1 - Conradi, Anna A1 - Hacker, Patricia A1 - Hauser, Christine A1 - Günthner, Roman A1 - Moser, Michaela A1 - Muggenthaler, Claudia A1 - Diehl-Schmid, Janine A1 - Priller, Josef A1 - Schmaderer, Christoph A1 - Grimmer, Timo T1 - Altered retinal cerebral vessel oscillation frequencies in Alzheimer's disease compatible with impaired amyloid clearance JF - Neurobiology of Aging N2 - Retinal vessels are similar to cerebral vessels in their structure and function. Moderately low oscillation frequencies of around 0.1 Hz have been reported as the driving force for paravascular drainage in gray matter in mice and are known as the frequencies of lymphatic vessels in humans. We aimed to elucidate whether retinal vessel oscillations are altered in Alzheimer's disease (AD) at the stage of dementia or mild cognitive impairment (MCI). Seventeen patients with mild-to-moderate dementia due to AD (ADD); 23 patients with MCI due to AD, and 18 cognitively healthy controls (HC) were examined using Dynamic Retinal Vessel Analyzer. Oscillatory temporal changes of retinal vessel diameters were evaluated using mathematical signal analysis. Especially at moderately low frequencies around 0.1 Hz, arterial oscillations in ADD and MCI significantly prevailed over HC oscillations and correlated with disease severity. The pronounced retinal arterial vasomotion at moderately low frequencies in the ADD and MCI groups would be compatible with the view of a compensatory upregulation of paravascular drainage in AD and strengthen the amyloid clearance hypothesis. KW - Alzheimer's disease KW - Retinal vessel analysis KW - Vasomotions KW - Pulsations KW - Mild cognitive impairment Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.neurobiolaging.2022.08.012 SN - 0197-4580 VL - 120 SP - 117 EP - 127 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Maurischat, Andreas T1 - Algebraic independence of the Carlitz period and its hyperderivatives JF - Journal of Number Theory KW - Drinfeld modules KW - Periods KW - t-modules KW - Transcendence KW - Higher derivations Y1 - 2022 U6 - http://dx.doi.org/10.1016/j.jnt.2022.01.006 SN - 0022-314X VL - 240 SP - 145 EP - 162 PB - Elsevier CY - Orlando, Fla. ER - TY - JOUR A1 - Molinnus, Denise A1 - Janus, Kevin Alexander A1 - Fang, Anyelina C. A1 - Drinic, Aleksander A1 - Achtsnicht, Stefan A1 - Köpf, Marius A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Thick-film carbon electrode deposited onto a biodegradable fibroin substrate for biosensing applications JF - Physica status solidi (a) N2 - This study addresses a proof-of-concept experiment with a biocompatible screen-printed carbon electrode deposited onto a biocompatible and biodegradable substrate, which is made of fibroin, a protein derived from silk of the Bombyx mori silkworm. To demonstrate the sensor performance, the carbon electrode is functionalized as a glucose biosensor with the enzyme glucose oxidase and encapsulated with a silicone rubber to ensure biocompatibility of the contact wires. The carbon electrode is fabricated by means of thick-film technology including a curing step to solidify the carbon paste. The influence of the curing temperature and curing time on the electrode morphology is analyzed via scanning electron microscopy. The electrochemical characterization of the glucose biosensor is performed by amperometric/voltammetric measurements of different glucose concentrations in phosphate buffer. Herein, systematic studies at applied potentials from 500 to 1200 mV to the carbon working electrode (vs the Ag/AgCl reference electrode) allow to determine the optimal working potential. Additionally, the influence of the curing parameters on the glucose sensitivity is examined over a time period of up to 361 days. The sensor shows a negligible cross-sensitivity toward ascorbic acid, noradrenaline, and adrenaline. The developed biocompatible biosensor is highly promising for future in vivo and epidermal applications. KW - biocompatible materials KW - biodegradable electronic devices KW - biosensors KW - carbon electrodes KW - glucose