TY - JOUR A1 - Yoshinobu, Tatsuo A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Recent developments of chemical imaging sensor systems based on the principle of the light-addressable potentiometric sensor JF - Sensors and actuators B: Chemical N2 - The light-addressable potentiometric sensor (LAPS) is an electrochemical sensor with a field-effect structure to detect the variation of the Nernst potential at its sensor surface, the measured area on which is defined by illumination. Thanks to this light-addressability, the LAPS can be applied to chemical imaging sensor systems, which can visualize the two-dimensional distribution of a particular target ion on the sensor surface. Chemical imaging sensor systems are expected to be useful for analysis of reaction and diffusion in various electrochemical and biological samples. Recent developments of LAPS-based chemical imaging sensor systems, in terms of the spatial resolution, measurement speed, image quality, miniaturization and integration with microfluidic devices, are summarized and discussed. Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.snb.2014.09.002 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - 207, Part B SP - 926 EP - 932 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schreiber, Marc A1 - Barkschat, Kai A1 - Kraft, Bodo A1 - Zündorf, Albert T1 - Quick Pad Tagger : An Efficient Graphical User Interface for Building Annotated Corpora with Multiple Annotation Layers JF - Computer Science & Information Technology (CS & IT) Y1 - 2015 SN - 978-1-921987-32-8 U6 - http://dx.doi.org/10.5121/csit.2015.50413 SN - 2231 - 5403 VL - 5 IS - 4 SP - 131 EP - 143 PB - Academy & Industry Research Collaboration Center (AIRCC) ER - TY - JOUR A1 - Paulßen, Elisabeth A1 - Hoehr, Cornelia A1 - Hou, Xinchi A1 - Hanemaayer, Victoire A1 - Zeisler, Stefan A1 - Adam, Michael J. A1 - Ruth, Thomas J. A1 - Celler, Anna A1 - Buckley, Ken A1 - Benard, Francois A1 - Schaffer, Paul T1 - Production of Y-86 and other radiometals for research purposes using a solution target system JF - Nuclear medicine and biology Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.nucmedbio.2015.06.005 SN - 1872-9614 VL - 42 IS - 11 SP - 842 EP - 849 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Fateri, Miranda A1 - Gebhardt, Andreas T1 - Process Parameters Development of Selective Laser Melting of Lunar Regolith for On-Site Manufacturing Applications JF - International Journal of Applied Ceramic Technology Y1 - 2015 SN - 1744-7402 U6 - http://dx.doi.org/10.1111/ijac.12326 VL - 12 IS - 1 SP - 46 EP - 52 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Pfaff, Raphael T1 - Praxisnahe Ausbildung im Fach Schienenfahrzeugtechnik JF - Deine Bahn Y1 - 2015 SN - 0172-4479 IS - 8 SP - 52 EP - 55 PB - Eisenbahn-Fachverlag CY - Mainz ER - TY - JOUR A1 - Duong, Minh Tuan A1 - Nguyen, Nhu Huynh A1 - Staat, Manfred T1 - Physical response of hyperelastic models for composite materials and soft tissues JF - Asia pacific journal on computational engineering Y1 - 2015 U6 - http://dx.doi.org/10.1186/s40540-015-0015-x SN - 2196-1166 VL - 2 IS - 3 (December 2015) SP - 1 EP - 18 ER - TY - JOUR A1 - Murib, M. S. A1 - Yeap, W. S. A1 - Martens, D. A1 - Liu, X. A1 - Bienstman, P. A1 - Fahlman, M. A1 - Schöning, Michael Josef A1 - Michiels, L. A1 - Haenen, K. A1 - Serpengüzel, A. A1 - Wagner, Patrick T1 - Photonic studies on polymer-coated sapphire-spheres : a model system for biological ligands JF - Sensors and actuators A: Physical N2 - In this study we show an optical biosensor concept, based on elastic light scattering from sapphire microspheres. Transmitted and elastic scattering intensity of the microspheres (radius 500 μm, refractive index 1.77) on an optical fiber half coupler is analyzed at 1510 nm. The 0.43 nm angular mode spacing of the resonances is comparable to the angular mode spacing value estimated using the optical size of the microsphere. The spectral linewidths of the resonances are in the order of 0.01 nm, which corresponds to quality factors of approximately 105. A polydopamine layer is used as a functionalizing agent on sapphire microspherical resonators in view of biosensor implementation. The varying layer thickness on the microsphere is determined as a function of the resonance wavelength shift. It is shown that polymer functionalization has a minor effect on the quality factor. This is a promising step toward the development of an optical biosensor. Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.sna.2014.11.024 SN - 1873-3069 (E-Journal); 0924-4247 (Print) VL - 222 SP - 212 EP - 219 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Matcha, Heike ED - Martens, B. T1 - Parametrized Systems: Conceiving of Buildings as Assemblies of Varied Parts JF - Real Time - Proceedings of the 33rd eCAADe Conference - Volume 2, Vienna University of Technology, Vienna, Austria, 16-18 September 2015 Y1 - 2015 SP - 143 EP - 148 ER - TY - JOUR A1 - Taddei, Francesca A1 - Butenweg, Christoph A1 - Klinkel, S. T1 - Parametric investigation of the soil-structure interaction effects on the dynamic behaviour of a shallow foundation supported wind turbine considering a layered soil JF - Wind energy : an international journal for progress and applications in wind power conversion technology Y1 - 2015 U6 - http://dx.doi.org/10.1002/we.1703 SN - 1099-1824 (E-Journal); 1095-4244 (Print) VL - Volume 18 IS - Issue 3 SP - 399 EP - 417 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Bank, Bart L. van de A1 - Orzada, Stephan A1 - Smits, Frits A1 - Lagemaat, Miriam W. A1 - Rodgers, Christopher T. A1 - Bitz, Andreas A1 - Scheenen, Tom W. J. T1 - Optimized (31) P MRS in the human brain at 7 T with a dedicated RF coil setup JF - NMR in Biomedicine Y1 - 2015 U6 - http://dx.doi.org/10.1002/nbm.3422 SN - 1099-1492 VL - 28 IS - 11 SP - 1570 EP - 1578 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Pilas, Johanna A1 - Mariano, K. A1 - Keusgen, M. A1 - Selmer, Thorsten A1 - Schöning, Michael Josef T1 - Optimization of an Enzyme-based Multi-parameter Biosensor for Monitoring Biogas Processes JF - Procedia Engineering Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.proeng.2015.08.702 SN - 1877-7058 N1 - Part of special issue "Eurosensors 2015" VL - 120 SP - 532 EP - 535 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hough, Lindsay B. A1 - Nalwalk, Julia W. A1 - Ding, Xinxin A1 - Scheer, Nico T1 - Opioid Analgesia in P450 Gene Cluster Knockout Mice: A Search for Analgesia-Relevant Isoforms JF - Drug Metabolism and Disposition Y1 - 2015 U6 - http://dx.doi.org/10.1124/dmd.115.065490 SN - 1521-009x VL - 43 IS - 9 SP - 1326 EP - 1330 ER - TY - JOUR A1 - Yang, Peng-Fei A1 - Kriechbaumer, Andreas A1 - Albracht, Kirsten A1 - Sanno, Maximilian A1 - Ganse, Bergita A1 - Koy, Timmo A1 - Shang, Peng A1 - Brüggemann, Gert-Peter A1 - Müller, Lars Peter A1 - Rittweger, Jörn T1 - On the relationship between tibia torsional deformation and regional muscle contractions in habitual human exercises in vivo JF - Journal of Biomechanics Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.jbiomech.2014.12.031 SN - 0021-9290 VL - 48 IS - 3 SP - 456 EP - 464 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Schneider, Felix A1 - Tran, Duc Hung T1 - On the relation between the fair value option and bid-ask spreads: descriptive evidence on the recognition of credit risk changes under IFRS JF - Journal of Business Economics Y1 - 2018 U6 - http://dx.doi.org/10.1007/s11573-015-0776-2 SN - 1861-8928 VL - 85 IS - 9 SP - 1049 EP - 1081 PB - Springer CY - Berlin ER - TY - JOUR A1 - Baringhaus, Ludwig A1 - Gaigall, Daniel T1 - On an independence test approach to the goodness-of-fit problem JF - Journal of Multivariate Analysis N2 - Let X₁,…,Xₙ be independent and identically distributed random variables with distribution F. Assuming that there are measurable functions f:R²→R and g:R²→R characterizing a family F of distributions on the Borel sets of R in the way that the random variables f(X₁,X₂),g(X₁,X₂) are independent, if and only if F∈F, we propose to treat the testing problem H:F∈F,K:F∉F by applying a consistent nonparametric independence test to the bivariate sample variables (f(Xᵢ,Xⱼ),g(Xᵢ,Xⱼ)),1⩽i,j⩽n,i≠j. A parametric bootstrap procedure needed to get critical values is shown to work. The consistency of the test is discussed. The power performance of the procedure is compared with that of the classical tests of Kolmogorov–Smirnov and Cramér–von Mises in the special cases where F is the family of gamma distributions or the family of inverse Gaussian distributions. KW - Goodness-of-fit test KW - Independence test KW - Parametric bootstrap KW - Vapnik–Čhervonenkis class KW - Gamma distribution Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.jmva.2015.05.013 SN - 0047-259X VL - 2015 IS - 140 SP - 193 EP - 208 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Golland, Alexander A1 - Engling, Christoph T1 - Offene und geschlossene WLAN: Rechtliche Hürden bei