TY - JOUR A1 - Simonis, A. A1 - Lüth, H. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - New concepts of miniaturised reference electrodes in silicon technology for potentiometric sensor systems JF - Sensors and Actuators B. 103 (2004), H. 1-2 Y1 - 2004 SN - 0925-4005 SP - 429 EP - 435 ER - TY - JOUR A1 - Simonis, A. A1 - Krings, T. A1 - Lüth, H. A1 - Wang, J. A1 - Schöning, Michael Josef T1 - A „hybrid“ thin-film pH sensor with integrated thick-film reference JF - Sensors. 1 (2001), H. 6 Y1 - 2001 SN - 1424-8220 SP - 183 EP - 192 ER - TY - JOUR A1 - Simonis, A. A1 - Dawgul, M. A1 - Lüth, H. A1 - Schöning, Michael Josef T1 - Miniaturised reference electrodes for field-effect sensors compatible to silicon chip technology JF - Electrochimica Acta. 51 (2005), H. 5 Y1 - 2005 SN - 0013-4686 U6 - https://doi.org/10.1016/j.electacta.2005.04.063 SP - 930 EP - 937 ER - TY - JOUR A1 - Sildatke, Michael A1 - Karwanni, Hendrik A1 - Kraft, Bodo A1 - Zündorf, Albert T1 - A distributed microservice architecture pattern for the automated generation of information extraction pipelines JF - SN Computer Science N2 - Companies often build their businesses based on product information and therefore try to automate the process of information extraction (IE). Since the information source is usually heterogeneous and non-standardized, classic extract, transform, load techniques reach their limits. Hence, companies must implement the newest findings from research to tackle the challenges of process automation. They require a flexible and robust system that is extendable and ensures the optimal processing of the different document types. This paper provides a distributed microservice architecture pattern that enables the automated generation of IE pipelines. Since their optimal design is individual for each input document, the system ensures the ad-hoc generation of pipelines depending on specific document characteristics at runtime. Furthermore, it introduces the automated quality determination of each available pipeline and controls the integration of new microservices based on their impact on the business value. The introduced system enables fast prototyping of the newest approaches from research and supports companies in automating their IE processes. Based on the automated quality determination, it ensures that the generated pipelines always meet defined business requirements when they come into productive use. KW - Architectural design KW - Model-driven software engineering KW - Software and systems modeling KW - Enterprise information systems KW - Information extraction Y1 - 2023 U6 - https://doi.org/10.1007/s42979-023-02256-4 SN - 2661-8907 N1 - Corresponding authors: Michael Sildatke, Hendrik Karwanni IS - 4, Article number: 833 PB - Springer Singapore CY - Singapore ER - TY - CHAP A1 - Sildatke, Michael A1 - Karwanni, Hendrik A1 - Kraft, Bodo A1 - Schmidts, Oliver A1 - Zündorf, Albert T1 - Automated Software Quality Monitoring in Research Collaboration Projects T2 - ICSEW'20: Proceedings of the IEEE/ACM 42nd International Conference on Software Engineering Workshops N2 - In collaborative research projects, both researchers and practitioners work together solving business-critical challenges. These projects often deal with ETL processes, in which humans extract information from non-machine-readable documents by hand. AI-based machine learning models can help to solve this problem. Since machine learning approaches are not deterministic, their quality of output may decrease over time. This fact leads to an overall quality loss of the application which embeds machine learning models. Hence, the software qualities in development and production may differ. Machine learning models are black boxes. That makes practitioners skeptical and increases the inhibition threshold for early productive use of research prototypes. Continuous monitoring of software quality in production offers an early response capability on quality loss and encourages the use of machine learning approaches. Furthermore, experts have to ensure that they integrate possible new inputs into the model training as quickly as possible. In this paper, we introduce an architecture