Y1 - 2022 U6 - http://dx.doi.org/10.1002/pssa.202200100 SN - 1862-6319 N1 - Corresponding author: Michael J. Schöning VL - 219 IS - 23 SP - 1 EP - 9 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Lindner, Simon A1 - Burger, René A1 - Rutledge, Douglas N. A1 - Do, Xuan Tung A1 - Rumpf, Jessica A1 - Diehl, Bernd W. K. A1 - Schulze, Margit A1 - Monakhova, Yulia T1 - Is the calibration transfer of multivariate calibration models between high- and low-field NMR instruments possible? A case study of lignin molecular weight JF - Analytical chemistry N2 - Although several successful applications of benchtop nuclear magnetic resonance (NMR) spectroscopy in quantitative mixture analysis exist, the possibility of calibration transfer remains mostly unexplored, especially between high- and low-field NMR. This study investigates for the first time the calibration transfer of partial least squares regressions [weight average molecular weight (Mw) of lignin] between high-field (600 MHz) NMR and benchtop NMR devices (43 and 60 MHz). For the transfer, piecewise direct standardization, calibration transfer based on canonical correlation analysis, and transfer via the extreme learning machine auto-encoder method are employed. Despite the immense resolution difference between high-field and low-field NMR instruments, the results demonstrate that the calibration transfer from high- to low-field is feasible in the case of a physical property, namely, the molecular weight, achieving validation errors close to the original calibration (down to only 1.2 times higher root mean square errors). These results introduce new perspectives for applications of benchtop NMR, in which existing calibrations from expensive high-field instruments can be transferred to cheaper benchtop instruments to economize. Y1 - 2022 SN - 1520-6882 U6 - http://dx.doi.org/10.1021/acs.analchem.1c05125 VL - 94 IS - 9 SP - 3997 EP - 4004 PB - ACS Publications CY - Washington, DC ER - TY - JOUR A1 - Monakhova, Yulia A1 - Diehl, Bernd W.K. T1 - Multinuclear NMR screening of pharmaceuticals using standardization by 2H integral of a deuterated solvent JF - Journal of Pharmaceutical and Biomedical Analysis N2 - NMR standardization approach that uses the 2H integral of deuterated solvent for quantitative multinuclear analysis of pharmaceuticals is described. As a proof of principle, the existing NMR procedure for the analysis of heparin products according to US Pharmacopeia monograph is extended to the determination of Na+ and Cl- content in this matrix. Quantification is performed based on the ratio of a 23Na (35Cl) NMR integral and 2H NMR signal of deuterated solvent, D2O, acquired using the specific spectrometer hardware. As an alternative, the possibility of 133Cs standardization using the addition of Cs2CO3 stock solution is shown. Validation characteristics (linearity, repeatability, sensitivity) are evaluated. A holistic NMR profiling of heparin products can now also be used for the quantitative determination of inorganic compounds in a single analytical run using a single sample. In general, the new standardization methodology provides an appealing alternative for the NMR screening of inorganic and organic components in pharmaceutical products. KW - NMR spectroscopy KW - Inorganic ions KW - Heparin KW - Standardization Y1 - 2022 SN - 0731-7085 U6 - http://dx.doi.org/10.1016/j.jpba.2021.114530 VL - 209 IS - Article number: 114530 PB - Elsevier ER - TY - JOUR A1 - Burger, René A1 - Lindner, Simon A1 - Rumpf, Jessica A1 - Do, Xuan Tung A1 - Diehl, Bernd W.K. A1 - Rehahn, Matthias A1 - Monakhova, Yulia A1 - Schulze, Margit T1 - Benchtop versus high field NMR: Comparable performance found for the molecular weight determination of lignin JF - Journal of Pharmaceutical and Biomedical Analysis N2 - Lignin is a promising renewable biopolymer being investigated worldwide as an environmentally benign substitute of fossil-based aromatic compounds, e.g. for the use as an excipient with antioxidant and antimicrobial properties in drug delivery or even as active compound. For