TY - JOUR A1 - Agrafiotis, Christos C. A1 - Mavroidis, Ilias A1 - Konstandopoulos, Athansios G. A1 - Hoffschmidt, Bernhard A1 - Stobbe, Per A1 - Romero, Manuel A1 - Fernandez-Quero, Valerio T1 - Evaluation of porous silicon carbide monolithic honeycombs as volumetric receivers/collectors of concentrated solar radiation JF - Solar energy materials and solar cells Y1 - 2007 SN - 1879-3398 (E-Journal); 0927-0248 (Print) VL - Vol. 91 IS - Iss. 6 SP - 474 EP - 488 ER - TY - JOUR A1 - Aggeloussis, Nickos A1 - Giannakou, Erasmia A1 - Albracht, Kirsten A1 - Arampatzis, Adamantios T1 - Reproducibility of fascicle length and pennation angle of gastrocnemius medialis in human gait in vivo JF - Gait and Posture N2 - The purpose of the current study was to examine the reproducibility of fascicle length and pennation angle of gastrocnemius medialis while human walking. To the best of our knowledge, this is the first study of the reproducibility of fascicle length and pennation angle of gastrocnemius medialis in vivo during human gait. Twelve males performed 10 gait trials on a treadmill, in 2 separate days. B-mode ultrasonography, with the ultrasound probe firmly adjusted in the transverse and frontal planes using a special cast, was used to measure the fascicle length and the pennation angle of the gastrocnemius medialis (GM). A Vicon 624 system with three cameras operating at 120 Hz was also used to record the ankle and knee joint angles. The results showed that measurements of fascicle length and pennation angle showed high reproducibility during the gait cycle, both within the same day and between different days. Moreover, the root mean square differences between the repeated waveforms of both variables were very small, compared with their ranges (fascicle length: RMS = ∼3 mm, range: 38–63 mm; pennation angle: RMS = ∼1.5°, range: 22–32°). However, their reproducibility was lower compared to the joint angles. It was found that representative data have to be derived by a wide number of gait trials (fascicle length ∼six trials, pennation angle more than 10 trials), to assure the reliability of the fascicle length and pennation angle in human gait. Y1 - 2010 U6 - https://doi.org/10.1016/j.gaitpost.2009.08.249 SN - 0966-6362 VL - 31 IS - 1 SP - 73 EP - 77 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Aggarwal, Prerna A1 - Singh, Virendra A1 - Singh, Arjun A1 - Scherer, Ulrich W. A1 - Singh, Tejvir A1 - Singla, Madan L. A1 - Srivastava, Alok T1 - Physico-chemical transformations in swift heavy ion modified poly(ethyleneterephthalate) JF - Radiation Physics and Chemistry Y1 - 2011 SN - 0969-806X N1 - In Press, Accepted Manuscript SP - 1 EP - 28 PB - Pergamon Press CY - Oxford ER - TY - JOUR A1 - Aggarwal, P. A1 - Dhiman, S. A1 - Kumar, G. A1 - Scherer, Ulrich W. A1 - Singla, M. L. A1 - Srivastava, A. T1 - Optical study of poly(ethyleneterephthalate) modified by different ionizing radiation dose JF - Indian Journal of Pure and Applied Physics N2 - Thin films of poly(ethyleneterephthalate) [PET]were exposed to radiation dose ranging from 10 to 30 kGy by using gamma rays in the range 12.8-177.8 MGy using swift light ions of hydrogen. There was no effect of the radiation dose on the optical behaviour of PET as a result of exposure to radiation dose up to 30 kGy brought about by gamma rays but a significant decrease in the optical band gap values was observed when PET was exposed to swift light ions of hydrogen. The data obtained are discussed in terms of optical studies carried out on PET using swift heavy ions. Y1 - 2012 SN - 0019-5596 VL - 50 IS - 2 SP - 129 EP - 132 ER - TY - CHAP A1 - Adomeit, G. A1 - Willms, Herbert ED - Skupinski, Edwin T1 - Experimental investigation of the acceleration of deflagration in wake flow T2 - Safety of thermal water reactors : proceedings of a Seminar on the Results of the European Communities’ Indirect Action Research Programme on Safety of Thermal Water Reactors, held in Brussels, 1–3 October 1984 / Commission of the European Communities Y1 - 1984 SN - 0-86010-678-0 SN - 978-94-009-4972-0 (Online-Nachdr. vom Springer-Verl.) N1 - Forschungsvorhaben Nr. 024 SRD SP - 294 EP - 304 PB - Graham & Trotman [u.a.] CY - London Gaithersburg, Md. ER - TY - RPRT A1 - Adomeit, G. A1 - Willms, Herbert