TY - JOUR A1 - Haj Ayed, A. A1 - Kusterer, K. A1 - Funke, Harald A1 - Keinz, Jan A1 - Striegan, Constantin A1 - Bohn, D. T1 - Improvement study for the dry-low-NOx hydrogen micromix combustion technology JF - Propulsion and power research Y1 - 2015 U6 - https://doi.org/10.1016/j.jppr.2015.07.003 SN - 2212-540X VL - Vol. 4 IS - Iss. 3 SP - 132 EP - 140 ER - TY - JOUR A1 - Cehreli, Ruksan A1 - Akpinar, Hale A1 - Temiz Artmann, Aysegül A1 - Sagol, Ozgul T1 - Effects of Glutamine and Omega-3 Fatty Acids on Erythrocyte Deformability and Oxidative Damage in Rat Model of Enterocolitis JF - Gastroenterology Research Y1 - 2015 U6 - https://doi.org/10.14740/gr683w SN - 1918-2813 VL - 8 IS - 5 SP - 265 EP - 273 ER - TY - JOUR A1 - Fateri, Miranda A1 - Gebhardt, Andreas T1 - Additive manufactured mechanical disentanglement lock JF - RTejournal - Forum für Rapid Technologie Y1 - 2015 U6 - http://nbn-resolving.de/urn/resolver.pl?urn:nbn:de:0009-2-42147 SN - 1614-0923 VL - 12 PB - Fachhochschule Aachen CY - Aachen ER - TY - JOUR A1 - Oberländer, Jan A1 - Jildeh, Zaid B. A1 - Kirchner, Patrick A1 - Wendeler, Luisa A1 - Bromm, Alexander A1 - Iken, Heiko A1 - Wagner, Patrick A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Study of Interdigitated Electrode Arrays Using Experiments and Finite Element Models for the Evaluation of Sterilization Processes JF - Sensors N2 - In this work, a sensor to evaluate sterilization processes with hydrogen peroxide vapor has been characterized. Experimental, analytical and numerical methods were applied to evaluate and study the sensor behavior. The sensor set-up is based on planar interdigitated electrodes. The interdigitated electrode structure consists of 614 electrode fingers spanning over a total sensing area of 20 mm2. Sensor measurements were conducted with and without microbiological spores as well as after an industrial sterilization protocol. The measurements were verified using an analytical expression based on a first-order elliptical integral. A model based on the finite element method with periodic boundary conditions in two dimensions was developed and utilized to validate the experimental findings. Y1 - 2015 U6 - https://doi.org/10.3390/s151026115 SN - 1424-8220 N1 - This article belongs to the Special Issue "Gas Sensors—Designs and Applications" VL - 15 IS - 10 SP - 26115 EP - 26127 PB - MDPI CY - Basel ER - TY - JOUR A1 - Fissabre, Anke A1 - Niethammer, Bernhard T1 - System mit Hülle - Die innovativen Bauten der Steiff-Spielwarenfabrik in Giengen an der Brenz JF - In situ : Zeitschrift für Architekturgeschichte Y1 - 2015 SN - 1866-959X N1 - gedruckt in der Bibliothek Bayernallee unter der Signatur 13 Z 959-2015 VL - 7 IS - 2 SP - 247 EP - 262 PB - Wernersche Verlagsgesellschaft CY - Worms ER - TY - JOUR A1 - Kessler, Julia A1 - Balc, Nicolae A1 - Gebhardt, Andreas A1 - Abbas, Karim T1 - Basic Research on Lattice Structures Focused on the Tensile Strength JF - Applied Mechanics and Materials Y1 - 2015 U6 - https://doi.org/10.4028/www.scientific.net/AMM.808.193 SN - 1662-7482 N1 - MTeM ; October 14-16, 2015, Cluj-Napoca, Romania VL - Vol. 808 SP - 193 EP - 198 PB - Trans Tech Publications CY - Bäch ER - TY - JOUR A1 - Pfaff, Raphael T1 - Praxisnahe Ausbildung im Fach Schienenfahrzeugtechnik JF - Deine Bahn Y1 - 2015 SN - 0172-4479 IS - 8 SP - 52 EP - 55 PB - Eisenbahn-Fachverlag CY - Mainz ER - TY - JOUR A1 - Pfaff, Raphael A1 - Schmidt, Bernd A1 - Pinders, Udo T1 - Energieeffizienz steigern durch Rekuperationseinrichtungen JF - Deine Bahn Y1 - 2015 SN - 0172-4479 IS - 5 SP - 50 EP - 53 PB - Eisenbahn-Fachverlag CY - Mainz ER - TY - JOUR A1 - Dikta, Gerhard A1 - Kühlheim, René A1 - Mendonca, Jorge A1 - Una-Alcarez, Jacobo de T1 - Asymptotic representation