TY - JOUR A1 - Kobus, Thiele A1 - Bitz, Andreas A1 - Uden, Mark J. van A1 - Lagemaat, Miram W. A1 - Rothgang, Eva A1 - Orzada, Stephan A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - In vivo 31P MR spectroscopic imaging of the human prostate at 7 T: safety and feasibility JF - Magnetic Resonance in Medicine N2 - 31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and Burn:x-wiley:07403194:media:MRM24175:tex2gif-stack-1 measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer. Y1 - 2012 U6 - http://dx.doi.org/10.1002/mrm.24175 SN - 1522-2594 VL - 68 IS - 6 SP - 1683 EP - 1695 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Kowalewski, Paul A1 - Bragard, Michael A1 - Hüning, Felix A1 - De Doncker, Rik W. T1 - An inexpensive Wiegand-sensor-based rotary encoder without rotating magnets for use in electrical drives JF - IEEE Transactions on Instrumentation and Measurement N2 - This paper introduces an inexpensive Wiegand-sensor-based rotary encoder that avoids rotating magnets and is suitable for electrical-drive applications. So far, Wiegand-sensor-based encoders usually include a magnetic pole wheel with rotating permanent magnets. These encoders combine the disadvantages of an increased magnet demand and a limited maximal speed due to the centripetal force acting on the rotating magnets. The proposed approach reduces the total demand of permanent magnets drastically. Moreover, the rotating part is manufacturable from a single piece of steel, which makes it very robust and cheap. This work presents the theoretical operating principle of the proposed approach and validates its benefits on a hardware prototype. The presented proof-of-concept prototype achieves a mechanical resolution of 4.5 ° by using only 4 permanent magnets, 2Wiegand sensors and a rotating steel gear wheel with 20 teeth. KW - Rotary encoder KW - Wiegand sensor Y1 - 2023 U6 - http://dx.doi.org/10.1109/TIM.2023.3326166 SN - 0018-9456 (Print) SN - 1557-9662 (Online) N1 - Early Access SP - 10 Seiten PB - IEEE ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Breyer, Tobias A1 - Kruszona, Stefan A1 - Maderwald, Stefan A1 - Brote, Irina A1 - Gizewski, Elke R. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - A transmit/receive radiofrequency array for imaging the carotid arteries at 7 Tesla: coil design and first in vivo results JF - Investigative Radiology N2 - Objective: To develop a transmit/receive radiofrequency (RF) array for magnetic resonance imaging (MRI) of the carotid arteries at 7 T. The prototype is characterized in numerical simulations and bench measurements, and the feasibility of plaque imaging at 7 T is demonstrated in first in vivo images. Materials and Methods: The RF phased array coil consists of 8 surface loop coils. To allow imaging of both sides of the neck, the RF array is divided into 2 coil clusters, each with 4 overlapping loop elements. For safety validation, numerical computations of the RF field distribution and the corresponding specific absorption rate were performed on the basis of a heterogeneous human body model. To validate the coil model, maps of the transmit B1+ field were compared between simulation and measurement. In vivo images of a healthy volunteer and a patient (ulcerating plaque and a 50% stenosis of the right internal carotid artery) were acquired using a 3-dimensional FLASH sequence with a high isotropic spatial resolution of 0.54 mm as well as using pulse-triggered proton density (PD)/T2-weighted turbo spin echo sequences. Results: Measurements of the S-parameters yielded a reflection and isolation of the coil elements of better than −18 and −13 dB, respectively. Measurements of the g-factor indicated good image quality for parallel imaging acceleration factors up to 2.4. A similar distribution and a very good match of the absolute values were found between the measured and simulated B1+ transmit RF field for the validation of the coil model. In vivo images revealed good signal excitation of both sides of the neck and a high vessel-to-background image contrast for the noncontrast-enhanced 3-dimensional FLASH sequence. Imaging at 7 T could depict the extent of stenosis, and revealed the disruption and ulcer of the plaque. Conclusions: This study demonstrates that 2 four-channel transmit/receive RF arrays for each side of the neck is a suitable concept for in vivo MRI of the carotid arteries at 7 Tesla. Further studies are needed to explore and exploit the full potential of 7 T high-field MRI for carotid