TY - JOUR A1 - Frauenrath, Tobias A1 - Fuchs, Katharina A1 - Dieringer, Matthias A. A1 - Özerdem, Celal A1 - Patel, Nishan A1 - Renz, Wolfgang A1 - Greiser, Andreas A1 - Elgeti, Thomas A1 - Niendorf, Thoralf T1 - Detailing the use of magnetohydrodynamic effects for synchronization of MRI with the cardiac cycle: A feasibility study JF - Journal of Magnetic Resonance Imaging N2 - Purpose: To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle. Materials and Methods: The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.05–7.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization. Results: The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs. Conclusion: This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364–372. © 2012 Wiley Periodicals, Inc. Y1 - 2012 U6 - https://doi.org/10.1002/jmri.23634 SN - 1522-2586 VL - 36 IS - 2 SP - 364 EP - 372 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Heuermann, Holger A1 - Stolle, Reinhard A1 - Schiek, Burkhard T1 - Novel Algorithms for FMCW Range Finding with Microwaves. Stolle, R.; Heuermann, H.; Schiek, B. Y1 - 1995 N1 - Conference proceedings / IEEE NTC '95, the Microwave Systems Conference; NTC <1995, Orlando, Fla.> SP - 129 EP - 132 ER - TY - JOUR A1 - Heuermann, Holger A1 - Baumann, F.-M. A1 - Fauth, G. A1 - Albert, M. T1 - Results of Network Analyzer Measurements with Leakage Errors Corrected with the TMS-15-Term Procedure JF - On-Line Moisture Analysis of Raw Coal Y1 - 1994 N1 - 1993 International Symposium on On-Line Analysis of Coal : Vienna ; [proceedings]. SP - 1361 EP - 1364 ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - de Geyer d'Orth, Thibaut A1 - Dieringer, Matthias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Prothmann, Marcel A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla JF - Journal of Cardiovascular Magnetic Resonance N2 - Background To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. Results ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms. Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). Conclusions The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T. KW - Interval Time Series KW - Image Quality Score KW - Image Quality Assessment KW - Sound Pressure Level KW - Cardiovascular Magnetic Resonance Y1 - 2010 U6 - https://doi.org/10.1186/1532-429X-12-67 SN - 1532-429X VL - 12 IS - 1 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Niemüller, Tim A1 - Lakemeyer, Gerhard A1 - Ferrein, Alexander A1 - Reuter, S. A1 - Ewert, D. A1 - Jeschke, S. A1 - Pensky, D. A1 - Karras, Ulrich T1 - Proposal for advancements to the LLSF in 2014 and beyond Y1 - 2013 SP - Publ. online ER - TY - JOUR A1 - Heuermann, Holger A1 - Schiek, Burkhard T1 - Results of Network Analyzer Measurements with Leakage Errors Corrected with the TMS-15-Term Procedure Y1 - 1994 N1 - 1994 IEEE MTT-S International Microwave Symposium digest : May 23 - 27, 1994, San Diego Convention Center, San Diego, California / H. J. Kuno, ed. SP - 1361 EP - 1364 ER - TY - JOUR A1 - Heuermann, Holger T1 - Praezise Streuparametermessungen sind der Schluessel zur Modellierung elektrischer Schaltungen JF - Neues von Rohde & Schwarz (1997) Y1 - 1997 SP - 22 EP - 23 ER - TY - JOUR A1 - Schopp, Christoph A1 - Britun, Nikolay A1 - Vorac, Jan A1 - Synek, Petr A1 - Snyders, Rony A1 - Heuermann, Holger T1 - Thermal and Optical Study