TY - JOUR A1 - Schreiber, Marc A1 - Barkschat, Kai A1 - Kraft, Bodo A1 - Zündorf, Albert T1 - Quick Pad Tagger : An Efficient Graphical User Interface for Building Annotated Corpora with Multiple Annotation Layers JF - Computer Science & Information Technology (CS & IT) Y1 - 2015 SN - 978-1-921987-32-8 U6 - http://dx.doi.org/10.5121/csit.2015.50413 SN - 2231 - 5403 VL - 5 IS - 4 SP - 131 EP - 143 PB - Academy & Industry Research Collaboration Center (AIRCC) ER - TY - CHAP A1 - Schreiber, Marc A1 - Barkschat, Kai A1 - Kraft, Bodo T1 - Using Continuous Integration to organize and monitor the annotation process of domain specific corpora T2 - 5th International Conference on Information and Communication Systems (ICICS) : 1-3 April 2014, Irbid, Jordanien Y1 - 2014 SN - 978-1-4799-3022-7 U6 - http://dx.doi.org/10.1109/IACS.2014.6841958 SP - 1 EP - 6 ER - TY - CHAP A1 - Schoutetens, Frederic A1 - Dachwald, Bernd A1 - Heiligers, Jeannette T1 - Optimisation of photon-sail trajectories in the alpha-centauri system using evolutionary neurocontrol T2 - 8th ICATT (International Conference on Astrodynamics Tools and Techniques) 23 - 25 June 2021, Virtual N2 - With the increased interest for interstellar exploration after the discovery of exoplanets and the proposal by Breakthrough Starshot, this paper investigates the optimisation of photon-sail trajectories in Alpha Centauri. The prime objective is to find the optimal steering strategy for a photonic sail to get captured around one of the stars after a minimum-time transfer from Earth. By extending the idea of the Breakthrough Starshot project with a deceleration phase upon arrival, the mission’s scientific yield will be increased. As a secondary objective, transfer trajectories between the stars and orbit-raising manoeuvres to explore the habitable zones of the stars are investigated. All trajectories are optimised for minimum time of flight using the trajectory optimisation software InTrance. Depending on the sail technology, interstellar travel times of 77.6-18,790 years can be achieved, which presents an average improvement of 30% with respect to previous work. Still, significant technological development is required to reach and be captured in the Alpha-Centauri system in less than a century. Therefore, a fly-through mission arguably remains the only option for a first exploratory mission to Alpha Centauri, but the enticing results obtained in this work provide perspective for future long-residence missions to our closest neighbouring star system. Y1 - 2021 N1 - 8th ICATT (International Conference on Astrodynamics Tools and Techniques) 23 - 25 June 2021, Virtual SP - 1 EP - 15 ER - TY - JOUR A1 - Schopp, Christoph A1 - Rohrbach, Felix A1 - Langer, Luc A1 - Heuermann, Holger T1 - Detection of welding wire length by active S11 measurement JF - IEEE Transactions on Plasma Science N2 - A novel method to determine the extruded length of a metallic wire for a directed energy deposition (DED) process using a microwave (MW) plasma jet with a straight-through wire feed is presented. The method is based on the relative comparison of the measured frequency response obtained by the large-signal scattering parameter (Hot-S) technique. In the practical working range, repeatability of less than 6% for a nonactive plasma and 9% for the active plasma state is found. Measurements are conducted with a focus on a simple solution to decrease the processing time and reduce the integration time of the process into the existing hardware. It is shown that monitoring a single frequency for magnitude and phase changes is sufficient to achieve good accuracy. A combination of different measurement values to determine the length is possible. The