TY - GEN A1 - Waiczies, Helmar A1 - Kühne, André A1 - Winter, Lukas A1 - Frauenrath, Tobias A1 - Hoffmann, Werner A1 - Ittermann, Bernd A1 - Waiczies, Sonia A1 - Niendorf, Thoralf T1 - Towards theranostics of rheumatoid arthritis: 1H/19F imaging of non-steroidal anti-inflammatory drugs in hand and wrist at 7 Tesla T2 - 2013 ISMRM Annual Meeting Proceedings N2 - We have developed a double-tuned ¹H/¹⁹F birdcage resonator dedicated for hand and wrist imaging at 7 T to locally image non-steroidal anti-inflammatory drugs (NSAID) such as 2-{[3-(Trifluoromethyl) phenyl]amino}benzoic acid. The preliminary in vivo images acquired by the double-tuned ¹H/¹⁹F birdcage resonator demonstrate the feasibility for ¹H/¹⁹F hand- and wrist-imaging at 7 T. While the diagnostic quality of the coil needs to be assessed in patients with inflammatory rheumatoid disease, first ¹⁹F images of the NSAID are encouraging, and point towards the prospect of applying ¹⁹F-MRI to visualize and quantify the concentration of therapeutically-active compound at the sites of inflammation. Y1 - 2013 SN - 1545-4428 N1 - ISMRM 21st Annual Meeting & Exhibition, 20-26 April 2013, Salt Lake City, Utah, USA ER - TY - CHAP A1 - Nötzold, K. A1 - Uphues, A. A1 - Wegener, R. A1 - Fink, K. A1 - Bragard, Michael A1 - Griessel, R. A1 - Soter, S. T1 - Inverter based test setup for LVRT verification of a full-scale 2 MW wind power converter T2 - 15th European Conference on Power Electronics and Applications (EPE), 2013 : 2 - 6 Sept. 2013, Lille, France / [EPE Association; PELS, IEEE Power Electronics Society] Y1 - 2013 SN - 978-1-4799-0115-9 (Online-Ausg.) U6 - https://doi.org/10.1109/EPE.2013.6634752 SP - 1037 EP - 1042 PB - IEEE CY - Piscataway, NJ ER - TY - CHAP A1 - Damm, Sebastian A1 - Rahier, Michael A1 - Ritz, Thomas A1 - Schäfer, Thomas ED - Davoli, Renzo T1 - Architecture for platform- and hardware-independent mesh networks : how to unify the channels T2 - ICSNC 2013 : The Eighth International Conference on Systems and Networks Communications ; October 27, 2013 to October 31, 2013, Venice Italy N2 - This paper will prove that mesh networks among different platforms and hardware channels can help to channel valuable information even if public telecommunication infrastructure is not available due to arbitrary reasons. Therefore, results of a simulation for mesh networks on mass events will be provided, followed by the developed architecture and an outlook on future research. The developed architecture is currently being implemented and field tested on mass events. Y1 - 2013 SN - 978-1-61208-305-6 N1 - IARIA Conference SP - 131 EP - 134 PB - Curran Associates CY - Red Hook, NY ER - TY - CHAP A1 - Wolf, Martin R. A1 - Wiese, Ute T1 - A comparative transformation model for process changes using serious games T2 - 2013 IEEE 2nd International Conference on Serious Games and Applications for Health (SeGAH): proceedings of a meeting held 2-3 May 2013, Algarve, Portugal Y1 - 2013 SN - 978-1-4673-6164-4 U6 - https://doi.org/10.1109/SeGAH.2013.6665307 SP - 64 EP - 70 PB - Institute of Electrical and Electronics Engineers (IEEE) CY - Piscataway, NJ ER - TY - JOUR A1 - Gräßl, Andreas A1 - Renz, Wolfgang A1 - Hezel, Fabian A1 - Dieringer, Matthias A. A1 - Winter, Lukas A1 - Özerdem, Celal A1 - Rieger, Jan A1 - Kellmann, Peter A1 - Santoro, Davide A1 - Lindel, Tomasz Dawid A1 - Frauenrath, Tobias A1 - Pfeiffer, Harald A1 - Niendorf, Thoralf T1 - Modular 32-channel transceiver coil array for cardiac MRI at 7.0T JF - Magnetic Resonance in Medicine N2 - Purpose To design and evaluate a modular transceiver coil array with 32 independent channels for cardiac MRI at 7.0T. Methods The modular coil array comprises eight independent building blocks, each containing four transceiver loop elements. Numerical simulations were used for B1+ field homogenization and radiofrequency (RF) safety validation. RF characteristics were examined in a phantom study. The array's suitability for accelerated high spatial resolution two-dimensional (2D) FLASH CINE imaging of the heart was examined in a volunteer study. Results Transmission field adjustments and RF characteristics were found to be suitable for the volunteer study. The signal-to-noise intrinsic to 7.0T together with the coil performance afforded a spatial resolution of 1.1 × 1.1 × 2.5 mm3 for 2D CINE FLASH MRI, which is by a factor of 6 superior to standardized CINE protocols used in clinical practice at 1.5T. The 32-channel transceiver array supports one-dimensional acceleration factors of up to R = 4 without impairing image quality significantly. Conclusion The modular 32-channel transceiver cardiac array supports accelerated and high spatial resolution cardiac MRI. The array is compatible with multichannel transmission and provides a technological basis for future clinical assessment of parallel transmission techniques at 7.0T. Y1 - 2013 U6 - https://doi.org/10.1002/mrm.24903 SN - 1522-2594 VL - 72 IS - 1 SP - 276 EP - 290 PB - Wiley-Liss CY - New York ER - TY - CHAP A1 - Schütz, P. A1 - Breuer, M. A1 - Höfken, Hans-Wilhelm A1 - Schuba, Marko T1 - Malware proof on mobile phone exhibits based on GSM/GPRS traces T2 - The Second International Conference on Cyber Security, Cyber Peacefare and Digital Forensic (CyberSec 2013) : 04.03. - 06.03.2013, Kuala Lumpur, Malaysia Y1 - 2013 SN - 978-0-9853483-7-3 SP - 89 EP - 96 PB - The Society of Digital Information and Wireless Communication ER - TY - CHAP A1 - Stöbe, Rolf A1 - Höfken, Hans-Wilhelm A1 - Schuba, Marko A1 - Breuer, Michael T1 - Artificial ageing of mobile devices using a simulated GSM/GPRS network T2 - Eighth International Conference on Availability, Reliability and Security (ARES) : 2-6 Sept. 2013, Regensburg Y1 - 2013 SP - 493 EP - 497 PB - IEEE ER -