TY - JOUR A1 - Belavy, Daniel L. A1 - Albracht, Kirsten A1 - Brüggemann, Gert-Peter A1 - Vergroesen, Pieter-Paul A. A1 - Dieen, Jaap H. van T1 - Can exercise positively influence the intervertebral disc? JF - Sports Medicine N2 - To better understand what kinds of sports and exercise could be beneficial for the intervertebral disc (IVD), we performed a review to synthesise the literature on IVD adaptation with loading and exercise. The state of the literature did not permit a systematic review; therefore, we performed a narrative review. The majority of the available data come from cell or whole-disc loading models and animal exercise models. However, some studies have examined the impact of specific sports on IVD degeneration in humans and acute exercise on disc size. Based on the data available in the literature, loading types that are likely beneficial to the IVD are dynamic, axial, at slow to moderate movement speeds, and of a magnitude experienced in walking and jogging. Static loading, torsional loading, flexion with compression, rapid loading, high-impact loading and explosive tasks are likely detrimental for the IVD. Reduced physical activity and disuse appear to be detrimental for the IVD. We also consider the impact of genetics and the likelihood of a ‘critical period’ for the effect of exercise in IVD development. The current review summarises the literature to increase awareness amongst exercise, rehabilitation and ergonomic professionals regarding IVD health and provides recommendations on future directions in research. KW - Intradiscal Pressure KW - Annulus Fibrosus KW - Disc Degeneration KW - Nucleus Pulposus KW - Intervertebral Disc Y1 - 2016 U6 - https://doi.org/10.1007/s40279-015-0444-2 SN - 1179-2035 VL - 46 IS - 4 SP - 473 EP - 485 PB - Springer CY - Berlin ER - TY - JOUR A1 - Yang, Peng-Fei A1 - Kriechbaumer, Andreas A1 - Albracht, Kirsten A1 - Sanno, Maximilian A1 - Ganse, Bergita A1 - Koy, Timmo A1 - Shang, Peng A1 - Brüggemann, Gert-Peter A1 - Müller, Lars Peter A1 - Rittweger, Jörn T1 - A novel optical approach for assessing in vivo bone segment deformation and its application in muscle-bone relationship studies in humans JF - Journal of Orthopaedic Translation Y1 - 2014 U6 - https://doi.org/10.1016/j.jot.2014.07.078 SN - 2214-0328 SN - 2214-031X VL - 2 IS - 4 SP - 238 EP - 238 PB - Elsevier CY - Singapore ER - TY - JOUR A1 - Ribitsch, D. A1 - Heumann, S. A1 - Trotscha, E. A1 - Herrero Acero, E. A1 - Greimel, K. A1 - Leber, R. A1 - Birner-Gruenberger, R. A1 - Deller, S. A1 - Eiteljoerg, I. A1 - Remler, P. A1 - Weber, Th. A1 - Siegert, Petra A1 - Maurer, Karl-Heinz A1 - Donelli, I. A1 - Freddi, G. A1 - Schwab, H. A1 - Guebitz, G. M. T1 - Hydrolysis of polyethyleneterephthalate by p-nitrobenzylesterase from Bacillus subtilis JF - Biotechnology progress Y1 - 2011 SN - 1520-6033 (E-Journal); 8756-7938 (Print) VL - Vol. 27 IS - Iss. 4 SP - 951 EP - 960 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Wilson, Thomas L. A1 - Blome, Hans-Joachim A1 - LaFave, Norman T1 - Astrophysical Cosmology Using a Lunar Ligo JF - Engineering, construction, and operations in space V : proceedings of the Fifth International Conference on Space '96, Albuquerque, New Mexico, June 1-6, 1996 / sponsored by Aerospace Division of the American Society of Civil Engineers ... [et al.]; edite Y1 - 1996 SN - 0-7844-0177-2 SP - 861 EP - 863 PB - The Society CY - New York ER - TY - JOUR A1 - Baumann, Marcus A1 - Lara, R.J. A1 - Hubberten, D.N. A1 - Thomas, D. N. T1 - Dissolved organic matter studies in enclosed systems: Application of hydophobic fractionation for the assessment of organic nitrogen dynamics / Lara, R.J. ; Hubberten, U. ; Thomas, D.N. ; Baumann, M.E.M. ; Kattner, G. JF - Journal of Marine Systems. 13 (1997), H. 1-4 Y1 - 1997 SN - 0924-7963 SP - 155 EP - 161 ER - TY - JOUR A1 - Baumann, Marcus A1 - Thomas, D. N. A1 - Gleitz, M. T1 - Efficiency of carbon assimilation and photoacclimation in a small unicellular Chaetoceros species from the Weddel Sea (Antarctica): Influence of temperature and irridiance / Thomas, D. ; Baumann, M.E.M. ; Gleitz, M. JF - Journal of Experimental Marine Biology and Ecology. 