T1 - Experimental investigation of the acceleration of deflagration in wake flow : final report. - (Euratom-publications-EUR ; 9593 : Nuclear science and technology) Y1 - 1984 SN - 92-825-4699-3 PB - Commission of the European Communities CY - Luxembourg ER - TY - JOUR A1 - Adels, Klaudia A1 - Monakhova, Yulia T1 - Low-field NMR spectroscopic study of e-cigarettes: Is determination of only nicotine and organic carrier solvents possible? JF - Microchemical Journal N2 - Electronic cigarettes (e-cigarettes) have become popular worldwide with the market growing exponentially in some countries. The absence of product standards and safety regulations requires urgent development of analytical methodologies for the holistic control of the growing diversity of such products. An approach based on low-field nuclear magnetic resonance (LF-NMR) at 80 MHz is presented for the simultaneous determination of key parameters: carrier solvents (vegetable glycerine (VG), propylene glycol (PG) and water), total nicotine as well as free-base nicotine fraction. Moreover, qualitative and quantitative determination of fourteen weak organic acids deliberately added to enhance sensory characteristics of e-cigarettes was possible. In most cases these parameters can be rapidly and conveniently determined without using any sample manipulation such as dilution, extraction or derivatization steps. The method was applied for 37 authentic e-cigarettes samples. In particular, eight different organic acids with the content up to 56 mg/mL were detected. Due to its simplicity, the method can be used in routine regulatory control as well as to study release behaviour of nicotine and other e-cigarettes constituents in different products. KW - Electronic cigarettes KW - Low field NMR KW - Carrier solvents KW - Free-base nicotine KW - Weak organic acids Y1 - 2024 U6 - https://doi.org/10.1016/j.microc.2024.110859 SN - 1095-9149 N1 - Corresponding author: Yulia Monakhova VL - 203 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Adels, Klaudia A1 - Elbers, Gereon A1 - Diehl, Bernd A1 - Monakhova, Yulia T1 - Multicomponent analysis of dietary supplements containing glucosamine and chondroitin: comparative low- and high-field NMR spectroscopic study JF - Analytical Sciences N2 - With the prevalence of glucosamine- and chondroitin-containing dietary supplements for people with osteoarthritis in the marketplace, it is important to have an accurate and reproducible analytical method for the quantitation of these compounds in finished products. NMR spectroscopic method based both on low- (80 MHz) and high- (500–600 MHz) field NMR instrumentation was established, compared and validated for the determination of chondroitin sulfate and glucosamine in dietary supplements. The proposed method was applied for analysis of 20 different dietary supplements. In the majority of cases, quantification results obtained on the low-field NMR spectrometer are similar to those obtained with high-field 500–600 MHz NMR devices. Validation results in terms of accuracy, precision, reproducibility, limit of detection and recovery demonstrated that the developed method is fit for purpose for the marketed products. The NMR method was extended to the analysis of methylsulfonylmethane, adulterant maltodextrin, acetate and inorganic ions. Low-field NMR can be a quicker and cheaper alternative to more expensive high-field NMR measurements for quality control of the investigated dietary supplements. High-field NMR instrumentation can be more favorable for samples with complex composition due to better resolution, simultaneously giving the possibility of analysis of inorganic species such as potassium and chloride. KW - Glucosamine KW - Chondroitin sulfate KW - Polysaccharides KW - Dietary supplements KW - High-field NMR Y1 - 2023 U6 - https://doi.org/10.1007/s44211-023-00433-2 SN - 1348-2246 (Online) SN - 0910-6340 (Print) N1 - Corresponding author: Yulia Monakhova VL - 2023 PB - Springer Verlag CY - Cham ER - TY - CHAP A1 - Adams, Moritz A1 - Losekamm, Martin J. A1 - Czupalla, Markus T1 - Development of the Thermal Control System for the RadMap Telescope Experiment on the International Space Station T2 - International Conference on Environmental Systems Y1 - 2020 N1 - 2020 International Conference on Environmental Systems, 12. Juli 2020 – 16. Juli 2020, Lissabon SP - 1 EP - 10 ER - TY - JOUR A1 - Ackermann, Hans-Josef A1 - Jäger, Michael A1 - Osterfeld, Utz A1 - Hornung, Christoph T1 - Building a Multimedia ISDN PC / Jäger, Michael ; Osterfeld, Utz ; Ackermann, Hans-Josef ; Hornung, Christoph JF - Institute of Electrical and Electronics Engineers: IEEE computer graphics and applications. 