TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Kerroumi, Iman A1 - Schusser, Sebastian A1 - Bäcker, Matthias A1 - Zander, Willi A1 - Schubert, Jürgen A1 - Buniatyan, Vahe V. A1 - Martirosyan, Norayr W. A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Multiparameter sensor chip with Barium Strontium Titanate as multipurpose material JF - Electroanalysis N2 - It is well known that biochemical and biotechnological processes are strongly dependent and affected by a variety of physico-chemical parameters such as pH value, temperature, pressure and electrolyte conductivity. Therefore, these quantities have to be monitored or controlled in order to guarantee a stable process operation, optimization and high yield. In this work, a sensor chip for the multiparameter detection of three physico-chemical parameters such as electrolyte conductivity, pH and temperature is realized using barium strontium titanate (BST) as multipurpose material. The chip integrates a capacitively coupled four-electrode electrolyte-conductivity sensor, a capacitive field-effect pH sensor and a thin-film Pt-temperature sensor. Due to the multifunctional properties of BST, it is utilized as final outermost coating layer of the processed sensor chip and serves as passivation and protection layer as well as pH-sensitive transducer material at the same time. The results of testing of the individual sensors of the developed multiparameter sensor chip are presented. In addition, a quasi-simultaneous multiparameter characterization of the sensor chip in buffer solutions with different pH value and electrolyte conductivity is performed. To study the sensor behavior and the suitability of BST as multifunctional material under harsh environmental conditions, the sensor chip was exemplarily tested in a biogas digestate. Y1 - 2014 U6 - http://dx.doi.org/10.1002/elan.201400076 SN - 1521-4109 (E-Journal); 1040-0397 (Print) VL - 26 IS - 5 SP - 980 EP - 987 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Huck, Christina A1 - Poghossian, Arshak A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Combined amperometric/field-effect sensor for the detection of dissolved hydrogen JF - Sensors and actuators B: Chemical N2 - Real-time and reliable monitoring of the biogas process is crucial for a stable and efficient operation of biogas production in order to avoid digester breakdowns. The concentration of dissolved hydrogen (H₂) represents one of the key parameters for biogas process control. In this work, a one-chip integrated combined amperometric/field-effect sensor for monitoring the dissolved H₂ concentration has been developed for biogas applications. The combination of two different transducer principles might allow a more accurate and reliable measurement of dissolved H₂ as an early warning indicator of digester failures. The feasibility of the approach has been demonstrated by simultaneous amperometric/field-effect measurements of dissolved H₂ concentrations in electrolyte solutions. Both, the amperometric and the field-effect transducer show a linear response behaviour in the H₂ concentration range from 0.1 to 3% (v/v) with a slope of 198.4 ± 13.7 nA/% (v/v) and 14.9 ± 0.5 mV/% (v/v), respectively. Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.snb.2012.10.050 SN - 0925-4005 N1 - Part of special issue "Selected Papers from the 14th International Meeting on Chemical Sensors" VL - 187 SP - 168 EP - 173 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Huck, Christina A1 - Schiffels, Johannes A1 - Herrera, Cony N. A1 - Schelden, Maximilian A1 - Selmer, Thorsten A1 - Poghossian, Arshak A1 - Baumann, Marcus A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Metabolic responses of Escherichia coli upon glucose pulses captured by a capacitive field-effect sensor JF - Physica Status Solidi (A) N2 - Living cells are complex biological systems transforming metabolites taken up from the surrounding medium. Monitoring the responses of such cells to certain substrate concentrations is a challenging task and offers possibilities to gain insight into the vitality of a community influenced by the growth environment. Cell-based sensors represent a promising platform for monitoring the metabolic activity and thus, the “welfare” of relevant organisms. In the present study, metabolic responses of the