TY - JOUR A1 - Hardt, Arno A1 - Bisplinghoff, J. A1 - Ernst, J. A1 - Löhr, R. T1 - On-line apparatus BANDIT for half-life determination of short-lived neutron deficient isotopes. A. Hardt, J. Bisplinghoff, J. Ernst, R. Löhr, H. Machner, T . Mayer-Kuckuk JF - Nuclear Instruments and Methods. 143 (1977), H. 3 Y1 - 1977 SN - 0029-554X SP - 519 EP - 523 ER - TY - JOUR A1 - Hardt, Arno A1 - Köhler, M. A1 - Müller, K. D. A1 - Stoff, H. T1 - A two-dimensional position sensitive charged-particle detector for the magnetic spectrograph "BIG KARL" of the Jülich Cyclotron "JULIC". M. Köhler, K. D. Müller, H. Stoff, M. Teske, G. P. A. Berg, A. Hardt, S. Martin, C. Mayer-Böricke , J. Meißburger JF - Nuclear Instruments and Methods. 75 (1980), H. 2-3 Y1 - 1980 SN - 0029-554X SP - 357 EP - 362 ER - TY - JOUR A1 - Hardt, Arno A1 - Martin, S. A1 - Meißburger, J. A1 - Retz, R. A1 - Wimmer, J. T1 - The cryopump system of the QQDDQ magnet spectrometer BIG KARL JF - Vacuum N2 - Cryopumps without liquid nitrogen shielding are used to provide a vacuum of 10−6 torr in the spectrometer. The vacuum system is subdivided in three sections that can be separated by valves. The first section (scattering chamber) has a volume of 60 l, two rotation transmissions with 35 cm dia and a sliding seal that allows a rotation of 160° without deteriorating the vacuum. The second section includes the vacuum chambers inside the magnets with 6 × 80 cm cross-section and a length of 1200 cm. The third section (detector box) has a volume of 4300 l and contains a moveable detector system. The gas inside the detector with a pressure of 760 torr is separated from the vacuum by a 15 μm mylar foil with an area of 300 cm2. The detector box can be valved off by a valve with the dimension of 10 × 100 cm. The layout of system is given. The instrumentation and the interlock system are described. First experiences with this system are presented. Y1 - 1978 U6 - http://dx.doi.org/10.1016/S0042-207X(78)80026-8 SN - 1879-2715 (E-Journal); 0042-207X (Print) VL - 28 IS - 10-11 SP - 483 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Hartung, I. A1 - Dilger, Klaus A1 - Hellmanns, Mark A1 - Böhme, Stefan T1 - Repair of non-weldable steel structures to extend the life cycle T2 - Proceedings of the IIW International Conference on Advances in Welding and Allied Technologies : July 16 - 17, 2009, Singapore. (Welding in the world ; 53.2009, special issue) Y1 - 2009 SN - 978-981-08-3259-9 SP - 569 EP - 574 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Heel, Mareike van A1 - Dikta, Gerhard A1 - Braekers, Roel T1 - Bootstrap based goodness‑of‑fit tests for binary multivariate regression models JF - Journal of the Korean Statistical Society N2 - We consider a binary multivariate regression model where the conditional expectation of a binary variable given a higher-dimensional input variable belongs to a parametric family. Based on this, we introduce a model-based bootstrap (MBB) for higher-dimensional input variables. This test can be used to check whether a sequence of independent and identically distributed observations belongs to such a parametric family. The approach is based on the empirical residual process introduced by Stute (Ann Statist 25:613–641, 1997). In contrast to Stute and Zhu’s approach (2002) Stute & Zhu (Scandinavian J Statist 29:535–545, 2002), a transformation is not required. Thus, any problems associated with non-parametric regression estimation are avoided. As a result, the MBB method is much easier for users to implement. To illustrate the power of the MBB based tests, a small simulation study is performed. Compared to the approach of Stute & Zhu (Scandinavian J Statist 29:535–545, 2002), the simulations indicate