TY - JOUR A1 - Leschinger, Tim A1 - Birgel, Stefan A1 - Hackl, Michael A1 - Staat, Manfred A1 - Müller, Lars Peter A1 - Wegmann, Kilian T1 - A musculoskeletal shoulder simulation of moment arms and joint reaction forces after medialization of the supraspinatus footprint in rotator cuff repair JF - Computer Methods in Biomechanics and Biomedical Engineering Y1 - 2019 U6 - http://dx.doi.org/10.1080/10255842.2019.1572749 IS - Early view PB - Taylor & Francis CY - London ER - TY - JOUR A1 - Levers, A. A1 - Staat, Manfred A1 - Laack, Walter van T1 - Analyse der Langzeitwirkung der MBST® KernspinResonanzTherapie bei Gonarthrose T1 - Analysis of the Long-term Effect of the MBST® Nuclear Magnetic Resonance Therapy on Gonarthrosis N2 - Originalausgabe: Orthopädische Praxis Jg. 47. 2011 H. 11; S. 536-543. Mit freundlicher Genehmigung des Verlags Zusammenfassung: Auf der Basis von Patientenabfragen mittels Fragebogen zum Schmerzempfinden und zur Einschränkung bei Aktivitäten des alltäglichen Lebens wird die Langzeitwirkung der MBST® KernspinResonanz-Therapie bei Gonarthrose untersucht. An der Studie nahmen 39 Patienten teil, bei denen die Therapie bis zu vier Jahre zurückliegt. Neben einer Gesamtbetrachtung wird der Erfolg auch in Abhängigkeit von Alter, Geschlecht und sportlicher Aktivität analysiert. Insgesamt weist die Studie auf eine anhaltende Verbesserung des Gesundheitszustands mit zum Teil deutlicher Schmerzlinderung auch noch nach vier Jahren hin, jedoch mit einer leichten Schmerzzunahme gegen Ende des Untersuchungszeitraums von vier Jahren. Eine tendenziell positivere Wirkung bei Frauen, älteren Menschen oder auch sportlich nicht-aktiven Patienten lässt auf eine mögliche Beeinflussung des Erfolgs der Therapie durch (Über-)Belastung im Alltag schließen. Ein zusätzlich positiver Effekt der Therapie auf die Knochendichte ist ebenfalls denkbar, dies bleibt jedoch offen. N2 - Original edition: Orthopädische Praxis Vol. 47. 2011 Issue 11; P. 536-543. On the friendly authority of the publisher. Abstract: Based upon a questionnaire for patient-queries regarding pain-sensation and activity-restrictions during everyday task, the long-term effect of MBST® nuclear magnetic resonance therapy is studied in osteoarthritis of the knee. 39 patients, whose therapy dates back up to four years, participated in the study. In addition to an overall view, the success of this therapy is also analyzed regarding age, gender and physical activities. Overall, the study pointed out a sustained improvement in the patients´ local health-status with a significant pain-relief even after four years, but also with a slight increase in pain towards the end of that four-year period. There tends to be more positive effect on women, on elderly of also on even non-sports-active patients which suggest a possible influence by daily (over)-stressing on the success of the therapy. An additional positive effect of the therapy on bone density is also conceivable, however, this remains open. KW - Kniegelenkarthrose KW - Gonarthrose KW - MBST KW - Arthosetherapie KW - gonarthrosis KW - MBST KW - arthrosis therapy Y1 - 2011 ER - TY - JOUR A1 - Levers, A. A1 - Staat, Manfred A1 - Laack, Walter van T1 - Analysis of the long-term effect of the MBST® nuclear magnetic resonance therapy on gonarthrosis JF - Orthopedic Practice Y1 - 2016 VL - 47 IS - 11 SP - 521 EP - 528 ER - TY - JOUR A1 - Li, Anlan A1 - Shi, Young de A1 - Landsmann, B. A1 - Schankowski-Bouvier, P. A1 - Dikta, Gerhard A1 - Bauer, U. A1 - Artmann, Gerhard T1 - Hemorheology and walking distance of Peripheral Arterial Occlusive Disease patients during treatment with Ginkgo-biloba extract JF - Acta Pharmacologica Sinica = ZHONGUO YAOLI XUEBAO. 