TY - JOUR A1 - Dues, M. A1 - Gebhardt, Andreas A1 - Kallweit, Stephan A1 - Scheffler, T. A1 - Siekmann, H. A1 - Uchiyama, T. T1 - Flow Visualization in a Cavitating Flow JF - Proceedings of the German-Japanese Symposium on Multi-Phase Flow : Karlsruhe, Germany, August 23 - 25, 1994 / comp. by U. Müller ... Y1 - 1994 N1 - German Japanese Symposium on Multi-Phase Flow <1994, Karlsruhe> ; Kernforschungszentrum Karlsruhe ; 5389 SP - 391 EP - 402 PB - Kernforschungszentrum Karlsruhe CY - Karlsruhe ER - TY - JOUR A1 - Hillgärtner, Michael A1 - Peier, Dirk T1 - Design of a Measurement Setup for the Impedance of Low-Resistance Plate-Conductors in the RF-Range JF - Proceedings of the 10th International Conference on Optimization of Electrical and Electronic Equipment, OPTIM '06, Braşov, May 18 - 20, 2006 / ed. by The Transilvania University of Braşov, Faculty of Electrical Engineering and Computer Science. [Ed. Mihai Cernat .̤] . - Vol. 1: Keynote addresses, electrotechnics Y1 - 2006 SN - 978-973-635703-9 N1 - International Conference on Optimization of Electrical and Electronic Equipment <10, 2006, Braşov>; OPTIM <10, 2006, Braşov> SP - 59 EP - 64 CY - Braşov ER - TY - JOUR A1 - Hillgärtner, Michael A1 - Stonies, R. A1 - Peier, D. A1 - Voges, E. T1 - Design of Low Cost Antennas for Reverberation Chambers JF - Proceedings of the 16th International Zurich Symposium on Electromagnetic Compatibility : [EMC Week 2005, Zurich, Switzerland, February 13 - 18 ; technical exhibition on EMC and RF/microwave Measurements and Instrumentation (February 15 - 17)] / [Laboratory for Electromagnetic Fields and Microwave Electronics, Swiss Federal Institute of Technology Zurich] Y1 - 2005 SN - 3-9521199-9-7 N1 - Nebent.: EMC Zurich 2005 Symposium proceedings. - International Zurich Symposium and Technical Exhibition on Electromagnetic Compatibility <16, 2005, Zürich> Institut für Feldtheorie und Höchstfrequenztechnik PB - ETH-Zentrum-IFH CY - Zürich ER - TY - JOUR A1 - Hillgärtner, Michael A1 - Kappel, U. T1 - Radiating Impedance of Mains Cabling During Emissions Testing JF - EMC Europe 2006 Barcelona : International Symposium on Electromagnetic Compatibility; September 4 - 8, 2006, Campus Nord, Technical University of Catalonia, Barcelona, Spain / [organized by Technical University of Catalonia (UPC) ... Ed. and publ. by: Ferran Silva ...]. - Vol. 1: Proceedings 1 Y1 - 2006 SN - 84-689-9439-1 N1 - EMC Europe <7,2006,Barcelona>; International Symposium on Electromagnetic Compatibility <7, 2006, Barcelona> SP - 17 EP - 22 CY - Barcelona ER - TY - JOUR A1 - Hüning, Felix A1 - Jaekel, C. A1 - Francois, I. A1 - Kyas, G. T1 - Microwave surface impedance measurements on high-Tc superconductors / Jaekel, C. ; Francois, I. ; Kyas, G. ; Hüning, F. ; Roskos, H. G. ; Borghs, G. ; Kurz, H. JF - Czechoslovak Journal of Physics. 46 (1996), H. Suppl. 2 Y1 - 1996 SN - 1572-9486 IS - 46 SP - 1117 EP - 1118 PB - Springer Science+Business Media CY - Dordrecht ER - TY - JOUR A1 - Hirschberg, Rainer T1 - Decentral pumps in heating systems - a new hydraulic approac JF - 1st International Rotating Equipment Conference - Pumps and Compressors, 9th Pump Users International Forum, 9. Internationales Pumpenanwenderforum, Final Report, Düsseldorf, DE, 28.