on the Frequency Dependence of an Atmospheric Microwave Argon Plasma Jet JF - IEEE Transactions on Plasma Science Y1 - 2019 SN - 1939-9375 VL - 47 IS - 7 SP - 3176 EP - 3181 PB - IEEE CY - New York ER - TY - JOUR A1 - Ritz, Thomas T1 - Mobile CRM-Systeme : Customer Relationship Management zur Unterstützung des Vertriebsaußendienstes JF - Zeitschrift für wirtschaftlichen Fabrikbetrieb : ZWF ; Organ des VDI-Kompetenzfeldes Informationstechnik (VDI-KfIT) Y1 - 2003 SN - 0932-0482 (Print) SN - 0947-0085 (Online) VL - 99 IS - 12 SP - 699 EP - 702 ER - TY - JOUR A1 - Ferrein, Alexander A1 - Jacobs, Stefan A1 - Lakemeyer, Gerhard T1 - Controlling Unreal Tournament 2004 Bots with the logic-based action language Golog / Jacobs, Stefan ; Ferrein, Alexander ; Lakemeyer, Gerhard JF - Proceedings of the First AAAI Conference on Artificial Intelligence and Interactive Digital Entertainment (AIIDE). Y1 - 2005 SP - 151 EP - 152 ER - TY - JOUR A1 - Ferrein, Alexander A1 - Steinbauer, Gerald T1 - Looking back on 20 Years of RoboCup JF - KI - Künstliche Intelligenz Y1 - 2016 U6 - https://doi.org/10.1007/s13218-016-0443-y SN - 1610-1987 VL - 30 IS - 3-4 SP - 321 EP - 323 PB - Springer CY - Berlin ER - TY - JOUR A1 - Ferrein, Alexander A1 - Rens, Gavin A1 - Meyer, Thomas A1 - Lakemeyer, Gerhard T1 - A Logic for Specifying Partially Observable Stochastic Domains / Rens, Gavin ; Meyer, Thomas ; Ferrein, Alexander ; Lakemeyer, Gerhard JF - Proceedings of the Ninth International Workshop pn non-Monotonic Reasoning, Action and Change (NRAC`11) Y1 - 2011 N1 - Technical Report RMIT-TR-11-02 SP - 15 EP - 22 ER - TY - JOUR A1 - Heuermann, Holger A1 - Schiek, Burkhard T1 - Scattering Parameter Measurements of Microstrip Devices using the Double-LNN Calibration Technique JF - Conference proceedings : [Palais des Festivals et des Congrès Cannes, France, 5 - 8 September 1994] Y1 - 1994 SN - 0-9518032-5-5 N1 - European Microwave Conference <24, 1994, Cannes> PB - Nexus Business Communications CY - Swanley ER - TY - JOUR A1 - Wolf, Martin R. A1 - Schlick, Christopher A1 - Springer, J. ED - Miyamoto, Hiroyuki T1 - The use of implicit communication mechanisms in desktop-teleconferencing-systems JF - Proceedings of WWDU '97 Tokyo, Fifth International Scientific Conference on Work with Display Units : November 3 - 5, 1997, Tokyo Y1 - 1997 N1 - International Scientific Conference on Work with Display Units ; International Scientific Conference on Work with Display Units ; (5 ; 1997.11.03-05 ; Tokyo) SP - 193 EP - 194 PB - - CY - Tokyo ER - TY - JOUR A1 - Heuermann, Holger A1 - Holtrup, Stephan T1 - Fundamentals and ignition of a microplasma at 2.45 GHZ / Holtrup, Stephan ; Heuermann, Holger JF - European Microwave Conference, 2009 : EuMC 2009 ; Sept. 29, 2009 - Oct. 1, 2009, Rome, Italy ; part of European Microwave Week (EuMW) / sponsored by EuMA, European Microwave Association ... Endorsed by IEEE Y1 - 2009 SN - 978-1-4244-4748-0 N1 - EuMC 2009 SP - 1607 EP - 1609 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Heuermann, Holger A1 - Erkens, H. T1 - Mixed-Mode Chain Scattering Parameters: Theory and Verification JF - IEEE Transactions on Microwave Theory and Techniques N2 - Chain scattering parameters or T-parameters are a useful tool for calculating cascaded two-ports. With the increasing importance of mixed-mode S-parameters, a