TY - JOUR A1 - Müller-Veggian, Mattea A1 - Lieder, R. M. A1 - Didelez, J. P. T1 - Crosssections and isomers ratios for ²¹¹,²¹² Po JF - Frühjahrstagung ... des Fachausschusses Kernphysik und Hochenergiephysik der DPG (Sektion A: Kernphysik) / Deutsche Physikalische Gesellschaft (1978) Y1 - 1978 SP - 949 PB - Physik-Verlag CY - Weinheim ER - TY - JOUR A1 - Thust, M. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Naser, S. A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Cross-sensitivity of a capacitive penicillin sensor combined with a diffusion barrier JF - Proceedings : The Hague, The Netherlands, September 12 - 15, 1999 / [ed. by M. Bartek]. - Vol 1. Y1 - 1999 SN - 90-76699-02-X N1 - Eurosensors <13, 1999, 's-Gravenhage> ; Eurosensors <13, 1999, The Hague> ; European Conference on Solid-State Transducers <13, 1999, The Hague> SP - 573 EP - 576 CY - The Hague, The Netherlands ER - TY - JOUR A1 - Poghossian, Arshak A1 - Thust, M. A1 - Schöning, Michael Josef A1 - Müller-Veggian, Mattea A1 - Kordos, P. A1 - Lüth, H. T1 - Cross-sensitivity of a capacitive penicillin sensor combined with a diffusion barrier JF - Sensors and Actuators B. 68 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 260 EP - 265 ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Lieder, R. M. A1 - Didelez, J. P. T1 - Cross sections and isomer ratios for ²¹¹,²¹² Po JF - Annual report 1977 / Institut für Kernphysik Kernforschungsanlage Jülich Y1 - 1978 N1 - Spezielle Berichte der Kernforschungsanlage Jülich ; 15 SP - 49 EP - 50 PB - Verlag des Forschungszentrums Jülich CY - Jülich ER - TY - JOUR A1 - Rübbelke, Dirk A1 - Vögele, Stefan A1 - Grajewski, Matthias A1 - Zobel, Luzy T1 - Cross border adjustment mechanism: Initial data for the assessment of hydrogen-based steel production JF - Data in Brief N2 - Ambitious climate targets affect the competitiveness of industries in the international market. To prevent such industries from moving to other countries in the wake of increased climate protection efforts, cost adjustments may become necessary. Their design requires knowledge of country-specific production costs. Here, we present country-specific cost figures for different production routes of steel, paying particular attention to transportation costs. The data can be used in floor price models aiming to assess the competitiveness of different steel production routes in different countries (Rübbelke, 2022). KW - Energy-intensive industry KW - Steel industry KW - Competitiveness KW - Floor prices KW - Cross border adjustment mechanism Y1 - 2023 U6 - https://doi.org/10.1016/j.dib.2023.108907 SN - 2352-3409 VL - 47 IS - Article 108907 SP - 1 EP - 5 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Kämper, Klaus-Peter A1 - Schmitt, W. A1 - Güntherodt, G. A1 - Gambino, R. J. T1 - CrO2—A New Half-Metallic Ferromagnet? Kämper, K.-P.; Schmitt, W.; Güntherodt, G.; Gambino, R. J., Ruf, R. JF - Physical Review Letters. 59 (1987), H. 24 Y1 - 1987 SN - 1079-7114 SP - 2788 EP - 2791 ER - TY - JOUR A1 - Schopen, Oliver A1 - Shah, Neel A1 - Esch, Thomas A1 - Shabani, Bahman T1 - Critical quantitative evaluation of integrated health management methods for fuel cell applications JF - International Journal of Hydrogen Energy N2 - Online fault diagnostics is a crucial consideration for fuel cell systems, particularly in mobile applications, to limit downtime and degradation, and to increase lifetime. Guided by a critical literature review, in this paper an overview of Health management systems classified in a scheme is presented, introducing commonly utilised methods to diagnose FCs in various applications. In this novel scheme, various Health management system methods are summarised and structured to provide an overview of existing systems including their associated tools. These systems are classified into four categories mainly focused on model-based and non-model-based systems. The individual methods are critically discussed when used individually or combined aimed at further understanding their functionality and suitability in different applications. Additionally, a tool is introduced to evaluate methods from each category based on the scheme presented. This tool applies the technique of matrix evaluation utilising several key parameters to identify the most appropriate methods for a given application. Based on this evaluation, the most suitable methods for each specific application are combined to build an integrated Health management system. KW - Fuel cell KW - Health management system KW - Online diagnostic KW - Fault detection KW - Non-model-based Evaluation Y1 - 2024 U6 - https://doi.org/10.1016/j.ijhydene.2024.05.156 SN - 0360-3199 VL - 70 SP - 370 EP - 388 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Tillmann, K. A1 - Förster, Arnold T1 - Critical dimensions for the formation of interfacial misfit dislocations of In0.6Ga0.4As islands on GaAs(001) JF - Thin Solid Films. 