TY - JOUR A1 - Kowalewski, Paul A1 - Bragard, Michael A1 - Hüning, Felix A1 - De Doncker, Rik W. T1 - An inexpensive Wiegand-sensor-based rotary encoder without rotating magnets for use in electrical drives JF - IEEE Transactions on Instrumentation and Measurement N2 - This paper introduces an inexpensive Wiegand-sensor-based rotary encoder that avoids rotating magnets and is suitable for electrical-drive applications. So far, Wiegand-sensor-based encoders usually include a magnetic pole wheel with rotating permanent magnets. These encoders combine the disadvantages of an increased magnet demand and a limited maximal speed due to the centripetal force acting on the rotating magnets. The proposed approach reduces the total demand of permanent magnets drastically. Moreover, the rotating part is manufacturable from a single piece of steel, which makes it very robust and cheap. This work presents the theoretical operating principle of the proposed approach and validates its benefits on a hardware prototype. The presented proof-of-concept prototype achieves a mechanical resolution of 4.5 ° by using only 4 permanent magnets, 2Wiegand sensors and a rotating steel gear wheel with 20 teeth. KW - Rotary encoder KW - Wiegand sensor Y1 - 2023 U6 - https://doi.org/10.1109/TIM.2023.3326166 SN - 0018-9456 (Print) SN - 1557-9662 (Online) VL - 72 SP - 10 Seiten PB - IEEE CY - New York ER - TY - JOUR A1 - Kobus, Thiele A1 - Bitz, Andreas A1 - Uden, Mark J. van A1 - Lagemaat, Miram W. A1 - Rothgang, Eva A1 - Orzada, Stephan A1 - Heerschap, Arend A1 - Scheenen, Tom W. J. T1 - In vivo 31P MR spectroscopic imaging of the human prostate at 7 T: safety and feasibility JF - Magnetic Resonance in Medicine N2 - 31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and Burn:x-wiley:07403194:media:MRM24175:tex2gif-stack-1 measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer. Y1 - 2012 U6 - https://doi.org/10.1002/mrm.24175 SN - 1522-2594 VL - 68 IS - 6 SP - 1683 EP - 1695 PB - Wiley-Liss CY - New York ER - TY - JOUR A1 - Kob, Malte A1 - Frauenrath, Tobias T1 - A system for parallel measurement of glottis opening and larynx position JF - Biomedical Signal Processing and Control N2 - The simultaneous assessment of glottal dynamics and larynx position can be beneficial for the diagnosis of disordered voice or speech production and swallowing. Up to now, methods either concentrate on assessment of the glottis opening using optical, acoustical or electrical (electroglottography, EGG) methods, or on visualisation of the larynx position using ultrasound, computer tomography or magnetic resonance imaging techniques. The method presented here makes use of a time-multiplex measurement approach of space-resolved transfer impedances through the larynx. The fast sequence of measurements allows a quasi simultaneous assessment of both larynx position and EGG signal using up to 32 transmit–receive signal paths. The system assesses the dynamic opening status of the glottis as well as the vertical and back/forward motion of the larynx. Two electrode-arrays are used for the measurement of the electrical transfer impedance through the neck in different directions. From the acquired data the global and individual conductivity is calculated as well as a 2D point spatial representation of the minimum impedance. The position information is shown together with classical EGG signals allowing a synchronous visual assessment of glottal area and larynx position. A first application to singing voice analysis is presented that indicate a high potential of the method for use as a non-invasive tool in the diagnosis of voice, speech, and swallowing disorders. KW - EGG KW - Transfer impedance KW - Tomography KW - Larynx position KW - Voice assessment Y1 - 2009 U6 - https://doi.org/10.1016/j.bspc.2009.03.004 SN - 1746-8108 VL - 4 IS - 3 SP - 221 EP - 228 