157 (1992), H. 2 Y1 - 1992 SN - 0022-0981 SP - 195 EP - 209 ER - TY - JOUR A1 - Hagemann, Hans-Jürgen A1 - Bachmann, Peter K. A1 - Lade, H. A1 - Leers, D. T1 - Diamond chemical vapor deposition: gas compositions and film properties / Bachmann, P.K.; Hagemann, H.-J.; Lade, H; Leers, D.; Picht, F.; Wiechert, D.U.; Wilson, H. JF - Diamond, SiC and nitride wide bandgap semiconductors : symposium held April 4 - 8, 1994, San Francisco, California, U.S.A. / ed.: Calvin H. Carter, Jr. ... Y1 - 1994 SN - 1-55899-239-1 N1 - Materials Research Society symposium proceedings ; 339 SP - 267 EP - 277 CY - Pittsburgh, Penn. ER - TY - JOUR A1 - Leimena, W. A1 - Artmann, Gerhard A1 - Dachwald, Bernd A1 - Temiz Artmann, Aysegül A1 - Gossmann, Matthias A1 - Digel, Ilya T1 - Feasibility of an in-situ microbial decontamination of an ice-melting probe JF - Eurasian Chemico-Technological Journal N2 - Autonomous robotic systems for penetrating thick ice shells with simultaneous collecting of scientific data are very promising devices in both terrestrial (glacier, climate research) and extra-terrestrial applications. Technical challenges in development of such systems are numerous and include 3D-navigation, an appropriate energy source, motion control, etc. Not less important is the problem of forward contamination of the pristine glacial environments with microorganisms and biomolecules from the surface of the probe. This study was devoted to establishing a laboratory model for microbial contamination of a newly constructed ice-melting probe called IceMole and to analyse the viability and amount of the contaminating microorganisms as a function of distance. The used bacterial strains were Bacillus subtilis (ATCC 6051) and Escherichia coli (ATCC 11775). The main objective was development of an efficient and reliable in-situ decontamination method of the melting probe. Therefore, several chemical substances were tested in respect of their efficacy to eliminate bacteria on the surface of the melting probe at low temperature (0 - 5 °C) and at continuous dilution by melted water. Our study has shown that at least 99.9% decontamination of the IceMole can be successfully achieved by the injection of 30% (v/v) hydrogen peroxide and 3% (v/v) sodium hypochlorite into the drilling site. We were able to reproduce this result in both time-dependent and depth-dependent experiments. The sufficient amount of 30% (v/v) H₂O₂ or 3% (v/v) NaClO has been found to be approximately 18 L per cm² of the probe’s surface. Y1 - 2010 SN - 1562-3920 U6 - https://doi.org/10.18321/ectj37 VL - 12 IS - 2 SP - 145 EP - 150 PB - Institute of Combustion Problems CY - Almaty ER - TY - JOUR A1 - Jansen, S. V. A1 - Behbahani, Mehdi A1 - Laumen, M. A1 - Kaufmann, T. A1 - Hormes, M. A1 - Behr, M. A1 - Schmitz-Rode, T. A1 - Steinseifer, U. T1 - Investigation of Steady Flow Through a Realistic Model of the Thoracic Human Aorta Using 3D Stereo PIV and CFD-Simulation JF - ASAIO Journal Y1 - 2010 U6 - https://doi.org/10.1097/01.mat.0000369377.65122.a3 N1 - American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 VL - 56 IS - 2 SP - 98 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - JOUR A1 - Behbahani, Mehdi A1 - Nam, J. A1 - Waluga, C. A1 - Behr, M. A1 - Pasquali, M. A1 - Mottaghy, K. T1 - Modeling and Numerical Analysis of Platelet Activation, Adhesion and Aggregation in Artificial Organs Y1 - 2010 U6 - https://doi.org/10.1097/01.mat.0000369377.65122.a3 N1 - Posterpresentation American Society of Artificial Organs (ASAIO), Baltimore, USA, May 27-29, 2010 VL - 56 IS - 2 SP - 85 PB - Lippincott Williams & Wilkins CY - Philadelphia ER - TY - JOUR A1 - Ferrein, Alexander A1 - Siebel, Nils T. A1 - Steinbauer, Gerald T1 - Hybrid control for autonomous systems — Integrating learning, deliberation and reactive control JF - Robotics and Autonomous Systems Y1 - 2010 U6 - https://doi.org/10.1016/j.robot.2010.06.003 SN - 0921-8890 VL - 58 IS - 9 SP - 1037 EP - 1038 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Niemüller, Tim A1 - Ferrein, Alexander A1 - Lakemeyer, Gerhard T1 - A