TY - JOUR A1 - Kowalewski, Paul A1 - Bragard, Michael A1 - Hüning, Felix A1 - De Doncker, Rik W. T1 - An inexpensive Wiegand-sensor-based rotary encoder without rotating magnets for use in electrical drives JF - IEEE Transactions on Instrumentation and Measurement N2 - This paper introduces an inexpensive Wiegand-sensor-based rotary encoder that avoids rotating magnets and is suitable for electrical-drive applications. So far, Wiegand-sensor-based encoders usually include a magnetic pole wheel with rotating permanent magnets. These encoders combine the disadvantages of an increased magnet demand and a limited maximal speed due to the centripetal force acting on the rotating magnets. The proposed approach reduces the total demand of permanent magnets drastically. Moreover, the rotating part is manufacturable from a single piece of steel, which makes it very robust and cheap. This work presents the theoretical operating principle of the proposed approach and validates its benefits on a hardware prototype. The presented proof-of-concept prototype achieves a mechanical resolution of 4.5 ° by using only 4 permanent magnets, 2Wiegand sensors and a rotating steel gear wheel with 20 teeth. KW - Rotary encoder KW - Wiegand sensor Y1 - 2023 U6 - https://doi.org/10.1109/TIM.2023.3326166 SN - 0018-9456 (Print) SN - 1557-9662 (Online) VL - 72 SP - 10 Seiten PB - IEEE CY - New York ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Breyer, Tobias A1 - Kruszona, Stefan A1 - Maderwald, Stefan A1 - Brote, Irina A1 - Gizewski, Elke R. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - A transmit/receive radiofrequency array for imaging the carotid arteries at 7 Tesla: coil design and first in vivo results JF - Investigative Radiology N2 - Objective: To develop a transmit/receive radiofrequency (RF) array for magnetic resonance imaging (MRI) of the carotid arteries at 7 T. The prototype is characterized in numerical simulations and bench measurements, and the feasibility of plaque imaging at 7 T is demonstrated in first in vivo images. Materials and Methods: The RF phased array coil consists of 8 surface loop coils. To allow imaging of both sides of the neck, the RF array is divided into 2 coil clusters, each with 4 overlapping loop elements. For safety validation, numerical computations of the RF field distribution and the corresponding specific absorption rate were performed on the basis of a heterogeneous human body model. To validate the coil model, maps of the transmit B1+ field were compared between simulation and measurement. In vivo images of a healthy volunteer and a patient (ulcerating plaque and a 50% stenosis of the right internal carotid artery) were acquired using a 3-dimensional FLASH sequence with a high isotropic spatial resolution of 0.54 mm as well as using pulse-triggered proton density (PD)/T2-weighted turbo spin echo sequences. Results: Measurements of the S-parameters yielded a reflection and isolation of the coil elements of better than −18 and −13 dB, respectively. Measurements of the g-factor indicated good image quality for parallel imaging acceleration factors up to 2.4. A similar distribution and a very good match of the absolute values were found between the measured and simulated B1+ transmit RF field for the validation of the coil model. In vivo images revealed good signal excitation of both sides of the neck and a high vessel-to-background image contrast for the noncontrast-enhanced 3-dimensional FLASH sequence. Imaging at 7 T could depict the extent of stenosis, and revealed the disruption and ulcer of the plaque. Conclusions: This study demonstrates that 2 four-channel transmit/receive RF arrays for each side of the neck is a suitable concept for in vivo MRI of the carotid arteries at 7 Tesla. Further studies are needed to explore and exploit the full potential of 7 T high-field MRI for carotid atherosclerotic plaque imaging. Y1 - 2011 U6 - https://doi.org/10.1097/RLI.0b013e318206cee4 SN - 1536-0210 VL - 46 IS - 4 SP - 246 EP - 254 PB - Wolters Kluwer CY - Köln ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Dammann, Philipp A1 - Ladd, Susanne C. A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel transmit/receive multipurpose coil for musculoskeletal MR imaging at 7 T JF - Medical Physics N2 - Purpose: MRI plays a leading diagnostic role in assessing the musculoskeletal (MSK) system and is well established for most questions at clinically used field strengths (up to 3 T). However, there are still limitations in imaging early stages of cartilage degeneration, very fine tendons and ligaments, or in locating nerve lesions, for example. 