applicability to different diameter of the same material is shown as well as a contact detection of the wire and metallic substrate. KW - Circuit simulation KW - Hot S-parameter KW - Modeling KW - Plasma KW - Plasma diagnostics Y1 - 2024 U6 - http://dx.doi.org/10.1109/TPS.2024.3356659 SN - 0093-3813 (Print) SN - 1939-9375 (Online) IS - Early Access SP - 1 EP - 6 PB - IEEE ER - TY - CHAP A1 - Schopp, Christoph A1 - Nachtrodt, Frederik A1 - Heuermann, Holger A1 - Scherer, Ulrich W. A1 - Mostacci, Domiziano A1 - Finger, Torsten A1 - Tietsch, Wolfgang T1 - A novel 2.45 GHz/200 W Microwave Plasma Jet for High Temperature Applications above 3600 K T2 - Journal of Physics : Conference Series Y1 - 2012 SN - 1742-6596 VL - 406 IS - 012029 ER - TY - CHAP A1 - Schopp, Christoph A1 - Heuermann, Holger A1 - Marso, Michel T1 - Multiphysical Study of an Atmospheric Microwave Argon Plasma Jet T2 - IEEE Transactions on Plasma Science Y1 - 2017 U6 - http://dx.doi.org/10.1109/TPS.2017.2692735 SN - 1939-9375 VL - 45 IS - 6 SP - 932 EP - 937 PB - IEEE ER - TY - CHAP A1 - Schopp, Christoph A1 - Heuermann, Holger A1 - Holtrup, S. T1 - Investigation on efficacy optimization of RF-driven automotive D-lamps T2 - 44th European Microwave Conference (EuMC),2014, Rome Y1 - 2014 U6 - http://dx.doi.org/10.1109/EuMC.2014.6986645 SP - 1154 EP - 1157 ER - TY - CHAP A1 - Schopp, Christoph A1 - Heuermann, Holger T1 - Electrodeless low pressure lamp with bi-static matching at 2.45 GHz T2 - 2013 European Microwave Conference (EuMC) , Nuremberg Y1 - 2013 SN - 978-1-4799-0264-4 SP - 881 EP - 884 PB - IEEE CY - Piscataway, NJ ER - TY - JOUR A1 - Schopp, Christoph A1 - Doll, Timo A1 - Gräser, Ulrich A1 - Harzheim, Thomas A1 - Heuermann, Holger A1 - Kling, Rainer A1 - Marso, Michael T1 - Capacitively Coupled High-Pressure Lamp Using Coaxial Line Networks JF - IEEE Transactions on Microwave Theory and Techniques N2 - This paper describes the development of a capacitively coupled high-pressure lamp with input power between 20 and 43 W at 2.45 GHz, using a coaxial line network. Compared with other electrodeless lamp systems, no cavity has to be used and a reduction in the input power is achieved. Therefore, this lamp is an alternative to the halogen incandescent lamp for domestic lighting. To serve the demands of domestic lighting, the filling of the lamp is optimized over all other resulting requirements, such as high efficacy at low induced powers and fast startups. A workflow to develop RF-driven plasma applications is presented, which makes use of the hot S-parameter technique. Descriptions of the fitting process inside a circuit and FEM simulator are given. Results of the combined ignition and operation network from simulations and measurements are compared. An initial prototype is built and measurements of the lamp's lighting properties are presented along with an investigation of the efficacy optimizations using large signal amplitude modulation. With this lamp, an efficacy of 135 lmW -1 is achieved. Y1 - 2016 U6 - http://dx.doi.org/10.1109/TMTT.2016.2600326 SN - 0018-9480 VL - 64 IS - 10 SP - 3363 EP - 3368 PB - IEEE CY - New York, NY ER - TY - JOUR A1 - Schopp, Christoph A1 - Britun, Nikolay A1 - Vorac, Jan A1 - Synek, Petr A1 - Snyders, Rony A1 - Heuermann, Holger T1 - Thermal and Optical Study on the Frequency Dependence of an Atmospheric Microwave Argon Plasma Jet JF - IEEE Transactions on Plasma Science Y1 - 2019 SN - 1939-9375 VL - 47 IS - 7 SP - 3176 EP - 3181 PB - IEEE CY - New York ER - TY - CHAP A1 - Schopen, Oliver A1 - Shabani, Bahman A1 - Esch, Thomas A1 - Kemper, Hans A1 - Shah, Neel ED - Rahim, S.A. ED - As'arry, A. ED - Zuhri, M.Y.M. ED - Harmin, M.Y. ED - Rezali, K.A.M. ED - Hairuddin, A.A. T1 - Quantitative evaluation of health management designs for fuel cell systems in transport vehicles T2 - 2nd UNITED-SAIG International Conference Proceedings N2 - Focusing on transport vehicles, mainly with regard to aviation applications, this paper presents compilation and subsequent quantitative evaluation of methods aimed at building an optimum integrated health management solution for fuel cell systems. The methods are divided into two different main types and compiled in a related scheme. Furthermore, different methods are analysed and evaluated based on parameters specific to the aviation context of this study. Finally, the most suitable method for use in fuel cell health management systems is identified and its performance and suitability is quantified. KW - aviation application KW - health management systems KW - fuel cell systems Y1 - 2022 N1 - 2nd UNITED-SAIG International Conference, 23-24 May 2022, Putrajaya, Malaysia SP - 1 EP - 3 ER - TY - CHAP A1 - Schopen, Oliver A1 - Kemper, Hans A1 - Esch, Thomas T1 - Development of a comparison methodology and evaluation matrix for electrically driven compressors in ICE and FC T2 - Proceedings of the 1st UNITED – Southeast Asia Automotive Interest Group (SAIG) International Conference N2 - In addition to electromobility and alternative drive systems, a focus is set on electrically driven compressors (EDC), with a high potential for increasing the efficiency of internal combustion engines (ICE) and fuel cells [01]. The primary objective is to increase the ICE torque, provided independently of the ICE speed by compressing the intake air and consequently the ICE filling level supported by the compressor. For operation independent from the ICE speed, the EDC compressor is decoupled from the turbine by using an electric compressor motor (CM) instead of the turbine. ICE performances can be increased by the use of EDC where individual compressor parameters are adapted to the respective application area [02] [03]. This task contains great challenges, increased by demands with regard to pollutant reduction while maintaining constant performance and reduced fuel consumption. The FH-Aachen is equipped with an EDC test bench which enables EDC-investigations in various configurations and operating modes. Characteristic properties of different compressors can be determined, which build the basis for a comparison methodology. Subject of this project is the development of a comparison methodology for EDC with an associated evaluation method and a defined overall evaluation method. For the application of this comparison methodology, corresponding series of measurements are carried out on the EDC test bench using an appropriate test device. KW - electro mobility KW - fuel cell KW - internal combustion engine KW - electrically driven compressors Y1 - 2021 SN - 978-3-902103-94-9 N1 - 1st UNITED-SAIG International Conference, 21-22 APR 2021, Chulalongkorn University, Thailand SP - 45 EP - 46 PB - FH Joanneum CY - Graz ER - TY - JOUR A1 - Scholz, Christina A1 - Romagnoli, Daniele A1 - Dachwald, Bernd A1 - Theil, Stephan T1 - Performance analysis of an attitude control system for solar sails using sliding masses JF - Advances in Space Research Y1 - 2011 SN - 0273-1177 VL - 48 IS - 11 SP - 1822 EP - 1835 PB - Elsevier CY - Amsterdam ER - TY - JOUR A1 - Scholz, A. A1 - Ley, Wilfried A1 - Dachwald, Bernd A1 - Miau, J. J. A1 - Juang, J. C. T1 - Flight results of the COMPASS-1 picosatellite mission JF - Acta Astronautica. 