its successful implementation into process streams, a quick, easy, and reliable method is needed for its molecular weight determination. Here we present a method using 1H spectra of benchtop as well as conventional NMR systems in combination with multivariate data analysis, to determine lignin’s molecular weight (Mw and Mn) and polydispersity index (PDI). A set of 36 organosolv lignin samples (from Miscanthus x giganteus, Paulownia tomentosa and Silphium perfoliatum) was used for the calibration and cross validation, and 17 samples were used as external validation set. Validation errors between 5.6% and 12.9% were achieved for all parameters on all NMR devices (43, 60, 500 and 600 MHz). Surprisingly, no significant difference in the performance of the benchtop and high-field devices was found. This facilitates the application of this method for determining lignin’s molecular weight in an industrial environment because of the low maintenance expenditure, small footprint, ruggedness, and low cost of permanent magnet benchtop NMR systems. KW - NMR KW - PLS-regression KW - Molecular weight determination KW - Chemometrics KW - Biomass Y1 - 2022 SN - 0731-7085 U6 - http://dx.doi.org/10.1016/j.jpba.2022.114649 VL - 212 IS - Article number: 114649 PB - Elsevier CY - New York, NY ER - TY - JOUR A1 - Monakhova, Yulia A1 - Soboleva, Polina M. A1 - Fedotova, Elena S. A1 - Musina, Kristina T. A1 - Burmistrova, Natalia A. T1 - Quantum chemical calculations of IR spectra of heparin disaccharide subunits JF - Computational and Theoretical Chemistry N2 - Heparin is a natural polysaccharide, which plays essential role in many biological processes. Alterations in building blocks can modify biological roles of commercial heparin products, due to significant changes in the conformation of the polymer chain. The variability structure of heparin leads to difficulty in quality control using different analytical methods, including infrared (IR) spectroscopy. In this paper molecular modelling of heparin disaccharide subunits was performed using quantum chemistry. The structural and spectral parameters of these disaccharides have been calculated using RHF/6-311G. In addition, over-sulphated chondroitin sulphate disaccharide was studied as one of the most widespread contaminants of heparin. Calculated IR spectra were analyzed with respect to specific structure parameters. IR spectroscopic fingerprint was found to be sensitive to substitution pattern of disaccharide subunits. Vibrational assignments of calculated spectra were correlated with experimental IR spectral bands of native heparin. Chemometrics was used to perform multivariate analysis of simulated spectral data. KW - IR spectroscopy KW - Chemometrics KW - Quantum chemistry KW - Molecular modelling KW - Quality control Y1 - 2022 SN - 2210-271X U6 - http://dx.doi.org/10.1016/j.comptc.2022.113891 VL - 1217 IS - Article number: 113891 PB - Elsevier CY - New York, NY ER - TY - JOUR A1 - Hahn, Geogr W. A1 - Hebel, Christoph A1 - Manz, W. T1 - Die neuen Empfehlungen für Verkehrsnachfragemodellierung im Personenverkehr JF - Straßenverkehrstechnik N2 - Die neu erschienenen „Empfehlungen zum Einsatz von Verkehrsnachfragemodellen für den Personenverkehr“ liefern erstmals als Empfehlungspapier der Forschungsgesellschaft für Straßen- und Verkehrswesen einen umfassenden Überblick zu den verschiedenen Aspekten der Modellierung und geben dem Fachplaner konkrete Hilfestellung für die Konzeption von Nachfragemodellen. Das Empfehlungspapier zielt unter anderem darauf ab, die Erwartungen und das Anspruchsniveau in Hinblick auf Sachgerechtigkeit der Modelle, die erzielbare Modellqualität und den Detaillierungsgrad der Modellaussagen zu harmonisieren. Y1 - 2022 U6 - http://dx.doi.org/10.53184/SVT10-2022-1 SN - 0039-2219 VL - 66 IS - 10 SP - 721 EP - 726 PB - Kirschbaum Verlag GmbH CY - Bonn ER - TY - JOUR A1 - Emig, J. A1 - Hebel, Christoph A1 - Schwark, A. T1 - Einsatzbereiche für Verkehrsnachfragemodelle JF - Straßenverkehrstechnik N2 - In der Praxis bestehen vielfältige Einsatzbereiche für