7 T MRI of the knee has already received increasing attention in the current published literature, but there is a strong need to develop new radiofrequency (RF) coils to assess more regions of the MSK system. In this work, an eight-channel transmit/receive RF array was built as a multipurpose coil for imaging some of the thus far neglected regions. An extensive coil characterization protocol and first in vivo results of the human wrist, shoulder, elbow, knee, and ankle imaged at 7 T will be presented. Methods: Eight surface loop coils with a dimension ofurn:x-wiley:00942405:media:mp7176:mp7176-math-0001 were machined from FR4 circuit board material. To facilitate easy positioning, two coil clusters, each with four loop elements, were combined to one RF transmit/receive array. An overlapped and shifted arrangement of the coil elements was chosen to reduce the mutual inductance between neighboring coils. A phantom made of body-simulating liquid was used for tuning and matching on the bench. Afterward, the S-parameters were verified on a human wrist, elbow, and shoulder. For safety validation, a detailed compliance test was performed including full wave simulations of the RF field distribution and the corresponding specific absorption rate (SAR) for all joints. In vivo images of four volunteers were assessed with gradient echo and spin echo sequences modified to obtain optimal image contrast, full anatomic coverage, and the highest spatial resolution within a reasonable acquisition time. The performance of the RF coil was additionally evaluated by in vivo B1 mapping. Results: A comparison of B1 per unit power, flip angle distribution, and anatomic images showed a fairly homogeneous excitation for the smaller joints (elbow, wrist, and ankle), while for the larger joints, the shoulder and especially the knee, B1 inhomogeneities and limited penetration depth were more pronounced. However, the greater part of the shoulder joint could be imaged.In vivo images rendered very fine anatomic details such as fascicles of the median nerve and the branching of the nerve bundles. High-resolution images of cartilage, labrum, and tendons could be acquired. Additionally, turbo spin echo (TSE) and inversion recovery sequences performed very well. Conclusions: This study demonstrates that the concept of two four-channel transmit/receive RF arrays can be used as a multipurpose coil for high-resolutionin vivo MR imaging of the musculoskeletal system at 7 T. Not only gradient echo but also typical clinical and SAR-intensive sequences such as STIR and TSE performed well. Imaging of small structures and peripheral nerves could in particular benefit from this technique. Y1 - 2010 U6 - https://doi.org/10.1118/1.3517176 SN - 2473-4209 VL - 37 IS - 12 SP - 6368 EP - 6376 PB - Wiley CY - Hoboken, NJ ER - TY - JOUR A1 - Kraff, Oliver A1 - Bitz, Andreas A1 - Kruszona, Stefan A1 - Orzada, Stephan A1 - Schaefer, Lena C. A1 - Theysohn, Jens M. A1 - Maderwald, Stefan A1 - Ladd, Mark E. A1 - Quick, Harald H. T1 - An eight-channel phased array RF coil for spine MR imaging at 7 T JF - Investigative Radiology Y1 - 2009 U6 - https://doi.org/10.1097/RLI.0b013e3181b24ab7 SN - 1536-0210 VL - 44 IS - 11 SP - 734 EP - 740 PB - Lippincott Williams & Wilkins ER - TY - JOUR A1 - Kraff, Oliver A1 - Wrede, Karsten H. A1 - Schoemberg, Tobias A1 - Dammann, Philipp A1 - Noureddine, Yacine A1 - Orzada, Stephan A1 - Ladd, Mark E. A1 - Bitz, Andreas T1 - MR safety assessment of potential RF heating from cranial fixation plates at 7 T JF - Medical Physics Y1 - 2013 U6 - https://doi.org/10.1118/1.4795347 SN - 2473-4209 VL - 40 IS - 4 SP - 042302-1 EP - 042302-10 PB - Wiley CY - Hoboken ER - TY - JOUR A1 - Krause, Gregor T1 - High Field Phenomena of Polymeric Insulation Investigated at PE Needle-Plane Specimen JF - Seventh International Symposium on High Voltage Engineering : Dresden, August 26 - 30, 1991 / Technische Universität Dresden Y1 - 1991 N1 - International Symposium on High Voltage Engineering ; (7, 1991, Dresden); International Symposium on High Voltage Engineering (ISH) ; (7 : ; 1991.08.26-30 : ; Dresden) PB - TU Dresden CY - Dresden ER - TY - JOUR A1 - Krause, Gregor A1 - Fruth, B. T1 - Dielectric Properties of Polyolefins Stressed by High Electrical Fields / Fruth, B. ; Krause, G. JF - Plenary lectures and contributions presented at the International Symposium on Polymer Materials : held in San Sebastian (Donostia), Spain, 31 August - 4 September, 1987 / symposium ed. G. M. Guzmán ; A. Santamaria Y1 - 1988 SN - 3-85739-220-7 N1 - International Symposium on Polymer Materials <1987, San Sebastián, Golfo de Vizcaya> PB - Huethig & Wepf CY - Basel ER - TY - JOUR A1 - Krause, Gregor A1 - Fruth, Bernhard T1 - Dielectric Properties of Polyolefins Stressed by High Electrical Fields. Fruth, B. ; Krause, G. Y1 - 1987 N1 - Fifth International Symposium on High Voltage Engineering : Proceedings; Braunschweig, Stadthalle, August, 24-28, 1987 / International Symposium on High Voltage Engineering <5, 1987, Braunschweig> ER - TY - JOUR A1 - Krause, Gregor A1 - Göttlich, S. A1 - Möller, K. A1 - Meurer, D. T1 - Space Charge Phenomena in Partially Crystalline Polymers: On-Line Measurement of Charge Carrier Motion under High AC-Field Strength / G. Krause, S. Göttlich, K. Möller, D. Meurer JF - Proceedings of the 3rd International Conference on Conduction and Breakdown in Solid Dielectrics : Trondheim, Norway ... 1989 Y1 - 1989 N1 - International Conference on Conduction and Breakdown in Solid Dielectrics <3, 1989, Trondheim> PB - IEEE CY - Piscataway, N.J. ER - TY - JOUR A1 - Krause, Gregor A1 - Meurer, D. A1 - Klee, D. T1 - Space Charge Formation Related to the Morphology of Polymers JF - ISE 6 : 6th International symposium on electrets : Papers Y1 - 1988 N1 - International Symposium on Electrets <6, 1988, Oxford> PB - IEEE CY - Piscataway, NY ER - TY - JOUR A1 - Krause, Gregor A1 - Meurer, D. A1 - Klee, D. T1 - Space charge formation related to the morphology of polymers JF - IEEE Transaction on Electrical Insulation. Vol. 24 (1989), H. No. 3 Y1 - 1989 N1 - Digital Object Identifier 10.1109/14.30883 SP - 215 EP - 222 ER - TY - JOUR A1 - Krause, Gregor A1 - Möller, K. A1 - Meurer, D. T1 - Dielectric phenomena in semicrystalline polymers JF - IEEE Transaction on Electrical Insulation. Vol. 24 (1989), H. No. 2 Y1 - 1989 N1 - Digital Object Identifier 10.1109/14.90276 SP - 215 EP - 222 ER - TY - JOUR A1 - Krause, Gregor A1 - Neubert, R. A1 - Pietsch, R. T1 - Investigations of Electrical Aging in Polymers under High AC-Field Strength JF - 1990 annual report : October 28 - October 31, 1990 / sponsored by the IEEE Dielectrics and Electrical Insulation Society Y1 - 1990 N1 - Conference on Electrical Insulation and Dielectric Phenomena ; (59, 1990, Pocono Manor, Pa.) PB - IEEE Service Center CY - Piscataway, N.J ER - TY - JOUR A1 - Krause, Gregor A1 - Rodriguez, Jackson A1 - Stopic, Srecko A1 - Friedrich, Bernd T1 - Feasibility assessment of electrocoagulation towards a new sustainable wastewater treatment / Rodriguez, Jackson ; Stopic, Srecko ; Krause Gregor ; Friedrich, Bernd JF - Environmental Science and Pollution Research. 14 (2007), H. 7 Y1 - 2007 SN - 0944-1344 SP - 477 EP - 482 ER - TY - JOUR A1 - Krause, Gregor A1 - Schuppe, W.D. A1 - Saure, M. A1 - Andress, H. T1 - Sensitive Analytical and Physical Methods for Diagnosis of Variations in Polyolefin Plaques and Cable Insulations / W.D. Schuppe, M. Saure, H. Andress, K. Möller, D. Meurer, G. Krause JF - Proceedings of the 32nd session : 28th August - 3rd September. Y1 - 1988 N1 - International Conference on Large Electric Systems, CIGRÉ <32, Paris, 1988> ER - TY - JOUR A1 - Köhler, Klemens T1 - A conflict theory perspective of IT attacks – consequences for IT security education N2 - Cyberspace is "the environment formed by physical and non-physical components to store, modify, and exchange data using computer networks" (NATO CCDCOE). Beyond that, it is an environment where people interact. IT attacks are hostile, non-cooperative interactions that can be described with conflict theory. Applying conflict theory to IT security leads to different objectives for end-user education, requiring different formats like agency-based competence developing games. Y1 - 2020 IS - Preprint ER - TY - JOUR A1 - Köhler, Klemens A1 - Röpke, René A1 - Wolf, Martin R. T1 - Through a mirror darkly – On the obscurity of teaching goals in game-based learning in IT security JF - ISAGA 2019: Simulation Gaming Through Times and Disciplines N2 - Teachers and instructors use very specific language communicating teaching goals. The most widely used frameworks of common reference are the Bloom’s Taxonomy and the Revised Bloom’s Taxonomy. The latter provides distinction of 209 different teaching goals which are connected to methods. In Competence Developing Games (CDGs - serious games to convey knowledge) and in IT security education, a two- or three level typology exists, reducing possible learning outcomes to awareness, training, and education. This study explores whether this much simpler framework succeeds in achieving the same range of learning outcomes. Method wise a keyword analysis was conducted. The results were threefold: 1. The words used to describe teaching goals in CDGs on IT security education do not reflect the whole range of learning outcomes. 