TY - CHAP A1 - Poth, Sebastian A1 - Monzon, Magaly A1 - Tippkötter, Nils A1 - Ulber, Roland T1 - Lignocellulosic biorefinery : process integration of hydrolysis and fermentation T2 - Proceedings / 11th European Workshop on Lignocellulosics and Pulp : August 16 - 19, 2010, Hamburg, Germany Y1 - 2010 SP - 65 EP - 68 PB - vTi CY - Hamburg ER - TY - JOUR A1 - Pourshahidi, Ali Mohammad A1 - Achtsnicht, Stefan A1 - Nambipareechee, Mrinal Murali A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Multiplex detection of magnetic beads using offset field dependent frequency mixing magnetic detection JF - Sensors N2 - Magnetic immunoassays employing Frequency Mixing Magnetic Detection (FMMD) have recently become increasingly popular for quantitative detection of various analytes. Simultaneous analysis of a sample for two or more targets is desirable in order to reduce the sample amount, save consumables, and save time. We show that different types of magnetic beads can be distinguished according to their frequency mixing response to a two-frequency magnetic excitation at different static magnetic offset fields. We recorded the offset field dependent FMMD response of two different particle types at frequencies ƒ₁ + n⋅ƒ₂, n = 1, 2, 3, 4 with ƒ₁ = 30.8 kHz and ƒ₂ = 63 Hz. Their signals were clearly distinguishable by the locations of the extremes and zeros of their responses. Binary mixtures of the two particle types were prepared with different mixing ratios. The mixture samples were analyzed by determining the best linear combination of the two pure constituents that best resembled the measured signals of the mixtures. Using a quadratic programming algorithm, the mixing ratios could be determined with an accuracy of greater than 14%. If each particle type is functionalized with a different antibody, multiplex detection of two different analytes becomes feasible. KW - colorization KW - multiplex detection KW - frequency mixing magnetic detection KW - magnetic nanoparticles Y1 - 2021 U6 - https://doi.org/10.3390/s21175859 SN - 1424-8220 N1 - This article belongs to the Special Issue "Advanced Nanomaterial-Based Sensors for Biomedical Applications" VL - 21 IS - 17 PB - MDPI CY - Basel ER - TY - JOUR A1 - Pourshahidi, Ali Mohammad A1 - Achtsnicht, Stefan A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim ED - Offenhäusser, Andreas T1 - Frequency Mixing Magnetic Detection Setup Employing Permanent Ring Magnets as a Static Offset Field Source JF - Sensors N2 - Frequency mixing magnetic detection (FMMD) has been explored for its applications in fields of magnetic biosensing, multiplex detection of magnetic nanoparticles (MNP) and the determination of core size distribution of MNP samples. Such applications rely on the application of a static offset magnetic field, which is generated traditionally with an electromagnet. Such a setup requires a current source, as well as passive or active cooling strategies, which directly sets a limitation based on the portability aspect that is desired for point of care (POC) monitoring applications. In this work, a measurement head is introduced that involves the utilization of two ring-shaped permanent magnets to generate a static offset magnetic field. A steel cylinder in the ring bores homogenizes the field. By variation of the distance between the ring magnets and of the thickness of the steel cylinder, the magnitude of the magnetic field at the sample position can be adjusted. Furthermore, the measurement setup is compared to the electromagnet offset module based on measured signals and temperature behavior. KW - magnetic sensors KW - biosensors KW - frequency mixing magnetic detection KW - magnetic nanoparticles Y1 - 2022 U6 - https://doi.org/10.3390/s22228776 SN - 1424-8220 VL - 22 IS - 22 PB - MDPI CY - Basel ER - TY - JOUR A1 - Pourshahidi, Ali Mohammad A1 - Engelmann, Ulrich M. A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Resolving ambiguities in core size determination of magnetic nanoparticles from magnetic frequency mixing data JF - Journal of Magnetism and Magnetic Materials N2 - Frequency mixing magnetic detection (FMMD) has been widely utilized as a measurement technique in magnetic immunoassays. It can also be used for the characterization and distinction (also known as “colourization”) of different types of magnetic nanoparticles (MNPs) based on their core sizes. In a previous work, it was shown that the large particles contribute most of the FMMD signal. This leads to ambiguities in core size determination from fitting since the contribution of the small-sized particles is almost undetectable among the strong responses from the large ones. In this work, we report on how this ambiguity can be overcome by modelling the signal intensity using the Langevin model in thermodynamic equilibrium including a lognormal core size distribution fL(dc,d0,σ) fitted to experimentally measured FMMD data of immobilized MNPs. For each given median diameter d0, an ambiguous amount of best-fitting pairs of parameters distribution width σ and number of particles Np with R2 > 0.99 are extracted. By determining the samples’ total iron mass, mFe, with inductively coupled plasma optical emission spectrometry (ICP-OES), we are then able to identify the one specific best-fitting pair (σ, Np) one uniquely. With this additional externally measured parameter, we resolved the ambiguity in core size distribution and determined the parameters (d0, σ, Np) directly from FMMD measurements, allowing precise MNPs sample characterization. Y1 - 2022 U6 - https://doi.org/10.1016/j.jmmm.2022.169969 SN - 0304-8853 VL - 563 IS - In progress, Art. No. 169969 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Preiß, C. A1 - Linder, Peter A1 - Wendt, K. A1 - Krystek, M. A1 - Digel, Ilya A1 - Gossmann, Matthias A1 - Temiz Artmann, Aysegül A1 - Porst, Dariusz A1 - Kayser, Peter A1 - Bassam, Rasha A1 - Artmann, Gerhard T1 - Engineering technology for plant physiology and plant stress research N2 - Plant physiology and plant stress: Plant physiology will be much more important for human mankind because of yield and cultivation limits of crops determined by their resistance to stress. To assess and counteract various stress factors it is necessary to conduct plant research to gain information and results on plant physiology. KW - Pflanzenphysiologie KW - Pflanzenstress KW - Pflanzenscanner KW - plant stress KW - plant scanner Y1 - 2011 ER - TY - JOUR A1 - Pressler, Axel A1 - Esefeld, Katrin A1 - Scherr, Johannes A1 - Ali, Mohammad A1 - Hanssen, Henner A1 - Kotliar, Konstantin A1 - Lanzl, Ines A1 - Halle, Martin A1 - Kaemmerer, Harald A1 - Schmidt-Trucksäss, Arno A1 - Hager, Alfred T1 - Structural alterations of retinal arterioles in adults late after repair of aortic isthmic coarctation JF - The American Journal of Cardiology N2 - Patients after coarctation repair still have an increased risk of cardiovascular or cerebrovascular events. This has been explained by the persisting hypertension and alterations in the peripheral vessels. However, involvement of the central vessels such as the retinal arteries is virtually unknown. A total of 34 patients after coarctation repair (22 men and 12 women; 23 to 58 years old, age range 0 to 32 years at surgical repair) and 34 nonhypertensive controls underwent structural and functional retinal vessel analysis. Using structural analysis, the vessel diameters were measured. Using functional