-29. Oct, 2008 Y1 - 2008 SP - 1 EP - 10 PB - - ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Kirsanov, Dmitry A1 - Legin, Andrey A1 - Osterrath, Thomas A1 - Schubert, Jürgen A1 - Zander, Willi A1 - Schöning, Michael Josef T1 - Development of a thin-film sensor array for analytical monitoring of heavy metals in aqueous solutions JF - Physica Status Solidi (a) N2 - In industrial processes there is a variety of heavy metals (e.g., copper, zinc, cadmium, and lead) in use for wires, coatings, paints, alloys, batteries, etc. Since the application of these transition metals for industry is inevitable, it is a vital task to develop proper analytical techniques for their monitoring at low activity levels, especially because most of these elements are acutely toxic for biological organisms. The determination of ions in solution by means of a simple and inexpensive sensor array is, therefore, a promising task. In this work, a sensor array with heavy metal-sensitive chalcogenide glass membranes for the simultaneous detection of the four ions Ag⁺, Cu2⁺, Cd2⁺, and Pb2⁺ in solution is realized. The results of the physical characterization by means of microscopy, profilometry, Rutherford backscattering spectroscopy (RBS), and scanning electron microscopy (SEM) as well as the electrochemical characterization by means of potentiometric measurements are presented. Additionally, the possibility to expand the sensor array by polymeric sensor membranes is discussed. Y1 - 2012 SN - 1862-6319 U6 - https://doi.org/10.1002/pssa.201100733 VL - 209 IS - 5 SP - 885 EP - 891 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Engels, Elmar A1 - Krauskopf, S. T1 - Innovation in Motion-Logic programming - a versatile interface JF - Proceedings to the 12th International Workshop on Research and Education in Mechatronics, REM 2011, Kocaeli, Turkey, 15.09.-16.09.2011 Y1 - 2011 SN - 978-975-8047-96-3 PB - - ER - TY - JOUR A1 - Spelthahn, Heiko A1 - Schubert, Jürgen A1 - Schöning, Michael Josef T1 - Dünnschichtsensoren für die Schwermetallanalytik JF - GIT : Labor-Fachzeitschrift N2 - Die Detektion von Schadstoffen repräsentiert in der Umweltanalytik eine wichtige Aufgabenstellung. Gerade die Abwasser- bzw. Brauchwasseranalytik sowie die Prozesskontrolle haben einen hohen Stellenwert. Siliziumbasierte Dünnschichtsensoren bieten eine kostengünstige Möglichkeit, „online“-Messungen bzw. Vor-Ort-Messungen zeitnah durchzuführen. In dieser Arbeit wird ein potentiometrisches Sensorarray auf der Basis von Chalkogenidgläsern zur Detektion von Schwermetallen in wässrigen Medien vorgestellt. Y1 - 2012 SN - 0016-3538 VL - 56 IS - 4 SP - 285 EP - 287 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Lanzl, Ines M. T1 - Can vascular function be assessed by the interpretation of retinal vascular diameter changes? JF - Investigative Ophthalmology & Visual Science, IOVS. 52 (2011), H. 1 Y1 - 2011 SN - 0146-0404 SP - 635 EP - 636 PB - ARVO CY - Rockville, Md. ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Mücke, Bruno A1 - Vilser, Walthard A1 - Schilling, Rudolf T1 - Effect of aging on retinal artery blood column diameter measured along the vessel axis / Kotliar, Konstantin E. ; Mücke, Bruno ; Vilser, Walthard ; Schilling, Rudolf ; Lanzl, Ines M. JF - Investigative Ophthalmology & Visual Science, IOVS. 49 (2008), H. 5 Y1 - 2008 SN - 0146-0404 SP - 2094 EP - 2102 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Lanzl, Ines M. A1 - Hanssen, Henner A1 - Eberhardt, Karla A1 - Vilser, Walthard A1 - Halle, Martin A1 - Heemann, Uwe A1 - Schmidt-Trucksäss, Arno A1 - Baumann, Marcus T1 - Does increased blood pressure rather than aging influence retinal pulse wave velocity? JF - Investigative Ophthalmology & Visual Science, IOVS N2 - Purpose: It was demonstrated previously that retinal pulse wave velocity (rPWV) as a measure of retinal arterial stiffness is increased in aged anamnestically healthy volunteers compared with young healthy subjects. Using novel methodology of rPWV assessment this finding was confirmed and investigated whether it might relate to the increased blood pressure usually accompanying the aging process, rather than to the aging itself. Methods: A total of 12 young 25.5-year-old (24.0–28.8) [median(1st quartile–3rd quartile)] and 12 senior 68.5-year-old (63.8–71.8) anamnestically