TY - JOUR A1 - Hüning, Felix A1 - Heuermann, Holger A1 - Wache, Franz-Josef A1 - Jajo, Rami Audisho T1 - A new wireless sensor interface using dual-mode radio JF - Journal of Sensors and Sensor Systems : JSSS N2 - The integration of sensors is one of the major tasks in embedded, control and “internet of things” (IoT) applications. For the integration mainly digital interfaces are used, starting from rather simple pulse-width modulation (PWM) interface to more complex interfaces like CAN (Controller Area Network). Even though these interfaces are tethered by definition, a wireless realization is highly welcome in many applications to reduce cable and connector cost, increase the flexibility and realize new emerging applications like wireless control systems. Currently used wireless solutions like Bluetooth, WirelessHART or IO-Link Wireless use dedicated communication standards and corresponding higher protocol layers to realize the wireless communication. Due to the complexity of the communication and the protocol handling, additional latency and jitter are introduced to the data communication that can meet the requirements for many applications. Even though tunnelling of other bus data like CAN data is generally also possible the latency and jitter prevent the tunnelling from being transparent for the bus system. Therefore a new basic technology based on dual-mode radio is used to realize a wireless communication on the physical layer only, enabling a reliable and real-time data transfer. As this system operates on the physical layer it is independent of any higher layers of the OSI (open systems interconnection) model. Hence it can be used for several different communication systems to replace the tethered physical layer. A prototype is developed and tested for real-time wireless PWM, SENT (single-edge nibble transmission) and CAN data transfer with very low latency and jitter. Y1 - 2018 U6 - https://doi.org/10.5194/jsss-7-507-2018 VL - Volume 7 IS - 2 SP - 507 EP - 515 PB - Copernicus Publ. CY - Göttingen ER - TY - JOUR A1 - Hüning, Felix T1 - Nachrüstmöglichkeiten von Dieselfahrzeugen aus technischer Sicht JF - Zeitschrift für Verkehrsrecht : NZV Y1 - 2019 IS - 1 SP - 27 EP - 32 PB - C.H.Beck ER - TY - JOUR A1 - Heinrichs, Uwe A1 - Utting, Jane F. A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Krombach, Gabriele A. A1 - Hodenius, Michael A. J. A1 - Kozerke, Sebastian A1 - Niendorf, Thoralf T1 - Myocardial T2 mapping free of distortion using susceptibility-weighted fast spin-echo imaging: A feasibility study at 1.5 T and 3.0 T JF - Magnetic Resonance in Medicine N2 - This study demonstrates the feasibility of applying free-breathing, cardiac-gated, susceptibility-weighted fast spin-echo imaging together with black blood preparation and navigator-gated respiratory motion compensation for anatomically accurate T₂ mapping of the heart. First, T₂ maps are presented for oil phantoms without and with respiratory motion emulation (T₂ = (22.1 ± 1.7) ms at 1.5 T and T₂ = (22.65 ± 0.89) ms at 3.0 T). T₂ relaxometry of a ferrofluid revealed relaxivities of R2 = (477.9 ± 17) mM⁻¹s⁻¹ and R2 = (449.6 ± 13) mM⁻¹s⁻¹ for UFLARE and multiecho gradient-echo imaging at 1.5 T. For inferoseptal myocardial regions mean T₂ values of 29.9 ± 6.6 ms (1.5 T) and 22.3 ± 4.8 ms (3.0 T) were estimated. For posterior myocardial areas close to the vena cava T₂-values of 24.0 ± 6.4 ms (1.5 T) and 15.4 ± 1.8 ms (3.0 T) were observed. The merits and limitations of the proposed approach are discussed and its implications for cardiac and vascular T₂-mapping are considered. Y1 - 2009 U6 - https://doi.org/10.1002/mrm.22054 SN - 1522-2594 VL - 62 IS - 3 SP - 822 EP - 828 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Wolf, Martin R. A1 - Altgen, Jannik T1 - IT Service Management in der Region Aachen : White Paper Y1 - 2013 SP - 1 EP - 13 ER - TY - JOUR A1 - Ferrein, Alexander A1 - Meyer, Thomas T1 - A Brief Overview of Artificial Intelligence in South Africa JF - AI Magazine N2 - South Africa in recent years is the establishment of a number of research hubs involved in AI activities ranging from mobile robotics and computational intelligence, to knowledge representation and reasoning, and human language technologies. In