atherosclerotic plaque imaging. Y1 - 2011 U6 - http://dx.doi.org/10.1097/RLI.0b013e318206cee4 SN - 1536-0210 VL - 46 IS - 4 SP - 246 EP - 254 PB - Wolters Kluwer CY - Köln ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Dammann, Philipp A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T JF - Medical Physics N2 - Purpose: MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented. Methods: Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping. Results: A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well. Conclusions: This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique. Y1 - 2010 U6 - http://dx.doi.org/10.1118/1.3517176 SN - 2473-4209 VL - 37 IS - 12 SP - 6368 EP - 6376 PB - Wiley CY - Hoboken, NJ ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Kruszona, Stefan A1 - Orzada, Stephan A1 - Schaefer, Lena C. A1 - Theysohn, Jens M. A1 - Maderwald, Stefan A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel phased array RF coil for spine MR imaging at 7 T JF - Investigative Radiology Y1 - 2009 U6 - http://dx.doi.org/10.1097/RLI.0b013e3181b24ab7 SN - 1536-0210 VL - 44 IS - 11 SP - 734 EP - 740 PB - Lippincott Williams & Wilkins ER - TY - JOUR A1 - Kraff, Oliver A1 - Wrede, Karsten H. A1 - Schoemberg, Tobias A1 - Dammann, Philipp A1 - Noureddine, Yacine A1 - Orzada, Stephan A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - MR safety assessment of potential RF heating from cranial fixation plates at 7 T JF - Medical Physics Y1 - 2013 U6 - http://dx.doi.org/10.1118/1.4795347 SN - 2473-4209 VL - 40 IS - 4 SP - 042302-1 EP - 042302-10 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Krause, Gregor T1 - High Field Phenomena of Polymeric Insulation Investigated at PE Needle-Plane Specimen JF - Seventh International Symposium on High Voltage Engineering : Dresden, August 26 - 30, 1991 / Technische Universität Dresden Y1 - 1991 N1 - International Symposium on High Voltage Engineering ; (7, 1991, Dresden); International Symposium on High Voltage Engineering (ISH) ; (7 : ; 1991.08.26-30 : ; Dresden) PB - TU Dresden CY - Dresden ER - TY - JOUR A1 - Krause, Gregor A1 - Fruth, B. T1 - Dielectric Properties of Polyolefins Stressed by High Electrical Fields / Fruth, B. ; Krause, G. JF - Plenary lectures and contributions presented at the International Symposium on Polymer Materials : held in San Sebastian (Donostia), Spain, 31 August - 4 September, 1987 / symposium ed. G. M. Guzmán ; A. Santamaria Y1 - 1988 SN - 3-85739-220-7 N1 - International Symposium on Polymer Materials <1987, San Sebastián, Golfo de Vizcaya> PB - Huethig & Wepf CY - Basel ER - TY - JOUR A1 - Krause, Gregor A1 - Fruth, Bernhard T1 - Dielectric Properties of Polyolefins Stressed by High Electrical Fields. Fruth, B. ; Krause, G. Y1 - 1987 N1 - Fifth International Symposium on High Voltage Engineering : Proceedings; Braunschweig, Stadthalle, August, 24-28, 1987 / International Symposium on High Voltage Engineering <5, 1987, Braunschweig> ER - TY - JOUR A1 - Krause, Gregor A1 - Göttlich, S. A1 - Möller, K. A1 - Meurer, D. T1 - Space Charge Phenomena in Partially Crystalline Polymers: On-Line Measurement of Charge Carrier Motion under High AC-Field Strength / G. Krause, S. Göttlich, K. Möller, D. Meurer JF - Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics : Trondheim, Norway ... 1989 Y1 - 1989 N1 - International Conference on Conduction and Breakdown in Solid Dielectrics <3, 1989, Trondheim> PB - IEEE CY - Piscataway, N.J. ER - TY - JOUR A1 - Krause, Gregor A1 - Meurer, D. A1 - Klee, D. T1 - Space Charge Formation Related to the Morphology of Polymers JF - ISE 6 : 6th International symposium on electrets : Papers Y1 - 1988 N1 - International Symposium on Electrets <6, 1988, Oxford> PB - IEEE CY - Piscataway, NY ER - TY - JOUR A1 - Krause, Gregor A1 - Meurer, D. A1 - Klee, D. T1 - Space charge formation related to the morphology of polymers JF - IEEE Transaction on Electrical Insulation. Vol. 24 (1989), H. No. 3 Y1 - 1989 N1 - Digital Object Identifier 10.1109/14.30883 SP - 215 EP - 222 ER - TY - JOUR A1 - Krause, Gregor A1 - Möller, K. A1 - Meurer, D. T1 - Dielectric phenomena in semicrystalline polymers JF - IEEE Transaction on Electrical Insulation. Vol. 24 (1989), H. No. 2 Y1 - 1989 N1 - Digital Object Identifier 10.1109/14.90276 SP - 215 EP - 222 ER - TY - JOUR A1 - Krause, Gregor A1 - Neubert, R. A1 - Pietsch, R. T1 - Investigations of Electrical Aging in Polymers under High AC-Field Strength JF - 1990 annual report : October 28 - October 31, 1990 / sponsored by the IEEE Dielectrics and Electrical Insulation Society Y1 - 1990 N1 - Conference on Electrical Insulation and Dielectric Phenomena ; (59, 1990, Pocono Manor, Pa.) PB - IEEE Service Center CY - Piscataway, N.J ER - TY - JOUR A1 - Krause, Gregor A1 - Rodriguez, Jackson A1 - Stopic, Srecko A1 - Friedrich, Bernd T1 - Feasibility assessment of electrocoagulation towards a new sustainable wastewater treatment / Rodriguez, Jackson ; Stopic, Srecko ; Krause Gregor ; Friedrich, Bernd JF - Environmental Science and Pollution Research. 