2. The word choice is nevertheless different from common language, indicating an intentional use of language. 3. IT security CDGs use different sets of terms to describe learning outcomes, depending on whether they are awareness, training, or education games. The interpretation of the findings is that the reduction to just three types of CDGs reduces the capacity to communicate and think about learning outcomes and consequently reduces the outcomes that are intentionally achieved. KW - IT security education KW - Competence Developing Games KW - Game-based learning KW - Keyword analysis KW - Bloom’s Taxonomy Y1 - 2021 U6 - https://doi.org/10.1007/978-3-030-72132-9_6 N1 - ISAGA 2019 - International Simulation and Gaming Association Conference. 26-30 August 2019. Warsaw, Poland. Part of the Lecture Notes in Computer Science book series (LNCS, volume 11988) SP - 61 EP - 73 PB - Springer CY - Cham ER - TY - JOUR A1 - Köllensperger, P. A1 - Bragard, Michael A1 - Plum, T. A1 - De Doncker, R. W. T1 - The dual GCT : new high-power device using optimized GCT technology JF - IEEE transactions on industry applications Y1 - 2009 U6 - https://doi.org/10.1109/TIA.2009.2027364 SN - 0093-9994 VL - 45 IS - 5 SP - 1754 EP - 1762 ER - TY - JOUR A1 - König, Johannes Alexander A1 - Wolf, Martin R. T1 - GHOST: An Evaluated Competence Developing Game for Cybersecurity Awareness Training JF - International Journal on Advances in Security N2 - To train end users how to interact with digital systems is indispensable to ensure a strong computer security. 'Competence Developing Game'-based approaches are particularly suitable for this purpose because of their motivation-and simulation-aspects. In this paper the Competence Developing Game 'GHOST' for cybersecurity awareness trainings and its underlying patterns are described. Accordingly, requirements for an 'Competence Developing Game' based training are discussed. Based on these requirements it is shown how a game can fulfill these requirements. A supplementary game interaction design and a corresponding evaluation study is shown. The combination of training requirements and interaction design is used to create a 'Competence Developing Game'-based training concept. A part of these concept is implemented into a playable prototype that serves around one hour of play respectively training time. This prototype is used to perform an evaluation of the game and training aspects of the awareness training. Thereby, the quality of the game aspect and the effectiveness of the training aspect are shown. Y1 - 2018 SN - 1942-2636 VL - 11 IS - 3 & 4 SP - 274 EP - 287 PB - IARIA Journals ER - TY - JOUR A1 - Lagemaat, Miriam W. A1 - Breukels, Vincent A1 - Vos, Eline K. A1 - Kerr, Adam B. A1 - Uden, Mark J. van A1 - Orzada, Stephan A1 - Bitz, Andreas A1 - Maas, Marnix C. A1 - Scheenen, Tom W. J. T1 - ¹H MR spectroscopic imaging of the prostate at 7T using spectral-spatial pulses JF - Magnetic Resonance in Medicine N2 - Purpose To assess the feasibility of prostate ¹H MR spectroscopic imaging (MRSI) using low-power spectral-spatial (SPSP) pulses at 7T, exploiting accurate spectral selection and spatial selectivity simultaneously. Methods A double spin-echo sequence was equipped with SPSP refocusing pulses with a spectral selectivity of 1 ppm. Three-dimensional prostate ¹H-MRSI at 7T was performed with the SPSP-MRSI sequence using an 8-channel transmit array coil and an endorectal receive coil in three patients with prostate cancer and in one healthy subject. No additional water or lipid suppression pulses were used. Results Prostate ¹H-MRSI could be obtained well within specific absorption rate (SAR) limits in a clinically feasible time (10 min). Next to the common citrate signals, the prostate spectra exhibited high spermine signals concealing creatine and sometimes also choline. Residual lipid signals were observed at the edges of the prostate because of limitations in spectral and spatial selectivity. Conclusion It is possible to perform prostate ¹H-MRSI at 7T with a SPSP-MRSI sequence while using separate transmit and receive coils. This low-SAR MRSI concept provides the opportunity to increase spatial resolution of MRSI within reasonable scan times. Y1 - 2016 U6 - https://doi.org/10.1002/mrm.25569 SN - 1522-2594 VL - 75 IS - 3 SP - 933 EP - 945 PB - International Society for Magnetic Resonance in Medicine ER -