TY - CHAP A1 - Gebhardt, Andreas A1 - Ritz, Thomas A1 - Siekmann, Kirsten A1 - Wallenborn, Ramona ED - Demmer, Axel T1 - Additive manufacturing businesses in the process chain of individualized mass products T2 - DDMC 2014 : Proceedings of the Fraunhofer Direct Digital Manufacturing Conference Y1 - 2014 SN - 978-3-8396-9128-1 (E-Book) PB - Fraunhofer CY - Stuttgart ER - TY - BOOK A1 - Galley, Birgit A1 - Minoggio, Ingo A1 - Schuba, Marko A1 - Bischoff, Barbara A1 - Höfken, Hans-Wilhelm T1 - Unternehmenseigene Ermittlungen : Recht - Kriminalistik - IT Y1 - 2016 SN - 978-3-503-16531-5 PB - Erich Schmidt Verlag CY - Berlin ER - TY - CHAP A1 - Galdi, Chiara A1 - Hartung, Frank A1 - Dugelay, Jean-Luc T1 - Socrates: A database of realistic data for source camera recognition on smartphones T2 - Proceedings of the 8th International Conference on Pattern Recognition Applications and Methods - Volume 1: ICPRAM Y1 - 2019 SN - 978-989-758-351-3 U6 - https://doi.org/10.5220/0007403706480655 SP - 648 EP - 655 ER - TY - CHAP A1 - Galdi, Chiara A1 - Hartung, Frank A1 - Dugelay, Jean-Luc T1 - Videos versus still images: Asymmetric sensor pattern noise comparison on mobile phones T2 - Electronic Imaging N2 - Nowadays, the most employed devices for recoding videos or capturing images are undoubtedly the smartphones. Our work investigates the application of source camera identification on mobile phones. We present a dataset entirely collected by mobile phones. The dataset contains both still images and videos collected by 67 different smartphones. Part of the images consists in photos of uniform backgrounds, especially collected for the computation of the RSPN. Identifying the source camera given a video is particularly challenging due to the strong video compression. The experiments reported in this paper, show the large variation in performance when testing an highly accurate technique on still images and videos. KW - Image Forensics KW - Mobile Phones KW - Image Database Y1 - 2017 U6 - https://doi.org/10.2352/ISSN.2470-1173.2017.7.MWSF-331 SN - 2470-1173 N1 - IS&T International Symposium on Electronic Imaging 2017 Media Watermarking, Security, and Forensics 2017 SP - 100 EP - 103 PB - Society for Imaging Science and Technology CY - Springfield, Virginia ER - TY - CHAP A1 - Fuchs, Britta A1 - Ritz, Thomas A1 - Strauch, Jakob ED - Obaidat, Mohammad S. T1 - Usability of mobile applications : dissemination of usability engineering in small and medium enterprises T2 - Proceedings of the International Conference on Data Communication Networking, e-Business and Optical Communication Systems : Rome, Italy, 24 - 27 July, 2012 ; [integrated in the ICETE (International Conference on e-Business and Telecommunications)] Y1 - 2012 SN - 978-989-8565-23-5 N1 - Nebentitel: DCNET; ICE-B; OPTICS SP - 272 EP - 277 PB - SciTePress CY - [Lissabon] ER - TY - JOUR A1 - Fuchs, Britta A1 - Ritz, Thomas T1 - Absatzkanäle kaum verknüpft JF - IT-Mittelstand : IT-Business im Mittelstand Y1 - 2011 VL - 2011 IS - 9 SP - 16 PB - Medienhaus-Verlag CY - Bergisch-Gladbach ER - TY - CHAP A1 - Fuchs, Britta A1 - Ritz, Thomas T1 - Usability for Blended Shopping - Solving Major Flaws by Applying Usability Engineering and Proven Integration Technologies T2 - Proceedings of the 11th International Conference on e-Business, ICE-B 2014, Vienna, Austria Y1 - 2014 SN - 978-989-758-043-7 U6 - https://doi.org/10.5220/0005113502160223 SP - 216 EP - 223 ER - TY - GEN A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Winter, Lukas A1 - Gräßl, Andreas A1 - Santoro, Davide A1 - Özerdem, Celal A1 - Renz, Wolfgang A1 - Greiser, Andreas A1 - Niendorf, Thoralf T1 - Lessons learned from cardiac MRI at 7.0 T: LV function assessment at 3.0 T using local multi-channel transceiver coil arrays T2 - 2012 ISMRM Annual Meeting Proceedings N2 - Cardiac MR (CMR) is of proven clinical value but also an area of vigorous ongoing research since image quality is not always exclusively defined by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Recent developments of CMR at 7.0 T have been driven by pioneering explorations into novel multichannel transmit and receive coil array technology to tackle the challenges B1+-field inhomogeneities, to offset specific-absorption rate (SAR) constraints and to reduce banding artifacts in SSFP imaging. For this study, recognition of the benefits and performance of local surface Tx/Rx-array structures recently established at 7.0 T inspired migration to 3.0 T, where RF inhomogeneities and SAR limitations encountered in routine clinical CMR, though somewhat reduced versus the 7.0 T situation, remain significant. For all these reasons, this study was designed to build and examine the feasibility of a local four channel Tx/Rx