19 (1998), H. 5 Y1 - 1998 SN - 1745-7254 N1 - ISSN der parallelen Ausgabe 1671-4083; China-Zs.-Code: CN31-1347 abstract frei unter SP - 417 EP - 421 ER - TY - JOUR A1 - Linden, A. A1 - Fischöder, M. A1 - Laack, Walter van A1 - Staat, Manfred T1 - Einschränkung von Taluskippung und -vorschub durch Sprunggelenkorthesen nach fibularer Bandruptur JF - OUP Zeitschrift für die orthopädische und unfallchirurgische Praxis N2 - Die fibulare Bandruptur zählt zu einer der am häufigsten auftretenden Verletzungen des Bewegungsapparats. In den meisten Fällen wird heute die konservativ frühfunktionelle Therapie mit Sprunggelenkorthesen allgemein bevorzugt. Im Rahmen der vorliegenden Studie wurden 14 verschiedene Sprunggelenkorthesen im Hinblick auf ihre Einschränkung von Taluskippung und Talusvorschub untersucht. Zur Simulation einer fibularen Bandruptur wurde ein Unterschenkelmodell aus Holz mit Fußteil, mit angelegten Orthesen in einen Scheuba-Halteapparat eingespannt und mit 150 N seitlich sowie anterior-posterior belastet. Anhand der erstellten "gehaltenen" Röntgenaufnahmen konnten Taluskippung und Talusvorschub jeder einzelnen Orthese eindeutig bestimmt werden. Die meisten Orthesen erreichten zufriedenstellende Ergebnisse. Es stellte sich heraus, dass vor allem eine eng anliegende, im Gelenkbereich anatomisch angepasste Form vorteilhaft zu sein scheint. N2 - The ankle sprain is actually one of the most common injuries. Nowadays the conservative pre-functional therapy with ankle braces is generally preferred. In the present study 14 different ankle braces were tested with regard to their ability to constrict the talar tilt and anterior drawer displacement. As part of the tests a wooden model of a foot was used in order to simulate an ankle sprain. This model was clamped in a Scheuba-device with different ankle braces and a force of 150 N was applied to it. The stress radiographs showed different talar tilts and anterior drawers of each brace. Most ankle braces achieved a satisfying result. It has become obvious that a tight fitting and an anatomically designed shape seem to be favourable. T2 - Constraint of talar tilt and anterior drawer by different ankle braces after the rupture of fibular ligaments KW - Sprunggelenkorthesen KW - fibulare Bandruptur KW - Distorsion des oberen Sprunggelenks KW - ankle sprain KW - rupture of the fibular ligament KW - ankle braces Y1 - 2013 SN - 2193-5785 U6 - http://dx.doi.org/10.3238/oup.2013.0306-0309 VL - 2 IS - 6 SP - 306 EP - 309 PB - Deutscher Ärzte-Verl. CY - Köln ER - TY - JOUR A1 - Linder, Peter A1 - Beckler, Matthias A1 - Doerr, Leo A1 - Stoelzle-Feix, Sonja A1 - Fertig, Niels A1 - Jung, Alexander A1 - Staat, Manfred A1 - Gossmann, Matthias T1 - A new in vitro tool to investigate cardiac contractility under physiological mechanical conditions JF - Journal of Pharmacological and Toxicological Methods Y1 - 2019 U6 - http://dx.doi.org/10.1016/j.vascn.2019.05.162 SN - 1056-8719 VL - 99 IS - Article number 106595 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Linder, Peter A1 - Digel, Ilya A1 - Temiz Artmann, Aysegül A1 - Kayser, Peter A1 - Porst, Dariusz A1 - Artmann, Gerhard T1 - High-throughput testing of mechanical forces generated in thin cell and tissue layers JF - Tissue Engineering. 