this survey we take the reader through a quick tour of the research being conducted at these hubs, and touch on an initiative to maintain and extend the current level of interest in AI research in the country. Y1 - 2012 U6 - https://doi.org/10.1609/aimag.v33i1.2357 SN - 0738-4602 VL - 33 IS - 1 SP - 99 EP - 101 PB - AAAI CY - Menlo Park ER - TY - JOUR A1 - Bragard, Michael A1 - van Hoek, H. A1 - De Doncker, R. W. T1 - A major design step in IETO concept realization that allows overcurrent protection and pushes limits of switching performance JF - IEEE transactions on power electronics N2 - This paper presents the latest prototype of the integrated emitter turn-off thyristor concept, which potentially ranks among thyristor high-power devices like the gate turn-off thyristor and the integrated gate-commutated thyristor (IGCT). Due to modifications of the external driver stage and mechanical press-pack design optimization, this prototype allows for full device characterization. The turn-off capability was increased to 1600 A with an active silicon area of 823mm2 . This leads to a transient peak power of 672.1kW/cm² . Within this paper, measurements and concept assessment are presented and a comparison to state-of-the-art IGCT devices is provided. Y1 - 2012 U6 - https://doi.org/10.1109/TPEL.2012.2189136 SN - 0885-8993 VL - 27 IS - 9 SP - 4163 EP - 4171 PB - IEEE CY - New York ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - de Geyer d'Orth, Thibaut A1 - Dieringer, Matthias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Prothmann, Marcel A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla JF - Journal of Cardiovascular Magnetic Resonance N2 - Background To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. Results ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms. Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). Conclusions The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T. KW - Interval Time Series KW - Image Quality Score KW - Image Quality Assessment KW - Sound Pressure Level KW - Cardiovascular Magnetic Resonance Y1 - 2010 U6 - https://doi.org/10.1186/1532-429X-12-67 SN - 1532-429X VL - 12 IS - 1 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Martin, Conrad A1 - Frauenrath, Tobias A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Niendorf, Thoralf T1 - Development and evaluation of a small and mobile Magneto Alert Sensor (MALSE) to support safety requirements for magnetic resonance imaging JF - European Radiology N2 - Objective The purpose of this study is to (i) design a small and mobile Magnetic field ALert SEnsor (MALSE), (ii) to carefully evaluate its sensors to their consistency of activation/deactivation and sensitivity to magnetic fields, and (iii) to demonstrate the applicability of MALSE in 1.5 T, 3.0 T and 7.0 T MR fringe field environments. Methods MALSE comprises a set of reed sensors, which activate in response to their exposure to a magnetic field. The activation/deactivation of reed sensors was examined by moving them in/out of the fringe field generated by 7TMR. Results The consistency with which individual reed sensors would activate at the same field strength was found to be 100% for the setup used. All of the reed switches investigated required a substantial drop in ambient magnetic field strength before they deactivated. Conclusions MALSE is a simple concept for alerting MRI staff to a ferromagnetic object being brought into fringe magnetic fields which exceeds MALSEs activation magnetic field. MALSE can easily be attached to ferromagnetic objects within the vicinity of a scanner, thus creating a barrier for hazardous situations induced by ferromagnetic parts which should not enter the vicinity of an MR-system to occur. KW - MRI KW - MR safety KW - Magneto alert sensor KW - High field MRI KW - Uktrahigh field MRI Y1 - 2011 U6 - https://doi.org/10.1007/s00330-011-2153-z SN - 1432-1084 VL - 21 SP - 2187 EP - 2192 PB - Springer CY - Berlin, Heidelberg ER - TY - JOUR A1 - Ritz, Thomas A1 - Pisarczyk, Rafael A1 - Sachtleben, Johanna A1 - Leßenich, Nina T1 - Usability Engineering maßgeschneidert : Modellbaukasten zur Entwicklung gebrauchstauglicher mobiler Software JF - Wissenschaft trifft Praxis Y1 - 2014 SN - 2198-8544 (Print) SN - 2198-9362 (Online) N1 - Der Link führt zum vollständigen Heft, der Artikel beginnt auf S.79. VL - 1 IS - 1 SP - 79 EP - 88 PB - Begleitforschung Mittelstand-Digital c/o WIK-Consult GmbH CY - Bad Honnef ER - TY - JOUR A1 - Wallenborn, Ramona A1 - Ritz, Thomas T1 - Mobilität miteinander teilen : städtisches eCarsharing in einer vernetzten Gesellschaft ; [vernetztes Fahren von morgen] JF - Neue Mobilität : das Magazin vom Bundesverband eMobilität Y1 - 2014 SN - 2191-5636 VL - 5 IS - 14 (Herbstausg.) SP - 92 EP - 95 PB - Bundesverband eMobilität BEM CY - Berlin ER - TY - JOUR A1 - Dieringer, Matthias A. A1 - Renz, Wolfgang A1 - Lindel, Tomasz D. A1 - Seifert, Frank A1 - Frauenrath, Tobias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Waiczies, Helmar A1 - Hoffmann, Werner A1 - Rieger, Jan A1 - Pfeiffer, Harald A1 - Ittermann, Bernd A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T JF - Journal of Magnetic Resonance Imaging N2 - Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated. Y1 - 2011 U6 - https://doi.org/10.1002/jmri.22451 SN - 1522-2586 VL - 33 IS - 3 SP - 736 EP - 741 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Schulte-Tigges, Joschua A1 - Förster, Marco A1 - Nikolovski, Gjorgji A1 - Reke, Michael A1 - Ferrein, Alexander A1 - Kaszner, Daniel A1 - Matheis, Dominik A1 - Walter, Thomas T1 - Benchmarking of various LiDAR sensors for use in self-driving vehicles in real-world environments JF - Sensors N2 - Abstract In this paper, we report on our benchmark results of the LiDAR sensors Livox Horizon, Robosense M1, Blickfeld Cube, Blickfeld Cube Range, Velodyne Velarray H800, and Innoviz Pro. The idea was to test the sensors in different typical scenarios that were defined with real-world use cases in mind, in order to find a sensor that meet the requirements of self-driving vehicles. For this, we defined static and dynamic benchmark scenarios. In the static scenarios, both LiDAR and the detection target do not move during the measurement. In dynamic scenarios, the LiDAR sensor was mounted on the vehicle which was driving toward the detection target. We tested all mentioned LiDAR sensors in both scenarios, show the results regarding the detection accuracy of the targets, and discuss their usefulness for deployment in self-driving cars. KW - Lidar KW - Benchmark KW - Self-driving Y1 - 2022 U6 - https://doi.org/10.3390/s22197146 SN - 1424-8220 N1 - This article belongs to the Special Issue "Sensor Fusion for Vehicles Navigation and Robotic Systems" VL - 22 IS - 19 PB - MDPI CY - Basel ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Fuchs, Katharina A1 - Dieringer, Matthias A. A1 - Özerdem, Celal A1 - Patel, Nishan A1 - Renz, Wolfgang A1 - Greiser, Andreas A1 - Elgeti, Thomas A1 - Niendorf, Thoralf T1 - Detailing the use of magnetohydrodynamic effects for synchronization of MRI with the cardiac cycle: A feasibility study JF - Journal of Magnetic Resonance Imaging N2 - Purpose: To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle. Materials and Methods: The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.05–7.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization. Results: The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs. Conclusion: This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364–372. © 2012 Wiley Periodicals, Inc. Y1 - 2012 U6 - https://doi.org/10.1002/jmri.23634 SN - 1522-2586 VL - 36 IS - 2 SP - 364 EP - 372 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Gräßl, Andreas A1 - Renz, Wolfgang A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Winter, Lukas A1 - Özerdem, Celal A1 - Rieger, Jan A1 - Kellmann, Peter A1 - Santoro, Davide A1 - Lindel, Tomasz D. A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Niendorf, Thoralf T1 - Modular 32-channel transceiver coil array for cardiac MRI at 7.0T JF - Magnetic Resonance in Medicine N2 - Purpose To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. Methods The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. Results Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. Conclusion The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T. Y1 - 2013 U6 - https://doi.org/10.1002/mrm.24903 SN - 1522-2594 VL - 72 IS - 1 SP - 276 EP - 290 