TY - JOUR A1 - Kirchner, Patrick A1 - Oberländer, Jan A1 - Suso, Henri-Pierre A1 - Rysstad, Gunnar A1 - Keusgen, Michael A1 - Schöning, Michael Josef T1 - Towards a wireless sensor system for real-time H2O2 monitoring in aseptic food processes JF - Physica status solidi (a) N2 - A wireless sensor system based on the industrial ZigBee standard for low-rate wireless networking was developed that enables real-time monitoring of gaseous H2O2 during the package sterilization in aseptic food processes. The sensor system consists of a remote unit connected to a calorimetric gas sensor, which was already established in former works, and an external base unit connected to a laptop computer. The remote unit was built up by an XBee radio frequency (RF) module for data communication and a programmable system-on-chip controller to read out the sensor signal and process the sensor data, whereas the base unit is a second XBee RF module. For the rapid H2O2 detection on various locations inside the package that has to be sterilized, a novel read-out strategy of the calorimetric gas sensor was established, wherein the sensor response is measured within the short sterilization time and correlated with the present H2O2 concentration. In an exemplary measurement application in an aseptic filling machinery, the suitability of the new, wireless sensor system was demonstrated, wherein the influence of the gas velocity on the H2O2 distribution inside a package was determined and verified with microbiological tests. KW - calorimetric gas sensor;hydrogen peroxide;wireless sensor system Y1 - 2013 U6 - https://doi.org/10.1002/pssa.201200920 SN - 1862-6319 VL - 210 IS - 5 SP - 877 EP - 883 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Khodaverdi, M. A1 - Chatziioannou, A. F. A1 - Weber, S. A1 - Ziemons, Karl A1 - Halling, H. A1 - Pietrzyk, U. T1 - Investigation of different MicroCT scanner configurations by GEANT4 simulations JF - IEEE Transactions on Nuclear Science N2 - This study has been performed to design the combination of the new ClearPET (ClearPET is a trademark of the Crystal Clear Collaboration), a small animal positron emission tomography (PET) system, with a micro-computed tomography (microCT) scanner. The properties of different microCT systems have been determined by simulations based on GEANT4. We will demonstrate the influence of the detector material and the X-ray spectrum on the obtained contrast. Four different detector materials (selenium, cadmium zinc telluride, cesium iodide and gadolinium oxysulfide) and two X-ray spectra (a molybdenum and a tungsten source) have been considered. The spectra have also been modified by aluminum filters of varying thickness. The contrast between different tissue types (water, air, brain, bone and fat) has been simulated by using a suitable phantom. The results indicate the possibility to improve the image contrast in microCT by an optimized combination of the X-ray source and detector material. Y1 - 2005 SN - 0018-9499 VL - 52 IS - 1 SP - 188 EP - 192 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - The data acquisition system of ClearPET neuro - a small animal PET scanner JF - IEEE Transactions on Nuclear Science N2 - The Crystal Clear Collaboration has developed a modular system for a small animal PET scanner (ClearPET). The modularity allows the assembly of scanners of different sizes and characteristics in order to satisfy the specific needs of the individual member institutions. The system performs depth of interaction detection by using a phoswich arrangement combining LSO and LuYAP scintillators which