analysis, the endothelium-dependent vessel dilation in response to flicker light stimulation was assessed. In the patients after coarctation repair, the retinal arteriolar diameter was significantly reduced compared to that of the controls (median 182 μm, first to third quartile 171 to 197; vs 197 μm, first to third quartile 193 to 206; p <0.001). These findings were independent of the peripheral blood pressure and age at intervention. No differences were found for venules. The functional analysis findings were not different between the patients and controls (maximum dilation 3.5%, first to third quartile 2.1% to 4.5% vs 3.6%, first to third quartile 2.2% to 4.3%; p = 0.81), indicating preserved autoregulative mechanisms. In conclusion, the retinal artery diameter is reduced in patients after coarctation repair, independent of their current blood pressure level and age at intervention. As a structural marker of chronic vessel damage associated with past, current, or future hypertension, retinal arteriolar narrowing has been linked to stroke incidence. These results indicate an involvement of cerebral microcirculation in aortic coarctation, despite timely repair, and might contribute to explain the increased rate of cerebrovascular events in such patients. Y1 - 2010 U6 - https://doi.org/10.1016/j.amjcard.2009.10.070 SN - 0002-9149 VL - 105 IS - 5 SP - 740 EP - 744 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Pricking, Sebastian A1 - Gebs, Raphael A1 - Fleischhaker, Robert A1 - Kleinbauer, Jochen A1 - Budnicki, Aleksander A1 - Sutter, Dirk A1 - Killi, Alexander A1 - Weiler, Sascha A1 - Mielke, M. A1 - Beaudou, B. A1 - Debord, B. A1 - Gerome, F. A1 - Benabid, F. ED - Dorsch, Friedhelm T1 - Hollow core fiber delivery of sub-ps pulses from a TruMicro 5000 Femto edition thin disk amplifier T2 - High-power laser materials processing: Lasers, beam delivery, diagnostics, and applications IV : 7 Februar 2015, San Francisco, USA. - (SPIE proceedings series ; 9356) Y1 - 2015 SN - 978-162841446-2 U6 - https://doi.org/10.1117/12.2079289 SN - 0277-786X SP - 935602 PB - SPIE, International Society for Optical Engineering ER - TY - CHAP A1 - Priede, Gareth A1 - Ferrein, Alexander T1 - Towards passive walking for the fully-actuated biped robot Nao T2 - Emerging trends in computing, informatics, systems sciences, and engineering. (Lecture notes in electrical engineering : vol. 151) N2 - Many biped robots deploy a form of gait that follows the zero moment point (ZMP) approach, that is, the robot is in a stable position at any point in time. This requires the robot to be fully actuated. While very stable, the draw-backs of this approach are a fairly slow gait and high energy consumption. An alternative approach is the so-called passive-dynamic walking, where the gait makes use of the inertia and dynamic stability of the robot. In this paper we describe our ongoing work of combining the principles of passive-dynamic walking on the fully-actuated biped robot Nao, which is also deployed for robotic soccer applications. We present a simple controller that allows the robot to stably rock sidewards, showing a closed limit-cycle. We discuss first results of superimposing a forward motion on the sidewards motion. Based on this we expect to endow the Nao with a fast, robust, and stable passive-dynamic walk on the fully-actuated Nao in the future. Y1 - 2013 SN - 978-1-4614-3557-0 ; 978-1-4614-3558-7 U6 - https://doi.org/10.1007/978-1-4614-3558-7_18 SP - 225 EP - 236 PB - Springer CY - New York, NY ER - TY - JOUR A1 - Prielmeier, Franz A1 - Hörstermann, D. A1 - Gyngell, M. L. A1 - Merboldt, K.-D. T1 - Localized Proton MRS of Acute and Chronic Gyperglycemia in Rat Brain in vivo / D. Hörstermann, F. Prielmeier , M. L. Gyngell, K.