cardiac coil array for anatomical and functional cardiac imaging at 3.0 T. For comparison, a homebuilt 4 channel Rx cardiac coil array exhibiting the same geometry as the Tx/Rx coil and a Rx surface coil array were used. Y1 - 2012 SN - 1545-4428 N1 - ISMRM 20th Annual Meeting & Exhibition, 5-11 May 2012, Melbourne, Australia ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Niendorf, Thoralf A1 - Kob, Malte T1 - Acoustic method for synchronization of Magnetic Resonance Imaging (MRI) JF - Acta Acustica N2 - Magnetic Resonance Imaging (MRI) of moving organs requires synchronization with physiological motion or flow, which dictate the viable window for data acquisition. To meet this challenge, this study proposes an acoustic gating device (ACG) that employs acquisition and processing of acoustic signals for synchronization while providing MRI compatibility, immunity to interferences with electro-magnetic and acoustic fields and suitability for MRI at high magnetic field strengths. The applicability and robustness of the acoustic gating approach is examined in a pilot study, where it substitutes conventional ECG-gating for cardiovascular MR. The merits and limitations of the ACG approach are discussed. Implications for MR imaging in the presence of physiological motion are considered including synchronization with other structure- or motion borne sounds. Y1 - 2008 U6 - https://doi.org/10.3813/AAA.918017 SN - 1861-9959 VL - 94 IS - 1 SP - 148 EP - 155 PB - Hirzel CY - Stuttgart ER - TY - PAT A1 - Frauenrath, Tobias A1 - Niendorf, Thoralf T1 - MRT-Vorrichtung und Verfahren zum Betreiben einer MRT-Vorrichtung T1 - Magnetic resonance tomography (MRT) apparatus and method of operating a magnetic resonance (MR) apparatus T1 - Appareil de tomographie par résonance magnétique et procédé de fonctionnement d'un appareil à résonance magnétique N2 - A magnetic resonance tomography (MRT) apparatus (1) for the examination of a body (14) comprises parameter acquisition devices (13) for the acquisition of cardiovascular parameters of the body (14) and a control device (15) in communication with the parameter acquisition devices (13) for synchronizing the imaging, wherein the control device (15) is adapted to analyse the data of at least two parameter acquisition devices (13) and to output a control signal based on the analysis. Y1 - 2012 ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Hezel, Fabian A1 - Renz, Wolfgang A1 - de Geyer d'Orth, Thibaut A1 - Dieringer, Matthias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Prothmann, Marcel A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla JF - Journal of Cardiovascular Magnetic Resonance N2 - Background To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. Results ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms. Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). Conclusions The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T. KW - Interval Time Series KW - Image Quality Score KW - Image Quality Assessment KW - Sound Pressure Level KW - Cardiovascular Magnetic Resonance Y1 - 2010 U6 - https://doi.org/10.1186/1532-429X-12-67 SN - 1532-429X VL - 12 IS - 1 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Frauenrath, Tobias A1 - Fuchs, Katharina A1 - Dieringer, Matthias A. A1 - Özerdem, Celal A1 - Patel, Nishan A1 - Renz, Wolfgang A1 - Greiser, Andreas A1 - Elgeti, Thomas A1 - Niendorf, Thoralf T1 - Detailing the use of magnetohydrodynamic effects for synchronization of MRI with the cardiac cycle: A feasibility study JF - Journal of Magnetic Resonance Imaging N2 - Purpose: To investigate the feasibility of using magnetohydrodynamic (MHD) effects for synchronization of magnetic resonance imaging (MRI) with the cardiac cycle. Materials and Methods: The MHD effect was scrutinized using a pulsatile flow phantom at B0 = 7.0 T. MHD effects were examined in vivo in healthy volunteers (n = 10) for B0 ranging from 0.05–7.0 T. Noncontrast-enhanced MR angiography (MRA) of the carotids was performed using a gated steady-state free-precession (SSFP) imaging technique in conjunction with electrocardiogram (ECG) and MHD synchronization. Results: The MHD potential correlates with flow velocities derived from phase contrast MRI. MHD voltages depend on the orientation between B0 and the flow of a conductive fluid. An increase in the interelectrode spacing along the flow increases the MHD potential. In vivo measurement of the MHD effect provides peak voltages of 1.5 mV for surface areas close to the common carotid artery at B0 = 7.0 T. Synchronization of MRI with the cardiac cycle using MHD triggering is feasible. MHD triggered MRA of the carotids at 3.0 T showed an overall image quality and richness of anatomic detail, which is comparable