Verkehrsnachfragemodelle. Mit ihnen können Kenngrößen des Verkehrsangebots und der Verkehrsnachfrage für den heutigen Zustand wie auch für zukünftige Zustände bereitgestellt werden, um so die Grundlagen für verkehrsplanerische Entscheidungen zu liefern. Die neuen „Empfehlungen zum Einsatz von Verkehrsnachfragemodellen für den Personenverkehr“ (EVNM-PV) (FGSV 2022) veranschaulichen anhand von typischen Planungsaufgaben, welche differenzierten Anforderungen daraus für die Modellkonzeption und -erstellung resultieren. Vor dem Hintergrund der konkreten Aufgabenstellung sowie deren spezifischer planerischer Anforderungen bildet die abzuleitende Modellspezifikation die verabredete Grundlage zwischen Auftraggeber und Modellersteller für die konkrete inhaltliche, fachliche Ausgestaltung des Verkehrsmodells. Y1 - 2022 U6 - http://dx.doi.org/10.53184/SVT10-2022-2 SN - 0039-2219 VL - 66 IS - 10 SP - 727 EP - 736 PB - Kirschbaum Verlag GmbH CY - Bonn ER - TY - JOUR A1 - Kindmann, Rolf A1 - Kraus, Matthias A1 - Laumann, Jörg A1 - Vette, Jan T1 - Verallgemeinerte Berechnungsmethode für in Beton eingespannte Stahlprofile – Einspanntiefen, Tragfähigkeitsnachweise und Bemessungshilfen JF - Stahlbau N2 - Stützen und Träger aus Stahlprofilen können in Fundamente oder Wände aus Stahlbeton einbetoniert werden. Diese Anschlüsse wirken in der Regel wie Einspannungen, die eine ausreichende Einspanntiefe erfordern. Im Folgenden wird eine verallgemeinerte Berechnungsmethode für in Stahlbetonkonstruktionen eingespannte Stahlprofile aus gewalzten I-Profilen, geschweißten I-Profilen, runden Hohlprofilen, eckigen Hohlprofilen und einzelligen Kastenquerschnitten vorgestellt. Für Beanspruchungen infolge einachsiger Biegung um die starke und schwache Profilachse werden der profilabhängige Ansatz der Betondruckspannungen im Einspannbereich und die Ermittlung der Einspanntiefe behandelt. Unter Berücksichtigung der Normalkraft werden an den maßgebenden Stellen Tragfähigkeitsnachweise für die Stahlprofile geführt. Als Ergänzung zu den Berechnungsformeln werden Bemessungshilfen zur Verfügung gestellt, die die Wahl der mitwirkenden Breiten und der Einspanntiefen erleichtert. KW - Stahlprofile KW - Anschlüsse an Stahlbeton KW - Einspanntiefen KW - Eingespannte Stützen und Träger KW - steel profiles Y1 - 2022 U6 - http://dx.doi.org/10.1002/stab.202200024 SN - 1437-1049 VL - 93 IS - Early View SP - 1 EP - 25 PB - Ernst & Sohn GmbH CY - Berlin ER - TY - JOUR A1 - Molinnus, Denise A1 - Iken, Heiko A1 - Johnen, Anna Lynn A1 - Richstein, Benjamin A1 - Hellmich, Lena A1 - Poghossian, Arshak A1 - Knoch, Joachim A1 - Schöning, Michael Josef T1 - Miniaturized pH-Sensitive Field-Effect Capacitors with Ultrathin Ta₂O₅ Films Prepared by Atomic Layer Deposition JF - physica status solidi (a) applications and materials science N2 - Miniaturized electrolyte–insulator–semiconductor capacitors (EISCAPs) with ultrathin gate insulators have been studied in terms of their pH-sensitive sensor characteristics: three different EISCAP systems consisting of Al–p-Si–Ta2O5(5 nm), Al–p-Si–Si3N4(1 or 2 nm)–Ta2O5 (5 nm), and Al–p-Si–SiO2(3.6 nm)–Ta2O5(5 nm) layer structures are characterized in buffer solution with different pH values by means of capacitance–voltage and constant capacitance method. The SiO2 and Si3N4 gate insulators are deposited by rapid thermal oxidation and rapid thermal nitridation, respectively, whereas the Ta2O5 film is prepared by atomic layer deposition. All EISCAP systems have a clear pH response, favoring the stacked gate insulators SiO2–Ta2O5 when considering the overall sensor characteristics, while the Si3N4(1 nm)–Ta2O5 stack delivers the largest accumulation capacitance (due to the lower equivalent oxide thickness) and a higher steepness in the slope of the capacitance–voltage curve among the studied stacked gate insulator systems. KW - atomic layer deposition KW - capacitive field-effect sensors KW - pH sensors KW - ultrathin gate insulators Y1 - 2022 U6 - http://dx.doi.org/10.1002/pssa.202100660 SN - 1862-6319 VL - 219 IS - 8 PB - Wiley-VCH CY - Weinheim ER -