368 (2000), H. 1 Y1 - 2000 SN - 0040-6090 SP - 93 EP - 104 ER - TY - JOUR A1 - Enning, Manfred A1 - Stützle, Thorsten A1 - Viereck, Uwe A1 - Stribersky, Anton T1 - Creepage control for use in wheelslide protection systems / Stützle, Thorsten ; Viereck, Uwe ; Stribersky, Anton ; Rulka, Wolfgang ; Enning, Manfred ; Abel, Dirk JF - Control in transportation systems : proceedings of the 11th IFAC symposium on control in transportation systems (CTS 2006), August 29-31, 2006, Delft, the Netherlands / International Federation of Automatic Control Y1 - 2006 SN - 0742-5953 ER - TY - JOUR A1 - Chen, Bixia A1 - Schoemberg, Tobias A1 - Kraff, Oliver A1 - Dammann, Philipp A1 - Bitz, Andreas A1 - Schlamann, Marc A1 - Quick, Harald H. A1 - Ladd, Mark E. A1 - Sure, Ulrich A1 - Wrede, Karsten H. T1 - Cranial fixation plates in cerebral magnetic resonance imaging: a 3 and 7 Tesla in vivo image quality study JF - Magnetic Resonance Materials in Physics, Biology and Medicine N2 - Objective This study assesses and quantifies impairment of postoperative magnetic resonance imaging (MRI) at 7 Tesla (T) after implantation of titanium cranial fixation plates (CFPs) for neurosurgical bone flap fixation. Materials and methods The study group comprised five patients who were intra-individually examined with 3 and 7 T MRI preoperatively and postoperatively (within 72 h/3 months) after implantation of CFPs. Acquired sequences included T₁-weighted magnetization-prepared rapid-acquisition gradient-echo (MPRAGE), T₂-weighted turbo-spin-echo (TSE) imaging, and susceptibility-weighted imaging (SWI). Two experienced neurosurgeons and a neuroradiologist rated image quality and the presence of artifacts in consensus reading. Results Minor artifacts occurred around the CFPs in MPRAGE and T2 TSE at both field strengths, with no significant differences between 3 and 7 T. In SWI, artifacts were accentuated in the early postoperative scans at both field strengths due to intracranial air and hemorrhagic remnants. After resorption, the brain tissue directly adjacent to skull bone could still be assessed. Image quality after 3 months was equal to the preoperative examinations at 3 and 7 T. Conclusion Image quality after CFP implantation was not significantly impaired in 7 T MRI, and artifacts were comparable to those in 3 T MRI. Y1 - 2016 U6 - https://doi.org/10.1007/s10334-016-0548-1 SN - 1352-8661 VL - 29 IS - 3 SP - 389 EP - 398 PB - Springer CY - Berlin ER - TY - JOUR A1 - Gaigall, Daniel A1 - Gerstenberg, Julian T1 - Cramér-von-Mises tests for the distribution of the excess over a confidence level JF - Journal of Nonparametric Statistics N2 - The Cramér-von-Mises distance is applied to the distribution of the excess over a confidence level. Asymptotics of related statistics are investigated, and it is seen that the obtained limit distributions differ from the classical ones. For that reason, quantiles of the new limit distributions are given and new bootstrap techniques for approximation purposes are introduced and justified. The results motivate new one-sample goodness-of-fit tests for the distribution of the excess over a confidence level and a new confidence interval for the related fitting error. Simulation studies investigate size and power of the tests as well as coverage probabilities of the confidence interval in the finite sample case. A practice-oriented application of the Cramér-von-Mises tests is the determination of an appropriate confidence level for the fitting approach. The adoption of the idea to the well-known problem of threshold detection in the context of peaks over threshold modelling is sketched and illustrated by data examples. KW - Cramér-von-Mises test KW - conditional excess distribution KW - confidence interval KW - goodness-of-fit test Y1 - 2023 U6 - https://doi.org/10.1080/10485252.2023.2173958 SN - 1048-5252 (Print) SN - 1029-0311 (Online) PB - Taylor & Francis ER - TY - JOUR A1 - Call, Guido T1 - Couponing JF - Das Wirtschaftsstudium : wisu ; Zeitschrift für Ausbildung, Examen, Berufseinstieg und Weiterbildung. 