13 (2007), H. 7 Y1 - 2007 SN - 1076-3279 N1 - Meeting abstract 433 SP - 1778 EP - 1778 ER - TY - JOUR A1 - Liphardt, Anna-Maria A1 - Fernandez-Gonzalo, Rodrigo A1 - Albracht, Kirsten A1 - Rittweger, Jörn A1 - Vico, Laurence T1 - Musculoskeletal research in human space flight – unmet needs for the success of crewed deep space exploration JF - npj Microgravity N2 - Based on the European Space Agency (ESA) Science in Space Environment (SciSpacE) community White Paper “Human Physiology – Musculoskeletal system”, this perspective highlights unmet needs and suggests new avenues for future studies in musculoskeletal research to enable crewed exploration missions. The musculoskeletal system is essential for sustaining physical function and energy metabolism, and the maintenance of health during exploration missions, and consequently mission success, will be tightly linked to musculoskeletal function. Data collection from current space missions from pre-, during-, and post-flight periods would provide important information to understand and ultimately offset musculoskeletal alterations during long-term spaceflight. In addition, understanding the kinetics of the different components of the musculoskeletal system in parallel with a detailed description of the molecular mechanisms driving these alterations appears to be the best approach to address potential musculoskeletal problems that future exploratory-mission crew will face. These research efforts should be accompanied by technical advances in molecular and phenotypic monitoring tools to provide in-flight real-time feedback. Y1 - 2023 U6 - http://dx.doi.org/10.1038/s41526-023-00258-3 SN - 2373-8065 VL - 9 IS - Article number: 9 SP - 1 EP - 9 PB - Springer Nature ER - TY - JOUR A1 - Lustfeld, H. A1 - Hirschfeld, J. A. A1 - Reißel, Martin A1 - Steffen, B. T1 - Enhancement of precision and reduction of measuring points in tomographic reconstructions JF - Physics Letters A Y1 - 2011 SN - 0375-9601 VL - 375 IS - 8 SP - 1167 EP - 1171 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Lustfeld, H. A1 - Pithan, C. A1 - Reißel, Martin T1 - Metallic electrolyte composites in the framework of the brick-layer model JF - Journal of the European Ceramic Society N2 - It is well known that the already large dielectric constants of some electrolytes like BaTiO₃ can be enhanced further by adding metallic (e.g. Ni, Cu or Ag) nanoparticles. The enhancement can be quite large, a factor of more than 1000 is possible. The consequences for the properties will be discussed in the present paper applying a brick-layer model (BLM) for calculating dc-resistivities of thin layers and a modified one (PBLM) that includes percolation for calculating dielectric properties of these materials. The PBLM results in an at least qualitative description and understanding of the physical phenomena: This model gives an explanation for the steep increase of the dielectric constant below the percolation threshold and why this increase is connected to a dramatic decrease of the breakdown voltage as well as the ability of storing electrical energy. We conclude that metallic electrolyte composites like BaTiO₃ are not appropriate for energy storage. Y1 - 2012 U6 - http://dx.doi.org/10.1016/j.jeurceramsoc.2011.10.017 SN - 0955-2219 VL - 32 IS - 4 SP - 859 EP - 864 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Lüth, H. A1 - Thust, M. A1 - Steffen, A. A1 - Kordos, P. A1 - Schöning, Michael Josef T1 - Biochemical sensors with structured and porous silicon capacitors JF - Materials Science and Engineering B. 69-70 (2000) Y1 - 2000 SN - 0921-5107 SP - 104 EP - 108 ER - TY - JOUR A1 - Maggakis-Kelemen, Christina A1 - Biselli, Manfred A1 - Artmann, Gerhard T1 - Determination of the elastic shear modulus of cultured human red blood cells JF - Biomedizinische Technik. 47 (2002), H. Suppl. 1 Pt. 1 Y1 - 2002 SN - 0013-5585 N1 - Druckausgabe unter 63 Z 471 vorhanden SP - 106 EP - 109 ER - TY - JOUR A1 - Maggakis-Kelemen, Christina A1 - Digel, Ilya A1 - Artmann, Gerhard T1 - Polystyrene sulfonate/Polyallylamine hydrochloride microcapsules as potential artificial red blood cells - improvement of capsule flexibility JF - Biomedizinische Technik. 50 (2005), H. Erg.