14 (2007), H. 7 Y1 - 2007 SN - 0944-1344 SP - 477 EP - 482 ER - TY - JOUR A1 - Krause, Gregor A1 - Schuppe, W.D. A1 - Saure, M. A1 - Andress, H. T1 - Sensitive Analytical and Physical Methods for Diagnosis of Variations in Polyolefin Plaques and Cable Insulations / W.D. Schuppe, M. Saure, H. Andress, K. Möller, D. Meurer, G. Krause JF - Proceedings of the 32nd session : 28th August - 3rd September. Y1 - 1988 N1 - International Conference on Large Electric Systems, CIGRÉ <32, Paris, 1988> ER - TY - CHAP A1 - Krückel, Kai A1 - Nolden, Florian A1 - Ferrein, Alexander A1 - Scholl, Ingrid T1 - Intuitive visual teleoperation for UGVs using free-look augmented reality displays T2 - 2015 IEEE International Conference on Robotics and Automation (ICRA), Seattle, WA Y1 - 2015 U6 - http://dx.doi.org/10.1109/ICRA.2015.7139809 SP - 4412 EP - 4417 ER - TY - JOUR A1 - Köhler, Klemens T1 - A conflict theory perspective of IT attacks – consequences for IT security education N2 - Cyberspace is "the environment formed by physical and non-physical components to store, modify, and exchange data using computer networks" (NATO CCDCOE). Beyond that, it is an environment where people interact. IT attacks are hostile, non-cooperative interactions that can be described with conflict theory. Applying conflict theory to IT security leads to different objectives for end-user education, requiring different formats like agency-based competence developing games. Y1 - 2020 IS - Preprint ER - TY - JOUR A1 - Köhler, Klemens A1 - Röpke, René A1 - Wolf, Martin T1 - Through a mirror darkly – On the obscurity of teaching goals in game-based learning in IT security JF - ISAGA 2019: Simulation Gaming Through Times and Disciplines N2 - Teachers and instructors use very specific language communicating teaching goals. The most widely used frameworks of common reference are the Bloom’s Taxonomy and the Revised Bloom’s Taxonomy. The latter provides distinction of 209 different teaching goals which are connected to methods. In Competence Developing Games (CDGs - serious games to convey knowledge) and in IT security education, a two- or three level typology exists, reducing possible learning outcomes to awareness, training, and education. This study explores whether this much simpler framework succeeds in achieving the same range of learning outcomes. Method wise a keyword analysis was conducted. The results were threefold: 1. The words used to describe teaching goals in CDGs on IT security education do not reflect the whole range of learning outcomes. 2. The word choice is nevertheless different from common language, indicating an intentional use of language. 3. IT security CDGs use different sets of terms to describe learning outcomes, depending on whether they are awareness, training, or education games. The interpretation of the findings is that the reduction to just three types of CDGs reduces the capacity to communicate and think about learning outcomes and consequently reduces the outcomes that are intentionally achieved. KW - IT security education KW - Competence Developing Games KW - Game-based learning KW - Keyword analysis KW - Bloom’s Taxonomy Y1 - 2021 U6 - http://dx.doi.org/10.1007/978-3-030-72132-9_6 N1 - ISAGA 2019 - International Simulation and Gaming Association Conference. 26-30 August 2019. Warsaw, Poland. Part of the Lecture Notes in Computer Science book series (LNCS, volume 11988) SP - 61 EP - 73 PB - Springer CY - Cham ER - TY - CHAP A1 - Köllensperger, P. A1 - Bragard, Michael A1 - Plum, T. A1 - De Doncker, R. W. T1 - The dual GCT : a new high-power device using optimized GCT technology T2 - Conference record of the 2007 IEEE Industry Applications Conference : 42. IAS annual meeting ; September 23 - 27, 2007, New Orleans, Louisiana, USA Y1 - 2007 SN - 978-1-4244-1260-0 (Online) SN - 978-1-4244-1259-4 (Print) U6 - http://dx.doi.org/10.1109/07IAS.2007.76 SP - 358 EP - 365 PB - IEEE Operations Center CY - Piscataway, NJ ER -