of presmoothed Kaplan–Meier integrals with covariates in a semiparametric censorship model JF - Journal of Statistical Planning and Inference Y1 - 2015 U6 - https://doi.org/10.1016/j.jspi.2015.12.001 SN - 0378-3758 VL - Vol. 171 SP - 10 EP - 37 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Reisert, Steffen A1 - Geissler, H. A1 - Weiler, C. A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Multiple sensor-type system for monitoring the microbicidal effectiveness of aseptic sterilisation processes JF - Food control N2 - The present work describes a novel multiple sensor-type system for the real-time analysis of aseptic sterilisation processes employing gaseous hydrogen peroxide (H2O2) as a sterilant. The inactivation kinetics of Bacillus atrophaeus by gaseous H2O2 have been investigated by means of a methodical calibration experiment, taking into account the process variables H2O2 concentration, humidity and gas temperature. It has been found that the microbicidal effectiveness at H2O2 concentrations above 2% v/v is largely determined by the concentration itself, while at lower H2O2 concentrations, the gas temperature and humidity play a leading role. Furthermore, the responses of different types of gas sensors towards the influencing factors of the sterilisation process have been analysed within the same experiment. Based on a correlation established between the inactivation kinetics and the sensor responses, a calorimetric H2O2 sensor and a metal-oxide semiconductor (MOX) sensor have been identified as possible candidates for monitoring the microbicidal effectiveness of aseptic sterilisation processes employing gaseous H2O2. Therefore, two linear models that describe the relationship between sensor response and microbicidal effectiveness have been proposed. Y1 - 2015 U6 - https://doi.org/10.1016/j.foodcont.2014.07.063 SN - 1873-7129 (E-Journal); 0956-7135 (Print) VL - 47 SP - 615 EP - 622 ER - TY - JOUR A1 - Yoshinobu, Tatsuo A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Recent developments of chemical imaging sensor systems based on the principle of the light-addressable potentiometric sensor JF - Sensors and actuators B: Chemical N2 - The light-addressable potentiometric sensor (LAPS) is an electrochemical sensor with a field-effect structure to detect the variation of the Nernst potential at its sensor surface, the measured area on which is defined by illumination. Thanks to this light-addressability, the LAPS can be applied to chemical imaging sensor systems, which can visualize the two-dimensional distribution of a particular target ion on the sensor surface. Chemical imaging sensor systems are expected to be useful for analysis of reaction and diffusion in various electrochemical and biological samples. Recent developments of LAPS-based chemical imaging sensor systems, in terms of the spatial resolution, measurement speed, image quality, miniaturization and integration with microfluidic devices, are summarized and discussed. Y1 - 2015 U6 - https://doi.org/10.1016/j.snb.2014.09.002 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - 207, Part B SP - 926 EP - 932 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Murib, M. S. A1 - Yeap, W. S. A1 - Martens, D. A1 - Liu, X. A1 - Bienstman, P. A1 - Fahlman, M. A1 - Schöning, Michael Josef A1 - Michiels, L. A1 - Haenen, K. A1 - Serpengüzel, A. A1 - Wagner, Patrick T1 - Photonic studies on polymer-coated sapphire-spheres : a model system for biological ligands JF - Sensors and actuators A: Physical N2 - In this study we show an optical biosensor concept, based on elastic light scattering from sapphire microspheres. Transmitted and elastic scattering intensity of the microspheres (radius 500 μm, refractive index 1.77) on