to ECG-triggered MRAs. Conclusion: This feasibility study demonstrates the use of MHD effects for synchronization of MR acquisitions with the cardiac cycle. J. Magn. Reson. Imaging 2012;36:364–372. © 2012 Wiley Periodicals, Inc. Y1 - 2012 U6 - https://doi.org/10.1002/jmri.23634 SN - 1522-2586 VL - 36 IS - 2 SP - 364 EP - 372 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Franke, Helmut A1 - Streckert, Joachim A1 - Bitz, Andreas A1 - Goeke, Johannes A1 - Hansen, Volkert A1 - Ringelstein, E. Bernd A1 - Nattkämper, Heiner A1 - Galle, Hans-Joachim A1 - Stögbauer, Florian T1 - Effects of Universal Mobile Telecommunications System (UMTS) electromagnetic fields on the blood-brain barrier in vitro JF - Radiation Research Y1 - 2005 U6 - https://doi.org/10.1667/RR3424.1 SN - 1938-5404 VL - 164 IS - 3 SP - 258 EP - 269 ER - TY - JOUR A1 - Foltz, Christian A1 - Schneider, Nicole A1 - Wolf, Martin R. A1 - Kausch, Bernhard A1 - Schlick, Christopher A1 - Luczak, Holger ED - Nagl, Manfred T1 - Usability engineering JF - Collaborative and distributed chemical engineering : from understanding to substantial design process support; results of the IMPROVE Project. - (Lecture notes in computer science ; 4970) Y1 - 2008 SN - 978-3-540-70552-9 U6 - https://doi.org/10.1007/978-3-540-70552-9_21 SP - 527 EP - 554 PB - Springer CY - Berlin ER - TY - CHAP A1 - Finger, Felix A1 - Khalsa, R. A1 - Kreyer, Jörg A1 - Mayntz, Joscha A1 - Braun, Carsten A1 - Dahmann, Peter A1 - Esch, Thomas A1 - Kemper, Hans A1 - Schmitz, O. A1 - Bragard, Michael T1 - An approach to propulsion system modelling for the conceptual design of hybrid-electric general aviation aircraft T2 - Deutscher Luft- und Raumfahrtkongress 2019, 30.9.-2.10.2019, Darmstadt N2 - In this paper, an approach to propulsion system modelling for hybrid-electric general aviation aircraft is presented. Because the focus is on general aviation aircraft, only combinations of electric motors and reciprocating combustion engines are explored. Gas turbine hybrids will not be considered. The level of the component's models is appropriate for the conceptual design stage. They are simple and adaptable, so that a wide range of designs with morphologically different propulsive system architectures can be quickly compared. Modelling strategies for both mass and efficiency of each part of the propulsion system (engine, motor, battery and propeller) will be presented. Y1 - 2019 ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Orzada, Stephan A1 - Flöser, Martina A1 - Rietsch, Stefan H. G. A1 - Schmidt, Simon A1 - Stelter, Jonathan K. A1 - Wittrich, Marco A1 - Quick, Harald H. A1 - Bitz, Andreas A1 - Ladd, Mark E. T1 - Performance and safety assessment of an integrated transmit array for body imaging at 7 T under consideration of specificabsorption rate, tissue temperature, and thermal dose JF - NMR in Biomedicine N2 - In this study, the performance of an integrated body-imaging array for 7 T with 32 radiofrequency (RF) channels under consideration of local specific absorption rate (SAR), tissue temperature, and thermal dose limits was evaluated and the imaging performance was compared with a clinical 3 T body coil. Thirty-two transmit elements were placed in three rings between the bore liner and RF shield of the gradient coil. Slice-selective RF pulse optimizations for B1 shimming and spokes were performed for differently oriented slices in the body under consideration of realistic constraints for power and local SAR. To improve the B1+ homogeneity, safety assessments based on temperature and thermal dose were performed to possibly allow for higher input power for the pulse optimization than permissible with SAR limits. The results showed that using two spokes, the 7 T array outperformed the 3 T birdcage in all the considered regions of interest. However, a significantly higher SAR or lower duty cycle at 7 T is necessary in some cases to achieve similar B1+ homogeneity as at 3 T. The homogeneity in up to 50 cm-long coronal slices can particularly benefit from the high RF shim performance provided by the 32 RF channels. The thermal dose approach increases the allowable input power and the corresponding local SAR, in one example up to 100 W/kg, without limiting the exposure time necessary for an MR examination. In conclusion, the integrated antenna array at 7 T enables a clinical workflow for body imaging and comparable imaging performance to a conventional 3 T clinical body coil. KW - body imaging at 7 T MRI KW - thermal dose KW - tissue temperature KW - transmit antenna arrays Y1 - 2022 U6 - https://doi.org/10.1002/nbm.4656 SN - 0952-3480 (Print) SN - 1099-1492 (Online) VL - 35 IS - 5 SP - 1 EP - 17 PB - Wiley ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Orzada, Stephan A1 - Flöser, Martina A1 - Rietsch, Stefan H. G. A1 - Quick, Harald H. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - Performance analysis of integrated RF microstrip transmit antenna arrays with high channel count for body imaging at 7 T JF - NMR in Biomedicine N2 - The aim of the current study was to investigate the performance of integrated RF transmit arrays with high channel count consisting of meander microstrip antennas for body imaging at 7 T and to optimize the position and number of transmit ele- ments. RF simulations using multiring antenna arrays placed behind the bore liner were performed for realistic exposure conditions for body imaging. Simulations were performed for arrays with as few as eight elements and for arrays with high channel counts of up to 48 elements. The B1+ field was evaluated regarding the degrees of freedom for RF shimming in the abdomen. Worst-case specific absorption rate (SARwc ), SAR overestimation in the matrix compression, the number of virtual obser- vation points (VOPs) and SAR efficiency were evaluated. Constrained RF shimming was performed in differently oriented regions of interest in the body, and the devia- tion from a target B1+ field was evaluated. Results show that integrated multiring arrays are able to generate homogeneous B1+ field distributions for large FOVs, espe- cially for coronal/sagittal slices, and thus enable body imaging at 7 T with a clinical workflow; however, a low duty cycle or a high SAR is required to achieve homoge- neous B1+ distributions and to exploit the full potential. In conclusion, integrated arrays allow for high element counts that have high degrees of freedom for the pulse optimization but also produce high SARwc , which reduces the SAR accuracy in the VOP compression for low-SAR protocols, leading to a potential reduction in array performance. Smaller SAR overestimations can increase SAR accuracy, but lead to a high number of VOPs, which increases the computational cost for VOP evaluation and makes online SAR monitoring or pulse optimization challenging. Arrays with interleaved rings showed the best results in the study. KW - body imaging at UHF MRI KW - integrated transmit coil arrays KW - VOP compression Y1 - 2021 U6 - https://doi.org/10.1002/nbm.4515 SN - 0952-3480 (ISSN) SN - 1099-1492 (eISSN) VL - 34 IS - 7 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Clemens, Markus A1 - Bitz, Andreas T1 - Safety of subjects during radiofrequency exposure in ultra-high-field magnetic resonance imaging JF - IEEE Letters on Electromagnetic Compatibility Practice and Applications N2 - Magnetic resonance imaging (MRI) is one of the most important medical imaging techniques. Since the introduction of MRI in the mid-1980s, there has been a continuous trend toward higher static magnetic fields to obtain i.a. a higher signal-to-noise ratio. The step toward ultra-high-field (UHF) MRI at 7 Tesla and higher, however, creates several challenges regarding the homogeneity of the spin excitation RF transmit field and the RF exposure of the subject. In UHF MRI systems, the wavelength of the RF field is in the range of the diameter of the human body, which can result in inhomogeneous spin excitation and local SAR hotspots. To optimize the homogeneity in a region of interest, UHF MRI systems use parallel transmit systems with multiple transmit antennas and time-dependent modulation of the RF signal in the individual transmit channels. Furthermore, SAR increases with increasing field strength, while the SAR limits remain unchanged. Two different approaches to generate the RF transmit field in UHF systems using antenna arrays close and remote to the body are investigated in this letter. Achievable imaging performance is evaluated compared to typical clinical RF transmit systems at lower field strength. The evaluation has been performed under consideration of RF exposure based on local SAR and tissue temperature. Furthermore, results for thermal dose as an alternative RF exposure metric are presented. Y1 - 2020 SN - 2637-6423 U6 - https://doi.org/10.1109/LEMCPA.2020.3029747 VL - 2 IS - 3 SP - 1 EP - 8 PB - IEEE CY - New York, NY ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - SAR Simulations & Safety JF - NeuroImage Y1 - 2017 U6 - https://doi.org/10.1016/j.neuroimage.2017.03.035 SN - 1053-8119 IS - Epub ahead of print PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus temperature limits JF - Medical Physics Y1 - 2017 U6 - https://doi.org/10.1002/mp.12034 N1 - This article is corrected by: Errata: Erratum: “RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus tissue temperature limits” [Med. Phys. 44(1), 143–157 (2017)] Volume 44, Issue 2, 772 VL - 44 IS - 1 SP - 143 EP - 157 ER -