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Klomp, D. W. J. A1 - Bitz, Andreas A1 - Heerschap, A. A1 - Scheenen, T. W. J. T1 - Proton spectroscopic imaging of the human prostate at 7 T JF - NMR in Biomedicine Y1 - 2009 U6 - https://doi.org/10.1002/nbm.1360 SN - 1099-1492 VL - 22 IS - 5 SP - 495 EP - 501 ER - TY - JOUR A1 - Klinge, Uwe A1 - Wilke, Ralf A1 - Mühl, Thomas T1 - Auswahl der Herniennetze nach der “effektiven Porosität” - warum das Gewicht weniger wichtig ist JF - Chirurgische Allgemeine : CHAZ ; Zeitung für Klinik und Praxis Y1 - 2012 SN - 1615-5378 VL - 13 IS - 12 SP - 297 EP - 301 PB - Kaden CY - Mannheim ER - TY - JOUR A1 - Klinge, Uwe A1 - Otto, Jens A1 - Mühl, Thomas T1 - High Structural Stability of Textile Implants Prevents Pore Collapse and Preserves Effective Porosity at Strain JF - BioMed Research International Y1 - 2015 U6 - https://doi.org/10.1155/2015/953209 SN - 2314-6133 (Print) SN - 2314-6141 (Online) N1 - Article ID: 953209 VL - 2015 ER - TY - JOUR A1 - Jens, Otto A1 - Kaldenhoff, E. A1 - Kirschner-Hermanns, R. A1 - Mühl, Thomas A1 - Klinge, Uwe T1 - Elongation of textile pelvic floor implants under load is related to complete loss of effective porosity, thereby favoring incorporation in scar plates JF - Journal of biomedical materials research. Part A N2 - Use of textile structures for reinforcement of pelvic floor structures has to consider mechanical forces to the implant, which are quite different to the tension free conditions of the abdominal wall. Thus, biomechanical analysis of textile devices has to include the impact of strain on stretchability and effective porosity. Prolift® and Prolift + M®, developed for tension free conditions, were tested by measuring stretchability and effective porosity applying mechanical strain. For comparison, we used Dynamesh-PR4®, which was designed for pelvic floor repair to withstand mechanical strain. Prolift® at rest showed moderate porosity with little stretchability but complete loss of effective porosity at strain of 4.9 N/cm. Prolift + M® revealed an increased porosity at rest, but at strain showed high stretchability, with subsequent loss of effective porosity at strain of 2.5 N/cm. Dynamesh PR4® preserved its high porosity even under strain, but as consequence of limited stretchability. Though in tension free conditions Prolift® and Prolift + M® can be considered as large pore class I meshes, application of mechanical strain rapidly lead to collapse of pores. The loss of porosity at mechanical stress can be prevented by constructions with high structural stability. Assessment of porosity under strain was found helpful to define requirements for pelvic floor devices. Clinical studies have to prove whether devices with high porosity as well as high structural stability can improve the patients' outcome. Y1 - 2014 U6 - https://doi.org/10.1002/jbm.a.34767 SN - 1552-4965 VL - 102 IS - 4 SP - 1079 EP - 1084 PB - Wiley CY - New York ER - TY - JOUR A1 - Hüning, Felix A1 - Wilke, I. A1 - Nakielski, G. A1 - Kotzler, J. T1 - Dynamic conductivity of YBCO thin films from low to very high frequencies / Wilke, I. ; Nakielski, G. ; Kotzler, J. ; Subke, K. O. ; Jaekel, C. ; Hüning, F. ; Roskos, H. G. ; Kurz, Heinrich JF - Applied superconductivity 1997 : proceedings of EUCAS 1997, the Third European Conference on Applied Superconductivity, held in the Netherlands, 30 June - 3 July 1997 / ed. by H. Rogalla Y1 - 1997 SN - 0-7503-0487-1 N1 - Institute of Physics conference series 158 SP - 121 EP - 124 PB - IOP CY - Bristol ER - TY - JOUR A1 - Hüning, Felix A1 - Sparta, K. A1 - Redhammer, G. J. A1 - Roussel, P. T1 - Structural Phase Transition in the 2D Spin Dimer Compound SrCu2(BO3)2 / Sparta, K. ; Redhammer, G. J. ; Roussel, P. ; Heger, G. ; Roth, G. ; Ionescu, A. Lemmens, P. ; Grove, M. ; Güntherrodt, G. ; Hüning, F. ; Lueken, H. ; Kageyama, H. ; Onizuka, K ; Ueda JF - The European Physical Journal B - Condensed Matter and Complex Systems. 