are coupled to Multichannel Photomultipliers (PMTs). For each PMT a free running 40 MHz ADC digitizes the signal and the complete scintillation pulse is sampled by an FPGA and sent with 20 MB/s to a PC for preprocessing. The pulse provides information about the gamma energy and the scintillator material which identifies the interaction layer. Furthermore, the exact pulse starting time is obtained from the sampled data. This is important as no hardware coincidence detection is implemented. All single events are recorded and coincidences are identified by software. The system in Jülich (ClearPET Neuro) is equipped with 10240 crystals on 80 PMTs. The paper will present an overview of the data acquisition system. Y1 - 2006 SN - 0018-9499 VL - 53 IS - 3 SP - 700 EP - 703 ER - TY - JOUR A1 - Khodaverdi, M. A1 - Weber, S. A1 - Streun, M. A1 - Parl, C. A1 - Ziemons, Karl T1 - High resolution imaging with ClearPET™ Neuro - first animal images JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 3 N2 - The ClearPET™ Neuro is the first full ring scanner within the Crystal Clear Collaboration (CCC). It consists of 80 detector modules allocated to 20 cassettes. LSO and LuYAP:Ce crystals in phoswich configuration in combination with position sensitive photomultiplier tubes are used to achieve high sensitivity and realize the acquisition of the depth of interaction (DOI) information. The complete system has been tested concerning the mechanical and electronical stability and interplay. Moreover, suitable corrections have been implemented into the reconstruction procedure to ensure high image quality. We present first results which show the successful operation of the ClearPET™ Neuro for artefact free and high resolution small animal imaging. Based on these results during the past few months the ClearPET™ Neuro System has been modified in order to optimize the performance. Y1 - 2006 SN - 1082-3654 SP - 1641 EP - 1644 ER - TY - JOUR A1 - Streun, M. A1 - Brandenburg, G. A1 - Khodaverdi, M. A1 - Larue, H. A1 - Parl, C. A1 - Ziemons, Karl T1 - Timemark correction for the ClearPET™ scanners JF - 2005 IEEE Nuclear Science Symposium Conference Record, Vol. 4 N2 - The small animal PET scanners developed by the Crystal Clear Collaboration (ClearPETtrade) detect coincidences by analyzing timemarks which are attached to each event. The scanners are able to save complete single list mode data which allows analysis and modification of the timemarks after data acquisition. The timemarks are obtained from the digitally sampled detector pulses by calculating the baseline crossing of the rising edge of the pulse which is approximated as a straight line. But the limited sampling frequency causes a systematic error in the determination of the timemark. This error depends on the phase of the sampling clock at the time of the event. A statistical method that corrects these errors will be presented Y1 - 2006 SN - 1082-3654 SP - 2057 EP - 2060 ER - TY - JOUR A1 - Jens, Otto A1 - Kaldenhoff, E. A1 - Kirschner-Hermanns, R. A1 - Mühl, Thomas A1 - Klinge, Uwe T1 - Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates JF - Journal of biomedical materials research. Part A N2 - Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome. Y1 - 2014 U6 - https://doi.org/10.1002/jbm.a.34767 SN - 1552-4965 VL - 102 IS - 4 SP - 1079 EP - 1084 PB - Wiley CY - New York ER - TY - JOUR A1 - Miyamoto, Ko-ichiro A1 - Ichimura, Hiroki A1 - Wagner, Torsten A1 - Schöning, Michael Josef A1 - Yoshinobu, Tatsuo T1 - Chemical imaging of the concentration profile of ion diffusion in a microfluidic channel JF - Sensors and actuators. B: Chemical N2 - The chemical imaging sensor is a device to visualize the spatial distribution of chemical species based on the principle of LAPS (light-addressable potentiometric sensor), which is a field-effect chemical sensor based on semiconductor. In this study, the chemical imaging sensor has been applied to investigate the ion profile of laminar flows in a microfluidic channel. The chemical images (pH maps) were collected in a Y-shaped microfluidic channel while injecting HCl and NaCl solutions into two branches. From the chemical images, it was clearly observed that the injected solutions formed laminar flows in the channel. In addition, ion diffusion across the laminar flows was observed, and the diffusion coefficient could be derived by fitting the pH profiles to the Fick's equation. Y1 - 2013 U6 - https://doi.org/10.1016/j.snb.2013.04.057 SN - 1873-3077 (E-Journal); 0925-4005 (Print) N1 - Part of special issue "Selected Papers from the 26th European Conference on Solid-State Transducers" VL - 189 SP - 240 EP - 245 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Bohrn, Ulrich A1 - Mucha, Andreas A1 - Werner, Frederik A1 - Trattner, Barbara A1 - Bäcker, Matthias A1 - Krumbe, Christoph A1 - Schienle, Meinrad A1 - Stütz, Evamaria A1 - Schmitt-Landsiedel, Doris A1 - Fleischer, Maximilian A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - A critical comparison of cell-based sensor systems for the detection of Cr (VI) in aquatic environment JF - Sensors and actuators. B: Chemical Y1 - 2013 SN - 1873-3077 (E-Journal); 0925-4005 (Print) VL - Vol. 182 SP - 58 EP - 65 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Meliß, Michael A1 - Neskakis, A. A1 - Plettner-Marliani, J. A1 - Lange, C. A1 - Hövelmann, A. A1 - Schumacher, J. T1 - Waste water recycling supplied by renewable energies : basic conditions and possible treatment technologies JF - Renewable energy. Vol. 14 (1998), iss. 1-4. 6th Arab International Solar Energy Conference: Bringing Solar Energy into the Daylight, Muscat, Sultanate of Oman, 29.03.-01.04.1998 Y1 - 1998 SN - 1879-0682 (E-Book); 0960-1481 (Print) SP - 325 EP - 331 ER - TY - JOUR A1 - Wemhöner, Carsten A1 - Hafner, Bernd A1 - Schwarzer, Klemens T1 - Simulation of solar thermal systems with CARNOT blockset in the environment MATLAB-Simulink Y1 - 2000 SP - 1 EP - 6 ER - TY - JOUR A1 - Vitusevich, S. A. A1 - Förster, Arnold A1 - Lüth, H. A1 - Belyaev, A. E. A1 - Danylyuk, S. V. A1 - Konakova, R. V. A1 - Sheka, D. I. T1 - Resonant spectroscopy of electric-field-induced superlattices JF - Journal of Applied Physics. 90 (2001), H. 6 Y1 - 2001 SN - 1089-7550 U6 - https://doi.org/10.1063/1.1392956 SP - 2857 EP - 2861 ER - TY - JOUR A1 - Stock, J. A1 - Malindretos, J. A1 - Indlekofer, K.M. A1 - Pöttgens, Michael A1 - Förster, Arnold A1 - Lüth, Hans T1 - A Vertical Resonant Tunneling Transistor for Application in Digital Logic Circuits JF - IEEE Transactions on Electron Devices (T-ED). 48 (2001), H. 6 Y1 - 2001 SN - 0018-9383 SP - 1028 EP - 1032 ER - TY - JOUR A1 - Schwarzer, Klemens A1 - Schlenger, Barbara J. T1 - Investigation of fission product aerosol behavior in an HTR containment during severe core-heatup accidents / Barbara J. Schlenger ; K. Schwarzer JF - Tagungsbericht : Maritim Kongresszentrum, 17. - 19. Mai '88 Travemünde / Kerntechnische Gesellschaft e.V.; Deutsches Atomforum e.V. [Red.: K. G. Bauer] Y1 - 1988 SN - 0720-9207 N1 - Jahrestagung Kerntechnik <1988, Lübeck-Travemünde> ; Annual Meeting of Nuclear Technology <1988, Lübeck-Travemünde> SP - 179 EP - 182 PB - Inforum CY - Bonn ER - TY - JOUR A1 - Hodel, U. A1 - Orzati, A. A1 - Marso, M. A1 - Homann, O. A1 - Fox, A. A1 - Hart, A. v. d. A1 - Förster, Arnold A1 - Kordos, P. A1 - Lüth, H. T1 - A novel InAlAs/InGaAs layer structure for monolithically integrated photoreceiver JF - Conference Proceedings: 2000 International Conference on Indium Phosphide and related materials Y1 - 2000 SN - 0-7803-6320-5 N1 - International Conference on Indium Phosphide and Related Materials <12, 2000, Williamsburg, Va.