a slightly improved power of the MBB based method. Finally, both methods are applied to a real data set. Y1 - 2021 U6 - http://dx.doi.org/10.1007/s42952-021-00142-4 SN - 2005-2863 (Online) SN - 1226-3192 (Print) N1 - Corresponding author: Mareike van Heel VL - 51 PB - Springer Nature CY - Singapur ER - TY - CHAP A1 - Hellmanns, Mark A1 - Böhm, Stefan A1 - Dilger, Klaus T1 - Weight and noise reduction in power transmissions through epoxy resin foams T2 - Proceedings of the 31st annual meeting of the Adhesion Society : 17. - 20.2.2008, Austin, Texas Y1 - 2008 SP - 291 EP - 293 PB - Adhesion Society CY - Blacksburg ER - TY - CHAP A1 - Hellmanns, Mark A1 - Böhm, Stefan A1 - Dilger, Klaus T1 - Implementation of a velocity controlled manual applicator for adhesives and sealants in the automotive industry in consideration of quality control T2 - Proceedings of the 29th annual meeting of the Adhesion Society : 19. - 22.2.2006, Jacksonville, Florida Y1 - 2006 SN - 1086-9506 SP - 68 EP - 70 PB - Adhesion Society CY - Blacksburg, Va. ER - TY - JOUR A1 - Hellmanns, Mark A1 - Böhm, Stefan A1 - Dilger, Klaus T1 - Manual applications of adhesives JF - Journal of adhesion and interface Y1 - 2006 VL - Vol. 7 IS - No. 4 SP - 24 EP - 27 ER - TY - CHAP A1 - Hellmanns, Mark A1 - Böhm, Stefan A1 - Dilger, Klaus T1 - Progress of the manual application of adhesives T2 - Proceedings of the 3rd World Congress on Adhesion and Related Phenomena : WCARP-III, October 15 -18, 2006, Beijing, China Y1 - 2006 SP - 275 EP - 277 PB - Beijing Adhesion Society of China CY - Beijing ER - TY - CHAP A1 - Hellmanns, Mark A1 - Hartung, I. A1 - Dilger, Klaus A1 - Böhm, Stefan T1 - Quality assurance of manual guided joining and welding devices T2 - Proceedings of the IIW International Conference on Advances in Welding and Allied Technologies : July 16 - 17, 2009, Singapore Y1 - 2009 SN - 9789810832605 SP - 219 EP - 222 PB - International Institute of Welding CY - Roissy ER - TY - JOUR A1 - Helsper, Christoph T1 - Evaluation of Particle Size Distributions by Means of Particle Counters / Fißan, H. J. ; Helsper, C. JF - Proceedings of the First Workshop of Particulate Control : 16. - 17. March 1978, Kernforschung-sanlage Jülich GmbH / prepared by U.S. Environmental Protection Agency, Off. of Research and Development, Washington, D.C, 1979, Y1 - 1979 N1 - Workshop of Particulate Control ; (1, 1978, Jülich); Berichte der Kernforschungsanlage Jülich Conferences ; 28 PB - Zentralbibliothek d. Kernforschungsanlage Jülich [in Komm.] CY - Jülich ER - TY - JOUR A1 - Helsper, Christoph T1 - Measurement Techniques For Ultrafine Particles JF - Ultrafine aerosols. Properties and behaviour. Proceedings of the 1. International Workshop on Ultrafine Aerosols of the Sonderforschungsbereich 209 'Stoff- und Energietransport in Aerosolen' -'Mass and energy transfer in aerosols'-, held at the Univ. of Duisburg on Sept. 29, 1986 Y1 - 1986 N1 - International Workshop on Ultrafine Aerosols ; (01) CY - Duisburg ER - TY - JOUR A1 - Helsper, Christoph A1 - Bartz, H. A1 - Fißan, H. J. A1 - Kousaka, Y. (u.a.) T1 - Response Characteristics for Four Condensation Nucleus Counters to Particles in the 3 to 50 nm Diameter Range / Bartz, H. ; Fißan, H. J. ; Helsper, C.; Kousaka, Y. ; Okuyama, K. ; Keady, R. Fruin, S. ; McMurry, P. H.; Pui, D. Y. H. ; Stolzenburg, M. R. JF - Journal of Aerosol Science. 16 (1985), H. 5 Y1 - 1985 SN - 0021-8502 SP - 443 EP - 456 ER - TY - JOUR A1 - Helsper, Christoph A1 - Dreiling, V. A1 - Haller, P. A1 - Kaminski, U. T1 - Intercomparison of Eleven Condensation Nucleus Counters / Dreiling, V. ; Haller, P. ; Helsper, C.; Kaminski, U. ; Plomp, A. ; Raes, F. ; Roth, C. ; Schier, J. ; Schürmann, G. JF - Journal of Aerosol Science. 