need for converting the T-parameters from their unbalanced form into a balanced form emerges for suiting both common and differential mode waves, as well as the mode conversion. This paper presents the derivation of the equations for transformations between mixed-mode S- and T-parameters for a mixed-mode two-port. Although derived in a way very similar to monomode T-parameters, no simplifications were necessary. Measurement results exemplify the quality of the T-parameter transformation under real-life conditions. Y1 - 2007 SN - 0018-9480 U6 - https://doi.org/10.1109/TMTT.2007.902587 VL - 55 IS - 8 SP - 1704 EP - 1708 PB - IEEE CY - New York ER - TY - JOUR A1 - Rens, Gavin A1 - Ferrein, Alexander T1 - Belief-node condensation for online POMDP algorithms N2 - Slightly extended version of the paper accepted at the Robotics and Artificial Intelligence Workshop, a special track of IEEE AFRICON-2013, held in Mauritius, 9-12 September 2013 Y1 - 2013 SP - 1 EP - 7 PB - IEEE CY - New York ER - TY - JOUR A1 - Martin, Conrad A1 - Frauenrath, Tobias A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging JF - European Radiology N2 - Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur. KW - MRI KW - MR safety KW - Magneto alert sensor KW - High field MRI KW - Uktrahigh field MRI Y1 - 2011 U6 - https://doi.org/10.1007/s00330-011-2153-z SN - 1432-1084 VL - 21 SP - 2187 EP - 2192 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Hüning, Felix A1 - Heuermann, Holger A1 - Wache, Franz-Josef T1 - Wireless CAN JF - Etz: Elektrotechnik & Automation N2 - In modernen elektronischen und mechatronischen Systemen, z. B. im industriellen oder automobil Bereich, kommunizieren eingebettete Steuergeräte und Sensoren vielfach über Bussysteme wie CAN oder LIN. Die Kommunikation findet in der Regel drahtgebunden statt, so dass der Kabelbaum für die Kommunikation sehr groß werden kann. Daher ist es naheliegend, Leitungen und dazugehörige Stecker, z. B. für nicht-sicherheitskritische Komfortsysteme, einzusparen und diese durch gerichtete Funkstrecken für kurze Entfernungen zu ersetzen. Somit könnten Komponenten wie ECUs oder Sensoren kabel- und steckerlos in ein Bussystem integriert werden. Zudem ist eine einfache galvanische und mechanische Trennung zu erreichen. Funkübertragung wird bei diesen Bussystemen derzeit nicht eingesetzt, da insbesondere die Echtzeitfähigkeit und die Robustheit der vorhandenen Funksysteme nicht den Anforderungen der Anwendungen entspricht. Zudem sind bestehende Funksysteme wie WLAN oder Bluetooth im Vergleich zur konventionellen Verkabelung teuer und es besteht hierbei die Möglichkeit, dass sie ausspioniert werden können und so sensible Daten entwendet werden können. In dieser Arbeit wird eine alternative Realisierung zu den bestehenden Funksystemen vorgestellt, die aus wenigen Komponenten aufzubauen ist. Es ist eine protokolllose, echtzeitfähige Übertragung möglich und somit die transparente Integration in ein Bussystem wie CAN. Y1 - 2018 SN - 0170-1711 VL - 139 IS - 10 SP - 22 EP - 26 PB - VDE-Verlag CY - Wuppertal ER - TY - JOUR A1 - Heuermann, Holger T1 - Fehlerkorrigierte Mehrtormessungen für frequenzumsetzende Komponenten mit NonLin-S JF - HF-Report : Hochfrequenztechnik, Optoelektronik, Mikrowellentechnik, Kommunikationstechnik. 22 (2008), H. 4 Y1 - 2008 SN - 1431-827X SP - 39 EP - 44 ER -