Lua-based behavior engine for controlling the humanoid robot Nao JF - RoboCup 2009: Robot Soccer World Cup XIII Y1 - 2010 U6 - https://doi.org/10.1007/978-3-642-11876-0_21 N1 - Part of the book series: Lecture Notes in Computer Science ((LNAI,volume 5949)) N1 - 13th RoboCup International Symposium, Graz, Austria, June/July, 2009 SP - 240 EP - 251 PB - Springer CY - Heidelberg ER - TY - JOUR A1 - Orzada, Stephan A1 - Solbach, Klaus A1 - Gratz, Marcel A1 - Brunheim, Sascha A1 - Fiedler, Thomas M. A1 - Johst, Sören A1 - Bitz, Andreas A1 - Shooshtary, Samaneh A1 - Abuelhaija, Ashraf A1 - Voelker, Maximilian N. A1 - Rietsch, Stefan H. G. A1 - Kraff, Oliver A1 - Maderwald, Stefan A1 - Flöser, Martina A1 - Oehmingen, Mark A1 - Quick, Harald H. A1 - Ladd, Mark E. T1 - A 32-channel parallel transmit system add-on for 7T MRI JF - Plos one Y1 - 2019 U6 - https://doi.org/10.1371/journal.pone.0222452 ER - TY - JOUR A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Johst, Sören A1 - Gratz, Marcel A1 - Völker, Maximilian N. A1 - Kraff, Oliver A1 - Abuelhaija, Ashraf A1 - Fiedler, Thomas M. A1 - Solbach, Klaus A1 - Quick, Harald H. A1 - Ladd, Mark E. T1 - Analysis of an integrated 8-Channel Tx/Rx body array for use as a body coil in 7-Tesla MRI JF - Frontiers in Physics Y1 - 2017 U6 - https://doi.org/10.3389/fphy.2017.00017 SN - 2296-424X N1 - Article number 17 VL - 5 IS - Jun ER - TY - JOUR A1 - Scholl, Ingrid A1 - Palm, Christoph A1 - Lehmann, Thomas Martin A1 - Spitzer, Klaus T1 - Quantitative Farbmessung in laryngoskopischen Bildern. Palm, C; Scholl, I; Lehmann, TM; Spitzer, K. JF - Bildverarbeitung für die Medizin 1998. Hrsg.: Thomas Lehmann ... Y1 - 1998 SN - 3-540-63885-7 SP - 412 EP - 416 PB - Springer CY - Berlin ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus temperature limits JF - Medical Physics Y1 - 2017 U6 - https://doi.org/10.1002/mp.12034 N1 - This article is corrected by: Errata: Erratum: “RF safety assessment of a bilateral four-channel transmit/receive 7 Tesla breast coil: SAR versus tissue temperature limits” [Med. Phys. 44(1), 143–157 (2017)] Volume 44, Issue 2, 772 VL - 44 IS - 1 SP - 143 EP - 157 ER - TY - JOUR A1 - Dieringer, Matthias A. A1 - Renz, Wolfgang A1 - Lindel, Tomasz Dawid A1 - Seifert, Frank A1 - Frauenrath, Tobias A1 - von Knobelsdorf-Brenkenhoff, Florian A1 - Waiczies, Helmar A1 - Hoffmann, Werner A1 - Rieger, Jan A1 - Pfeiffer, Harald A1 - Ittermann, Bernd A1 - Schulz-Menger, Jeanette A1 - Niendorf, Thoralf T1 - Design and application of a four-channel transmit/receive surface coil for functional cardiac imaging at 7T JF - Journal of Magnetic Resonance Imaging N2 - Purpose To design and evaluate a four-channel cardiac transceiver coil array for functional cardiac imaging at 7T. Materials and Methods A four-element cardiac transceiver surface coil array was developed with two rectangular loops mounted on an anterior former and two rectangular loops on a posterior former. specific absorption rate (SAR) simulations were performed and a Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-1 calibration method was applied prior to obtain 2D FLASH CINE (mSENSE, R = 2) images from nine healthy volunteers with a spatial resolution of up to 1 × 1 × 2.5 mm3. Results Tuning and matching was found to be better than 10 dB for all subjects. The decoupling (S21) was measured to be >18 dB between neighboring loops, >20 dB for opposite loops, and >30 dB for other loop combinations. SAR values were well within the limits provided by the IEC. Imaging provided clinically acceptable signal homogeneity with an excellent blood-myocardium contrast applying the Burn:x-wiley:10531807:media:JMRI22451:tex2gif-stack-2 calibration approach. Conclusion A four-channel cardiac transceiver coil array for 7T was built, allowing for cardiac imaging with clinically acceptable signal homogeneity and an excellent blood-myocardium contrast. Minor anatomic structures, such as pericardium, mitral, and tricuspid valves and their apparatus, as well as trabeculae, were accurately delineated. Y1 - 2011 U6 - https://doi.org/10.1002/jmri.22451 SN - 1522-2586 VL - 33 IS - 3 SP - 736 EP - 741 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Fiedler, Thomas M. A1 - Ladd, Mark E. A1 - Clemens, Markus A1 - Bitz, Andreas T1 - Safety of subjects during radiofrequency exposure in ultra-high-field magnetic resonance imaging JF - IEEE Letters on Electromagnetic Compatibility Practice and Applications N2 - Magnetic resonance imaging (MRI) is one of the most important medical imaging techniques. Since the introduction of MRI in the mid-1980s, there has been a continuous trend toward higher static magnetic fields to obtain i.a. a higher signal-to-noise ratio. The step toward ultra-high-field (UHF) MRI at 7 Tesla and higher, however, creates several challenges regarding the homogeneity of the spin excitation RF transmit field and the RF exposure of the subject. In UHF MRI systems, the wavelength of the RF field is in the range of the diameter of the human body, which can result in inhomogeneous spin excitation and local SAR hotspots. To optimize the homogeneity in a region of interest, UHF MRI systems use parallel transmit systems with multiple transmit antennas and time-dependent modulation of the RF signal in the individual transmit channels. Furthermore, SAR increases with increasing field strength, while the SAR limits remain unchanged. Two different approaches to generate the RF transmit field in UHF systems using antenna arrays close and remote to the body are investigated in this letter. Achievable imaging performance is evaluated compared to typical clinical RF transmit systems at lower field strength. The evaluation has been performed under consideration of RF exposure based on local SAR and tissue temperature. Furthermore, results for thermal dose as an alternative RF exposure metric are presented. Y1 - 2020 SN - 2637-6423 U6 - https://doi.org/10.1109/LEMCPA.2020.3029747 VL - 2 IS - 3 SP - 1 EP - 8 PB - IEEE CY - New York, NY ER - TY - JOUR A1 - Blome, Hans-Joachim A1 - Mashhoon, Bahram T1 - Quasi-normal oscillations of a Schwarzschild black hole JF - Physics Letters A. 100 (1984), H. 5 Y1 - 1984 SN - 0375-9601 SP - 231 EP - 234 ER - TY - JOUR A1 - Baroud, Gamal A1 - Wu, J.Z. A1 - Bohner, M A1 - Sponagel, Stefan A1 - Steffen, T. T1 - How to determine the permeability for cement infiltration into osteoporotic cancellous bone JF - Medical Engineering & Physics. 25 (2003), H. 4 N2 - Cement augmentation is an emerging surgical procedure in which bone cement is used to infiltrate and reinforce osteoporotic vertebrae. Although this infiltration procedure has been widely applied, it is performed empirically and little is known about the flow characteristics of cement during the injection process. We present a theoretical and experimental approach to investigate the intertrabecular bone permeability during the infiltration procedure. The cement permeability was considered to be dependent on time, bone porosity, and cement viscosity in our analysis. In order to determine the time-dependent permeability, ten cancellous bone cores were harvested from osteoporotic vertebrae, infiltrated with acrylic cement at a constant flow rate, and the pressure drop across the cores during the infiltration was measured. The viscosity dependence of the permeability was determined based on published experimental data. The theoretical model for the permeability as a function of bone porosity and time was then fit to the testing data. Our findings suggest that the intertrabecular bone permeability depends strongly on time. For instance, the initial permeability (60.89 mm4/N.s) reduced to approximately 63% of its original value within 18 seconds. This study is the first to analyze cement flow through osteoporotic bone. The theoretical and experimental models provided in this paper are generic. Thus, they can be used to systematically study and optimize the infiltration process for clinical practice. KW - Osteoporose KW - Permeabilität KW - Viskose Strömung KW - Viskosität KW - Vertebroplastie KW - Cement infiltration KW - Vertebroplasty KW - Osteoporosis KW - Permeability KW - Experiment KW - Analysis KW - Viscous flow Y1 - 2003 SN - 1350-4533 SP - 283 EP - 288 ER -