13 (1993), H. 5 Y1 - 1993 SN - 0272-1716 SP - 24 EP - 33 ER - TY - JOUR A1 - Ackermann, Hans-Josef T1 - Single chip hardware support for rasterization and texture mapping JF - Computers & graphics : CAG ; an international journal of applications in computer graphics. 20 (1996), H. 4 Y1 - 1996 SN - 0097-8493 SP - 503 EP - 514 ER - TY - JOUR A1 - Ackermann, Hans-Josef T1 - Morphing- und Level-of-Detail-Techniken zur Reduzierung des Darstellungsaufwands bei Echtzeit-Sichtsimulationen JF - Digital controls for high resolution display : JESSI Europrojekt No. 3203000, AE-36 ; Abschlußbericht ; Laufzeit u. Berichtszeitraum: 01.01.1995 bis 31.12.1996. Y1 - 1997 CY - Erlangen ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Tödter, Julia A1 - Niehues, Julia A1 - Telöken, Matthias A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim A1 - Schröper, Florian T1 - 3D printed modular immunofiltration columns for frequency mixing-based multiplex magnetic immunodetection JF - Sensors N2 - For performing point-of-care molecular diagnostics, magnetic immunoassays constitute a promising alternative to established enzyme-linked immunosorbent assays (ELISA) because they are fast, robust and sensitive. Simultaneous detection of multiple biomolecular targets from one body fluid sample is desired. The aim of this work is to show that multiplex magnetic immunodetection based on magnetic frequency mixing by means of modular immunofiltration columns prepared for different targets is feasible. By calculations of the magnetic response signal, the required spacing between the modules was determined. Immunofiltration columns were manufactured by 3D printing and antibody immobilization was performed in a batch approach. It was shown experimentally that two different target molecules in a sample solution could be individually detected in a single assaying step with magnetic measurements of the corresponding immobilization filters. The arrangement order of the filters and of a negative control did not influence the results. Thus, a simple and reliable approach to multi-target magnetic immunodetection was demonstrated. Y1 - 2019 U6 - https://doi.org/10.3390/s19010148 SN - 1424-8220 VL - 19 IS - 1 PB - MDPI CY - Basel ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Schönenborn, Kristina A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Measurement of the magnetophoretic velocity of different superparamagnetic beads JF - Journal of Magnetism and Magnetic Materials N2 - The movement of magnetic beads due to a magnetic field gradient is of great interest in different application fields. In this report we present a technique based on a magnetic tweezers setup to measure the velocity factor of magnetically actuated individual superparamagnetic beads in a fluidic environment. Several beads can be tracked simultaneously in order to gain and improve statistics. Furthermore we show our results for different beads with hydrodynamic diameters between 200 and 1000 nm from diverse manufacturers. These measurement data can, for example, be used to determine design parameters for a magnetic separation system, like maximum flow rate and minimum separation time, or to select suitable beads for fixed experimental requirements. KW - magnetophoretic velocity KW - superparamagnetic bead KW - magnetic tweezers KW - magnetic separation KW - magnetic actuation Y1 - 2019 U6 - https://doi.org/10.1016/j.jmmm.2018.10.066 SN - 0304-8853 VL - 477 IS - 1 SP - 244 EP - 248 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Pourshahidi, Ali Mohammad A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim T1 - Multiplex detection of different magnetic beads using frequency scanning in magnetic frequency mixing technique JF - Sensors N2 - In modern bioanalytical methods, it is often desired to detect several targets in one sample within one