-D. Merboldt, W. Hänicke, J. Frahm JF - Book of Abstracts, SMRM, 11th Annual Meeting Berlin Y1 - 1992 N1 - Society of Magnetic Resonance in Medicine SP - 2740 ER - TY - JOUR A1 - Prielmeier, Franz A1 - Lang, E. W. T1 - Multinuclear Spin-Lattice Relaxation Time Studies of Supercooled Aqueous LiCl-Solutions / E .W. Lang, F. X. Prielmeier JF - Berichte der Bunsen-Gesellschaft für Physikalische Chemie. 92 (1988) Y1 - 1988 SN - 0005-9021 SP - 717 ER - TY - JOUR A1 - Prielmeier, Franz A1 - Lang, E. W. A1 - Lüdemann, H.-D. T1 - Pressure dependence of the self-diffusion in liquid trifluoromethane / F. X. Prielmeier; E. W. Lang; H.-D. Lüdemann JF - Molecular Physics. 52 (1984), H. 5 Y1 - 1984 SN - 0026-8976 SP - 1105 EP - 1113 ER - TY - JOUR A1 - Prielmeier, Franz A1 - Lang, E. W. A1 - Radkowitsch, H. A1 - Lüdemann, H. D. T1 - High Pressure NMR Study of the Molecular Dynamics of Liquid fluoroform and deutero-fluoroform / Lang, E. W. ; Prielmeier, F. X. ; Radkowitsch, H. ; Lüdemann, H. D. JF - Berichte der Bunsen-Gesellschaft für Physikalische Chemie. 91 (1987), H. 10 Y1 - 1987 SN - 0005-9021 SP - 1025 EP - 1033 ER - TY - JOUR A1 - Prielmeier, Franz A1 - Lang, E. W. A1 - Radkowitsch, H. A1 - Lüdemann, H.-D. T1 - High Pressure NMR Study of the Molecular Dynamics of Liquid methyl fluoride and deutero-methyl fluoride / Lang, E. W. ; Prielmeier, F. X. ; Radkowitsch, H. ; Lüdemann, H. D. JF - Berichte der Bunsen-Gesellschaft für Physikalische Chemie. 91 (1987), H. 10 Y1 - 1987 SN - 0005-9021 SP - 1017 EP - 1025 ER - TY - JOUR A1 - Prielmeier, Franz A1 - Lang, E. W. A1 - Speedy, R. J. A1 - Lüdemann, H.-D. T1 - The pressure Dependence of Self Diffusion in Supercooled Light and Heavy Water / F.X. Prielmeier, E .W. Lang, R. J. Speedy, H.-D. Lüdemann JF - Berichte der Bunsen-Gesellschaft für Physikalische Chemie. 92 (1988) Y1 - 1988 SN - 0005-9021 SP - 1111 ER - TY - JOUR A1 - Prielmeier, Franz A1 - Lang, E. W. A1 - Speedy, R. J. A1 - Lüdemann, H.-D. T1 - Diffusion in supercooled water to 300 MPa JF - Physical Review Letters. 59 (1987), H. 10 Y1 - 1987 SN - 0031-9007 SP - 1128 EP - 1131 ER - TY - JOUR A1 - Prielmeier, Franz A1 - Lüdemann, H.-D. T1 - Self diffusion in compressed liquid chloromethane, dichloromethane and trichloromethane / F. X. Prielmeier; H.-D. Lüdemann JF - Molecular Physics. 58 (1986), H. 3 Y1 - 1986 SN - 0026-8976 SP - 593 EP - 604 ER - TY - JOUR A1 - Prielmeier, Franz A1 - Merboldt, K. D. A1 - Hanicke, W. A1 - Frahm, J. T1 - Dynamic high-resolution MR imaging of brain deoxygenation during transient anoxia in the anesthetized rat JF - Journal of cerebral blood flow and metabolism. 13 (1993), H. 5 Y1 - 1993 SN - 0271-678X SP - 889 EP - 894 ER - TY - JOUR A1 - Prielmeier, Franz A1 - Nagatomo, Yasushi A1 - Frahm, Jens T1 - Cerebral blood oxygenation in rat brain during hypoxic hypoxia. Quantitative MRI of effective transverse relaxation rates JF - Magnetic Resonance in Medicine. 31 (1994), H. 6 Y1 - 1994 SN - 0740-3194 SP - 678 EP - 681 ER - TY - JOUR A1 - Prielmeier, Franz A1 - Nagatomo, Yasushi A1 - Wick, Markus A1 - Frahm, Jens T1 - Dynamic monitoring of cerebral metabolites during and after transient global ischemia in rats by quantitative proton NMR spectroscopy in vivo / Yasushi Nagatomo, Markus Wick, Franz Prielmeier, Jens Frahm JF - NMR in Biomedicine. 8 (1995), H. 6 Y1 - 1995 SN - 1099-1492 SP - 265 EP - 270 ER - TY - JOUR A1 - Prielmeier, Franz A1 - Radkowitsch, H. A1 - Lang, E. W. A1 - Lüdemann, H.-D. T1 - Density dependence of the molecular dynamics of fluid CH3F and CF3H studied by NMR / H. Radkowitsch, F. X. Prielmeier, E. W. Lang and H.-D. Lüdemann JF - Physica B+C. 139-140 (1986) Y1 - 1986 SN - 0921-4526 SP - 96 EP - 99 ER -