TY - JOUR A1 - Reißel, Martin A1 - Lustfeld, Hans A1 - Hirschfeld, Julian A. A1 - Steffen, Bernhard T1 - Uniqueness of magnetotomography for fuel cells and fuel cell stacks / Lustfeld, H. ; Hirschfeld, J. ; Reißel, M ; Steffen, B. JF - Journal of Physics A: Mathematical and Theoretical. 42 (2009), H. 495205 Y1 - 2009 SN - 0022-3689 SP - 9 S. ER - TY - JOUR A1 - Stulpe, Werner T1 - Unitary Operator JF - Compendium of Quantum Physics : concepts, experiments, history and philosophy / Daniel Greenberger ... ed. Y1 - 2009 SN - 978-3-540-70622-9 SP - 807 EP - 809 PB - Springer CY - Berlin ER - TY - JOUR A1 - Bialonski, Stephan A1 - Wendler, Martin A1 - Lehnertz, Klaus T1 - Unraveling spurious properties of interaction networks with tailored random networks JF - Plos one N2 - We investigate interaction networks that we derive from multivariate time series with methods frequently employed in diverse scientific fields such as biology, quantitative finance, physics, earth and climate sciences, and the neurosciences. Mimicking experimental situations, we generate time series with finite length and varying frequency content but from independent stochastic processes. Using the correlation coefficient and the maximum cross-correlation, we estimate interdependencies between these time series. With clustering coefficient and average shortest path length, we observe unweighted interaction networks, derived via thresholding the values of interdependence, to possess non-trivial topologies as compared to Erdös-Rényi networks, which would indicate small-world characteristics. These topologies reflect the mostly unavoidable finiteness of the data, which limits the reliability of typically used estimators of signal interdependence. We propose random networks that are tailored to the way interaction networks are derived from empirical data. Through an exemplary investigation of multichannel electroencephalographic recordings of epileptic seizures – known for their complex spatial and temporal dynamics – we show that such random networks help to distinguish network properties of interdependence structures related to seizure dynamics from those spuriously induced by the applied methods of analysis. Y1 - 2011 U6 - https://doi.org/10.1371/journal.pone.0022826 VL - 6 IS - 8 PB - Plos CY - San Francisco ER - TY - JOUR A1 - Müller-Veggian, Mattea A1 - Jannsens, R. A1 - Masri, Y. El. A1 - Michel, C. T1 - Untersuchung der Hochspinzustände in ¹⁷⁸,¹⁸⁰ Os JF - Frühjahrstagung ... des Fachausschusses Kernphysik und Hochenergiephysik der DPG (Sektion A: Kernphysik) / Deutsche Physikalische Gesellschaft. 11 (1976) Y1 - 1976 N1 - Verhandlungen der Deutschen Physikalischen Gesellschaft ; 1976=6.R.11,8 SP - 950 ER - TY - THES A1 - Pham, Phu Tinh T1 - Upper bound limit and shakedown analysis of elastic-plastic bounded linearly kinematic hardening structures Y1 - 2011 N1 - Aachen, Techn. Hochsch., Diss., 2011 PB - RWTH Aachen University CY - Aachen ER - TY - JOUR A1 - Tran, Thanh Ngoc A1 - Kreißig, R. A1 - Vu, Duc Khoi A1 - Staat, Manfred T1 - Upper bound limit and shakedown analysis of shells using the exact Ilyushin yield surface JF - Computer & Structures. 86 (2008) Y1 - 2008 SN - 0045-7949 SP - 1683 EP - 1695 ER - TY - JOUR A1 - Seifarth, Volker A1 - Schehl, D. A1 - Linder, Peter A1 - Gossmann, Matthias A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Porst, Dariusz A1 - Preiß, C. A1 - Kayser, Peter A1 - Pack, O. A1 - Temiz Artmann, Aysegül T1 - Ureplace: development of a bioreactor for in vitro culturing of cell seeded tubular vessels on collagen scaffolds N2 - The demand of replacements for inoperable organs exceeds the amount of available organ transplants. Therefore, tissue engineering developed as a multidisciplinary field of research for