19 (2001), H. 4 Y1 - 2001 SN - 1434-6036 SP - 507 EP - 516 PB - - ER - TY - JOUR A1 - Hüning, Felix A1 - Luken, Heiko A1 - Schilder, Herbert A1 - Eifert, Thomas T1 - Magnetochemistry: Compounds and Concepts / Lueken, Heiko ; Schilder, Herbert ; Eifert, Thomas ; Handrick, Klaus ; Hüning, Felix JF - Advances in Solid State Physics. 201 (2001) Y1 - 2001 SP - 515 EP - 532 PB - - ER - TY - JOUR A1 - Hüning, Felix A1 - Leineweber, A. A1 - Jacobs, H. A1 - Lueken, H. T1 - ε-Fe3N: magnetic structure, magnetization and temperature dependent disorder of nitrogen / Leineweber, A. ; Jacobs, H. ; Hüning, F. ; Lueken, H. ; Schilder, H. ; Kockelmann, W. JF - Journal of Alloys and Compounds. 288 (1999), H. 1-2 N2 - ε-Fe3N has been investigated by time-of-flight neutron diffraction (temperature range 4.2–618 K) and SQUID magnetometry (2–700 K, B≤5 T). A ferromagnetic spin structure is observed with magnetic moments oriented perpendicular to the c-axis of the hexagonal nuclear structure. The magnetic saturation moment of iron is 2.2 μB at 4.2 K from neutron diffraction and 2.0 μB from magnetic measurements and decreases in a Brillouin-like manner on heating to TC=575 K. Above 450 K an increasing but reversible disorder of the nitrogen partial structure is observed. Y1 - 1999 SN - 1873-4669 VL - 288 IS - 1-2 SP - 79 EP - 87 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Hüning, Felix A1 - Leineweber, A. A1 - Jacobs, H. A1 - Lueken, H. T1 - Nitrogen Ordering and ferromagnetic properties of -Fe3N1+x (0.10  x  0.39) and -Fe3(N0.80C0.20)1.38 / Leineweber, A. ; Jacobs, H. ; Hüning, F. ; Lueken, H. ; Kockelmann, W. JF - Journal of Alloys and Compounds. 316 (2001), H. 1-2 Y1 - 2001 SN - 1873-4669 SP - 21 EP - 38 PB - - ER - TY - JOUR A1 - Hüning, Felix A1 - Jaekel, C. A1 - Francois, I. A1 - Kyas, G. T1 - Microwave surface impedance measurements on high-Tc superconductors / Jaekel, C. ; Francois, I. ; Kyas, G. ; Hüning, F. ; Roskos, H. G. ; Borghs, G. ; Kurz, H. JF - Czechoslovak Journal of Physics. 46 (1996), H. Suppl. 2 Y1 - 1996 SN - 1572-9486 IS - 46 SP - 1117 EP - 1118 PB - Springer Science+Business Media CY - Dordrecht ER - TY - JOUR A1 - Hüning, Felix A1 - Heuermann, Holger A1 - Wache, Franz-Josef A1 - Jajo, Rami Audisho T1 - A new wireless sensor interface using dual-mode radio JF - Journal of Sensors and Sensor Systems : JSSS N2 - The integration of sensors is one of the major tasks in embedded, control and “internet of things” (IoT) applications. For the integration mainly digital interfaces are used, starting from rather simple pulse-width modulation (PWM) interface to more complex interfaces like CAN (Controller Area Network). Even though these interfaces are tethered by definition, a wireless realization is highly welcome in many applications to reduce cable and connector cost, increase the flexibility and realize new emerging applications like wireless control systems. Currently used wireless solutions like Bluetooth, WirelessHART or IO-Link Wireless use dedicated communication standards and corresponding higher protocol layers to realize the wireless communication. Due to the complexity of the communication and the protocol handling, additional latency and jitter are introduced to the data communication that can meet the requirements for many applications. Even though tunnelling of other bus data like CAN data is generally also possible the latency and jitter prevent the tunnelling from being transparent for the bus system. Therefore a new basic technology based on dual-mode radio is used to realize a wireless communication on the physical layer only, enabling a reliable and real-time data transfer. As this system operates on the physical layer it is independent of any higher layers of the OSI (open systems interconnection) model. Hence it can be used for several different communication