an optical fiber half coupler is analyzed at 1510 nm. The 0.43 nm angular mode spacing of the resonances is comparable to the angular mode spacing value estimated using the optical size of the microsphere. The spectral linewidths of the resonances are in the order of 0.01 nm, which corresponds to quality factors of approximately 105. A polydopamine layer is used as a functionalizing agent on sapphire microspherical resonators in view of biosensor implementation. The varying layer thickness on the microsphere is determined as a function of the resonance wavelength shift. It is shown that polymer functionalization has a minor effect on the quality factor. This is a promising step toward the development of an optical biosensor. Y1 - 2015 U6 - https://doi.org/10.1016/j.sna.2014.11.024 SN - 1873-3069 (E-Journal); 0924-4247 (Print) VL - 222 SP - 212 EP - 219 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Fateri, Miranda A1 - Gebhardt, Andreas T1 - Selective Laser Melting of Soda-Lime Glass Powder JF - International Journal of Applied Ceramic Technology Y1 - 2015 U6 - https://doi.org/10.1111/ijac.12338 SN - 1744-7402 VL - 12 IS - 1 SP - 53 EP - 61 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Fateri, Miranda A1 - Gebhardt, Andreas T1 - Process Parameters Development of Selective Laser Melting of Lunar Regolith for On-Site Manufacturing Applications JF - International Journal of Applied Ceramic Technology Y1 - 2015 SN - 1744-7402 U6 - https://doi.org/10.1111/ijac.12326 VL - 12 IS - 1 SP - 46 EP - 52 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Timme, Michael T1 - Kündigung - Die Vorhersehbarkeit eines zukünftigen Eigenbedarfs für den Vermieter JF - Monatsschrift für Deutsches Recht : MDR : Zeitschrift für die Zivilrechts-Praxis Y1 - 2015 SN - 0340-1812 VL - 69 IS - 9 SP - 489 EP - 490 PB - Verlag Dr. Otto Schmidt CY - Köln ER - TY - JOUR A1 - Fissabre, Anke T1 - Konstruktion und Raumform im Kirchenbau der Moderne : Die Längsbinderkirchen von Hans Herkommer JF - In situ : Zeitschrift für Architekturgeschichte Y1 - 2015 SN - 1866-959X VL - 7 IS - 1 SP - 117 EP - 124 PB - Wernersche Verlagsgesellschaft CY - Worms ER - TY - JOUR A1 - Schneider, Wilhelm A1 - Schneider, Bettina A1 - Meinhardt, Kerstin A1 - Kinder, Stephanie T1 - Die Fallstudie : Aufstellung eines Anlagespiegels JF - Das Wirtschaftsstudium : wisu ; Zeitschrift für Ausbildung, Examen, Berufseinstieg und Fortbildung Y1 - 2015 SN - 0340-3084 N1 - Printausgabe in der Bibliothek Eupener Str. unter der Signatur 43 Z 568 VL - 44 IS - 5 PB - Lange CY - Düsseldorf ER - TY - JOUR A1 - Warmer, Johannes A1 - Wagner, Patrick A1 - Schöning, Michael Josef A1 - Kaul, Peter T1 - Detection of triacetone triperoxide using temperature cycled metal-oxide semiconductor gas sensors JF - Physica status solidi (a) Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201431882 SN - 1862-6319 VL - 212 IS - 6 SP - 1289 EP - 1298 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Delle, Lotta E. A1 - Huck, Christina A1 - Bäcker, Matthias A1 - Müller, Frank A1 - Grandthyll, Samuel A1 - Jacobs, Karin A1 - Lilischkis, Rainer A1 - Vu, Xuan T. A1 - Schöning, Michael Josef A1 - Wagner, Patrick A1 - Thoelen, Roland A1 - Weil, Maryam A1 - Ingebrandt, Sven T1 - Impedimetric immunosensor for the detection of histamine based on reduced graphene oxide JF - Physica status solidi (a) Y1 - 2015 U6 - https://doi.org/10.1002/pssa.201431863 SN - 1862-6319 VL - 212 IS - 6 SP - 1327 EP - 1334 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Timme, Michael T1 - Versagung von Pkh trotz Zulassung der Revi­sion wegen grundsätzlicher Bedeutung JF - Neue Juristische Wochenschrift (NJW) Y1 - 2015 SN - 0341-1915 IS - 30 SP - 2173 EP - 2175 PB - Beck CY - München ER -