TY - JOUR A1 - Fredebeul-Krein, Markus A1 - Steingröver, Markus T1 - Wholesale broadband access to IPTV in an NGA environment : how to deal with it from a regulatory perspective? JF - Telecommunications Policy Y1 - 2014 U6 - https://doi.org/doi:10.1016/j.telpol.2013.04.002 SN - 0308-5961 (Print) SN - 1879-3258 (Online) VL - 38 IS - 3 SP - 264 EP - 277 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Augenstein, Eckardt A1 - Herbergs, S. A1 - Kuperjans, Isabel T1 - TOP-Energy : ein Werkzeug zur Optimierung der Gebäudeenergieversorgung JF - KI : Kälte, Luft, Klimatechnik Y1 - 2006 SN - 1865-5432 IS - 5 SP - 198 EP - 201 ER - TY - JOUR A1 - Poghossian, Arshak A1 - Welden, Rene A1 - Buniatyan, Vahe V. A1 - Schöning, Michael Josef T1 - An Array of On-Chip Integrated, Individually Addressable Capacitive Field-Effect Sensors with Control Gate: Design and Modelling JF - Sensors N2 - The on-chip integration of multiple biochemical sensors based on field-effect electrolyte-insulator-semiconductor capacitors (EISCAP) is challenging due to technological difficulties in realization of electrically isolated EISCAPs on the same Si chip. In this work, we present a new simple design for an array of on-chip integrated, individually electrically addressable EISCAPs with an additional control gate (CG-EISCAP). The existence of the CG enables an addressable activation or deactivation of on-chip integrated individual CG-EISCAPs by simple electrical switching the CG of each sensor in various setups, and makes the new design capable for multianalyte detection without cross-talk effects between the sensors in the array. The new designed CG-EISCAP chip was modelled in so-called floating/short-circuited and floating/capacitively-coupled setups, and the corresponding electrical equivalent circuits were developed. In addition, the capacitance-voltage curves of the CG-EISCAP chip in different setups were simulated and compared with that of a single EISCAP sensor. Moreover, the sensitivity of the CG-EISCAP chip to surface potential changes induced by biochemical reactions was simulated and an impact of different parameters, such as gate voltage, insulator thickness and doping concentration in Si, on the sensitivity has been discussed. KW - equivalent circuit KW - multianalyte detection KW - control gate KW - on-chip integrated addressable EISCAP sensors KW - capacitive field-effect sensor Y1 - 2021 U6 - https://doi.org/10.3390/s21186161 SN - 1424-8220 N1 - This article belongs to the Special Issue "Field-Effect Sensors: From pH Sensing to Biosensing" VL - 21 IS - 18 SP - 17 PB - MDPI CY - Basel ER - TY - JOUR A1 - Vahidpour, Farnoosh A1 - Guthman, Eric A1 - Arreola, Julia A1 - Alghazali, Yousef H. M. A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - Assessment of Various Process Parameters for Optimized Sterilization Conditions Using a Multi-Sensing Platform JF - Foods N2 - In this study, an online multi-sensing platform was engineered to simultaneously evaluate various process parameters of food package sterilization using gaseous hydrogen peroxide (H₂O₂). The platform enabled the validation of critical aseptic parameters. In parallel, one series of microbiological count reduction tests was performed using highly resistant spores of B. atrophaeus DSM 675 to act as the reference method for sterility validation. By means of the multi-sensing platform together with microbiological tests, we examined sterilization process parameters to define the most effective conditions with regards to the highest spore kill rate necessary for aseptic packaging. As these parameters are mutually associated, a correlation between different factors was elaborated. The resulting correlation indicated the need for specific conditions regarding the applied H₂O₂ gas temperature, the gas flow and concentration, the relative humidity and the exposure time. Finally, the novel multi-sensing platform together with the mobile electronic readout setup allowed for the online and on-site monitoring of the sterilization process, selecting the best conditions for sterility and, at the same time, reducing the use of the time-consuming and costly microbiological tests that are currently used in the food package industry. KW - spore kill rate KW - sterility KW - aseptic parameters KW - multi-sensing platform KW - gaseous hydrogen peroxide Y1 - 2022 U6 - https://doi.org/10.3390/foods11050660 SN - 2304-8158 N1 - This article belongs to the Special Issue "Sensors and Biosensors Application for Food Industries" VL - 11 IS - 5 PB - MDPI CY - Basel ER - TY - JOUR A1 - Poghossian, Arshak A1 - Karschuck, Tobias A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Field-Effect Capacitors Decorated with Ligand-Stabilized Gold Nanoparticles: Modeling and Experiments JF - Biosensors N2 - Nanoparticles are recognized as highly attractive tunable materials for designing field-effect biosensors with enhanced performance. In this work, we present a theoretical model for electrolyte-insulator-semiconductor capacitors (EISCAP) decorated with ligand-stabilized charged gold nanoparticles. The charged AuNPs are taken into account as additional, nanometer-sized local gates. The capacitance-voltage (C–V) curves and constant-capacitance (ConCap) signals of the AuNP-decorated EISCAPs have been simulated. The impact of the AuNP coverage on the shift of the C–V curves and the ConCap signals was also studied experimentally on Al–p-Si–SiO₂ EISCAPs decorated with positively charged aminooctanethiol-capped AuNPs. In addition, the surface of the EISCAPs, modified with AuNPs, was characterized by scanning electron microscopy for different immobilization times of the nanoparticles. KW - aminooctanethiol KW - nanoparticle coverage KW - capacitive model KW - gold nanoparticles KW - field-effect sensor KW - electrolyte-insulator-semiconductor capacitors Y1 - 2022 U6 - https://doi.org/10.3390/bios12050334 SN - 2079-6374 N1 - This article belongs to the Special Issue "Biosensors in Nanotechnology" VL - 12 IS - 5 PB - MDPI CY - Basel ER - TY - RPRT A1 - Rahier, Michael A1 - Ritz, Thomas A1 - Wallenborn, Ramona T1 - Elektromobilität in einer vernetzten Welt : Potenziale für die IT-Branche bei der Organisation der Mobilität von morgen ; Info-Broschüre N2 - Die Informationsbroschüre „Elektromobilität in einer vernetzten Welt“ richtet sich an IT-Dienstleister. In dieser Broschüre werden mögliche Potenziale im Bereich der Elektromobilität aufgezeigt. Die Mobilität der Zukunft ist eine interdisziplinäre Angelegenheit und kein reines Automotive-Thema mehr. Beispiele wie Mobilitätsmanagement, eCommerce und Individualisierung sind im Mobilitätsbereich für die IT-Branche relevant. Y1 - 2014 PB - eBusiness-Lotse CY - Aachen ER - TY - CHAP A1 - Golland, Alexander ED - Riechert, Anne ED - Wilmer, Thomas T1 - Kommentierung von § 26 Telekommunikation-Telemedien-Datenschutzgesetz T2 - TTDSG Y1 - 2022 SN - 978-3-503-20978-1 N1 - Gedruckte Ausgabe unter 21 QRUG 2 verfügbar. SP - 439 EP - 474 PB - Erich Schmidt CY - Berlin ER - TY - CHAP A1 - Berndt, Heinz A1 - Kalbe, Jochen A1 - Kuropka, Rolf A1 - Meyer-Stork, L. Sebastian A1 - Höcker, Hartwig ED - Körner, Andrea T1 - Progress and limitations of the DNA analysis in fine animal fiber identification T2 - Proceedings of the 2nd International Symposium on Specialty Animal Fibers : Aachen, October 19 - 20, 1989. - (Schriftenreihe des Deutschen Wollforschungsinstituts an der Technischen Hochschule Aachen e. V. ; 106) Y1 - 1990 SP - 259 EP - 265 PB - Dt. Wollforschungsinst. CY - Aachen ER - TY - CHAP A1 - Schwarte, Rudolf A1 - Buxbaum, Bernd A1 - Heinol, Horst-Guenther A1 - Xu, Zhanping A1 - Ringbeck, Thorsten A1 - Zang, Zhigang T1 - Novel 3D-vision systems based on layout optimized PMD-structures T2 - Proceedings / OPTO 98, Internationaler Kongress und Fachausstellung für Optische Sensorik, Messtechnik und Elektronik, 18. - 20. Mai 1998, Kongreßzentrum Erfurt Y1 - 1998 N1 - Internationaler Kongress und Fachausstellung für Optische Sensorik, Messtechnik & Elektronik <3, 1998, Erfurt> ; International Congress and Exhibition on Optoelectronics, Optical Sensors and Measuring Techniques <3, 1998, Erfurt> ; OPTO <3, 1998, Erfurt> SP - 197 EP - 202 PB - ACS Organisations GmbH CY - Wunsdorf ER - TY - CHAP A1 - Kroll-Ludwigs, Kathrin ED - Ermann, Walter, ED - Grunewald, Barbara ED - Maier-Reimer, Georg T1 - Vorbemerkung vor § 1353 T2 - Erman, Bürgerliches Gesetzbuch : Handkommentar mit AGG, EGBGB (Auszug) , ErbbauRG, LPartG, ProdHaftG, VBVG, VersAus-glG und WEG Y1 - 2014 SN - 978-3-50447-102-6 PB - Verlag Dr. Otto Schmidt CY - Köln ER - TY - JOUR A1 - Frohberg, Martin G. A1 - Anik, Sabri T1 - The calculation of component activities of binary metallic melts from their gas solubilities JF - Zeitschrift für Metallkunde Y1 - 1985 SN - 0044-3093 VL - 76 IS - 2 SP - 135 EP - 137 ER - TY - JOUR A1 - Dieringer, Matthias A. A1 - Renz, Wolfgang A1 - Lindel, Tomasz D. A1 - Seifert, Frank A1 - Frauenrath, Tobias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Waiczies, Helmar A1 - Hoffmann, Werner A1 - Rieger, Jan A1 - Pfeiffer, Harald A1 - Ittermann, Bernd A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T JF - Journal of Magnetic Resonance Imaging N2 - Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated. Y1 - 2011 U6 - https://doi.org/10.1002/jmri.22451 SN - 1522-2586 VL - 33 IS - 3 SP - 736 EP - 741 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Fayyazi, Mojgan A1 - Sardar, Paramjotsingh A1 - Thomas, Sumit Infent A1 - Daghigh, Roonak A1 - Jamali, Ali A1 - Esch, Thomas A1 - Kemper, Hans A1 - Langari, Reza A1 - Khayyam, Hamid T1 - Artificial intelligence/machine learning in energy management systems, control, and optimization of hydrogen fuel cell vehicles N2 - Environmental emissions, global warming, and energy-related concerns have accelerated the advancements in conventional vehicles that primarily use internal combustion engines. Among the existing technologies, hydrogen fuel cell electric vehicles and fuel cell hybrid electric vehicles may have minimal contributions to greenhouse gas emissions and thus are the prime choices for environmental concerns. However, energy management in fuel cell electric vehicles and fuel cell hybrid electric vehicles is a major challenge. Appropriate control strategies should be used for effective energy management in these vehicles. On the other hand, there has been significant progress in artificial intelligence, machine learning, and designing data-driven intelligent controllers. These techniques have found much attention within the community, and state-of-the-art energy management technologies have been developed based on them. This manuscript reviews the application of machine learning and intelligent controllers for prediction, control, energy management, and vehicle to everything (V2X) in hydrogen fuel cell vehicles. The effectiveness of data-driven control and optimization systems are investigated to evolve, classify, and compare, and future trends and directions for sustainability are discussed. KW - optimization system KW - intelligent control KW - fuel cell vehicle KW - machine learning KW - artificial intelligence KW - intelligent energy management Y1 - 2023 U6 - https://doi.org/10.3390/su15065249 N1 - This article belongs to the Special Issue "Circular Economy and Artificial Intelligence" VL - 15 IS - 6 SP - 38 PB - MDPI CY - Basel ER - TY - GEN A1 - Tkachenko, Valeriy A1 - von Knobelsdorff-Brenkenhoff, Florian A1 - Kleindienst, Denise A1 - Winter, Lukas A1 - Rieger, Jan A1 - Frauenrath, Tobias A1 - Dieringer, Matthias A. A1 - Santoro, Davide A1 - Niendorf, Thoralf A1 - Schulz-Menger, Jeanette T1 - Cardiovasular MR at 7Tesla: assessment of the right ventricle T2 - 2012 ISMRM Annual Meeting Proceedings N2 - The assessment of the right ventricle (RV) is a challenge in today's cardiology, but of growing clinical impact regarding patient prognosis in different cardiac diseases. The detection and differentiation of small wall motion abnormalities may help to enhance the differentiation of cardiomyopathies including Arrhythmogenic Rightventricular Cardiomyopathy. Cardiovascular magnetic resonance (CMR) at 1.5T is the accepted gold standard for RV quantification. The higher spatial resolution achievable at ultrahigh field strength (UHF) offers the potential to gain new insights into the structure and function of the RV. To approach this goal accurate RV chamber quantification at 7T has to be proven. Consequently this study examines the feasibility of assessment of RV dimensions and function at 7T using improved spatial resolution enabled by the intrinsic sensitivity gain of UHF CMR. For this purpose, a dedicated 16 channel TX/RX RF coil array is used together with 2D CINE fast gradient echo (FGRE) imaging. For comparison RV chamber quantification is conducted at 1.5T using a SSFP based state of the