systems to replace the tethered physical layer. A prototype is developed and tested for real-time wireless PWM, SENT (single-edge nibble transmission) and CAN data transfer with very low latency and jitter. Y1 - 2018 U6 - https://doi.org/10.5194/jsss-7-507-2018 VL - Volume 7 IS - 2 SP - 507 EP - 515 PB - Copernicus Publ. CY - Göttingen ER - TY - JOUR A1 - Hüning, Felix A1 - Heuermann, Holger A1 - Wache, Franz-Josef T1 - Wireless CAN without WLAN or Bluetooth JF - CAN Newsletter N2 - In two developed concepts, dual-mode radio enables CAN participants to be integrated wirelessly into a CAN network. Constructed from a few components, a protocol-free, real-time transmission and thus transparent integration into CAN is provided. Y1 - 2018 IS - December 2018 SP - 44 EP - 46 ER - TY - JOUR A1 - Hüning, Felix A1 - Heuermann, Holger A1 - Wache, Franz-Josef T1 - Wireless CAN JF - Etz: Elektrotechnik & Automation N2 - In modernen elektronischen und mechatronischen Systemen, z. B. im industriellen oder automobil Bereich, kommunizieren eingebettete Steuergeräte und Sensoren vielfach über Bussysteme wie CAN oder LIN. Die Kommunikation findet in der Regel drahtgebunden statt, so dass der Kabelbaum für die Kommunikation sehr groß werden kann. Daher ist es naheliegend, Leitungen und dazugehörige Stecker, z. B. für nicht-sicherheitskritische Komfortsysteme, einzusparen und diese durch gerichtete Funkstrecken für kurze Entfernungen zu ersetzen. Somit könnten Komponenten wie ECUs oder Sensoren kabel- und steckerlos in ein Bussystem integriert werden. Zudem ist eine einfache galvanische und mechanische Trennung zu erreichen. Funkübertragung wird bei diesen Bussystemen derzeit nicht eingesetzt, da insbesondere die Echtzeitfähigkeit und die Robustheit der vorhandenen Funksysteme nicht den Anforderungen der Anwendungen entspricht. Zudem sind bestehende Funksysteme wie WLAN oder Bluetooth im Vergleich zur konventionellen Verkabelung teuer und es besteht hierbei die Möglichkeit, dass sie ausspioniert werden können und so sensible Daten entwendet werden können. In dieser Arbeit wird eine alternative Realisierung zu den bestehenden Funksystemen vorgestellt, die aus wenigen Komponenten aufzubauen ist. Es ist eine protokolllose, echtzeitfähige Übertragung möglich und somit die transparente Integration in ein Bussystem wie CAN. Y1 - 2018 SN - 0170-1711 VL - 139 IS - 10 SP - 22 EP - 26 PB - VDE-Verlag CY - Wuppertal ER - TY - JOUR A1 - Hüning, Felix A1 - Eifert, T. A1 - Lueken, H. A1 - Schmidt, P. T1 - High-temperature series expansion of the magnetic susceptibility of extended magnetic systems in a complete computer implementation / Eifert, T. ; Hüning, F. ; Lueken, H. ; Schmidt, P. ; Thiele, G. JF - Chemical Physics Letters. 364 (2002), H. 1-2 Y1 - 2002 SN - 0009-2614 SP - 69 EP - 74 PB - - ER - TY - JOUR A1 - Hüning, Felix A1 - Eifert, T. A1 - Handrick, K. A1 - Neuhausen, U. T1 - Computational Magnetochemistry: Complementary Quantum Mechanical Tools / Eifert, T. ; Handrick, K. ; Hüning, F. ; Neuhausen, U. ; Schilder, H. ; Lueken, H. JF - Zeitschrift für Anorganische und Allgemeine Chemie (ZAAC) - Journal of Inorganic and General Chemistry . 632 (2006), H. 4 Y1 - 2006 SN - 1521-3749 SP - 521 EP - 529 PB - - ER - TY - JOUR A1 - Hüning, Felix A1 - Eifert, T. A1 - Handrick, K. A1 - Neuhausen, U. T1 - Computational Magnetochemistry: Complementary Quantum Mechanical Tools / Eifert, T. ; Handrick, K. ; Hüning, F. ; Neuhausen, U. ; Schilder, H. ; Lueken, H. JF - 20 Jahre Wilhelm-Klemm-Stiftung / Kuratorium der Wilhelm-Klemm-Stiftung (Hrsg.) Y1 - 2006 SN - 978-3-8322-5520-6 SP - 193ff PB - Shaker CY - Aachen ER - TY - JOUR A1 - Hüning, Felix A1 - De Matteis, Stefan T1 - Entwicklung eines taktilen HMI für sehbehinderte und blinde Nutzerinnen und Nutzer JF - Blind - sehbehindert Y1 - 2020 SN - 0176-7836 VL - 140 IS - 2 SP - 9 EP - 19 PB - Edition Bentheim CY - Würzburg ER -