> SP - 466 EP - 469 PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Hoskens, R.C.P. A1 - Roer, T.G. van de A1 - Tolstikhin, V.I. A1 - Förster, Arnold T1 - Hot electron injection laser: vertically integrated transistor-laser structure for high-speed, low-chirp direct modulation JF - LEOS 2000 : 2000 IEEE annual meeting conference proceedings; 13th annual meeting; IEEE Lasers and Electro-Optics Society 2000 annual meeting; 13-16 November 2000, The Westin Rio Mar Beach, Rio Grande, Puerto Rico. Vol. 2 Y1 - 2000 SN - 0-7803-5947-X N1 - 2000 IEEE LEOS annual meeting SP - 444 EP - 445 PB - IEEE Service Center CY - Piscataway, NJ ER - TY - JOUR A1 - Hoskens, R. C. P. A1 - Tolstikhin, V.I. A1 - Förster, Arnold A1 - Roer, T.G. van de T1 - Vertically integrated transistor-laser structure, take 2 JF - WOCSDICE 2000, 24th Workshop on Compound Semiconductor Devices and Integrated Circuits held in Europe : May 29 - June 02, 2000, Aegean Sea, Greece. Y1 - 2000 SN - 0970311109 N1 - WOCSDICE ; (24, 2000) Workshop on Compound Semiconductor Devices and Integrated Circuits held in Europe ; (24 : ; 2000.05.29-06.02) PB - Univ. of Michigan CY - Ann Arbor, Mich. ER - TY - JOUR A1 - Darmo, J. A1 - Schäffer, F. A1 - Förster, Arnold A1 - Kordos, P. T1 - Beryllium doped low-temperature-grown MBE GaAs: material for photomixing in the THz frequency range JF - ASDAM 2000 : conference proceedings / edited by Jozef Osvald ... [et al.] Y1 - 2000 SN - 0780359399 N1 - International Conference on Advanced Semiconductor Devices and Microsystems ; (3rd : ; 2000 : ; Smolenice, Slovakia) SP - 147 EP - 150 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Griebel, M. A1 - Indlekofer, K.M. A1 - Lüth, H. T1 - Single electron transport in resonant tunnelling diodes laterally confined by ion implantation. Griebel, M.; Indlekofer, K.M.; Förster, A.; Lüth, H. JF - Journal of Physics D: Applied Physics. 32 (1999), H. 14 Y1 - 1999 SN - 1361-6463 SP - 1729 EP - 1733 ER - TY - JOUR A1 - Schmidt, R. A1 - Tonnesmann, A. A1 - Förster, Arnold A1 - Grimm, M. A1 - Kordos, P. A1 - Lüth, H. T1 - Metamorphic InAlAs/InGaAs HEMT's on GaAs substrates using an InP buffer layer JF - 8th IEEE International Symposium on High Performance Electron Devices for Microwave and Optoelectronic Applications : EDMO 2000 ; [13 - 14 November 2000, University of Glasgow] / organised by Department of Electronics and Electrical Engineering, University of Glasgow, Glasgow Scotland. MTT/ED/AP/LEO Societies Joint Chapter, United Kingdom and Republic of Ireland Section. With technical co-sponsorship from IEEE Electron Device Society Y1 - 2000 SN - 0-7803-6550-X N1 - EDMO <8, 2000, Glasgow> ; University / Department of Electronics and Electrical Engineering ; IEEE catalog number 00TH8534 SP - 95 EP - 98 PB - IEEE Operations Center CY - Piscataway, NJ ER - TY - JOUR A1 - Förster, Arnold A1 - Betko, J. A1 - Morvic, M. A1 - Novak, J. T1 - Magnetoresistance in low-temperature grown molecular-beam epitaxial GaAs. Betko, J.; Morvic, M.; Novak, J.; Förster, A.; Kordos, P. JF - Journal of Applied Physics. 86 (1999), H. 11 Y1 - 1999 SN - 1089-7550 SP - 6243 EP - 6248 ER -