art clinical protocol. Y1 - 2012 SN - 1545-4428 N1 - ISMRM 20th Annual Meeting & Exhibition, 5-11 May 2012, Melbourne, Australia ER - TY - JOUR A1 - Egli, Simon A1 - Ayer, François A1 - Peter, Martina A1 - Eilmann, Britta A1 - Rigling, Andreas T1 - Is forest mushroom productivity driven by tree growth? Results from a thinning experiment JF - Annals of Forest Science N2 - • Most of the edible forest mushrooms are mycorrhizal and depend on carbohydrates produced by the associated trees. Fruiting patterns of these fungi are not yet fully understood since climatic factors alone do not completely explain mushroom occurrence. • The objective of this study was to retrospectively find out if changing tree growth following an increment thinning has influenced the diversity patterns and productivity of associated forest mushrooms in the fungus reserve La Chanéaz, Switzerland. • The results reveal a clear temporal relationship between the thinning, the growth reaction of trees and the reaction of the fungal community, especially for the ectomycorrhizal species. The tree-ring width of the formerly suppressed beech trees and the fruit body number increased after thinning, leading to a significantly positive correlation between fruit body numbers and tree-ring width. • Fruit body production was influenced by previous annual tree growth, the best accordance was found between fruit body production and the tree-ring width two years previously. • The results support the hypothesis that ectomycorrhizal fruit body production must be linked with the growth of the associated host trees. Moreover, the findings indicate the importance of including mycorrhizal fungi as important players when discussing a tree as a carbon source or sink. Y1 - 2010 U6 - https://doi.org/10.1051/forest/2010011 SN - 1286-4560 (Print) SN - 1297-966X (Online) VL - 67 IS - 5 SP - 509 PB - Springer CY - Paris ER - TY - CHAP A1 - Hunker, Jan A1 - Jung, Alexander A1 - Goßmann, Matthias A1 - Linder, Peter A1 - Staat, Manfred ED - Staat, Manfred ED - Erni, Daniel T1 - Development of a tool to analyze the conduction speed in microelectrode array measurements of cardiac tissue T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - The discovery of human induced pluripotent stem cells reprogrammed from somatic cells [1] and their ability to differentiate into cardiomyocytes (hiPSC-CMs) has provided a robust platform for drug screening [2]. Drug screenings are essential in the development of new components, particularly for evaluating the potential of drugs to induce life-threatening pro-arrhythmias. Between 1988 and 2009, 14 drugs have been removed from the market for this reason [3]. The microelectrode array (MEA) technique is a robust tool for drug screening as it detects the field potentials (FPs) for the entire cell culture. Furthermore, the propagation of the field potential can be examined on an electrode basis. To analyze MEA measurements in detail, we have developed an open-source tool. Y1 - 2019 SN - 978-3-940402-22-6 U6 - https://doi.org/10.17185/duepublico/48750 SP - 7 EP - 8 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - PAT A1 - Wahle, Michael A1 - Peter, Roland T1 - Bismaleinimidharze : Offenlegungsschrift / Europäische Patentanmeldung T1 - Bio-maleimide resins Y1 - 1992 PB - Deutsches Patent- und Markenamt / Europäisches Patentamt CY - München / Den Hague ER - TY - JOUR A1 - Egner, Ralf A1 - Heyde, Stefan A1 - Laumann, Jörg A1 - Prokop, Ines T1 - Vorschläge für eine anwenderfreundliche und praxistaugliche Novellierung der allgemeinen Bemessungsregeln und Regeln für den Hochbau (EN 1993 Teil 1-1) JF - Stahlbau Y1 - 2015 U6 - https://doi.org/10.1002/stab.201510321 SN - 1437-1049 VL - 84 IS - 10 SP - 811 EP - 822 PB - Ernst & Sohn CY - Berlin ER - TY - CHAP A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Effect of wind on flight style optimisation in ski jumping T2 - 15th International Symposium on Computer Simulation in Biomechanics ; July 9th-11th 2015, Edinburgh, UK Y1 - 2016 SP - 53 EP - 54 PB - The University of Edinburgh ; Loughborough University CY - Edinburgh ER - TY - CHAP A1 - Finger, Felix T1 - Comparative Performance and Benefit Assessment of VTOL and CTOL UAVs T2 - Deutscher Luft- und Raumfahrtkongress (DLRK) 2016, 13.-15.9.2016 Y1 - 2016 ER -