autologous in-vitro organs. Such three dimensional tissue constructs request the application of a bioreactor. The UREPLACE bioreactor is used to grow cells on tubular collagen scaffolds OPTIMAIX Sponge 1 with a maximal length of 7 cm, in order to culture in vitro an adequate ureter replacement. With a rotating unit, (urothelial) cells can be placed homogeneously on the inner scaffold surface. Furthermore, a stimulation is combined with this bioreactor resulting in an orientation of muscle cells. These culturing methods request a precise control of several parameters and actuators. A combination of a LabBox and the suitable software LabVision is used to set and conduct parameters like rotation angles, velocities, pressures and other important cell culture values. The bioreactor was tested waterproof successfully. Furthermore, the temperature controlling was adjusted to 37 °C and the CO2 - concentration regulated to 5 %. Additionally, the pH step responses of several substances showed a perfect functioning of the designed flow chamber. All used software was tested and remained stable for several days. KW - Tissue Engineering KW - Bioreaktor KW - Organkultur KW - Harnleiter Y1 - 2011 ER - TY - THES A1 - Seifarth, Volker T1 - Ureteral tissue engineering : development of a bioreactor system and subsequent characterization of the generated biohybrids Y1 - 2015 N1 - Duisburg, Essen, Universität Duisburg-Essen, Diss., 2015 PB - Universitätsbibliothek Duisburg-Essen CY - Duisburg ; Essen ER - TY - JOUR A1 - Digel, Ilya A1 - Akimbekov, Nuraly S. A1 - Turalieva, M. A1 - Mansurov, Z. A1 - Temiz Artmann, Aysegül A1 - Eshibaev, A. A1 - Zhubanova, A. T1 - Usage of Carbonized Plant Wastes for Purification of Aqueous Solutions JF - Journal of Industrial Technology and Engineering Y1 - 2013 VL - 2 IS - 07 SP - 47 EP - 54 ER - TY - CHAP A1 - Zhubanova, Azhar A. A1 - Mansurov, Zulkhair A. A1 - Digel, Ilya T1 - Use of Advanced Nanomaterials for Bioremediation of Contaminated Ecosystems T2 - Carbon Nanomaterials in Biomedicine and the Environment N2 - This chapter shows that nanomaterials obtained by high-temperature carbonization of inexpensive plant raw material such as rice husk, grape seeds, and walnut shells can serve as a basis for the production of highly efficient microbial drugs, biodestructors, biosorbents, and biocatalysts, which are promising for the remediation of the ecosystem contaminated with heavy and radioactive metals, oil and oil products. A strong interest in engineering zymology is dictated by the necessity to address the issues of monitoring enzymatic processes, treatment, and diagnosis of a number of common human diseases, environmental pollution, quality control of pharmaceuticals and food. Nanomaterials obtained by high-temperature carbonization of cheap plant raw material such as-rice husks, grape seeds and walnut shells, can serve as a basis for creating of highly effective microbial preparations-biodestructors, biosorbents and biocatalysts, which are promising for the use of contaminated ecosystems, and for restoration of human intestine microecology. Y1 - 2020 SN - 978-981-4800-27-3 U6 - https://doi.org/10.1201/9780429428647-18 SP - 353 EP - 378 PB - Jenny Stanford Publishing CY - Singapore ER - TY - JOUR A1 - Akimbekov, Nuraly S. A1 - Zhubanova, A. A. A1 - Mansurov, Z. A. A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Temiz Artmann, Aysegül T1 - Use of Carbonized Rise Shell for the local treatment of wounds JF - Eurasian ChemTech Journal N2 - On the model of musculocutaneous wound in rats, the effect of applicative sorption by carbonized rise shell (CRS) on the healing of festering wound was studied. It has been shown, that cytological changes end with rapid scar formation. The use of CRS at the period