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Bragard, G. A1 - Bragard, Michael T1 - Ein kostengünstiges, universelles Modellbauinterface JF - Der mathematische und naturwissenschaftliche Unterricht : MNU ; Organ des Deutschen Vereins zur Förderung des Mathematischen und Naturwissenschaftlichen Unterrichts e.V. N2 - Wir stellen einen USB-Baustein vor, der eine kostengünstige und universelle Möglichkeit schafft , im Unterricht den Themenkreis Messen-Steuern-Regeln zu behandeln. Die Funktionalität orientiert sich am CVK-Interface der Firma Fischertechnik. Im Gegensatz zu kommerziellen Lösungen erlaubt unser Aufbau auch den preiswerten Einsatz in Gruppen- oder Einzelarbeit. Abschließend berichten wir über ein Beispiel aus dem Unterrichtseinsatz. Y1 - 2012 SN - 0025-5866 VL - 65 IS - 5 SP - 290 EP - 293 PB - Seeberger CY - Neuss ER - TY - JOUR A1 - Droop, Philipp A1 - Chen, Shaohuang A1 - Radford, Melissa J. A1 - Paulßen, Elisabeth A1 - Gates, Byron D. A1 - Reilly, Raymond M. A1 - Radchenko, Valery A1 - Hoehr, Cornelia T1 - Synthesis of 197m/gHg labelled gold nanoparticles for targeted radionuclide therapy JF - Radiochimica Acta N2 - Meitner-Auger-electron emitters have a promising potential for targeted radionuclide therapy of cancer because of their short range and the high linear energy transfer of Meitner-Auger-electrons (MAE). One promising MAE candidate is 197m/gHg with its half-life of 23.8 h and 64.1 h, respectively, and high MAE yield. Gold nanoparticles (AuNPs) that are labelled with 197m/gHg could be a helpful tool for radiation treatment of glioblastoma multiforme when infused into the surgical cavity after resection to prevent recurrence. To produce such AuNPs, 197m/gHg was embedded into pristine AuNPs. Two different syntheses were tested starting from irradiated gold containing trace amounts of 197m/gHg. When sodium citrate was used as reducing agent, no 197m/gHg labelled AuNPs were formed, but with tannic acid, 197m/gHg labeled AuNPs were produced. The method was optimized by neutralizing the pH (pH = 7) of the Au/197m/gHg solution, which led to labelled AuNPs with a size of 12.3 ± 2.0 nm as measured by transmission electron microscopy. The labelled AuNPs had a concentration of 50 μg (gold)/mL with an activity of 151 ± 93 kBq/mL (197gHg, time corrected to the end of bombardment). KW - 197m/gHg KW - Gold nanoparticle (AuNP) KW - Meitner-Auger-electron (MAE) KW - Targeted radionuclide therapy (TRT) Y1 - 2023 U6 - https://doi.org/10.1515/ract-2023-0144 SN - 2193-3405 VL - 111 IS - 10 SP - 773 EP - 779 PB - De Gruyter CY - Berlin [u.a.] ER - TY - JOUR A1 - Heuermann, Holger T1 - Calibration procedures with series impedances and unknown lines simplify on-wafer measurements JF - IEEE transactions on microwave theory and techniques : MTT ; a publication of the IEEE Microwave Theory and Techniques Society. 47 (1999), H. 1 Y1 - 1999 SN - 0018-9480 SP - 1 EP - 5 ER - TY - JOUR A1 - Heuermann, Holger A1 - Schiek, B. T1 - Error corrected impedance measurements with a network analyzer JF - IEEE transactions on instrumentation and measurement : IM / Institute of Electrical and Electronics Engineers, Instrumentation and Measurement Group. 44 (1995), H. 2 Y1 - 1995 SN - 0018-9456 SP - 295 EP - 299 ER - TY - JOUR A1 - Wolf, Martin R. A1 - Simon, S. A1 - Schlick, Christopher T1 - Qualitative and Quantitative Analysis of Cooperation / Wolf, M. ; Simon, S. ; Schlick, C. JF - Proceedings : May 26 - 29, 1998, Cannes (France) = Actes : 26 - 29 mai 1998 / INRIA, Institut National de Recherche en Informatique et en Automatique, Unité de recherche ... F. Darses ..., eds Y1 - 1998 N1 - COOP ; Institut National de Recherche en Informatique et en Automatique ; Centre ; (Sophia Antipolis) ; International Conference on the Design of Cooperative Systems ; (3 ; 1998.05.26-29 ; Cannes) ; Conference Internationale sur la Conception de Systèmes Coopératifs ; (3 ; 1998.05.26-29 ; Cannes) ; COOP ; (3 ; 1998.05.26-29 ; Cannes) SP - 1 EP - 5 PB - - CY - Cannes ER - TY - JOUR A1 - Ritz, Thomas T1 - Personalized Information Services: Production and Distribution of these Services employing Mass-Customization Y1 - 2002 N1 - International Congress on Mass Media and Communications in the e-society of the 21st Century, Moskau, 17.-19.10.2002 ER -