pattern with a reference implementation that extends the concept of Metrics Driven Research Collaboration with an automated software quality monitoring in productive use and a possibility to auto-generate new test data coming from processed documents in production. Through automated monitoring of the software quality and auto-generated test data, this approach ensures that the software quality meets and keeps requested thresholds in productive use, even during further continuous deployment and changing input data. Y1 - 2020 U6 - https://doi.org/10.1145/3387940.3391478 N1 - ICSE '20: 42nd International Conference on Software Engineering, Seoul, Republic of Korea, 27 June 2020 - 19 July 2020 SP - 603 EP - 610 PB - IEEE CY - New York, NY ER - TY - CHAP A1 - Siebigteroth, Ines A1 - Kraft, Bodo A1 - Schmidts, Oliver A1 - Zündorf, Albert T1 - A Study on Improving Corpus Creation by Pair Annotation T2 - Proceedings of the Poster Session of the 2nd Conference on Language, Data and Knowledge (LDK-PS 2019) Y1 - 2019 SN - 1613-0073 SP - 40 EP - 44 ER - TY - JOUR A1 - Seynnes, O. R. A1 - Bojsen-Moller, J. A1 - Albracht, Kirsten A1 - Arndt, A. A1 - Cronin, N. J. A1 - Finni, T. A1 - Magnusson, S. P. T1 - Ultrasound-based testing of tendon mechanical properties: a critical evaluation JF - Journal of Applied Physiology Y1 - 2015 U6 - https://doi.org/10.1152/japplphysiol.00849.2014 SN - 8750-7587 VL - 118 IS - 2 SP - 133 EP - 141 ER - TY - JOUR A1 - Seifarth, Volker A1 - Schehl, D. A1 - Linder, Peter A1 - Gossmann, Matthias A1 - Digel, Ilya A1 - Artmann, Gerhard A1 - Porst, Dariusz A1 - Preiß, C. A1 - Kayser, Peter A1 - Pack, O. A1 - Temiz Artmann, Aysegül T1 - Ureplace: development of a bioreactor for in vitro culturing of cell seeded tubular vessels on collagen scaffolds N2 - The demand of replacements for inoperable organs exceeds the amount of available organ transplants. Therefore, tissue engineering developed as a multidisciplinary field of research for autologous in-vitro organs. Such three dimensional tissue constructs request the application of a bioreactor. The UREPLACE bioreactor is used to grow cells on tubular collagen scaffolds OPTIMAIX Sponge 1 with a maximal length of 7 cm, in order to culture in vitro an adequate ureter replacement. With a rotating unit, (urothelial) cells can be placed homogeneously on the inner scaffold surface. Furthermore, a stimulation is combined with this bioreactor resulting in an orientation of muscle cells. These culturing methods request a precise control of several parameters and actuators. A combination of a LabBox and the suitable software LabVision is used to set and conduct parameters like rotation angles, velocities, pressures and other important cell culture values. The bioreactor was tested waterproof successfully. Furthermore, the temperature controlling was adjusted to 37 °C and the CO2 - concentration regulated to 5 %. Additionally, the pH step responses of several substances showed a perfect functioning of the designed flow chamber. All used software was tested and remained stable for several days. KW - Tissue Engineering KW - Bioreaktor KW - Organkultur KW - Harnleiter Y1 - 2011 ER - TY - THES A1 - Seifarth, Volker T1 - Ureteral tissue engineering : development of a bioreactor system and subsequent characterization of the generated biohybrids Y1 - 2015 N1 - Duisburg, Essen, Universität Duisburg-Essen, Diss., 2015 PB - Universitätsbibliothek Duisburg-Essen CY - Duisburg ; Essen ER - TY - JOUR A1 - Seidova, Seid-Fatima A1 - Kotliar, Konstantin A1 - Foerger, Frauke A1 - Klopfer, Matthias A1 - Lanzl, Ines T1 - Functional retinal changes in Gaucher disease JF - Documenta Ophthalmologica Y1 - 2009 SN - 1573-2622 VL - 118 IS - 2 SP - 151 EP - 154 PB - Springer CY - Berlin ER - TY - JOUR A1 - Schütz, S. A1 - Weißbecker, G. A1 - Schroth, P. A1 - Schöning, Michael Josef T1 - Linkage of inanimate structures to biological systems – smart materials in biological micro- nanosystems JF - Smart materials : proceedings of the 1st Caesarium, Bonn, November 17 - 19, 1999 / Karl-Heinz Hoffmann ed. Y1 - 2001 SN - 3-540-67957-X SP - 149 EP - 157 PB - Springer CY - Berlin [u.a.] ER - TY - JOUR A1 - Schütz, S. A1 - Weißbecker, B. A1 - Hummel, Hans E. A1 - Schöning, Michael Josef A1 - Riemer, A. A1 - Kordos, P. A1 - Lüth, H. T1 - Field effect transistor-insect antenna junction JF - Naturwissenschaften Y1 - 1997 SN - 1432-1904 VL - 84 SP - 86 EP - 88 ER - TY - JOUR A1 - Schütz, S. A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Weißbecker, B. A1 - Kordos, P. A1 - Lüth, H. A1 - Hummel, Hans E. T1 - An insectbased BioFET as a bioelectronic nose JF - Sensors and Actuators B. 65 (2000), H. 1-3 Y1 - 2000 SN - 0925-4005 SP - 291 EP - 295 ER - TY - JOUR A1 - Schütz, S. A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Weißbecker, B. A1 - Kordos, P. A1 - Lüth, H. A1 - Hummel, Hans E. T1 - An insectbased BioFET as a bioelectronic nose JF - Proceedings of the Seventh International Meeting on Chemical Sensors : 27 - 30 July, 1998, Beijing, P. R. China / ed. Zhi-Gang Zhou Y1 - 1998 N1 - International Meeting on Chemical Sensors ; (7, 1998, Beijing) ; International Meeting on Chemical Sensors (IMCS) ; (7 : ; 1998.07.27-30 : ; Beijing) SP - 314 EP - 316 PB - Elsevier CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Schütz, S. A1 - Hummel, Hans E. A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Kordos, P. A1 - Lüth, H. A1 - Zimmermann, S. A1 - Schwarz, A. A1 - Kohl, C.-D. A1 - Koczan, D. T1 - Applications and perspectives of biosensors based on insect olfaction JF - Sensor 99 : proceedings / 9th International Fair and Conference for Sensors, Transducers & Systems, May 18 - 20, 1999, Exhibition Centre Nürnberg/Germany Y1 - 1999 N1 - Internationale Messe mit Kongreß für Sensoren, Meßaufnehmer & Systeme ; (9, 1999, Nürnberg) SP - 99 EP - 104 PB - AMA Service CY - Wunstorf ER - TY - JOUR A1 - Schütz, S. A1 - Czynski, J. A1 - Hummel, Hans E. A1 - Schöning, Michael Josef A1 - Schroth, P. A1 - Kordos, P. A1 - Lüth, H. T1 - Insect meets microelectronics: A BioFET as a first step to bioelectronic microsystems JF - Transducers '99 : proceedings of the Tenth International Conference on Solid-State Sensors and Actuators ; 7 - 10 June, 1999, Sendai, Japan / ed.: S. Middelhoek Y1 - 2000 N1 - International Conference on Solid State Sensors and Actuators <10, 1999, Sendai, Miyagi-ken> ; Transducers '99 ; (10 : ; 1999.06.07-10 : ; Sendai) SP - 1104 EP - 1107 PB - Elsevier CY - Amsterdam [u.a.] ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Weidenbrück, B. A1 - Thust, M. A1 - Kordos, P. A1 - Lüth, H. T1 - A silicon-based sensor array with capacitive EIS structures JF - Proceedings of the 11th European Conference on Solid-State Transducers / Eurosensors XI, September 21 - 24, 1997, Warsaw, Poland. [Organised by] Warsaw University of Technology. Vol 2. Y1 - 1997 SN - 83-908335-0-6 N1 - Eurosensors ; (11, 1997, Warszawa) ; Eurosensors - European Conference on Solid-State Transducers ; (11 : ; 1997.09.21-24 : ; Warsaw) SP - 871 EP - 874 PB - Sensor Lab Sp. CY - Warsaw ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Wang, Josepf A1 - Krause, Robin A1 - Block, Kirstin A1 - Musameh, Mustafa A1 - Mulchandani, Ashok A1 - Mulchandani, Priti A1 - Chen, Wilfred T1 - Dual amperometric-potentiometric biosensor detection system for monitoring organophosphorus neurotoxins JF - Analyica Chimica Acta. 469 (2002), H. 2 Y1 - 2002 SN - 0378-4304 SP - 197 EP - 203 ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Wang, J. A1 - Jacobs, M. A1 - Knobbe, D.-T. A1 - Muck, A. T1 - Amperometric PDMS-glass capillary electrophoresis-based biosensor microchip for catechol and dopamine detection JF - Technical digest of the 10th International Meeting on Chemical Sensors, July 11 - 14, 2004, Tsukuba, Japan / Japan Association of Chemical Sensors Y1 - 2004 N1 - Chemical sensors ; 20.2004 Suppl. B. IMCS ; (10, 2004, Tsukuba) ; International Meeting on Chemical Sensors ; (10 : ; 2004.07.11-14 : ; Tsukuba) SP - 566 EP - 567 PB - Japan Association of Chemical Sensors CY - Fukuoka ER - TY - JOUR A1 - Schöning, Michael Josef A1 - Wagner, Torsten A1 - Wang, C. A1 - Otto, R. A1 - Yoshinobu, T. T1 - Development of a handheld 16 channel pen-type LAPS for electrochemical sensing JF - Sensors and Actuators B. 108 (2005) Y1 - 2005 SN - 0925-4005 SP - 808 EP - 814 ER -