of severe purulent wound contributes to its favorable course, prevents the development of complications of the animals from sepsis. Y1 - 2010 U6 - https://doi.org/10.18321/ectj35 SN - 2522-4867 VL - 12 IS - 2 SP - 133 EP - 138 PB - Institute of Combustion Problems CY - Almaty ER - TY - JOUR A1 - Siqueira, Jose R. A1 - Maki, Rafael M. A1 - Paulovich, Fernando V. A1 - Werner, Frederik A1 - Poghossian, Arshak A1 - Oliveira, Maria C. F. de A1 - Zucolotto, Valtencir A1 - Oliveira, Osvaldo N. Jr. A1 - Schöning, Michael Josef T1 - Use of information visualization methods eliminating cross talk in multiple sensing units investigated for a light-addressable potentiometric sensor JF - Analytical Chemistry N2 - The integration of nanostructured films containing biomolecules and silicon-based technologies is a promising direction for reaching miniaturized biosensors that exhibit high sensitivity and selectivity. A challenge, however, is to avoid cross talk among sensing units in an array with multiple sensors located on a small area. In this letter, we describe an array of 16 sensing units of a light-addressable potentiometric sensor (LAPS), which was made with layer-by-layer (LbL) films of a poly(amidomine) dendrimer (PAMAM) and single-walled carbon nanotubes (SWNTs), coated with a layer of the enzyme penicillinase. A visual inspection of the data from constant-current measurements with liquid samples containing distinct concentrations of penicillin, glucose, or a buffer indicated a possible cross talk between units that contained penicillinase and those that did not. With the use of multidimensional data projection techniques, normally employed in information visualization methods, we managed to distinguish the results from the modified LAPS, even in cases where the units were adjacent to each other. Furthermore, the plots generated with the interactive document map (IDMAP) projection technique enabled the distinction of the different concentrations of penicillin, from 5 mmol L−1 down to 0.5 mmol L−1. Data visualization also confirmed the enhanced performance of the sensing units containing carbon nanotubes, consistent with the analysis of results for LAPS sensors. The use of visual analytics, as with projection methods, may be essential to handle a large amount of data generated in multiple sensor arrays to achieve high performance in miniaturized systems Y1 - 2010 U6 - https://doi.org/10.1021/ac9024076 SN - 0003-2700 VL - 82 IS - 1 SP - 61 EP - 65 PB - ACS Publications CY - Washington ER - TY - JOUR A1 - Garhofer, Gerhard A1 - Bek, Toke A1 - Boehm, Andreas G. A1 - Gherghel, Doina A1 - Grundwald, Juan A1 - Jeppesen, Peter A1 - Kergoat, Hélène A1 - Kotliar, Konstantin A1 - Lanzl, Ines A1 - Lovasik, John V. A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Orgul, Selim A1 - Schmetterer, Leopold T1 - Use of the retinal vessel analyzer in ocular blood flow research JF - Acta Ophthalmol N2 - The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed. Y1 - 2010 U6 - https://doi.org/10.1111/j.1755-3768.2009.01587.x SN - 1755-3768 VL - 88 IS - 7 SP - 717 EP - 722 PB - Wiley-Blackwell CY - Oxford ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Stütz, Evamaria A1 - Fleischer, Maximilian A1 - Schöning, Michael Josef A1 - Wagner, Patrick T1 - Using a cell-based gas biosensor for investigation of adverse effects of acetone vapors in vitro JF - Biosensors and Bioelectronics. 