32 (2003), H. 11 Y1 - 2003 SN - 0340-3084 SP - 1372 EP - 1377 ER - TY - JOUR A1 - Schroth, P. A1 - Schöning, Michael Josef A1 - Schütz, S. A1 - Malkoc, Ü. A1 - Steffen, A. A1 - Marso, M. A1 - Hummel, Hans E. A1 - Kordos, P. A1 - Lüth, H. T1 - Coupling of insect antennae to field-effect transistors for biochemical sensing JF - Electrochimica Acta. 44 (1999), H. 21-22 Y1 - 1999 SN - 0013-4686 SP - 3821 EP - 3826 ER - TY - JOUR A1 - Molinnus, Denise A1 - Poghossian, Arshak A1 - Keusgen, Michael A1 - Katz, Evgeny A1 - Schöning, Michael Josef T1 - Coupling of Biomolecular Logic Gates with Electronic Transducers: From Single Enzyme Logic Gates to Sense/Act/Treat Chips JF - Electroanalysis N2 - The integration of biomolecular logic principles with electronic transducers allows designing novel digital biosensors with direct electrical output, logically triggered drug-release, and closed-loop sense/act/treat systems. This opens new opportunities for advanced personalized medicine in the context of theranostics. In the present work, we will discuss selected examples of recent developments in the field of interfacing enzyme logic gates with electrodes and semiconductor field-effect devices. Special attention is given to an enzyme OR/Reset logic gate based on a capacitive field-effect electrolyte-insulator-semiconductor sensor modified with a multi-enzyme membrane. Further examples are a digital adrenaline biosensor based on an AND logic gate with binary YES/NO output and an integrated closed-loop sense/act/treat system comprising an amperometric glucose sensor, a hydrogel actuator, and an insulin (drug) sensor. Y1 - 2017 U6 - https://doi.org/10.1002/elan.201700208 SN - 1521-4109 VL - 29 IS - 8 SP - 1840 EP - 1849 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Krämer, Melina A1 - Pita, Marcos A1 - Zhou, Jian A1 - Ornatska, Maryna A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Katz, Evgeny T1 - Coupling of Biocomputing Systems with Electronic Chips: Electronic Interface for Transduction of Biochemical Information JF - Journal of Physical Chemistry C: Nanomaterials and Interfaces. 113 (2009), H. 6 Y1 - 2009 SN - 1932-7455 SP - 2573 EP - 2579 PB - American Cemical Society CY - Washington, DC ER - TY - JOUR A1 - Martin, S. A. A1 - Berg, G. P. A. A1 - Hacker, U. A1 - Hardt, Arno A1 - Köhler, M. A1 - Meißburger, J. A1 - Osterfeld, F. A1 - Prasuhn, D. A1 - Riepe, G. A1 - Rogge, M. A1 - Schult, O. W. B. A1 - Speth, J. A1 - Turek, P. A1 - Gaul, G. A1 - Hagedoorn, H. A1 - Heide, J. A. van der A1 - Hinterberger, F. A1 - Huber, M. A1 - Jahn, R. A1 - Mayer-Kuckuk, T. A1 - Poth, H. A1 - Paetz gen. Schieck, H. T1 - COSY - a cooler synchrotron and storage ring JF - IEEE transactions on nuclear science. Vol. 32, iss. 5 Y1 - 1985 SN - 1558-1578 (E-Journal); 0018-9499 (Print) SP - 2694 EP - 2696 ER - TY - JOUR A1 - Wolisz, Henryk A1 - Schütz, Thomas A1 - Blanke, Tobias A1 - Hagenkamp, Markus A1 - Kohrn, Markus A1 - Wesseling, Mark A1 - Müller, Dirk T1 - Cost optimal sizing of smart buildings' energy system components considering changing end-consumer electricity markets JF - Energy Y1 - 2017 U6 - https://doi.org/10.1016/j.energy.2017.06.025 VL - 137 SP - 715 EP - 728 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Laack, Walter van A1 - Casser, H. R. T1 - Cortisonbedingte Ablederung der Hüftkopfkappe / Laack, W. van ; Casser, H. R. JF - Neuere Ergebnisse in der Osteologie : Skelettwachstum, Endoprothetik, Glukokortikoide ; [15. - 18. Februar 1989 in Göttingen] / H.-G. Willert ; F. H. W. Heuck (Hrsg.) Y1 - 1989 SN - 3-540-51175-X N1 - Osteologia ; 4 SP - 566 EP - 568 PB - Springer CY - Berlin ER - TY - JOUR A1 - Jung, Alexander A1 - Staat, Manfred A1 - Müller, Wolfram T1 - Corrigendum to “Flight style optimization in ski jumping on normal, large, and ski flying hills” [J. Biomech 47 (2014) 716–722] JF - Journals of Biomechanics Y1 - 2018 U6 - https://doi.org/10.1016/j.jbiomech.2018.02.001 SN - 0021-9290 N1 - refers to Journal of Biomechanics Vol 47, Issue 3, Pages 716-722: https://doi.org/10.1016/j.jbiomech.2013.11.021 SP - 313 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Sponagel, Stefan A1 - Baroud, G. A1 - Falk, R. A1 - Crookshank, M. T1 - Corrigendum to “Experimental and theoretical investigation of directional permeability of human vertebral cancellous bone for cement infiltration”. Baroud, G.; Falk, R.; Crookshank, M.; Sponagel, S.; Steffen, T. JF - Journal of Biomechanics. 37 (2004), H. 2 Y1 - 2004 SN - 0021-9290 SP - 1802 ER -