17 (1986), H. 3 Y1 - 1986 SN - 0021-8502 SP - 565 EP - 570 ER - TY - CHAP A1 - Helsper, Christoph A1 - Fissan, H. J. A1 - Franzen, H. ED - Benarie, Michel M. T1 - Particle Size Distributions of Combustion Aerosols T2 - Atmospheric Pollution 1978 : Proceedings of the 13th International Colloquium; 25-28 April 1978; Paris, France; Edited by Michel M. Benarie N2 - It has been observed that carcinogenic polycyclic aromatic hydrocarbons (PAH) are present in the atmosphere. Combustion processes are considered the most important sources for PAH. Among these, the burning of coal produces the highest emission, but in cities with high traffic density and low meteorological exchange activities, vehicle emissions determine the immission situation, especially in narrow streets. For estimating the potential health effects caused by PAH, it is sufficient to characterize the emission of PAH with respect to their physical state, concentrations, and, as far as the particulate phase is concerned, size distribution. The size distribution is important for transport phenomena, inhalation, and deposition in the respiratory tract. These parameters mainly depend on the combustion system, on system operating conditions, on the exhaust system, and on exhaust cooling conditions. At exhaust-gas temperatures in the range of ambient air temperatures, almost the whole emission of PAH is made up of particulate matter. Y1 - 1978 SN - 0-444-41691-9 U6 - http://dx.doi.org/10.1016/S0166-1116(08)71583-8 SP - 263 EP - 266 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. T1 - Numerical Simulation Studies and Data Reduction for Size Classifying Measurement Techniques / Fißan, H. J.; Helsper, C. JF - Aerosols in science, medicine and technology : conference / Gesellschaft für Aerosolforschung 7. 1979. Y1 - 1979 SP - 199 EP - 205 ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. T1 - Numerical Simulation Studies and Data Reduction for Size Classifying Measurement Techniques / Fißan, H. J.; Helsper, C. JF - Advances in Particle Sampling and Measurement: Proceedings, Daytona Beach, EPA 600/9 80 004, 1980 Y1 - 1980 N1 - Advances in Particle Sampling and Measurement ; (1979.10. : ; Daytona Beach/Fla.) PB - National Technical Information Service CY - Springfield, Va. ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. T1 - Response Characteristic of a Polytec HC-15 Optical Particle Counter JF - Aerosols in science, medicine and technology : Physical and chemical properties of aerosols : Association for Aerosol Research: annual conference. 1980 : Gesellschaft für Aerosolforschung: annual conference. 1980 : Aerosols in science, medicine and technology : Physical and chemical properties of aerosols : Associa-tion for Aerosol Research: annual conference. 1980 : Gesellschaft für Aerosolforschung: annual conference. 1980 : Schmallenberg, 22.10.80 - 24.10.80 Y1 - 1981 N1 - Journal of aerosol science. Volume 0012 ; no 003 SP - 287 EP - 292 PB - Pergamon Pr. CY - Oxford ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. T1 - Calibration of the Polytec HC-15 and HC-70 Optical Particle Counters / Fißan, H. J. ; Helsper, C. JF - Aerosols in the mining and industrial work environments, Vol. 3. Instrumentation, Marple, Virgil A. ; Liu, Benjamin Y. Y1 - 1983 N1 - International Symposium on Aerosols in the Mining and Industrial Work Environment ; (1981.11.01-06 : ; Minneapolis/Minn.) SP - 825 EP - 829 PB - Ann Arbor Science CY - Ann Arbor, Mich. ER - TY - JOUR A1 - Helsper, Christoph A1 - Fißan, H. J. A1 - Kapadi, A. A1 - Liu, B. Y. H. T1 - Data Inversion by Simplex Minimization for the Electrical Aerosol Analyzer JF - Aerosol Science and Technology. 1 (1982), H. 1982 Y1 - 1982 SN - 0278-6826 SP - 136 EP - 146 ER -