40 (2013), H. 1 Y1 - 2013 SN - 0956-5663 SP - 393 EP - 400 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Schreiber, Marc A1 - Barkschat, Kai A1 - Kraft, Bodo T1 - Using Continuous Integration to organize and monitor the annotation process of domain specific corpora T2 - 5th International Conference on Information and Communication Systems (ICICS) : 1-3 April 2014, Irbid, Jordanien Y1 - 2014 SN - 978-1-4799-3022-7 U6 - https://doi.org/10.1109/IACS.2014.6841958 SP - 1 EP - 6 ER - TY - JOUR A1 - Zange, Jochen A1 - Schopen, Kathrin A1 - Albracht, Kirsten A1 - Gerlach, Darius A. A1 - Frings-Meuthen, Petra A1 - Maffiuletti, Nicola A. A1 - Bloch, Wilhelm A1 - Rittweger, Jörn T1 - Using the Hephaistos orthotic device to study countermeasure effectiveness of neuromuscular electrical stimulation and dietary lupin protein supplementation, a randomised controlled trial JF - Plos one Y1 - 2017 U6 - https://doi.org/10.1371/journal.pone.0171562 VL - 12 IS - 2 ER - TY - JOUR A1 - Wagner, Torsten A1 - Miyamoto, K. A1 - Werner, Frederik A1 - Schöning, Michael Josef A1 - Yoshinobu, T. T1 - Utilising Digital Micro-Mirror Device (DMD) as Scanning Light Source for Light-Addressable Potentiometric Sensors (LAPS) Y1 - 2011 U6 - https://doi.org/10.1166/sl.2011.1620 VL - 9 IS - 2 SP - 812 EP - 815 PB - American Scientific Publishers CY - Stevenson Ranch, Calif. ER - TY - CHAP A1 - Azar, Fouad A1 - Digel, Ilya ED - Staat, Manfred ED - Erni, Daniel T1 - Utilization of fluorescence spectroscopy and neural networks in clinical analysis T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - Fluorescence topography of human urine in combination with learning algorithms can provide a variant pattern recognition method in analytical clinical chemistry and, eventually, diagnosis. Y1 - 2019 SN - 978-3-940402-22-6 U6 - https://doi.org/10.17185/duepublico/48750 SP - 40 EP - 41 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Müller, Martin A1 - Hirschfeld, Julian A. A1 - Lambertz, Rita A1 - Schulze Lohoff, Andreas A1 - Lustfeld, Hans A1 - Pfeifer, Heinz A1 - Reißel, Martin T1 - Validation of a novel method for detecting and stabilizing malfunctioning areas in fuel cell stacks JF - Journal of power sources N2 - In this paper a setup for detecting malfunctioning areas of MEAs in fuel cell stacks is described. Malfunctioning areas generate electric cross currents inside bipolar plates. To exploit this we suggest bipolar plates consisting not of two but of three layers. The third one is a highly conducting layer and segmented such that the cross currents move along the segments to the surface of the stack where they can be measured by an inductive sensor. With this information a realistic model can be used to detect the malfunctioning area. Furthermore the third layer will prevent any current inhomogeneity of a malfunctioning cell to spread to neighbouring cells in the stack. In this work the results of measurements in a realistic cell setup will be compared with the results obtained in simulation studies with the same configuration. The basis for the comparison is the reliable characterisation of the electrical properties of the cell components and the implication of these results into the simulation model. The experimental studies will also show the limits in the maximum number of segments, which can be used for a reliable detection of cross currents. Y1 - 2014 U6 - https://doi.org/10.1016/j.jpowsour.2014.08.045 SN - 1873-2755 (E-Journal); 0378-7753 (Print) VL - 272 SP - 225 EP - 232 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ziemons, Karl A1 - Heinrichs, U. A1 - Streun, M. A1 - Pietrzyk, Uwe T1 - Validation of GEANT3 simulation studies with a dual-head PMT ClearPET™ prototype JF - 2003 IEEE Nuclear Science Symposium Conference Record, Vol. 5 N2 - The ClearPET™ project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2nd generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET™ camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41±0.11)mm compared to the measured of (1.48±0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. Y1 - 2004 SN - 1082-3654 SP - 3053 EP - 3056 ER -