measurement. Immunological methods including those that use superparamagnetic beads are an important group of techniques for these applications. The goal of this work is to investigate the feasibility of simultaneously detecting different superparamagnetic beads acting as markers using the magnetic frequency mixing technique. The frequency of the magnetic excitation field is scanned while the lower driving frequency is kept constant. Due to the particles’ nonlinear magnetization, mixing frequencies are generated. To record their amplitude and phase information, a direct digitization of the pickup-coil’s signal with subsequent Fast Fourier Transformation is performed. By synchronizing both magnetic beads using frequency scanning in magnetic frequency mixing technique magnetic fields, a stable phase information is gained. In this research, it is shown that the amplitude of the dominant mixing component is proportional to the amount of superparamagnetic beads inside a sample. Additionally, it is shown that the phase does not show this behaviour. Excitation frequency scans of different bead types were performed, showing different phases, without correlation to their diverse amplitudes. Two commercially available beads were selected and a determination of their amount in a mixture is performed as a demonstration for multiplex measurements. KW - frequency mixing magnetic detection KW - magnetic sandwich immunoassay KW - multiparametric immunoassays Y1 - 2019 U6 - https://doi.org/10.3390/s19112599 SN - 1424-8220 VL - 19 IS - 11 PB - MDPI CY - Basel ER - TY - JOUR A1 - Achtsnicht, Stefan A1 - Neuendorf, Christian A1 - Faßbender, Tobias A1 - Nölke, Greta A1 - Offenhäusser, Andreas A1 - Krause, Hans-Joachim A1 - Schröper, Florian T1 - Sensitive and rapid detection of cholera toxin subunit B using magnetic frequency mixing detection JF - Plos One N2 - Cholera is a life-threatening disease caused by the cholera toxin (CT) as produced by some Vibrio cholerae serogroups. In this research we present a method which directly detects the toxin’s B subunit (CTB) in drinking water. For this purpose we performed a magnetic sandwich immunoassay inside a 3D immunofiltration column. We used two different commercially available antibodies to capture CTB and for binding to superparamagnetic beads. ELISA experiments were performed to select the antibody combination. The beads act as labels for the magnetic frequency mixing detection technique. We show that the limit of detection depends on the type of magnetic beads. A nonlinear Hill curve was fitted to the calibration measurements by means of a custom-written python software. We achieved a sensitive and rapid detection of CTB within a broad concentration range from 0.2 ng/ml to more than 700 ng/ml. Y1 - 2019 U6 - https://doi.org/10.1371/journal.pone.0219356 SN - 1932-6203 VL - 14 IS - 7 PB - Plos CY - San Francisco ER - TY - CHAP A1 - Achenbach, Timm A1 - Göttsche, Joachim A1 - Kaufhold, O. A1 - Hoffschmidt, Bernhard T1 - Development of an edge module for open volumetric receiver for the use of the radiation at the receiver boundary region T2 - SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain Y1 - 2011 CY - Granada ER - TY - CHAP A1 - Achenbach, Timm A1 - Geimer, Konstantin A1 - Lynen, Arthur A1 - Göttsche, Joachim A1 - Hoffschmidt, Bernhard T1 - Simulation of thermo-mechanical processes in open volumetric absorber modules T2 - SolarPaces 2012 : concentrating solar power and chemical energy systems : Sept. 11 - 14 2012, Marrakech, Marokko Y1 - 2012 SP - 1 EP - 8 ER - TY - CHAP A1 - Achenbach, Timm A1 - Geimer, K. A1 - Göttsche, Joachim A1 - Hoffschmidt, Bernhard A1 - Lynen, A. A1 - Bauer, J. T1 - Simulation and flow measurements of volumetric high temperature absorbers for solar tower power plants T2 - SolarPACES 2011 : concentrating solar power and chemical energy systems : 20 - 23 September, 2011, Granada, Spain Y1 - 2011 CY - Granada ER - TY - CHAP A1 - Achenbach, Timm A1 - Bosch, Timo A1 - Breitbach, Gerd A1 - Göttsche, Joachim A1 - Sauerborn, Markus T1 - Theoretical and experimental investigations regarding open volumetric receivers of CRS T2 - Energy procedia : proceedings of the SolarPACES 2013 International Conference Y1 - 2013 SN - 1876-6102 VL - Vol. 49 SP - 1259 EP - 1268 ER -