Betrieb eines öffentlichen Internetzugangs JF - DSB Datenschutz-Berater Y1 - 2015 SN - 0170-7256 VL - 39 IS - 5 SP - 102 EP - 103 PB - Beck CY - Gütersloh ER - TY - JOUR A1 - Oertel, Mario A1 - Bung, Daniel B. T1 - Numerische Strömungssimulationen von Fließgewässern : Praxisanwendungen und zukünftige Entwicklungen JF - Korrespondenz Wasserwirtschaft : KW Y1 - 2015 SN - 1616-430X VL - 8 IS - H. 3 SP - 177 EP - 182 PB - Gesellschaft zur Förderung der Abwassertechnik CY - Hennef ER - TY - JOUR A1 - Reisert, Steffen A1 - Geissler, H. A1 - Weiler, C. A1 - Wagner, P. A1 - Schöning, Michael Josef T1 - Multiple sensor-type system for monitoring the microbicidal effectiveness of aseptic sterilisation processes JF - Food control N2 - The present work describes a novel multiple sensor-type system for the real-time analysis of aseptic sterilisation processes employing gaseous hydrogen peroxide (H2O2) as a sterilant. The inactivation kinetics of Bacillus atrophaeus by gaseous H2O2 have been investigated by means of a methodical calibration experiment, taking into account the process variables H2O2 concentration, humidity and gas temperature. It has been found that the microbicidal effectiveness at H2O2 concentrations above 2% v/v is largely determined by the concentration itself, while at lower H2O2 concentrations, the gas temperature and humidity play a leading role. Furthermore, the responses of different types of gas sensors towards the influencing factors of the sterilisation process have been analysed within the same experiment. Based on a correlation established between the inactivation kinetics and the sensor responses, a calorimetric H2O2 sensor and a metal-oxide semiconductor (MOX) sensor have been identified as possible candidates for monitoring the microbicidal effectiveness of aseptic sterilisation processes employing gaseous H2O2. Therefore, two linear models that describe the relationship between sensor response and microbicidal effectiveness have been proposed. Y1 - 2015 U6 - http://dx.doi.org/10.1016/j.foodcont.2014.07.063 SN - 1873-7129 (E-Journal); 0956-7135 (Print) VL - 47 SP - 615 EP - 622 ER - TY - JOUR A1 - Altherr, Lena A1 - Ederer, Thorsten A1 - Pöttgen, Philipp A1 - Lorenz, Ulf A1 - Pelz, Peter F. ED - Pelz, Peter F. ED - Groche, Peter T1 - Multicriterial optimization of technical systems considering multiple load and availability scenarios JF - Applied Mechanics and Materials N2 - Cheap does not imply cost-effective -- this is rule number one of zeitgeisty system design. The initial investment accounts only for a small portion of the lifecycle costs of a technical system. In fluid systems, about ninety percent of the total costs are caused by other factors like power consumption and maintenance. With modern optimization methods, it is already possible to plan an optimal technical system considering multiple objectives. In this paper, we focus on an often neglected contribution to the lifecycle costs: downtime costs due to spontaneous failures. Consequently, availability becomes an issue. KW - sustainability KW - availability KW - energy efficiency KW - mixed-integer linear programming KW - system synthesis Y1 - 2015 SN - 1660-9336 U6 - http://dx.doi.org/10.4028/www.scientific.net/AMM.807.247 VL - 807 SP - 247 EP - 256 ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Bäcker, Matthias A1 - Reisert, Steffen A1 - Kramer, Friederike A1 - Begoyan, Vardges K. A1 - Buniatyan, Vahe V. A1 - Schöning, Michael Josef T1 - Multi-parameter sensing using high-k oxide of barium strontium titanate JF - Physica status solidi (a) N2 - High-k perovskite oxide of barium strontium titanate (BST) represents a very attractive multi-functional transducer material for the development of (bio-)chemical sensors. In this work, a Si-based sensor chip containing Pt interdigitated electrodes covered with a thin BST layer (485 nm) has been developed for multi-parameter chemical sensing. The chip has been applied for the contactless measurement of the electrolyte conductivity, the detection of adsorbed charged macromolecules (positively charged polyelectrolytes of polyethylenimine) and the concentration of hydrogen peroxide (H2O2) vapor. The experimental results of functional testing of individual sensors are presented. The mechanism of the BST sensitivity to charged polyelectrolytes and H2O2 vapor has been proposed and discussed. Y1 - 2015 U6 - http://dx.doi.org/10.1002/pssa.201431911 SN - 1862-6319 VL - 212 IS - 6 SP - 1259 PB - Wiley CY - Weinheim ER -