-Bd. 1 Y1 - 2005 SP - 324 EP - 326 ER - TY - JOUR A1 - Maier, M. M. A1 - Feucht, N. A1 - Winkler von Mohrenfels, C. A1 - Kotliar, Konstantin A1 - Fabian, E. A1 - Lohmann, C. P. T1 - Nahtlose Cerclage mit Skleratunnelfixation. Sutureless Encircling Band - Clinical Experience JF - Klinische Monatsblätter für Augenheilkunde Y1 - 2011 SN - 0344-6360 VL - 228 IS - 5 SP - 473 EP - 476 PB - Thieme CY - Stuttgart ER - TY - JOUR A1 - Malan, Leone A1 - Hamer, Mark A1 - Känel, Roland von A1 - Kotliar, Konstantin A1 - Wyk, Roelof D. van A1 - Lambert, Gavin W. A1 - Vilser, Walthard A1 - Ziemssen, Tjalf A1 - Schlaich, Markus P. A1 - Smith, Wayne A1 - Magnusson, Martin A1 - Wentzel, Annemarie A1 - Myburgh, Carlien E. A1 - Steyn, Hendrik S. A1 - Malan, Nico T. T1 - Delayed retinal vein recovery responses indicate both non-adaptation to stress as well as increased risk for stroke: the SABPA study JF - Cardiovascular Journal of Africa Y1 - 2020 U6 - http://dx.doi.org/10.5830/CVJA-2020-031 SN - 1680-0745 VL - 26 IS - 31 SP - 1 EP - 12 PB - Clinics Cardive Publishing CY - Durbanville ER - TY - JOUR A1 - Malik, A. M. A1 - Abdieva, G. Zh. A1 - Ualieva, P. S. A1 - Zhubanova, A. A. A1 - Temiz Artmann, Aysegül T1 - CКPИНИНГ МИКPOOPГAНИЗМOВ-ДECТPУКТOPOВ XЛOРOPГAНИЧECКИX ЗAГPЯЗНИТEЛEЙ T1 - Screening of microorganisms – destructors of chlororganic pollutants JF - Eurasian Journal of Ecology Y1 - 2019 SN - 2617-7358 VL - 61 IS - 4 SP - 61 EP - 71 ER - TY - JOUR A1 - Malinowski, Daniel A1 - Fournier, Yvan A1 - Horbach, Andreas A1 - Frick, Michael A1 - Magliani, Mirko A1 - Kalverkamp, Sebastian A1 - Hildinger, Martin A1 - Spillner, Jan A1 - Behbahani, Mehdi A1 - Hima, Flutura T1 - Computational fluid dynamics analysis of endoluminal aortic perfusion JF - Perfusion N2 - Introduction: In peripheral percutaneous (VA) extracorporeal membrane oxygenation (ECMO) procedures the femoral arteries perfusion route has inherent disadvantages regarding poor upper body perfusion due to watershed. With the advent of new long flexible cannulas an advancement of the tip up to the ascending aorta has become feasible. To investigate the impact of such long endoluminal cannulas on upper body perfusion, a Computational Fluid Dynamics (CFD) study was performed considering different support levels and three cannula positions. Methods: An idealized literature-based- and a real patient proximal aortic geometry including an endoluminal cannula were constructed. The blood flow was considered continuous. Oxygen saturation was set to 80% for the blood coming from the heart and to 100% for the blood leaving the cannula. 50% and 90% venoarterial support levels from the total blood flow rate of 6 l/min were investigated for three different positions of the cannula in the aortic arch. Results: For both geometries, the placement of the cannula in the ascending aorta led to a superior oxygenation of all aortic blood vessels except for the left coronary artery. Cannula placements at the aortic arch and descending aorta could support supra-aortic arteries, but not the coronary arteries. All positions were able to support all branches with saturated blood at 90% flow volume. Conclusions: In accordance with clinical observations CFD analysis reveals, that retrograde advancement of a long endoluminal cannula can considerably improve the oxygenation of the upper body and lead to oxygen saturation distributions similar to those of a central cannulation. KW - computational fluid dynamics analysis KW - simulation KW - endoluminal KW - aortic perfusion KW - extracorporeal membrane oxygenation Y1 - 2022 U6 - http://dx.doi.org/10.1177/02676591221099809 SN - 1477-111X VL - 0 IS - 0 SP - 1 EP - 8 PB - Sage CY - London ER - TY - JOUR A1 - Malzahn, Kerstin A1 - Windmiller, Joshua Ray A1 - Valdés-Ramírez, Gabriela A1 - Wang, Joseph A1 - Schöning, Michael Josef T1 - Wearable electrochemical sensors for in situ analysis in marine environments JF - Analyst. 