67 (2010), H. 9-10 Y1 - 2010 SN - 0094-5765 SP - 1289 EP - 1298 ER - TY - CHAP A1 - Scholl, Ingrid A1 - Suder, Sebastian A1 - Schiffer, Stefan T1 - Direct Volume Rendering in Virtual Reality T2 - Bildverarbeitung für die Medizin 2018 Y1 - 2018 SN - 978-3-662-56537-7 U6 - http://dx.doi.org/10.1007/978-3-662-56537-7_79 SP - 297 EP - 302 PB - Springer Vieweg CY - Berlin ER - TY - JOUR A1 - Scholl, Ingrid A1 - Pelikan, Erich A1 - Repges, Rudolf A1 - Tolxdorff, Thomas T1 - Texture-based feature extraction using the Wavelet transform on x rays. JF - Medical Imaging 1996: Image Processing Y1 - 1996 N1 - Proceedings of SPIE 2710 SP - 668 EP - 678 ER - TY - JOUR A1 - Scholl, Ingrid A1 - Palm, Christoph A1 - Lehmann, Thomas A1 - Spitzer, Klaus T1 - Quantitative Farbmessung in laryngoskopischen Bildern. Palm, C; Scholl, I; Lehmann, TM; Spitzer, K. JF - Bildverarbeitung für die Medizin 1998. Hrsg.: Thomas Lehmann ... Y1 - 1998 SN - 3-540-63885-7 SP - 412 EP - 416 PB - Springer CY - Berlin ER - TY - CHAP A1 - Scholl, Ingrid A1 - Bartella, Alex A1 - Moluluo, Cem A1 - Ertural, Berat A1 - Laing, Frederic A1 - Suder, Sebastian T1 - MedicVR : Acceleration and Enhancement Techniques for Direct Volume Rendering in Virtual Reality T2 - Bildverarbeitung für die Medizin 2019 : Algorithmen – Systeme – Anwendungen Y1 - 2019 SN - 978-3-658-25326-4 U6 - http://dx.doi.org/10.1007/978-3-658-25326-4_32 SP - 152 EP - 157 PB - Springer Vieweg CY - Wiesbaden ER - TY - JOUR A1 - Scholl, Ingrid A1 - Aach, Til A1 - Deserno, Thomas M. A1 - Kuhlen, Torsten T1 - Challenges of medical image processing JF - Computer Science - Research and Development Y1 - 2011 SN - 1865-2042 VL - 26 IS - 1-2 SP - 5 EP - 13 PB - Springer CY - Berlin ER - TY - JOUR A1 - Scholl, Fabio A1 - Morais, Paulo A1 - Gabriel, Rayla A1 - Schöning, Michael Josef A1 - Siqueira, Jose Roberto, Jr. A1 - Caseli, Luciano T1 - Carbon nanotubes arranged as smart interfaces in lipid Langmuir-Blodgett films enhancing the enzymatic properties of penicillinase for biosensing applications JF - Applied Materials & Interfaces N2 - In this paper, carbon nanotubes (CNTs) were incorporated in penicillinase-phospholipid Langmuir and Langmuir–Blodgett (LB) films to enhance the enzyme catalytic properties. Adsorption of the penicillinase and CNTs at dimyristoylphosphatidic acid (DMPA) monolayers at the air–water interface was investigated by surface pressure–area isotherms, vibrational spectroscopy, and Brewster angle microscopy. The floating monolayers were transferred to solid supports through the LB technique, forming mixed DMPA-CNTs-PEN films, which were investigated by quartz crystal microbalance, vibrational spectroscopy, and atomic force microscopy. Enzyme activity was studied with UV–vis spectroscopy and the feasibility of the supramolecular device nanostructured as ultrathin films were essayed in a capacitive electrolyte–insulator–semiconductor (EIS) sensor device. The presence of CNTs in the enzyme–lipid LB film not only tuned the catalytic activity of penicillinase but also helped conserve its enzyme activity after weeks, showing increased values of activity. Viability as penicillin sensor was demonstrated with capacitance/voltage and constant capacitance measurements, exhibiting regular and distinctive output signals over all concentrations used in this work. These results may be related not only to the nanostructured system provided by the film, but also to the synergism between the compounds on the active layer, leading to a surface morphology that allowed a fast analyte diffusion because of an adequate molecular accommodation, which also preserved the penicillinase activity. This work therefore demonstrates the feasibility of employing LB films composed of lipids, CNTs, and enzymes as EIS devices for biosensing applications. Y1 - 2017 U6 - http://dx.doi.org/10.1021/acsami.7b08095 SN - 1944-8252 VL - 9 IS - 36 SP - 31054 EP - 31066 PB - ACS CY - Washington ER -