model bacterium Escherichia coli in suspension, layered onto a capacitive field-effect structure, were examined to pulses of glucose in the concentration range between 0.05 and 2 mM. It was found that acidification of the surrounding medium takes place immediately after glucose addition and follows Michaelis–Menten kinetic behavior as a function of the glucose concentration. In future, the presented setup can, therefore, be used to study substrate specificities on the enzymatic level and may as well be used to perform investigations of more complex metabolic responses. Conclusions and perspectives highlighting this system are discussed. Y1 - 2013 U6 - http://dx.doi.org/10.1002/pssa.201200900 SN - 0031-8965 VL - 210 IS - 5 SP - 926 EP - 931 PB - Wiley-VCH CY - Weinheim ER - TY - JOUR A1 - Hugenroth, Kristin A1 - Borchardt, Ralf A1 - Ritter, Philine A1 - Groß‑Hardt, Sascha A1 - Meyns, Bart A1 - Verbelen, Tom A1 - Steinseifer, Ulrich A1 - Kaufmann, Tim A. S. A1 - Engelmann, Ulrich M. T1 - Optimizing cerebral perfusion and hemodynamics during cardiopulmonary bypass through cannula design combining in silico, in vitro and in vivo input JF - Scientific Reports N2 - Cardiopulmonary bypass (CPB) is a standard technique for cardiac surgery, but comes with the risk of severe neurological complications (e.g. stroke) caused by embolisms and/or reduced cerebral perfusion. We report on an aortic cannula prototype design (optiCAN) with helical outflow and jet-splitting dispersion tip that could reduce the risk of embolic events and restores cerebral perfusion to 97.5% of physiological flow during CPB in vivo, whereas a commercial curved-tip cannula yields 74.6%. In further in vitro comparison, pressure loss and hemolysis parameters of optiCAN remain unaffected. Results are reproducibly confirmed in silico for an exemplary human aortic anatomy via computational fluid dynamics (CFD) simulations. Based on CFD simulations, we firstly show that optiCAN design improves aortic root washout, which reduces the risk of thromboembolism. Secondly, we identify regions of the aortic intima with increased risk of plaque release by correlating areas of enhanced plaque growth and high wall shear stresses (WSS). From this we propose another easy-to-manufacture cannula design (opti2CAN) that decreases areas burdened by high WSS, while preserving physiological cerebral flow and favorable hemodynamics. With this novel cannula design, we propose a cannulation option to reduce neurological complications and the prevalence of stroke in high-risk patients after CPB. Y1 - 2021 U6 - http://dx.doi.org/10.1038/s41598-021-96397-2 SN - 2045-2322 VL - 11 IS - Art. No. 16800 SP - 1 EP - 12 PB - Springer CY - Berlin ER - TY - JOUR A1 - Hugenroth, Kristin A1 - Neidlin, Michael A1 - Engelmann, Ulrich M. A1 - Kaufmann, Tim A. S. A1 - Steinseifer, Ulrich A1 - Heilmann, Torsten T1 - Tipless Transseptal Cannula Concept Combines Improved Hemodynamic Properties and Risk‐Reduced Placement: an In Silico Proof‐of‐Concept JF - Artificial Organs Y1 - 2021 U6 - http://dx.doi.org/10.1111/aor.13964 SN - 1525-1594 IS - Accepted Article PB - Wiley CY - Weinheim ER - TY - CHAP A1 - Hunker, Jan A1 - Jung, Alexander A1 - Goßmann, Matthias A1 - Linder, Peter A1 - Staat, Manfred ED - Staat, Manfred ED - Erni, Daniel T1 - Development of a tool to analyze the conduction speed in microelectrode array measurements of cardiac tissue T2 - 3rd YRA MedTech Symposium 2019 : May 24 / 2019 / FH Aachen N2 - The discovery of human induced pluripotent stem cells reprogrammed from somatic cells [1] and their ability to differentiate into cardiomyocytes (hiPSC-CMs) has provided a robust platform for drug screening [2]. Drug screenings are essential in the development of new components, particularly for evaluating the potential of drugs to induce life-threatening pro-arrhythmias. Between 1988 and 2009, 14 drugs have been removed from the market for this reason [3]. The microelectrode array (MEA) technique is a robust tool for drug screening as it detects the field potentials (FPs) for the entire cell culture. Furthermore, the propagation of the field potential can be examined on an electrode basis. To analyze MEA measurements in detail, we have developed an open-source tool. Y1 - 2019 SN - 978-3-940402-22-6 U6 - http://dx.doi.org/10.17185/duepublico/48750 SP - 7 EP - 8 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - JOUR A1 - Hunker, Jan L. A1 - Gossmann, Matthias A1 - Raman, Aravind Hariharan A1 - Linder, Peter T1 - Artificial neural networks in cardiac safety assessment: Classification of chemotherapeutic compound effects on hiPSC-derived cardiomyocyte contractility JF - Journal of Pharmacological and Toxicological Methods Y1 - 2021 U6 - http://dx.doi.org/10.1016/j.vascn.2021.107044 SN - 1056-8719 VL - 111 IS - Article number 107044 PB - Elsevier CY - New York ER - TY - JOUR A1 - Hüllenkremer, B. A1 - Glück, O. A1 - Emons, H. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Voltohmmetrie an polykristallinen Goldelektroden JF - Gesellschaft Mess- und Automatisierungstechnik: Sensoren und Meßsysteme 2000 : Tagung Ludwigsburg, 13. und 14. März 2000 / VDI/VDE-Gesellschaft Meß- und Automatisierungstechnik Y1 - 2000 SN - 3-18-091530-7 N1 - VDI-Berichte; 1530 SP - 45 EP - 54 PB - VDI-Verl. CY - Düsseldorf: ER - TY - JOUR A1 - Iken, Heiko A1 - Ahlborn, K. A1 - Gerlach, F. A1 - Vonau, W. A1 - Zander, W. A1 - Schubert, J. A1 - Schöning, Michael Josef T1 - Development of redox glasses and subsequent processing by means of pulsed laser deposition for realizing silicon-based thin-film sensors JF - Electrochimica acta Y1 - 2013 SN - 1873-3859 (E-Journal); 0013-4686 (Print) SP - Available online 30.8.2013 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Iken, Heiko A1 - Bronder, Thomas A1 - Goretzki, Alexander A1 - Kriesel, Jana A1 - Ahlborn, Kristina A1 - Gerlach, Frank A1 - Vonau, Winfried A1 - Zander, Willi A1 - Schubert, Jürgen A1 - Schöning, Michael Josef T1 - Development of a Combined pH- and Redox-Sensitive Bi-Electrode Glass Thin-Film Sensor JF - physica status solidi a : applications and materials sciences Y1 - 2019 U6 - http://dx.doi.org/10.1002/pssa.201900114 SN - 1862-6319 VL - 216 IS - 12 SP - 1 EP - 8 PB - Wiley CY - Weinheim ER - TY - JOUR A1 - Iken, Heiko A1 - Kirsanov, D. A1 - Legin, A. A1 - Schöning, Michael Josef T1 - Novel Thin-Film Polymeric Materials for the Detection of Heavy Metals JF - Procedia Engineering N2 - A variety of transition metals, e.g., copper, zinc, cadmium, lead, etc. are widely used in industry as components for wires, coatings, alloys, batteries, paints and so on. The inevitable presence of transition metals in industrial processes implies the ambition of developing a proper analytical technique for their adequate monitoring. Most of these elements, especially lead and cadmium, are acutely toxic for biological organisms. Quantitative determination of these metals at low activity levels in different environmental and industrial samples is therefore a vital task. A promising approach to achieve an at-side or on-line monitoring on a miniaturized and cost efficient way is the combination of a common potentiometric sensor array with heavy metal-sensitive thin-film materials, like chalcogenide glasses and polymeric materials, respectively. Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.proeng.2012.09.148 SN - 1877-7058 N1 - Part of special issue "26th European Conference on Solid-State Transducers, EUROSENSOR 2012" IS - 47 SP - 322 EP - 325 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Ingebrandt, S. A1 - Han, Y. A1 - Nakamura, F. A1 - Poghossian, Arshak A1 - Schöning, Michael Josef A1 - Offenhäusser, A. T1 - Label-free detection of single nucleotide polymorphisms utilizing the differential transfer function of field-effect transistors JF - Biosensors and Bioelectronics. 22 (2007), H. 12 Y1 - 2007 SN - 0956-5663 SP - 2834 EP - 2840 ER - TY - GEN A1 - Ingebrandt, Sven A1 - Wagner, Patrick A1 - Schöning, Michael Josef T1 - Engineering of functional interfaces / guest eds. Sven Ingebrandt ; Patrick Wagner ; Michael J. Schöning T2 - Physica Status Solidi (A) Y1 - 2013 SN - 1521-396X (E-Journal); 1862-6319 (E-Journal); 0031-8965 (Print); 1862-6300 (Print) VL - Vol. 210 IS - Iss. 5 SP - 845 ER - TY - BOOK A1 - Iomdina, E. N. A1 - Bauer, S. M. A1 - Kotliar, Konstantin T1 - БИОМЕХАНИКА ГЛАЗА: ТЕОРЕТИЧЕСКИЕ АСПЕКТЫ И КЛИНИЧЕСКИЕ ПРИЛОЖЕНИЯ T2 - Eye biomechanics : theoretical aspects and clinical applications Y1 - 2015 SN - 978-5-903025-57-2 PB - Real Time CY - Moscow ER - TY - CHAP A1 - Iomdina, Elena N. A1 - Kiseleva, Anna A. A1 - Kotliar, Konstantin A1 - Luzhnov, Petr V. T1 - Quantification of Choroidal Blood Flow Using the OCT-A System Based on Voxel Scan Processing T2 - 2020 International Conference on Biomedical Innovations and Applications (BIA) Y1 - 2020 SN - 978-1-7281-7073-2 U6 - http://dx.doi.org/10.1109/BIA50171.2020.9244511 SP - 41 EP - 44 ER - TY - JOUR A1 - Ismail, A.B.M. A1 - Harada, T. A1 - Yoshinobu, T. A1 - Iwasaki, H. A1 - Schöning, Michael Josef A1 - Lüth, H. T1 - Investigation of pulsed laser-deposited Al2O3 as a high pH-sensitive layer for LAPS-based biosensing applications JF - Sensors and Actuators B. 71 (2000), H. 3 Y1 - 2000 SN - 0925-4005 SP - 169 EP - 172 ER - TY - JOUR A1 - Itabashi, Akinori A1 - Kosaka, Naoki A1 - Miyamoto, Ko-ichiro A1 - Wagner, Torsten A1 - Schöning, Michael Josef T1 - High-speed chemical imaging system based on front-side-illuminated LAPS JF - Sensors and actuators B: Chemical N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of specific ions on the sensing surface. The conventional chemical imaging system based on the light-addressable potentiometric sensor (LAPS), however, required a long time to obtain a chemical image, due to the slow mechanical scan of a single light beam. For high-speed imaging, a plurality of light beams modulated at different frequencies can be employed to measure the ion concentrations simultaneously at different locations on the sensor plate by frequency division multiplex (FDM). However, the conventional measurement geometry of back-side illumination limited the bandwidth of the modulation frequency required for FDM measurement, because of the low-pass filtering characteristics of carrier diffusion in the Si substrate. In this study, a high-speed chemical imaging system based on front-side-illuminated LAPS was developed, which achieved high-speed spatiotemporal recording of pH change at a rate of 70 frames per second. Y1 - 2013 U6 - http://dx.doi.org/10.1016/j.snb.2013.03.016 SN - 1873-3077 VL - 182 SP - 315 EP - 321 PB - Elsevier CY - Amsterdam ER - TY - CHAP A1 - Jabbari, Medisa A1 - Bhattarai, Aroj A1 - Anding, Ralf A1 - Staat, Manfred ED - Erni, Daniel ED - Fischerauer, Alice ED - Himmel, Jörg ED - Seeger, Thomas ED - Thelen, Klaus T1 - Biomechanical simulation of different prosthetic meshes for repairing uterine/vaginal vault prolapse T2 - 2nd YRA MedTech Symposium 2017 : June 8th - 9th / 2017 / Hochschule Ruhr-West Y1 - 2017 SN - 978-3-9814801-9-1 U6 - http://dx.doi.org/10.17185/duepublico/43984 N1 - A young researchers track of the 7th IEEE Workshop & SENSORICA 2017 SP - 118 EP - 119 PB - Universität Duisburg-Essen CY - Duisburg ER - TY - CHAP A1 - Jablonski, Melanie A1 - Koch, Claudia A1 - Bronder, Thomas A1 - Poghossian, Arshak A1 - Wege, Christina A1 - Schöning, Michael Josef T1 - Field-Effect Biosensors Modified with Tobacco Mosaic Virus Nanotubes as Enzyme Nanocarrier T2 - MDPI Proceeding Y1 - 2017 U6 - http://dx.doi.org/10.3390/proceedings1040505 N1 - Eurosensors 2017 Conference, Paris, France, 3–6 September 2017 VL - 1 IS - 4 ER - TY - JOUR A1 - Jablonski, Melanie A1 - Münstermann, Felix A1 - Nork, Jasmina A1 - Molinnus, Denise A1 - Muschallik, Lukas A1 - Bongaerts, Johannes A1 - Wagner, Torsten A1 - Keusgen, Michael A1 - Siegert, Petra A1 - Schöning, Michael Josef T1 - Capacitive field‐effect biosensor applied for the detection of acetoin in alcoholic beverages and fermentation broths JF - physica status solidi (a) applications and materials science N2 - An acetoin biosensor based on a capacitive electrolyte–insulator–semiconductor (EIS) structure modified with the enzyme acetoin reductase, also known as butane-2,3-diol dehydrogenase (Bacillus clausii DSM 8716ᵀ), is applied for acetoin detection in beer, red wine, and fermentation broth samples for the first time. The EIS sensor consists of an Al/p-Si/SiO₂/Ta₂O₅ layer structure with immobilized acetoin reductase on top of the Ta₂O₅ transducer layer by means of crosslinking via glutaraldehyde. The unmodified and enzyme-modified sensors are electrochemically characterized by means of leakage current, capacitance–voltage, and constant capacitance methods, respectively. KW - acetoin KW - acetoin reductase KW - alcoholic beverages KW - biosensors KW - capacitive field-effect sensors Y1 - 2021 U6 - http://dx.doi.org/10.1002/pssa.202000765 SN - 1862-6319 VL - 218 IS - 13 PB - Wiley-VCH CY - Weinheim ER -