136 (2011), H. 14 Y1 - 2011 SN - 0003-2654 SP - 2912 EP - 2917 PB - Royal Society of Chemistry CY - Cambridge ER - TY - JOUR A1 - Mandekar, Swati A1 - Holland, Abigail A1 - Thielen, Moritz A1 - Behbahani, Mehdi A1 - Melnykowycz, Mark T1 - Advancing towards Ubiquitous EEG, Correlation of In-Ear EEG with Forehead EEG JF - Sensors N2 - Wearable EEG has gained popularity in recent years driven by promising uses outside of clinics and research. The ubiquitous application of continuous EEG requires unobtrusive form-factors that are easily acceptable by the end-users. In this progression, wearable EEG systems have been moving from full scalp to forehead and recently to the ear. The aim of this study is to demonstrate that emerging ear-EEG provides similar impedance and signal properties as established forehead EEG. EEG data using eyes-open and closed alpha paradigm were acquired from ten healthy subjects using generic earpieces fitted with three custom-made electrodes and a forehead electrode (at Fpx) after impedance analysis. Inter-subject variability in in-ear electrode impedance ranged from 20 kΩ to 25 kΩ at 10 Hz. Signal quality was comparable with an SNR of 6 for in-ear and 8 for forehead electrodes. Alpha attenuation was significant during the eyes-open condition in all in-ear electrodes, and it followed the structure of power spectral density plots of forehead electrodes, with the Pearson correlation coefficient of 0.92 between in-ear locations ELE (Left Ear Superior) and ERE (Right Ear Superior) and forehead locations, Fp1 and Fp2, respectively. The results indicate that in-ear EEG is an unobtrusive alternative in terms of impedance, signal properties and information content to established forehead EEG. KW - in-ear EEG KW - correlation KW - forehead EEG KW - impedance spectroscopy KW - biopotential electrodes Y1 - 2022 U6 - http://dx.doi.org/10.3390/s22041568 SN - 1424-8220 VL - 22 IS - 4 SP - 1 EP - 19 PB - MDPI CY - Basel ER - TY - CHAP A1 - Mandekar, Swati A1 - Jentsch, Lina A1 - Lutz, Kai A1 - Behbahani, Mehdi A1 - Melnykowycz, Mark T1 - Earable design analysis for sleep EEG measurements T2 - UbiComp '21 N2 - Conventional EEG devices cannot be used in everyday life and hence, past decade research has been focused on Ear-EEG for mobile, at-home monitoring for various applications ranging from emotion detection to sleep monitoring. As the area available for electrode contact in the ear is limited, the electrode size and location play a vital role for an Ear-EEG system. In this investigation, we present a quantitative study of ear-electrodes with two electrode sizes at different locations in a wet and dry configuration. Electrode impedance scales inversely with size and ranges from 450 kΩ to 1.29 MΩ for dry and from 22 kΩ to 42 kΩ for wet contact at 10 Hz. For any size, the location in the ear canal with the lowest impedance is ELE (Left Ear Superior), presumably due to increased contact pressure caused by the outer-ear anatomy. The results can be used to optimize signal pickup and SNR for specific applications. We demonstrate this by recording sleep spindles during sleep onset with high quality (5.27 μVrms). KW - EEG KW - sensors KW - Impedance Spectroscopy KW - Sleep EEG KW - biopotential electrodes Y1 - 2021 U6 - http://dx.doi.org/10.1145/3460418.3479328 N1 - UbiComp '21: Adjunct Proceedings of the 2021 ACM International Joint Conference on Pervasive and Ubiquitous Computing and Proceedings of the 2021 ACM International Symposium on Wearable Computers, September 21–26, 2021, Virtual, USA SP - 171 EP - 175 ER -