healthy volunteers; and 12 senior 63.0-year-old (60.8–65.0) validated healthy volunteers and 12 young 33.0-year-old (29.5–35.0) hypertensive patients were examined. Time-dependent alterations of vessel diameter were assessed by the Dynamic Vessel Analyzer in a retinal artery of each subject. The data were filtered and processed using mathematical signal analysis and rPWVs were calculated. Results: rPWV amounted to 1200 (990-1470) RU (relative units)/s in the hypertensive group and to 1040 (700-2230) RU/s in anamnestically healthy seniors. These differed significantly from rPWVs in young healthy group (410 [280–500] RU/s) and in validated healthy seniors (400 [320–510] RU/s). rPWV associated with age and mean arterial pressure (MAP) in the pooled cohort excluded validated healthy seniors. In a regression model these associations remain when alternately adjusted for MAP and age. When including validated healthy seniors in the pooled cohort only association with MAP remains. Conclusions: Both aging (with not excluded cardiovascular risk factors) and mild hypertension are associated with elevated rPWV. rPWV increases to a similar extent both in young mildly hypertensive subjects and in aged anamnestically healthy persons. Healthy aging is not associated with increased rPWV. Y1 - 2012 U6 - https://doi.org/10.1167/iovs.11-8815 SN - 0146-0404 VL - 53 IS - 4 SP - 2119 EP - 2126 PB - ARVO CY - Rockville, Md. ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Seidova, Seid-Fatima A1 - Lanzl, Ines T1 - Microstructural alterations of retinal arterial blood column along the vessel axis in systemic hypertension JF - Investigative Ophthalmology & Visual Science, IOVS N2 - Purpose: Image analysis by the retinal vessel analyzer (RVA) observes retinal vessels in their dynamic state online noninvasively along a chosen vessel segment. It has been found that high-frequency diameter changes in the retinal artery blood column along the vessel increase significantly in anamnestically healthy volunteers with increasing age and in patients with glaucoma during vascular dilation. This study was undertaken to investigate whether longitudinal sections of the retinal artery blood column are altered in systemic hypertension. Methods: Retinal arteries of 15 untreated patients with essential arterial hypertension (age, 50.9 ± 11.9 years) and of 15 age-matched anamnestically healthy volunteers were examined by RVA. After baseline assessment, a monochromatic luminance flicker (530–600 nm; 12.5 Hz; 20 s) was applied to evoke retinal vasodilation. Differences in amplitude and frequency of spatial artery blood column diameter change along segments (longitudinal arterial profiles) of 1 mm in length were measured and analyzed using Fourier transformation. Results: In the control group, average reduced power spectra (ARPS) of longitudinal arterial profiles did not differ when arteries changed from constriction to dilation. In the systemic hypertension group, ARPS during constriction, baseline, and restoration were identical and differed from ARPS during dilation (P < 0.05). Longitudinal arterial profiles in both groups showed significant dissimilitude at baseline and restoration (P < 0.05). Conclusions: The retinal artery blood column demonstrates microstructural alterations in systemic hypertension and is less irregular along the vessel axis during vessel dilation. These microstructural changes may be an indication of alterations in vessel wall rigidity, vascular endothelial function, and smooth muscle cells in this disease, leading to impaired perfusion and regulation. Y1 - 2010 U6 - https://doi.org/10.1167/iovs.09-3649 SN - 0146-0404 VL - 51 IS - 4 SP - 2165 EP - 2172 PB - ARVO CY - Rockville, Md. ER - TY - JOUR A1 - Lanzl, Ines M. A1 - Seidova, Seid-Fatima A1 - Maier, Mathias A1 - Schmidt-Trucksäss, Arno A1 - Halle, Martin A1 - Kotliar, Konstantin T1 - Dynamic retinal vessel response to flicker in age-related macular degeneration patients before and after vascular endothelial growth factor inhibitor injection JF - Acta Ophthalmologica Y1 - 2011 SN - 1755-3768 VL - 89 IS - 5 SP - 472 EP - 479 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Maier, Mathias A1 - Bauer, Svetlana A1 - Feucht, Nikolaus A1 - Lohmann, Chris A1 - Lanzl, Ines T1 - Intravitreal injection of triamcinolone acetonide and intraocular pressure: author's reply JF - Acta Ophthalmologica Y1 - 2008 SN - 1755-3768 VL - 86 IS - 6 SP - 692 EP - 693 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Nagel, Edgar A1 - Vilser, Walthard A1 - Lanzl, Ines M. T1 - Functional in vivo assessment of retinal artery microirregularities in glaucoma / Kotliar, Konstantin E. ; Nagel, Edgar ; Vilser, Walthard ; Lanzl, Ines M. JF - Acta Ophthalmologica. 86 (2008), H. 4 Y1 - 2008 SN - 1755-3768 SP - 424 EP - 433 PB - - ER - TY - JOUR A1 - Kotliar, Konstantin A1 - Maier, Mathias A1 - Bauer, Svetlana A1 - Feucht, Nikolaus T1 - Effect of intravitreal injections and volume changes on intraocular pressure: clinical results and biomechanical model / Kotliar, Konstantin ; Maier, Mathias ; Bauer, Svetlana ; Feucht, Nikolaus ; Lohmann, Chris ; Lanzl, Ines JF - Acta Ophthalmologica Scandinavica. 85 (2007), H. 7 Y1 - 2007 SN - 1755-3768 SP - 777 EP - 781 PB - - ER - TY - JOUR A1 - Bohrn, U. A1 - Stütz, E. A1 - Fuchs, K. A1 - Fleischer, M. A1 - Schöning, Michael Josef A1 - Wagner, P. T1 - Monitoring of irritant gas using a whole-cell-based sensor system JF - Sensors and Actuators B: Chemical N2 - Cell-based sensors for the detection of gases have long been underrepresented, due to the cellular requirement of being cultured in a liquid environment. In this work we established a cell-based gas biosensor for the detection of toxic substances in air, by adapting a commercial sensor chip (Bionas®), previously used for the measurement of pollutants in liquids. Cells of the respiratory tract (A549, RPMI 2650, V79), which survive at a gas phase in a natural context, are used as biological receptors. The physiological cell parameters acidification, respiration and morphology are continuously monitored in parallel. Ammonia was used as a highly water-soluble model gas to test the feasibility of the sensor system. Infrared measurements confirmed the sufficiency of the medium draining method. This sensor system provides a basis for many sensor applications such as environmental monitoring, building technology and public security. Y1 - 2012 U6 - https://doi.org/10.1016/j.snb.2012.05.088 SN - 0925-4005 VL - 175 SP - 208 EP - 217 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hillen, Walter A1 - Alper Selver, M. A1 - Fischer, Felix A1 - Kuntalp, Mehmet T1 - A software tool for interactive generation, representation, and systematical storage of transfer functions for 3D medical images / Alper Selver, M. ; Fischer, Felix ; Kuntalp, Mehmet ; Hillen, Walter JF - Computer Methods and Programs in Biomedicine. 86 (2007), H. 3 Y1 - 2007 SN - 0169-2607 SP - 270 EP - 280 PB - - ER - TY - JOUR A1 - Hüning, Felix A1 - Wilke, I. A1 - Nakielski, G. A1 - Kotzler, J. T1 - Dynamic conductivity of YBCO thin films from low to very high frequencies / Wilke, I. ; Nakielski, G. ; Kotzler, J. ; Subke, K. O. ; Jaekel, C. ; Hüning, F. ; Roskos, H. G. ; Kurz, Heinrich JF - Applied superconductivity 1997 : proceedings of EUCAS 1997, the Third European Conference on Applied Superconductivity, held in the Netherlands, 30 June - 3 July 1997 / ed. by H. Rogalla Y1 - 1997 SN - 0-7503-0487-1 N1 - Institute of Physics conference series 158 SP - 121 EP - 124 PB - IOP CY - Bristol ER -